Home
4 - Tyco
Contents
1. ICES 003 NMB 003 class A Europe EN55022 class A EN50130 4 Australia AS NZS CISPR22 New Zealand Compiles with European directive 2002 95 EC 42 ADST E1 Single Channel Video Encoder
2. EMNTED Sa Products Figure 3 4 Login Page English Select the appropriate language English and Chinese are available Enter the User Login Name in the Username field and password in the Password field Click Enter to open Web page in the language selected The web page varies according to the access right of the user Note For Administrator the default username password is admin admin for operator the default username password is operator operator for viewer the default username password is viewer viewer ADST E1 Single Channel Video Encoder Pre Web Configuration Log out from the ADST E1 Web Page Click the Logout button on the top right of the screen to logout Default Language Configuration You can change the default language for ADST E1 in the Web Configuration page The languages supported are e English e Chinese In any Web page of the ADST E1 click the Chinese or English on the top right of the screen to change the Web page with the language selected Web Page Introduction ADST E1 Web page is as shown in Figure 3 5 Click any of the menu entries to open the appropriate configuration page Per Tr A i e j pen al A o Pi a ere El Figure 3 5 Web Page The hierarchical structure of the Menu is shown in Table 3 6 Menu Navigation S American Dynamics 15 Pre Web Configuration Table 3 6 Menu Navigation Main Menu Live Video Video amp Audio Alarm
3. E Rm m Dos Eo 3 Hear Panel eer 4 Connector Pin Definitions cce 4 Interface Connection llle 5 Package Contents 5 Installation Installation Method A Pre configuration llle 8 Installation Method B Post installation configuration o o oooooo 9 e American Dynamics Pre Web Configuration QuickTime Settings Optional llle 11 Users Introduction soa eee ERG PGGURR 08864 EEG RE REG EEG EG Red RR 13 Login amp Logout oooooo ers 13 Login to the ADST E1 Web Page 13 Log out from the ADST E1 Web Page 15 Default Language Configuration LL 15 Web Page Introduction Li 15 Web Configuration EVER RR RETE 17 Configuring Image Parameters llle 17 JA EE a ere dete A 18 Stop amp MUte LL 19 AA TREE oo EA 19 Video G AU iena 20 OSD Configuration 20 Audio Parameters Configuration llle 21 Video H264 Configuration LL 22 VIGGO MJ eO asar es pe aa sao ida Pu EHI piedra 23 PUVACVINIASK ETT T EET T TTE TTE TITLE 24 Alarm Configuration o 25 External Input Configuration LL 25 Trigger amp Action Configuration 26 Network Settings 27 IP Address Configuration LL 27 RTP 8 RTSP Configuration LL 28 PTZ Parameters Configuration LL 29 Storage Configuration 2 hn nns 30 Recording Management 00 eee ee ees 30 Disk Management 31 System GCONMMQUIATION s s aasi e sensed ed qr tno
4. Post installation configuration Remove the ADST E1 from the packaging Refer to the Quick Start Guide to connect the ADST E1 to the network and then connect the analog Video source PTZ control cable if dome U disk or SD card Alarm In Out and power cable if PoE not supported Refer to chapter 4 Web configuration and configure the following settings on the IP Encoder Real time Browse PTZ Control Only Dome Video Audio Storage Alarm Network System Using the America Dynamics Video Edge Server Installation and and User Manual configure any other advanced features for ADST E1 Note When using installation method B only the ADST E1 with the default settings should be powered up and added to the network at a time e ATETEA Lnarrucs Installation 10 ADST E1 Single Channel Video Encoder Pre Web Configuration ADST E1 video encoder has built in Web service for customers to manage and maintain device through Web page At this release the supported web browsers are as follows e Microsoft Internet Explorer 6 x Microsoft Internet Explorer 7 x e Microsoft Internet Explorer 8 x At this release the supported operating systems are as follows e Microsoft Windows 7 e Microsoft Windows XP Professional Note You must first install QuickTime for viewing live video normally QuickTime Settings Optional If the IP of client computer doesn t belong to the same network as that of the ADST E1 configure QuickTime
5. RS 4223 A COM1 RELAYO1 Rx RS 4224 B OUT1 RELAYO1 SENSORNET HT 4 ADST E1 Single Channel Video Encoder Introduction COMO RELAY02 B6 SENSORNET LO Table 1 5 RS232 Pins Definitions Noises CI 08 ooo o RT Note Interface Connection The following is interface connection diagram The interface and the associated devices need connecting are as per site requirements from customers Package Contents e 1 ADST E1 single channel video encoder e 1 set installation accessories including install bracket 2pcs M3 screws 8pcs terminal block 2pcs e 1 Quick Start Guide S Amencon Dyriarmics 5 Introduction 6 ADST E1 Single Channel Video Encoder Installation The ADST E1 video encoder can be rack mounted jack mounted or desk mounted The method of installing the ADST E1 video encoder will vary depending on the type of its working models i e Power over Ethernet PoE or Power Supply PS and the network configuration of the installation environment The two standard methods of installing the ADST E1 are e Method A Pre configuration of ADST E1 Pre configuration of ADST E1 occurs before physical installation to the network This method is suited to larger installations where a number of ADST E1 video encoders are to be installed on the same site at the same time In this case the ADST E1 should be configured so as to have their own network settings and identification which provides Victo
6. XXX XXX XXX Enter the Gateway IP in the format xxx XXX XXX XXX Click Apply to enable the settings activated Click Restore to default to restore default settings O O N O I A Restart the device to activate the settings refer to Maintenance RTP amp RTSP Configuration Procedure 4 13 To Configure RTP amp RTSP Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page 28 ADST E1 Single Channel Video Encoder Web Configuration 2 Select Network RTP amp RTSP from the Web Main Page to pop up a configuration subpage of RTP RTSP on the right as shown in Figure 4 14 RTP amp RTSP RTF Port Enni RTS Port LA Mulikastit Er E FE F Address Malticast Port COGI Willie al Enabln Disable Rie to detti A Figure 4 14 RTP amp RTSP Table 4 11 Fields Explanations Field Button Explanation RTP Port to set RTP port RTSP Port to set RTSP port Multicast IP Address to set multicast address Multicast Port to set multicast port Open Close to open close multicast 3 Click Apply to enable the settings activated or click Restore to default to restore default settings 4 Restart the device to activate the settings refer to Maintenance PTZ Parameters Configuration For operating PTZ first properly configure parameters for it Procedure 4 14 To Configure PTZ Parameters Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page 2 Select PTZ from t
7. disable time display 4 Select Enable of Enable Text radio box to display text and type the text content in the Text field Select Disable of Enable Text radio box disable text display 5 Select OSD align formate from the Align Format drop down list The available value is Top and Bottom 6 Click Apply to enable the settings activated or click Restore to default to restore default settings End Audio Parameters Configuration Procedure 4 6 To Configure Audio Parameters Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page FrTwme mm Lnarrucs 21 Web Configuration 2 Select Video amp Audio Audio from the Web Main Page to pop up a configuration subpage Audio on the right as shown in Figure 4 6 Audio Video amp Audio 7 Audio Codec 5 711 Micphone 100 m volume Speaker volume 100 Ea AORTO naf iH Figure 4 6 Audio Table 4 8 Audio Parameter Explaination Parameter Range Explanation Codec G 711 To display the name of audio stream Read only Input Volume 0 100 To set volume for input audio The default is 50 Output Volume 0 100 To set volume for output audio The default is 50 3 Click Apply to enable the settings activated or click Restore to default to restore default settings Video H264 Configuration Procedure 4 7 To Configure Video H264 Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page 22 ADST E
8. 1 Single Channel Video Encoder Web Configuration 2 Select Video amp Audio Audio from the Web Main Page to pop up a configuration subpage of Video H264 on the right as shown in Figure 4 7 Video H264 Video amp Audio Video H264 Stream lame H264 Codec H264 Resolution D I Frame Interval 2 Bit Rate kbps 8000 VBR CBR O YBR CER Frame Rate 25 Figure 4 7 Video H264 Table 4 9 Video MJPEG Parameters Explanation Parameters Range Explanation Stream Name H264 To display the name of H264 stream which is shown in the Stream Profile in Figure 4 1 Live Video Settings Read only Codec H264 To display coding formate used Read only Resolution D1 4CIF 2CIF To set image resolution CIF VGA QVGA Note The stream will be cut off when the resolution is changed The client must be reconnected Frame Rate 2 60 To set frame interval Interval Bit Rate kbps 128 4000 To set the maximum bandwidth for video VBR CBR VBR or CBR To set control modes VBR means relaxed rate control that overall quality gives more importance CBR means stricter rate control to meet bitrate Frame Rate 1730 25 To set frame rate 3 Click Apply to enable the settings activated or click Restore to default to restore default settings End Video MJPEG Procedure 4 8 To Configure Video MJPEG Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page e American Dynamics 23 Web Configu
9. American Dynamics A Tyco International Company User Guide ADST E1 Single Channel Video Encoder Version 1 0 8200 0019 01 REVA Notice The information in this manual was current when published The manufacturer reserves the right to revise and improve its products All specifications are therefore subject to change without notice Copyright Under copyright laws the contents of this manual may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without prior written consent of Tyco International Ltd O 2010 and its Respective Companies All Rights Reserved American Dynamics 6600 Congress Avenue Boca Raton FL 33487 U S A Customer Service Thank you for using American Dynamics products We support our products through an extensive worldwide network of dealers The dealer through whom you originally purchased this product is your point of contact if you need service or support Our dealers are empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the Web at www americandynamics net Trademarks Windows is a registered trademark of Microsoft Corporation PS 2 is a registered trademark of International Business Machines Corporation The trademarks logos and service marks displayed on this document are registered in the United States or other countri
10. B or SD has been selected as storage disk in Storage Record subpage and the appropriate U disk or SD card has been inserted a snapshot can be made for the current video in the Live Video page Procedure 4 4 To Capture an Image Step Action Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page Select Live Video from the Web Main Page to pop up a configuration subpage of Live Video on the right as shown in Live Video Settings ADST E1 Single Channel Video Encoder Web Configuration 3 When the video to be captured occurs click the Snapshot button to save the current image in U disk or SD card It is saved in the adSnapshot Folder in root directory Note The image captured is the MJPEG stream The image size is the same as the MJPEG resolution set currently 4 If itis successfully saved a popup dialog box appears as shown in Figure 4 2 Snapshot Succeed Figure 4 2 Snapshot Succeed If snapshot fails for not connecting USB disk or SD card a popup dialog box appears as shown in Figure 4 3 Snapshot Error indicating there is a snapshot error Figure 4 3 Snapshot Error Stop amp Mute Right click in the live view video playing area select Stop to stop live view or select Mute to turn off the sound stop Mute Figure 4 4 Stop amp Mute Note Some changing operation will cause to refresh ActiveX Audio will be reimported after refreshing PTZ If PTZ control cable is connected and PTZ
11. Network PTZ Storage System Option Live Video Setting OSD Audio Video H264 Video MJPEG Privacy Mask External Input Trigger amp Action IP Address RTP amp RTSP Record Management Disk Management Status User Log Update Maintenance Date amp Time Description to configure image parameters switch stream profile and take snapshot to configure OSD parameters to configure audio parameters to configure parameters for video H264 to configure parameters for video MJPEG to configure privacy mask to configure parameters for external input and output to configure trigger and action to configure network parameters to configure RTP and RTSP port as well as multi cast parameters to configure PTZ control parameters to configure storage parameters to view disk usage format or eject disk to view status to configure username and password to view log to update device to maintain device to configure date and time ADST E1 Single Channel Video Encoder Web Configuration The Web page contains the following settings for configuration and management Live View Video Audio Alarm Network PTZ Storage and System This chapter describes how to configure ADST E1 with the built in Web configuration Before connecting to Ethernet or VideoEdge4 0 ADST E1 as a independent device can be configured with Web page Live View Live View can be used to configure image parameters of
12. action e Network to configure network parameters e PTZ control to configure PTZ control parameters Storage to configure and manage storage System to configure system parameters including user management e Language switch Login Logout The following options are supported for operator e Live Video to view live video adjust image parameters and operate PTZ e Video amp Audio to set video and audio parameters configure OSD and mask privacy e Alarm to configure alarm trigger and action e Network to configure network parameters e PTZ control to configure PTZ control parameters Storage to configure and manage storage System to configure system parameters excluding user management e Language switch e Log in out The following options are supported for viewer e Live Video to view Live Video adjust image parameters adjusting and operate PTZ Login amp Logout Login to the ADST E1 Web Page Procedure 3 2 Logging into the ADST E1 Web Configuration Page Step Action e FrTwme mm Lnarrucs 13 Pre Web Configuration Open IE browser in the client computer Type the IP address of the ADST E1 in the Address bar and Press Enter key to pop up the login page as shown in Figure 3 3 Login Page Chinese or Figure 3 4 Login Page English The default IP address for ADST E1 is 192 168 0 100 e American Dynamics 2010 FS ee a Figure 3 3 Login Page Chinese American Dynamics
13. as the followings for viewing Live Video normally Procedure 3 1 QuickTime Configuration Step Action 1 Open QuickTime Player e Amencan Dyarnics 11 Pre Web Configuration 2 Select Edit gt Preference gt QuickTime Preference to open QuickTime Preferences window as shown in Figure 3 1 QuickTime Preferences Figure 3 1QuickTime Preferences 3 Click Advanced tab and select Custom from the Transport Setup drop down list in the Streaming pane The Streaming Transport dialog pops up as shown in Figure 3 2 QuickTime Preferences Streaming Transport Regalar kudo Gromer update Goran Acteanced Transport eet Da FT ATA E En TEE re beca Encore Enable eee usn epa cy cede Tray doom fatal quia ior Pide E dry Figure 3 2 QuickTime Preferences Streaming Transport 4 Select UDP in the Transport Protocol drop down list and set PortlD as 554 12 ADST E1 Single Channel Video Encoder Pre Web Configuration 5 Click OK to close the Streaming Transport dialog box 6 Click Apply to put your settings into effect 7 Click OK to finish setting End Users Introduction Three levels of user access available are Administrator Operator and Viewer The following options are supported for administrator e Live Video to view live video adjust image parameters and operate PTZ e Video Audio to set video and audio parameters configure OSD and mask privacy e Alarm to configure alarm and its triggers and
14. aw a rectangle area to be masked by dragging the cursor d Click Mask Color frame to popup a color dialog box Select color for the new privacy mask e Click Save to save the settings 4 To edit an existed privacy mask a In live video select an existed privacy mask to be edited The property of the privacy mask appears on the right subpage b Change the name in Mask Name field c Change the color using Mask Color frame d Click Save to save the settings 5 To delete an existed privacy mask a In live video select an existed privacy mask to be edited b Click Delete to delete the privacy mask selected 6 Click Clear All Mask if all privacy masks are to be deleted Alarm Configuration Alarm menu is used to configure status for external input and output as well as triggers and actions External Input Configuration External Input configuration is used to set status for external alarm input and status as external alarm is triggered lt also can set delay time for external alarm input keeping effective Procedure 4 10 To Configure External Input ATETEA Lnarrucs 25 Web Configuration 26 Step Action Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page Select Alarm External Input from the Web Main Page to pop up a configuration subpage of External Input on the right as shown in Figure 4 10 External Input Close Close Close Close 300 Figure 4 10 External Input Select status neede
15. card as the storage disk for recording Enter the maximum record time in File Section Time second field Set value in Auto overwrite percentage field When the used space of the disk selected equals to this value the oldest video will be overwritten by the newest one ADST E1 Single Channel Video Encoder Web Configuration 7 From Record Enable radio box select Enable to begin recording and select Disable to stop recording The record is saved in the adH264Record file of the root directory 8 Click Apply to enable the settings activated or click Restore to default to restore default settings End Disk Management Only FAT32 is supported by ADST E1 Procedure 4 16 To Manage Disk Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page 2 Select Storage Disk from the Web Main Page to pop up a configuration subpage of Disk on the right as shown in Figure 4 17 Disk Management Total Sirec MB mona Price SqpracciMEB 3187 rea Dk LS Figure 4 17 Disk Management Table 4 12 Disk Management Parameters Parameter Button Explanation USB Total Size The total disk size of USB Free Space The free disk space of USB otatus The USB disk status SD Total Size The total disk size of SD card Free Space The free disk space of SD card otatus The SD card status Format To format U disk SD card Eject To safely remove U disk SD card by ejecting it Warning You must
16. control parameters are set in the PTZ menu you can realize PTZ control in Live Video page Refer to for control cable connections and refer to PTZ Control for PTZ control parameters configuration The following describe how to realize PTZ control in Live Video page Procedure 4 5 PTZ Control S ATETEA Lnarrucs 19 Web Configuration Step Action 1 Click on the live video to open the PTZ control interface as shown below Zoom Move Direction Close the PTZ Control interface Iris Focus Table 4 7 PTZ Functions Iris Open Auto iris Me I Close Zoom In Out Focus Near iit Far Pan Tilt Movement ms Pan Tilt Video amp Audio Video amp Audio menu is mainly used for configuring video audio coding parameters OSD and privacy mask OSD Configuration Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page 20 ADST E1 Single Channel Video Encoder Web Configuration 2 Select Video amp Audio OSD from the Web Main Page to pop up a configuration subpage of OSD on the right as shown in Figure 4 5 OSD Video amp AUGIO USD Enable Time Enable Disable Formats vYYY amm DD Enable Text 9 Enable Disable Text American Dynam Align Format Top a Figure 4 5 OSD 3 Select Enable of Enable Time radio box to display time and select time format needed from the Formates drop down list select Disable of Enable Time radio box to
17. d from the Alarm Input 1 drop down list The available options are Open and Close The default is Close Select status needed from the Alarm output 1 drop down list The available options are Open and Close The default is Close Select status needed from the Alarm Input 2 drop down list The available options are Open and Close The default is Close Select status needed from the Alarm output 2 drop down list The available options are Open and Close The default is Close In Input Debounce ms field enter time value during which the external alarm input remain effective Click Apply to enable the settings activated or click Restore to default to restore default settings End Trigger amp Action Configuration Trigger amp Action configuration is used to set conditions to trigger alarm the action after alarm is triggered and duration time for action keeping effective Procedure 4 11 To Configure Trigger amp Action Step Action Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page ADST E1 Single Channel Video Encoder Web Configuration 2 Select Alarm Trigger amp Action from the Web Main Page to pop up a configuration subpage of Action on the right as shown in Figure 4 11 Trigger amp Action Triggern Video loss Active External alarm output Active External alert utpu 2 Quiput Erecting Teese Figure 4 11 Trigger amp Action 3 Select a trigger condition from Trigger
18. e amp Time 3 Select a time zone from the Time Zone drop down list Refer to Table 4 13 Time Mode Parameters on page 39 select time synchronization mode and parameters Table 4 13 Time Mode Parameters Mode Parameter Explanation Synchronize with PC Date Time on ADST E1 is synchronized with PC Date amp Time synchronize Time and the current time for PC is displayed with PC Synchronize with NTP NTP server IP Time on ADST E1 is synchronized with server Address NTP server The NTP IP address and NTP Interval Seconds synchronizing interval should be set Set Manually Date To set date and time for ADST E1 Date amp Time manually Tine manually 5 Click Apply to enable the settings activated or click Restore to default to restore default settings S ATETEA Lnarrucs 39 Web Configuration 40 ADST E1 Single Channel Video Encoder Technical Specifications Table 5 1 Technical Specifications Category Specification Detalle Video Coding Standard H 264 MJPEG D1 4CIF 2CIF CIF VGA QVGA Frame Rate Flexible setting is allowed the maximum is 25 sec PAL Physical Operation 0 C 50 C Environment Storage 40 C 70 C Environment Humidity 0 95 120Lx98Wx42H mm mm Memory RAM 128MB Fflash 256 MB e Areca Anart 41 Technical Specifications Storage USB port 1 USB port SD slot 1 SD slot Table 5 2 Certification and Regulations Category Speicaon Deis mwv ENS 00000 08 owed USA FOOPaiiSdasA o
19. eee ew ae e He RR di Gere xp mary deas 32 Status Configuration LL 33 User Configuration e 3 attilio 33 LOO VOW resi a a Siani 34 Firmware Upgrade rs 35 MEE RE Ty 37 nn 0 IO 38 Technical Specifications 11 ADST El Single Channel Video Encoder Preface Thanks for purchasing our ADST E1 single channel video encoder Read this manual carefully before using the product and keep it well for future use How to Use this Manual 5 IV Finding More Information rias aperos TO LOTES V So ale cc NT T T Tm vi e American Dynamics Preface How to Use this Manual ADST E1 Single Channel Video Encoder User Guide mainly includes the product design installation configuration and technical specification This manual includes the following chapters Chapter 1 Introduction Provides description about product design LEDs and connectors Chapter 2 Installation Describes installation methods of ADST E1 Chapter 3 Pre Web Configuration Describes Preparation for Web configuration Chapter 4 Web Configuration Describes Web configuration of ADST E1 Chapter 5 Technical Specifications Describes technical specification of ADST E1 ADST E1 Single Channel Video Encoder Preface Finding More Information You can access ADST E1 manuals and online Help for more information about ADST E1 Manuals You can access manual by clicking FAQ from the Web menu bar e Ame
20. eject U disk SD before remove them 3 The Format button and Eject button appear in the Disk subpage if USB or SD is inserted Aer ican Lnarrucs 31 Web Configuration Format disk selected according to the following steps a Click Format to pop up a confirmation dialog box as shown in Figure 4 18 Format Confirm a Sem ima cmm own e a beg ip e Figure 4 18 Format Confirm b Click OK to format and a progress bar appears as shown in Figure 4 19 Format Progress Bar Figure 4 19 Format Progress Bar e Eject disk selected according to the following steps a Click Eject to eject the disk A confirmation dialog box as shown in Figure 4 20 Remove Disk appears and the recording action on the disk stops A Safe to Remove Hardware Figure 4 20 Remove Disk End system Configuration System menu is mainly used to configure user date amp time and device name view log and device status maintain and upgrade device 32 ADST E1 Single Channel Video Encoder Web Configuration Status Configuration Procedure 4 17 To Configure Status Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page 2 Select System Status from the Web Main Page to pop up a configuration subpage of Status on the right as shown in Figure 4 21 Status Device Name AST E d Finis de Ver sion Figure 4 21 Status Enter device name in the Device Name field as the only identif
21. es Any misuse of the trademarks is strictly prohibited and Tyco International Ltd will aggressively enforce its intellectual property rights to the fullest extent of the law including pursuit of criminal prosecution wherever necessary All trademarks not owned by Tyco International Ltd are the property of their respective owners and are used with permission or allowed under applicable laws Product offerings and specifications are subject to change without notice Actual products may vary from photos Not all products include all features Availability varies by region contact your sales representative License Information Mu use of us product is governed by certain terms and conditions Please see the detailed license information at the end of this manual ADST E1 Single Channel Video Encoder Table of Contents Preface How to Use this Manual eee RR eee eee ena IV Finding More Information 0 00 eee eee eas V CoventionS cosita do at Se ok A doh hw dio hn Boh ed Hea rn ee a ee e vi Introduction Overview cessa 1 FeatureS 6 44 60 64 deed ere a ER a a Ew ee ee ee 1 Connections cles 1 Compression Standard 2 Frame Rates 2 Hesolutions Li 2 Video Loss Detection Li 2 Bandwidth Throttling 0 2 Advanced Features 0 00 cee ee ee ee eee eee ee eee 2 Web Configuration 0 0 rn 2 BO CCUG US SI AAA 3 Front Panel i ee momo xmm m da R x Xcx R 3 C ROX OR 3o X 4c E mor
22. g c After upgrading a pop up window appears as shown in Figure 4 27 Updating indicating upgrading is completed and restart the device Figure 4 28 Upgrade Complete d Click Reboot to complete upgrading downgrading Note All configurations remain unchanged after upgrading 36 ADST E1 Single Channel Video Encoder Web Configuration Maintenance Procedure 4 21 System Maintenance Step Action Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page 2 Select System maintenance from the Web Main Page to pop up a configuration subpage of Maintenance on the right as shown in Figure 4 29 Maintenance Forest Lia thee LiB ion e Arado he factory seras necen f Figure 4 29 Maintenance 3 Heboot ADST E1 a Click Reboot to popup a confirmation dialog box as shown in Figure 4 30 Reboot confirm Figure 4 30 Reboot confirm b Click OK to begin reboot The indicating information appears as shown in Figure 4 31 indicating information em PMamiainarntce System is now rebooting Pease wait a fer minutes far your unt to la you m agan Click to try connecting to the Talk Figure 4 31 indicating information 4 Restore factory default including default IP address S American Dynamics 37 Web Configuration a Click Reset to popup a confirmation dialog box as shown in Figure 4 32 Reset confirmation f a Reset To factory wlacit Settingrt uH Figure 4 32 Reset confirma
23. he Web Main Page to pop up a configuration subpage of PTZ on the right as shown in Figure 4 15 PTZ Control Figure 4 15 PTZ Control 3 Select PTZ protocol from the PTZ Protocol drop down list The options available are AD422 Pelco P Pelco D Transparent and PizNull S American Dynamics 29 Web Configuration Select port mode from the Port Mode drop down list The options available are RS 485 2 lines and RS 422 4lines Enter baut rate in Baut Rate field The default is 9600 Enter the address used by PTZ in the Address field The default is O Click Apply to enable the settings activated or click Restore to default to restore default settings End Storage Configuration Storage menu is used for record and storage management Recording Management Procedure 4 15 To Configure Recording Parameters Step Action 1 2 30 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page Select Storage Record Management from the Web Main Page to pop up a configuration subpage of Record on the right as shown in Figure 4 16 Record Storage Record MJPEG Snapshot Storage Disk fuse sp H264 Storage Disk fuse sp File Section Time s 1200 Auto overwrite percentage E Record Enable Enable Disable Figure 4 16 Record From Snapshot Storage Disk radio box select USB or SD card as the storage disk for snapshot From H264 Storage Disk radio box select USB or SD
24. ication of the device Firmware version is automatically displayed in Firmware Version field Device Mac address is automatically displayed in Mac Address field Click Apply to enable the settings activated or click Restore to default to restore default settings oO oa A 0 User Configuration Username and password of all kinds of users can be changed with Security settings in ADST E1 Note Strongly recommend to change the password of Administrator Procedure 4 18 To Configure User Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page Amencon Dymarmics 33 Web Configuration 2 Select System User from the Web Main Page to pop up a configuration subpage of User on the right as shown in Figure 4 22 User Aimeri amor admin Pan il Oper sor operator Pra ti TT Figure 4 22 User 3 Enter the new password in the Password field below Enter the new password in the Password field below Enter the new password in the Password field below Note Administrator Operator and Viewer are read only 4 Click Apply to enable the settings activated or click Restore to default to restore default settings End Note Only Administrator can change the password Log View Procedure 4 19 To View Log Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page 34 ADST E1 Single Channel Video Encoder Web Configuration Select System Log fro
25. l composite video input interface e 1 RS485 RS422 connector for dome control e 1 RS232 port for debugging e 2 alarm in and 2 alarm out e 1 audio input e 1 audio output e 1 RJ45 network connector e 1 USB port e 1 SD slot e 1 resistor switch 75ohm e 1 power socket e Aerie Anart 1 Introduction Compression Standard ADST E1 supports standard video compression of H 264 and MJPEG Frame Rates ADST E1 supports a maximum of 25 PAL images per video channel The maximum frame rate for H264 and MJPEG can be set respectively in Web page Resolutions Table 1 1 Resolution LC NEL SNR 4CIF 704x576 pixels Video Loss Detection In the event of video loss an alarm is generated The alarm is automatically cleared when the video is restored Bandwidth Throttling The maximum bandwidth for H 264 is selectable between 128kbps 4000kbps Advanced Features e PTZ control with RS485 422 e The following protocols are supported e AD RS422 Pelco P Pelco D Web Configuration You can configue and view live video using ADST E1 Web page Refer to Web Configuration on page 17 for more information 2 ADST E1 Single Channel Video Encoder Introduction Product Design Front Panel American Dynamics PECL CLE O 0 Figure 1 1 Front view Table 1 2 Definitions of Connectors and LEDs on the front panel 1 RESET Reset button Supply power after power off and long press thi
26. m the Web Main Page to pop up a configuration subpage of Log on the right as shown in Figure 4 23 Log eee Figure 4 23 Log Click Next to view log on the next page click Previous to view log on the previous page enter page number in Page field and click Go to view log on the specified page Click Refresh to refresh the latest log Click Close to close Log window End Firmware Upgrade ADET E1 firmware can be upgraded or downgraded as required Procedure 4 20 To Upgrade Firmware 1 2 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page Select System Upgdate from the Web Main Page to pop up a configuration subpage of Upgrade on the right as shown in Figure 4 24 Upgrade Figure 4 24 Upgrade Click Browse button and use file browser to designate and select the Bin file to be used Click Apply to pop up a confirmation dialog box as shown in Figure 4 25 Upgrde confirm E E ELI Figure 4 25 Upgrde confirm Click OK to start upgrade It is not allowed to configure ADST E1 and view video during upgrading The upgrading process is as follows S American Dynamics 35 Web Configuration a File uploading starts and a progress bar appears as shown in Figure 4 26 File Uploading Figure 4 26 File Uploading b Updating starts when file uploading finishes and a progress bar appear as shown in Figure 4 27 Updating p L Em gc m F Figure 4 27 Updatin
27. r a easier identification e Method B Post configuration of ADST E1 Post configuration of the ADST E1 video encoder occurs after physical installation to the network This method is suited to smaller network or where only one ADST E1 video encoder is being added and configured at one time e Areca Anart 7 Installation Installation Method A Pre configuration Remove the ADST E1 from the packaging For PoE model For PS Model Connect a PoE injector splitter or POE switch to the ADST E1 Ethernet port Connect a laptop to the Ethernet port of the ADST E1 encoder using a cross over cable Connect a laptop or PC Connect power to the to the PoE injector splitter ADST E1 encoder using a cross over cable Connect power to the PoE injector splitter Open a browser window and enter the IP address of the ADST E1 192 168 0 100 Refer to chapter 4 Web Configuration and configure the following settings on the ADST E1 encoder Real time PTZ control only Dome Video Audio Storage SensorNet if applicable System Alarm Refer to the Quick Start Guide to connect the ADST E1 to the network and then connect the analog video source PTZ control cable if dome U disk or SD card Alarm In Out and power cables if PoE not supported Refer to the America Dynamics Video Edge Server Installation and User Manual for adding an ADST E1 encoder ADST E1 Single Channel Video Encoder Installation Installation Method B
28. ration 2 Select Video amp Audio Audio from the Web Main Page to pop up a configuration subpage of Video MJPEG on the right as shown in Figure 4 8 Video MJPEG IO O O Oy PER D Dan Video amp Audio Video MJPEG Stream Hame JPEG Codec MJPEG Resolution DI Frame Rate 75 Quality Better Figure 4 8 Video MJPEG Table 4 10 Video MJPEG Parameters Explanation Parameters Range Explanation Stream Name MJPEG To display the name of MJPEG stream which is shown in the Stream Profile in Figure 4 1 Live Video Settings Read only Codec MJPEG To display codec used Read only Resolution D1 4CIF 2CIF To set image resolution CIF VGA QVGA Frame Rate 1 25 To set frame rate Quality Best Better or To set image quality Good 3 Click Apply to enable the settings activated or click Restore to default to restore default settings Privacy Mask Procedure 4 9 To Configure Privacy Mask Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page 24 ADST E1 Single Channel Video Encoder Web Configuration 2 Select Video amp Audio Privacy Mask from the Web Main Page to pop up a sub configuration subpage of Privacy Mask on the right as shown in Figure 4 9 Privacy Mask Figure 4 9 Privacy Mask 3 To create a new privacy mask Click New with default setting of the new privacy mask appears below b Enter a name for the new privacy mask in Mask Name field c In live video dr
29. rican Dynamics Preface Coventions This guide uses the following text formats and symbols Bold This font indicates screen elements and also indicates when you should take a direct action in a procedure A command or character to type A button or option on the screen to press or A key on your keyboard to press A screen element or name Multilevel menu is separated by f For example Video amp Audio Video H264 indicates the submenu Video H264 of the Video amp Audio menu The following items are used to indicate important information Note Indicates necessary complementary description for performing a task vi ADST E1 Single Channel Video Encoder Introduction Overview ADST E1 single channel video encoder hereafter referred to as Video Encoder which is based on TI latest platform offers dual streaming of H 264 and MJPEG It supports real time coding for multiple resolutions and data transmission of unicast multi cast streaming and also offers USB interface and SD SDHC card slot for local storage The video encoder is available in two ways Power over Ethernet POE and e Power supply PS ADST E1 converts video from analog cameras and domes into a network compatible IP signal It can be integrated into VideoEdge NVR 4 0 and also can be viewed managed and monitored by Tyco Victor unified video management system Features Connections ADST E1 has the following physical connections e 1 channe
30. s button till the STAT LED flashes slowly about 15 seconds When slow flashes become normal flashes the factory default is restored including IP address RS232 RS232 port used for debugging 3 USB port Connects to USB devices such as U disk Portable hard disk is not supported now SD slot Connects to SD card PWR LED On Power on Off Power off NET LED On Network is connected Flashing traffic on the network Off Network is disconnected 7 STAT LED Normal flashing 2 5times sec normal operation Slowly flashing 1time sec occurs when press long the Reset button Rapidly flashing firmware updating Often bright system starting Off Device error S ATETEA Dynamics 3 Introduction Rear Panel 5 VIDEO IN AUDID DUT AUDIO IN En ny NETWORK POWER Figure 1 2 Rear View Table 1 3 Definition of Connectors on Rear Panel HE AUDIO OUT Audio output port 3 5mm 2 AUDIO IN Audio input port 3 5mm 3 VIDEOIN Composite video input PAL BNC port Termination resistor Open Close swich 750hm 5 I O Provides RS485 422 interface SensorNet interface 2 ALARM IN and 2 ALARM OUT Refer to Connector Pin Definitions on page 4 for more information ei NETWORK 10 100 BaseT auto adaptive PoE optional POWER Power supply 12V DC Connector Pin Definitions Table 1 4 I O Connectors amp Pins Definitions IN1 ALARM IN1 Tx RS 4221 A RS 485 A IN2 ALARM IN2 Tx RS 4222 B RS 485 B COM ALARM IN COM Rx
31. s drop down list The available options are Video Loss Disk Full Disk Error External Alarm Input 1 and External Alarm Input 2 From When Triggered check box select action s occur s when alarm is triggered In Output Effecting time s field input time of duration for action triggered 6 Click Apply to enable the settings activated or click Restore to default to restore default settings End Network Settings Network menu is used to set IP address and RTP amp RTSP parameters IP Address Configuration The following configurations are available in IP Address configuration subpage e DHCP e IP Address e Subnet Mask e Gateway Procedure 4 12 To Configure IP Address Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page FrTwme mm Lnarrucs 27 Web Configuration 2 Select Network IP Address from the Web Main Page to pop up a sub configuration page of IP Address on the right of the screen as shown in Figure 4 12 IP Address A ework IP Address Figure 4 12 IP Address 3 If Enable of the DHCP radio box is selected IP address will be obtained from DHCP server The fields below will gray out and nothing needs configuring Go to Step 8 If Disable of the DHCP radio box is selected a pop up window appears as shown below Click OK to confirm NC um Figure 4 13 Disable DHCP Confirm Enter the IP Address in the format xxX XXX XXX XXX Enter the IP Mask in the format xXX
32. the live video and also to view the video standard of the camera connected Configuring Image Parameters Procedure 4 3 Configure Image Parameters Step Action 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page e Amentcan Linares 17 Web Configuration Select Live Video from the Web Main Page to pop up a configuration subpage of Live Video on the right as shown in Live Video Settings Configure video parameters in this page which will take effect right away SreumProtie HL i piinsaa 1 4 ii P i Conrad 1 125 HM i Satur acier 17120 m ii Figure 4 1Live Video Settings Video Standard field shows the video standard of the camera connected currently Select a stream profile from StreamProfile drop down list Two profiles are available H 264 and MJPEG Specific parameters for Profile can be set in Video amp Audio Video H 264 and Video amp Audio Video MJPEG Image setting parameters Brightness drag the slide to adjust the brightness or enter value directly in the right Value pane Value range is 1 128 Contrast drag the slide to adjust the contrast or enter value directly in the right Value pane Value range is 1 128 Saturation drag the slide to adjust the saturation or enter value directly in the right Value pane Value range is 1 128 Click Reset to Default button to restore default settings End Snapshot If US
33. tion b Click OK The indicating information appears as shown in Figure 4 33 Information EL EID ER Mammie E n Sy tem is now rebooting AIL BE ERI D LE d init to log veu m again eonnecnnmg b 1s HE Figure 4 33 Information 5 Restore factory default excluding IP address a Click Restore to default to Popup a confirmation dialog box as shown in Figure 4 34 Restore Confirmation e Reset To Defauhts Keep IP address Figure 4 34 Restore Confirmation b Click OK The indication information appears as shown in Figure 4 35 Information Trete m 7 SARAS System ls now rebooting Pia wit a f minutos fica a ni F i go your unit to lag you in again P Sii Lick Lo try Ono To The Figure 4 35 Information Date amp Time Procedure 4 22 To Set Date amp Time Step Action 38 ADST E1 Single Channel Video Encoder Web Configuration 1 Login to the ADST E1 For more details refer to Login to the ADST E1 Web Page 2 Select System Date amp Time from the Web Main Page to pop up a configuration subpage of Date amp Time on the right as shown in Figure 4 36 Date amp Time System Dat ER Time Time Zone GMT 48 00 Beging Perth Su Time Made 2 yncii onse wit PC Date Time eychronize with PC Culo Tino Syrichir onze with HIP server MTP ermer IP address Inb rcaWeconday Set nanikally Date E tim manualit Cain no mmo Time HH MM X Figure 4 36 Dat
Download Pdf Manuals
Related Search
Related Contents
Warehouse of Tiffany T14288TGRA Instructions / Assembly TLA 510 & 520 System Unit - Artisan Technology Group BMC Performance Manager for Hardware Series 6000 5.0M Italian manual de bancos - bkcr.net,software para punto de venta colombia Nous, Animateurs ? Même pas peur Ortsrechtssammlung - Glessen Instrucciones de servicio Lire l`article complet Architecture de la Liquid Saffire 56 Copyright © All rights reserved.