Home

SIENNA product catalog

image

Contents

1. SIENNA SYSTEM Switch to the future Home control ingeniously simple Energy efficiency SIENNA9 SYSTEM Switch ta the utes SIENNAS SYSTEM the new dimension in home automation Ingeniously simple Easy to install and easy to reconfigure Installation and configuration can be done with a screwdriver No need for a PC or special software Can be combined with all commercially available switches and power outlets Can be retrofitted in all existing buildings Simplifies wiring and eliminates detailed wiring plans No additional cables or electromagnetic smog Extremely reliable due to usage of LON technology Simply ingenious The SIENNA elements form a bus system consisting of sensors and actuators which use the in house power lines as a communication bus The SIENNA system revolutionizes wiring plans and places the intelligence of the system into smart elements located wherever they are needed in a home or a building The extremely simple installation process makes SIENNA the ideal system not only for new buildings but also for reno vations and retrofitting No computers no software no special training is required all you need is a screwdriver and you can install and configure the system Table of contents Switching a single channel SM1L SM1B SM1 AM1 AM1C Sensor with one digital 230V input Sensor with one digital input Actuator with one switched output Actuator with
2. SAMDR STO01 H01 EAN Number 4260194734037 AMD10V ST01 H01 EAN Number 4260194730091 AM1A AMXA LIN E i Vo oe N 2 AM1A ST04 H01 AMXA ST04 H01 EAN Number 4260194730015 46 SIENNA SYSTEM Switch ta the future DIM ACTUATOR Leading edge The SIENNA AMDR actuator is designed to dim and or switch incandescen lamps and conventional transformers The SIENNA AMDR actuator has one triac switched output for electrical devices up to 300W Loads up to 150W are allowed when the actuator is used with universal electronic transformers leading and trailing edge In overload conditions the actuator switches off automatically and can bq activated only after a predefined cooling phase 60s Output L N for connecting to electrical device One leading edge output rated at 300W cog 1 for dimming L N is bridged to the neutral of the power supply Operational modes 0 1 R L loads up to 300W cos 1 150W cos 0 6 2 Universal electronic transformers upto 150W Takes into account the min load requirements for universal transformers Dims in the range from 30 100 SENSOR DIM ACTUATOR combination Leading edge The SIENNA SAMDR module combines the SM1L sensor and AMDR actuator in a single module SAMDR has a 230V input and a triac switched output for electrical devices up to 300W Loads up to 150W are allowed when the actuator is used with universal electronic transformers leading
3. 18 Solutions SIENNA9 SYSTEM Switch To the future 1 Disable Enable exhaust fan s via window contact Installing a fireplace in an apartment is often associated with implementation of additional safety measures e g one needs to ensure that an adequate supply of fresh air is always available In most situations this implies that the exhaust fans in the apartment can only be operated when the windows are open SIENNA offers a solution which can be retrofitted in existing homes A SIENNA sensor attached to a magnetic contact at the window and actuators attached to the exhaust fans this makes the exhaust fans operational only when the window is open FIREPLACE SIENNA SM1 with 5V input connected to window contact SIENNA AM1 disconnects power supply to exhaust fan s 2 Disable Enable exhaust fans via boiler unit Similar to fireplaces the simultaneous operation of a boiler unit and exhaust fans in an apartment can lead to dangerous situations E g the exhaust fans drawing in the exhaust fumes from the boiler into the apartment can result in a life threaten ing situation SIENNA offers a solution which can be retrofitted in existing homes A SIENNA sensor connected to the output of the boiler and actuators attached to the exhaust fans this disables the exhaust fans until the boiler is turned on SIENNA SM1L connected to 230V output of boiler unit SIENNA AM1 disconnects power supply to exhau
4. The SIENNA SM1L R sensor has 230V input like SM1L One switched 230V output max 1A indicates the status of the corresponding actuator Operational modes Push each push triggers a switching action On Off 3 Way Input One digital input L 1 with 230V 50Hz Phase bridged to L Can also be used with illuminated switches Output Switched 230V output L N for displaying actuator status N is bridged to the neutral of the power supply Switching with SIENNA9 SYSTEM auxiliary functions Switch to the future Additional control point for a device SAM1LT switches OFF all actuators after a preset time interval Displaying actuator status via sensor Output of sensor SM1L R switches depending on actuator feedback and displays the actuator status Motor control amp central switching SM3 STO02 H02 EAN Number 4260194732064 SM3G ST09 H02 EAN Number 4260194732071 AM2 AMX2 h NN OF um ra P t i CES i gm n an 5 AM2 ST01 H01 AMX2 ST05 H01 EAN Number 4260194730053 114 SAM2 ST01 H01 EAN Number 4260194734020 SIENNA SYSTEM Switch ta the future SENSOR with three digital inputs The SIENNA SM3 sensor has three digital inputs which can be connected to a 2 gang or 3 gang switch Blind Shutter Up Down Stop Centralized switching functionality Master On Master Off can also be implemented with SM3 Potential free switching elements required I
5. e Configurable with a screwdriver e Includes a 5 Channel remote control for usage with all SIENNA actuators Technical Specifications Gateway 868 30 MHz FSK Outdoors 100 m indoors ca 30 m Easywave compatible with all Easywave remotes http www eldat de Maximum 32 RF Channels 230V 50 Hz power consumption max 1 5W 0 5W 25 C to 70 C EN 300 220 1 V1 3 1 2000 09 EN 300 220 3 V1 1 1 2000 09 Technical Specifications Remote See Gateway 5 RF Channels with On Up nnd Up Down buttons 1 x 3V Batteriy CR2032 20 C bis 60 Fi EN 300 220 1 V1 3 1 2000 09 EN 300 220 3 V1 1 1 2000 09 RFGS ST01 H01 EAN Number 4260194736017 14 Home automation SIENNA9 SYSTEM Switch ta the future SIENNA HOME for Home Automation and Remote Access SIENNA Home is a Web Server with an embedded application for controlling all SIENNA devices The SIENNA Home Controller is always on and can control SIENNA devices without an attached PC A PC with a web browser is required only while configuring the controller e Scenarios and Schedules can easily be configured using a browser All components can be controlled and monitored remotely using a PC or a mobile phone with an web interface m cunaano Processor eese RISC CPU 400MHZ230V 50Hz Network Interface 1 x 10 100 Ethernet Port USB POM 2
6. and trailing edge In overload conditions the actuator switches off automatically and can be activated only after a predefined cooling phase 60s Input One digital input L 1 with 230V 50Hz Phase bridged to L Can also be used with switches that integrate a indicator lamp Output See SIENNA AMDR Operational modes See SIENNA AMDR DIM ACTUATOR 1 10V The SIENNA AMD10V actuator can be used with electronic ballasts or other devices with a 1 10V interface to switch and or dim these devices The SIENNA AMD10V actuator has a current sink of max 30 mA and can switch up to 6 electronic ballasts connected in parallel Output Relay putput L for switching loads up to 10A N is bridged to the neutral of the power supply Output is a 1 10V output for dimming the load Output can have max 30mA when operated with several loads connected in parallel ACTUATOR for alternate switching The SIENNA AM1A AMXA actuator can either be directly attached to an electrical device or flush mounted behind a power outlet and is designed for alternate switching The actuator has two outputs with oppositely switched relays for electrical devices with current ratings up to 5A SIENNA AM1A 230V output L1 N L2 N to the devices electrical circuits L1 and L2 are oppositely switched outputs up to 5A The output terminals N are bridged to the neutral of the power supply SIENNA AMXA floating output X1 X X2 are
7. electrical devices at home via the internet E g the room temperature can be remotely controlled using a mobile phone so that one comes back from work to a warm and cosy home without wasting energy throughout the day a feature that is convenient and at the same time contributes towards a greener world Metal Housing ee ee ee pee HEATING UNIT SIENNA SMTEMP functions as the thermostat for regulating room temperature SIENNA AM switches the heating valve SIENNA Home for remote access 8 Scenes and Schedules Scenes and schedules that control the lighting heating motorized blinds or other electrical appliances in a home provide comfort and convenience help save energy and are an important part of an enhanced lifestyle In homes using conventional electrical wiring it can be a real challenge if not impossible to implement these additional features without expensive remodelling SIENNA offers a very simple solution a solution that can be retrofitted in all existing homes The SIENNA Home Server makes it possible to integrate any SIENNA actuator into a scene These scenes r wm can then be run individually or as part m ry m of a schedule via the SIENNA Home IM Sr Server The homeowner can create individual scenes schedules that turn Garden lights on and off adjust lighting levels Nem or open and close the blinds to create Name Good Moning the ideal mo
8. if switch is reactivated 0 Comfort switching for setting the slat angle of a sunblind shutter Man Motor runs only when switch is activated SIENNA AM2X actuator is similar to AM2 but with potential free outputs SENSOR ACTUATOR combination for motor control SIENNA SAM2 combines the SM3 sensor and AM2 actuator a single module SAM2 has 2 inputs for a blind control switch and 2 interlocked outputs motors with current ratings up to Run time can be set with SIENNA Professional default run time is 120s Input Three flexible wires for connecting to a switch Output N V for connecting to motor one relay each to switch A Down up to 5A N is bridged to the neutral of the power supply Operational modes 0 Motor runs to end position stops if switch is reactivated 1 Comfort switching for setting the slat angle of a sunblind shutter 2 Motor runs only when switch is activated 10 Motor control amp SIENNA9 SYSTEM central switching Switch the future Controlling sunblinds Actuator Motor control r Master switch g 0 also for timers and weather stations Control point with inputs outputs Panic switch Master OFF please refer to Wiring plans p 20 Address assignment e 0 Address assignment g 1 Address assignment g e 22 Controls all elements with identical g 11 AMD ST04 H02 EAN Number 4260194730084
9. switch reliably The sensor has an high input resistance connected to the 230V input 1 For cable lengths gt 10m between the switch and the input it may occur that the voltage at the connecting wire is not completely reduced to ground this results in the sensor not responding correctly Solution A load module connected to the sensor between the connecting wire Input 1 and ground reduces the voltage at the input so that the sensor can function correctly The motors attached to the motor actuators do not run smoothly The sensors used for motor control have low voltage inputs and they can only be connected to potential free switching elements Outputs e g timers that are not potential free have to be made potential free e g by using a interposing relay If the 230V output is directly connected to the sensor inputs the sensor will see a zero crossing every 10 msec and will try to start and stop the motor with the mains frequency Solution Connect the sensor inputs to potential free switching elements The actuator and the sensor do not communicate with each other even though they have identical addresses The SIENNA modules generate a domain area address during the installation process see section on Installation in the user manual Different domain addresses logically separate neighboring buildings areas from one another If the modules are configured in a sequence and not all together different domain addresses are ge
10. x USB 2 0 Powerline Interface LonWorks Powerline MEMOTY f SDRAM 64 MB FLASH 64 MB rr D Ethernet RJ45 with DHCP Server E U I EE PE PEE PE P E A AEA A Browser PC TV Mobile phone Operating System Linux Network Properties DHCP client HTTP server VPN ccena Home Automation Framework OSGi Framework JRE SRV HOME ST01 H01 EAN Number 4260194736000 15 Software SIENNA SYSTEM Switch To the future SIENNA Professional for installation and configuration SIENNA Professional is a Windows program for installing and configuring all SIENNA components and is designed for system integrators The PC based configuration can be used together with or as an alternative to the screwdriver based configuration This tool makes it very simple to change the configuration or to retrieve existing installations with a PC or a laptop The USB port of the PC is used to couple to the communication bus i e the powerline Any nearby power outlet can be used to access the powerline The coupling element PC power plug is included with the software package margen resa iata Acts muB cei Fal System requirements Laptop PC Intel Pentium Processor Operating System Windows XP Professional Home Vista 32 Bit Windows 7 32 Bi
11. F SIENNA SM3 with a push switch connected to input 1 Address 0 SIENNA SM3 with Master OFF switch connected to input 2 SIENNA AM1 AM2L actuators with address 1 2 3 4 etc are switched ON via the panic switch 20 Solutions SIENNA SYSTEM Switch To the future 5 Hot water supply New and old homes both waste large amounts of energy when hot water is supplied to the whole house In order for the hot water to be readily available throughout the house a circulation pump distributes hot water through pipes either continuously or on a timed basis e g 14 hours a day This results in a significant and completely unnecessary waste of energy It is possible however to save about 30 of the hot water bill by starting the circulation pump only on demand i e at the moment hot water is needed at a certain tap SIENNA offers exactly this solution which can be retrofitted in existing homes SIENNA sensors connected to standard switches near the hot water taps start the circulation pump only on demand A SIENNA actuator with a timer function lets the circulation pump run just long enough to provide hot water at all the taps typically less than a minute Approx 30 40s after pushing the switch hot water is available at the taps an easy way to save money and be friendly at the same time SAMILT with delay timet SIENNA SM1L R connected to wall switch in the bathroom kitchen the indicator
12. NNA AM1 actuator can either be directly attached to an electrical device or flush mounted behind a power outlet The SIENNA AM1 actuator has Output L N for connecting the electrical device One single pole relay rated at 10A to switch L N is bridged to the neutral of the power supply EL 0 pu one relay switched output for electrical devices with current ratings up to 10A L N E C A f Rang ess AM1 ST01 H01 EAN Number 4260194730008 ACTUATOR for On Off switching with current measurement 2 056 Similar to the SIENNA AM1 actuator but with additional current measurement NN a capability I Uy 1 Visualization and recording of current usage with SIENNA Professional L tei A flr ze Tan i e AM1C ST01 H01 EAN Number 4260194730039 Switching SIENNA SYSTEM single channels Switch to the future Controlling a remote device from multiple points 1 AMDR X C 0 E Switching SIENNA SYSTEM multiple channels Switch the future SM2 ST05 H02 EAN Number 4260194732026 SM2G ST011 H02 EAN Number 4260194732057 AM2L ST02 H01 AM2X ST06 H01 EAN Number 4260194730060 107 SMA SM8 SM4 ST01 H01 SM8 ST02 H01 EAN Number 4260194732118 25 SENSOR with two digital inputs The SIENNA SM2 sensor has two digital inputs internal 5V which can be connected to one 2 gang s
13. ations for cable feeds Package includes 1 base with locking clip 1 top cover DING H01 EAN Number 4260194737007 Technical Specs SIENNA flush mounted modules Technology Perilune communication in the Backbone 5Kb s compliant with FCC CENELEC EN50065 1 and LONWORKS Protocol Power Supply 230V 50Hz Power consumption 0 5W 1 5W via L connectors plus attached device wiielc lIlr o pe Neuron Processor integrated in Powerline Smart Transciever PL 3170 2 0 08mm2 1 5mm for all connecting cables Operating Temperature 25 C to 70 C Voltage Surge Protection Varistor Standby Power Consumption 0 5W xc T NN 300m connection length over all 3 phases up to 2km on a single Phase Safety Compliance CE EN60669 EN50065 1 Differences in connection length can occur due to presence of other electrical elements e g ground fault circuit interrupter Dimensions Front view Height 52 mm E 227 mm Inputs Outputs depends on module type Terminals Configuration switch depends on module type unu gp Pushbutton 17 Address Assignment SIENNA SYSTEM Switch ta the future All SIENNA elements have two rotary switches each with 16 positions for address assignment The fir
14. connected to the devices X1 and X2 are oppositely switched outputs with an external potential X up to 5A 12 Dimming SIENNA SYSTEM Switch To the future Dimmer control SM1L or SM1 Requlating a motor e g pump for a water fountain L L N N ON Higher IX rc Pump e g for a OFF water fountain Lower EXE o Please note that the pump needs to work together with a leading edge dimmer 13 SIENNA SYSTEM Switch To the future Home automation THERMOSTAT SIENNA SMTEMP room temperature controller with temperature sensor and continuos action controller compatible with front panels from Berker Gira Merten Jung und Peha Model SAMTEMP ST02 H02 has additional floating SMTEMP SAMTEMP switched outputs Input Potentiometer for setting the temperature Output SIENNA SAMTMP ST02 H02 with two switched outputs 2 oppo sitely switched potential free relays SMTEMP ST01 H02 SAMTEMP ST02 H02 EAN Number 4260194732088 4044 SIENNA RFGS Wireless gateway inc wireless remote for all SIENNA actuators SIENNA RFGS is a gateway for mapping wireless channels to SIENNA powerline devices e Plug in module with RF Receiver SIENNA Powerline output Compatible with all Easywave RF transmitters e g remote control or door window contacts e 32 configurable RF Channels
15. ed to multiple switches This sensor can switch up to 4 different actuators Operational Modes Push each push triggers a switching action On Off Off On Input Four digital internal 5V inputs 0 1 2 3 4 with flexible connecting wires which can be connected to a single multiple gang switch or to four separate switches SIENNA SM8 sensor is similar to SM4 but has 8 digital inputs for 8 channels Switching SIENNA SYSTEM multiple channels Switch to the future Combining 1 channel and 2 channel modules Address assignment g e Address assignment g e Address assignment g e 1 Sensor 2 channel switches 2 channel actuators and or 1 channel actuators L jH of N Address assignment 9 Address assignment 9 1 Controlled via 1 sensor 2 channel and or 2 sensors 1 channel Carrying forward a 3 Way contact L Fm Tm LNA Ml Switching with SIENNA SYSTEM auxiliary functions Switch to the future SAM1L ST01 H01 EAN Number 4260194734006 SAM2L ST03 H01 EAN Number 4260194734051 SAMTLT SAM1LT ST03 H01 EAN Number 4260194734013 SM1LR ST02 H01 EAN Number 4260194732095 SENSOR ACTUATOR combination SIENNA SAM1L combines the SM1L sensor and AM1 actuator SAM1L has one 230V input and one switched output for loads up to 10A The input can be connected to a light switch or to other switching e
16. lamp is on when the circulation pump is on SIENNA SAM1LT to control the circulation pump 6 Motion detectors and indoor lighting In the 70s motion detectors connected to the outdoor garden lights were a standard way of preventing intruders from break ing in to empty homes Nowadays this offers minimal protection against intruders and advanced features such as presence simulation are necessary to effectively prevent break ins But how does one retrofit a presence simulation mechanism in an existing home without expensive remodelling SIENNA offers a solution which can easily be retrofitted in existing homes All you need is a SIENNA sensor connected to the motion detector triggering the outdoor lighting and a SIENNA actuator connected to a lamp inside the house As soon as the motion detector is triggered it switches on a light inside the house an ingeniously simple way of simulating presence in the home Motion detector xT Dp for motion detector SM1B SIENNA SM1B or SM1L connected to the output of the motion occupancy detector SIENNA AM connected to an indoor light 21 Solutions SIENNA9 SYSTEM Switch To the future 7 Room temperature control via a mobile phone SIENNA Home offers the possibility to control and monitor the heating lighting etc at home from anywhere and at anytime and this can be retrofitted in all existing homes The SIENNA Home Server can be used to remotely access the
17. lements e g motion detector thermostat etc Operational modes Push each push triggers a switching action On Off 3 Way Input One digital input L 1 with 230V 50Hz Can also be used with illuminated switches Output L N connected to electrical device One relay rated at 10A to switch L N is bridged to the neutral of the power supply SENSOR ACTUATOR combination with 2 channels SIENNA SAM2L has two relay switched outputs for switching 2 separate devices with current ratings up to 5A The inputs with flexible wires can be direclty connected to a 2 gang switch Operational modes Push each push triggers a switching action On Off 3 Way Input Three flexible wires for connecting to a switch Output Output terminals A and V for connecting to devices 1 and 2 N is bridged to the neutral of the power supply SENSOR ACTUATOR combination with timer SIENNA SAM1LT includes a time delayed switching functionality in addition to the SAM1L module e g for hallway lighting Delay time can be set within a range of 1 Min to 2 Hrs Operational modes Push each push triggers a switching action On Off 3 Way Input One digital input L 1 with 230V 50Hz Phase bridged to L Can also be used with illuminated switches Output L N connected to electrical device One relay rated at 10A to switch L N is bridged to the neutral of the power supply SENSOR with actuator status display
18. nerated and the modules do not communicate with each other Solution Reset all modules by using the RESET button and then configure all modules in a single installation process see section on Installation in the user manual 23 THE HOME CONTROL COMPANY Secyourit GmbH January 2010 Auenstr 100 80469 Munich Germany Tel 49 89 384 66 481 Fax 49 89 724 300 99 Email info secyourit com Web www secyourit com
19. nput Three binary internal 5V inputs 0 1 2 3 0 Common ground 1 2 Up Master switch On Down Master switch Off 3 as defined by operational mode Operational mode for input 3 sliding switch Aus Ein Go up and stay blocked as long as input 3 is active e g wind sensor Ein Aus Biased off switch independent of actuator setting Input 3 as in Aus Ein Taster Additional stop functionality SENSOR for switching multiple groups The SIENNA SM3G sensor has three digital inputs which can be connected to a 2 gang or 3 gang switch Blind Shutter Up Down Stop Centralized switch ing functionality Master On Master Off can also be implemented with SM3G The SM3G switches actuators which have consecutive group addresses e g C switches actuators in groups C amp D The second group is switched with a time delay of 1s Input SeeSM3 Operational mode for input 3 sliding switch See SM3 AKTOR for motor control The SIENNA AM2 actuator can be directly mounted to a motor AM2 has relay switched output for motors with current ratings up to 3A The outputs are interlocked such that only one output can be active at any time Run time can be set with SIENNA Professional default run time is 120s Output L1 N L2 N for connecting to motor one relay each to switch L1 L2 Up Down up to 5A N is bridged to the neutral of the power supply Operational modes Auto Motor runs to end position stops
20. od for television viewing rum a entertaining around the dinner table Coo e Q aro outdoor living Another advantage of VENE E ES vB VES living in a smart home SIENNA Home for defining and running scenes and schedules SIENNA modules for controlling the devices 22 FAQ SIENNA9 SYSTEM Switch To the future How does SIENNA work SIENNA sensors and actuators use the 230V powerline as a communication bus The components can communicate over all 3 phases without any phase couplers or other central units Any sensor can control any actuator within a building independent of the actual electrical wiring This combines the flexibility of wireless system with the reliability of a wired system What is the range of the SIENNA components The range is typically 300m cable length between the sensor and actuator independent of the ac tual phase The components do not require additional phase couplers or frequency filters A three phase current cable typically connecting the electricity meter and power distributor or the connection to the cooking range is sufficient for the phase coupling In cases where the sensor and actuator are on the same phase then the range extends upto approx 2 km Why does SIENNA not require phase couplers SIENNA components communicate via the powerline and this communication works over all 3 phases without the use of additional phase couplers A three phase current cable t
21. one switched output with current measurement Switching multiple channels SM2 SM2G AM2L AM2X SM4 SM8 Sensor with two digital inputs Sensor with two digital inputs for switching multiple groups Actuator with two switched outputs Sensor with digital inputs for 4 to 8 channels Switching with auxiliary functions SAM1L SAM2L SAMTLT SM1L R Motor control SM3 SM3G AM2 AMX2 SAM2 Sensor Actuator with one switched output and one 230V input 2 Channel switch actuator with inputs Sensor Actuator with timer for delayed switching Sensor with actuator status display Sensor with three digital inputs for motor control Sensor with three digital inputs for controlling motors in multiple groups Actuator with two interlocked outputs for motor control Sensor Actuator for motor control Dimmer Toggle Actuators AMDR SAMDR AMD10V AM1A AMXA Home Automation SIENNAG Home SMTEMP SAMTEMP RFGS Configuration SIENNA Professional Accessories Technical Data Actuator with one Triac output for dimming Leading edge Sensor Actuator with one input for dimming Leading edge Actuator with 1 10V interface for dimming Toggle actuator with two oppositely switched outputs Controller for home automation and remote access Thermostat Wireless gateway inc wireless remote for all SIENNA actuators Configuration software for SIENNA modules Address assignment Applications FAQ SIENNA SYSTEM Switch To the fut
22. st fan s 19 Solutions SIENNA9 SYSTEM Switch To the future 3 Temperature control Floor heating SIENNA offers a solution for regulating the temperature in each room separately a solution that can be retrofitted in existing buildings SIENNA sensors with conventional thermostats are installed at an appropriate place in each room and SIENNA actuators are connected to the appropriate heating valves Each thermostat can now control the corresponding heating valve and regulate the floor heating individually in each room A measure of extra comfort that not only saves on heating bills but also contributes towards a greener world Metal housing m THERMOSTAT Pew RADIATOR SM1L SIENNA SM1L connected to thermostat output SIENNA AM1 switches heating valve 4 Panic switch Master OFF SIENNA allows one to easily retrofit a panic switch in existing homes SIENNA sensors connected to the existing light switches and one central sensor is sufficient to activate the panic switch feature If necessary the shades blinds can also be raised when the lights are switched on With SIENNA and with minimum effort one can easily enhance security and sleep peacefully at night Master switch SIENNA9 SM3 Push switch connected to input 1 switches ON all actuators Panic switch Master switch SIENNA SM3 Push switch connected to input 2 switches OFF all actuators Master OF
23. st rotary switch sets the group address g to an alphabetic value A B P The second rotary switch sets the element address e to a numerical value 0 1 15 Arbitrary many elements can have identical g and e All elements with identical g e switch simultaneously Group address g indicates a particular group E g all sunblinds have identical g different e Element address e e Sensors with e 0 control all actuators with identical g regardless of e e g centralized control of sunblinds 015 a master switch e g sensor connected to wind detector has the address 9 e 0 this sensor controls all sunblinds with identical g and arbitrary e Scheme 3 Way switching Arbitrary many sensors and actuators can have identical addresses In this case each sensor controls all actuators E g Each of the 3 sensors switches 2 actuators Switch Appliance Scheme Master Switch The address g e 0 defines a sensor to be a master switch This sensor controls all actuators with identical g Note The address e 0 defines the master switch to be a On Off switch regardless of the position of the sliding switch This implies that for a push switch one position is defined as ON and the other as OFF Switch Appliance Master Switch g e 1 1 e M g e 1 2 9 2 g e A2 g e 2 g 3 53 9 e 3 g 3 53
24. t Hard disk 20 MB available space on hard disk 64 Screen Resolution 1024 x 768 Interface USB 1 1 or 2 0 Technical Specifications coupling element Technology Powerline communication in the B C Band 5kb s compliant with FCC CENELEC 50065 1 and LONWORKS protocol Bus Power plug 230V 50Hz PC Colplilig ioa USB 1 1 or 2 0 Operating Input Current Power supply Power plug 250 mA maximum 18VDC j USB 50 mA maximum 5VDC 0 Neuron processor integrated in the Powerline Smart Transceiver PL 3120 Operating temperature 25 C to 70 C i Safety compliance CE EN55022 Class B EN55024 ETSI300 019 2 3 T3 2 T V x EN60950 SW PROF ST01 H02 EAN Number 4260194736048 16 Accessories SIENNA9 SYSTEM Switch To the future DIN Rail Housing DIN rail housing for all SIENNA flush mounted modules Housing corresponds to DIN 43 880 size 1 Simple and quick assembly by locking onto DIN rails EN 60 715 TH 35 Base part with fixing towers Top part with ventilation slots Vertical and horizontal guides for additional PCBs Locking lid for protecting the display and operating elements Model With perfor
25. ure 10 12 14 16 17 17 18 19 23 Switching SIENNA SYSTEM single channels Switch to the future SM1L SM1B SENSOR with 230V input The SIENNA SM1L sensor has 230V input The input can be connected to a light switch or other switching elements e g motion detector thermostat etc For optimized wiring L N can be extended via the additional terminals L N Operational Modes Push Each push triggers a switching action On Off 3 Way Input One digital input L 1 with 230V 50Hz Phase bridged to L Can also be used with switches that have an integrated status lamp SIENNA SM1B for motion detectors with continuous operation feature SM1L ST01 H02 SM1B ST04 H02 Continuos on Continuous off EAN Number 4260194732019 101 SENSOR with 5V internal input The SIENNA SM1 sensor has one 5V input which can be connected to a switch On Off Off On or a push switch dimmers amp motors Connection to magnetic contacts or 0 08mm2 cables is also possible with the internal 5V input Potential free switching elements are required Operational Modes Push Each push triggers a switching action On Off Off On Input One digital input 0 1 for connecting to a switch push switch or magnetic contact 5V Input can also be used with 0 08mm connector cables Max cable length to switch 10m SM1 ST06 H02 EAN Number 4260194732002 ACTUATOR for On Off switching The SIE
26. witch or to two separate switches This sensor switches 2 actuators with addresses g e and g e 1 Potential free switching elements required Operational Modes Push each push triggers a switching action On Off Off On Input Two digital internal 5V inputs 0 1 2 connecting to a 2 gang switch or to 2 switches SENSOR with digital inputs for switching multiple groups The SIENNA SM2G sensor has two digital inputs internal 5V which can be connected to one 2 gang switch or to two separate switches This sensor switches 2 groups g e and g 1 e Potential free switching elements required Operational Modes Push each push triggers a switching action On Off Off On Input Two digital internal 5V inputs 0 1 2 connecting to a 2 gang switch or to 2 switches ACTUATOR with two outputs The SIENNA AM2L actuator can either be directly attached to an electrical device or flush mounted and is designed for switching two separate devices or electrical circuits AM2L has two relay switched output for loads up to 5A Output L1 N L2 N to the devices electrical circuits one relay each to switch up to 5A on L1 L2 The output terminals N are bridged to the neutral of the power supply The SIENNA AM2X actuator is similar to AM2L but has potential free outputs SENSOR with digital inputs for 4 to 8 channels The SIENNA SM4 Sensor has four digital inputs internal 5V which can be connect
27. ypically connecting the electricity meter and power distributor or the connection to the cooking range is sufficient for the phase coupling Why does SIENNA not require frequency filters During installation the SIENNA components generate a domain or building address via a paten ted process As a result neighboring buildings are logically separated from each other preventing any interference How many SIENNA nodes can you install in a single building Up to 200 SIENNA nodes can be installed in a single building In case the no of nodes is greater than 200 a slight delay may be observed during execution of switching commands s SIENNA compatible with other bus systems SIENNA uses the LON Standard and is compatible with other LonWorks based systems Echelon s LonWorks is a ISO IEC and ANSI compliant platform that enables some of the world s most advanced control and energy management applications Normally LonWorks is used for commercial buildings and for big projects e g Munich Airport the Reichstag in Berlin the new trade fair center in Stuttgart etc SIENNA is the first system that offers LonWorks based products for residential buildings Troubleshooting An actuator does not respond to commands from the sensor In most cases the addresses rotary switches are not identical Solution The addresses can be changed corrected via the rotary switches No reset is necessary A sensor with a 230V input does not

Download Pdf Manuals

image

Related Search

Related Contents

Please read manual carefully before starting  HP D3K52UT User's Manual  The DataLog system is comprised of 2 main components – the  EM-2260/EM-2260 Development Kit User`s Manual  ASSMANN Electronic AK-510400-002-W cable splitter or combiner  LeakDetector  Sony ICF-CS15iPBLK Cautions  梅毒TP抗体スクリーニング検査の再評価 当検査室では    