Home
TEKTRONIX DPO4104B Datasheet
Contents
1. MSO4000B DPO4000B Series www tektronix com 19 Data Sheet www tektronix com Contact Tektronix ASEAN Australasia 65 6356 3900 Austria 00800 2255 4835 Balkans Israel South Africa and other ISE Countries 41 52 675 3777 Belgium 00800 2255 4835 Brazil 55 11 3759 7600 Canada 1 800 833 9200 Central East Europe Ukraine and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 00800 2255 4835 Germany 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835 Japan 81 3 6714 3010 Luxembourg 41 52 675 3777 Mexico Central South America amp Caribbean 52 56 04 50 90 Middle East Asia and North Africa 41 52 675 3777 The Netherlands 00800 2255 4835 Norway 800 16098 People s Republic of China 400 820 5835 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia amp CIS 7 495 7484900 South Africa 41 52 675 3777 Spain 00800 2255 4835 Sweden 00800 2255 4835 Switzerland 00800 2255 4835 Taiwan 886 2 2722 9622 United Kingdom amp Ireland 00800 2255 4835 USA 1 800 833 9200 European toll free number If not accessible call 41 52 675 3777 Updated 25 May 2010 For Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on t
2. Service Options 2 Option Opt CA1 C3 C5 D1 D3 D5 R5 Description North America Universal Euro United Kingdom Australia Switzerland Japan China India No power cord or AC adapter Description English manual French manual Italian manual German manual Spanish manual Japanese manual Portuguese manual Simplified Chinese manual Traditional Chinese manual Korean manual Russian manual No manual Description Provides a single calibration event or coverage for the designated calibration interval whichever comes first Opt Opt Opt Opt Opt Opt 2 Probes and accessories are not covered by the oscilloscope warranty and service offerings Refer to the Calibration Service 3 years Calibration Service 5 years Calibration Data Report Calibration Data Report 3 years with Opt C3 Calibration Data Report 5 Years with Opt C5 Repair Service 5 years including warranty datasheet of each probe and accessory model for its unique warranty and calibration terms 18 www tektronix com Recommended Probes Tektronix offers over 100 different probes to meet your application needs For a comprehensive listing of available probes please visit www tektronix com probes Probe Description TPP0500 500 MHz 10X TekVPI passive voltage probe with 3 9 pF input capacitance TPP1000 1 GHz 10X TekVPI passive voltage probe with 3 9 pF input capacitance TAP1500 1 5 GHz TekVPI active single ended voltag
3. 39 669k Violations 1 1 Total Tests 1 Failed Tests 1 Elapsed Time 14 145 Total Hits CEEE z B 00GS s l f 2 06 vi 10k points imi aaek Limit Mas Mast i Limit Test Test ak h O Limit Test showing a mask created from a golden waveform and compared against a live signal Results showing statistical information about the test are displayed Snow fests Additionally custom masks can be created and used for characterizing signals Tailor a test to your specific requirements by defining test duration in number of waveforms Or time a violation threshold that must be met before considering a test a failure counting hits along with statistical information and actions upon violations test failure and test complete Whether specifying a mask from a known good signal or from a custom or standard mask conducting pass fail tests in search of waveform anomalies such as glitches has never been easier Video Design and Development Many video engineers have remained loyal to analog oscilloscopes believing the intensity gradations on an analog display are the only way to see certain video waveform details The MSO DPO4000B Series fast waveform capture rate coupled with its intensity graded view of the signal provides the same information rich display as an analog oscilloscope but with much more detail and all the benefits of digital oscilloscopes Standard features such as IRE and mV graticules holdoff by fields video pola
4. direct printing to all PictBridge compatible printers USB 2 0 Device Port LAN Port RJ 45 connector supports 10 100 1000 Mb s XGA Video Port DB 15 female connector connect to show the oscilloscope display on an external monitor or projector Auxiliary Input Front panel BNC connector Input Impedance 1 MQ Maxinput 300 Vams CAT Il with peaks lt 425 V Probe Compensator Front panel pins Output Amplitude 2 5 V Frequency 1 kHz Auxiliary Out Rear panel BNC connector Vour Hi 22 5 V open circuit 21 0 V 50 Q to ground Vour Lo 0 7 V into a load of lt 4 mA 0 25 V 50 Q to ground Output can be configured to provide a pulse out signal when the oscilloscope triggers the internal oscilloscope reference clock out or an event out for limit mask testing Time base system can phase lock to an external 10 MHz reference 10 MHz 1 Rear panel security slot connects to standard Kensington lock External Reference In Kensington Lock LAN eXtensions for Instrumentation LXI Characteristic Description Class LXI Class C Version V1 3 Power Source Characteristic Description Power Source Voltage 100 to 240 V 10 Power Source Frequency 45 to 66 Hz 85 to 264 V 360 to 440 Hz 100 to 132 V Power Consumption 225 W maximum www tektronix com 15 Data Sheet Physical Characteristics Dimensions Height Width Depth Weight Net Shipping Rackmount Configuration Cooling Clearance VESA Mount Environme
5. reduces random noise and increases vertical resolution Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms div Waveform Measurements Measurement Cursors Automatic Measurements Measurement Statistics Reference Levels Gating Waveform Histogram Waveform Histogram Measurements Description Waveform and Screen 29 of which up to four can be displayed on screen at any one time Measurements include Period Frequency Delay Rise Time Fall Time Positive Duty Cycle Negative Duty Cycle Positive Pulse Width Negative Pulse Width Burst Width Phase Positive Overshoot Negative Overshoot Peak to Peak Amplitude High Low Max Min Mean Cycle Mean RMS Cycle RMS Positive Pulse Count Negative Pulse Count Rising Edge Count Falling Edge Count Area and Cycle Area Mean Min Max Standard Deviation User definable reference levels for automatic measurements can be specified in either percent or units Isolate the specific occurrence within an acquisition to take measurements on using either the screen or waveform cursors A waveform histogram provides an array of data values representing the total number of hits inside of a user defined region of the display A waveform histogram is both a visual graph of the hit distribution as well as a numeric array of values that can be measured Sources Channel 1 Channel 2 Channel 3 Channel 4 Ref 1 Ref 2 Ref 3 Ref
6. time stamp information Signal Inputs Any Ch1 Ch4 and any DO D15 on MSO models Recommended Probing 12S LJ RJ TDM Single ended Automotive Serial Triggering and Analysis Module Enables triggering on packet level information on CAN and LIN buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs LIN Any Ch1 Ch4 and any DO D15 on MSO models CAN Any Ch1 Ch4 and any DO D15 on MSO models single ended probing only Recommended Probing LIN Single ended CAN single ended or differential DPO4AUTOMAX Extended Automotive Serial Triggering and Analysis Module Enables triggering on packet level information on CAN LIN and FlexRay buses aswell as analytical tools such as digital views of the signal bus views packet decoding search tools packet decode tables with time stamp information and eye diagram analysis software Signal Inputs LIN Any Ch1 Ch4 and any DO D15 on MSO models CAN Any Ch1 Ch4 and any DO D15 on MSO models single ended probing only FlexRay Any Ch1 Ch4 and any DO D15 on MSO models single ended probing only Recommended Probing LIN Single ended CAN FlexRay Single ended or differential DPO4COMP Computer Serial Triggering and Analysis Module Enables triggering on packet level information on RS 232 422 485 UART buses as well as anal
7. 080p 25 1080p 30 1080p 50 Optional 1080p 60 and custom bi level and tri level sync video standards I2C Optional Trigger on Start Repeated Start Stop Missing ACK Address 7 or 10 bit Data or Address and Data on 12C buses up to 10 Mb s SPI Optional Trigger on SS active MOSI MISO or MOSI and MISO on SPI buses up to 50 Mb s 12 www tektronix com Mixed Signal Oscilloscopes MSO4000B DPO4000B Series Mode Description USB Optional Low speed Trigger on Sync Reset Suspend Resume End of Packet Token Address Packet Data Packet Handshake Packet Special Packet Error Token packet trigger Any token type SOF OUT IN SETUP Address can be specified for Any Token OUT IN and SETUP token types Address can be further specified to trigger on lt lt gt 2 a particular value or inside or outside of a range Frame number can be specified for SOF token using binary hex unsigned decimal and don t care digits Data packet trigger Any data type DATAO DATA Data can be further specified to trigger on lt lt gt 2 a particular data value or inside or outside of a range Handshake packet trigger Any handshake type ACK NAK STALL Special packet trigger Any special type Reserved Error trigger PID Check CRC5 or CRC16 Bit Stuffing Full speed Trigger on Sync Reset Suspend Resume End of Packet Token Address Packet Data Packet Handshake Packet Special Packet Err
8. 4 Math Types Vertical Horizontal Waveform Count Hits in Box Peak Hits Median Max Min Peak to Peak Mean Standard Deviation Sigma 1 Sigma 2 Sigma 3 14 www tektronix com Waveform Math Characteristic Arithmetic Math Functions FFT Advanced Math Description Add subtract multiply and divide waveforms Integrate Differentiate FFT Spectral magnitude FFT Vertical Scale Linear RMS or dBV RMS FFT Window Settings Rectangular Hamming Hanning Blackman Harris Define extensive algebraic expressions including waveforms reference waveforms math functions Perform math on math using complex equations FFT Intg Diff Log Exp Sart Abs Sine Cosine Tangent Rad Deg scalars up to two user adjustable variables and results of parametric measurements Period Freq Delay Rise Fally PosWidth NegWidth BurstWidth Phase PosDutyCycle NegDutyCycle PosOverShoot NegOverShoot PeakPeak Amplitude RMS CycleRMS High Low Max Min Mean CycleMean Area CycleArea and trend plots e g Intg Ch1 Mean Ch1 x1 414xVAR1 Power Measurements Optional Measurement Power Quality Measurements Switching Loss Measurements Harmonics Ripple Measurements Modulation Analysis Safe Operating Area dV dt and dl dt Measurements Description Veams V crest Factors Frequency laws crest Factor True Power Apparent Power Reactive Power Power Factor Phase Angle Power Loss Toan Tor Co
9. GS s Sample Rate on All Channels 20 Megapoint Record Length on All Channels gt 90 000 wim s Maximum Waveform Capture Rate Standard Passive Voltage Probes with Less than 4 pF Capacitive Loading and 500 MHz or 1 GHz Analog Bandwidth Suite of Advanced Triggers Ease of Use Features Wave Inspector Controls provide Easy Navigation and Automated search of Waveform Data 41 Automated Measurements Waveform Histograms and FFT Analysis for Simplified Waveform Analysis TekVPI Probe Interface supports Active Differential and Current Probes for Automatic Scaling and Units 10 4 in 264 mm Bright XGA Color Display Small Footprint and Lightweight Only 5 8 in 147 mm deep and 11 Ib 5 kg Connectivity Two USB 2 0 Host Ports on the Front Panel and Two on the Rear Panel for Quick and Easy Data Storage Printing and Connecting a USB Keyboard USB 2 0 Device Port on Rear Panel for Easy Connection to a PC or Direct Printing to a PictBridge compatible Printer Integrated 10 100 1000BASE T Ethernet Port for Network Connection and Video Out Port to Export the Oscilloscope Display to a Monitor or Projector Optional Serial Triggering and Analysis Automated Serial Triggering Decode and Search Options for 12C SPI USB Ethernet CAN LIN FlexRay RS 232 422 485 UART MIL STD 1553 and I2S LJ RJ TDM Mixed Signal Design and Analysis MSO Series Automated Triggering Decode and Search on Par
10. Mark front panel button to place one or more marks on the waveform Navigating between marks is as simple as pressing the Previous lt and Next buttons on the front panel Search Marks The Search button allows you to automatically search through your long acquisition looking for user defined events All occurrences of the event are highlighted with search marks and are easily navigated to using the front panel Previous lt and Next buttons Search types include edge pulse width glitch timeout runt logic setup and hold rise fall time parallel bus and I2C SPI USB Ethernet CAN LIN FlexRay RS 232 422 485 UART MIL STD 1553 and 2S LJ RJ TDM packet content 2 ee 3 ET ER 5 00GS s in 10k points Digital phosphor technology enables greater than 50 000 wfm s waveform capture rate and real time intensity grading on the MSO DPO4000B Series Digital Phosphor Technology The MSO DPO4000B Series digital phosphor technology provides you with fast insight into the real operation of your device Its fast waveform capture rate greater than 50 000 wim s gives you a high probability of quickly seeing the infrequent problems common in digital systems runt pulses glitches timing issues and more Waveforms are superimposed with one another and waveform points that occur more frequently are intensified This quickly highlights the events that over time occur more often or in the case of infrequent anom
11. RC etc Mixed Signal Oscilloscopes MSO4000B DPO4000B Series M 1 00ms p Vertical iv Zoom Factor 50 X Time Identifier DLC Data Event Table 0103 1122 3344 55 1122 3344 5566 7788 FFFF 0000 EEEE 1111 4269 6C6C AE4F FFF1 0272 DF6B 11 10000001 12345678 1597EEB2 1597EEB2 327DE32 140014 160016 18181818 0 1122 33 1122 3344 55 FIF2 F3F4 FSF6 F7 0000 0000 0000 0000 Remote Frame Remote Frame 4568 6C65 7273 DESS CBFA 5D45 AD8 amp C 757 1A55AA55 1597EEA3 13 1122 3344 1122 3344 5566 C1C2 C3C4 B7B6 B4B4 0 2 3 8 8 4 8 1 3 5 7 8 0 0 6 8 2 4 6 8 Ae 20 05 ee Jee 1M E Event table showing decoded Identifier DLC DATA and CRC N every CAN packet in a long acquisition 500000 Bus Decoding Tired of having to visually inspect the waveform to count clocks determine if each bit is a 1 or a0 combine bits into bytes and determine the hex value Let the oscilloscope do it for you Once you ve set up a bus the MSO DPO4000B Series will decode each packet on the bus and display the value in hex binary decimal USB Ethernet MIL STD 1553 LIN and FlexRay only signed decimal 12S LJU RJ TDM only or ASCII USB Ethernet and RS 232 422 485 UART only in the bus waveform Event Table In addition to seeing decoded packet data on the bus waveform itself you can view captured packets in a tabular view much like you would see in a software listing Packets are time s
12. Test Equipment Solutions Datasheet Test Equipment Solutions Ltd specialise in the second user sale rental and distribution of quality test amp measurement T amp M equipment We stock all major equipment types such as spectrum analyzers signal generators oscilloscopes power meters logic analysers etc from all the major suppliers such as Agilent Tektronix Anritsu and Rohde amp Schwarz We are focused at the professional end of the marketplace primarily working with customers for whom high performance quality and service are key whilst realising the cost savings that second user equipment offers As such we fully test amp refurbish equipment in our in house traceable Lab Items are supplied with manuals accessories and typically a full no quibble 2 year warranty Our staff have extensive backgrounds in T amp M totalling over 150 years of combined experience which enables us to deliver industry leading service and support We endeavour to be customer focused in every way right down to the detail such as offering free delivery on sales covering the cost of warranty returns BOTH ways plus supplying a loan unit if available and supplying a free business tool withevery order As well as the headline benefit of cost saving second user offers shorter lead times higher reliability and multivendor solutions Rental of course is ideal for shorter term needs and offers fast delivery flexibility try before you buy zero capital expendi
13. Trigger on Start Frame Delimiter MAC Addresses MAC Q Tag Control Information MAC Length Type IP Header TCP Header TCP IPv4 MAC Client Data End of Packet Idle FCS CRC Error MAC Addresses Trigger on Source and Destination 48 bit address values MAC Q Tag Control Information Trigger on Q Tag 32 bit value MAC Length Type Trigger on lt lt gt 2 a particular 16 bit value or inside or outside of a range IP Header Trigger on IP Protocol 8 bit value Source Address Destination Address TCP Header Trigger on Source Port Destination Port Sequence Number and Ack Number TCP IPv4 MAC Client Data Trigger on lt lt gt 2 a particular data value or inside or outside of a range Selectable number of bytes to trigger on from 1 16 Byte offset options of Don t Care 0 1499 CAN Optional Trigger on Start of Frame Frame Type data remote error overload Identifier standard or extended Data Identifier and Data End of Frame Missing ACK or Bit Stuffing Error on CAN signals up to 1 Mb s Data can be further specified to trigger on lt lt gt 2 or a specific data value User adjustable sample point is set to 50 by default LIN Optional Trigger on Sync Identifier Data Identifier and Data Wakeup Frame Sleep Frame Errors such as Sync Parity or Checksum Errors up to 100 Kb s by LIN definition 20 Kb s FlexRay Optional Trigger on Start of Frame Type of Frame Normal Payload Null S
14. Trigger out pulse set remote interface SRQ Results Display Test status total waveforms number of violations violation rate total tests failed tests test failure rate elapsed time total hits for each mask segment Software Software Description NI LabVIEW A fully interactive measurement software environment SignalExpress Tektronix optimized for the MSO DPO4000B Series enables Edition you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming Standard MSO DPO4000B Series support for acquiring controlling viewing and exporting your live signal data is permanently available through the software The full version SIGEXPTE adds additional signal processing advanced analysis mixed signal sweeping limit testing and user defined step capabilities and is available for a 30 day trial period standard with each instrument Enables fast and easy communication between a Windows PC and the MSO DPO4000B Series using USB or LAN Transfer and save settings waveforms measurements and screen images Included Word and Excel toolbars automate the transfer of acquisition data and screen images from the oscilloscope into Word and Excel for quick reporting or further analysis Provides a standard instrument programming interface for common applications such as LabVIEW LabWindows CVI Microsoft NET and MATLAB E
15. alies occur less often With the MSO DPO4000B Series you can choose infinite persistence or variable persistence including zero persistence determining how long the previous waveform acquisitions stay on screen This allows you to determine how often an anomaly is occurring Accurate High speed Probing The TPP Series probes included standard with every MSO DPO4000B Series oscilloscope provide up to 1 GHz of analog bandwidth and less than 4 pF of capacitive loading The extremely low capacitive loading minimizes adverse affects on your circuits and is more forgiving of longer ground leads And since the probe bandwidth matches your oscilloscope bandwidth you can see the high frequency components in your signal which is critical for high speed applications The TPP Series passive voltage probes offer all the benefits of general purpose probes like high dynamic range flexible connection options and robust mechanical design while providing the performance of active probes Mixed Signal Design and Analysis MSO Series The MSO4000B Series Mixed Signal Oscilloscopes provide 16 digital channels These channels are tightly integrated into the oscilloscope s user Mixed Signal Oscilloscopes MSO4000B DPO4000B Series 1420MH2_CLOCK nt python on Faia a a da hha aha gaa thas aa a a a 25 STROBE F COUNTS F COUNTS F counta Ey COUNTS BICIE L couNTI fy COUNTO o CLOCK WL Parallel 5 00GS s BI Data 1M p
16. allel Buses Per channel Threshold Settings Multichannel Setup and Hold Triggering MagniVu High speed Acquisition Provides 60 6 ps Fine Timing Resolution on Digital Channels Optional Application Support Power Analysis Limit and Mask Testing HDTV and Custom Video Analysis Feature rich Tools for Debugging Mixed Signal Designs With the MSO DPO4000B Mixed Signal Oscilloscope Series you can analyze up to 20 analog and digital signals with a single instrument to quickly find and diagnose problems in complex designs Bandwidths up to 1 GHz and a minimum of 5X oversampling on all channels ensure you have the performance you need to see fast changing signal details To capture long windows of signal activity while maintaining fine timing resolution the MSO DPO4000B Series offers a deep record length of 20M points standard on all channels With Wave Inspector controls for rapid waveform navigation automated serial and parallel bus analysis limit and mask testing and automated power analysis the MSO DPO4000B Oscilloscope Series from Tektronix provides the feature rich tools you need to simplify and speed debug of your complex design Tektronix Data Sheet SY pase OT ay l 1000 points Discover Fast waveform capture rate over 50 000 wfm s maximizes the probability of capturing elusive glitches and other infrequent events Comprehensive Features Speed Every Stage of Debug The MSO DPO4000B Seri
17. ample Rate MagniVu Maximum Record Length MagniVu Minimum Detectable Pulse Width Typical Channel to Channel Skew Typical Maximum Input Toggle Rate All MSO4000B Models 500 MS s 2 ns resolution 20M points 16 5 GS s 60 6 ps resolution 10k points centered around the trigger 1 ns 200 ps 500 MHz Maximum frequency sine wave that can accurately be reproduced as a logic square wave Requires the use of a short ground extender on each channel This is the maximum frequency at the minimum swing amplitude Higher toggle rates can be achieved with higher amplitudes www tektronix com 11 Data Sheet Trigger System Characteristic Main Trigger Modes Trigger Coupling Trigger Holdoff Range Trigger Sensitivity Characteristic Internal DC Coupled Description Auto Normal and Single DC AC HF reject attenuates gt 50 kHz LF reject attenuates lt 50 kHz noise reject reduces sensitivity 20 ns to 8 s Description Trigger Level Range Characteristic Description 8 divisions from center of screen External 8 V Auxiliary Input Any Channel 1 MQ Path For 1 mV div to 4 98 mV div 0 75 div from DC to All models 50 MHZ increasing to 1 3 div at rated bandwidth 50 Q Path For 25 mV div 0 4 div from DC to 50 MHz MSO DPO04054B increasing to 1 div at rated bandwidth MSO DP04034B 50 Q Path 0 4 div from DC to 50 MHZ increasing to 1 div at MSO DP04104B rated bandwidth External Auxilia
18. e probe TDP1500 1 5 GHz TekVPI differential voltage probe with 25 V differential input voltage TDP1000 1 GHz TekVPI differential voltage probe with 42 V differential input voltage TDP0500 500 MHz TekVPI differential voltage probe with 42 V differential input voltage TCP0150 20 MHz TekVPI 150 Ampere AC DC current probe TCP0030 120 MHz TekVPI 30 Ampere AC DC current probe P5200 1 3 kV 25 MHz high voltage differential probe P5205 3 1 3 kV 100 MHz high voltage differential probe P5210 3 5 6 kV 50 MHZ high voltage differential probe P5100 2 5 KV 100X high voltage passive probe 3 Requires TekVPI to TekProbe BNC adapter TPA BNC Recommended Accessories Accessory Description 077 0512 xx service Manual English only SIGEXPTE NI LabVIEW SignalExpress Tektronix Edition Software Full Version FPGAView xx MSO Support for Altera and Xilinx FPGAs TPA BNC TekVPI to TekProbe BNC Adapter TEK USB 488 GPIB to USB Adapter ACD4000B Soft Transit Case HCTEK54 Hard Transit Case Requires ACD4000B RMD5000 Rackmount Kit TEK DPG Deskew Pulse Generator 067 1686 xx Deskew Fixture Warranty Three year warranty covering all parts and labor excluding probes CE ISO 9001 Product s are manufactured in ISO registered facilities ACORENTED BY THE OUTOA COOR FOR CERTCATION GPIB Product s complies with IEEE Standard 488 1 1987 RS 232 C and with Tektronix IEEE 488 Standard Codes and Formats Mixed Signal Oscilloscopes
19. es offers a robust set of features to speed every stage of debugging your design from quickly discovering an anomaly and capturing it to searching your waveform record for the event and analyzing its characteristics and your device s behavior Discover To debug a design problem first you must know it exists Every design engineer spends time looking for problems in their design a time consuming and frustrating task without the right debug tools The MSO DPO4000B Series offers the industry s most complete visualization of signals providing fast insight into the real operation of your device A fast waveform capture rate greater than 50 000 waveforms per second enables you to see glitches and other infrequent transients within seconds revealing the true nature of device faults A digital phosphor display with intensity grading shows the history of a signal s activity by intensifying areas of the signal that occur more frequently providing a visual display of just how often anomalies occur 2 www tektronix com Trigger On aN LAIM points iiini D15 Do Tx Data J Timing Resolution 40 0ns J a a goons cus p Rs 232 sn I Capture Triggering on a specific transmit data packet going across an RS 232 bus A complete set of triggers including triggers for specific serial packet content ensures you quickly capture your event of interest Capture Discovering a device fault is only the first
20. ge 1 MQ Max Input Voltage 50 Q DC Gain Accuracy Channel to Channel Isolation Offset Range Range 1 MQ 50 Q 1 mV div to 50 mV div 1 V 1 V 50 5 mV div to 0 5 V 0 5 V 99 5 mV div 100 mV div to 500 mV div 10 V 10 V 505 mV div to 995 mV div 5 V 5 4g 1 Vidiv to 5 Vidiv 100 V 5 V 5 05 Vidiv to 10 V div 50 V NA Vertical System Digital Channels All MSO4000B Models 16 Digital D15 DO Thresholds Per channel Thresholds Threshold Selections TTL CMOS ECL PECL User Defined User defined Threshold 40V Range Characteristic Input Channels Maximum Input Voltage 42 Voeax Threshold Accuracy 100 mV 3 of threshold setting Input Dynamic Range 30 Vp p 200 MHz 10 Vp p 2200 MHz Minimum Voltage Swing 400 mV Input Impedance 100 kQ Probe Loading 3 pF Vertical Resolution 1 bit Horizontal System Analog Channels Characteristic DPO4034B DPO4054B DPO4104B MSO04034B MS04054B MSO04104B Maximum Sample 2 5 GS s 2 5 GS s 5 GS s Rate All channels Maximum 20M points Record Length All channels Maximum Duration 8 ms 8 ms 4 ms at Highest Sample Rate All channels Time Base Range Time Base Delay 1 ns to 1 000 s 10 divisions to 5000 s 400 ps to 1 000 s Time Range Channel to Channel Deskew Range Time Base 125 ns 5 ppm over any 21 ms interval Accuracy Horizontal System Digital Channels Characteristic Maximum Sample Rate Main Maximum Record Length Main Maximum S
21. he LAN port The included LXI web interface provides information about the current configuration of your MSO DPO4000B Series oscilloscope including network configuration You can make changes to the network configuration of your MSO DPO4000B Series oscilloscope directly from the web interface through a password protected web page Additionally the popular e Scope remote instrument control is enabled on the MSO DPO4000B Series It continues to offer control of instrument settings saving of screen images and instrument data and saving loading of instrument setups through a standard web browser Characteristics Vertical System Analog Channels Characteristic DPO4034B MSO04034B Input Channels Analog Bandwidth 3 dB 5 mV div 350 MHz 1 Vidiv Mixed Signal Oscilloscopes MSO4000B DPO4000B Series DPO4054B MS04054B 4 500 MHz DPO4104B MSO4104B 1 GHz Calculated Rise Time 5 mV div typical 1 ns Hardware Bandwidth Limits 20 MHz or 250 MHz Input Coupling 700 ps AC DC 350 ps 1 MQ 1 50 Q 1 Input Sensitivity 1 MQ Input Impedance Input Sensitivity 50 Q Vertical Resolution 1 mV div to 10 V div 1 mV div to 1 V div 8 bits 11 bits with Hi Res 300 Vrms CAT II with peaks lt 425 V 5 Vrms with peaks lt 20 V 1 5 derated at 0 10 C above 30 C 2100 1 at lt 100 MHz and 230 1 at gt 100 MHz up to the rated bandwidth for any two channels having equal volts div settings Max Input Volta
22. he cutting edge of technology Please visit www tektronix com Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 28 Oct 2010 3GW 20156 9 Tektronix
23. icate additional information is available by zooming in As shown here Zooming in on the white edge reveals a hidden glitch Prevu 10k points la Timing Resolution 60 6ps uk The MagniVu high resolution record provides 60 6 ps timing resolution enabling you to make critical timing measurements on your digital waveforms GS Wy XN ee The multiple transition detection hardware of the MSO4000B Series will show you a white edge on the display when the system detects multiple transitions White edges indicate that more information is available by zooming in or acquiring at faster sampling rates In most cases zooming in will reveal the pulse that was not viewable with the previous settings If the white edge is still present after zooming in as far as possible this indicates that increasing the sample rate on the next acquisition will reveal higher frequency information than the previous settings could acquire 6 www tektronix com The P6616 MSO probe offers two eight channel pods to simplify connecting to your device The MSO4000B Series simplifies channel setup by allowing you to group digital waveforms and enter waveform labels by using a USB keyboard By simply placing digital waveforms next to each other they form a group Once a group is formed you can position all the channels contained in that group collectively This greatly reduces the normal setup time associated with positioning channels individua
24. ital channels in addition to its analog channels Since the digital channels are fully integrated into the oscilloscope you can trigger across all input channels automatically time correlating all analog digital and serial signals The MagniVu high speed acquisition enables you to acquire fine signal detail up to 60 6 ps resolution around the trigger point for precision measurements MagniVu is essential for making accurate timing measurements for setup and hold clock delay signal skew and glitch characterization arri reana Zoom Factor 100 X i DAON m i Bus Search events found 118 Search 2C decode showing results from a Wave Inspector search for Address value 50 Wave Inspector controls provide unprecedented efficiency in viewing and navigating waveform data Search Finding your event of interest in a long waveform record can be time consuming without the right search tools With today s record lengths pushing beyond a million data points locating your event can mean scrolling through thousands of screens of signal activity The MSO DPO4000B Series offers the industry s most comprehensive search and waveform navigation with its innovative Wave Inspector controls These controls speed panning and Zooming through your record With a unique force feedback system you can move from one end of your record to the other in just seconds User marks allow you to mark any location that you may want to
25. l signal processing advanced analysis sweeping and user defined step capabilities 10 www tektronix com LXI Tektronix MSO4104B MSO4104B 053CXN 134 62 70 174 Windows Internet Explorer 6 E http mso4104b 053exnj gt casa File Edit View Favorites Tools Help We Be GLxr Tektronix ms041048 M5041048 053CXN 134 fh gt Bl ab Pae Gtosk Qi wD Tektronix Fa Tektronix com Products Hf Home Welcome MSO4104B Web Enabled User Network Instrument Information Configuration Instrument Model MS04104B Manufacturer Tektronix SUPPORT Serial Number CQ000016 z i Tektronix Oscilloscope MS04104B t Datasheets Descri ption 053CXN Manuals Firmware Version 0 20055 Driver Download Help Network Information Hostname MS04104B 053CXN local MAC Address 08 00 11 1E 77 FC LXI TCP IP Address 134 62 70 174 Instrument Address String TCPIP 134 62 70 174 INSTR LXI Identification on Instrument OOn Off LXI Information LXI Class c LXI Version 13 Done i CS Local intranet A100 The LXI web interface provides access to network settings enables remote instrument control ands accessible from any standard web browser For simple tasks the included OpenChoice Desktop enables fast and easy communication between the oscilloscope and your PC through USB or LAN for transferring settings waveforms and screen images The MSO DPO4000B Series can also be connected to your network using t
26. les analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information for low speed full speed and high speed USB serial buses Signal Inputs Low speed and Full speed Any Ch1 Ch4 and any DO D15 on MSO models for single ended Any Ch1 Ch4 for differential High speed Any Ch1 Ch4 Recommended Probing Low speed and Full speed Single ended or differential High speed Differential USB high speed supported only on MSO4104B and DPO4104B models Power Analysis Application Module Enables quick and accurate analysis of power quality switching loss harmonics safe operating area SOA modulation ripple and slew rate dl dt dV dt DPO4USB DPO4PWR DPO4LMT Limit and Mask Testing Application Module Enables testing against limit templates generated from golden waveforms and mask testing using custom or standard telecommunications or computer masks DPO4VID HDTV and Custom nonstandard Video Triggering Module www tektronix com 17 Data Sheet Instrument Options Power Plug Options Option Opt AO Opt Opt Opt Opt Opt Opt Opt A1 A2 A3 A5 A6 A10 A11 Opt A99 Language Options 1 Option Opt LO Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 Opt L99 1 Language options include a translated front panel overlay for the selected language s
27. lly MagniVu High speed Acquisition The main digital acquisition mode on the MSO4000B Series will capture up to 20M points at 500 MS s 2 ns resolution In addition to the main record the MSO4000B Series provides an ultra high resolution record called MagniVu which acquires 10 000 points at up to 16 5 GS s 60 6 ps resolution Both main and MagniVu waveforms are acquired on every trigger and can be switched between in the display at any time running or stopped MagniVu provides significantly finer timing resolution than comparable MSOs on the market instilling confidence when making critical timing measurements on digital waveforms P6616 MSO Probe This unique probe design offers two eight channel pods Each channel ends with a probe tip featuring a recessed ground for simplified connection to the device under test The coax on the first channel of each pod is colored blue making it easy to identify The common ground uses an automotive style connector making it easy to create custom grounds for connecting to the device under test When connecting to square pins the P6616 has an adapter that attaches to the probe head extending the probe ground flush with the probe tip so you can attach to a header The P6616 offers outstanding electrical characteristics having only 3 pF of capacitive loading a 100 kQ input resistance and capable of acquiring toggle rates gt 500 MHz and pulses as short as 1 ns in duration _ PreVu _ Trigger O
28. n sync Out HAd 2H 2 01 sync Datal DO 2E 20 20 D3 20 20 20 at 1 00ys F 50GS s PT 1M points iia poine eae ese ae ee D15 Do Token Packet Timing Resolution 2 00ns i Cate ee ss Me ae SSS Bus mee Packet OUT XXh Normal Triggering on a specific OUT Token packet on a USB full speed serial bus The yellow waveform is the D and the blue waveform is the D A bus waveform provides decoded packet content including Start Sync PID Address End Point CRC Data values and Stop Serial Triggering and Analysis Optional On a serial bus a single signal often includes address control data and clock information This can make isolating events of interest difficult The MSO DPO4000B Series offers a robust set of tools for debugging serial buses with automatic trigger decode and search for 12C SPI USB Ethernet CAN LIN FlexRay RS 232 422 485 UART MIL STD 1553 and I2S LJU RJ TDM Serial Triggering Trigger on packet content such as start of packet specific addresses specific data content unique identifiers etc on popular serial interfaces such as 12C SPI USB Ethernet CAN LIN FlexRay RS 232 422 485 UART MIL STD 1553 and 2S LJ RJ TDM Bus Display Provides a higher level combined view of the individual signals clock data chip enable etc that make up your bus making it easy to identify where packets begin and end and identifying subpacket components such as address data identifier C
29. nables control of the MSO DPO4000B Series over a network connection through a standard web browser Simply enter the IP address or network name of the oscilloscope followed by 81 to represent connecting through Port 81 and a web page will be served to the browser Connect to the MSO DPO4000B Series through a standard web browser by simply entering the oscilloscope s IP address or network name in the address bar of the browser The web interface enables viewing of instrument status and configuration and Status and modification of network settings All web interaction conforms to LXI Class C specification OpenChoice Desktop IVI Driver e Scope LXI Class C Web Interface Mixed Signal Oscilloscopes MSO4000B DPO4000B Series Display Characteristics Description 10 4 in 264 mm liquid crystal TFT color display 1 024 horizontal x 768 vertical pixels XGA Vectors Dots Variable Persistence Infinite Characteristic Display Type Display Resolution Waveform Styles Persistence Graticules Full Grid Solid Cross Hair Frame IRE and mV Format YT and simultaneous XY YT Waveform Capture Rate gt 50 000 wim s maximum Input Output Ports Port Description USB 2 0 High speed Host Supports USB mass storage devices printers and Port keyboard Two ports on front and two ports on rear of instrument Rear panel connector allows for communication control of oscilloscope through USBTMC or GPIB with a TEK USB 488 and
30. nduction Total Energy Loss Ton Tor Conduction Total THD F THD R RMS measurements Graphical and table displays of harmonics Test to IEC61000 3 2 Class A and MIL STD 1399 V ripple and lippi Graphical display of Pulse Width Pulse Width Period Frequency Duty Cycle and Duty Cycle modulation types Graphical display and mask testing of switching device safe operating area measurements Cursor measurements of slew rate Limit Mask Testing Optional Characteristic Description Included Standard Masks ITU T ANSI T1 102 USB Test Source Limit Test Any Ch1 Ch4 or any R1 R4 Mask Test Any Ch1 Ch4 Limit test vertical tolerance from 0 to 1 division in 1m division increments Limit test horizontal tolerance from 0 to 500 m division in 1 m division increments Load standard mask from internal memory Load custom mask from text file with up to 8 segments Lock to Source ON mask automatically re scales with source channel settings changes Lock to Source OFF mask does not re scale with source channel settings changes Mask Creation Mask Scaling Test Criteria Run Until Minimum number of waveforms from 1 to 1 000 000 Infinity Minimum elapsed time from 1 second to 48 hours Infinity Violation Threshold From 1 to 1 000 000 Actions on Test Failure Stop acquisition save screen image to file save waveform to file print screen image trigger out pulse set remote interface SRQ Actions on Test Complete
31. ntal Characteristic Temperature Operating Nonoperating Humidity Operating Nonoperating Altitude Operating Nonoperating Regulatory Electromagnetic Compatibility Safety 16 www tektronix com mm in 229 9 0 439 17 3 147 5 8 kg Ib 5 11 10 7 23 6 5U 2 in 51 mm required on left side and rear of instrument Standard MIS D 100 100 mm VESA mounting points on rear of instrument Description 0 C to 50 C 20 C to 60 C High 40 C to 50 C 10 to 60 Relative Humidity Low 0 C to 40 C 10 to 90 Relative Humidity High 40 C to 60 C 5 to 60 Relative Humidity Low 0 C to 40 C 5 to 90 Relative Humidity 9 843 ft 3 000 m 30 000 ft 9 144 m EC Council Directive 2004 108 EC UL61010 1 Second Edition CSA61010 1 Second Edition EN61010 1 2001 IEC 61010 1 2001 Ordering Information MSO DPO4000B Family Model Description DPO4000B Models DPO4034B 350 MHz 2 5 GS s 20M record length 4 channel digital phosphor oscilloscope DPO4054B 500 MHz 2 5 GS s 20M record length 4 channel digital phosphor oscilloscope DPO4104B 1 GHz 5 GS s 20M record length 4 channel digital phosphor oscilloscope MSO4000B Models MS04034B 350 MHz 2 5 GS s 20M record length 4 16 channel mixed signal oscilloscope MS04054B 500 MHz 2 5 GS s 20M record length 4 16 channel mixed signal oscilloscope MS04104B 1 GHz 5 GS s 20M record length 4 16 channel mixed signal oscillosco
32. nus to adjust your zoom view The outer control pans the zoom box across the waveform to quickly get to the portion of waveform you are interested in The outer control also utilizes force feedback to determine how fast to pan on the waveform The farther you turn the outer control the faster the zoom box moves Pan direction is changed by simply turning the control the other way Play Pause A dedicated Play Pause front panel button scrolls the waveform across the display automatically while you look for anomalies or an event of interest Playback speed and direction are controlled using the intuitive pan control Once again turning the control further makes the waveform scroll faster and changing direction is as simple as turning the control the other way 4 www tektronix com Search For e SS Number of Bytes Binary Hex i 0001 0001 11 CED 2 40 Ops 10 0MS s f 3 01 V Bus Search events found 33 1M points Search Search Type Source Bus Search For Identifier Data on Bus BR CAN Id amp Data OXXh 11h Search step 1 You define what you would like to find id 013_ _2 B 11 CE CRC 6IAS_ CED A 2 20 01 10 0MS s f 3 01V Bus Search events found 33 1M points Search step 2 Wave Inspector automatically searches through the record and marks each event with a hollow white triangle You can then use the Previous and Next buttons to jump from one event to the next User Marks Press the Set
33. oints D15 D0 Timing Resolution 2 00ns_ gt 5 00 V 100ns The MSO Series provides 16 integrated digital channels enabling you to view and analyze time correlated analog and digital signals Digital Channel bb Vertical Position 560mdiv eR aa Select 1 600 V 1 400 V i ND 1 400 V Bi Choose Preset 1 600 V oon 1 800 V 2 000 V 2 200 V 2 400 V Various T i a D7 i om 1 00GS s_ 10k points f Timing Resolution D15 D0 Edit MagniVu On Off eee Labels On Off M E Ff 1 44V With the color coded digital waveform display groups are created by simply placing digital channels together on the screen allowing the digital channels to be moved as a group You can set threshold values for each channel enabling support for up to 16 different logic families interface simplifying operation and making it possible to solve mixed signal issues easily Color coded Digital Waveform Display The MSO4000B Series has redefined the way you view digital waveforms One common problem shared by both logic analyzers and mixed signal oscilloscopes is determining if data is a one or a zero when zoomed in far enough that the digital trace stays flat all the way across the display The MSO4000B Series has color coded digital traces displaying ones in green and zeros in blue www tektronix com 5 Data Sheet D15 D0 f Timing Resolution 2 00ns White edges ind
34. or Token packet trigger Any token type SOF OUT IN SETUP Address can be specified for Any Token OUT IN and SETUP token types Address can be further specified to trigger on lt lt gt 2 a particular value or inside or outside of a range Frame number can be specified for SOF token using binary hex unsigned decimal and don t care digits Data packet trigger Any data type DATAO DATA Data can be further specified to trigger on lt lt gt 2 a particular data value or inside or outside of a range Handshake packet trigger Any handshake type ACK NAK STALL Special packet trigger Any special type PRE Reserved Error trigger PID Check CRC5 or CRC16 Bit Stuffing High speed Trigger on Sync Reset Suspend Resume End of Packet Token Address Packet Data Packet Handshake Packet Special Packet Error Token packet trigger Any token type SOF OUT IN SETUP Address can be specified for Any Token OUT IN and SETUP token types Address can be further specified to trigger on lt lt gt 2 a particular value or inside or outside of a range Frame number can be specified for SOF token using binary hex unsigned decimal and don t care digits Data packet trigger Any data type DATAO DATA1 DATA2 DATAM Data can be further specified to trigger on lt lt gt 2 a particular data value or inside or outside of a range Handshake packet trigger Any handshake t
35. ort for controlling the oscilloscope remotely from a PC or for connecting a USB keyboard The USB device port can also be used to print directly to a PictBridge compatible printer An integrated 10 100 1000BASE T Ethernet port enables easy connection to networks and a Video Out port allows the oscilloscope display to be exported to an external monitor or projector The instrument can mount external network drives for easy storage of screen images setup files or data files Setup or data files can then be directly recalled and loaded into the oscilloscope from the network drive location The MSO DPO4000B Series is LXI Class C compliant Compact Form Factor A compact portable form factor allows the MSO DPO4000B Series to be easily moved between labs and with a depth of just 5 8 in 147 mm it saves you valuable space on your test bench Mixed Signal Oscilloscopes MSO4000B DPO4000B Series The MSO DPO4000B Series compact form factor frees up valuable space on your bench or desktop 00 VRMS SAT HAS auxin Al TekVPI probe interface simplifies connecting your probes to the oscilloscope TekVPI Probe Interface The TekVPI probe interface sets the standard for ease of use in probing In addition to the secure reliable connection that the interface provides TekVPI probes feature status indicators and controls as well as a probe menu button right on the compensation box itself This button brings up a probe menu on
36. pe All Models Include One passive voltage probe per analog channel TPP0500 500 MHz 10X 3 9 pF for 500 MHz and 350 MHz models TPP1000 1 GHz 10X 3 9 pF for 1 GHz models Front Cover 200 5130 xx User Manual 071 2810 xx Documentation CD 063 4300 xx OpenChoice Desktop Software NI LabVIEW SignalExpress Tektronix Edition Software Calibration Certificates document measurement traceability to National Metrology Institute s the Quality System this product is manufactured in is 1509001 registered power cord accessory bag 016 2029 xx and a three year warranty Please specify power plug and manual language version when ordering MSO Models also Include One P6616 16 channel logic probe and a logic probe accessory kit 020 2662 xx Application Modules Module DPO4AERO Description Aerospace Serial Triggering and Analysis Module Enables triggering on packet level information on MIL STD 1553 buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs Any Ch1 Ch4 and any DO D15 on MSO models Recommended Probing Single ended Audio Serial Triggering and Analysis Module Enables triggering on packet level information on 12S LJ RJ and TDM audio buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with
37. reference later for further investigation Or automatically search your record for criteria you define Wave Inspector will instantly search your entire record including analog digital and serial bus data Along the way it will automatically mark every occurrence of your defined event so you can quickly move between events Mixed Signal Oscilloscopes MSO4000B DPO4000B Series Value Mean Min Max Se hi 10 0ns 5 00GS S5 f 2 36V l 10k points Analyze Waveform histogram of a falling edge showing the distribution of edge position jitter over time Included are numeric measurements made on the waveform histogram data Acomprehensive set of integrated analysis tools speeds verification of your design s performance Analyze Verifying that your prototype s performance matches simulations and meets the project s design goals requires analyzing its behavior Tasks can range from simple checks of rise times and pulse widths to sophisticated power loss analysis and investigation of noise sources The MSO DPO4000B Series offers a comprehensive set of integrated analysis tools including waveform and screen based cursors 41 automated measurements advanced waveform math including arbitrary equation editing waveform histograms FFT analysis and trend plots for visually determining how a measurement is changing over time Specialized application support for serial bus analysis power supply design limit and ma
38. rity and an Autoset smart enough to detect video signals make the MSO DPO4000B Series the easiest to use oscilloscope on the market for video applications And with up to a 1 GHz bandwidth and four analog inputs the MSO DPO4000B Series provides ample performance for analog and digital video use The MSO DPO4000B Series video functionality is further extended with the optional DPO4VID video application module DPO4VID provides the industry s most complete suite of HDTV and custom nonstandard video triggers _ The MSO DPO4000B Series is designed to make your work easier The large high resolution display shows intricate signal details Dedicated front panel controls simplify operation Two USB host ports on the front panel allow you to easily transfer screenshots instrument settings and waveform data to a USB thumb drive Designed to Make Your Work Easier Large High resolution Display The MSO DPO4000B Series features a 10 4 in 264 mm bright LED backlit XGA color display for seeing intricate signal details Dedicated Front panel Controls Per channel vertical controls provide simple and intuitive operation No longer do you need to share one set of vertical controls across all four channels Connectivity Two USB host ports on the front panel enable easy transfer of screenshots instrument settings and waveform data to a USB thumb drive The rear panel contains two additional USB host ports and a USB device p
39. ry Input 200 mV from DC to 50 MHz increasing to 500 mV at rated bandwidth Trigger Modes Mode Description Edge Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC HF reject LF reject and noise reject Sequence B trigger Trigger Delay by Time 4 ns to 8 s Or Trigger Delay by Events 1 to 4 000 000 events Pulse Width Trigger on width of positive or negative pulses that are gt lt or a specified period of time 4 ns to 8 s Timeout Trigger when no pulse is detected within a specified time 4 ns to 8 s Runt Trigger on a pulse that crosses one threshold but fails to cross a Second threshold before crossing the first again Logic Trigger when any logical pattern of channels goes false or stays true for specified period of time 4 ns to 8 s Any input can be used as a clock to look for the pattern on a clock edge Pattern AND OR NAND NOR specified for all analog and digital input channels defined as High Low or Don t Care Setup and Hold Trigger on violations of both setup time and hold time between clock and data present on any of the input channels Rise Fall Time Trigger on pulse edge rates that are faster orslower than specified Slope may be positive negative or either Video Trigger on all lines odd even or all flelds on NTSC PAL and SECAM video signals Extended Video Trigger on 480p 60 576p 50 720p 30 5720p 50 720p 60 8751 60 1080i 50 1080i 60 1080p 24 1080p 24sF 1
40. sk testing and video design and development is also available For extended analysis National Instrument s LabVIEW SignalExpress Tektronix Edition provides over 200 built in functions including time and frequency domain analysis data logging and customizable reports www tektronix com 3 Data Sheet z Thresholds Trigger Mode Type Source Polarity 2 00 V Wian Normal kun o Positive 1 00 V Runt Occurs amp Holdoff Wave Inspector controls provide unprecedented efficiency in viewing navigating and analyzing waveform data Zip through your 20M point record by turning the outer pan control 1 Get from the beginning to end in seconds See something of interest and want to see more details Just turn the inner zoom control 2 Wave Inspector Navigation and Search A 20M point record length represents thousands of screens of information The MSO DPO4000B Series enables you to find your event in seconds with Wave Inspector the industry s best tool for navigation and search Wave Inspector offers the following innovative controls Zoom Pan A dedicated two tier front panel control provides intuitive contro ofboth zooming and panning The inner control adjusts the zoom factor or zoom scale turning it clockwise activates zoom and goes to progressively higher zoom factors while turning it counterclockwise results injower zoom factors and eventually turning zoom off No longer do you need to navigate through multiple me
41. step Next you must capture the event of interest to identify root cause Accurately capturing any signal of interest begins with proper probing The MSO DPO4000B Series includes four low capacitance probes for accurate signal capture These industry first high impedance passive voltage probes have less than4 pF of capacitive loading to minimize the affect of the probe on your circuit s operation offering the performance of an active probe with the flexibility of a passive probe The MSO DPO4000B Series provides a complete set of triggers including runt timeout logic pulse width glitch setup hold violation serial packet and parallel data to help quickly find your event With up to a 20M point record length you can capture many events of interest even thousands of serial packets in a single acquisition for further analysis while maintaining high resolution to zoom in on fine signal details From triggering on specific packet content to automatic decode in multiple data formats the MSO DPO4000B Series provides integrated support for the industry s broadest range of serial buses 12C SPI USB Ethernet CAN LIN FlexRay RS 232 422 485 UART MIL STD 1553 and I2S LJU RJ TDM The ability to decode up to four serial and or parallel buses simultaneously means you gain insight into system level problems quickly To further help troubleshoot system level interactions in complex embedded systems the MSO4000B Series offers 16 dig
42. tamped and listed consecutively with columns for each component Address Data etc Search Serial triggering is very useful for isolating the event of interest but once you ve captured it and need to analyze the surrounding data what do you do In the past users had to manually scroll through the waveform counting and converting bits and looking for what caused the event With the MSO DPO4000B Series you can have the oscilloscope automatically search through the acquired data for user defined criteria including serial packet content Each occurrence is highlighted by a search mark Rapid navigation between marks is as simple as pressing the Previous lt and Next buttons on the front panel www tektronix com 7 Data Sheet 360ys 800mv ie 110mA xxy 52 5mW 88 3mW SOA Mask Test Passed Waveforms Acquired 889 Failing Samples 0 2 WAT ras 00ms E S5OMS s l Ff 15 0V 100k points Safe operating area measurement Automated power measurements enable quick and accurate analysis of common power parameters Power Analysis Optional Ever increasing consumer demand for longer battery life devices and for green solutions that consume less power require power supply designers to characterize and minimize switching losses to improve efficiency In addition the supply s power levels output purity and harmonic feedback into the power line must be characterized to comply with national and regional power qualit
43. the oscilloscope display with all relevant settings and controls for the probe The TekVPI interface enables direct attachment of current probes without requiring a separate power supply TekVPI probes can be controlled remotely through USB GPIB or LAN enabling more versatile solutions in ATE environments www tektronix com 9 Data Sheet P Screen Waveform Get amp Send 555 34 4 Preferences 427 Capture m Data Capture Settings Select Instrument EE MS04104B Select Channels E Get Data Save As 7 ral Copy to Clipboard pa MS04104B Crosstalk on data lines Modify Note Tektronix OpenChoice Desktop software enables seamless connection between the oscilloscope and your PC Extended Analysis Acquiring data and measurements from the MSO DPO4000B Series is as simple as connecting a USB cable from the oscilloscope to your PC Key software applications NI LabVIEW SignalExpress Tektronix Edition OpenChoice Desktop and Microsoft Excel and Word toolbars are included standard with each oscilloscope to enable fast and easy direct communication with your Windows PC NI LabVIEW SignalExpress Tektronix Edition enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming The optional Professional Version offers over 200 built in functions that provide additiona
44. ture lower risk and off balance sheet accounting Both second user and rental improve the key business measure of Return On Capital Employed We are based near Heathrow Airport in the UK from where we supply test equipment worldwide Our facility incorporates Sales Support Admin Logistics and our own in house Lab All products supplied by Test Equipment Solutions include No quibble parts amp labour warranty we provide transport for UK mainland addresses Free loan equipment during warranty repair if available Full electrical mechanical and safety refurbishment in our in house Lab Certificate of Conformance calibration available on request Manuals and accessories required for normal operation Free insured delivery to your UK mainland address sales Support from our team of seasoned Test amp Measurement engineers ISO9001 quality assurance Test equipment Solutions Ltd Unit 8 Elder Way Waterside Drive Langley Berkshire SL3 6EP T 44 0 1753 596000 F 44 0 1753 596001 Email info TestEquipmentHQ com Web www TestEquipmentHQ com Mixed Signal Oscilloscopes MSO4000B DPO4000B Series Data Sheet g f i s O j A f o gr y i ir 0 paol y COOL D Features amp Benefits Key Performance Specifications 1 GHz 500 MHz 350 MHz Bandwidth Models 4 Analog Channel Models 16 Digital Channels MSO Series Up to 5
45. y standards Historically making these and many other power measurements on an oscilloscope has been a long manual and tedious process The MSO DPO4000B Series optional power analysis tools greatly simplify these tasks enabling quick and accurate analysis of power quality switching loss harmonics safe operating area SOA modulation ripple and slew rate di dt dv dt Completely integrated into the oscilloscope the power analysis tools provide automated repeatable power measurements with a touch of a button no external PC or complex software setup is required Limit Mask Testing Optional A common task during the development process is characterizing the behavior of certain signals in a system One method called limit testing is to compare a tested signal to a known good or golden version of the same signal with user defined vertical and horizontal tolerances Another common method called mask testing is to compare a tested signal to a mask looking for where a signal under test violates the mask The MSO DPO4000B Series offers both limit and mask testing capability useful for long term signal monitoring characterizing signals during design or testing on a production line A robust set of telecommunications and computer standards are provided to test for compliance to a standard 8 www tektronix com Show Results Show Results Limit Mask Test Results Current Totals Test Statu Failed n a Total wavatornic 39 669k
46. ync Startup Identifier Cycle Count Complete Header Field Data Identifier and Data End of Frame or Errors such as Header CRC Trailer CRC Null Frame Sync Frame or Startup Frame Errors up to 100 Mb s RS 232 422 485 UART Trigger on Tx Start Bit Rx Start Bit Tx End of Packet Rx End of Packet Tx Data Rx Data Tx Parity Error and Rx Parity Error up to 10 Mb s Optional MIL STD 1553 Trigger on Sync Word Type Parity Error Data can be further specified to trigger on lt lt gt 2 a specific data value or inside or outside of Optional a range www tektronix com 13 Data Sheet Mode I2S LJ RJ TDM Optional Parallel Available on MSO models only Acquisition Modes Mode Sample Peak Detect Averaging Envelope Hi Res Roll Description Trigger on Word Select Frame Sync or Data Data can be further specified to trigger o a range Maximum data rate for 2S LJ RJ is 12 5 Mb s Maximum data rate for TDM is 25 Mb s ns lt gt 2 a specific data value or inside or outside of Trigger on a parallel bus data value Parallel bus can be from 1 to 20 bits in size Binary and Hex radices are supported Description Acquire sampled values Captures glitches as narrow as 800 ps 1 GHz models or 1 6 ns 500 MHz and 350 MHz models at all sweep speeds From 2 to 512 waveforms included in average Min Max envelope reflecting Peak Detect data over multiple acquisitions Real time boxcar averaging
47. ype ACK NAK STALL NYET Special packet trigger Any special type ERR SPLIT PING Reserved SPLIT packet components that can be specified include Hub Address Start Complete Don t Care Start SSPLIT Complete CSPLIT Port Address Start and End bits Don t Care Control Bulk Interrupt Full speed Device Low speed Device Isochronous Data is Middle Data is End Data is Start Data is All Endpoint Type Don t Care Controlisochronous Bulk Interrupt Error trigger PID Check CRC5 or CRC 16 Any High speed support only available on MSO4104B and DPO4104B models Ethernet Optional 10BASE T Trigger on Start Frame Delimiter MAC Addresses MAC Q Tag Control Information MAC Length Type IP Header TCP Header TCP IPv4 MAC Client Data End of Packet FCS CRC Error MAC Addresses Trigger on Source and Destination 48 bit address values MAC Q Tag Control Information Trigger on Q Tag 32 bit value MAC Length Type Trigger on lt lt gt 2 a particular 16 bit value or inside or outside of a range IP Header Trigger on IP Protocol 8 bit value Source Address Destination Address TCP Header Trigger on Source Port Destination Port Sequence Number and Ack Number TCP IPv4 MAC Client Data Triggerson lt lt gt 2 a particular data value or inside or outside of a range Selectable number of bytes to trigger on from 1 16 Byte offset options of Don t Care 0 1499 100BASE TX
48. ytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs Any Ch1 Ch4 and any DO D15 on MSO models single ended probing only Recommended Probing RS 232 UART Single ended RS 422 485 Differential DPO4AUDIO DPO4AUTO Mixed Signal Oscilloscopes MSO4000B DPO4000B Series Module DPO4EMBD Description Embedded Serial Triggering and Analysis Module Enables triggering on packet level information on 2C and SPI buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs 12C Any Ch1 Ch4 and any DO D15 on MSO models SPI Any Ch1 Ch4 and any DO D15 on MSO models Recommended Probing 12C SPI Single ended DPO4ENET Ethernet Serial Triggering and Analysis Module Enables triggering on packet level information on 10BASE T and 100BASE TX buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs Any Ch1 Ch4 Recommended Probing 10BASE T Single ended or differential 1OOBASE TX Differential USB Serial Triggering and Analysis Module Enables triggering on packet level content for low speed full speed and high speed USB serial buses Also enab
Download Pdf Manuals
Related Search
Related Contents
Power Saver takeMS TMS-CR6411 card reader Metallic Red Accents 4 Slice Toaster 242020 User Manual User Manual V8.3 10171 0611 ›ü™ù.xdw Mr. Coffee 114202 Coffeemaker User Manual Creating a Plastics Injection Molding Machine Control Solution Smeg SC45MNE2 microwave CGS 6.2.6 Release Notes Bassman 100T_091058a.indd Copyright © All rights reserved.
Failed to retrieve file