Home

Newton - Techni-Lux

image

Contents

1. dimmer Newton Channel 3 controls the linear dimmer On Newton Control the adjustment occurs through the relevant control and is conti nuous on a scale of 0 to 100 The ON key opens or closes the shutter which blocks the luminous beam while the FLASH key allows aperture at the value set with the slider with return to the star ting value when the key is released ch 4 shutter strobe Newton Channel 4 controls the shutter strobe On Newton Control the adjustment occurs through the relevant control and is conti nuous on a scale of 1 to 12 fps flashes per second The ON key activates the strobe while the FLASH key allows instantaneous activa tion of the strobe at the desired frequency deactivating it when the key is relea sed ch 2 5 colour colour mode red ie green yan magenta yellow white auto white red blue green cyan magenta yellow white H 70 rpm 47 es e 99 67 45 A bicolour rainbow HERE C O CDD CD CED ween one colour and EEA _ on 100 90 20 E 60 180 40 50 R flash on appendice 12 fps 9 4 N ZARE 85 RER i She it flash SIGIMI page 5 SIGIM LIGHT TECHNOLOGY Via Pio La Torre 1 61010 TAVULLIA PS e ITALY e Tel 39 0721476477 amp Fax 39 072147617
2. in February 1998 Rel 1 02 General Characteristics Newton Control is a dedicated control unit for the intelligent Newton spotlights Its simplicity of use makes it suitable for any type of application since it allows much more rapid more simple and more precise control than occurs with controls fixed to the projector body and can also be carried out at a considerable distance from the projector The vast and pluridecennial experience of SGM in the sector of light control systems has allowed developing a product with high reliability and precision thanks to the absolute mastery of the know how and the optimisation of the quality price relation Newton Control is supplied directly from the projector to which it is connected and does not require any other connections Technical Characteristics POWER SUPPLY 14V DC 350mA ABSORBED POWER BW ELECTRONICS Entirely developed by the SGM Research amp Development Laboratory Equipped with a mother board CS 0190 CONTROL SYSTEM Newton Control controls 5 DMX channels corresponding to the following Newton projector functions ch 1 iris ch 2 colour ch 3 dimmer ch 4 strobe ch 5 colour mode BODY Milled and shaped wood Epoxy powder enamelling DIMENSIONS 40 5 x 28 5 x 5 cm weight 3 9 kg professional followspot controller magenta yellow FE i e e e e e white auto bicolour rainbow on ES D D DD oere SIGIMI page 3 SIGIMI page 4 Newton Control Connectio
3. 0 www sgm it e info sgm it cod M001180
4. SIGIM LIGHT TECHNOLOGY i AC roba 6 9 user manual Newton professional followspot controller rel 1 02 General warnings Carefully read the warnings contained in this manual since they supply important instructions concer ning safety of installation use and maintenance It is very important that this manual be kept with the equipment for future consultation In case of sale or transfer of the equipment to another user ensure that this manual always accompanies the equipment to allow the new owner to obtain information about the operation and the relevant warnings e After unpacking check the integrity of the equipment In case of doubt do not use the equipment and contact an authorized SGM Technical Service Centre The packaging materials plastic bags expanded polystyrene nails etc must be kept out of reach children since they are potential sources of danger his equipment may only be operated by adults Do not allow children to tamper with the machine r play with the product ectrician or by a competent person efore connecting the unit check that the data on the registration plate is the same as that of the ectrical grid O T o e The electrical work necessary for the installation of the equipment must be carried out by a qualified e B e e Avoid using the equipment in places subject to excessive humidity in places subject to vibrations or knocks in places with temperatur
5. es higher than 45 C or lower than 2 C Protect the equipment from excessively humid conditions the optimum values are between 35 and 80 e Do not disassemble or modify the equipment e Prevent inflammable liquids water or metallic objects from penetrating the equipment e Incase of spilling liquid on the equipment immediately disconnect the power supply of the mixer e The minimum distance between the projector and the surface to be illuminated must not be less than 1 5 m e In case of serious functioning problems switch off the equipment and contact the nearest SGM retailer or the manufacturer directly for inspection e Avoid opening the equipment there are no parts repairable by the user e Never try to repair the equipment alone Repairs carried out by inexpert persons may cause damage or serious malfunctioning Contact the nearest authorised Technical Service Centre Always insist on original spare parts Protect the environment do not throw the packaging in your dustbin but return it to your retailer or take it to a collection point for special waste disposal EB D D DD DD vie SIGIMI page 1 SIGIMI page 2 Index a an 0 A Aa A OW OW N General warnings Index General Characteristics Technical Characteristics Newton Control Connections Newton Control Commands ch 1 iris ch 2 ch 5 colour colour Mode ch 3 dimmer ch 4 shutter strobe SIGIM LIGHT TECHNOLOGY Made in Italy by SGM Electronic Printed
6. mands im 100 90 80 70 160 50 40 40 20 EL ch 1 iris Newton Channel 1 controls the iris diaphragm On Newton Control adjustment occurs through the relevant control and is continuous on a scale of 0 to 100 The ON key opens or closes the luminous beam while the FLASH key allows aper ture from the value set with the slider up to maximum with return to the starting value when the key is released min on flash Newton Channel 2 controls the colours and operates in combi nation with channel 5 colour mode On Newton Control the colour controls are grouped and arran ged in a simple and intuitive manner The red blue green blackout from one pos The AUTO key autom cyan magenta yellow and white keys give direct access to the relevant colour with passage to ition to the next atically activates the colour change with blackout mode hard change BICOLOUR controls the two colour mode whose indications are shown on the sca e to the left of the adjustment slider In this way pressing the colour keys also activates the change between adjacent colours The slider moreover g the next The RAINBOW mode is activated through the relevant key The rotation speed of the colour wheel is shown to the right of the adjustment slider variable from 2 4 to 70 rpm ives access to analog colour control and the passages be ch 3
7. ns Newton Control is connected to the Newton spotlight through the DMX 512 input socket The control unit is fitted with a special connection cable The Newtons allow cascade connection and can thus be controlled in classic DMX or RS 232 chains Therefore the operator is not required to control the functions transferred to the controller or the light desk and can concentrate on the movement quality When using a different controller or a light desk the projectors must be suitably addressed see the following diagrams while when using the dedicated Newton Control all the projectors must be addressed to channel 001 In the first case the Newtons are independent while in the second case they are all under the same controls The Newtons supply power directly to the Newton Control unit using the pins 4 and 5 of the DMX IN socket see following diagrams When implementing systems using these two socket pins always bear this in mind in order to pre vent damage to the projector or the units connected to it socket pin out output signal main power input Oe EEn En 3 pin 1 pin 2 pin 3 pin 4 pin 5 5 4 comm DMX DMX comm 14vDc RS 232 RS 232 Newton amp Newton Controller ms FE AAAA nn Newton 1 start address 001 Newton 2 start address 001 Newton 3 start address 001 Newton Control Com