Home
AQ150 - General Tools And Instruments
Contents
1. Displays ambient or remote INT or EXT temperature Tracks MAX and MIN temperatures High and low temperature alarms for remote circuit C F button Backlit LCD and detachable cable of remote probe Foldaway stand and magnets on back of display unit e Includes battery and mounting hardware CE approved WHAT S IN THE BLISTER PACK The thermometer comes in a blister pack along with e A remote probe at the end of a detachable cable A suction cup for mounting the probe inside an aquarium or on a window A plastic bracket and screw for attaching the probe to wood e Two Velcro strips for mounting the display unit 1 preinstalled CR2032 battery with an activation tab This user s manual PRODUCT OVERVIEW Fig 1 shows the LCD and controls on the front of the AQ150 Fig 2 shows the key areas and components on the back of the unit Fig 1 The controls and indicators EN 6665 on the front of the AQ150 1 LCD Display shown indicates that the current real time temperature sensed by the remote EXT probe is 82 2 F 2 Max Min button Switches display out of real time mode to show maximum and minimum temperatures recorded since the unit s battery was installed or its memory was reset 3 Ext Int button Toggles display between internal and external temperature sensors 4 button Used to arm and disarm alarm and set high and low temperature alarm limits 5 button When pressed and held
2. heating table or window To attach the probe to a wooden outside window frame or apron 1 Slide the probe into the channel of the supplied black plastic bracket Push the probe until its tip reaches the end of the channel 2 Using the supplied Phillips head wood screw secure the bracket to the frame or apron OPERATING INSTRUCTIONS DISPLAYING REAL TIME TEMPERATURE To display the ambient temperature at the display unit press the Ext Int button until INT appears at the right of the readout To display the temperature sensed by the probe press the Ext Int button until EXT replaces INT DISPLAYING MAX AND MIN TEMPERATURES Pressing the Max Min button briefly for less than 1 second cycles through three readings maximum minimum and real time temperatures After the unit is activated the initial readout is the real time EXT temperature Press the Max Min button once and the display will switch to the highest maximum temperature recorded since the unit s battery was installed or since the memory was reset The term MAX will appear flashing at the left of the display Press the Max Min button again and the display will switch to the lowest minimum temperature recorded since the unit s battery was installed or since the memory was reset The term MIN will appear flashing at the left of the display Press the Max Min button a third time and the display will return to showing the real time INT or EXT temperature To reset the
3. IN OUT THERMOMETER WITH WATERPROOF PROBE USER S MANUAL MaxMin Multi Purpose Digital Thermometer AQ150 Please read this manual carefully and thoroughly before using this product TABLE OF CONTENTS Introduction 2 iiooiue rr tree Ih eee eee een eee 3 CALLIDA 4 Whats In the Blister Pack 00 ccc cece ese e cece eee eee RH e 4 Product 2 vcre eatin 5 6 Setup Instructions ccc cc cece cece eee eee m mmm 6 8 Activate the Thermometer 6 7 Choose a Temperature Unit eee eee n n n n n 7 Mount the Display Unit cell Let Ier n 7 8 Extend and Secure the Probe cccccceceeeeeeeeneseeeeeeneseenees 8 Operating Instr ctions senem imeem cm em fcn ne fen 9 11 Displaying Real time Temperature 9 Displaying MAX and MIN Temperatures 9 Setting High and Low Temperature Alarms 10 11 E 12 Maintenance Tips 13 Warranty Information 2 232221 2 0 1 0l orerar c xv ew cia wei 13 Return for Repair Policy scence eee IH HII 14 INTRODUCTION Thank you for purchasing General Tools amp Instruments AQ150 In Out Thermometer with Waterproof Probe Please read this user s manual car
4. Max Min memory press the Max Min button and hold it for at least 1 second SETTING HIGH AND LOW TEMPERATURE ALARMS Temperature alarms can only be set for the sensor in the external probe You cannot set alarms with the display unit mounted on a wall or frame because setting alarm levels requires access to the C F button on the back of the unit Before proceeding detach the unit by pulling it off the metal frame or separating the Velcro mounting strips 10 1 To set either or both alarms begin by pressing the button and holding it for 3 seconds This will cause the display to begin flashing a value along with the non flashing terms HIGH and EXT The term AL will also appear not flashing in the lower left corner You now have 1 minute to set the high temperature alarm limit at any level within the remote probe s range of 58 to 158 F 50 to 70 C by following Step 2 If you do not wish to set the high temperature alarm skip ahead to Step 3 below 2 To set the high temperature alarm limit hold the unit in one hand in front of your face With your other hand reach behind the unit and begin pressing the C F button Each press of the button increases the alarm temperature level as shown on the display by 1 8 with the display in F mode and by 1 with the display in C mode To speed up the process by increasing the temperature in multiple steps press and hold the C F button When the desired high temperat
5. efully and thoroughly before using the product The AQ150 has two separate temperature sensors one inside the display unit and the other inside a remote probe at the end of a 10 ft 3m long detachable cable The remote circuit can be configured to sound an alarm when the temperature it senses rises above or falls below a set limit This technology makes the AQ150 suitable for three different kinds of service Maintaining the water temperature of an aquarium In this application the display unit is magnetically attached to the frame of the aquarium and the remote probe is attached by suction cup to the inside of a glass wall below the water level The high and low alarms would both be set to keep the water temperature within a band that is healthy for fish Monitoring food temperature The dual alarms make it possible to track the temperature of a refrigerated case or heating table Magnets on the back of the display unit could be used to attach it to a metal part of the case or table The high temperature alarm would be used to guarantee that cold beverages and cold or frozen food remain that way Use of the low temperature alarm would ensure that hot food remains above a certain temperature keeping it safe to eat e Comparing indoor and outdoor temperature The cable of the remote probe is thin enough to fit under a window A front panel switch lets you toggle the display between INT interior and EXT exterior measurements KEY FEATURES
6. g 2 Callout 7 by placing your fingertip in the recess adjacent to the Velcro mounting area To attach the unit to the metal frame of an aquarium refrigerated case or heating table use the two magnets on the top edge of the back of the case To attach the unit to a wall or any non metal surface 1 Remove the two Velcro strips from the mounting hardware bag Do not separate them 2 Remove the paper backing from one strip and press its exposed sticky side into the unit s recessed rectangular mounting area Fig 2 Callout 8 3 Remove the paper backing from the other strip 4 Press the unit against the wall at the desired position To detach the unit to change the battery change the temperature unit or reset the high and or low alarm limits grab it and pull until the two Velcro strips separate EXTEND AND SECURE THE PROBE Remove the twist tie keeping the probe cable in a bundle Extend the probe cable to the desired length To install the remote probe in an aquarium 1 Slide the probe tip through the hole in the base of the suction cup 2 Press the suction cup firmly against the glass inside the aquarium about 4 in 100mm below water level To attach the probe to the inside of a refrigerated case or heating table or to the outside of a window 1 Slide the probe tip through the hole in the base of the suction cup 2 Moisten the inside of the suction cup and press it firmly against the inside frame or glass of the refrigerated case
7. m from sounding press any button SPECIFICATIONS Ambient Temperature Range 14 to 122 F 10 to 50 C Remote Temperature Range 58 to 158 F 50 to 70 C Measurement Accuracy 1 F 0 5 C from 4 to 122 F 20 to 50 C 1 8 F 1 C outside this range Display Resolution 0 1 C or F Sampling Period 10 seconds Probe Cord Length 10 ft 3m Display Size 1 88 x 0 82 in 48 x 21mm Digit Height 5 8 in 16mm Dimensions 2 9 x 2 1 x 0 7 in 73 x 52 x 18mm Weight 3 76 02 106g Power Source 1 CR2032 battery included 12 MAINTENANCE TIPS Although the sensor probe and cable are waterproof the display unit is NOT waterproof Do not install the display unit outdoors To clean the display unit wipe it gently with a dry or damp cloth Avoid using chemical cleaners To replace the battery follow the instructions at the top of p 7 WARRANTY INFORMATION General Tools amp Instruments General s AQ150 In Out Thermometer with Waterproof Probe is warranted to the original purchaser to be free from defects in material and workmanship for a period of one year Subject to certain restrictions General will repair or replace this instrument if after examination the company determines it to be defective in material or workmanship This limited warranty does not apply to damages that General determines to be from an attempted repair by non autho
8. ols com www generaltools com AQ150 User s Manual Specifications subject to change without notice 2012 GENERAL TOOLS amp INSTRUMENTS NOTICE WE ARE NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS MAN AQ150 9 25 12
9. rized personnel or misuse alterations normal wear and tear or accidental damage The defective unit must be returned to General Tools amp Instruments or to a General authorized service center freight prepaid and insured Acceptance of the exclusive repair and replacement remedies described herein is a condition of the contract for purchase of this product In no event shall General be liable for any incidental special consequential or punitive damages or for any cost attorneys fees expenses or losses alleged to be a consequence of any damage due to failure of or defect in any product including but not limited to any claims for loss of profits RETURN FOR REPAIR POLICY Every effort has been made to provide you with a reliable product of superior quality However in the event your instrument requires repair please contact our Customer Service to obtain an RGA Return Goods Authorization number before forwarding the unit via prepaid freight to the attention of our at this address General Tools amp Instruments 80 White Street New York NY 10013 212 431 6100 Remember to include a copy of your proof of purchase your return address and your phone number and or e mail address 14 NOTES Specialty Tools amp Instruments GENERAL TOOLS amp INSTRUMENTS 80 White Street New York NY 10013 3567 PHONE 212 431 6100 FAX 212 431 6499 TOLL FREE 800 697 8665 e mail sales generalto
10. turns display backlight on When released turns backlight off 6 Remote temperature sensing probe at the end of a detachable 10 ft 3m long cable Fig 2 The back of the AQ150 7 Foldaway stand for table or desktop mounting 8 Display unit Velcro mounting area 9 Mounting magnets 10 C F button Used to select displayed temperature unit and set high and low temperature alarm limits 11 Alarm speaker 12 Battery compartment SETUP INSTRUCTIONS ACTIVATE THE THERMOMETER If you are reading this you have already removed the unit the detachable probe the suction cup and the plastic bag of mounting hardware from the bubble wrap bag At this time DO NOT remove the twist tie keeping the 10 ft probe cable in a neat bundle 6 To activate the thermometer open the battery compartment in the back of the unit Fig 2 Callout 12 by lifting the left side of the hinged door with your fingertip Remove the battery activation tab The beeper will sound quickly four times Discard the tab and swing the battery compartment cover shut CHOOSE A TEMPERATURE UNIT Before proceeding remove the protective plastic film covering the display Then turn the unit over and press the red F button Fig 2 Callout 10 to select a Celsius C or Fahrenheit F temperature unit C is the default setting MOUNT THE DISPLAY UNIT To leave the unit free to move on a horizontal surface lift the foldaway stand on the back of the unit Fi
11. ure alarm level is displayed press the button to store the setting The beeper will sound once and the display will begin to flash a value along with the terms LOW and EXT You now have 1 minute to set the low temperature alarm level at any value within the remote probe s range of 58 to 158 F 50 to 70 C If you do not wish to set the low temperature alarm press the button again and skip ahead to Step 4 on next page 3 To set the low temperature alarm limit follow the instructions in Step 2 on previous page subtituting low for high and decreases decreasing for increases increasing 4 When the desired low and or high temperature alarm level s is are displayed press the button to store the setting s Once you have stored the high and or low alarm temperature level s the display will stop flashing and resume showing the Int or Ext temperature it was showing when the alarm setting process began However the term AL will remain in the lower left corner Whenever the display is not flashing the button serves as the vehicle for arming and disarming the alarms If AL appears on the display any alarms are armed If it does not any alarms are disarmed Note If you set a high alarm limit that is below the real time Ext temperature the alarm will sound within 10 seconds of storing the setting The alarm will also sound if you set a low alarm limit that is above the real time Ext temperature To stop the alar
Download Pdf Manuals
Related Search
Related Contents
Dell Precision 6T337 User's Manual Informer Compact Series LINE-INTERACTIVE Belkin MicroCharge + ChargeSync army boxing army boxing association association aide memoire Untitled Smeg FAB5RUJ refrigerator WLAN Measurements Imagerie en 3 dimensions: l`holographie 10ZiG Technology 8848v Keyboard Assembly 73/88 Owner's manual Copyright © All rights reserved.