1. Ontrac Remote Management Operators Manual Ontrac Satellite Plus To Make The Most of Your 24 Hours MORE RIGHT THAN RAIN Reinke 6 Table of Contents DOV SCCM SOEGU SOE E N A E 1 2 Ontrac Satellite Plus ata GlanCe sscsecccccssccecsoseccccssseccocssssecossssccesssssecesossesessssse 3 4 Gee a a E E E aa 5 PANO UTS AUN Lene EEE E O ASEEN E 6 On AC WV CO 7 14 How to Log into ecce eee e e 7 uiu 8 Summary Site Detalls cens esta eas esto vene aeneo n ER eU 9 Summary SESC 10 summary Site Notes and 11 and Report Page sssecsssccsssecssccssscessseesssecsssecsssessssesssseoo 12 My ig POMC 13 Farm Notes Contact Help and Logout 14 PIEI i E c 15 1 System Safety gt When towing a System from field to field avoid ditches rough terrain overhead power lines etc The Ground Wire MUST be re attached to the Ground Rod and checked for electrical integrity each time the System is towed Avoid any bo
2. clicking on site ivr or current status blue text headers changes the order in which this information 1s displayed on this page and by clicking on the blue text within the columns takes the user to more pages that show further detail of each system as shown on the next few pages Ontrac User Manual 8 ONTRAC 5 3 Summary Site Details Below is an example ofa page the user will see by clicking on one particular pivot system MORE FIGHT THAN RAIN ONT RAC Reinke 5 22 10 06a summary map reports my profile farm notes contact help logout setup site notes control a current position 41 current status 5 last report about 14 hours ago speed stopped wet run days 45 9 crop corn forward 16 6 revolutions YTD ac in applied 17 85 variety Hybrid reverse 16 6 revolutions YTD rainfall 2012 4 00 plant date 04 05 12 view graph total 21 85 desired finish date 01 01 12 view history irr week 2 68 desired finish ac in 0 Proj finish ac in 0 yield 0 based on last speed and direction bu ac in not set of 41 reported 5 21 8 05p YTD PIVOT SUMMARY WATER PRESSURE 2 WEEK a Bl psi click for more detail down BH dry wet 30 25 a 20 9 15 10 5 9 Apr May Jun Jul Aug Oct Nov Dec Jan Feb Mar Apr May NOUA 05 08 2013 05 10 2013 05 12 2013 05 14 2013 05 16 2013 05 18 2013 05 20 2013 On this page the screens visible can
3. to open the control page for the unit This control page will allow you to select commands and execute now on a schedule or by position Simply check the box next to your desired command and click on the desired execute button Every command should be followed by a confirmation message If a failure happens try one more command before calling the dealer for support Last Reported Status 5 30 Pivot off Direction forward 83 0 Flow 0 0 gpm Pressure 0 4 Safety Safety OK i Pressure Switch ON 4 Pump OFF BE Chem OFF EndGun Auxi OFF Park Position 0 0 Last Report Position 41 9 Degrees C 96 9 5 E 5 30 update no commands being processed right now Command Options Start Park Endgun execute on schedule Jan 1 m 1 11 Stop O Speed Unpark Set ON OFF cancel scheduled command degrees site ivr Sat 11 amp 0 Sat Advanced 12 0 show hide status code help Sat Touch 22 status psi GPS control 22 summary map reports my profile farm notes summary for Reinke Sales wet run 24hr hours rain 2 8406 152 19 us A 539 6 viewing data starting January 0 0 00 Control Pa 1 05 26 Google 1 05 26a 1 Stop Unpark percent Forward ON ON ON ON Direction degrees Eu D 3 execute now execute on schedule execute on pos
4. 9 9 125 850 90 116 140 1 1 2012 12 1 2012 Sat Touch Sata Touch 300 90 0 0 5 16 2013 5 24 2013 link to set up area for each pivot parameters graph monthly irrigation summary list every status change start report January 2012 finish report December 2012 12 Ontrac Owners Manual ONTRAC A 8 Pro file This is where the user changes User Name Login Name Password Time Message Options and Pager Options ONTRAC Reinke MORE FIGHT THAN RAIN summary map reports my profile farm notes contact help logout nies 10388 Reinke Sales options login 14193 password select your current time 5 22 10 30 this will set your time zone for paging options message options alert for pivot direction changes alert for pivot direction changes at night alert for on off power cycles optional alert for on off power cycles at night view times in hours instead of days drop decimal points on summary page do not send speed change pages at night night time refers to the hours from 10pm to check to enable myfarmemail email com employeel gemail com employee2 email net Message Options When checked these allow the user to control some of the messages received and when If not checked the option is not active Pager Options This allows the user to be in control of personnel who will receive messages
5. at time of installation or if any additional options are added at a later time Email Alert oent Tuesday May 21 2013 2 33 PM To Farm Email Field 1 SW gt S 0 1h 214 0 0 Site Name Current GPS Location Status Last Duration of Current System Status Last Status Water Pressure Text Alert Field 1 SW gt S 0 1h 214 0 0 Site Name Current GPS Location Status Last Duration of Current System Status Last Status Water Pressure 4 1 Legend Below is the legend that will help you understand the above messages Stopped Wet S Stopped d Running Dry in Forward w Running Wet in Forward D Running Dry in Reverse W Running Wet in Reverse x Unit not reporting or power off to unit p Power fail Ontrac Owners Manual 6 5 Ontrac Website 5 1 How to Log into the Ontrac website Make sure you have your username and password handy that you created during activation 1 Go to www ontracbyreinke com p Type in your username in the text box provided on the screen 3 Type in your password in the text box provided on the screen 4 Click when finished and you ll enter your Ontrac website If you check the remember me box the next time you go to the website it will automatically remember your login name and password Please use caution when using the remember me option as this will allow access to any one using your phone ONTRAC ONTRAC subscr
6. bsite The user should always do this when finished working on the website to insure privacy Ontrac Owners Manual 14 ONTRAC Before attempting any service or installation work ensure the Disconnect Switch on the Main Control Panel is OFF 6 System Maintenance Year End Winterization a Disconnect the battery from the electronic board b Remove the battery from the unit if winter temperatures reach 32 Fahrenheit or lower c Store battery above 32 degrees Fahrenheit to help preserve battery life also if system will be idle for more than a 2 month period 15 Ontrac Owners Manual ONTRAC Satellite Technology Perfect for areas with little or no cellular coverage Equipment Compatibility Provides the most advanced satellite remote monitoring and control on Reinke s RPM and Touchscreen panels Economic Value Ontrac Satellite Plus will provide years of reliable monitoring and control and the performance the user is looking for at an affordable cost of ownership Create reports control your system or view extensive history via the internet Control your system via tablet smart phone or any secure internet connection
7. dily contact with high pressure water streams from Sprinklers and End Guns Keep away from fields where the System is chemigating Make sure the applied chemical and water does not blow or drift past the area of intended operation A Check Valve must be installed between the Pivot Center and the Pump to prevent the mixture of water and chemical from siphoning back into the irrigation water source Comply with all local state and federal regulations Do not oversize Fuses Fuses are sized for a A specific circuit It is very important to make sure you have the proper fuse size in place before initially starting the System and when replacing Fuses Do not operate System when temperatures are below 40 F 4 5 C This can cause structural damage to the System Ontrac Owners Manual In most states it is unlawful to spray water on state and county roadways This is a serious hazard and must not be allowed If your System is equipped with any Auto Stop or Auto Reverse Mechanism make sure they are working correctly and a Tower Barricade is properly installed as per this manual Reinke disclaims any and all liability including any liability created pursuant to the Irrigation Systems Warranty with regard to damage to the Irrigation System or to other property or personal injury or death caused by improper installation or maintenance of Reinke supplied Tower Auto Reverse or Auto Stop Switches Tower Barricades or by us
8. e of customer supplied Barricades Driveshafts may start without warning Keep away from Driveshafts to prevent clothing or limbs from being entangled resulting in severe injury Do not endanger your own life and possibly the lives of others by being negligent Be aware that the system may start automatically depending on how your system is setup monitored and controlled The Reinke Electrogator II System is designed with many electrical and mechanical safety features However each operator must read and understand this and all other accompanying owners manuals for the safe and efficient operation of your Reinke Electrogator II System If this System is operated incorrectly it can pose a safety threat to the operator and others The following is a list of safety operating tips which all service and operating personnel must read and understand A The Safety Alert Symbol is displayed many places throughout this manual and on your System to indicate when there is a potential for Personal injury A Throughout this manual and on System Decals the words DANGER WARNING and CAUTION are used with the Safety Alert Symbol to alert the operator of potential hazards DANGER identifies the most serious hazards DANGER or WARNING safety signs identify specific hazards CAUTION signs identify specific safety instructions The movement of an Electrically Powered Gear Driven I
9. from the system deselecting a phone number name deactivates the phone number person from receiving messages 13 Ontrac Owners Manual ONTRAC 5 9 Farm Notes Usercan put any notes pertaining to any system for future reference 5 10 Contact With this popup screen user can get help line phone numbers or email help desk To Contact Ontrac Please call the number below or fill out the email form Messaging setup options Reinke customer care 888 872 2360 name email phone 511 This 1s a popup screen where the user get the description of each tab located on the summary page summary This page is designed to give you a quick run down of what the most important numbers are The following Is a page description of each of the columns site Your name for your pivot compressor pump dryer or whatever you are monitoring current F tabu The last known status of your site time days The amount of time that your site has been in the current status prior pu The last known status before the current one The number of days that we record your site as running Optional pressure If you have a pressure transducer installed this is where we would give you your current pressure reading in psi If you have an electronic flow meter installed and being read this is where you would see your average flow flow reading Close Window 5 12 Logout This is where the user logs out of the we
10. he critical system alerts this product offers 3 Ontrac Owners Manual ONTRAC 2 2 Main Control Panel Installation Installatton RPM Advanced and Touch Compatible Satellite Plus unit is installed inside inside the panel Antenna Connection a ue Ontrac Satellite Plus base unit CPU Connection Battery Connection Bracket and Antenna Mount Ontrac Owners Manual ONTRAC 3 Getting Started Activation To activate the wireless service plan you need e wireless services agreement provided by an authorized Reinke dealer The Reinke dealer can help you successfully activate your Ontrac Satellite Plus device To use Ontrac Satellite Plus with your phone you need To enable text messaging with your cell phone provider and or enable internet access on compatible devices To use Ontrac Satellite Plus with your computer tablet or smartphone you need nternet Access and at least one of the following internet browsers Internet Explorer 9 or greater Firefox 11 Google Chrome 26x Your username and password and passcode provided at time of activation Record your account information below Account Name Username Password 5 Digit Passcode satellite Plus Modem Number Field Location Ontrac Owners Manual ONTRAC 4 Alerts U You can receive system alerts through email and or text messaging These alerts are based on the device configuration
11. ibers log in here login name 1 password 4 remember me 3 contact 7 Ontrac Owners Manual 5 2 Summary Page Reinke Summary map reports my profile farm notes contact help logout 5 22 8 45a summary for Reinke Sales gt wet r 24hr site ivr status psi GPS control h s ours rain Sat 11 o control 840 6 Sat Advanced 12 o O 41 9 control 1102 5 Sat Touch 22 amp 0 152 1 control 539 6 0 00 show hide status code help viewing data starting January 01 2013 change Scan this QR code to your phone and open the link to your mobile website amp PivoTrac Monitoring Dalhart Texas A Summary Page Lists all systems being monitored All blue purple text are links to other pages site ivr Unique name of pivot Current Status Displays current status of your system with both a symbol as well as a 1 or 2 letter code psi When a pressure transducer 15 used this shows actual system pressure GPS This shows the location of the system in degrees control Depending on how the unit 1s equipped This will allow you to do functions such as stop stop by position notify on position and set a daily schedule wet run hours Total hours the pivot has ran wet with water since the viewing data starting date at the bottom 24h rain The amount of rain that has fallen in the last 24 hours if this option 1s installed on the device By
12. ition 1AM 1 Ontrac Owners Manual Satellite 5 30 Last Reported Status 5 29 11 55 14p Pivot on Direction forward 190 0 Flow 5376 0 gpm Pressure 201 6 Safety Safety OK Pressure Switch OFF Pump OFF Chem OFF EndGun OFF Auxi OFF Park Position 0 0 Last Report Position 330 1 Degrees 1 35 50 update o commands being processed right now ommand Options Speed percent Set degrees Reverse OFF OFF OFF OFF Jan 1 1 1 1 degrees ONTRAC 5 6 Map Page Shows topical map of your area and locations of your systems this tab also gives the user the ability to save different maps and locations 4 2s s ONTRAC Reinke 3 O MORE FXSHT THAN BAIN 5 22 10 25 summary map reports profile farm notes contact logout e save map location 5 7 Report Page Clicking on run report produces a pdf file that could be saved gt ONTRAC Reinke i MORE RIGHT THAN RAIN LI a 5 22 10 27 summary reports my profile farm notes contact help logout select parameters for report select sites m site statistics check all heck nii site legal wet total rain rain name name owe eff acres acres start finish L Sat Sat T2352R1 450 90 42 55 1 1 2009 1 1 2009 M 5 Advanced Sat Advanced 3
13. rrigation System is relatively slow Moving parts are exposed and may present a potential hazard Therefore keep all equipment vehicles people etc out of the System s path A DO NOT attempt to perform any maintenance procedures until the Main Control Panel Disconnect Switch and all Pump and other Disconnect Switches are locked in the OFF position Electrical component trouble shooting and replacement should be performed by a certified Service Technician to ensure built in safety features remain intact This also ensures System remains compliant with the National Electric Code and the Manufacturers Specifications Replace all Protective Guards and Shields before restoring power to the System A Do not allow anyone to ride or climb on the System unless they are qualified and required to do so for maintenance purposes The Tower Steps have been provided for access to the Tower Control Boxes only They are not intended for access to the Span For instance should the Sprinkler Heads require service use a ladder to reach them from the ground Exercise caution when handling fuel near Systems equipped with Combustion Engine driven Generators and Pumps A If you attempt to repair your System and are uncertain of your methods contact an authorized Service Person A Keep away from the System during thunderstorms or other severe weather conditions The Center Pivot is grounded and the System is probably the highest object in
14. the field making ita good lightning receptor A Be sure Protective Guards are installed on all Belts and Driveshafts of Ancillary Equipment such as Combustion Engines Electric Motors Pumps etc A If you suspect a short circuit or the System is not working correctly do not touch the System and keep others away from it Call your Service Technician Electrical component trouble shooting and replacement should be performed by a certified Service Technician to ensure built in safety features remain intact This also ensures System remains compliant with the National Electric Code and the Manufacturers Specifications Ontrac Owners Manual 2 2 Ontrac Satellite Plus at a Glance Ontrac Satellite Plus base unit Din Rail Release w CPU Connection Connection v tto B if me UIT 57 Power Supply b y vM e alg Input 4 7 E 2 2010 Antenna Connector Satellite 2 1 How it works Modem The Ontrac Satellite Plus communicates through a satellite network to an Ontrac server where the data is stored This information is displayed on your website for monitoring and control of your irrigation system You can access the secure website anytime anywhere using any internet enabled device such as tablets smartphones laptops and desktop computers Ontrac Satellite Plus can easily keep you in touch with you and your irrigation systems through t
15. vary in number and content depending upon the options installed on each system Ontrac Owners Manual ONTRAC 5 4 Summary Site Setup By clicking on the setup site notes and control tabs of the details screen the user will go into even further detail as shown next The headers will show path to screen shown ONTRAC Reinke MORE RIGHT THAN BAIN contact help logout 5 22 10 12 farm notes summary map reports my profile editing stats for Reinke Sales Sat Advanced farm stats legal description 39N9E128 help total acres 0 help wet acres 6 pivot efficiency 90 e help flow rate gpm 850 help crop corn help variety Hybrid 2 population 800 plant date 5 v 2012 help finish date 1 January gt 2012 help finish acre in 0 help yield oO help rain rain adder 4 1 help start rain at Jan 1 help rain start 1 e January 2012 help rain finish 1 December 2012 help Save 10 Ontrac Owners Manual ONTRAC 5 5 Summary Site Notes ONTRAC ud summary map reports my profile 10 1 12 Rained 5 farm notes contact help logout farm notes Add your notes for the system here Reinke O RIGHT THAN 5 22 10 15a Summary Site Control From the summary page you can click on control