1. FEE RANSON A USER MANUAL DC100G UNI RAM CORPORATION ONTARIO CANADA Revision 2010 06 MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 CONTENTS INTRODUC TON RR lc ties 3 CAUTIONS AND li ic sheen lioatc cal 3 FEATURES AND gt 4 SAFETY FEATURES eae nc E 4 SOLVENT REQUIREMENTS AND DEFINITIONS 4 DELIVERY INSPEC REEE a aAa 5 5 SET UP AND CONNECTIONS 6 OPERATING 9 10 OPERATION STATUS MESSAGES 11 ERROR MESSAGES TROUBLESHOOTING 12 14 gmon e aE EEA EEEE E EE 15 THEORY OF OP EA 16 0 17 MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 INTRODUCTION Uni ram holds many patents on designs used in its innovative products Every machine is tested for com pliance with Quality Assurance standards Follow the instructions on preparation use and operation to operate this machine safely and effectively Ensure that this manual is readily available to the operator at all times If you have any questions about the operation of this machine contact North America Uni ram Technical Service 1 800 417 9133 Other Contin
2. CONTROL PANEL SERVICE PANEL KEYPAD CLEAN SOLVENT CONTAINER CLEAN WATER CONTAINER TANK LID FLOAT DRUM MIXER IN WATER WASTE INK SEPARATOR CONTAINER INSIDE DIRTY SOLVENT CONTAINER MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 3 AIR CONNECTION This unit is equipped with air operated Dual Diaphragm pumps and requires a supply of clean dry air of at least 85 PSI 6 kg cm2 and 2 CFM Note If necessary install a Moisture Filter Apply teflon tape to the Air Inlet Fitting 1 4 NPT Female Threads and connect the Moisture Filter to it if necessary Connect the air supply to the Filter Connect the air supply directly if a Filter is not used Make sure that there are no leakages at the connections Also make sure that the air is free of dust rust and other contaminants Drain the Moisture Filter before each recycling 4 LEVEL SENSOR TUBES ONE RED ONE CLEAR SOLVENT WATER HOSES 3 BLACK DRUM MIXER AIR LINE ORANGE Using the picture and table on the next page as a guide connect the various tubes and hoses to the cor rect connectors at the back of the solvent recycler CONNECTION MAG RAM A2 11 L2 A3 El A5 A7 E2 Al F1 F2 A4 E3 A6 F3 CAUTION BOTH GROUNDING WIRES GR MUST BE ATTACHED AS SHOWN Air Supply Line with Moisture Filter Filter is optional Air Line for Drum Mixer Orange Tube Not Used Not Used Dirty Solvent Water Mixture IN Not Used from dirty drum Pre
3. 06 MAINTENANCE CAUTION Wear protective clothing according to local regulations A minimum of solvent resistant gloves googles and mask are recommended CHECKING AND INCREASING LID TENSION BY ADJUSTING THE SPRING BOLT Some decrease in tension or lid tightness is normal with average use This procedurre should only be done if the Lid is leaking solvent or there is excessive looseness Before following this procedure check for a worn Lid Gasket or loose Hinge Bolts Replace the Lid Gas ket or tighten the Hinge Bolts as needed If the Lid appears to be sealing tightly but is leaking solvent the poblem may be a blockage in the solvent flow path or a set point that is too high for the solvent being recycled Call for service If the Lid is not leaking solvent but still appears to be too loose follow this pro cedure to increase the Lid tension ae Bolt Head This procedure tightens the Lid by increasing the tension on the spring attached to the Lid Bar Spring Bolt Assembly The Lid and Bolt Assem bly is carefully designed as a Safety Pressure Relief system to prevent a dangerous build up of pressure inside the closed tank Do not adjust Spring Holding Nut the Spring Holding Nut by more than 2 full turns maximum If 2 full turns do not solve the problem call for service e While holding the Bolt Head with a wrench turn the Spring Holding Nut no more thana 1 2 turn at a time Turn in a counter clock wise direction as you look
4. FLOAT AFTER EACH BATCH To ensure maximum performance it is extremely important to clean and maintain the Distillation Tank Lid and Float system as follows Wear protective clothing according to local regulations A minimum of solvent resistant gloves googles and mask are recommended sure the unit is in READY mode e Open Safety Cover fully e Unlatch and open the Tank Lid Use EXTREME CAUTION to avoid damage to the Float System Using a cloth soaked in clean solvent wipe the Tank Lid interior and the exposed part of the Lid Gas ket e While supporting the Float System firmly with one hand clean the float ball and stem with the other When finished check that the float moves freely and that all hardware is tight If neccesary re tighten any loose hardware e help in the cleaning of the Tank interior add solvent to the Tank automatically by activating the CLEANING MODE cycle push and hold O K button then press STOP The DISPLAY will read CLEANING MODE e Press START to continue or STOP to cancel If you continue the drain is closed and the filling pump runs for about 10 seconds to add some solvent to the tank This is followed by heating if necessary The DISPLAY will then read READY TO CLEAN for 5 seconds followed by PUSH TO DRAIN Do not press O K yet Proceed with the cleaning Using a cloth soaked in clean solvent wipe the Tank walls and botto
5. down on it e After each 1 2 turn operate the unit normally Spring Bolt Assembly and check for leaks REPOSITIONING LID and TIGHTENING HINGE BOLTS The Hinge bolts can loosen over time causing the lid to shift off center This can lead to an inadequate seal and leaking around the Gasket Loosen the bolts reposition the lid and re tighten the bolts Hinge Spring Bolt Assembly Cross Bar 14 MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 MAINTENANCE REPLACING LID GASKET Remove the old gasket by prying it out gently with a screw driver Place the new gasket in the groove and press in firmly all around REPLACEMENT PARTS DESCRIPTION SAFETY COVER DIAPHRAGM PUMP 2 DIAPHRAGM PUMP 4 LID GASKET VITON DOOR HANDLE amp 2 SCREWS 15 MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 THEORY OF OPERATION DISTILLATION PROCESS Waste solvent consists of the original solvent plus liquid and solid materials picked up during use of the solvent Recycling separates the original solvent from the waste materials During the recycling process the distillation tank fills with dirty solvent and the heating element heats the mixture The solvent mixture boils and the vapour passes through a cooling condenser where purified clean solvent ready for use condenses out Waste materials in the dirty solvent boil at a temperature substantially above the Tem perature Set Point so they
6. expressed or implied by statute or otherwise To make a claim call Uni ram Service at 1 800 417 9133 and quote the serial number of the unit SERIAL NUMBER PURCHASE DATE PURCHASED FROM 17
7. remain in the distillation tank for disposal Solvent Recycling Vapour Outlet tube vapor moves to cooling condenser from distillation tank Distillation Tank Condenser cools vapor ae Heating Element to a liquid Receiving Pail contains clean recycled solvent Distillation Cycle Heating starts temperatue rises Vapourization starts Vapourization ends AUTO SHUT OFF BAKE TIME starts see SETUP Baking finishes cooling begins Cooling is complete Separation occurs Temp SET POINT 777777777777 TEMP TIME 5 lt 16 MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 Full Product Warranty These Uni ram products have been engineered and manufactured to high performance standards Each unit has been subjected to detailed factory testing before shipment This product comes with a one year full warranty from the date of purchase Uni ram Corporation re serves the right to repair or replace the unit free of charge to the original purchaser if a part is found to be defective in material or workmanship as determined by factory service personnel The items listed below under Conditions of Warranty as consumables are not covered Uni ram reserves the right to direct the customer to ship the unit collect to the Uni ram factory or to an ap proved Service Center for repair using the Uni ram Return Goods Procedure or to repair the unit o
8. restored WATER SEPARATOR TANK SOLVENT WATER MIXTURE INLET 1 SOLVENT OUT PUMP 2 WATER OUT PUMP 3 AIRLINE BLUE 4 LEVEL SENSOR 1 5 LEVEL SENSOR 2 6 7 MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 OPERATING PARAMETERS The computer is pre set at the factory and the initial setup of the unit is usually done by a Uni ram certi fied technician If the inititial solvent mixture is changed or the initial settings need to be fine tuned chang es can be made by the operator in SETUP mode described below For advice on changing the settings or to correct a problem during the operation of the unit call for service section INTRODUCTION SETUP MODE We recommend that only personnel with expert understanding of the unit adjust the settings Adjust set tings only when the display reads READY S P xxx C To start SETUP press and hold SETUP key and press START Use or key to adjust setting To move to the next parameter press OK STEP DISPLAY KEY TO KEY TO DESCRIPTION ADJUST ACCEPT LOW AIR PRESSURE Appears if Air supply is not yet connected READY S P 200 C Indicates unit is ready and set to 200 C SET UP MODE Indicates SETUP mode is active CYCLES 1 Change to 2 see Example Scenario SET PT 200 C Depends on BP of waste mixture LO TEMP PWR 100 Adjust together to compensate for exces HI TEMP PWR 80 sively vigourous vapourization which can S
9. standard 55 US Gal drum is used However if a smaller container is used the position will have to be adjusted as described 7 DRUM MIXER e Insert the shaft into the motor section and tighten the Allen screws well e Remove the bung from the larger opening of the Dirty Solvent Container Insert the impellor and shaft into the drum and screw the motor into the opening making sure it is tight Caution the motor must be tightly installed so that the shaft is held in a vertical postion away from the wall of the Drum Connect the Drum Mixer Air Line orange to the mixer Use an air line lubricator not supplied The speed of the mixer may be adjusted by adjusting the air flow using the Ball Valve included The on off and duration of mixing is controlled by the computer Notes 1 This Drum Mixer can only be used with a standard 55 US Gal Drum 2 To prolong the life of the mixer motor an air line lubricator not supplied is recommended It must be installed only on the Drum Mixer Air Line orange To prevent serious damage to the machine DO NOT use an air line lubricator on the main air line 8 RECEIVING TANK WATER SEPARATOR PRIMING and CONNECTIONS initial setup to prime the separator add two litres of tap water through the opening in the left side of the tank No 2 below The connections shown below are made at the factory Use the following information if the connections are removed and need to be
10. ARATOR FLOAT One of Level Sensor Automatically stop pro YELLOW FLASHING Floats of Water Separa cess Check Level sen tor is stuck at full posi sors and transfer pumps tion Not closed in 90 for defect Press START seconds to resume process from where stopped CHK HEAT CIRCUIT Operation and Self YELLOW STEADY test message There is opening in Heater circuit LOW AIR PRESSURE _ Before and during air Automatically stop pro YELLOW FLASHING solenoid operation cess Pressure recovery will re start from where it stopped LOW WASTE LEVEL Filling time out in Initial Process is terminated YELLOW STEADY Filling Both Boiler Replenish waste source Level Sensor 1 and 2 and press START did not open button operation will resume from where it stopped REFILL TIME OUT Float Switch did not The process will be YELLOW STEADY open within pre set refill competed and this ing time display will show at the end Pressing STOP button will return to READY mode 12 MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 ERROR MESSAGES AND TROUBLE SHOOTING continued MESSAGE DESCRIPTION REMARKS LIGHTS BUZZER BOILING TIME OUT LO VOLTAGE RESET RESET OCCURRED WAIT FOR READY OUTPUT DRUM FULL DEBRIS PAIL FULL WATCH DOG RESET ILLEGAL OPCODE ILLEGAL ADDRESS No vapor within factory pre set time Low Voltage power supply happened during process Power supply irregular
11. DIRTY CLEAN SOLVENT IN SOLVENT OUT DRUM MIXER LOCATION This unit is certified for use in non hazardous and hazardous locations Class 1 Division 1 Group D and Class 1 Division 2 Group D e Non hazardous Locations If using a plug rated for non hazardous locations the unit must be located outside of a hazardous lo cation In such a location we recommend that the receptacle be located a minimum of 6 feet from the unit and a minimum of 3 feet from the floor We also recommend that the unit be located at least 6 feet from electrical receptacles switches pilot lights fixtures etc To clarify the definition of an appropri ate location contact your local authority This unit must be connected to the power supply only by a qualified electrician in accordance with an appropriate Electrical Code e Hazardous Location In hazardous locations Class 1 Division 1 Group D and Class 1 Division 2 Group D the power cord must be connected to the main power supply only by a qualified electrician in accordance with the National Electrical Code This equipment must be properly connected to an explosion proof outlet receptacle or hard wired Select a Location That Meets EACH AND EVERY Requirement Described Below 1 Comply with the instructions in the section CAUTIONS AND WARNINGS 2 Make sure that the unit is placed in a in a location so that there is plenty of space to manoeuver the drums especially when they are full There must al
12. The auto ignition temperature of the solvent to be distilled must be higher than 250 C 482 F for safe operation Do not recycle Nitrocellulose The auto ignition temperature is 135 C 275 F e For good water separation to occur the organic oil based component of the solvent mixture must be non miscible in water and have a specific gravity of 0 85 or less DEFINITIONS Flash Point The lowest temperature at which the vapor of a solvent can be made to ignite momentarily in air Auto ignition temperature often referred to as ignition temperature or ignition point the temperature at which solvent ignites by itself MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 DELIVERY INSPECTION e Inspect the shipping carton for any sign of transport damage Carefully remove the unit from the ship ping carton and check the unit for damage Report any transport damage immediately to the carrier and your vendor Initiate a freight claim with the carrier The manufacturer is not responsible for freight damage e Check for the parts listed and or shown below If any parts are missing contact your supplier Addi tional consumables and accessories are also listed Level the unit using the adjustable feet and install the Door Handle included in the ACCESSORY CONNECTION HOSE KITS ACCESSORY KIT CONTENTS Door Handle amp 2 Screws Connection Hose Kits see photo on right Lid Gasket WATER OUT
13. WITCH TEMP 2002 cause leakage at the Lid Gasket 9 MIXING 5M The Drum Mixer mixes the waste mixture Refill Time duration of Refill Cycle 10 REF TIME 1HOOM OR OK Range 1 24 hours best setting is max without loss of ouput Minimize to allow more Refill Time best setting determined by Drain Temp the na POST HEAT OR OK ture of the waste content and the DOWN SLOPE setting set at the factoy or dur ing initial setup Increase to lower the viscosity of the DRAIN TEMP 100 C LOR OK waste or to allow a shorter Post Heat setting to reduce the Cool Down time decrease if too much odour READY S P 200 C Indicates unit is ready and set to 200 C MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 OPERATION A Atypical setting is where CYCLES 2 cycles each cycle is 12 15 hours each The operation con sists of the following 1 Press START The unit will operate continuously for 24 30 hours and drain the drum of dirty solvent producing clean solvent and distilled water 2 CHECK CONTAINERS HOLDING DIRTY SOLVENT CLEAN SOLVENT AND CLEAN WATER At the end of the batch remove the dirty drunm clean solvent drum and clean water drum as neces sary Prepare drums for the next batch 3 DISPOSE of WASTE INK Clean the tank lid and float and dispose of the waste ink residue in the regular waste ink drum 4 CLEANING AND CHECKING THE DISTILLATION TANK LID AND
14. ase may continue for a while without displaying if the distillation process has been manually set to a longer time COOLING will begin when POST HEAT is finished MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 ERROR MESSAGES AND TROUBLE SHOOTING If an abnormal condition is detected by the unit s Self diagnostic System the Display Panel shows one of the following error messages To get help in correcting the problem note the massage and call for service MESSAGE DESCRIPTION lt lt LIGHTS 8802288 DISCONNECT POWER Temperature at TC 1 Defective Heater TRIAC RED FLASH amp BUZZER continues to rise by is the most likely cause more than 30 C within Power supply must be 10 minutes after Heater disconnected as soon is turned off as possible COND THERMOSTAT Condenser Thermostat Unit will not start YELLOW STEADY is open during initial when START button is fault monitoring cycle pressed until the con denser cools down CONDSR OVER HEAT Condenser Thermostat Automatically stop RED STEADY is open up to 10 min heater CHECK FAN After 10 min Automatically stop pro RED STEADY cess except Fan CHK TANK SENSOR TC 1 has broken con Automatically stop RED STEADY nection process CHK COND SENSOR TC 2 has broken con Automatically stop RED STEADY nection process CHK BOILER FLOAT If Float shows FULL Automatically stop YELLOW FLASHING after draining Debris process SEP
15. ents Contact Your Supplier CAUTIONS AND WARNINGS The operator should wear protective clothing in accordance with local safety and environmental regulations with a minimum of face goggles and gloves along with an apron and respirator if required e Always disconnect the power source before performing maintenance DO NOT SMOKE OR USE THIS EQUIPMENT NEAR A POTENTIAL SOURCE OF IGNITION SUCH AS SPARKS OR AN OPEN FLAME This unit must be located at least 6 feet 1 8 m from all potential sources of ignition including electrical receptacles switches pilot lights fixtures and contacts when installed in a non hazardous locations The ambient temperature must be between 5 C 41 F to 35 C 95 F e NOT RECYCLE NITROCELLULOSE WHICH IS EXTREMELY VOLATILE IT AUTOMATICALLY IGNITES 135 C TO 166 275 F TO 330 F Do not install operate or maintain this equipment where the auto ignition temperature of the solvent is lower than 250 C 482 F Do not install operate or maintain this equipment where the auto ignition temperature of hazard ous atmosphere s is lower than 250 C 482 F Solvents that are recycled can be flammable Establish and follow safe practices to store and handle solvents e Units must be installed by a qualified electrician e Install on a dedicated circuit with sufficient current capacity see specifications section MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Re
16. ity happened during process This message is dis played for 5 seconds when START button is pressed before READY mode Water Drum or Solvent Drum Level Sensor NC Micro Switch detects FULL level Debris weight sensor NC Micro Switch de tects FULL weight Software integrity has been temporarily halted Software malfunction happened and has been temporarily halted Software malfunction happened and has been temporarily halted Automatically stop process Automatically stop process Press START and it will resume from where it stopped The process was automatically stopped Press START and it will resume from where it was stopped After 5 seconds display will return to COOLING T XXXC Automatically stop pro cess Replace the clean pail and press START It will resume from where it stopped Automatically stop pro cess Empty the debris pail and press START It will resume from where it stopped Automatically stop pro cess Press START It will resume from where it stopped Automatically stop pro cess Press START It will resume from where it stopped Automatically stop pro cess Press START It will resume from where it stopped 13 YELLOW STEADY YELLOW STEADY YELLOW STEADY YELLOW FLASHING YELLOW FLASHING YELLOW FLASHING YELLOW FLASHING YELLOW FLASHING MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010
17. m If the residue is baked scrape it off carefully so as to avoid damaging the Tank When finished press the O K button to drain the tank e When the Tank is fully drained wipe the walls clean with a clean cloth e IMPORTANT Proper sealing of the Tank Lid is essential for both efficiency and safety Check that the Lid Gasket is properly seated in the groove and that it is clean Replace if damaged or worn see Maintenance section Also make sure that the Tank sealing surface is clean and free of debris e Close the Tank Lid latch it and lock it down e Check the Lid Tension sealing tightness If the Lid appears to be loose any way or leaking sol vent read and follow the instructions given in the Maintenance Section of this Manual e Close the Safety Cover and check that the Locking Mechanism is working properly Notes During the first cycle check all connections for leaks and watch for any Error Messages See the section Error Messages and Troubleshooting for more information on each Error Message 10 MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 OPERATIONAL STATUS MESSAGES The following messages are displayed during normal operation COOLING Alternate during COOLING DRAIN VALVE OPEN Displays for about 5 sec FINAL TRANSFER Displays during TRANSFER READY S P 200 C Indicates unit is ready and set to 200 C REFILL occurs first followed by POST HEAT Note the POST HEAT ph
18. n site To prevent damage in transport the purchaser must ship the unit in the original packaging or use alter nate adequate packaging All units must be shipped clean and free of solvent Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the purchaser stores handles or uses the product Uni ram makes no warranty or claim either expressed or implied with respect to this product s fitness for any purpose or the result to be obtained from its use This condition applies to the sale of all products and no representative or distributor of Uni ram Corporation has the authority to waive or change these conditions This warranty applies only to the original purchaser and does not apply if the unit has been misused overloaded neglected altered or used for any purpose other than those specified in the operating and installation instructions Deterioration due to normal wear is not covered by this warranty Damage due to accident transportation fire floods or acts of God is also not covered Units whose serial numbers have been altered or removed are not covered The warranty is invalid if unauthorized abrasives are used in this unit Unauthorized attempts at self repair or alterations by the owner also invalidate this warranty Interior or exterior finishes are not covered by this warranty Consumable Items are not covered by this warranty This warranty replaces all other warranties
19. so be enough space behind the unit to accomo date al the hoses connections and required ventilation Ensure that the safety lid and door opens fully The unit must be in a location where people or equipment cannot disturb the cables or connections The cord must be connected directly to the main power supply an extension cord cannot be used MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 SETUP AND CONNECTIONS PLACEMENT OF CONTAINERS POWER CONNECTION AIR CONNECTION LEVEL SENSOR TUBES SOLVENT WATER HOSES DRUM MIXER AIR LINE GROUNDING WIRES CONTAINER CONNECTIONS and ADJUSTNG THE LEVEL SENSOR TUBES DRUM MIXER RECEIVING TANK WATER SEPARATOR PRIMING and CONNECTIONS ON 5 3 1 PLACEMENT OF CONTAINERS Arrange the three containers shown in the following diagram in a convenient way that does not block the free flow of air around the unit Note the full containers will be very heavy Make sure there is enough space to manoeuver them in a safe manner 2 POWER CONNECTION Connect the unit to a dedicated 20A 200 240V branch circuit using one of the methods described in the Location section Note operating the unit at a lower voltage eg 208V may result in reduced per formance On first power up and when the unit is ready to begin a new cycle the Display Panel shows READY S P XXX C SP Set Point XXX is the set point temperature SAFETY LID GASKET COVER
20. ssurizes the Distillation Tank during waste draining to improve the flow of excep tionally viscous thick material The default is OFF Turn ON only when necessary MANUAL SOLVENT RECYCLER PRINTING INDUSTRY DC100G Revision 2010 06 5 GROUNDING WIRES To prevent the build up of static electricity any container containing solvent must be grounded The hose for the dirty solvent and the clean solvent comes with green grounding wire Connect one end to the grounding screw on the back of the unit and the other to either the rim of the solvent container if it is metal or to the metal pickup rod if the container is plastic use the alligator clamp provided on the con tainer end of the wire to connect to the pick up tube 6 CONTAINER CONNECTIONS and ADJUSTNG THE LEVEL SENSOR TUBES The three Connection Kits each have a long metal rod at the container end This rod is to be placed in the appropriate drum or container so that it sits on the bottom See the diagram Connection Diagram The CLEAN WATER and CLEAN SOLVENT rods also have a shorter metal tube attached to the long rod This shorter metal tube and the attached plastic tube either red or clear are part of the level sensing system To work correctly and prevent overflow the position of the shorter metal tube must be adjusted up or down using the set screw so that the bottom opening is about 6 inches below the top of the drum or container This tube should not require adjustment if a
21. vision 2010 06 FEATURES AND SPECIFICATIONS All Uni ram Solvent Recyclers feature rapid start direct electric heating of solvent and a short cool down time due to high efficiency condensers and air cooling with a motor driven fan SAFETY FEATURES e This unit is certified under UL standard 2208 and CSA standards C22 2 No 30 and No 88 for use in non hazardous locations as well as for use in hazardous locations Class 1 Division 1 Group D T2A and Class 1 Division 2 Group D T2A Explosion proof construction and intrinsically safe electric circuitry Computer controlled with many built in safety programs including temperature control of all critical points including tank condenser and fan motor Self Diagnostic error messages are displayed on the Display Panel e Dual lid cover system Warranty 1 year on unit 2 years on pump Note on voltage SPECIFICATIONS DC100G Operating the unit at a lower voltage eg 208V may result in reduced perfor VOLTAGE mance RECOMMENDED CIRCUIT AMPS SOLVENT REQUIREMENTS Dirty solvent to be distilled must meet each requirement described below Be sure to read the MSDS Material Solvent Data Sheet on the properties of the pure solvent to be recyled The BP Boiling Point of the dirty solvent must be less than 240 C 464 F BP increases with greater contamination Note Recycle recently contaminated solvent only Standing solvent can become acidic over time