Home

USER MANUAL KINGKRAFT CHANGING TABLE

image

Contents

1. WEEE Waste Electrical and Electronic Equipment Regulations 2006 The aim of this Directive is to minimise the impact of electrical and electronic equipment on the environment when products become waste All electrical components on this product must be disposed of in accordance to the WEEE 2006 regulations either through reuse recovery recycling or environmentally sound disposal If this Kingkraft product is at the end of its life or electrical parts are replaced during its life cycle by people other than Kingkraft Engineers please contact Kingkraft to discuss arrangements regarding the disposal of any of the electrical equipment Inge B 26D Orgreave Crescent Dore House Industrial Estate Sheffield S13 9NQ tel 0114 269 0697 fax 0114 269 5145 e mail info kingkraft co uk url www kingkraft co uk Page 12 of 12
2. of 12 Care of the unit The system must not be overloaded It is designed to operate with only one person at a time Should overload occur a cut out may operate and the unit will not operate until the overload has been removed and the system has automatically reset itself normally within a few seconds Should gross overload occur physical damage to the actuator or the trolley may occur and the unit may descend to its lowest point The unit should not be used if cabling or other components appear damaged The system is designed to operate in a bathing showering area but the components should not be submerged in water or subjected to pressure washing Kingkraft recommend Trigene for disinfection of the surfaces The components should be dry before reusing Fault finding If the system doesn t operate please check as follows Is the battery charged Are all leads and connections fully engaged sthe battery securely clamped in place Has the emergency stop button been activated if fitted Should the above fail to correct the problem please contact Kingkraft Page 8 of 12 Below are diagrams representing all possible basic electrical circuits incorporated into the Changing Table Do not attempt to open the electrical boxes Do not immerse the power cord in water or run over it trap it with mobile devices Mobile Battery Lifting Frame Pendant L Power Control Box N Charger Battery 24 V DC So
3. USER MANUAL KINGKRAFT CHANGING TABLE IMPORTANT SAFETY INSTRUCTONS Please read these instructions carefully before first using your Kingkraft product and then keep them safely for future reference Please also make sure that each person and any carer who uses the bath is also aware of their contents and follows the instructions each time they use the unit Kinokraft INOFL 26D Orgreave Crescent Dore House Industrial Estate Sheffield S13 9NQ tel 0114 269 0697 fax 0114 269 5145 e mail info kingkraft co uk url www kingkraft co uk CTMH ISSUE 1 08 2010 CONTENTS KINGKRAFT CHANGING TABLE IMPORTANT SAFETY INSTRUCTIONS OPERATING INSTRUCTIONS LIFTING FRAME OPERATIONS BASIC ELECTRICAL CIRCUITS ON UNIT CHANGING TABLE MARKINGS MAINTENANCE RECORD OF UNIT MAINTENANCE GUARANTEE DETAILS Page 2 of 12 THE KINGKRAFT CHANGING TABLE Mobile Variable Height Version Shown Page 3 of 12 IMPORTANT SAFETY INSTRUCTIONS WARNING Any person who is incapable of fully helping themselves must NEVER be left alone on the table even for the shortest of periods This manual contains information for all standard versions of the Kingkraft Changing Table Special design versions manufactured by Kingkraft may differ to those described herein Separate instructions for these models may be required Please consult Kingkraft Ltd These instructions also cover the range of different fixed height and manual and powered raise lower fram
4. ars Battery Actuator Page 9 of 12 SAMPLE CHANGING TABLE MARKINGS The following are examples of markings found on the Changing Table Changing Table identity label Kingkraft Changing Table Read instructions before use Regular inspection service recommended Do not clean with bleach based products Supply rating N A Maximum load 130kg 21 St Serial No 000001 e 4 Meverill Road Tideswell Buxton Kinokraft Derbyshire England SK17 8PY Ter Tel 01298 872309 Fax 01298 872609 Power Actuator Label LAK2J 11 H0 01 24 GE 24 V lin 9 ea CurrentLimit Max 9 A Vout DC 24 E Output Power 216 E Internal Power DC 24 V Battery 4 5 Mto Date 2009 07 29 A Weight 5 04 Kg LP 65 b Duty Cycle Max 10 amp Max 2 Min On lt Note T091015 02 3 SIN TIRE M i 510A090700480010 FA02C0900 HIWIN MIKROSYSTEM CORP Cc is si b www hiwinmikro com tw eee Open lock handle direction Page 10 of 12 MAINTENANCE Most important for the Changing Table is simply a visual inspection to check that the unit is in safe working order If you find any faults with the unit ensure they are rectified immediately and in any event before the table is next used If in doubt about any repair procedure please contact Kingkraft for advice or to arrange a service visit Record of unit maintenance Table No Op
5. de down To lift the side Push or pull the side up Turn handle to locked position Table mattress To secure mattress a Ensure that the table bottom and mattress is clean b Place mattress on bottom of table C Press the mattress firmly on to the bottom of the trolley and secure on velcro fixings When removing the mattress for cleaning take care that the velcro is secured carefully from the table to avoid a tearing action Cleaning your Changing Table The Changing Table is made from Polypropylene plastic and requires only a very mild non abrasive cleaning agent to keep it clean Backrests can be removed for cleaning by simply being lifted clear Under no circumstances must acid or bleach based cleaners be used to clean this product To do so invalidates the guarantee Kingkraft recommend that your Kingkraft Changing Table should be cleaned with TRIGENES which is available from Kingkraft in ready to use 500ml trigger sprays or concentrated in 1Itr and 5ltr sizes Always follow the instructions of the Trigene containers A sample TR101 trigger spray may be included with a new table General cleaning disinfection Use Trigene trigger spray TR101 pre diluted to 1 10 As Trigene is considered safe and non corrosive it can be used on every area of the Trolley and accessories Trigene presents no hazard to the user in normal use Leave for five minutes before rinsing off Page 6 of 12 Lifting frame for raising and
6. e raise lower function Firstly check that the proposed operation will not cause damage to nearby equipment or injury to personnel Press the buttons on the hand set to raise or lower the unit as required Releasing the button will stop the operation If the unit is fitted with the additional feature of a red emergency stop button this may also be activated to cause an immediate stop The unit will not operate until the emergency stop button has been reset this is done by twisting it until it clicks out To remove and recharge the battery The battery clips on and off the mounting bracket on the frame by means of a release lever at the end of the battery When the battery charge level falls to approximately 50 the charge level indicator light will also show this a warning buzzer may sound each time the unit is operated At this stage the battery must be removed and recharged This will ensure maximum battery life To recharge the battery simply unclip it and attach it to the wall mounted battery charger well away from the wet area and free from interference A light will illuminate when the battery is charging and also indicate when charging is complete A further light on the charger indicates that it is connected to the mains An example of a control box and battery installed on a Changing Table lifting frame Note Please check the emergency stop button is not engaged if the actuator does not operate when the handset is pressed Page 7
7. eration Tick Comments OK 1 Check water path s clean NA 2 Let water flow into trolley and check for NA adequate operation of drain 3 Check presence legibility of warning notices 4 Check all labels on bath intact and legible 5 Check frame for excess corrosion 6 Check operation of TMV S NA T N A 8 N A 9 Check charger unit is operating correctly and is safe to use 10 Check all other wires and electrical enclosures for damage 11 Check pipes etc for leaks NA 12 Check all knobs and handles securely attached 13 Check all controls easily operated i e not too stiff 14 Check operation of lifting mechanism 15 Check for unusual noises or vibration when raising lowering table 16 With table empty and at top of travel rock unit from side to side gently to check for loose fittings and instability 17 Record date maintenance carried out Page 11 of 12 18 Record name of person carrying out inspection GUARANTEE DETAILS The Kingkraft Changing Table and its accessories are guaranteed in the U K for a period of twelve months from the date of delivery against defects arising from faulty material inferior workmanship or construction The result of incorrect handling of the Changing Table shall not be covered by the guarantee In line with the company s policy of continual product improvement we reserve the right to carry out improvements to the specification without notice
8. es which may used with the Table Please make sure you read all the sections relevant to your particular model of bath If you have any doubt about the safe operation of the Changing Table please contact Kingkraft immediately for advice Do not stand in the Table when it is in the raised position or at any other time Kingkraft products are intended for domestic and commercial use only Kingkraft Changing Tables are intended only for lifting and use when dressing undressing people Do not exceed the maximum loading marked on the unit chassis Only one person should be in the unit at any one time If fitted the raise lower control handset is waterproof but should not be put into the water However if it is accidentally dropped remove it immediately and wipe dry Do not leave the handset underwater Note that UK regulations require that in general no person should lift a mass of greater than 25kg unaided Use appropriate lifting equipment if this is required to help disabled people to get in and out of the unit The Table must be installed by competent installers Your Kingkraft Changing Table itself should be serviced at least once per year by a competent individual The Table must be cleaned and disinfected regularly according to the instructions given herein Ensure that the safety notices which accompany your Table are properly displayed at all times Make sure they are replaced if they become damaged or defaced Co
9. lowering the Changing Table Kingkraft manufacture different models of lifting frame for the Changing Table in manual amp battery versions In addition a special frame can be specified which requires only minimum clearance at each end during the lifting process This version is designated a vertical rise frame and is typically used when there is limited space available eg in an alcove position Please carefully read the instructions which apply to your model Fixed height frames are also manufactured When the lifting frame is moving the maximum load noise 1 metre away does not exceed 65 dBA Please carefully read the instructions which apply to your model Maximum working load is 130Kg including user mattress and other accessories Manual foot pedal operated models To raise the table Pump the raise pedal fully up and down to desired height first taking care that the raising operation will not trap anybody or damage adjacent equipment To lower the table Press lower pedal down until desired height is reached similarly first checking that the lowering operation will not cause damage to individuals or adjacent equipment Battery Powered Frame models General The battery powered system uses a 24 Volt rechargeable battery which drives a linear actuator A removable battery is supplied with the system together with a wall mounted charger which is to be installed by a competent person in a safe dry area To operate th
10. ntact Kingkraft if you need further supplies of laminated notices Certain bath additives may damage the plastic if they contain bleach or other corrosives from which your product is made Use only water normal soaps and approved cleaning agents If in doubt please contact Kingkraft for advice about the suitability of the additives you wish to use Under no circumstances must acid or bleach based cleaners be used To do so invalidates your guarantee We recommend that your Kingkraft Changing Table should be cleaned with Trigene amp which is available from us See the section on cleaning below for instructions on how to safely and completely clean your unit The charger unit for charging the battery system for raising and lowering the frame if fitted should be installed by a competent individual in a clean dry room away from interference The unit should be disconnected from the mains prior to cleaning which should be confined to wiping with a dry cloth Page 4 of 12 Do not use pressurised water jets to clean the Table chassis and keep water jets away from the controls when cleaning around the Table Do not steam clean Do not attempt maintenance unless the Table is empty Check the Table frequently for damage If you find signs of damage do not use it and contact Kingkraft as soon as possible to arrange for service and repair Page 5 of 12 Operating instructions Changing Table To lower the side Turn handle Push the si

Download Pdf Manuals

image

Related Search

Related Contents

Pdf - 2,05 mb    User Guide - Charles Sturt University  DEPRO AGROFER 14  SOLEX FAIT TOURNER NOS VIES DEPUIS 1946  Preisliste - Duscholux  manual de usuario inspector _2  StorageTek SL8500 User Guide  While in the SETUP menu normally the setup is for viewing only. To  Samsung PG811 Instrukcja obsługi  