Home

Dual Levelar Owner`s Manual

image

Contents

1. very mild and musical compression ratio which is ideal for smoothing all types of signals In its in position the Dual Levelar s compression ratio is greater than 6 1 This is typically called soft limiting as it allows only a 1dB change in signal level for any signal reaching over 6dB over the set threshold This setting is ideal for applications where exceeding a set level is not desirable mixing popping bass etc Auto Fast Switch The position of the Auto Fast switch selects the release characteristics of the Dual Levelar The out position allows the Dual Levelar to recover quickly once the signal falls below the threshold The in position allows the Dual Levelar to adjust itself depending on the characteristics of the signal being processed sometimes called program dependent Use the fast setting when the signal has repetitive consistent characteristics kick drum snare vocals etc Use the auto setting when the signal has varying characteristics long decaying notes alternating with quick notes mix material etc Output Control The Output control sets the output gain of the Dual Levelar When the control is fully counterclockwise the output level of the Dual Levelar is attenuated by 83dB off Turning the control clockwise adds gain sometimes called make up gain Since levels can be decreased when compression is applied the Dual Levelar has the ability to 5 ap
2. A R T APPLIED RESEARCH AND TECHNOLOGY DUAL LEVELAR Two Channel Tube Compressor Leveling Amplifier USER S GUIDE Introduction Thank you for purchasing the Dual Levelar and congratula tions You now own one of the most sophisticated pieces of audio signal processing gear available Similar in design philosophy to classic tube limiters the Dual Levelar utilizes a VCA less design for premium musical performance This design features electro optical Vactrol and vacuum tube electronics which deliver classic sound without the old noise Features Two channel tube and Vactrol based Leveling Amplifier Stereo linking of channels Hand selected 12AX7 Tubes Vactrol Optical electronic isolators Non VCA design transparent classic sound Balanced XLR and 1 4 TRS inputs Balanced XLR and 1 4 TRS outputs Limiting and Compression ratios Auto or Fast release characteristics Variable Threshold rotary controls Variable Output level rotary controls Gain reduction LED ladder 10Hz to 20kHz Frequency Response gt 100dB Dynamic Range Extremely low noise All steel construction Designed and manufactured in the USA Fill in the following for your future reference Date of purchase Purchased From Serial Number 256 _ This a great time to fill out the User Registration card included with your Dual Levelar to become a completely informed A R T Artist Returning the card to us ensures you of becoming the first
3. e Dual Levelar to achieve the desired amount of compression AR T Dual Levelar Specifications Dimensions 19 W X 6 50 D X 1 75 H Weight 5 5 Lbs Input Connections balanced XLR amp 1 4 TRS Output Connections balanced XLR amp 1 4 TRS Input Impedance XLR 1 4 20K ohms 1M ohms Output Impedance XLR 1 4 600 ohm 300 ohms Maximum Input Level XLR 15dBm Maximum Input Level 1 4 15dBm Maximum Output Level XLR 26dBm Maximum Output Level 1 4 20dBm Frequency Response 10Hz to 20KHz 5dB Dynamic Range gt 105dB 20 20kHz THD OdB out lt 0 1 typical Equivalent Input Noise EIN XLR to XLR 100dBm A weighted 1 4 to 1 4 100dBm A weighted Attack Time 6 5ms Release Time Fast 200ms Auto 70ms 1sec Slope Comp 2 3 1 Limit gt 6 1 Max Attenuation 28dB Power Requirements 95 125VAC 10 W USA Internal fuse Other power requirements configured for country of destination ART retains a policy of constant product improvement therefore specifications are subject to change without notice A R T reserves the right to make changes in design or make additions to or improvements upon this product without any obligation to install the same on products pre viously manufactured We re Online For Product information questions applications tips answers and general discussion with A R T employees look for A R T on the Internet Check out our Web Page at http www artroch com
4. e this warm up period is over Threshold Control The Threshold control sets the point at which the Dual Levelar will act on a signal Turning this control counter clockwise lowers the threshold adding more compression to a signal Turning this control clockwise raises the threshold Setting the Threshold control is dependent on the input signal The output from a guitar might be 20dB to 10dB where the level from an insert on a console might be 10dB to 10dB The easiest way to set the threshold control is to start with the control fully clockwise Slowly turn the con trol counter clockwise lowering threshold until you see the Threshold LED light Now adjust the control either lower or higher until you have the amount of compression you desire Active Bypass Switch The Active Bypass switch must be pressed in for the Dual Levelar to process a signal In its out position the Dual Levelar is bypassed and signal runs from the input jacks to 4 the output jacks with no processing Use the Active Bypass switch when setting the Dual Levelar s output level to achieve unity no boost or cut gain Unity gain is achieved when the active level is the same as the bypassed level Limit Comp Switch In its out position the Dual Levelar s compression ratio is an active 2 3 1 ratio This means that for every 2 3dB over the threshold the input signal rises the Dual Levelar s out put will change by 1dB This is a
5. email artroch aol com Warranty amp Service Information Limited Warranty Warranty service for this unit will be provided by Applied Research amp Technology Inc in accordance with the follow ing warrant statement Applied Research amp Technology Inc A R T warrants to the original purchaser that this product and the compo nents thereof will be free from defects in workmanship and materials for a period of three years from the date of pur chase Applied Research amp Technology Inc will without charge repair or replace at its option defective product or component parts upon prepaid delivery to the factory ser vice department or authorized service center accompanied by proof of purchase date in the form of a valid sales receipt EXCLUSIONS This warranty does not apply in the event of misuse or abuse of the product or as a result of unautho rized alterations or repairs This warranty is void if the seri al number is altered defaced or removed ART reserves the right to make changes in design or make additions to or improvements upon this product without any obligation to install the same on products previously manufactured ART shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some states do not allow limitation of incidental or consequential damages so the above limitation or exclu sion may not apply to you This warranty gives you specific ri
6. ghts and you may also have other rights which vary from state to state For units purchased outside the United States service will be provided by an authorized distributor of Applied Research and Technology Inc 8 Service The following information is provided in the unlikely event that your unit requires service 1 Be sure that the unit is the cause of the problem Check to make sure the unit has power supplied all cables are connected correctly and the cables themselves are in work ing condition 2 If you find the unit to be at fault write down a complete description of the problem including how and when the problem occurs Please write down a description of your complete setup before calling Customer Service 3 Call our Customer Service department for a Return Authorization RA number or questions regarding techni cal assistance Customer Service hours are 9 00am to 6 00pm Eastern Time Monday through Friday 4 Pack the unit in its original carton or a reasonable substi tute The packing box is not recommended for a shipping carton Put the packaged unit in another box for shipping Print the RA number clearly on the outside of the shipping box Print your return shipping address on the outside of the box 5 Include with your unit a return shipping address we cannot ship to a P O Box a copy of your purchase receipt a daytime phone number and a description of the prob lem Keep your manual 6 Ship y
7. ive balanced You may use it in an unbalanced configuration without harm to the output circuitry Use the unbalanced 1 4 jack for send ing your signal to amps processors or other unbalanced configurations Use the XLR output to send signals to equipment which accepts XLR connections Both outputs may be used at the same time Note If you experience a grounding hum when using both output connectors one to the console one to an instrument amp simultaneously a ground loop may be the problem To remedy this problem disconnect lift the ground wire pin 1 from the XLR cable plugged into the Dual Levelar s output This interrupts the ground path and therefore breaks the loop Controls Switches and Indicators Power The Dual Levelar is powered by an internal power supply The Power switch and indicator LED are located on the front panel If the attached power cord ever becomes dam aged discontinue use until you can have it repaired or replaced Like all tube equipment the Dual Levelar must be allowed to warm up before use Upon power up you will see all the LEDs light then turn off This is normal and the Dual Levelar is ready for use once the LEDs have turned off The 12ax7 tubes will reach normal operating temperature with in one to three minutes During this warm up period you may experience variations due to the THD of the tubes stabilizing Again this is nor mal and the Dual Levelar will provide consistent results onc
8. our unit to APPLIED RESEARCH AND TECHNOLOGY INC 215 TREMONT STREET ROCHESTER NEW YORK 14608 ATTN REPAIR DEPARTMENT
9. ply gain to bring the processed signal back up to unity same as input level To properly set the output level adjust the control while switching between Active and Bypass When these two levels are equal in volume the out put control is set properly Gain Reduction Meter The four LED meter is provided to give a visual indication of how much compression is taking place The Threshold LED will light when the input signal reaches the set thresh old level The remaining three LEDs indicate how much the signal is being compressed Their values are 3dB 6dB and 12dB Applications Compressor limiter The main application of the Dual Levelar is to control the dynamic range of a signal level Plug a line level post pre amplifier or other gain stage source into either input and set the threshold and output controls to provide the desired amount of compression to the input signal Stereo mix and mastering Because of its low noise and excellent tonal qualities the Dual Levelar is ideal for running mixes through before recording to DAT or cassette Used as a mastering device the Dual Levelar is capable of adding warmth and impact to the overall signal level Vocal and instrument levelling The musical nature of the Dual Levelar makes it ideal for use on a wide range of instruments and vocals Place the Dual Levelar into a channel insert after a preamplifier or from a direct output of a channel of a mixer Adjust the controls of th
10. to know about new A R T products as well as any further developments from A R T 1 256 5004 101 Overview Compression is used to alter the dynamic range of a signal In recording and live sound situations compression and limiting is necessary to manage sounds with wide dynamic ranges Dynamic Range is measured as the difference between the loudest and softest level of a signal i e from a scream to a whisper Once a signal rises above or falls below the set threshold selectable signal level the com pressor automatically changes its gain to raise or lower the overall signal level Think of this as manually moving a fader up and down to try to keep a signal at a consistent level Limiting can be described as a ceiling When using a lim iter once the signal level reaches the threshold it is unable to go any louder it is limited to a desired level In addition to making signal levels more manageable it is common practice to apply compression or limiting to a sig nal to make it louder or more in your face The benefit of using the Dual Levelar for these applications is in its design By utilizing opto electronics the Dual Levelar allows you to add more compression without sounding like you re squashing the daylights out of the signal Unlike typi cal compressors that use VCA s to control level detection the Dual Levelar is very musical The nature of its operation is much like the way your eye adjusts to light J
11. ust as your eye transparently adjusts to changes in light the Dual Levelar adjusts to changes in signal level Connections It s easy to interface the Dual Levelar with other equipment All connections are made at the back of the Dual Levelar Standard XLR and 1 4 inputs and outputs make patching simple Note for best audio quality always use high quality cables Inputs The Dual Levelar provides both an XLR and 1 4 input jack Both jacks are balanced The 1 4 jack can be used with 2 unbalanced signals by simply plugging in an unbalanced cable The inputs are designed for use with line level sig nals ranging from 30dBm to 15dBm While it is possible to plug an instru ment directly into the Dual Levelar it is desirable to run the instrument into a preamp before the signal runs into the Dual Levelar This will provide a stronger signal and will keep noise to a minimum Microphones must be run into a microphone preamplifier like A R T s Tube MP before being run into the Dual Levelar Use the XLR input for use with equipment that provides an XLR output like the Tube MP Use the 1 4 input jack for balanced or unbalanced 1 4 applications XLR pin configuration pin 1 Ground pin 2 Positive hot pin 3 Negative cold The 1 4 TRS configuration is Tip Positive hot Ring Negative cold Sleeve Ground Do not use both inputs at the same time Outputs The outputs of the Dual Levelar are act

Download Pdf Manuals

image

Related Search

Related Contents

Dehumidifier Service and Parts Manual  POP-K ORN, LA COMMUNICA TION AL TERN A TIVE - EUR  Blood pressure monitor Instruction manual ....................2  Girasol ring sling  Manuel d`instructions des Agents de saisie  MANUEL DE L`UTILISATEUR  ATA Nº 06, DE 09 DE MARÇO DE 1999  Agilent Technologies 6625A Power Supply User Manual    Ouvrir le fichier PDF - North Star Conditioning  

Copyright © All rights reserved.
Failed to retrieve file