1.            USER MANUAL                 605 and COMBO655       COMBO605    UNI RAM CORPORATION   ONTARIO    CANADA    Revision 2009 01    MANUAL   COMBO605        COMBO655 Revision 2009 01    CONTENTS  INTRODUC TION                                           m 3  CGCAUTIONSAND WARNINGS                                                       3  FEATURES AND SPECIFICATIONS                                4  SAFETYEEATURES uuu  u       ee ee ee          4  PREPARATION AND SE                                                               4  SOLVENT REQUIREMENTS                              nter amt notament 4  PAIL SETUP AND CONNECTIONS           arent Racal                 dette          5  OPERATION   SPRAY GUN CLEANING                                              6 7  OPERATION   SOLVENT RECYCLER                                               7 10  THEORY OF OPERATION ec                                        RE 11  FLOW DIAGRAM                          12  TROUBLESHOOTING CU   S Serene eee                    13 14  ERROR CODES  T                                                            15 16  SERVICE PROCEDURES  u uu          ee ee ee ee ee ee ees 17 18  REPLACEMENT PARIS aquya tes cena                                     19  WARRANTY et EE 20    MANUAL   COMBO605 and COMBO655 Revision 2009 01    INTRODUCTION    Uni ram holds many patents on designs used in its innovative products  Every machine is tested for com   pliance with Quality Assurance standards  Follow the instructions 
2.     0 BRUSH                   JET    TAPER NOZZLE DELIVERY TUBE    BOTTOM  CONNECTOR    TRANSFER VALVE    DIAPHRAGM PUMP    MANUAL WASH    DIAP  PUMP  AUTO WASH       FLOW CONTROL    FLOW CONTROL  BALL VALVE    BALL VALVE          SOLVENT FLOW  AIR FLOW    TRANSFER SOLVENT       COMBINATION  OUTLET MBINATI  BOILING TANK LOW LEVEL    RECYCLER GAUGE E  CONDENSER    wig ONL                                           TRANSFER  PUMP    RECYCLED  SOLVENT PAIL    TRANSFER  PUMP                SUCTION             WASH SOLVENT  PAIL       RINSE PUMP    MANUAL WASH    SUCTION PIPE    RINSE SOLVENT PAIL       TRANSFER PUMP  WASH SUL  TO BOILER  S MIN  TIMER   SET 2 MIN        DIAPHRAGM PUMP  MANUAL RINSE       FUME EXTRACTOR       VENTURI SWITCH    VENT CONTROL    AIR REGULATOR          BALL VALVE     AIR INLET        LLL  AUTO WASH H LID SWITCH  TIMER ASSY   60SEC   J              L     MANUAL RINSE  FOOT PEDAL                   AIR VALVE     lt  MANUAL WASH  N FOOT PEDAL      AUTO RINSE  PUSH BUTTON  AIR VALVE  MANUAL RINSE  SUCTION TUBE   ANTE ON             FD COMBO605  MANUAL    TRANSFER PUMP  RECYCLED SDL   5 MIN  TIMER  SET 5 MIN           12    Revision 2009 01    MANUAL   COMBO605        COMBO655    FLOW DIAGRAM   COMBO655       TRANSFER VALVE    FLOW CONTROL  BALL VALVE       DELIVERY TUBE     BOTTOM CONNECTOR              BRUSH    5 SPARY           TAPER NDZZLE          TRANSFER SDLVENT  OUTLET    BOILING TANK  RECYCLER    CONDENSER    RECYCLED  SOLVENT PAIL    SOLVENT FLOW  A
3.   Uni ram makes no warranty or claim  either expressed or  implied with respect to this product s fitness for any purpose or the result to be obtained from its use  This  condition applies to the sale of all products and no representative or distributor of Uni ram Corporation  has the authority to waive or change these conditions     This warranty applies only to the original purchaser and does not apply if the unit has been misused   overloaded  neglected  altered or used for any purpose other than those specified in the operating and  installation instructions  Deterioration due to normal wear is not covered by this warranty  Damage due to  accident  transportation  fire  floods or acts of God is also not covered  Units whose serial numbers have  been altered or removed are not covered  The warranty is invalid if unauthorized abrasives are used in  this unit  Unauthorized attempts at self repair or alterations by the owner also invalidate this warranty   Interior or exterior finishes are not covered by this warranty    Consumable Items are not covered by this warranty    This warranty replaces all other warranties expressed or implied by statute or otherwise     To make a claim  call Uni ram Service at 1 800 417 9133 and quote the serial number of the unit     USE ONLY GENUINE UNI RAM LINER BAGS WHICH ARE 2 MIL THICK  LIGHT BLUE IN COLOUR  WITH A SAWTOOTH EDGE AND A 3 16  WELD     THEY ARE SPECIALLY MANUFACTURED TO BE STRONG  HEAT RESISTANT AND CHEMICAL  RESISTANT     USE O
4.  FLOW PATH   LOOSE HINGE OR CROSS BAR BOLTS ORA SET POINT THAT  IS TOO HIGH FOR THE SOLVENT BEING RECYCLED     This procedure tightens the Lid by increasing  the tension on the spring attached to the Lid  Bar Spring Bolt Assembly  The Lid and Bolt  Assembly is carefully designed as a Safety  Pressure Relief system to prevent a danger   ous build up of pressure inside the closed  tank  Do not adjust the Spring Holding Nut  by more than 2 full turns maximum  If 2  full turns do not solve the problem  call for  service       While holding the top nut with a wrench   turn the nut below the spring no more than  a 1 2 turn at a time  Turn in a counter   clockwise direction  as you look down on  it       After each 1 2 turn  operate the unit nor   mally and check for leaks        5  REPOSITION LID and TIGHTEN HINGE AND CROSS BAR BOLTS    The Hinge bolts can loosen over time  causing the lid to shift off center  This can lead to an inadequate  seal and leaking around the Gasket  Loosen the bolts  reposition the lid and re tighten the bolts     Hinge    Spring Bolt Assembly    Cross Bar       6  RECOMMENDED 6 MONTH MAINTENANCE      Vacuum the condenser  see Service Procedure 1        Clean the solvent flow path by recycling 3 Gal of clean solvent       Inspect Distillation Tank for debris  pitting and or other damage       Inspect Lid Gasket for wear or damage  see Operating Procedure 11      19    MANUAL   COMBO605        COMBO655    DESCRIPTION   Lid Gasket  Standard  Liner Bag  Pkg
5.  at about 30 PSI  2  kg cm2  into the Vapour Outlet  If the air comes out of the Solvent Outlet Tube  the blockage has been  cleared  If not  call for service     3  REPLACE FUSES    Fuses are located on the Power Control Board inside the Motor Housing     Disconnect power supply     Remove the Guard Screen by unscrewing two metal screws to get access to the Motor Housing      Motor Housing    Power Control Board        Front Cover      Unscrew the 6 screws from the Front Cover and pull it gently from the motor housing to expose the  fuses  Note  Care should be taken not to pull the Front Cover too far as some wires may discon   nect      There are two fuses for URS500 series and four fuses for URS600 series     URS500 series  URS600 Series   Fuses F1  250 V 20 0 A 314  Fast type  for Heater There are two each of F1 and F2 fuses   Fuses F2  250 V 2 0 A 312  Slow type  for Fan Motor      Remove the fuses from the board and  using a meter  test each one and replace as needed     Carefully push the Power Control Board back into the Motor Housing      Ensure that the wire to the computer board is secure      Rerinstall the Front Cover using all 6 screws       Install the Guard Screen using two metal screws      Close the Door and re connect the power supply     18    MANUAL   COMBO605 and COMBO655 Revision 2009 01    4  INCREASE LID TENSION  BY ADJUSTING SPRING BOLT   CAUTION     SHOULD BE DONE ONLY AS ALAST RESORT   FIRST CHECK FOR A WORN LID GASKET  A BLOCK   AGE IN THE SOLVENT
6.  flash point below 38 7  C   100  F   These solvents are commonly used in the industry as cleaning solvents or paint diluents     Dirty solvent to be distilled must meet each requirement described below  The Material Safety Data  Sheet  MSDS  provides data on the properties of the virgin solvent     1  The BP  Boiling Point  of the dirty solvent must be less than 200  C  392  F   BP increases with greater  contamination     2  The auto ignition temperature of the solvent to be distilled must be higher than 250  C  482  F  for safe  operation  Do not recycle Nitrocellulose  The auto ignition temperature is 135  C  275  F     Notes       Recycle recently contaminated solvent only  Standing solvent can become acidic over time       To avoid    FISH EYE    problems  do not recycle both paint dilutents and parts washer solvent in the  same unit     DEFINITIONS  Flash Point  The lowest temperature at which the vapor of a solvent can be made to ignite momentarily in air   Auto ignition temperature  often referred to as    ignition temperature    or    ignition point      the temperature at which  solvent ignites by itself     PAIL SETUP AND CONNECTIONS       The unit comes with the pails installed and connected  If the pails need to be reconnected   use this picture as a guide  For safety  make sure the ground wires are connected     MANUAL   COMBO605        COMBO655 Revision 2009 01    OPERATION  SPRAY GUN CLEANING  PRE   CLEAN      Disconnect the spray gun from the air hose  Pour 
7.  of 10  Solvent Outlet Tube    Trigger Clamp and Plug Kit  Pkg of 2    Nozzle Adaptor  Nozzle Adaptor  Sata  Retainer Ring    20    REPLACEMENT PARTS         Neoprene            Revision 2009 01    PART NO   770 2150N  LB900C 10   770 8131   140 2340   110 430  110 430SA   770 9110    MANUAL   COMBO605 and COMBO655 Revision 2009 01    Full Product Warranty    These Uni ram products have been engineered and manufactured to high performance standards  Each  unit has been subjected to detailed factory testing before shipment     This product comes with a one year full warranty from the date of purchase  Uni ram Corporation re   serves the right to repair or replace the unit  free of charge  to the original purchaser if a part is found to  be defective in material or workmanship as determined by factory service personnel  The items listed  below under    Conditions of Warranty    as consumables are not covered     Uni ram reserves the right to direct the customer to ship the unit collect to the Uni ram factory or to an ap   proved Service Center for repair using the Uni ram Return Goods Procedure or to repair the unit on site   To prevent damage in transport  the purchaser must ship the unit in the original packaging or use alter   nate adequate packaging  All units must be shipped clean and free of solvent     Conditions of Warranty    As Uni ram Corporation has no control over the working conditions or circumstances under which the  purchaser stores  handles or uses the product
8.  the Fume Vent to be turned OFF or ON        SOLVENT RECYCLNG    Wear protective clothing in accordance with local safety and environmental regulations  Use face goggles  and gloves as a minimum  Use an apron and respirator if required     The unit is a self contained gun cleaning   solvent recycling system designed to recycle the solvent used  for cleaning guns  The unit can be used at any time to recycle used solvent either on an ongoing basis  for separate storage or to replace the clean solvent used up during gun cleaning  The gun cleaner can be  used while the recycler is in operation     Recycling becomes necessary when the WASH PAIL  middle  becomes full or when the LOW LEVEL  INDICATOR gauge indicates that the solvent level in the CLEAN SOLVENT PAIL is too low  At that point   the guns will no longer be cleaned properly  The level of solvent in the WASH PAIL should be checked  regularly  especially during heavy use as this pail may fill up before the level in the CLEAN RINSE pail  drops to the point where the LOW LEVEL INDICATOR gauge indicates that the level is too low  NOTE   the gauge only indicates the level correctly when the RINSE CYCLE CONTROL button is pushed     1  Open the Tank Lid and Safety Cover       Open the safety cover      Open the inner lid by releasing the Lid Clamp     Make sure that Tank is empty and that a Liner Bag is properly installed in the Tank     PULL UP TO OPEN  PUSH DOWN TO LOCK    LID CLAMP    TANK LID       MANUAL   COMBO605        CO
9. F A NON UNI RAM LINER BAG MAY VOID THE WARRANTY     21    
10. IR FLOW       2    VALVE    SPIGUT    DIAPHRAGM PUMP  MANUAL WASH          FLOW CONTROL  BALL VALVE  FUME EXTRACTOR       VENTURI SWITCH    DIAPHRAGM PUMP  MANUAL RINSE          AIR REGULATOR  AIR INLET                COMBINATION  VALVE  HOSE LOW LEVEL  ICLEANING GAUGE                AUTO WASH  TIMER   55                                     TRANSFER  PUMP          TRANSFER  PUMP        PAIL          MANUAL WASH    SUCTION PIPE  SUCTION TUBE    WASH SOLVENT          MANUAL RINSE  FOOT PEDAL                AIR VALVE       MANUAL WASH  FOOT PEDAL             AUTO RINSE  PUSH BUTTON             RINSE PUMP AIR VALVE    MANUAL RINSE  SUCTION TUBE    AIR RINSE    RINSE SOLVENT PAIL PUSH BUTTON             TRANSFER PUMP  WASH SOL  TO BOILER  5 MIN  TIMER   SET 2 MIN        TRANSFER PUMP       RECYCLED SOL   5 MIN  TIMER  SET 5 MIN     FD COMBO655  REV   C           13    MANUAL   COMBO605        COMBO655    Revision 2009 01    TROUBLESHOOTING GUIDE    Carry out each action step until a solution is found  If the recommended actions do not solve the problem  call Uni ram Service in North America or contact a qualified Service Technician     Caution  Disconnect the power supply before conducting maintenance or service     PROBLEM CAUSE ACTION STEPS    Unit is plugged in  all the lights    on the Panel are Off  the unit     Power board or fuse  not functioning     Unit is plugged in     READY L         READY H   lights are On  Heat  light fails to come on when             button is press
11. MBO655 Revision 2009 01    2  Transfer Solvent TO the Recycler Tank    Verify that the solvent to be recycled complies with the requirements described in the section  Solvent  Requirements       Open the Transfer Valve by TER  turning the handle counter  Recycler   clockwise 90         Turn the Transfer Timer knob  clockwise fully  Dirty solvent will  flow from the Transfer Port into  the Liner Bag and stop when  the timer runs out    e Close the Transfer Valve by  turning the handle clockwise  90        Close the tank Lid  lock down  the Lid Clamp and close the  Safety Cover     Lid Gasket    Transfer Valve    Transfer Port       3  Change temperature set point  as required  If the Temperature Set  Point is satisfactory  skip this section     Conditions to consider before starting Setup     Minimize Temperature Set Point   After recycling there will be a small amount of solvent  about 1 8 US gal  500 ml   remaining in the distil   lation tank due to condensation  Select the lowest Temperature Set Point that recycles the solvent to this  level     Estimate Boiling Point  Add 45  C  81  F  to the boiling point of the pure solvent as shown on the MSDS  Material Safety Data  Sheet  or another reliable source     Recycle more often  The boiling point of the waste solvent mixture increases as it gets dirtier  To reduce the boiling point   recycle more often     The display for the Control Panel is located at the top right corner of the base cabinet   The LEDs for READY L  and READ
12. MP  METERING            oc          PREPARATION AND SETUP      Carefully inspect the shipping carton for any sign of transport damage      Carefully remove the unit from the shipping carton    e Check the unit for damage  Report any transport damage immediately to the carrier and your  vendor  Initiate a freight claim with the carrier  The manufacturer is not responsible for freight dam   age      ALiner Bag and Retainer Ring are already installed inside the distillation tank    e Check the list of included parts  If any parts are missing  contact your supplier      Level the unit using the adjustable feet and install the two handles onto the front panel      Connect the ground wire at the back of the cabinet to an external grounded object        CAUTION  USE ONLY GENUINE UNI RAM LINER BAGS WHICH ARE 2 MIL THICK  LIGHT BLUE  IN COLOUR WITH A SAWTOOTH EDGE AND A 3 16  WELD  THEY ARE SPECIALLY MANUFAC     TURED TO BE STRONG  HEAT RESISTANT AND CHEMICAL RESISTANT  USE OF A NON UNI   RAM LINER BAG MAY VOID THE WARRANTY        MANUAL   COMBO605 and COMBO655 Revision 2009 01    INCLUDED PARTS    MANUAL  LID GASKET RECYCLER  LINER BAG  2 SPARES RECYCLER    SOLVENT OUTLET TUBE RECYCLER  TRIGGER CLAMP AND PLUG KIT  2  GUN CLEANER  NOZZLE ADAPTORS  2  GUN CLEANER       SOLVENT REQUIREMENTS  RECYCLER     This unit recycles flammable solvents and combustible solvents  Flammable solvents include lacquer thin   ner  paint thinner  acetone and other paint diluents  Flammable Solvents have a
13. Y H  on the control panel indicate the Temperature Set Point     To Change the Temperature Set Point    Make sure the    HEAT    and  FAN  lights are off  Press and hold the    OFF    button while pressing the    ON     button repeatedly to cycle through the 6 possible Set Points  If you go past the desired Set Point  continue  to press the    ON    button until you cycle back to the missed Set Point                 UN   TEMPERATURE SET READY LIGHTS   Solvent Recycler  POINTS L M H  90  C  194  F     115      239          TEMPERATURE   L M H HEAT FAN  140  C  284  F                  165      329           200      392             The Temperature Set Point is pre set at the      E  factory to 200  C  392  F    all 3 lights are on  KEYPAD  CONTROL PANEL     MANUAL   COMBO605 and COMBO655 Revision 2009 01    4  Start Recycling    Press    ON    button  Distillation starts     HEAT    and    FAN    lights come on  If you want to stop recycling  press    OFF        5  Finish Recycling     CAUTION  DO NOT OPEN LID UNTIL COOLING IS COMPLETE    The clean recycled solvent is available for use when the heat lamp goes off  Recycling is complete and  the the unit is ready for the next operation when    HEAT    and    FAN    lights are off     6  Transfer Clean Solvent  a  For models without the Solvent Transfer System  remove the pail and replace with an empty one     b  For models with the Solvent Transfer System  turn the Transfer Timer knob clockwise fully  The clean  solvent will flo
14. ed     Recycled solvent is not clear  ing chemically   2  The solvent flow  path is dirty  One    cause is overfilling the    distillation tank     3  Orange colour due  to rust in receiving  pail    4  Milky colour due to  presence of water     1  Poor heat transfer  due to dirt and debris  left in the tank     Dirty solvent remains in Dis   tillation Tank after recycling    Note  1 8 Gal  500 ml  of re   cycled solvent is expected due to  condensation     2  Boiling point of  solvent is above Tem   perature Set Point     1  The solvent is react     Power is not getting to   Reset breaker or replace fuse  If power is    still not getting to the unit  call a Qualified  Service Technician  Ensure that the unit is  the only device on a circuit with sufficient  capacity    Call Uni ram Service    1  Lower Termperature Set Point following  Operating Procedure 4     2  To clean the path  follow Service Pro   cedure 2 and then recycle 3 gal of clean  solvent     3  Place a jar under outlet tube and capture  some solvent  If the solvent is clear  replace  the pail with a non corrosive one     4  Eliminate source of water in solvent     1  Clean the tank  replace the Liner Bag   recycle with pure solvent to test  If suc   cessfull  the problem is due to a dirty tank   debris left in the tank or the solvent is too  contaminated  Adjust accordingly  Follow  Operating Procedures closely  If the level  of contamination is too high  recycle more  often     2  Raise the Temperature Set Poi
15. ere is excessive pitting  call a Service  Technician and replace the tank with a corrosive resistant  stainless steel one     Lid Surface     Use    cloth  Dry and clean the lid and the top of tank where the the Lid Gasket sits to extend the life of the  Lid Gasket and prevent leakage  Avoid rotating the lid during cleaning  The lid gasket is a wear item     MANUAL   COMBO605        COMBO655 Revision 2009 01    9  Install new Liner Bag  Lift Recycler Safety Cover and Tank Lid fully  lids will stay in the open position     a  Install the Liner Bag so that the bottom of the Bag sits flat on the bottom of the Distillation Tank as  shown    b  With thumb and index finger  squeeze the Retainer Ring and insert into inside of the Liner Bag  Let go  and make sure it fits securely in the groove    d  Fold the flap of the liner bag over the retainer ring     Caution  Ensure that the bag material does not block the Vapor Outlet        LINER BAG  VAPOR OUTLET  TAINER RETAINER RING  RETAINER RING INER BAG  Fold Down Lip  DISTILLATION                       D    NOTE  This is a schematic drawing only  not all components are exactly as shown     10  Inspect Lid Gasket  Remove and Replace if necessary as required    Inspect the Lid Gasket for shrinking  hardness and cuts  The Lid Gasket is a wear item as it is exposed to  high temperature and solvent vapor during distillation  Damage to the lid gasket will cause solvent to leak     To remove  open the Safety Cover and Tank Lid  Lift out the o
16. hrough the  brush       Open the lid        step on the right foot pedal  Clean solvent is delivered through the brush   Solvent flow through the rinse brush is limited to minimize clean solvent consumption     GRAVITY FEED SPRAY GUN       AIR CUP PRESSURE FEED SPRAY GUN    _ TRIGGER  J   LOCK SPRING          SYPHON FEED SPRAY GUN            TRIGGER    LOCK SPRING TRIGGER  LOCK SPRING         PAINT CU    PAINT CUP ADAPTER   NOZZLE  CENTERING  ADAPTER  NOZZL OPTIONAL SPRAY    SUCTION PIPE  NOZZLE NOZZLE       SPRAY JET    FILTER PAD       FILTER PAD       MANUAL   COMBO605 and COMBO655 Revision 2009 01    HOSE CLEANING            655 ONLY       Models with this feature        be used to clean a paint feeder hose up to 100 feet  30 m  long  Connect  the hose to the two fittings  one on the front and one on the right side  Rotate the    Mode Selector     handle to the horizontal position and turn the Timer knob clockwise to start the automatic cleaning  cycle        To air rinse the hose  push and hold the    Air Rinse    button        To rinse the hose with clean solvent  push and hold the     RINSE CYCLE CONTROL    button for about 5 seconds  This  will use about 100 cc of clean solvent  Wait 30 seconds for the  Rinse Pump to fully recharge before repeating         Disconnect the hose   FLOW CONTROLS  right side of unit     Two control levers on the right side of the unit allow the rinse sol   vent flow and the Brush solvent flow to be adjusted as needed  A  third lever allows
17. ld gasket by hand and clean the cavity with  a cloth  To Install  place the new gasket in the cavity  rub solvent or soapy water on the gasket to make  insertion easier  Press the gasket firmly into the cavity all around     Note  Keep a spare in stock  One extra is included with the unit   11  Transfer Recycled Solvent back to the CLEAN RINSE PAIL   Turn the knob of the CLEAN TRANSFER TIMER  bottom right  fully     CLEAN  TRANSFER  TIMER       10    MANUAL   COMBO605 and COMBO655 Revision 2009 01    THEORY OF OPERATION   DISTILLATION PROCESS  Waste solvent consists of the original solvent plus liquid and solid materials picked up during use of the  solvent  Recycling separates the original solvent from the waste materials  During the recycling process   the distillation tank fills with dirty solvent and the heating element heats the mixture  The solvent mixture  boils and the vapour passes through a cooling condenser where purified  clean solvent  ready for use  condenses out  Waste materials in the dirty solvent boil at a temperature substantially above the Tem   perature Set Point so they remain in the distillation tank for disposal     Solvent Recycling          Vapour Outlet tube   vapor moves  to cooling condenser    from distillation tank  Distillation  Tank  Condenser   cools vapor     Heating Element  to a liquid       Receiving Pail   contains clean   recycled solvent     11    Revision 2009 01    MANUAL   COMBO605        COMBO655    FLOW DIAGRAM   COMBO605         
18. le  Establish and follow safe practices to store and handle  solvents      Units must be installed by a qualified electrician and according to applicable laws     MANUAL             605                  655 Revision 2009 01    FEATURES AND SPECIFICATIONS    This unit combines into one cabinet the functions of a Uni ram UG6000E      UG60000EH Automatic Spray  Gun Cleaner and Uni ram URS500  120V  Solvent Recycler  All Uni ram Solvent Recyclers feature  rapid start direct electric heating of solvent and a short cool down time due to high efficiency condens   ers and air cooling with a motor driven fan     SAFETY FEATURES        The Solvent Recycler component is certified under UL standard 2208 and CSA standards   22 2        30 and No  88 for use in non hazardous locations as well as for use in hazardous locations Class  1  Division 1  Group D     T2C and Class 1  Division 2  Group D  T2C  The Gun Cleaner component   UG4000  is FM registered       Explosion proof construction  Recycler  and intrinsically safe electric circuitry      Computer controlled  Recycler  with many built in safety programs including temperature control  of all critical points including tank  condenser and fan motor       Self Diagnostic  Recycler  error messages are displayed on the Display Panel       Dual lid cover system  Recycler        Fume Vent  Gun Cleaner  for disposal of solvent fumes during gun cleaning     YES  YES  ES    LID GASKET   NEOPRENE      Y    Guns CLEANED fo o                    PU
19. lement   thermostat  wire conductor  blown  fuse  A defective thermostat or  wire terminal is the most likely  cause    2 TIMES  2 TIMES   Defective heater triac  Heater is  still              2 TIMES  3 TIMES   Condenser is overheating or ther   mostat is faulty     3 TIMES  1 TIME a  Boiling did not occur within 45  minutes  Tank is either empty or  there is excessive debris in liner  bag or tank is dirty           b  Set up point is too low         Boiling point of solvent is  above maximim set point     24 2 TIMES  4 TIMES   If code 23 condition lasts over 10  minutes  this code will show and  operation is terminated     16    Contact Uni Ram Service    Disconnect the power supply  immediately  Contact Uni Ram  Service    Clean dirty Condenser following  Service Procedure 1  If Ther   mostat is faulty contact Uni ram  Service    1  Clean dirty Condenser  See  Service Procedure 1    2  Position the unit to provide 6  inches  15cm  all around the unit   3  Check Cooling Fan or Fan Mo   tor     a  Clean Distillation Tank following  Operating Procedure 7  replace  liner bag  following Operating Pro   cedure 9     b  Increase temperature set point  following Operating Procedure 4  and recycle with virgin solvent    c  Solvent cannot be recycled        MANUAL   COMBO605        COMBO655    ERROR  CODE    Description    Flashing LED  Lights  READY   READY   L   H     3 TIMES   2 TIMES    Micro Controller has been reset  due to power interruption or drop  in voltage during the rec
20. nt and  repeat the recycling operation  The Tem   perature Set Point should be the BP of pure  solvent  as determined from the MSDS or  other source  plus 45  C  113  F  to allow for  contamination  If the boiing point is above  the maximum Temperature Set Point for  your model  200  C   dirty solvent cannot be  recycled in this unit        Liner Bag sticks Turn unit on for 5 mininutes and lift out bag  while it is still warm     14    MANUAL   COMBO605 and COMBO655 Revision 2009 01    PROBLEM CAUSE ACTION STEPS    Solvent vapor leaks from the Lid   1  Lid Gasket has 1  Replace the Lid Gasket  See Operating  Gasket excessive wear as Procedure 11     indicated by cracks    shrinkage  hardness    etc   blocked   adequate  seated correctly   4     The temperature 4  Reduce the Temperature Set Point and  SET PT too high  re  repeat the recycling operation  If success   sulting in excessively   ful  continue to recycle using the lower  high solvent vapour Temperature Set Point   pressure    Sections      Bag are brown and   1  Use of inferior low 1  Use new genuine Uni ram high tempera   thin due to High Temperature temperature bag  ture Liner Bag and recycle   2  Temperature Set 2  Reduce the Temperature Set Point and  Point is too high  repeat the recycling operation  If success     ful  continue to recycle using the lower  Temperature Set Point     The computer appears to be The computer may Disconnect the power supply for 30 sec   operating erratically  require re booting  ond
21. on preparation  use and operation to  operate this machine safely and effectively  Ensure that this manual is readily available to the operator at  all times  If you have any questions about the operation of this machine  contact     North America   Uni ram Technical Service  1 800 417  9133  Other Continents   Contact Your Supplier    CAUTIONS AND WARNINGS        The operator should wear protective clothing in accordance with local safety and environmental  regulations  with a minimum of face goggles and gloves along with an apron and respirator if required      Always disconnect the power source before performing maintenance      DONOT SMOKE OR USE THIS EQUIPMENT NEAR A POTENTIAL SOURCE OF IGNITION SUCH  AS SPARKS OR AN OPEN FLAME  This unit must be located at least 6 feet  1 8 m  from all potential  sources of ignition including electrical receptacles  switches  pilot lights  fixtures and contacts when  installed in a non   hazardous locations      The ambient temperature must be between 5  C  41  F  to 35  C  95  F       DONOT RECYCLE NITROCELLULOSE WHICH IS EXTREMELY VOLATILE  IT AUTOMATICALLY  IGNITES AT 135  C TO 166  C  275  F TO 330  F   Do not install  operate or maintain this equipment  where the auto ignition temperature of the solvent is lower than 250  C  482  F       Do not install  operate or maintain this equipment where the auto ignition temperature of the hazard   ous atmosphere s  is lower than 250  C  482  F     e Solvents that are recycled can be flammab
22. paint from the cup  when present  into a 5 gallon          not supplied      Rinse cup with solvent and pour into the same 5 gallon pail for later disposal or recycling     CLEANING SPRAY GUNS AND CUPS      Loosen the air cap of the spray gun two full turns    e Lock the trigger in the open position with the Trigger Lock Spring      Plug air inlet of spray gun with cap to prevent solvent from entering passage  Caps are supplied in the  accessory kit      Place spray guns facing corner jets  Placement depends on type of spray gun  See pictures below   Place cups onto the low spray jets and cup holders    Note re  Gravity Feed Spray Guns  Some customers prefer to clean the cup separate from the spray  gun      Close the lid and turn the  Auto Wash Timer  knob clockwise to start cleaning  The cleaning cycle  takes about 60 seconds     Push and hold the    Air Rinse    button for about    second to                   the guns      Push and hold the    Clean Rinse    button for about 5 seconds to rinse guns with clean solvent  This will  send a pre set amount of clean solvent  100 cc  through the jets  Wait 30 seconds for the Rinse Pump  to fully recharge before repeating    The solvent flow per clean rinse cycle is limited to 100 cc to minimize consumption  This quantity is  usually sufficient to clean the inside passages of the spray guns     USING THE MANUAL WASH and MANUAL RINSE FEATURES      Open the lid and step on the foot left pedal  A dedicated pump delivers wash solvent t
23. s  Restore power and operate unit   Residue  puck  in Tank is too 1  Not enough heat to   1  Raise the Temperature Set Point  wet  vapourize the solvent    2  Residue cannot be   2  None    dried completely due   to its composition        15    MANUAL   COMBO605        COMBO655 Revision 2009 01    ERROR CONDITION CODES    The computer constantly monitors the unit as it operates     AN ERROR CONDITION IS INDICATED BY FLASHING    READY    LIGHTS     NOTE  On later models of the URS500  due to a change in software  the heater light may flash  during normal operation  For all error conditions except for an error code    22    condition  the Heater light    would be off     To determine the error type  count the flashes of READY  L   before READY  H  flashes  then count the   number of flashes for READY  H    For example  two flashes from READY  L  and then one by READY   H  indicates error code 21  Look up the Error Code on the Chart below  Press the    OFF    button to stop  the error code and press the    ON    button to resume operation after the error condition has been correct     ed  If the error persists  call for service     Flashing LED  Lights  READY   READY   L   H     ERROR  CODE    Description    Action Required    11 1 TIME 1 TIME Open circuit   defective tank Contact Uni Ram Service  thermocouple   12 1 TIME 2 TIMES   Open circuit   defective condens    Contact Uni Ram Service  er thermocouple    2 TIMES   1 TIME Open Heater Circuit   defective  component  heater e
24. w out of the Solvent Receiving Pail into either a free standing  external container or the  Clean Solvent Pail of a Spray Gun Cleaner  The transfer will stop whwn the timer runs out     7  Remove Debris     Remove the Retainer Ring    Slowly pull the Liner Bag containing the debris out of the distillation tank in a way that the Liner Bag does  not break    Dispose of the debris in accordance with local regulations     NOTE  If the bag sticks to the bottom of the tank  turn the recycler on for 5 minutes to loosen the bag from  the bottom of the tank  then lift the bag out while the bag is warm     8  Clean Distillation Tank and Lid Surface  Distillation Tank     Wipe and dry tank with a cloth    Remove any remaining debris from the Distillation Tank using if necessary  plastic or wooden tools  Do  not clean with abrasive or hard metal instruments that can damage the tank  The warranty does not cover  such damage     Note  There will be about 1 8 Gal  500 ml  of solvent remaining in the Distillation Tank after recycling due  to condensation  This solvent  If left in the tank  can cause corrosion  Dirt and debris left in the tank can  prevent full heat from reaching the dirty solvent during recycling     Caution  Acidic or chlorinated solvents typically cause corrosion on an aluminum tank  It appears as  black pitting spots on the tank  Excessive pitting leads to an unsafe condition of holes in the walls of the  tank and solvent leakage  Inspect your tank after each batch  If th
25. ycling  operation     a  Recycling did not finish in 6  hours due to power interruption or  excessive debris in Liner Bag    3 TIMES   3 TIMES    b  Temperature Set Point is too  low for the solvent         Boiling point of solvent is  above maximim set point     17    Revision 2009 01    Action Required    Press    OFF    and then    ON    but   tons to resume operation  Discon   nect power at the source for about  30 seconds  Usually nothing is  wrong with the unit     a  Clean Distillation Tank following  Operating Procedure 7  replace  Liner Bag  following Operating  Procedure 9     b  increase Temperature Set Point  following Operating Procedure 4  and recycle with virgin solvent    c  Solvent cannot be recycled        MANUAL             605                  655 Revision 2009 01    SERVICE PROCEDURES    1  CLEAN CONDENSER  Using a brush attachment  vacuum the condenser at the back of the unit     2  CLEAR BLOCKED SOLVENT FLOW PATH    CAUTION  WEAR SAFETY GOGGLES     A blockage in the solvent flow path  Vapour Outlet   Condenser   Solvent Outlet Tube  can cause solvent  to leak  To determine the location of the blockage  first check the Solvent Outlet Tube and the Vapour  Outlet Fitting for visible signs of blockage or damage  If the problem is not in either of these locations  the  Condenser is problably blocked  To clear the condenser  pour some clean solvent into the Vapour Outlet  and check if it comes out of the Solvent Outlet Tube  If the blockage persists  blow air
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
User Manual - Sütron electronic GmbH  Bilan du Plan Climat territorial 2006-2011  User Manual  Microlife MT 300 Navigation Manual  manual de usuario de el radio digital a manivela para alertas  Desa 110946-01 User's Manual  D7100 A&E - Interlogix  Reconnaître et valoriser les intelligences multiples dans votre classe  choosing the right baby gear  Samsung NX5 دليل المستخدم    Copyright © All rights reserved. 