GPIB to USB Adapter
Contents
1. DTO Device This device has no Device Trigger Trigger interface function C0 Controller This device can not control other devices 14 GW INSTEK APENDIX Miscellaneous Current Less than 0 5 ADC from 5V Consumption Operating Ambient temperature 0 50 C Environment Relative humidity lt 80 40 C or below lt 45 41 C 50 C Storage Storage Temperature 10 C 60 C no condensation Relative humidity 93 40 C 65 41 C 60 C Altitude Up to 2 000 meters Dimensions Approximately 8 6 L x7 5 W x3 3 H cm 15
2. GPIB to USB Adapter GUG 001 USER MANUAL GW INSTEK PART NO 82UG 00100Mo1 pzd ISO 9001 CERTIFIED MANUFACTURER 2 GWINSTEK This manual contains proprietary information which is protected by copyright All rights are reserved No part of this manual may be photocopied reproduced or translated to another language without prior written consent of Good Will Corporation The information in this manual was correct at the time of printing However Good Will continues to improve its products and therefore reserves the right to change the specifications equipment and maintenance procedures at any time without notice Windows is a registered trademark of Microsoft Corp U S A NI 488 2 Measurement and Automation Explorer MAX are registered trademarks of National Instruments Corp U S A Good Will Instrument Co Ltd No 7 1 Jhongsing Rd Tucheng City Taipei County 236 Taiwan GW INSTEK SAFETY INSTRUCTIONS Table of Contents SAFETY INSTRUCTIONS cece eee ee 4 Safety Symbols xcoxcansnesovecsscnvestesaeecncteehecntereouasiecntonseuaninevennacent 4 Safety Guidelines ccssccsscssrssssccsssscscsssscssesenscessrseneees 5 GETTING STARTED 0 cece ec cece esc eeceee 7 Maim PS SS oerein crease sta EEA EERTE ERTER 7 Instrument OvervieW sssssssssssssssssesseeecrrsssssseescsessseseeereee 8 GOO EEPE PEA A LTE A ETTE A AS E A 8 OPERATION aoe green ccacccteacvcasesoensstecetotasseeaesecanccs 9 Se AT o
3. ator lt The ready indicator lights when the adapter is ready to use GW INSTEK OPERATION OperATION GDS 3000 Set Up Procedure 1 Connect a GPIB cable from a GPIB C controller to the GPIB port on the J adapter 2 Connect the USB cable from the rear panel device port typeB SS receptacle on the oscilloscope to gi the USB port type A receptacle on the GPIB to USB adapter Type A plug From computer Type B plug for GDS 3000 series 3 The Ready Indicator should be lit after the USB cable is connected Configure GPIB 1 Press the Utility key on the GDS po Utility 3000 front panel 2 Press I O from the bottom menu m GW INSTEK GUG 001 User Manual Limitations Use the variable knob to set the Press USB Device Port from the side menu and choose Computer Press GPIB from the side menu GPIB address from the side menu O Range 1 30 Only the GDS 3000 can be used to change the GPIB address from the default GPIB address of 1 GPIB secondary addresses are not supported Trouble Shooting If the Ready indicator will not come on 10 Check that the cables are correctly inserted Ensure the USB device powering the adapter is turned on and is functioning correctly GW INSTEK OPERATION Function Check Steps To check that the GPIB connection is working National Instruments Measurement amp Automation Expl
4. e adapter Avoid severe impact or rough handling that may damage the adapter Use only mating connectors not bare wires for the interface ports A soft cloth dampened in a solution of mild detergent and water can be used to clean the case Do not spray any liquid into the instrument Do not use chemicals containing harsh products such as benzene toluene xylene and acetone Location Indoor no direct sunlight dust free almost non conductive pollution Note below Relative Humidity lt 80 40 C or below lt 45 41 C 50 C Altitude lt 2000m Temperature 0 C to 50 C GW INSTEK GUG 001 User Manual Pollution Degree EN 61010 1 2001 specifies pollution degrees and their requirements as follows The instrument falls under degree 2 Pollution refers to addition of foreign matter solid liquid or gaseous ionized gases that may produce a reduction of dielectric strength or surface resistivity e Pollution degree 1 No pollution or only dry non conductive pollution occurs The pollution has no influence e Pollution degree 2 Normally only non conductive pollution occurs Occasionally however a temporary conductivity caused by condensation must be expected e Pollution degree 3 Conductive pollution occurs or dry non conductive pollution occurs which becomes conductive due to condensation which is expected In such conditions equipment is normally protected against exposure to direct sunli
5. eee ee ee ee eee eee ee ee ee ee 9 Funcion CACC oasis ase dee ges cc denen AES 11 APPENDIX aires ttt oss nnne EEE ELO 14 GUG 001 Specifications ssssssesessesesessesessrsiserseserrererees 14 GW IiINSTEK GUG 001 User Manual SAFETY INSTRUCTIONS This chapter contains important safety instructions that should be followed when using the GPIB to USB adapter Read the following before any operation to ensure your safety and to keep the adapter in the best condition Safety Symbols These safety symbols may appear in this manual or on the instrument AN Warning Identifies conditions or practices that WARNING could result in injury or loss of life N Caution Identifies conditions or practices that CAUTION could result in damage to the instrument or to other objects or property Attention Refer to the Manual Protective Conductor Terminal Earth Ground Terminal Do not dispose electronic equipment as unsorted municipal waste Please use a separate collection facility or contact the supplier from which this instrument was purchased bf O gt A GW INSTEK SAFETY INSTRUCTIONS Safety Guidelines General i Guideline caution Cleaning the instrument Operation Environment Do not use the adapter in a damp environment or where there is risk of explosion e Do not use the adapter with the case open The adapter is for indoor use only Do not place heavy objects on th
6. ght precipitation and full wind pressure but neither temperature nor humidity is controlled Storage e Location Indoor environment e Storage Temperature 10 C 60 C no condensation e Relative Humidity 93 40 C 65 41 C 60 C Disposal Do not dispose this instrument as unsorted municipal waste Please use a separate collection asd facility or contact the supplier from which this instrument was purchased Please make sure discarded electrical waste is properly recycled to reduce environmental impact GW INSTEK GETTING STARTED G ETTING STARTED The Getting Started chapter introduces the features functions and appearance of the GUG 001 GPIB to USB adapter Main Features The GW Instek GPIB to USB adapter is used to connect a GPIB controller to the USB B receptacle on the GDS 3000 as the scope does not have a GPIB interface The GUG 001 GPIB to USB adapter is currently only supported on the GDS 3000 Features e Enables GPIB control of the GDS 3000 via the USB B receptacle e No power adapter all power requirements from USB e The GPIB primary address can be assigned via the GDS 3000 Accessories e User manual USB type A B cable GW INSTEK GUG 001 User Manual Instrument Overview GUG 001 USB Type A Ready Inidcator Receptacle GPIB Port GPIB Port oc o 24 pin female GPIB port USB Type A USB type A receptacle connects to Receptacle the GDS 3000 type B receptacle Ready Indic
7. lies Ta ake Hap irim p AES A a GEET za O ie re ir PiN bev Pern en ae tie lim Beore b gt Metal I mea itl Wheat de pew 5 mF O iE dal N i F _ aiia Ei i reoi inia hirr F Dg L t PIT hart rune Fairge Ej ite a vA Popes 10 The function check is complete 13 GW IiINSTEK GUG 001 User Manual pen DIX GUG 001 Specifications USB Specification USB Device USB 2 0 full speed device interface GPIB Specification The GPIB interface of this device corresponds to the standard of IEEE488 1 1987 IEEE488 2 1992 The GPIB interface functions are listed as following SH1 Source This device can transmit multilane Handshake messages across the GPIB AH1 Acceptor This device can receive multilane Handshake messages across the GPIB T6 Talker Talker interface function includes basic talker serial poll and un address if MLA capabilities without talk only mode function L4 Listener This device becomes a listener when the controller sends its listen address with ATN attention line asserted This device dose not have listen only capability SRO Service This device has no SRQ Service Request Request function RLO Remote Local This device will ignore the LLO local lockout command PPO Parallel Poll This device has no Parallel Poll interface function DC Device Clear This device has Device Clear capability to return the device to power on status
8. orer MAX can be used The following function check is based on version 4 6 2f1 For further information about National Instruments please see the NI website at Wwww ni com 1 Complete the setup procedure Page 9 described previously 2 Start the Measurement and Automation Explorer MAX program Using Windows press Start gt All Programs gt National Instruments gt Measurement amp Automation ni com Measurement amp Automation Explorer Version 4 6 2 Initializing Copyright 1999 2009 Natit anal Ins rumen ts All rights reserved The Measurement amp Automation Explorer initial splash screen 11 GW INSTEK GUG 001 User Manual 3 From the Configuration panel access My System gt Devices and Interfaces gt GPIB0 GPIB USB B 4 Press the Scan for Instruments button 5 In the Connected Instruments panel the oscilloscope should be detected as Instrument 0 with the address the same as that configured on the scope 6 Double click the Instrument 0 icon 7 Click on Communicate with Instrument 8 In the NI 488 2 Communicator window ensure IDN is written in the Send String text box Click on the Query button to send the JIDN query to the oscilloscope 12 GW INSTEK OPERATION 9 The String Received text box will display the query return GW GDS 3XXX PXXXXXX V1 XX manufacturer model serial number version is foePigeiations FE erate cit a i jr tates i
Download Pdf Manuals
Related Search
Related Contents
Manual do Secretário Escolar - Conselho Estadual de Educação Kenwood KDC-MP4023 CD Player User Manual Commercial Electric RB063-P3 Installation Guide Spécialiste des questions politiques, P3 SW DVI A Series User`s Manual Handbuch Melissa 271-107 User's Manual Bedienungsanleitung MMGen2D_M_elliptic 2D elliptic and algebraic Mesh USER MANUAL Evolve 512 Delta Copyright © All rights reserved.