Home

Oplink Security TripleShield Hardware Manual

image

Contents

1. 2 Log in to your router s account Check your user manual or documentation if you do not know the log in credentials 3 Make sure you are in the Setup category select Enable DHCP and enter the address range from 192 168 1 100 to 192 168 1 199 Oplink Communications Inc 26 V 2 17t1 LiNK FCC Statement 1 Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures L Reorient or relocate the receiving antenna Ll Increase the separation between the equipment and receiver L Connect the equipment into an outlet on a circ
2. V 2 17t1 mi Security Oplink Security TripleShield Hardware User Manual Oplink Communications Inc Oplink Communications Inc 1 V 2 17t1 Contents T SOC UE Ny E AL cr m 3 Assemble OPU Station And Connect To Router 5 Set Up And Power Up IP Camera 1eeeeee sense eene eene nn nante nna nnn naa n nna nnuns 7 Place Sensors And Power Up Siren eene eer ennnn nnne 10 a Install the Door Window Sensor eee enne nnnnnnnnnnen nnne 10 DI MOUGN SENSO O O O ia ahi niania 15 CA SINS 10 O T O O O 17 d Sensor Range Extender PM O Ei 18 hune E E E E E vscsuetenreneciie 19 OPU e E 19 Bis Wi EU T A 20 Bd P 20 SONNY Gre T C 21 Sal 6 rr 21 Door Window Sensor ccccccecesesecceeesesneccccecsessccceceessnccecesecneececeseesnaececesesateeeensneeeeeeeeesaaeees 22 MOTON l pe der mene en eee tee ee E E T eee 23 s AEE AN E A E TE ee 24 Remote Control mm 25 APPENA B aii E EE 26 FCC State m eDi siirre EEEE E SEEE EAren NEARER AENEAN 27 Oplink Communications Inc 2 V 2 17t1 LiNK mi Security At A Glance Product Name Function Provide wireless access and control OPU Oplink Processing Unit function of mi Security
3. 433 92MHz 150KHz Modulation ASK Transmit Power 16dBm Manufacture s test condition Detection Type Magnetic separation trigger function Magnet Sensor Gap Activated 25mm Reference Power source CR123A 3V Standby Current 3uA Operating Current lt 15mA Battery Low Level Indicator 2 1 V 2 35V Low Battery Alarm Mode Low battery alarms only when another sensor alarm is triggered Unpick Detection Tamper switch wireless alarm M Motion Sensor Model PIR1301 menn Operating Temperature 14 F to 122 F 10 C to 50 C Frequency 433 92 MHz 150KHz L B Transmit Power gt 16dBm Manufacture s test condition niim Modulation ASK Oplink Communications Inc 23 V 2 17t1 M Siren Power Source CR123A 3V Standby Current 25uA PIR Trigger Current lt 15mA Power Consumption 1 year Triggered twice a day Battery Low Level Indicator 2 1 V 2 35V Low Battery Alarm Mode Low battery alarms only when sensor alarm is triggered PIR Trigger Alarm Once Motion Sensor alarms it will start to count 3 minutes and start over again if any movement is detected within this period The next alarm will be triggered only when no movement is detected within the 3 minutes Unpick Detection Tamper switch wireless alarm Model SRN1300 Operating Temperature 32 F to 113 F 0 C to 40 C Device Type Wireless Indoor Siren RF Receiver Frequency 433 92 MHz 0 125MHz Sensitivity 110dbm Mo
4. IV and Business Package ad e Smart setup wizard e Wireless security technology e Support Oplink cloud server e Apply to doors windows etc e Send off instant intrusion alerts e Easy to install no wiring required e Auto add on to any Oplink security system e Battery included Oplink Communications Inc 12 V 2 17t1 LiNK Sensor DWM1301 Installation To install the sensors 1 Install the battery 2 Attach the double sided tape onto the backs of the units 3 Door Window a On your door i After selecting a location on the door preferably on the edge of the door away from the hinges the large unit of the sensor should be placed on the immovable frame of the door ii Place the small unit on the movable door with the small unit aligned near the top half of the large unit and not exceeding the recommended width of a pencil or a quarter of an inch between the sensors for best performance b On your window i After selecting a location on the window the large unit of the sensor should be placed on the immovable window frame Oplink Communications Inc 13 V 2 17t1 LiNK ii Place the small unit on the movable window with the small unit aligned near the top half of the large unit and not exceeding the recommended width of a pencil or a quarter of an inch between the sensors for best performance 4 When you open and close the doors and windows the two parts should separate when opened and then c
5. 2 0 Performance Read 20MB sec above Write 4 5MB sec above Operating Voltage 4 5 5 5VDC System Windows Mac OS Operating Temperature 32 F to 113 F 0 C to 45 C Storage Temperature 4 F to 158 F 20 Cto 70 C Model IPC1200 Dimensions 73 L x 26 W x 95mm H Operating Temperature 32 F to 113 F 0 C to 45 C Video compression MJPEG Image resolution 640 x 480 Storage Temperature 5 F to 140 F 15 C to 60 C Network Protocols DHCP Auto IP Address Network Interface 1 Ethernet 10 100BaseT RJ45 LAN Oplink Communications Inc 21 V 2 17t1 LiNK connection Wireless interface EEE 802 11 b g n WPA2 PSK Power Adapter 5V 1A gt Door Window Sensor Model DWM1300 Operating Temperature 32 F to 113 F 0 C to 45 C Frequency 433 80MHz 434 1 MHz Modulation ASK Transmit Power gt 51dBm Manufacture s test condition Detection Type Magnetic separation trigger function Magnet Sensor Gap Activated 11mm Reference Power source 1 5V 2pcs AAA Lithium and Iron Disulfide battery Standby Current 10uA 3 3VDC Operating Current 18mA 3 3VDC Battery Low Level Indicator 2 2V 2 4V Low Battery Alarm Mode Low battery alarms only when another sensor alarm is triggered Unpick Detection Tamper switch wireless alarm Oplink Communications Inc 22 V 2 17t1 LiNK Model DWM1301 Operating Temperature 32 F to 113 F 0 C to 45 C 42 Frequency
6. system Transmit sensor data and control signal Surveillance camera with built in IP Camera microphone Detects and alerts user of movement Motion Sensor within the vicinity Oplink Communications Inc 3 V 2 17t1 Door Window Sensor Remote Control with Panic Button 4 port USB Hub 16G Flash Drive Oplink Communications Inc Use on doors windows etc Siren integrated with Smart wireless security technology Arm Disarm system and emergency hotline Additional USB ports to connect devices to OPU Extra data storage for video recordings V 2 17t1 LiNK Assemble OPU Station And Connect To Router Contents A HE C A OPU U i N B Dongle CON LINK p C Ethernet Cable nl D Power Adapter E 16G Flash Drive F USB Hub B D Overview Features e Smart setup wizard e Bridge the communication for all Oplink smart devices e Provide wireless access and E O F control function of mi Security system MNIIdo wi e OPU allows for system OP recovery X e Transmit sensor data and control signal e Support Oplink cloud server Wireless Features e Support IEEE 802 11 b g n standards e Wired and Wireless Network Oplink Communications Inc 5 V 2 17t1 LiNK Support e Security Support WPA2 PSK encryption OPU and Dongle Installation with USB Hub and Flash Drive a Plug the Dongle and the Fl
7. wall at the desired location c Make sure the motion sensor is placed at an angle with the least amount of obstruction for best coverage Do not aim the detector at a staircase which a pet has access to Do not mount the detector near furniture or objects higher than 4 feet tall which a pet may climb onto such as a couch within 6 feet of the detector Oplink Communications Inc 16 V 2 17t1 LiNK c Siren Contents A Wireless Siren With Power Adapter B Mounting Screws And Dry Wall Anchors Overview Features e Smart setup wizard e Wireless security technology e Support Oplink cloud server e Alarm for 60 seconds upon receiving SIREN ON order stops immediately upon receiving SIREN OFF order Siren Installation Set up and wall mount the Wireless Siren Step 1 Use double sided tape or screws to mount at desired locations Step 2 Connect siren to nearest power outlet Step 3 Place the siren within effective range of the OPU Oplink Communications Inc 17 Contents A Sensor Range Extender B Power Adapter Overview Features e Smart setup wizard e Wireless security technology e Support Oplink cloud server e Transfer legal 433MHz signal Installation of Sensor Range Extender Adding the Sensor Range Extender Optional Step 1 Plug the sensor range extender into the adaptor Step 2 Plug the combination into a power outlet Step 3 Place the sensor range extender between OPU and se
8. ash Drive into the Hub Note The Flash Drive does not support hot swapping nor hot plugging The OPU must be powered down before adding or removing the Flash Drive to or from the Hub b Plug the Hub into the OPU c Connect the OPU to the home router using the provided Ethernet cable d Plug power adapter to the OPU and an outlet e Enable DHCP setup see Appendix B for DHCP setting of router Most routers have their DHCP setting set to Enabled by default Oplink Communications Inc 6 V 2 17t1 Set Up And Power Up IP Camera Contents O 9 W P Camera Bracket Power Adapter Mounting Screws And Dry Wall Anchors Overview Features Smart setup wizard High guality video Built in antenna and microphone Support Oplink cloud server Day night vision Records automatically when alarms are triggered Remote monitoring from smartphone or tablet Wireless Features Oplink Communications Inc Supports IEEE 802 11 b g n standards Wired and Wireless Network Support Security Support WPA2 PSK encryption V 2 17t1 LiNK Camera Installation Set Up the Camera a Place the camera within range of a power outlet and connect power cord to the outlet b Connect power adapter to the camera Mounting the Camera Optional Note The camera can also be placed on a table using the bracket provided We recommend you placing the camera on a counte
9. ation on the door preferably on the edge of the door away from the hinges the large unit of the sensor should be placed on the immovable frame of the door ii Place the small unit on the movable door with the small arrows on each unit aligned and not exceeding the recommended width of a pencil or a quarter of an inch between the sensors for best performance b On your window i After selecting a location on the window the large unit of the sensor should be placed on the immovable window frame ii Place the small unit on the movable window with the small arrows on each unit aligned and not exceeding the recommended width of a pencil or a quarter of an inch between the sensors for best performance 4 When you open and close the doors and windows the two parts should separate when opened and then come back together when closed Oplink Communications Inc 11 V 2 17t1 LiNK Note If your door or window does not allow you to properly place the large unit of the sensor on the frame it is acceptable to place the smaller unit of the sensor on the frame to make the placing easier This is an acceptable approach to sensor placement although it should only be used when necessary Warning Do not dispose of electrical appliances as unsorted municipal waste Use separate collection facilities Contact your local government for information regarding the collection systems available DWM1301 Overview Features For Home Package II
10. dulation ASK Power Source Main Power AC Adaptor American Standard Backup Battery Alkaline battery AAA size 3pcs Standby Mode Current lt 12mA average 04 5V Alarm Mode Current lt 300MA 4 5V Oplink Communications Inc 24 V 2 17t1 LiNK M Remote Control Alarm Sound Level gt 110dB 30cm on desktop 4 5V Power Model RMC 1300 Power A23 12V Battery Power Consumption gt 1year Triggered twice a day Button ARM ARM ON mode OFF ARM OFF mode Hotline Panic Button Operating Environment 32 F to 113 F 0 C to 40 C Storage Temperature 4 F to 159 F 20 C to 65 C RF Frequency 433 92 MHz 0 13MHz Modulation ASK Transmit Power 55dBm 4dBm Oplink Communications Inc 25 OP V2 17t1 Appendix B DHCP Dynamic Host Configuration Protocol setting of router Settings Private Network If you change the IP address range you must renew the DHCP lease on all devices on the network 192 168 1 0 255 255 255 0 default 172 16 0 0 255 255 0 0 10 0 0 0 255 255 0 0 Configure manually Router Address Subnet Mask C Enable DHCP Sg EE mi First DHCP Address 192 168 1 100 Last DHCP Address 192 168 1 199 Default DHCP Pool Fig 1 DHCP Setting of Router Example of Router 2wire 2701HG B 1 Open a browser and enter your IP address such as 192 168 X X You can find this address on the back of the router
11. nsors Adjust the distance to make sure it bridges up the wireless devices so that they would seamlessly roam across to the OPU Oplink Communications Inc 18 V 2 17t1 LiNK Appendix A Specifications M OPU Model OPU1120 cx f Dimensions 56 mm x 56 mm x 17 3 mm S gt 7 Operating Temperature 32 F to 113 F 0 C to 40 C Frequency 2 4 2 4835 GHz Transmit Speed 150Mbps Max Channel 13 TX Power 14dbm 15dbm Max Storage Temperature 40 F to 158 F 40 C to 70 C Network Protocols DHCP Auto IP Address Network Interface One 10 100Mbps LAN WAN Interchangeable Port IEEE 802 3 IEEE 802 3u Wireless interface IEEE 802 11 b g n WPA2 PSK Power Adapter 5V 1A Oplink Communications Inc 19 V 2 17t1 LiNK X Dongle Model DGL1130 Dimensions 83 mm x 27 mm x 9 3 mm Operating Temperature 32 F to 113 F 0 C to 45 C Power Rating DC5V 50mA Frequency 433 92MHz Transceiver Mode Half duplex Modulate Type ASK Sensitivity 110dbm Support hot swapping M USBHub Model HUB1112 Dimensions 50mm x 50 mm x 22 mm E Weight 36g M Capacity 4 USB ports Communication Standard USB 2 0 Performance Support 480Mbps high speed Operating Voltage 4 5 5 5VDC System Windows Mac OS Oplink Communications Inc 20 V 2 17t1 M Flash Drive M Camera Model UST1100 Dimensions 34 6 mm x 12 2 mm x 4 5 mm Weight 4 6g Capacity 16G Communication Standard USB
12. ome back together when closed Note If your door or window does not allow you to properly place the large unit of the sensor on the frame it is acceptable to place the smaller unit of the sensor on the frame to make the placing easier This is an acceptable approach to sensor placement although it should only be used when necessary Warning Do not dispose of electrical appliances as unsorted municipal waste Use separate collection facilities Contact your local government for information regarding the collection systems available Oplink Communications Inc 14 V 2 17t1 LiNK b Motion Sensor Contents A Motion Sensor B Battery C Double sided Tape Overview Features e Smart setup wizard e Wireless security technology e Support Oplink cloud server e Detects motion up to 120 degree 10 40 feet e Passive Infrared Pet immune e Battery included Motion Sensor Installation Oplink Communications Inc 15 V 2 17t1 LiNK Set up and wall mount the motion sensor Step 1 Insert Battery a Lift top tab on cover to release and remove cover b Insert the battery noting the polarity CR123A and replace the cover onto the sensor Step 2 Install Motion Sensor a Place the motion sensor appropriately to ensure maximum coverage of a monitored area The motion sensor monitors any movement up to 35 feet and should not be placed higher than 7 feet from the floor b Use double sided tape to mount on the
13. rtop giving it a clear line of sight Infrared night vision makes it easy to monitor at night Step 1 Install camera attachment base a At the desired camera mounting location secure the camera attachment base to the wall using the provided screws b Make use of the provided screw anchors if necessary Oplink Communications Inc 8 V 2 17t1 Step 2 Mount the camera a Screw camera onto attachment base b Secure camera using attachment base nut Step 3 Complete the camera s mount a Make sure the camera is firmly fixed on the wall b Adjust the camera to the preferred position Oplink Communications Inc V 2 17t1 Place Sensors And Power Up Siren a Install the Door Window Sensor Contents A Sensor Kit 2 contacts 1 large unit and 1 small unit B Batteries C Double sided Tape DWM1300 Overview Features for Home Package e Smart setup wizard e Wireless security technology e Support Oplink cloud server e Apply to doors windows etc e Send off instant intrusion alerts e Easy to install no wiring required e Auto add on to any Oplink security system e Batteries included Oplink Communications Inc 10 V 2 17t1 LiNK Sensor DWM1300 Installation To install the sensors 1 Install the batteries 2 Attach the double sided tape onto the backs of the units 3 Door Window a On your door i After selecting a loc
14. uit different from that to which the receiver is connected O Consult the dealer or an experienced radio TV technician for help 2 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 3 Shielded cables must be used with this unit to ensure compliance with the Class B FCC limits Oplink Communications Inc 27

Download Pdf Manuals

image

Related Search

Related Contents

New Solution For Encoding Embroidery Machine User's Manual  Intel Chipper 945GC User's Manual  l`explication de texte  GBC IB387166 binding cover  Deutsch FCC-KONFORMITÄTSERKLÄRUNG  Addendum to the Assembly and Operating Instructions – Planetary  MANUAL DE INSTRUCCIONES  Rockford Fosgate PUNCH250 User's Manual  Manual de Usuario del Sistema de Registro y Control de  CBR 900 RR 2000 - Remoto Retífica - (11) 2956  

Copyright © All rights reserved.
Failed to retrieve file