1. Set EAN UCC Composite Label ID Character s DEFAULT SETTING FOR THIS FEATURE P 5000 hex Set Datamatrix Label ID Character s a Default setting exceptions for PDF 417 Label ID are as follows Default for RS 232 WN is Q 0x5100 Default for USB HID POS is P 0x5020 or P Space 70 Magellan 1100i Label ID Label ID cont For the 2D symbologies on this page the Label ID is 4 bytes The first 3 bytes are characters for the label ID A 00 hex value in the first 3 bytes indicates the end of the label ID characters The 4th byte is a control byte NOTE The use of the control byte is as follows bit 0 if set to 1 the AIM Id is appended for that label type PROGRAMMING BARCODES II Set Micro PDF 417 Label ID Character s DEFAULT SETTING FOR THIS FEATURE mP 6D500000 hex DEFAULT SETTING FOR THIS FEATURE QR 51520000 hex x Set Maxicode Label ID Character s DEFAULT SETTING FOR THIS FEATURE MC 4D430000 hex Set Aztec Label ID Character s N DEFAULT SETTING FOR THIS FEATURE Az 417A0000 hex Set GS1 DataBar Omnidirectional 2D Composite Label ID Character s DEFAULT SETTING FOR THIS FEATURE R4 52340000 hex Set GS1 DataBar Limited 2D Comp
2. FAULT SETTING FOR THIS FEATURE F 46 Set ISBN Label ID Character s Set EAN 13 w C128 Addon Label ID Character s DEFAULT SETTING FOR THIS FEATURE I 49 hex DEFAULT SETTING FOR THIS FEATURE IA 4941 hex Set GTIN Label ID Character s Set IATA Label ID Character s DEFAULT SETTING FOR THIS FEATURE G 47 hex DEFAULT SETTING FOR THIS FEATURE G2 4732 hex Set GTIN w P2 addon Label ID Character s Set GTIN w P5 addon Label ID Character s DEFAULT SETTING FOR THIS FEATURE G5 4735 hex 68 Magellan 1100i Label ID Label ID cont PROGRAMMING BARCODES DEFAULT SETTING FOR THIS FEATURE G8 4738 hex Set GTIN w C128 addon Label ID Character s FAULT SETTING FOR THIS FEATURE R4 5234 hex Set GS1 Omnidirectional Label ID Character s Set GS1 Expanded Label ID Character s DEFAULT SETTING FOR THIS FEATURE 524C0000 hex T SETTING FOR THIS FEATURE RX 5258 hex Set Code GS1 DataBar Li
3. Quiet Zones This feature enable disables the requirement that quiet zones must be present for Codabar bar codes Don t require Quiet Zones DEFAULT 130 Magellan 1100i Codabar Codabar continued Start Stop Character Type Codabar has four pairs of Start Stop patterns Select one pair to match your application DLL Im WOW sa yo an Mian D DEFAULT Start Stop Character Transmission The transmission of start and end characters of Codabar is selected below START END PROGRAMMING BARCODES Wi ANAN Disable Start Stop Char Transmission Enable Start Stop Char Transmission DEFAULT Product Reference Guide 131 Symbologies Start Stop Character Match This feature enables disables the requirement that start and stop characters match Disable Start Stop Char Match DEFAULT Codabar Stitching Enables disables stitching for Codabar labels When parts of a Codabar label are presented to the scanner with this feature enabled the barcode parts will be assembled by the scanner s soft ware and the data will be decoded if all barcode proofing requirements are met 7 Only functions when Fixed Length Decoding is enabled NOTE ROGRAMMING BARCODE Po PROGRAMMING BARCODES Disable Codabar Stitching DEFAULT 132 Magellan 1100i Codabar C
4. 144 Disable Enable Standard 2of5 itt rete tte FE pate eH UNE GG GAGA 144 Check Digit Verification 144 Check Digit Transmit 145 Length Control ae a ott HERO DER te iR 146 Standard 2 of 5 Length 1 Length 2 Programming Instructions sssssssssssssesssscsssessccessessessesnesecsesnessesecsnsesecsessseseseeoneseesecensesessenseeeseee 147 Standardi 2 of 5 Stitchindaesu oculos tera GY CF EROR ESRB VR EE DN RNC RA OYN FYR OFF HC RHODE NL CY YDY RD 148 YTT CHAR To ES YCH HYNY FFF tme RF HAF RY FFF HERE PPP Ra EE Ha E EFO FF FAWR FRYN E 149 Chapter 6 2D Synibologi amp S anG NANNING NAGBANGGAAN 151 2 Symliologies u AA UO NF CG wasaka FFYN Y UR FFF FY CE EF ayayay Y 151 2D Decode Time Mak uya 151 Pi pe 152 Disable Enable PDF 417 p152 Length Conttols isi etri ero nena sn 153 PDF 417 Length 1 Length 2 Programming Instructions 154 Micro PDF217 UN 155 Disable Enable Micto PD P417 amain mGA AA 155 EMG Eh COMPO YNN RH NR vo EROR FR UR AA Ho NEW NAF FFI TF dnd 156 Micro PDF 417 Length 1 Length 2 Programming InStItctions maambunan aaa Sapsspipihaashasssqasaykawsasssss 157 Datamatrbt I a 158 Disable Enable Datamatrix 158 Lengt CONTO a AA ai 159 Datamatix Length 1 Eength 2 Programming IDSEFU CEIORS siisii iiin Fo 160 OR 8i o Jo Su TYN EON EYN FFRANC RA AA AA NE Y FEW HEH FRY NYDD 161 Disable Enable QR Cod itn AA FN FY FN TT FY
5. Product Reference Guide 181 Interface Default Exceptions The factory default settings indicated in the programming sections in bold text reflect factory configuration for the RS 232 standard interface The following tables list default exceptions by interface for the remaining available interfaces IBM Interfaces IBM Interfaces include USB OEM IBM Port 9B IBM Port5B and IBM Port17 Parameter Default Setting IBM Interface Type IBM Port 9B Number of Host Transmit Buffers One Buffer Label I D Transmission Disable Suffix Characters No Suffix 182 Magellan 1100i Interface Default Exceptions Interface Default Exceptions continued RS 232 Wincor Nixdorf Parameter Default Setting Interface Type RS 232 WN Number of Host Transmit Buffers One Buffer RS 232 Parity Odd RS 232 Hardware Control CTS Flow Control UPC E Check Character Conversion Disabled UCC EAN 128 Label ID P Code 39 Label ID M Code 93 Label ID E Code 128 Label ID K Codabar Label ID N EAN 8 Label ID B EAN 13 Label ID A ISBN Label ID A Interleaved 2 of 5 Label ID T Standard 2 of 5 Label ID H MSI Plessey Label ID O UPC E Label ID C GS1 DataBar Omnidirectional Label ID E GS1 Expanded Label ID E Product Reference Guide 183 Interface Default Exceptions continued Keyboards Keyboard interfaces include USB Keyboar
6. Disable Convert to Code 39 DEFAULT Product Reference Guide 53 Interface Related Features Keyboard Wedge and USB Keyboard As a keyboard interface the scanner supports most popular PCs and IBM terminals The instal lation of the wedge is a fairly simple process that doesn t require any changes of software or hard ware All of the options in this section apply to the Key board Wedge however only some apply to USB Key board NOTE Keyboard Layout The Keyboard Layout option supports many countries For details about Keyboard Layout please refer to your operating system manual USA DEFAULT ma III III TT 5 u MA DITI 54 Magellan 1100i Interface Features Keyboard Wedge cont START END Italy Norway Portugal Spain Sweden Switzerland Japan 106 Key Hungary Czech Product Reference Guide 55 Interface Related Features Keyboard Wedge cont OGRAMMING BARCODE PR Caps Lock State Specifies the format in which the scanner sends character data PROGRAMMING BARCODES Disable Caps Lock DEFAULT 56 Magellan 1100i Interface Features Keyboard Wedge cont Power On Simulation 7 This feature does not apply to the USB Keyboard interface NOTE All PCs check the keyboard status during the power on Selftest
7. Product Reference Guide 3 Getting Started LED and Beeper Indicators The scanner s beeper sounds and its green LED illuminates to indicate various functions or errors on the scanner The tables below list these indications One exception to the behaviors listed in the tables is that the scanner s functions are programmable and may or may not be turned on For example certain indications such as the power up beep can be disabled using programming barcode labels Green LED Indications LED INDICATION INDICATION COMMENT Power on Indicates the scanner has finished all its power up tests and is AU Bright green flash indication now ready for operation baka maga Bright green flash Indicates a barcode has been read and decoded Indication Scanner Ready Constant dim green The scanner is ready for operation Constant green flash The scanner is in Sleep Mode To wake the scanner up move Sleep Mode 100mS on 1900mS off oe in front of its window or press the button atop the AG Constant green flash at 1 Hz The scanner is disabled due to receiving a disble command 100mS on 900mS off from the POS terminal Varies see Error Codes on The LED can provide diagnostic feedback if the scanner dis Diagnostics page 1 5 for more information covers a problem during SelfTest Prog Mode See Host Disable above The scanner is in Programming Mode BEEPER FUNCTIONS
8. AIM ID This function is used to identify and display the common label identifier for its symbology When enabled this ID code will be transmitted before the scanned bar code data 00 20 Characters ASCII Please Keep In Mind Modifying a message string is not a mandatory requirement Data editing is sophisticated feature allowing highly customizable output for advanced users Factory default settings for data editing is typically set to NONE A prefix or suffix may be applied reference the Symbologies chapter for these settings across all symbologies set via the Global features in this chapter You can add any character from the ASCII Chart from 00 7F on the inside back cover of this manual as a prefix suffix or Label ID Enter prefixes and suffixes in the order in which you want them to appear on the output Product Reference Guide 61 Data Editing Global Prefix Suffix Up to 20 ASCII characters may be added as a prefix in a position before the barcode data and or as a suffix in a position following the barcode data as indicated in Figure 4 2 Figure 4 2 Prefix and Suffix Positions Label ID AIM ID Bar Code Data Label ID D 00 20 Characters ASCII Ra sr AND aa OR Example Setting a Prefix In this example we ll set a prefix for all symbologies 1 Determine which ASCII character s are to be added to scanned barc
9. DEFAULT SETTING PREFIX 00 None DEFAULT SETTING SUFFIX 0D CR Product Reference Guide 63 Data Editing AIMID AIM Automatic Identification Manufacturers label identifiers are assigned from a globally standardized list as opposed to custom label ID characters you select yourself and can be included with scanned barcode data AIM label identifiers consist of three characters as follows A close brace character ASCII followed by A code character see the table below followed by A modifier character the modifier character is symbol dependent SYMBOLOGY CHAR SYMBOLOGY CHAR UPC EAN E Code 128 EAN 128 C Code 39 A MSI Plessey M Codabar ien saa 7 T Interleaved 2 of 5 Standard 2 of 5 S Code 93 G ISBN Xa a ISBN X with a 0 modifier character Figure 4 3 AIM ID 1000000 Prefix Label uo Bar Code Data Label ID Suffix Disable AIM ID DEFAULT 64 Magellan 1100i Label ID Label ID A Label ID is used to identify a barcode symbology type See Appendix D Default Settings for a listing for common symbologies It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled This feature provides options for con figuring custom Label IDs individually per symbology If you wish to program the scanner to alwa
10. v DATALOGIC Magellan 1100i On Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide Datalogic Scanning Inc 959 Terry Street Eugene Oregon 97402 USA Telephone 541 683 5700 Fax 541 345 7140 An Unpublished Work All rights reserved No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scan ning Inc or its subsidiaries or affiliates Datalogic or Datalogic Scanning Owners of Datalogic products are hereby granted a non exclusive revocable license to reproduce and transmit this documentation for the purchaser s own internal business purposes Purchaser shall not remove or alter any proprietary notices including copyright notices contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic repre sentative Electronic versions may either be downloadable from the Datalogic website www scanning datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know via the Contact Datalogic page Disclaimer Datalogic has taken reasonable measures to provide information in this ma
11. 1100i Chapter 3 Interface Related Features At the time of this writing the reader supports the interfaces listed in Table 3 1 Select the desired interface type from the table then reference the page number given for the customizable features section associated with each interface See Table 3 2 for a description of each Keyboard Wedge interface type A through Y as listed Table 3 1 Interfaces Supported RS 232 IBM USB a Consult Table 3 2 for more information regarding keyboard interface RS 232 Standard RS 232 Wincor Nixdorf IBM 4683 Port 5B IBM 4683 Port 9B IBM 4683 Port 17 USB OEM USB Keyboard USB COM Interface types Page 3 33 3 33 3 33 3 33 3 33 3 33 3 33 3 33 Keyboard Wedge Keyboard Wedge A Keyboard Wedge B Keyboard Wedge C Keyboard Wedge D Keyboard Wedge E Keyboard Wedge F Keyboard Wedge G Keyboard Wedge H Keyboard Wedge I Keyboard Wedge J 3 34 3 34 3 34 3 34 3 34 3 34 3 34 3 34 3 34 3 34 3 34 7 The correct interface cable is included for the reader interface type you ordered NOTE Product Reference Guide 31 Interface Related Features Table 3 2 Keyboard Wedge Interface Reference I F Type PCs Supported PC XT w Alternate Key Encoding Ez AT PS 2 25 286 30 286 50 50Z 60 70 80 90 amp 95 w Alternate Key Encoding PS 2 25 and 30 w Alternate Key Encoding D PO XT w Standard Key Encoding AT PS 2 25 286 30 286 50 50Z
12. 2D Sample Symbols PDF 417 JT A12B3C Datamatrix ww 1314H17LL Maxicode Micro PDF 417 Hita BV17453 QR Code 35900G9 This is an Aztec Code Product Reference Guide 197 Composite Sample Symbols GS1 DataBar Limited Composite 17 050923 10 ABC123 a Lid iN 0 4012345 67890 GS1 DataBar Truncated Composite a dene NPA yr k I ad ia 09876543217899 198 Magellan 1100i ASCII Chart ASCII Hex ASCII Hex ASCII Hex ASCII Hex Char No Char No Char No Char No NUL 00 SP 20 40 i 60 SOH 01 21 A 41 a 61 STX 02 i 22 B 42 b 62 ETX 03 23 C 43 c 63 EOT 04 24 D 44 d 64 ENQ 05 25 E 45 e 65 ACK 06 amp 26 F 46 f 66 BEL 07 27 G 47 g 67 BS 08 28 H 48 h 68 HT 09 29 49 i 69 LF 0A 2A J 4A j 6A VT 0B 2B K 4B k 6B FF 0C i 2C L 4C 6C CR 0D 2D M 4D m 6D SO OE 2E N 4E n 6E SI OF 2F O 4F o 6F DLE 10 0 30 P 50 p 70 DC1 11 1 31 Q 51 g 71 DC2 12 2 32 R 52 r 72 DC3 13 3 33 S 53 S 73 DC4 14 4 34 T 54 t 74 NAK 15 5 35 U 55 u 75 SYN 16 6 36 V 56 V 76 ETB 17 7 37 W 57 w y CAN 18 8 38 X 58 X 78 EM 19 9 39 Y 59 y 79 SUB 1A 3A Z 5A z 7A ESC 1B 3B 5B 7B FS 1C lt 3C 5C 7C GS 1D u 3D 5D 7D RS 1E gt 3E A 5E 7E US 1F 2 3F 5F DEL 7F Australia Datalogic Scanning Pty Ltd Telephone 61 2 9870 3200 australia scanning datalogic com France and Benelux Datalogic Scanning SAS Tele
13. Beep Good l Read Tone B 0x42 Beeps if Good Read Beep is enabled Force Good I I Read Tone 0x01 Beeps regardless of beep setting Bel 0x07 Force Good Read Tone Identification a request i 0x69 Returns long response Health request h 0x68 Returns long response Status request S 0x73 Returns long response a Call Tech Support for information If one of the above commands is received the scanner will perform the steps indicated for the command Host commands for other interfaces are also available Contact Tech Support for more details Product Reference Guide 193 NOTES 194 Magellan 1100i Chapter G Sample Symbols 1D Symbol Samples 0 1234567890 UPC A 0 5 Interleaved 2 of 5 1234567890 Code 128 Code 128 EAN 13 9 780330 290951 Code 39 BC321 Codabar A13579B Code 93 123456 9 Product Reference Guide 195 1D Symbol Samples continued ode 2 0 C f5 123456 GS1 DataBar Omnidirectional 01 00123456789012 GS1 DataBar Expanded 0100123456789050 GS1 DataBar Limited 01 01 16543210987654 196 Magellan 1100i 2D Sample Symbols
14. CheckCharacter VerificatlOn usano oi u usq apa FRO E RE p UA RYN Ga FAGU TONY LO Check Chaiact t Bia ns Y testet E ICI LIE NIE A GY DYN NUES Length Control Jot TR UR FY Codabar Length 1 Length 2 Programming Instructions Quiet ZONES uei i TWR ROY LT Start Stop Character Type Start Stop Character Transmission uuu u YET EEEE LEER NEU GAAN AINA NANANA FAE Y RYN Staru Stop Character Marteg FEW FARDD CASH EAE YE IEEE FH UHR ETUR e GS GS Product Reference Guide iii codabarSttellldke cr GG GI a manua aa ansa usta HO WG RARE os ERU RUE 132 Taa OTA Doer 133 Eolo Ee E u aqasha E E E E E E T 134 Disable Enable Code 93 134 Lenothi CONO insa s b a 135 Code 93 Length 1 Length 2 Programming Instructions 136 Code 03 enregistre 137 Minimum Redds nA ITINERE MF re EA EET En EIE SER E E EIN EUNT E HERE DDU NT THAU 137 IASI PUSSY MR 138 Disable ErableMSI PIe5S8y veinte anan aaa maana SERERE ore LEER FYNO FFO ta ERE EHE 138 CheckiDIgIEVENNGALION aei eR 138 Cliecke Digit TANIM GA NGINITIAN AA NAKAKAANGAT 139 Number of Check Characters 139 Length Control 140 MSI Plessey Length 1 Length 2 Programming Instructions 141 MSI Plessey Stitehig NAU RF FNAN FRY EYN NF EW NHRWYN FEN YF FA FYFYR FFF EYFYI CN YNFEYN FC E AA FFO AT ENYD ENYN DDIN 142 Minimum Reads au 143 kiere
15. EAN Two Label Enables disables the ability of the scanner to decode EAN two label pairs EAN Two Label Type 1 Specifies label types and number of flag digits for EAN JAN two label pair 1 Options are EAN JAN13 EAN JAN13 2 flag digits each EAN JAN13 2 flag digits EAN JANS 1 flag digit EAN JAN13 EAN JANS 1 flag digit each Disable pairs PROGRAMMING BARCODES EAN Two Label Type 1 EAN JAN13 EAN JAN13 2 flag digits each DEFAULT EAN Two Label Type 1 EAN JAN13 2 flag digits EAN JAN8 1 flag digit EAN Two Label Type 1 EAN JAN13 EAN JANGB 1 flag digit each 88 Magellan 1100i EAN Two Label EAN Two Label continued EAN Two Label Type 2 Specifies label types and number of flag digits for EAN JAN two label pair 2 Options are EAN JAN13 EAN JAN13 2 flag digits each EAN JAN13 2 flag digits EAN JANS 1 flag digit EAN JAN13 EAN JANS 1 flag digit each Disable pairs PROGRAMMING BARCODES EAN Two Label Type 2 EAN JAN13 EAN JAN13 2 flag digits each DEFAULT EAN Two Label Type 2 EAN JAN13 2 flag digits EAN JAN8 1 flag digit EAN Two Label Type 2 EAN JAN13 EAN JANGB 1 flag digit each Product Reference Guide 89 Symbologies EAN Two Label continued EAN Two Label Type 3 Specifies label types and number of flag digits for EAN JAN two label pair 3 Options are e EAN JAN13 EAN JAN1
16. It is recommended that you enable this function if you are working without a keyboard installation It simulates keyboard timing and passes the keyboard status to the PC during power on PROGRAMMING BARCODES Disable Power on Simulation DEFAULT Product Reference Guide 57 Interface Related Features Control Characters Specifies how the scanner transmits ASCII control characters to the host Choices are Disable Control Characters Enable transmission of control characters to host Send characters between 00H and 1FH according to a special function key mapping table This is used to send keys that are not in the normal ASCII set a unique set is pro vided for each available scancode set Reference Appendix E Keyboard Function Key Map pings PROGRAMMING BARCODES Disable Control Characters DEFAULT Enable Transmission of Control Characters Iii x WA 58 Magellan 1100i Interface Features Keyboard Wedge cont Wedge Quiet Interval This feature does not apply to the USB Keyboard interface NOTE Quiet Interval is the amount of time to look for keyboard activity before the scanner breaks the keyboard connection in order to transmit data to the host PROGRAMMING BARCODE Selectable from 001 to 100 in 10 msec increments To configure this feature scan the START END barcode above to place the unit in Programming Mode then the Set Wedge Quiet Interval bar
17. decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding 1 Scan the START barcode 2 Scan the Fixed Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 0000 if there is only one fixed length by following the Micro PDF 417 Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START barcode 2 Scan the Variable Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the minimum length by following the Micro PDF 417 Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the maximum length by following the Micro PDF 417 Length 1 Length 2 Programming Instructions below Variable Length Decoding DEFAULT 156 Magellan 1100i 2D Symbologies Micro PDF 417 continued Micro PDF 417 Length 1 Length 2 Programming Instructions 1 Scan the START barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Alpha Numeric Pad and scan the four digits zero padded representing the length For Micro PDF 417 barcodes only the data characters are included in the length calculations NOTE Any value set higher than 366 will be considered to be 366 Scan the END b
18. t Expand UPC E to EAN 13 DEFAULT Minimum Reads This feature specifies the minimum number of consecutive times a UPC E label must be decoded before it is accepted as good read PROGRAMMING BARCODES Minimum 2 Reads DEFAULT Ml III Product Reference Guide 81 Symbologies GTIN The following options apply to the GTIN label data format Expand UPC EAN to GTIN When this feature is enabled the scanner will translate UPC EAN labels to the 14 digit GTIN format Don t Expand to GTIN DEFAULT 82 Magellan 1100i EAN 13 EAN 13 The following options apply to the EAN 13 symbology Disable Enable EAN 13 When disabled the scanner will not read EAN 13 barcodes Enable EAN 13 DEFAULT Check Digit Transmission Enable this option to transmit the check digit along with EAN 13 barcode data PROGRAMMING BARCODES Send Check Digit DEFAULT Product Reference Guide 83 Symbologies EAN 13 continued EAN 13 Flag 1 Character Enables disables transmission of an EAN JAN13 Flag character OGRAMMING BARCODE PR Transmit EAN 13 Flag 1 Char DEFAULT When enabled this feature truncates the leading three digits from labels that contain ISBN International Standard Book Number and appends an ISBN check character to the end of the label These codes are used for books and magazines Labels with ISBN code
19. 39 Interface Related Features RS 232 Interface Features cont Intercharacter Delay This delay is inserted after each data character transmitted If the transmission speed is too high the system may not be able to receive all characters You may need to adjust the delay to make the system work properly INI a antan DEFAULT mE IAEA MN A EAM UL Tem LLL LL LULA Tm MIA 40 Magellan 1100i Interface Features Intercharacter Delay cont OGRAMMING BARCODE PR Software Flow Control Disables Enables software control using XON XOFF characters PROGRAMMING BARCODE Disable Software Flow Control DEFAULT Product Reference Guide 41 Interface Related Features RS 232 Interface Features cont Host Echo When enabled this feature passes all data through the scanner to the host as it comes in This feature is used for applications where daisy chaining of RS 232 devices onto the same cable is necessary If for example one of the devices in the chain is a terminal where someone is entering data while another person is simultaneously scanning a barcode requiring transmission to the host the scanner will wait for the RS 232 channel to be quiet for a specified period of time set via RS 232 Host Echo Quiet Interval The scanner can be set to observe this delay before sending its data in order to avoid RS 232 t
20. 5 mil Depth of Field a 10096 UPC Labels Minimum Print Contrast Ratio 25 Skew Yaw E59 Pitch i65 Roll Between 0 and 360 Scanner Dimensions J C IN am 97 84mm ON 3 85 83 25mm 3 28 Product Reference Guide 175 Physical Properties Electrical Parameters Environmental Parameters Parameter Specification Dimensions Scanner only 3 3 X2 8 x9 7 PM q Scanner w Base 5 5 x2 9 33 8 Station Weight Scanner 7 0 oz Weight Base Station 6 6 oz Parameter Specification Operating Voltage Input voltage 4 5 to 14 VDC Input Current Operating idle 300mA Operating label read 400 mA Parameter Specification Mechanical Shock Multi 1 2m drops Contaminants Water and Dust IP52 Temperature Ranges Operating 32 F to 104 F 0 C to 440 C Storage 409 F to 158 F 40 C to 70 C Ambient Light Indoor 0 6000 lux Ambient Light Outdoor 0 86 100 lux Humidity 5 to 95 non condensing Beeper Speaker 70 85dBA at a distance of 3 3 1 meter Vibration Retail Office Other Parameters Parameter Specification EAS Support YES Checkpoint 176 Magellan 1100i Chapter B Cable Pinouts Standard Cable Pinouts Primary Interface Cables RS 232 1 CTS 10 Position RJ 5 RXD TXD Pir 1 Scanner End 8 VCCIN
21. 5581707 5594231 5594441 5598070 5602376 5608201 5608399 5612529 5629510 5635699 5641958 5646391 5661435 5664231 5666045 5671374 5675138 5682028 5686716 5696370 5703347 5705802 5714750 5717194 5723852 5750976 5767502 5770847 5786581 5786585 5787103 5789732 5796222 5804809 5814803 5814804 5821721 5822343 5825009 5834708 5834750 5837983 5837988 5852286 5864129 5869827 5874722 5883370 5905249 5907147 5923023 5925868 5929421 5945670 5959284 5962838 5979769 6000619 6006991 6012639 6016135 6024284 6041374 6042012 6045044 6047889 6047894 6056198 6065676 6069696 6073849 6073851 6094288 6112993 6129279 6129282 6134039 6142376 6152368 6152372 6155488 6166375 6169614 6173894 6176429 6188500 6189784 6213397 6223986 6230975 6230976 6244510 6259545 6260763 6266175 6273336 6276605 6279829 6290134 6290135 6293467 6303927 6311895 6318634 6328216 6332576 6332577 6343741 6454168 6478224 6568598 6578765 6705527 6857567 6974084 6991169 7051940 7170414 7172123 7201322 7204422 7215493 7224540 7234641 7243850 7374092 7407096 7490770 7495564 7506816 7527198 7527207 7537166 7562817 601 26 118 6 AU703547 D312631 D313590 D320011 D320012 D323492 D330707 D330708 D349109 D350127 D350735 D351149 D351150 D3
22. 60 70 80 90 amp 95 w Standard Key Encoding PS 2 25 and 30 w Standard Key Encoding BM 3xxx w 102 keyboard PS 55 5530T w 104 keyboard NEC 9801 IBM 3xxx w 122 keyboard I I Reference Appendix E Keyboard Function Key Map pings for more information about keyboards NOTE 32 Magellan 1100i Interface Selection Interface Selection PROGRAMMING BARCODES LLL mE AI MIA ian III II USB OEM MA III Product Reference Guide 33 Interface Related Features Interface Selection cont LIL nao Seger 34 Magellan 1100i Interface Features Interface Features Obey Ignore Host Commands When set to ignore host commands the scanner will ignore all host commands except for the minimum set necessary to keep the interface active and transmit labels For normal operation of the interface select Obey Host Commands PROGRAMMING BARCODES Obey Host Commands DEFAULT Product Reference Guide 35 Interface Related Features Interface Features cont Host Transmission Buffers Specifies the number of host transmission s that may be buffered By buffering data from a bar code the scanner can continue to read a new barcode while the old one is being transmitted to the host Selecting BUFFERS 1 means that the first barcode must be transmitted before a new one can be re
23. Cell Phone Detection Sensitivity HIGH Product Reference Guide 27 General Features Cell Phone Detection Sensitivity continued PROGRAMMING BARCODE Cell Phone Detection Sensitivity MEDIUM This is the DEFAULT setting Cell Phone Detection Sensitivity LOW 28 Magellan 1100i Cell Phone Mode Cell Phone in Target Mode This feature sets the reader s Cell Phone Mode when it is in Target Mode A This feature is only available when Cell Phone Mode is enabled NOTE No Cell Phone Mode Will not read cell phone labels when in Target Mode Auto Detection Cell Phone Mode Automatically detects cell phone labels and shifts to Cell Phone Mode when in Target Mode Always Enter Cell Phone Mode The reader will always enter Cell Phone Mode whenever it is in Target Mode Follow these instructions to configure this feature 1 Determine which mode is desired from the selections above 2 Scan the START barcode to place the scanner in Programming Mode 3 Scan the two barcodes which configure the desired mode 4 Scan the END barcode PROGRAMMING BARCODE Cell Phone in Target Mode No Cell Phone Mode This is the DEFAULT setting Product Reference Guide 29 General Features Cell Phone in Target Mode continued PROGRAMMING BARCODE Cell Phone in Target Mode Auto Detection Cell Phone Mode Cell Phone in Target Mode Always Enter Cell Phone Mode 30 Magellan
24. Enable Beep on Not On File DEFAULT 46 Magellan 1100i Interface Features ACK NAK Options This enables disables the ability of the scanner to support the RS 232 ACK NAK protocol When configured the scanner and or host sends an ACK when it receives data properly and sends NAK when the data is in error Selections for this option are Disable Enable for label transmission the scanner expects an ACK NAK response from the host when a label is sent Enable for host command acknowledge the scanner will respond with ACK NAK when the host sends a command Enable for label transmission and host command acknowledge Disable ACK NAK DEFAULT Enable ACK NAK for transmission and host command I Product Reference Guide 47 Interface Related Features RS 232 Interface Features cont cont ACK Character MMING BARCODE Sets the ACK character from the set of ASCII characters or any decimal value from 000 to 255 Pad entries of less than three digits with zeros as in 005 To configure this feature scan the START END barcode above to place the unit in Programming Mode then the Set ACK Character followed by the digits from the Alphanumeric table in Appendix C Alpha Numeric Pad representing your desired character Exit programming mode by again scanning the START END barcode above DEFAULT SETTING FOR THIS FEATU
25. Guide 23 General Features Image Compression Specifies the starting image compression factor for JPEG images A higher number specifies a higher quality image with less compression than a relative lower number for the same image A value of 100 means minimal compression A value of 1 means maximum compression at a loss of quality Follow these steps to program this feature 1 Scan the START barcode 2 Scan the Set Image Compression barcode 3 Turn to Alpha Numeric Pad and scan the two digits zero padded representing the desired compression The configurable range is 01 0x64 by increments of 01 Scan the END barcode OGRAMMING BARCODE PR Set Image Compression DEFAULT SETTING IS 100 minimal compression higher quality Image Size Specifies the size of the image capture Choices are WVGA VGA OGRAMMING BARCODE PR Image Size WVGA DEFAULT 24 Magellan 1100i Image Capture Image Brightness This feature sets the image brightness value Follow these instructions to configure this feature 1 Scan the START barcode 2 Scan the Set Image Brightness barcode 3 Turn to Alpha Numeric Pad and scan the two digits zero padded representing the desired brightness in decimal notation The configurable range is 01 0x0A by increments of 01 4 Scan the END barcode PROGRAMMING BARCODES Set Image Brightness DEFAULT SETTING FOR THIS FEATURE 09 Image Contra
26. Product Reference Guide 115 Symbologies Code 128 The following options apply to the Code 128 symbology Disable Enable Code 128 When this feature is disabled the scanner will not read Code 128 barcodes START END PROGRAMMING BARCODES Enable Code 128 DEFAULT Disable Enable EAN 128 When this feature is disabled the scanner will not read EAN 128 barcodes Enable EAN 128 DEFAULT 116 Magellan 1100i Code 128 Code 128 continued Transmit Function Characters Enables disables transmission of Codel28 function characters 1 2 3 and 4 Function codes are transmitted as follows FNCI 80 hex FNC2 81 hex FNC3 82 hex FNC4 83 hex Don t Transmit Function Characters DEFAULT Product Reference Guide 117 Symbologies Code 128 continued Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding 1 Scan the START barcode 2 Scan the Fixed Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the first fixed length by follow
27. Sonme SRN Code 39 Stitching ad Las TR MR ate a DE C E E Code 32 Italian Pharmaeode uuu y y cech acc tat d t Er er E RH Quan asss usa asawa e ERR Ee dd Disable Enable Code 32 ItaliatrPlhi tmatode uacua re t Hate est SRG EL YNYD AA CN NU GYMAR ROS Starv step Charact Elsie re E Code 32 Italian Pharmacode continued Check Character Transmit Code 128 AA m Disable Enable Code 128 u uuu titre rc pec E CEPR ER RICE ROSE E aaa DERE DU WR FF Disable Enable EAN 128 uu ccsssscssssssessssssesssessssssesssessscssssssesssessscsssssecsscssssssssssessnessssssssssssssesssessesssesssesssssuessscesssssesasessscesecesesaseesscesecsseeaneeaseeseesseess Tibial fa SEMPER LUNN CEDE 6 a Fel D YH REFER FRI UF Naan tome tire FN FN DF FFF FFF FON Length Ganto seen gawn E Code 128 Length 1 Length 2 Programming Instructions Code 128 Conversion to Code 39 Code 128 Stitching s Minimum AA intedeaved ON SESS Disable Enable Interleaved 2015 32 IDAD IDADAAN NAGIGING NN BANGAG ANAKAN NANANA Check Digite al cil AEN Naa BABABA Y masan MAAN NANA AA NC AGO el BI a asus ez HUE ROO FFO Y UC OF Lengt CORTO oo actae qaaa eb RH aa eR RW o MU FRYN FR EU base RHY FT HEFYD Y HY RT ass anun Interleaved 2 of 5 Length 1 Length 2 Programming Instructions k te Gea VSG 2015 SUECHIDBD aen RAO E DD GC CO ORRA Miripunhedds aa A E E N MI NUI MM LEE Codaban GG WG GO GNU yT GAU GG Sanm LABANAN UF GC 20 Disable EnableGodadbialp sandstone BA AA FYNY FFYRDD Naan
28. enables disables the green spot activation when good read is activated PROGRAMMING BARCODES Disable DEFAULT Green Spot Magellan 1100i LED and Beeper Indicators Aiming Pointer Settings Enabes disables Aiming Pointer for all symbologies PROGRAMMING BARCODES Disable DEFAULT Product Reference Guide 19 General Features Scanning Features Targeted Scanning Mode Upon pressing the button the scanner will project an aiming pattern to assist in centering over the barcode Scanning then takes place as soon as the button is released When add ons are enabled and a barcode is being read while in Targeted Mode position the pointer at or near the end of the base label to ensure the scanner will read both the base and add on label NOTE Targeted Scanning Mode will read barcodes in any orientation The scanner will return to full pattern Omni direc tional Mode after Target Mode Active Time has elapsed Configuration options for Targeted Scanning Mode are Target Mode Active Time Target Mode Linger Time Target Mode Active Time Specifies the time duration the scanner attempts to decode labels while in the targeted mode of operation m II II u kai DLL DEFAULT III min 20 Magellan 1100i Scanning Features Target Mode Linger Time Specifies the time duration the scanner remains in the targeted m
29. minimum length by following the Datamatrix Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the maximum length by following the Datamatrix Length 1 Length 2 Pro gramming Instructions below Variable Length Decoding DEFAULT Product Reference Guide 159 2D Symbologies Datamatrix continued Datamatrix Length 1 Length 2 Programming Instructions 1 Scan the START barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Alpha Numeric Pad and scan the four digits zero padded representing the length For Datamatrix barcodes only the data characters are included in the length calculations NOTE Any value set higher than 800 will be considered to be 800 Scan the END barcode Set Length 1 DEFAULT SETTING FOR THIS FEATURE 0800 ULT SETTING FOR THIS FEATURE Set Length 2 160 Magellan 1100i 2D Symbologies QR Code Disable Enable QR Code When disabled the scanner will not read QR Code labels START END PROGRAMMING BARCODES Disable QR Code DEFAULT Enable QR Code Product Reference Guide 161 2D Symbologies QR Code continued Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a barcode if the label length matches o
30. 0 for character three and 00 for the control character 00 indicates no character 6 Scan the END barcode to exit programming mode Figure 4 4 Label ID Position Options 200000 Prefix Label ID Aim ID Bar Code Data Label ID Suffix bi at om wm um Product Reference Guide 65 Data Editing Label ID cont START END Label ID Position Before Barcode Data DEFAULT Label ID Transmission Disable Label ID Position After Barcode Data Set UPC A Label ID Character s DEFAULT SETTING FOR THIS FEATURE A 41 hex Set UPC A w P5 Addon Label ID Character s FAULT SETTING FOR THIS FEATURE A 41 hex Set UPC A w P2 Addon Label ID Character s EFAULT SETTING FOR THIS FEATURE A 41 hex DEFAULT SETTING FOR THIS FEATURE A 41 hex Set UPC A w C128 Addon Label ID Character s Set UPC E Label ID Character s AULT SETTING FOR THIS FEATURE E 45 66 Magellan 1100i Label ID Label ID cont PROGRAMMING BARCODES DEFAULT SETTING FOR THIS FEATURE E 45 hex Set UPC E w P2 Addon Label ID Character s ING F DEFAULT SETTING FOR THIS
31. 0 Sleep Mod 11 Haei aek A aa EEN eA E NR GG ai 13 Power On Alert ERI Active State High ERI THMIMOOUT as iy Good Read When to Indicate aasa FYTH FNYFNFL NY FFNRFIF FA YT NON S Good Read BeeprContiollane ue YRU GC FT EC FFO DYSG YO FC Y NANG GocdiReacd Beep Freduien AA Good Read Beep Lei d EE EET EE TOO DOTT Good ReadiBeep Volume e Green SPOOL a assess sys M Aiming Pointer Settings Scanning Features Targeted Scanning Mode Target Mode Active TIME aman GG AUAN HU Ge eR Roe CH YDAN NFED GORF NA AG FFO GOFFA MUDO ER ALI ANNA Target Mode linger Tim ur SF do Wake Upilntensity use iY HE EEEE E FUE UT AO CYF Y WD YY GORFU limage Gea US e T How to Capture an Image Image Compression Image Size Ithage Brighthess mue Gn E ipe sayasqa saq ei e GU ERN DS Image Contrast amak tni qued dte HER pe c AME E cepe ce EO ee FUE AABANGAN NG cell Phone lolo EEE m AA iiasssa sessssesse Cell Phone Mode Enable e EN Cell Phone Detection Sensitivity Cell Phone im Target Mode un ie iii dI ERYN Chapter 3 Interface Related Features Aa EBLOTI ood ma du hat IIT LI CHI UE LM pu 33 Interface Features ecrit tet FEE TY YY FFF FE
32. 3 2 flag digits each EAN JAN13 2 flag digits EAN JAN68 1 flag digit EAN JAN13 EAN JANS8 1 flag digit each Disable pairs PROGRAMMING BARCODES EAN Two Label Type 3 EAN JAN13 EAN JAN13 2 flag digits each DEFAULT EAN Two Label Type 3 EAN JAN13 2 flag digits EAN JAN8 1 flag digit EAN Two Label Type 3 EAN JAN13 EAN JAN8 1 flag digit each 90 Magellan 1100i EAN Two Label EAN Two Label continued EAN Two Label Type 4 Specifies label types and number of flag digits for EAN JAN two label pair 4 Options are EAN JAN13 EAN JAN13 2 flag digits each EAN JAN13 2 flag digits EAN JANS 1 flag digit EAN JAN13 EAN JANS 1 flag digit each Disable pairs EAN Two Label Type 4 EAN JAN13 EAN JAN13 2 flag digits each EAN Two Label Type 4 EAN JAN13 2 flag digits EAN JAN8 1 flag digit EAN Two Label Type 4 EAN JAN13 EAN JANG 1 flag digit each DEFAULT Product Reference Guide 91 Symbologies EAN Two Label continued EAN Two Label Combined Transmission Enables disables the transmitting of an EAN two label pair as one label DEFAULT EAN Two Label Combined Transmission Enable III IWAN EAN Two Label Combined Transmission Disable 92 Magellan 1100i EAN Two Label Combined Transmission EAN Two Label continued EAN Two Label Minimum Reads This feature specifie
33. 52936 D352937 D352938 D352939 D358588 D361565 D372234 D374630 D374869 D375493 D376357 D377345 D377346 D377347 D377348 D388075 D446524 EPO256296 EP0260155 EPO260156 EP0295936 EPO325469 EPO349770 EP0368254 EP0442215 EP0498366 EP0531645 EP0663643 EP0698251 EPO1330772 GB2252333 GB2284086 GB2301691 GB2304954 GB2307093 GB2308267 GB2308678 GB2319103 GB2333163 GB2343079 GB2344486 GB2345568 GB2354340 ISR107546 ISR118507 ISR118508 JP1962823 JP1971216 JP2513442 JP2732459 JP2829331 JP2953593 JP2964278 MEX185552 MEX187245 RE37166 RE40071 Other Patents Pending Table of Contents Chapter 1 Getting Started About This Manual Manuall onventio ns ee A FYFYRWYR casa YE FY GC FRAU 1 Connecting te Scann eT uii Gi cs AA q E 2 Ketele laalaa Tare AA E AE 3 Using the Programming BalCOGCles eiu ciclo ctii GAAN q qupa ODYNO A UY 3 Resetting the Standard Product Defaults LED and Beeper Indicators Eror GOES M 5 Chapter 2 General FeatUlBs ssssssssissssssssssicossnsisussiscasanssessousvausssnoassannesssassnssvansiasssnnadsnsnesesisesassonseshosussdsusdcsnsusedpsnsbssabessatessnseansnennsagd 7 Double Read Timeout for Linear Labels Double Read Timeout for 2D Labels an9 LabelGone Timeout e nni aa AA E RAN 10 Productivityihdex Reporting BIR paanan OF idd GATE NANANA YA FO RE ODD eteina 1
34. 9 GND 10 IBM Port 5B 9B 17 1 10 Position RJ 5 DATA Scanner End 8 VCC IN 9 GND 10 Product Reference Guide 177 Cable Pinouts USB OEM 1 10 Position RJ p 5 D Pin 1 Scanner End 8 VIN 9 GND 10 USB USB Keyboard amp USB COM 1 10 Position RJ mmm 5 D Scanner End 8 VBUS VIN 9 GND 10 Keyboard Wedge 1 2 KB DATA ika 3 AT CLK 10 Position RJ 5 AT DATA Pin 1 Scanner End 8 VCC IN 9 GND 10 178 Magellan 1100i Chapter C Alpha Numeric Pad LLLI A III B MIMO C IU D MIN E F Product Reference Guide 179 Alpha Numeric Pad 1 3 5 7 9 2 4 6 8 0 180 Magellan 1100i Appendix D Default Settings Defaults by Symbology The following is a partial list of key settings for each symbology type Code Type HAU kaba Kana Label emani Enable Enable b UPC A v 4 4 A UPC E EAN 13 4 4 4 F EAN 8 v y 4 FF GS1 DataBar Omnidirectional R4 GS1 Expanded RX Code 39 v 4 PharmaCode 39 A Code 128 v Interleaved 2 of 5 4 i Codabar 4 Code 93 amp MSI Plessey 4 Standard 2 of 5 v S PDF 417 P Micro PDF 417 mP Datamatrix Dm QR Code QR Maxicode MC Aztec Az GS1 DataBar Omnidirectional 2D Composite R4 GS1 DataBar Expanded 2D Composite RX GS1 DataBar Limited 2D Composite RL
35. ARN ARE FFF t a FE FYN sisse PE ce eH ERE HR LLLA En edu HWNNW 35 Obey Ignore Host Command S sssini u apana YSARGAU FANA cq ADUR DAY AREE FERRARI E AAAS 35 Host hransmissionib felis iste senti RF RT I NW FD HN D DL UND TEC 36 RS 232 interface ECAC ULES u u u Dr ERE REI Ute egi HE Da eR cu ISO Gn CLE DU tip Lem sa 37 Pary NAH PAGPAG KA u u ga nmana TY YY asna EU SG NU SH NT 39 Interchatacter Del FU 40 Software FOW COMOL nenu GR S I Cau RE i A Fu A NG y CAE 41 Host Et y Ec 42 ble st Eh VCs DUN UCI OE aln cesta a T TYN AA AG 43 Signal Voltage Normal A eo 44 PS 2S PA BD VBRE HR ew AEE NF FY ANA 45 Product Reference Guide i Been ASGIIIBEE sanos dide REDE EU aman inu DFTN AD aaa AO WD GUIR Beep on Noton File sees Gu IR ARA ANN NANANA ABA NANANA NAAN ANAN AA ACKNAKOptionS ine GR OG FWY AYRA COED NGARDD CERYS FAND ACK Character NAK Character Retry on ACK NAK Timeout ACICNAK Tirso Ut Values uic ceste IO RHUF e YO RO AGKNAKRetry Count iia ssbdubassaysassenosazevacbeadatu FEED SS ACKINAK Error blandlingiussei ii y YNAT NAN FFY TYRRU RW UE ANAN CH CO Lena Fd oL All CAE o Les y o YNDE AH WPD NR FFY FRYN WYR RAT WYF FARF TOR UU RYE ERECTO OTE USB OEN Interface Features ei u nunus aa uama DANGAN NAN NAN NG NANANG ANAN USB OEM DEVICE USAGE au au Ga DYFI KANG RA NANANA ENOC a E TAU IBM Transmit Labels in Code 39 Format Keyboard Wedg
36. BEEPER INDICATION INDICATION COMMENT The Power On LED indication is a configurable feature which Power On Bee Sinal bae can be enabled or disabled When enabled this beep Indi P 9 p cates the scanner has finished all its power up tests and is now ready for operation Good Baad The good read beep indication is configurable Options Indic fion Single beep include Enable disable frequency duration and volume See the Product Reference Guide PRG for more information I Varies see Error Codes on The Beeper can provide diagnostic feedback if the scanner Diagnostics page 1 5 for more information discovers a problem during SelfTest S Varies depending upon the fea The Beeper will sound as programming barcode labels are WW ture s being configured scanned indicating progress during scanner configuration Indications 4 Magellan 1100i Error Codes Error Codes Upon startup if the scanner flashes its indicator LED or sounds an unexpected series of beep tones other than normal power up indications this means the scanner has not passed its auto matic Selftest and has entered FRU isolation mode If the scanner is reset or the trigger is pulled the sequence will be repeated The following table describes the LED flashes beep codes associated with an error found NUMBER OF LED FLASHES ERROR CORRECTIVE ACTION BEEPS 1 Configuration 2 Interface PCB 6 Main PCB 10 Button Error Contact Helpdesk for
37. Bh 1Ah SUB F5 6Ch 1Bh ESC ESC 3Dh 1Ch FS F7 6Eh 1Dh GS F8 6Fh 1Eh RS F9 70h 1Fh US F10 71h 190 Magellan 1100i Keyboard Model Cross Reference Table E 8 NEC 9801 Key Function Key Map ASCII value ASCII code Key Scancode 00h NUL unused n a 01h SOH CR 1Ch 02h SIX CAPS LOCK ON make 71h 03h ETX CAPS LOCK OFF break Fih 04h EOT CTRL left Make 74h 05h ENQ CTRL left Break F4h 06h ACK CTRL C 60h 07h BEL n a n a 08h BS BS QEh 09h HT TAB right OFh OAh LF RIGHT arrow inner keypad 3Ch 0Bh VT TAB left OFh S 0Ch FF DELETE 39h 0Dh CR CR 1Ch 0Eh SO INSERT inner keypad 38h OFh SI KATAKANA LOCK ON Make 72h 10h DLE KATAKANA LOCK OFF Break F2h 1th DC1 HOME inner keypad 3Eh 12h DC2 LEFT arrow inner keypad 3Bh 13h DC3 DOWN arrow inner keypad 3Dh 14h DC4 UP arrow inner keypad 3Ah 15h NAK F6 67h 16h SYN F1 62h 17h ETB F2 63h 18h CAN F3 64h 19h EM F4 65h 1Ah SUB F5 66h 1Bh ESC ESC 00h 1Ch FS F7 68h 1Dh GS F8 69h 1Eh RS F9 6Ah 1Fh US F10 6Bh Product Reference Guide 191 NOTES 192 Magellan 1100i Chapter F Host Commands OM Accepting RS 232 Commands The scanner responds to the following RS 232 commands COMMAND ASCII HEX COMMENT Enable Scanner E 0x45 Disable D 0x44 Scanner Reset Scanner R 0x52 Not On File F 0x46 Long series of beeps
38. Check Digit Verification When enabled the scanner will verify the check digit of the labels ROGRAMMING BARCODE pI EOE M Disable Check Digit Verification DEFAULT 144 Magellan 1100i Standard 2 of 5 Standard 2 of 5 continued Check Digit Transmit When this option is enabled the scanner will transmit the check digit Enable Check Digit Transmission DEFAULT Product Reference Guide 145 Symbologies Standard 2 of 5 continued Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding L 2 3 4 Scan the START END barcode Scan the Fixed Length Decoding barcode Scan the START END barcode Set Length 1 to the first fixed length by following the Standard 2 of 5 Length 1 Length 2 Programming Instructions below Set Length 2 to the second fixed length or to 00 if there is only one fixed length by fol lowing the Standard 2 of 5 Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding lu 2 3 4 Scan the START END barcode Scan the Variable Length Decod
39. D Symbologies Disable Enable GS1 DataBar Limited 2D Component When enabled if a GS1 DataBar Limited label is decoded which has the 2D linkage flag set the 2D component must also be decoded or the base label will be discarded When disabled only the GS1 DataBar Limited base label will be decoded and transmitted regardless of the state of the linkage flag PROGRAMMING BARCODES Disable GS1 DataBar Limited 2D Component DEFAULT Enable GS1 DataBar Limited 2D Component ll III Product Reference Guide 171 2D Symbologies NOTES 172 Magellan 1100i Advanced Decoding Features Pharmacy Patterns Enables disables using the pharmacy patterns PROGRAMMING BARCODES Pharmacy Patterns Disable DEFAULT Product Reference Guide 173 Advanced Decoding Features Inverse Label Reading This controls the method of reading inverse labels white label on black background This feature is only available for GS1 DataBar and 2D symbologies NOTE 2D Read Mode Reads only normal labels DEFAULT 2D Read Mode Reads both normal and inverse labels WI III 174 Magellan 1100i Chapter A Product Specifications CA Optical and Read Performance Parameters Parameter Specification Scan Volume 70 cubic inches Scan Pattern 136 Scan Lines Scan Rate 1 768 scan lines second Minimum Resolution
40. EWN FWY HYR EE ET EEES AA FED MRON FAU 80 Expand to UPGEt0UPG AN Wr FU UCD TY Y asta TF RF 80 Expand UPC E to EAN13 81 Minimum Reads 81 GTIN ua asawa 82 Expand UPC EANIGGTIN NTYiuu ANNA BANANA ANAN cedes o RR ANGKAN ete aaa Renee 82 EA act ERR HER RENE ND RUMQUE AN 83 Disable Enabl amp EANl 3 ni 83 Check Dig TINA sm S BIOFY aan A HF EE EEEE E YF DYU RYNG 83 EAN 13 Flag 1 Character 84 ISBN ninas 84 Minimum Reads 85 EANG u BA NAN HN ANA NANANA NANANA GAD M 86 Disable Enable EAN 8 MER TB HR HT TR RAF TY NN YAR DYF NAF NT 86 Check Digit Transnnis5iOl ien ii eieaa YAR ALAF FERRY O FARC RW YNA UAD FFY REM eR RR S conn 86 NEL Beats auccm HB Y E OE AO WUY FR oa ea A A UU 87 EAN Two Label 88 EAN Two Label Type 1 EAN Two Label Type 2 ma BI EAN AO Label TYPE S aaa aia AEE Y AA AN Gr ARS RID erri a Rd i AE 90 EAN Two Label Type 4 nisal GO ESTRENO ERE OUR VERRE TRU ee REOR DN DER SERRE SR GUY 91 EAN Two Label Combined TransmissiOD scc awana Ea de Torre iS EE Nc SEEE Ni e Ra 92 EAN FwasLabel Minnie ds maa DEEP Nanaman ABAKA ANAN P Eu REO a AA AA AN 93 Magellan 1100i Price eig Check DIGIE uuu mido sass NE YNTE OAOD DO DOG M ANM 94 Add ons DAD IGE Addoris Mi im umiReadsu conati tete NAKUNAN NANA FU D ira dU ERA PU bp FL Una FRE BEER 97 S Digit Ada Oms Minimum Read rtu ai FOTY IE
41. FEATURE E 45 hex Set UPC E w P5 Addon Label ID Character s DEFAULT SETTING FOR THIS FEATURE E 45 hex Set UPC E w C128 Addon Label ID Character s DEFAULT SETTING FOR THIS FEATURE FF 4646 hex Set EAN 8 Label ID Character s DEFAULT SETTING FOR THIS FEATURE FF 4646 hex Set EAN 8 w P2 Addon Label ID Character s DEFAULT SETTING FOR THIS FEATURE FF 4646 hex Set EAN 8 w P5 Addon Label ID Character s DEFAULT SETTING FOR THIS FEATURE FF 4646 hex Set EAN 8 w C128 Addon Label ID Character s DEFAULT SETTING FOR THIS FEATURE F 46 hex Set EAN 13 Label ID Character s Product Reference Guide 67 Data Editing Label ID cont START END FAULT SETTING FOR THIS FEATURE F 46 hex Set EAN 13 w P2 Addon Label ID Character s Set EAN 13 w P5 Addon Label ID Character s FAULT SETTING FOR THIS FEATURE F 46
42. FYR NF EFFRO EUREN EAE RE HEY EH e REI 161 Length Control sei YD Y UR OU OFO UO AA NUDD O 162 OR Code Length 1 Length 2 Programming Instructions 163 Maxicode uu uu gyda 164 Disable Enable Maxicode 164 Length Control maa NAA GN YD YR WYF FU FD FC GNU FN GU i 165 Maxicode Length 1 Length 2 Programming Instructions II u u 166 y A FE ANA Pisable Enabl A ZC e ER Length onto iet ra et e aye Aztec Length 1 Length 2 Programming Instructions Composite Labels un un GY Y Disable Enable GS1 DataBar Omnidirectional 2D Component u 170 Disable Enable GS1 DataBar Expanded 2D Com poet mkaka 170 Disable EriableGST DataBar Limited 2D Component ccccazsssesssssscadssssssza ssascacessssssnssccuousssabassszcssscosusnassedsccascortvesnnpsaseeauaceeuaaatoneceass 171 Chapter 7 Advanced Decoding Features ssssssecsssssssessssssessessesssssesesessesessssesesessesesesessesesessesesessesesessssesessesesesessesesesseseses 173 Pharmacy Pat OTIS ministeria He RA a u s y t FUR BABANGGA ANAN 173 mwverseEabeliReagingu l l Su HU R GY Y Gy OD Y CCG Od 174 iv Magellan 1100i Appendix A Product Specifications Vy i Opticaliand Read Performiarnce Parameters uu times enai a OO 175 Seanner DIMENSIONS Lama ANI NAGA TNA NAKAANGAT oasessscesteTosnssdhastosuibuslatsavsideb
43. For 220 230 VAC To Host Terminal a adapters the ME cord must be facing down as RN shown in the N umm Seton If installed upwards A C Adapter it will pose an if needed undue strain on the socket outlet USB Connection Connect the scanner to a USB port on the terminal PC using the correct USB cable for the interface type you ordered Reference Figure 1 and Figure 2 USB installations may require a power connection via an approved A C Adapter as shown in Figure 1 For example this would be the case if the scanner is con nected along with a number of other devices to a non NOTE powered USB hub Figure 2 Other Connection Types Magellan 1100i Programming IBM Connection Connect the scanner to the IBM port on the terminal PC using the cor rect IBM cable Reference Figure 2 Keyboard Wedge Connection Before connection turn off power to the terminal PC The Keyboard Wedge cable has a Y connection from the scanner Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal PC Reference Figure 2 Programming The scanner is typically factory configured with a set of default features standard to the interface type you ordered After scanning the interface barcode from the Interface Related Features sec tion you can select other options and customize your scanner through use of the instructio
44. For Aztec labels only the data characters are included in the length cal culations NOTE Any value set higher than 3700 will be considered to be 2710 Scan the END barcode Set Length 1 DEFAULT SETTING FOR THIS FEATURE 2710 DEFAULT SETTING FOR THIS FEATURE 0001 Set Length 2 Product Reference Guide 169 2D Symbologies Composite Labels Disable Enable GS1 DataBar Omnidirectional 2D Component When enabled if a GS1 DataBar Omnidirectional label is decoded which has the 2D linkage flag set the 2D component must also be decoded or the base label will be discarded When disabled only the GS1 DataBar Omnidirectional base label will be decoded and trans mitted regardless of the state of the linkage flag PROGRAMMING BARCODES Disable GS1 DataBar Omnidirectional 2D Component DEFAULT Enable GS1 DataBar Omnidirectional 2D Component MI MI Disable Enable GS1 DataBar Expanded 2D Component When enabled if a GS1 DataBar Expanded label is decoded which has the 2D linkage flag set the 2D component must also be decoded or the base label will be discarded When disabled only the GS1 DataBar Expanded base label will be decoded and transmitted regardless of the state of the linkage flag Disable GS1 DataBar Expanded 2D Component DEFAULT 170 Magellan 1100i 2
45. R Eel repris ens HEU 98 GS1 DataBar Omnidirectional Stacked Omnidirectional sssssssssssssssscsscsscssosssssssssssssssussassnscoscovesssssssnssasscssoscoscoseosconsssusateausassuesanecsees 99 Disable Enable GS1 DataBar Omnidirectional sssssssssssssssssesssessecssesssesssessscssesssesssessscssesssessssssesssesssesssssasssesssessscssessscsasesscesseesneeaseeseesseess 99 UCC EAN T28 EImitllatioFi sse ua ciet sena oce UR S Coe En cust DUE RR cM S A EO ERE 99 MIMU aq aan pa xD LIU MM M EC MIA MMC 100 DataBar Expanded Expanded Stacked uuu yu y teat rte ORE RR RUBER EE Y CC CEFN KEEN 101 Disable Enalole GS1DataBanpEXpaudeu iniecit ee RWYF UYN FFO Rr E RAP ELE Ene prre SR Pr EE 101 GS1 128 Em Ul A OM uya qa ayna aD rir tris Abr FR EE FR SHE TU YO Cute HER RE UNE CoL FERME UT EFI REPERI 101 PETG kA EHO AA 102 GS1 DataBar Expanded Length 1 Length 2 Programming Instructions 103 AA Tse S BY uro nave HN FN Coupon Read Control a Datta LImited NR Disable Enable GST4DataBarEIiltecd ccu rire eset tiat anias ase aamin aNG ee ama GS1 128 EMUlALON cm citt tete EH SEO GR SLT CE I NG ANON E ta tren bn D Locis ED DC RR EUER MINIMUMRA HON FY RR NU Ce s Code 39 sou quqasas Disable Enable Code 39 Check Character Calculation ie Check Character Trash YE EC GANANG WN RH HRN YNI a YN NG AANO Start Stop e Code Full SOM ocio dra utate redire Edi nt pmi n into AA Length Conti ol AAAH AA Code 39 Length 1 Length 2 Programming Instructions Quiet ZoNe
46. RE 006 Set ACK Character NAK Character PROGRAMMING BARCODE Sets the NAK character from the set of ASCII characters or any decimal value from 000 to 255 Pad entries of less than three digits with zeros as in 005 To configure this feature scan the START END barcode above to place the unit in Programming Mode then the Set NAK Character followed by the digits from the Alphanumeric table in Appendix C Alpha Numeric Pad representing your desired character Exit programming mode by again scanning the START END barcode above DEFAULT SETTING FOR THIS FEATURE 021 Set NAK Character 48 Magellan 1100i Interface Features RS 232 Interface Features cont Retry on ACK NAK Timeout Enables disables retry after the configurable ACK NAK Timeout Value set in the following fea ture has expired OGRAMMING BARCODE PR Enable Retry on ACK NAK Timeout DEFAULT ACK NAK Timeout Value PROGRAMMING BARCODE This item specifies the time the scanner will wait for an ACK character from the host following a label transmission 000 Infinite timeout 001 075 Timeout in 200 millisecond increments To configure this feature scan the START END barcode above to place the unit in Programming Mode then the Set ACK NAK Timeout Value followed by the three digits zero padded from the Alphanumeric table in Appendix C Alpha Numeri
47. S F9 Oth 1F US F10 09h Table E 5 Scanset 3 102 Key Function Key Map ASCII hex ASCII code Key Scancode 00 NUL ALT right Make 89h 01 SOH ALT right Break FOh 39h 02 STX ALT left Make 19h 03 ETX ALT left Break FOh 19h 04 EOT CTRL left Make 11h 05 ENQ CTRL left Break FOh 11h 06 ACK CTRL right Make 58h 07 BEL CTRL right Break FOh 58h 08 BS BS 66h 09 HT TAB right ODh 0A LF RIGHT arrow inner keypad 6Ah 0B VT TAB left ODh S 0C FF Enter inner keypad 79h 0D CR CR bAh 0E SO INSERT inner keypad 67h OF SI PAGE UP inner keypad 6Fh 10 DLE PAGE DOWN inner keypad 6Dh 11 DC1 HOME inner keypad 6Eh 12 DC2 LEFT arrow inner keypad 61h 13 DC3 DOWN arrow inner keypad 60h 14 DC4 UP arrow inner keypad 63h 15 NAK F6 2Fh 16 SYN FA 07h 17 ETB F2 OFh 18 CAN F3 17h 19 EM F4 1Fh 1A SUB F5 27h 1B ESC ESC 08h 1C FS F7 87h 1D GS F8 BFh 1E RS F9 47h 1F US F10 4Fh 188 Magellan 1100i Keyboard Model Cross Reference Table E 6 Scanset 3 122 Key Function Key Map ASCII hex ASCII code Key Scancode 00 NUL X ALT Right Make 89h 01 SOH ALT Right Break FOh 39h 02 STX ALT left Make 19h 03 ETX ALT left Break FOh 19h 04 EOT CTRL left RESET Make only 11h 05 ENQ CTRL left RESET Make Break 11h FOh 11h 06 ACK ONLINE Enter Make only 58h 07 BEL ONLINE Enter Make Break 58h FOh 58h 08 BS BS 66h 09 HT TAB ri
48. ULT Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as a good read Minimum 1 Read DEFAULT NN II AI Product Reference Guide 137 Symbologies MSI Plessey The following options apply to the MSI Plessey symbology Disable Enable MSI Plessey When this feature is disabled the scanner will not read MSI Plessey barcodes Disable MSI Plessey DEFAULT Check Digit Verification This feature specifies whether one or two check digits are to be calculated and verified Disable Check Digit Verification DEFAULT 138 Magellan 1100i MSI Plessey MSI Plessey continued Check Digit Transmit When this option is enabled the scanner will transmit one digit or two digit check digits depending upon the setting for check digit verification Enable Check Digit Transmission DEFAULT Number of Check Characters Specifies number of MSI Plessey check characters to be calculated and verified ROGRAMMING BARCODE P 1 Check Character DEFAULT Product Reference Guide 139 Symbologies MSI Plessey continued Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length De
49. ad A selection of BUFFERS 2 means that a new barcode can be read while data from the first barcode is transmitted When a DISABLE SCANNER command is received from the host the scanner will continue to transmit all data that is buffered PROGRAMMING BARCODES Host Transmission Buffers 2 DEFAULT 36 Magellan 1100i Interface Features RS 232 Interface Features PROGRAMMING BARCODES III WRDWWJI HUM u z WWM DEFAULT INI WW DIII t e LET Product Reference Guide 37 Interface Related Features RS 232 Interface Features cont 8 Data Bits DEFAULT 1 Stop Bit DEFAULT UT NU Parity None DEFAULT 38 Magellan 1100i Interface Features RS 232 Interface Features cont Hardware Flow Control Disable Hardware Control The scanner transmits to the host regardless of any activity on the CTS line Enable CTS Flow Control The CTS signal controls transmission of data to the host Enable CTS Scan Control The CTS line must be active for the scanner to read and trans mit data While the CTS line is inactive the scanner remains in a host disabled state following a successful label transmission the CTS signal must transition to inactive and then to active to enable scanning for the next label PROGRAMMING BARCODES Disable Hardware Control DEFAULT Product Reference Guide
50. ads This feature specifies the minimum number of consecutive times an in store printed label must be decoded before it is accepted as good read PROGRAMMING BARCODE Minimum 1 Read DEFAULT Magellan 1100i UPC E UPC E The following options apply to the UPC E symbology Disable Enable UPC E When disabled the scanner will not read UPC E barcodes Enable UPC E DEFAULT Check Digit Transmission Enable this option to transmit the check digit along with UPC E barcode data START END PROGRAMMING BARCODES Send Check Digit DEFAULT Product Reference Guide 79 Symbologies UPC E continued Number System Digit The Number System Digit NSD which is always a zero 0 in the leading position can be optionally included or not with scanned barcode data PROGRAMMING BARCODES Exclude Number System Digit DEFAULT Expand to UPC E to UPC A Enables disables expansion of UPC E labels to UPC A Selecting this feature also changes the symbology ID to match those required for UPC A PROGRAMMING BARCODES Don t Expand UPC E to UPC A DEFAULT 80 Magellan 1100i UPC E UPC E continued Expand UPC E to EAN13 Enables disables expansion of UPC E labels to EAN 13 Selecting this feature also changes the symbology ID to match those required for EAN 13 Don
51. arcode DEFAULT SETTING FOR THIS FEATURE 0001 Set Length 1 DEFAULT SETTING FOR THIS FEATURE 0366 Set Length 2 Product Reference Guide 157 2D Symbologies Datamatrix Disable Enable Datamatrix When disabled the scanner will not read Datamatrix barcodes Enable Datamatrix DEFAULT 158 Magellan 1100i 2D Symbologies Datamatrix continued Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding 1 Scan the START barcode 2 Scan the Fixed Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 0000 if there is only one fixed length by following the Datamatrix Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START barcode 2 Scan the Variable Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the
52. arcodes all check and data char acters are included in the length calculations NOTE Scan the END barcode PROGRAMMING BARCODE Set Length 1 DEFAULT SETTING FOR THIS FEATURE 16 IS FE DEFAULT SETTING FOR THIS FEATURE 04 Set Length 2 Product Reference Guide 141 Symbologies MSI Plessey continued MSI Plessey Stitching Enables disables stitching for MSI Plessey barcodes When parts of an MSI Plessey label are presented to the scanner with this feature enabled the barcode parts will be assembled by the scanners software and the data will be decoded if all barcode proofing requirements are met 7 Only functions when Fixed Length Decoding is enabled NOTE Disable MSI Plessey Stitching DEFAULT 142 Magellan 1100i MSI Plessey MSI Plessey continued Minimum Reads This feature specifies the minimum number of consecutive times an MSI Plessey label must be decoded before it is accepted as good read II EN DEFAULT Nu AA NIWM mm A Product Reference Guide 143 Symbologies Standard 2 of 5 The following options apply to the Standard 2 of 5 symbology Disable Enable Standard 2 of 5 When this feature is disabled the scanner will not read Standard 2 of 5 barcodes Disable Std 2 of 5 DEFAULT
53. assistance 12 Imager Module Software ID t8 Failure 14 CPLD Code Mismatch 1 Field Replaceable Unit FRU Product Reference Guide 5 Getting Started NOTES 6 Magellan 1100i Chapter 2 General Features Double Read Timeout for Linear Labels This Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same linear label again e g two identical items in succession PROGRAMMING BARCODES III TATA IN a DEFAULT B III III Product Reference Guide 7 General Features Double Read Timeout for Linear Labels cont 7 III III z INI LLL LL m i Magellan 1100i Double Read Timeout for 2D Labels Double Read Timeout for 2D Labels This Double Read Timeout feature specifies the minimum allowable time between consecutive good reads of the same PDF 417 Micro PDF 417 Data Matrix QR Code Maxicode Aztec or Composite label 1 8 Seconds DEFAULT Product Reference Guide General Features Label Gone Timeout This feature sets the time after the last label segment is seen before the scanner prepares for a new label Sets the label gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds 10ms or 0 01 seconds To configure this feature scan the START END barcode above t
54. ations NOTE Any value set higher than 2710 will be considered to be 2710 Scan the END barcode Set Length 1 DEFAULT SETTING FOR THIS FEATURE 2710 DEFAULT SETTING FOR THIS FEATURE 0001 Set Length 2 Product Reference Guide 163 2D Symbologies Maxicode Disable Enable Maxicode When disabled the scanner will not read Maxicode labels Disable Maxicode DEFAULT 164 Magellan 1100i 2D Symbologies Maxicode continued Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding 1 Scan the START barcode 2 Scan the Fixed Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 0000 if there is only one fixed length by following the Maxicode Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START barcode 2 S
55. ature specifies when the scanner will provide indication beep and or flash its green LED upon successfully reading a barcode Choices are Good Read Indicate after decode Good Read Indicate after transmit Good Read Indicate after CTS goes inactive then active This option Indicate after CTS goes inactive then active which uses CTS is only valid for RS 232 inter faces NOTE After Decode DEFAULT Product Reference Guide 15 General Features Good Read Beep Control This feature enables disables the scanner s ability to beep upon a successful decode of a barcode PROGRAMMING BARCODE R Disable Iii MI Enable DEFAULT Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high frequency selectable from the list below Controls the beeper s pitch tone PROGRAMMING BARCODES Medium DEFAULT 16 Magellan 1100i LED and Beeper Indicators Good Read Beep Length Specifies the duration of a good read beep PROGRAMMING BARCODES T Im DU os DEFAULT i DL II III AAMA v MAMMA TORT 200msec Product Reference Guide 17 General Features Good Read Beep Volume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels PROGRAMMING BARCODE 7 TAA High DEFAULT This feature
56. barcode proofing requirements are met 7 Only functions when Fixed Length Decoding is enabled NOTE Disable Std 2 of 5 Stitching DEFAULT 148 Magellan 1100i Standard 2 of 5 Standard 2 of 5 continued Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read III emu DEFAULT un D III ms UT AM Product Reference Guide 149 Symbologies NOTES 150 Magellan 1100i 2D Symbologies 7 The features in this section are available ONLY for models with 2D features activated NOTE 2D Symbologies The scanner supports the 2D symbologies barcode types listed below Available options for each 2D symbology are included in this chapter e PDF417 e Maxicode e Micro PDF 417 e Aztec e Datamatrix e Composite Labels QR Code Factory Defaults for the standard RS 232 interface are indicated in bold text throughout 2D Decode Time Max This feature sets the maximum amount of time the software will spend attempting to decode a 2D label Follow these instructions to configure this feature 1 Scan the START barcode 2 Scan the Set 2D Decode Time Max barcode 3 Turn to Alpha Numeric Pad and scan the two digits zero padded representing the desired contrast in decimal notation The configurable range is 01 0xFF by 01 in increments of 10 msec Scan the END bar
57. ble Length Decoding barcode 3 Scan the START END barcode 4 Set Length 1 to the first variable length by following the Code 93 Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the second variable length by following the Code 93 Length 1 Length 2 Pro gramming Instructions below Variable Length Decoding DEFAULT Product Reference Guide 135 Symbologies Code 93 continued Code 93 Length 1 Length 2 Programming Instructions 1 Scan the START barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Appendix C Alpha Numeric Pad and scan the two digits zero padded representing the length in decimal notation 7 For Code 93 barcodes only the data characters are included in the length calculations NOTE 4 Scan the END barcode PROGRAMMING BARCODE Set Length 1 DEFAULT SETTING FOR THIS FEATURE 50 DEFAULT SETTING FOR THIS FEATURE 01 Set Length 2 136 Magellan 1100i Code 93 Code 93 continued Code 93 Stitching Enables disables stitching for Code 93 barcodes When parts of a Code 93 label are presented to the scanner with this feature enabled the barcode parts will be assembled by the scanner s soft ware and the data will be decoded if all barcode proofing requirements are met Disable Code 93 Stitching DEFA
58. c Pad repre senting your desired value Exit programming mode by again scanning the START END barcode above DEFAULT SETTING FOR THIS FEATURE 001 200 msec Set ACK NAK Timeout Value Product Reference Guide 49 Interface Related Features RS 232 Interface Features cont ACK NAK Retry Count This feature sets the number of times for the scanner to retry a label transmission under a retry condition 000 No retry 001 254 Retry for the specified number of times 255 Retry forever To configure this feature scan the START END barcode above to place the unit in Programming Mode then the Set ACK NAK Retry Count followed by the three digits zero padded from the Alphanumeric table in Appendix C Alpha Numeric Pad repre senting your desired retry count Exit programming mode by again scanning the START END barcode above DEFAULT SETTING FOR THIS FEATURE 003 Set ACK NAK Timeout Value 50 Magellan 1100i Interface Features RS 232 Interface Features cont ACK NAK Error Handling This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host Errors include unrecognized host commands and com munication errors such as parity or framing errors Choices are 00 Ignore errors detected recommended setting 01 Process error as valid ACK character ri
59. can the START END barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Appendix C Alpha Numeric Pad and scan the two digits zero padded representing the length in decimal notation For GS1 DataBar Expanded barcodes only the data characters are included in the length calcu lations NOTE 4 Scan the START END barcode Set Length 1 DEFAULT SETTING FOR THIS FEATURE 74 DEFAULT SETTING FOR THIS FEATURE 01 Set Length 2 Product Reference Guide 103 Symbologies GS1 DataBar Expanded Expanded Stacked continued Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Expanded label must be decoded before it is accepted as good read START END PROGRAMMING BARCODES HAM ee DEFAULT UT III WWWWMWI un TULIT 104 Magellan 1100i GS1 DataBar Expanded Expanded Stacked GS1 DataBar Expanded Expanded Stacked continued Coupon Read Control This feature controls coupon reading PROGRAMMING BARCODES Enable UPCA coupon decoding Disable GS1 DataBar coupon decoding DEFAULT Enable GS1 DataBar coupon decoding Disable UPCA coupon decoding Product Reference Guide 105 Symbologies GS1 DataBar Limited The following options apply to the GS1 DataBa
60. can the START END barcode 4 Set Length 1 to the first variable length by following the Code 39 Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the second variable length by following the Code 39 Length 1 Length 2 Pro gramming Instructions below PROGRAMMING BARCODES Variable Length Decoding DEFAULT Product Reference Guide 111 Symbologies Code 39 Length 1 Length 2 Programming Instructions 1 Scan the START END barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Appendix C Alpha Numeric Pad and scan the two digits zero padded representing the length in decimal notation For Code 39 barcodes all check data and full ASCII shift characters are included in the length calculations Start Stop characters are not included NOTE 4 Scan the START END barcode PROGRAMMING BARCODE DEFAULT SETTING FOR THIS FEATURE 02 Set Length 1 DEFAULT SETTING FOR THIS FEATURE 50 Set Length 2 Quiet Zones This feature enables disables the requirement that quiet zones must be present for Code 39 bar codes Don t require Quiet Zones DEFAULT 112 Magellan 1100i Code 39 Code 39 continued Code 39 Stitching Enables disables stitching for Code 39 labels When parts of a Code 39 barcode are prese
61. can the Variable Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the minimum length by following the Maxicode Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the maximum length by following the Maxicode Length 1 Length 2 Pro gramming Instructions below PROGRAMMING BARCODES Variable Length Decoding DEFAULT Product Reference Guide 165 2D Symbologies Maxicode continued Maxicode Length 1 Length 2 Programming Instructions 1 Scan the START barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Alpha Numeric Pad and scan the four digits zero padded representing the length For Maxicode labels only the data characters are included in the length calculations NOTE Any value set higher than 138 will be considered to be 138 Scan the END barcode Set Length 1 DEFAULT SETTING FOR THIS FEATURE 0138 DEFAULT SETTING FOR THIS FEATURE 0001 Set Length 2 166 Magellan 1100i 2D Symbologies Aztec Disable Enable Aztec When disabled the scanner will not read Aztec labels START END PROGRAMMING BARCODES Disable Aztec DEFAULT Enable Aztec Product Reference Guide 167 2D Symbologies Aztec continued Length Control Fixed Length Decoding When fixed l
62. code Set 2D Decode Time Max DEFAULT SETTING FOR THIS FEATURE 350 msec Product Reference Guide 151 2D Symbologies PDF 417 Disable Enable PDF 417 When disabled the scanner will not read PDF 417 barcodes Enable PDF 417 DEFAULT 152 Magellan 1100i 2D Symbologies PDF 417 continued Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding 1 Scan the START barcode 2 Scan the Fixed Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 0000 if there is only one fixed length by following the PDF 417 Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START barcode 2 Scan the Variable Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the minimum length by following the PDF 417 Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the maximum length by following the PDF 417 Len
63. code followed by the three digits zero padded from the Alphanu meric table in Appendix C Alpha Numeric Pad representing your desired length Exit programming mode by again scanning the START END barcode above DEFAULT SETTING FOR THIS FEATURE 010 100 msec Product Reference Guide 59 Interface Related Features Keyboard Wedge cont Intercharacter Delay One half of the delay specified below is inserted between scancodes within each character If the transmission speed is too high the system may not be able to receive all characters You may need to adjust the delay to make the system work properly Selectable from 00 to 99 in 10msec increments To configure this feature scan the START END barcode above to place the unit in Programming Mode then the Set Intercharacter Delay followed by the three digits zero padded from the Alphanumeric table in Appendix C Alpha Numeric Pad representing your desired length Exit programming mode by again scanning the START END barcode above DEFAULT SETTING FOR THIS FEATURE 00 No Delay USB COM Interface Set up This interface uses the Microsoft Windows USB COM driver Before plugging your reader into the host PC please ensure you have already copied the DLS EUG CDC ACM inf file pro vided by Datalogic to your PC and the reader s interface is set to USB COM 1 When you first plug the scanner into the PC Windows will bring
64. coding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding L 2 3 4 Scan the START END barcode Scan the Fixed Length Decoding barcode Scan the START END barcode Set Length 1 to the first fixed length by following the MSI Plessey Length 1 Length 2 Pro gramming Instructions below Set Length 2 to the second fixed length or to 00 if there is only one fixed length by fol lowing the MSI Plessey Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding lu 2 3 4 Scan the START END barcode Scan the Variable Length Decoding barcode Scan the START END barcode Set Length 1 to the first variable length by following the MSI Plessey Length 1 Length 2 Programming Instructions below Set Length 2 to the second variable length by following the MSI Plessey Length 1 Length 2 Programming Instructions below PROGRAMMING BARCODES Variable Length Decoding DEFAULT 140 Magellan 1100i MSI Plessey MSI Plessey continued MSI Plessey Length 1 Length 2 Programming Instructions 1 Scan the START barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Appendix C Alpha Numeric Pad and scan the two digits zero padded representing the length in decimal notation For MSI Plessey b
65. d and Keyboard Wedge A J Parameter Default Setting Keyboard Wedge Interface Type USB Keyboard Label ID Transmission Disable 184 Magellan 1100i Appendix E Keyboard Function Key Mappings Keyboard Model Cross Reference Table E 1 summarizes the keyboard models their defined protocol scancode set and some unique features The remaining tables in this chapter provide the function key maps associated with each of the scancode sets Table E 1 Keyboard Model Cross Reference Func Trans ccancode Key uss Model Type lFID mission Set Ma Couniry Protocol P Mode Support PC XT Foreign ALT Mode Wedge A PC XT ScanSet1 No No AT PS 2 25 286 ped Wedge B AT PS2 Scan Set2 No No PS 2 60 70 80 90 95 Foreign ALT Mode MC don Wedge C AT PS2 Scan Set 1 No No PC XT U S Mode Wedge D PC XT ScanSet1 Yes No AT PS 2 25 286 PS 2 30 286 PS 2 50 50Z Wedge E AT PS2 ScanSet2 Yes Yes PS 2 60 70 80 90 95 U S Mode specific country support PS 2 25 and 30 U S Mode IBM 3xxx Terminals 122 key keyboard IBM 3xxx Terminals Wedge F AT PS2 Scan Set1 Yes No Wedge G AT PS2 Scan Set 3 Yes No Wedge H AT PS2 Scan Set 3 Yes No 102 key keyboard PS55 5530T with Japanese JAPANESE DOS bos Wedgel ATPS2 pos Yes No NEC 9801 Wedge J o NEC 9801 Yes No Product Reference Guide 185 Table E 2 USB Fu
66. d text and a yellow highlighted background indicates the most common default setting for a feature option Manual Conventions The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the scanner Notes contain information necessary for prop erly diagnosing repairing and operating the scanner NOTE AN The CAUTION symbol advises you of actions that could damage equipment or property CAUTION Product Reference Guide 1 Getting Started Connecting the Scanner The scanner kit you ordered to match your interface should provide a compatible cable for your installation Use the appropriate instructions below to connect the scanner to the terminal PC or other host device Upon completing the connection via the appropriate interface instructions below proceed to the Interface Related Features section of this manual and scan the barcode to select the correct interface type RS 232 Serial Connection Turn off power to the terminal PC and connect the scanner to the terminal PC serial port via the RS 232 cable as shown in Figure 1 If the terminal will not support POT Power Off the Terminal to supply scanner power use the approved power supply AC Adapter Plug the AC Adapter barrel connector into the socket on the RS 232 cable con nector and the AC Adapter plug into a standard power outlet Figure 1 RS 232 Serial or USB Connection using A C Adapter
67. e a USB KeYbOAND HE Y E HA FN HR NF FF Yn RR FR FFR A CAPSLOCK Sa lE u aa FF YY FY FYDD Ee USB COM Interface Setzl p ANING RES ER E E FF FFF Chapter 4s Data Editing aaa NGIGING HE O RE EEF EF FE 61 Data Editing OVENIEW asana FFF FFRYNT FFF FFY ETHEEERH UR EL EEUU BERNER RE FYFF FFF FFRAE HU FFYN AND 61 Please Keep lia MING uyak usan OCT RYN ADO UF YD GT ATO 61 Global PRIS aud asas n cde reb A RE NF rt inb TN FFY YH E FYW NN EF RY FR a NN a 62 Label ID Case Conversion ian Character Cn USUI u AN aba ses a a ua HD Y uama 73 Chapter 5 Symbologies i csssssicsssevscsssssscscesssssasssicssssoonssonsssussdssnssacoastssssssssbssnsieisossenusscssnassdasisnsisoontssasedisnsodosnsasdesstssssssicnssesisiesssested 75 UPG A Sumu YY YC EF FO asnu qua OF YW ROF 75 Disable Enabl URGE A simt ctt tot gu Dr tie AERE YF S REPRE GREY AN ONE IN LC EPI qususqayku 75 Le Yt eh lt l o LY STANTS SU OD aane nett esi eri tuse ey RY YF DAD FYFYR RHAFF FFEFRYN FFRAE NF FL FR FF NY ON HNN HF RUE 76 Expand UPC A to BAN P uuu NF RH USE OY GG URBS ANAN YY YGU 76 Number Systern iran SIMISSION ku auqa ua GST Y GOF AA AA FUD OH 77 UPC A Minimum Reads HUNI UPC A In store Minimum Reads 78 Ule a MUTA Disable Enabl amp UP 2B in ua E E E ARIA HUE EA EE E EAE E NANA 79 Check Digit Trans missionens in aean e BTANA EAEE RV SETS a RAEN EORR 79 N tnberSyster DIOE zoe HN TR YR YAR FER F
68. e barcode 2 Digits The scanner will optionally read 2 digit add ons with the UPC EAN label 5 Digits The scanner will optionally read 5 digit add ons with the UPC EAN label Code 128 Add on The scanner will optionally read Code 128 add ons with the UPC EAN label Contact Customer Support for 7 advanced programming of optional nore and conditional add ons Product Reference Guide 95 Symbologies Add ons continued Disable Optional 2 Digit Add ons DEFAULT Disable Optional 5 Digit Add ons DEFAULT Disable Optional Code 128 Add ons DEFAULT 96 Magellan 1100i Add ons Add ons continued 2 Digit Addons Minimum Reads This setting configures the minimum number of times a 2 digit addon must decode before it is marked valid lli nn CEST III DEFAULT LULU rima Uc MAAA Product Reference Guide 97 Symbologies Add ons continued 5 Digit Addons Minimum Reads This setting configures the minimum number of times a 5 digit addon must decode before it is marked valid PROGRAMMING BARCODES Minimum 1 Read DEFAULT III JJ 98 Magellan 1100i GS1 DataBar Omnidirectional Stacked Omnidirectional GS1 DataBar Omnidirectional Stacked Omnidirectional The following options apply to the GS1 DataBar Omnidirectional symbology Disable Enable GS1 DataBar Omnidirectional When this feature
69. edeceddedtesvdostassestviaiauseeiuats Physical Properties Electrical Parameters Erivironimehital Parameters uu u ua Susa a q NU wn Dc ci EU Lu MUI asana 176 Other Parameterns scc o oo Rea nad EM d EP rd a t eed Pu dmt RT a 176 Chapter Bs Cable ap cl S 177 Standard Cable Pinouts Primary Interface Cabl s IILI Ghana tisse toe ASA DYRNOD A UYD AGY 177 RS 232 s IM as 57 uu k CYR O a ND ERCH FUR PP EEEN 177 USB O EM C 178 USB USB Keyboard amp USB COM essssssscssssssssssscssssscssuseccsnsecccusecssnsecssnsecesuseessusecesuseessasseecsneesssuseessnscessusecssnsecesusecssaseeesaseesssseeccaneeessueesesneeessnsesea 178 Keyboard Wedges kiasia a ienaa AN H 178 Appendix C Alpha Numeric Pad PATAPOS PIT ABE PT HYN TL UU YD 179 Appendix D Default Settings 181 Defaultsiby Symbology u u EA E A E EE OEA ERA A E UD 181 Interface Default Exeeptiong2 uu uuu WD YU NY Y NAN UNA 182 IBM Interfaces HA eei RF FFFET YNFTHHEFNFFTFFU FT NU RY FEDW IINE UE HE DN M NN FEYSYDD EI S UP RE 182 RS 232 WiMGOR ANIM OME s 183 KeybaakOS aaa aasan GR OD Gi OY UO DF GE O OFO GYN GOD 184 Appendix E Keyboard Function Key Mappings Keyboard Model Cross Reference Appendix F Host Command vesccsssssccicsscscsessessnenvesscessosesenesvescse
70. ength decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding 1 Scan the START barcode 2 Scan the Fixed Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 0000 if there is only one fixed length by following the Aztec Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START barcode 2 Scan the Variable Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the minimum length by following the Aztec Length 1 Length 2 Program ming Instructions below 5 Set Length 2 to the maximum length by following the Aztec Length 1 Length 2 Program ming Instructions below Variable Length Decoding DEFAULT 168 Magellan 1100i 2D Symbologies Aztec continued Aztec Length 1 Length 2 Programming Instructions 1 Scan the START barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Alpha Numeric Pad and scan the four digits zero padded representing the length
71. ght ODh 0A LF RIGHT arrow inner keypad 6Ah 0B VT TAB left ODh S 0C EF CR FIELD EXIT Make only bAh FOh 5Ah 0D CR CR FIELD EXIT Make Break bAh 0E SO INSERT inner keypad 65h OF SI FIELD 79h 10 DLE FIELD Ch 11 DC1 HOME inner keypad 62h 12 DC2 LEFT arrow inner keypad 61h 13 DC3 DOWN arrow inner keypad 60h 14 DC4 UP arrow inner keypad 63h 15 NAK F6 2Fh 16 SYN F1 07h 17 ETB F2 OFh 18 CAN F3 17h 19 EM F4 1Fh 1A SUB F5 27h 1B ESC ESC 08h 1C FS F7 87h 1D GS F8 BFh 1E RS F9 47h 1F US F10 4Fh Product Reference Guide 189 Table E 7 Japanese DOS Function Key Map ASCII value ASCII code Key Scancode 00h NUL ALT right Make 31h 01h SOH ALT right Break Bih 02h STX ALT left Make 31h 03h ETX ALT left Break Bih 04h EOT CTRL left Make 41h 05h ENQ CTRL left Break Cih 06h ACK CTRL right Make 41h 07h BEL CTRL right Break C1h 08h BS BS 3Eh 09h HT TAB right 3Ch OAh LF RIGHT arrow inner keypad 4Dh 0Bh VT TAB left 3Ch S 0Ch FF Enter right keypad 60h 0Dh CR CR 3Bh 0Eh SO INSERT inner keypad 52h OFh SI PAGE UP inner keypad 49h 10h DLE PAGE DOWN inner keypad 51h 11h DC1 HOME inner keypad 4Ch 12h DC2 LEFT arrow inner keypad 4Bh 13h DC3 DOWN arrow inner keypad 4Ah 14h DC4 UP arrow inner keypad 4Eh 15h NAK F6 6Dh 16h SYN F1 68h 17h ETB F2 69h 18h CAN F3 6Ah 19h EM F4 6
72. gth 1 Length 2 Pro gramming Instructions below Variable Length Decoding DEFAULT Product Reference Guide 153 2D Symbologies PDF 417 continued PDF 417 Length 1 Length 2 Programming Instructions 1 Scan the START barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Alpha Numeric Pad and scan the four digits zero padded representing the length For PDF 417 barcodes only the data characters are included in the length calculations NOTE Any value set higher than 2710 will be considered to be 2710 Scan the END barcode Set Length 1 DEFAULT SETTING FOR THIS FEATURE 2710 DEFAULT SETTING FOR THIS FEATURE 0001 Set Length 2 154 Magellan 1100i 2D Symbologies Micro PDF 417 Disable Enable Micro PDF 417 When disabled the scanner will not read Micro PDF 417 barcodes START END PROGRAMMING BARCODES Disable Micro PDF 417 DEFAULT Enable Micro PDF 417 Product Reference Guide 155 2D Symbologies Micro PDF 417 continued Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will
73. hen fixed length decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding 1 Scan the START END barcode 2 Scan the Fixed Length Decoding barcode 3 Scan the START END barcode 4 Set Length 1 to the first fixed length by following the GS1 DataBar Expanded Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 00 if there is only one fixed length by fol lowing the GS1 DataBar Expanded Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START END barcode 2 Scan the Variable Length Decoding barcode 3 Scan the START END barcode 4 Set Length 1 to the first variable length by following the GS1 DataBar Expanded Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second variable length by following the GS1 DataBar Expanded Length 1 Length 2 Programming Instructions below Variable Length Decoding DEFAULT 102 Magellan 1100i GS1 DataBar Expanded Expanded Stacked GS1 DataBar Expanded Expanded Stacked continued GS1 DataBar Expanded Length 1 Length 2 Programming Instructions 1 S
74. ht Fh 0A LF RIGHT arrow inner keypad 4Dh EO 0B VT AB left Fh S 0C FF Enter inner keypad 1Ch EO 0D CR CR 1Ch OE SO INSERT inner keypad b2h EO OF SI PAGE UP inner keypad 49h EO 10 DLE PAGE DOWN inner keypad 51h EO 11 DC1 HOME inner keypad 47h EO 12 DC2 LEFT arrow inner keypad MBh EO 13 DC3 DOWN arrow inner keypad 50h EO 14 DC4 UP arrow inner keypad 48h EO Table E 4 Scanset 2 Function Key Map ie in ASCII code Key Scancode 00 NUL ALT right Make EOh 11h 01 SOH ALT right Break EOh FOh 11h 02 STX ALT left Make 11h 03 ETX ALT left Break Foh 11h 04 EOT CTRL left Make 14h 05 ENQ CTRL left Break FOh 14h 06 ACK CTRL right Make EOh 14h 07 BEL CTRL right Break EOh FOh 14h 08 BS BS 66h 09 HT TAB right ODh 0A LF RIGHT arrow inner keypad 74h EO 0B VT TAB left ODh S 0C FE Enter right keypad pAh E0 0D CR CR bAh 0E SO INSERT inner keypad 70h EO OF SI PAGE UP inner keypad Dh EO 10 DLE PAGE DOWN inner keypad 7Ah EO 11 DC1 HOME inner keypad 6Ch EO 12 DC2 LEFT arrow inner keypad 6Bh EO 13 DC3 DOWN arrow inner keypad 72h EO 14 DC4 UP arrow inner keypad 75h EO 15 NAK F6 OBh 16 SYN F1 05h 17 ETB F2 06h 18 CAN F3 04h Product Reference Guide 187 19 EM F4 OCh 1A SUB F5 03h 1B ESC ESC 76h 1C FS F7 83h 1D GS F8 OAh 1E R
75. ing barcode Scan the START END barcode Set Length 1 to the first variable length by following the Standard 2 of 5 Length 1 Length 2 Programming Instructions below Set Length 2 to the second variable length by following the Standard 2 of 5 Length 1 Length 2 Programming Instructions below PROGRAMMING BARCODES Variable Length Decoding DEFAULT 146 Magellan 1100i Standard 2 of 5 Standard 2 of 5 continued Standard 2 of 5 Length 1 Length 2 Programming Instructions 1 Scan the START barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Appendix C Alpha Numeric Pad and scan the two digits zero padded representing the length in decimal notation For Standard 2 of 5 barcodes all check and data characters are included in the length calcula tions NOTE Scan the END barcode PROGRAMMING BARCODE Set Length 1 ULT SETTING FOR THIS FEATUR DEFAULT SETTING FOR THIS FEATURE 08 Set Length 2 Product Reference Guide 147 Symbologies Standard 2 of 5 continued Standard 2 of 5 Stitching Enables disables stitching for Standard 2 of 5 barcodes When parts of a Standard 2 of 5 label are presented to the scanner with this feature enabled the barcode parts will be assembled by the scanners software and the data will be decoded if all
76. ing the Code 128 Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the second fixed length or to 00 if there is only one fixed length by fol lowing the Code 128 Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START barcode 2 Scan the Variable Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the first variable length by following the Code 128 Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the second variable length by following the Code 128 Length 1 Length 2 Programming Instructions below Variable Length Decoding DEFAULT 118 Magellan 1100i Code 128 Code 128 continued Code 128 Length 1 Length 2 Programming Instructions 1 Scan the START barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Appendix C Alpha Numeric Pad and scan the two digits zero padded representing the length in decimal notation For Code 128 barcodes only the data charac ters are included in the length calculations NOTE 4 Scan the END barcode ING BARCODE PROGRAMMIN Set Length 1 DEFAULT SETTING FOR THIS FEATURE 80 DEFAULT SETTING FOR THIS FEATURE 01 Set Length 2 Code 128 Conversion to Code 39 Enables disables expansio
77. is disabled the scanner will not read GS1 DataBar Omnidirectional barcodes Disable GS1 DataBar Omnidirectional DEFAULT START END x UCC EAN 128 Emulation When enabled GS1 DataBar Omnidirectional barcodes will be translated to the UCC EAN 128 label data format Disable UCC EAN 128 Emulation DEFAULT Product Reference Guide 99 Symbologies GS1 DataBar Omnidirectional Stacked Omnidirectional continued Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Omnidirec tional label must be decoded before it is accepted as good read START END PROGRAMMING BARCODES III EN DEFAULT un III III mu III 100 Magellan 1100i GS1 DataBar Expanded Expanded Stacked GS1 DataBar Expanded Expanded Stacked The following options apply to the GS1 DataBar Expanded symbology Disable Enable GS1 DataBar Expanded When this feature is disabled the scanner will not read GS1 DataBar Expanded barcodes ROGRAMMING BARCODE P Disable GS1 DataBar Expanded DEFAULT GS1 128 Emulation When enabled GS1 DataBar Expanded barcodes will be translated to the GS1 128 label data format Disable GS1 128 Emulation DEFAULT Product Reference Guide 101 Symbologies GS1 DataBar Expanded Expanded Stacked continued Length Control Fixed Length Decoding W
78. ld look as follows after the character conversion BG25TB82 The A characters were converted to the B character and the 1 characters were converted to the numeral 2 character Nothing is done with the last two character pairs since they are all FF To set Character Conversion 1 Scan the START END barcode 2 Scan the Character Conversion barcode 3 Determine the desired string Up to sixteen positions can be determined as in the above example Next turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string 7 The positions not used must be filled with the character F NOTE 4 Turn to Appendix C Alpha Numeric Pad and scan the barcodes representing the hex charac ters determined in the previous step When the last character is scanned the scanner will sound a triple beep 5 Scan the START END barcode to exit Programming Mode DEFAULT FFFFFFFFFFFFFFFF hex no conversion Character Conversion SETTING II THIS FEATURE Product Reference Guide 73 Data Editing NOTES 74 Magellan 1100i Chapter 5 Symbologies The scanner supports the following symbologies barcode types Options for each symbology are included in this chapter L Seder UPC E Code 128 EAN 13 nterleaved 2 of 5 EAN 8 Codabar GS1 DataBar Omnidirectional Stacked Omnidirectio
79. le Check Digit Calculation DEFAULT 122 Magellan 1100i Interleaved 2 of 5 Interleaved 2 of 5 continued Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding 1 2 Bi 4 Scan the START barcode Scan the Fixed Length Decoding barcode Scan the END barcode Set Length 1 to the first fixed length by following the Interleaved 2 of 5 Length 1 Length 2 Programming Instructions below Set Length 2 to the second fixed length or to 00 if there is only one fixed length by fol lowing the Interleaved 2 of 5 Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 2 3 4 Scan the START barcode Scan the Variable Length Decoding barcode Scan the END barcode Set Length 1 to the first variable length by following the Interleaved 2 of 5 Length 1 Length 2 Programming Instructions below Set Length 2 to the second variable length by following the Interleaved 2 of 5 Length 1 Length 2 Programming Instructions below PROGRAMMING BARCODES Variable Length Decoding DEFAULT Product Reference G
80. mited Label ID Character s FAULT SETTING FOR THIS FEATURE Set Code 39 Label ID Character s DEFAULT SETTING FOR THIS FEATURE A 41 hex Set Pharmacode 39 Label ID Character s DEFAULT SETTING FOR THIS FEATURE 23 hex Set Code 128 Label ID Character s FAULT SETTING FOR THIS FEATURE i 69 hex Set 2 of 5 Label ID Character s Product Reference Guide 69 Data Editing Label ID cont Set Codabar Label ID Character s EFAULT SETTING FOR THIS FEATURE amp 26 hex ULT SETTING FOR THIS FEATURE 2 Set Code 93 Label ID Character s FAULT SETTING FOR THIS FEATURE 4 Set Code 11 Label ID Character s DEFAULT SETTING FOR THIS FEATURE 40 hex Set MSI Plessey Label ID Character s DEFAULT SETTING FOR THIS FEATURE s 73 hex Set Std 2 of 5 Label ID Character s ULT SETTING FOR THIS FEA Set PDF 417 Label ID Character s FAULT SETTING FOR THIS FEATURE Dm 446D hex
81. n of Code 128 labels to Code 39 OGRAMMING BARCODE PR Disable DEFAULT Enable JI Product Reference Guide 119 Symbologies Code 128 continued Code 128 Stitching Enables disables stitching for Code 128 labels When parts of a Code 128 barcode are presented to the scanner with this feature enabled the barcode parts will be assembled by the scanner s software and the data will be decoded if all barcode proofing requirements are met Disable Code 128 Stitching DEFAULT Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read PROGRAMMING BARCODES Im md DEFAULT MM TA EAM UT II 120 Magellan 1100i Interleaved 2 of 5 Interleaved 2 of 5 The following options apply to the Interleaved 2 of 5 I 2 of 5 symbology Disable Enable Interleaved 2 of 5 When this feature is disabled the scanner will not read Interleaved 2 of 5 barcodes Disable Interleaved 2 of 5 DEFAULT Check Digit Calculation When enabled the scanner will calculate the check digit of the labels Disable Check Digit Calculation DEFAULT Product Reference Guide 121 Symbologies Interleaved 2 of 5 continued Check Digit Transmit Enable this option to transmit the check digit with scanned barcode data Disab
82. n the END barcode 4 Set Length 1 to the first fixed length by following the Codabar Length 1 Length 2 Program ming Instructions below 5 Set Length 2 to the second fixed length or to 00 if there is only one fixed length by fol lowing the Codabar Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START barcode 2 Scan the Variable Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the first variable length by following the Codabar Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the second variable length by following the Codabar Length 1 Length 2 Programming Instructions below Variable Length Decoding DEFAULT Product Reference Guide 129 Symbologies Codabar continued Codabar Length 1 Length 2 Programming Instructions 1 Scan the START barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Appendix C Alpha Numeric Pad and scan the two digits zero padded representing the length in decimal notation For Codabar barcodes all start stop check and data characters are included in the length calcu lations NOTE 4 Scan the END barcode PROGRAMMING BARCODES Set Length 1 DEFAULT SETTING FOR THIS FEATURE 50 DEFAULT SETTING FOR THIS FEATURE 03 Set Length 2
83. nal GS1 DataBar Expanded Expanded Stacked GS1 DataBar Limited Code 39 Code 93 MSI Plessey Standard 2 of 5 Factory Defaults for the standard RS 232 interface are indicated in bold text throughout this section Reference Appendix D Default Settings for default exceptions for your interface UPC A Disable Enable UPC A When disabled the scanner will not read UPC A barcodes Enable UPC A DEFAULT Product Reference Guide 75 Symbologies UPC A continued Check Digit Transmission Enable this option to transmit the check digit along with UPC A barcode data Send Check Digit DEFAULT START END x Expand UPC A to EAN 13 Expands UPC A data to the EAN 13 data format Selecting this feature also changes the sym bology ID to match those required for EAN 13 Don t Expand to EAN 13 DEFAULT 76 Magellan 1100i UPC A UPC A continued Number System Transmission This feature enables disables transmission of UPC A System Number PROGRAMMING BARCODES Enable Number System Transmission DEFAULT UPC A Minimum Reads This feature specifies the minimum number of consecutive times a UPC A label must be decoded before it is accepted as good read Minimum 1 Read DEFAULT lll III MN Product Reference Guide 77 Symbologies UPC A continued UPC A In store Minimum Re
84. nction Key Usage Map Modifier ASCII Key value Usage Name Scancod 00 NUL ALT right Make 40h 00h 01 SOH ALT right Break 00h 00h 02 STX F11 00h 44h 03 ETX F12 Doh 45h 04 EOT GUI right Make 80h 00h 05 ENQ GUI right Break 00h 00h 06 ACK CTRL right Make 10h 00h 07 BEL CTRL right Break 00h 00h 08 BS BS 00h 2Ah 09 HT TAB right 00h 2Bh DA LF RIGHT arrow inner keypad 00h 4Fh 0B NT TAB left 02h 2Bh oc FF Enter right keypad 00h 58h 0D CR R 00h 28h DE SO INSERT inner keypad 00h 49h OF SI PAGE UP inner keypad 00h 4Bh 10 DLE PAGE DOWN inner keypad 00h 4Eh 11 DC1 HOME inner keypad 00h 4Ah 12 DC2 LEFT arrow inner keypad 00h 50h 13 DC3 DOWN arrow inner keypad 00h 51h 14 DC4 UP arrow inner keypad 00h 52h 15 NAK F6 00h 3Fh 16 SYN F1 00h 3Ah 17 ETB F2 00h 3Bh 18 CAN F3 00h 3Ch 19 EM F4 00h 3Dh 1A SUB F5 00h 3Eh 1B ESC ESC 00h 29h 1C FS F7 00h 40h 1D GS F8 00h 41h 1E RS F9 00h 42h 1F US F10 00h 43h 186 Magellan 1100i Keyboard Model Cross Reference Table E 3 Scanset 1 Function Key Map ie ASCII code Key Scancode 00 NUL ALT right Make EOh 38h 01 SOH ALT right Break E0h B8h 02 STX ALT left Make 98h 03 ETX ALT left Break B8h 04 EOT CTRL left Make 1Dh 05 ENQ CTRL left Break QDh 06 ACK CTRL right Make E0h 1Dh 07 BEL CTRL right Break E0h 9Dh 08 BS BS Eh 09 HT AB rig
85. nd Beeper Indicators LED and Beeper Indicators Power On Alert Disables or enables the indication a single beep that the scanner has finished all its power up tests and is now ready for operation Disable Ill III Enable DEFAULT ERI Active State High This setting specifies the active state polarity of the External Read Indicator signal to High the inactive state is the opposite polarity Contact Technical Support for assistance in changing the ERI Active State to Low if needed Configuration of this feature is available only through use of a special cable Product Reference Guide 13 General Features ERI Timeout Specifies the amount of time the External Read Indicator ERI signal is held active for a good read Sets the ERI timeout duration using hex values from 000 to 255 in increments of ten milliseconds 10ms or 0 01 seconds To config4 ure this feature scan the START END barcode above to place the unit in Programming Mode then the Set ERI Timeout followed by the two digits zero padded from the Alphanumeric table in Appendix C Alpha Numeric Pad representing the desired time value Exit programming mode by scanning the START END barcode again DEFAULT SETTING FOR THIS FEATURE 20 milliseconds 02 Set ERI Timeout 14 Magellan 1100i LED and Beeper Indicators Good Read When to Indicate This fe
86. ne of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding 1 Scan the START barcode 2 Scan the Fixed Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 0000 if there is only one fixed length by following the QR Code Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START barcode 2 Scan the Variable Length Decoding barcode 3 Scan the END barcode 4 Set Length 1 to the minimum length by following the QR Code Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the maximum length by following the QR Code Length 1 Length 2 Pro gramming Instructions below Variable Length Decoding DEFAULT 162 Magellan 1100i 2D Symbologies QR Code continued QR Code Length 1 Length 2 Programming Instructions 1 Scan the START barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Alpha Numeric Pad and scan the four digits zero padded representing the length For QR Code labels only the data characters are included in the length calcul
87. ns and programming barcodes available in that section and also the Data Editing and Symbologies chapters of this manual Using the Programming Barcodes This manual contains feature descriptions and barcodes which allow you to reconfigure your scanner Some programming barcode labels like the label below for resetting defaults require only the scan of that single label to enact the change Most of the programming labels in this manual however require the scanner to be placed in Programming Mode prior to scanning them Scan a START END barcode once to enterProgramming Mode Once the scanner is in Programming Mode you can scan a number of parameter settings before scanning the START END barcode a second time which will then accept your changes exit Programming Mode and return the scanner to normal operation Resetting the Standard Product Defaults If you are unsure of what programming options are in your scanner or you ve changed some options and want the factory settings restored scan the Standard Product Default Settings bar code below This will copy the factory configuration for the currently active interface to the cur rent configuration Standard Product Default Settings The programming section lists the factory default settings for each of the menu commands for the standard RS 232 interface in BOLD text on the following pages Exceptions to default set tings for the other interfaces can be found in Appendix D Default Settings
88. nted to the scanner with this feature enabled the barcode parts will be assembled by the scanner s soft ware and the data will be decoded if all barcode proofing requirements are met PROGRAMMING BARCODE Disable Code 39 Stitching DEFAULT Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read RAMMING BARCODE PR Minimum 1 Read DEFAULT I All Product Reference Guide 113 Symbologies Code 32 Italian Pharmacode The following options apply to the Code 32 Italian Pharmacode symbology Disable Enable Code 32 Italian Pharmacode When this feature is disabled the scanner will not read Code 32 Italian Pharmacode barcodes START END PROGRAMMING BARCODES Disable Code 32 Italian Pharmacode DEFAULT Start Stop Characters Enables or disables transmission of Code 32 Italian Pharmacode start stop characters Don t Transmit Start Stop Characters DEFAULT PROGRAMMING BARCODES 114 Magellan 1100i Code 32 Italian Pharmacode Code 32 Italian Pharmacode continued Check Character Transmit Enable this option to transmit the check character with scanned barcode data START END PROGRAMMING BARCODES Disable Check Char Transmission Enable Check Char Transmission DEFAULT
89. nual that is complete and accurate however Datalogic reserves the right to change any specification at any time without prior notice Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U All other brand and product names may be trademarks of their respective owners Magellan is a registered trademark of Datalogic Scanning Inc in many countries including the U S A and the E U This product may be covered by one or more of the following patents 4603262 4639606 4652750 4672215 4699447 4709369 4749879 4786798 4792666 4794240 4798943 4799164 4820911 4845349 4861972 4861973 4866257 4868836 4879456 4939355 4939356 4943127 4963719 4971176 4971177 4991692 5001406 5015831 5019697 5019698 5086879 5115120 5144118 5146463 5179270 5198649 5200597 5202784 5208449 5210397 5212371 5212372 5214270 5229590 5231293 5232185 5233169 5235168 5237161 5237162 5239165 5247161 5256864 5258604 5258699 5260554 5274219 5296689 5298728 5311000 5327451 5329103 5330370 5347113 5347121 5371361 5382783 5386105 5389917 5410108 5420410 5422472 5426507 5438187 5440110 5440111 5446271 5446749 5448050 5463211 5475206 5475207 5479011 5481098 5491328 5493108 5504350 5508505 5512740 5541397 5552593 5557095 5563402 5565668 5576531
90. o place the unit in Programming Mode then the Set Linear Label Gone Timeout followed by the three digits zero padded from the Alphanumeric table in Appendix C Alpha Numeric Pad repre4 senting the desired time value Exit programming mode by scanning the START END barcode again DEFAULT SETTING FOR THIS FEATURE 320 milliseconds 032 Productivity Index Reporting PIR Set Linear Label Gone Timeout When PIR is enabled label quality data is appended to decoded data before being presented to the POS The PIR feature allows the scanner to provide information to an external computer indicating how easy the label was to read This value added feature is a factory programmed option Contact your dealer for information about upgrading your system to include this advanced NOTE capability START END Disable DEFAULT 10 Magellan 1100i Sleep Mode Sleep Mode This feature specifies the amount of time with no barcode reads before the scanner enters sleep mode TT PROGRAMMINGBARCODES A ss IIIIIIIIII TTTIITITTT MATT IIIIIIIII MAT IIIIIIII Product Reference Guide 11 General Features Sleep Mode cont START END 6 Minutes 7 Minutes 8 Minutes 9 Minutes 10 Minutes DEFAULT 12 Minutes 15 Minutes 30 Minutes 1 Hour 12 Magellan 1100i LED a
91. odabar continued Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as a good read WWW si DEFAULT _ IN Nn AN Im Product Reference Guide 133 Symbologies Code 93 The following options apply to the Code 93 symbology Disable Enable Code 93 When this feature is disabled the scanner will not read Code 93 barcodes Disable Code 93 DEFAULT 134 Magellan 1100i Code 93 Code 93 continued Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding 1 Scan the START END barcode 2 Scan the Fixed Length Decoding barcode 3 Scan the START END barcode 4 Set Length 1 to the first fixed length by following the Code 93 Length 1 Length 2 Program ming Instructions below 5 Set Length 2 to the second fixed length or to 00 if there is only one fixed length by fol lowing the Code 93 Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START END barcode 2 Scan the Varia
92. ode data In this example well add a dollar sign as a prefix 2 Scan the START barcode Scan the SET PREFIX barcode 4 Reference the ASCII Chart on the inside back cover of this manual to find the hex value assigned to the desired character The corresponding hex number for the character is 24 To enter this selection code scan the 2 and 4 barcodes from Appendix C Alpha Numeric Pad 5 Scan the END barcode once to finish the string then scan END again to exit Program ming Mode If all 20 characters will be used in the prefix or suffix do not scan the END barcode to finish the string It is done automatically NOTE 6 The resulting message string would appear as follows Scanned barcode data 12345 Resulting message string output 12345 62 Magellan 1100i Global Prefix Suffix Global Prefix Suffix cont Sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to 7F To configure this feature scan the START END barcode above to place the unit in Programming Mode then the Set Prefix or Set Suffix followed by the digits from the Alphanumeric table in Appendix C Alpha Numeric Pad representing your desired character s Reference the section Example Setting a Prefix for more information Exit programming mode by scanning the START END barcode again scan START END twice if less than 20 characters have been selected
93. ode of operation after reading a barcode before reverting to Omni directional Mode Medium Duration DEFAULT Product Reference Guide 21 General Features Wake Up Intensity This feature indicates the percentage of ambient light change which will trigger the scanner to wake up from Sleep Mode Lower settings provide greater sensitivity The seelectable range for this setting is 5 to 15 LIU i NT III I DEFAULT III NAT 22 Magellan 1100i Image Capture Wake Up Intensity cont PROGRAMMING BARCODES n LU LULU li HII Image Capture We This function is ONLY available for scanners having a button Image capture requires that the scanner use the Standard RS 232 or USB COM interface ONLY NOTE The scanner reverts to default reading mode after image capture and transfer How to Capture an Image To initiate an Image Capture scan the IMAGE CAPTURE label below and press the button A targeting pointer will be illuminated while the button is pressed Upon release of the button the image is captured and transmitted to the host If the button is not pushed within 30 seconds the scanner will return to barcode reading scanning mode By default images are captured as 752 x 480 JPEG format with a minimum compression ratio and are displayed via the host application software IMAGE CAPTURE Product Reference
94. onsecutive times an Interleaved 2 of 5 label must be decoded before it is accepted as good read Minimum 1 Read DEFAULT HA III dcin 126 Magellan 1100i Codabar Codabar The following options apply to the Codabar symbology Disable Enable Codabar When this feature is disabled the scanner will not read Codabar barcodes Disable Codabar DEFAULT Check Character Verification When enabled the scanner will verify the check character of the labels Disable Check Char Verification DEFAULT Product Reference Guide 127 Symbologies Check Character Transmit Enable this option to transmit the check character with scanned barcode data START END PROGRAMMING BARCODES Disable Check Char Transmission Enable Check Char Transmission DEFAULT 128 Magellan 1100i Codabar Codabar continued Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding 1 Scan the START barcode 2 Scan the Fixed Length Decoding barcode 3 Sca
95. osite Label ID Character s DEFAULT SETTING FOR THIS FEATURE RL 524C0000 hex Set GS1 DataBar Expanded 2D Composite Label ID Character s DEFAULT SETTING FOR THIS FEATURE RX 52340000 hex Set QR Code Label ID Characters Product Reference Guide 71 Data Editing Case Conversion This feature can convert scanned barcode data to either all lower case a through z or all upper case A through Z characters Case conversion affects ONLY scanned barcode data and does not affect Label ID Prefix Suffix or other appended data NOTE Disable DEFAULT 72 Magellan 1100i Character Conversion Character Conversion Character conversion is an eight byte configuration item The eight bytes are 4 character pairs represented in hexadecimal ASCII values The first character in the pair is the character that will be converted The second character in the pair is the character to convert to If the charac ter to convert in a pair is FF then no conversion is done For example if you have the character conversion configuration item set to the following 41423132FFFFFFFF The first pair is 4142 or AB 41 hex is an ASCII capital A 42 hex is an ASCII capital B and the second pair is 3132 or 12 31 hex is an ASCII 1 32 is an ASCII 2 The other two pairs are FFFF and FFFF With the label AG15TA81 it wou
96. phone 33 01 64 86 71 00 france scanning datalogic com Germany Datalogic Scanning GmbH Telephone 49 0 61 51 93 58 0 germany scanning datalogic com India Datalogic Scanning India Telephone 91 22 64504739 india scanning datalogic com Italy Datalogic Scanning SpA Telephone 39 0 39 62903 1 italy scanning datalogic com Japan Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 591 3222 latinamerica scanning datalogic com Singapore Datalogic Scanning Singapore PTE LTD Telephone 65 6435 1311 singapore scanning datalogic com Iberia Datalogic Scanning SAS Sucursal en Espana Telephone 34 91 746 28 60 spain scanning datalogic com United Kingdom Datalogic Scanning LTD Telephone 44 0 1582 464900 uk scanning datalogic com wv DATALOGIC www scanning datalogic com Datalogic Scanning Inc 959 Terry Street Eugene OR 97402 USA Telephone 541 683 5700 Fax 541 345 7140 2005 2010 Datalogic Scanning Inc R44 3035 Rev C Apr 2010
97. r Limited symbology Disable Enable GS1 DataBar Limited When this feature is disabled the scanner will not read GS1 DataBar Limited barcodes START END PROGRAMMING BARCODES Disable GS1 DataBar Limited DEFAULT GS1 128 Emulation When enabled GS1 DataBar Limited barcodes will be translated to the GS1 128 label data for mat Disable GS1 128 Emulation DEFAULT 106 Magellan 1100i GS1 DataBar Limited GS1 DataBar Limited continued Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Limited label must be decoded before it is accepted as good read IH ue DEFAULT cT HII III a UT III Product Reference Guide 107 Symbologies Code 39 The following options apply to the Code 39 symbology Disable Enable Code 39 When this feature is disabled the scanner will not read Code 39 barcodes START END PROGRAMMING BARCODES Enable Code 39 DEFAULT Check Character Calculation When enabled the scanner will calculate the check character of the labels Turn this option on only when a checksum is present in the Code 39 labels Disable Check Char Calculation DEFAULT 108 Magellan 1100i Code 39 Check Character Transmit Enable this option to transmit the check character with scanned ba
98. ransmission conflicts Disable Host Echo DEFAULT 42 Magellan 1100i Interface Features RS 232 Interface Features cont Host Echo Quiet Interval This setting specifies the time interval of RS 232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the barcode data that has just been scanned to the host PROGRAMMING BARCODES Host Echo Quiet Interval 10msec DEFAULT HHIH ee ame Product Reference Guide 43 Interface Related Features Host Echo Quiet Interval cont RAMMING BARCODE PR Signal Voltage Normal TTL Specifies whether the RS 232 interface provides TTL levels on the output pins TxD and RTS PROGRAMMING BARCODE Signal Voltage Normal RS 232 DEFAULT 44 Magellan 1100i Interface Features RS 232 Invert Enables disables inversion of RS 232 TXD and RXD signals OGRAMMING BARCODE PR Disable RS 232 Invert DEFAULT Beep on ASCII BEL Enables disables ability of scanner to beep sound a good read tone on receiving an ASCII BEL 07 hex OGRAMMING BARCODE Po PROGRAMMING BARCODES Enable Beep on ASCII BEL DEFAULT Product Reference Guide 45 Interface Related Features Beep on Not on File Select for the host to beep or not when a not on file host command condition is detected by the host
99. rcode data PROGRAMMING BARCODES Enable Check Char Transmission DEFAULT Start Stop Characters Enables disables transmission of Code39 start and stop characters Don t Transmit Start Stop Characters DEFAULT Product Reference Guide 109 Symbologies Code 39 Full ASCII Enables disables the translation of Code 39 characters to Code 39 full ASCII characters Disable Code 39 Full ASCII DEFAULT 110 Magellan 1100i Code 39 Code 39 continued Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a barcode if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi mum length Configuring Fixed Length Decoding 1 Scan the START END barcode 2 Scan the Fixed Length Decoding barcode 3 Scan the START END barcode 4 Set Length 1 to the first fixed length by following the Code 39 Length 1 Length 2 Program ming Instructions below 5 Set Length 2 to the second fixed length or to 00 if there is only one fixed length by fol lowing the Code 39 Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START END barcode 2 Scan the Variable Length Decoding barcode 3 S
100. s start with 978 ISBN Example Barcode data 9789572222720 Output 9572222724 OGRAMMING BARCODE PR Disable ISBN DEFAULT 84 Magellan 1100i EAN 13 EAN 13 continued Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read UU im DEFAULT cm II I ATA Product Reference Guide 85 Symbologies EAN 8 The following options apply to the EAN 8 symbology Disable Enable EAN 8 When disabled the scanner will not read EAN 8 barcodes PROGRAMMING BARCODES Enable EAN 8 DEFAULT Check Digit Transmission Enable this option to transmit the check Digit along with EAN 8 barcode data ROGRAMMING BARCODE P Send Check Digit DEFAULT 86 Magellan 1100i EAN 8 EAN 8 continued Expand EAN 8 to EAN 13 Expands EAN 8 data to the EAN 13 data format Selecting this feature also changes the symbology ID to match those required for EAN 13 PROGRAMMING BARCODES Don t Expand to EAN 13 DEFAULT Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 label must be decoded before it is accepted as good read PROGRAMMING BARCODES III mum DEFAULT MM HII LA _ III Product Reference Guide 87 Symbologies
101. s the minimum consecutive decodes of an EAN two label pair before it is accepted as good read TL I E R DEFAULT MM IL WU MA DL Product Reference Guide 93 Symbologies Price Weight Check Digit Enables disables calculation and verification of price weight check digits Applies to all UPC A labels with a number system character of 2 and EAN JAN 13 labels with a Flag1 digit of 2 NOTE Here are the available options for this feature Disable Enable 4 digit price wt check digit calculation Enable 5 digit price wt check digit calculation Enable European 4 digit price weight check digit calculation Enable European 5 digit price weight check digit calculation LULU BC den DEFAULT Price Weight Check Digit Enable 4 digit price wt II III Price Weight Check Digit Enable 5 digit price wt Price Weight Check Digit Enable European 4 digit price wt NS 94 Magellan 1100i Add ons Add ons Add ons or supplemental characters are commonly added to the end of UPC EAN barcodes The scanner will read the add ons if they are enabled and in the field of view Three add on types are supported 2 digit 5 digit and Code 128 add ons Supported options are None This option directs the scanner to ignore add on portion of a UPC EAN barcode but still read the main portion of th
102. sk of lost label data 02 Process error as valid NAK character risk of duplicate label data Ignore Errors Detected DEFAULT Process error as valid ACK character III II II Process error as valid NAK character Product Reference Guide 51 Interface Related Features RS 232 Interface Features cont Transmission Failure Indication Enables disables bad label indication upon transmission failure PROGRAMMING BARCODE TW Disable Transmission Error Indication Enable Transmission Error Indication DEFAULT USB OEM Interface Features USB OEM Device usage The USB OEM protocol allows for the scanner to be identified as one of two different types of barcode scanners Depending on what other scanners you may already have connected to a USB OEM POS you may need to change this setting to enable all devices to communicate Options are Table Top Scanner Handheld Scanner OGRAMMING BARCODE PR Configure as Table Top Scanner DEFAULT 52 Magellan 1100i Interface Features IBM IBM Transmit Labels in Code 39 Format This feature enables disables scanner s ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host This applies to Code 128 Codabar and Code 93 for USB OEM Code 128 Codabar and Code 93 for IBM Port 5B and Codabar and Code 93 for IBM Port 9B
103. ssenonssneecsessescedouesesssedsoseseousessesdessensseousessessessessvesoss TO Accepting RS 232 GCOmimianids uu anu ER ER I ERASMI IEEE DC GYN FAGU 193 Appendix G Sample Symbols L ett uU CROG IB SL EDN Yd FA CUR Nb GOF Nb EY a RF ae EV O 195 Lees yr ero enna less ER EE AA AA LM 195 2D Sample Symbols M 197 COmbosite Sarmple mni O le FN GY EF UTR Y Us EE A AA 198 Product Reference Guide v NOTES Magellan 1100i Chapter 1 Getting Started The Magellan 1100i Omni Directional Imaging Scanner offers hands free scanning for small easily handled items and handheld scanning for bulkier items Its aggressive imaging perfor mance and intuitive operation reduces user training and speeds checkout for better customer service About This Manual This manual presents advanced user information which includes connection programming product and cable specifications and other useful references For additional information such as installation maintenance troubleshooting and warranty information see the Quick Refer ence Guide QRG Copies of other publications for this product are downloadable free of charge from the website listed on the back cover of this manual On leaving the factory units are programmed for the most common terminal and communica tions settings If you need to change these settings custom programming can be accomplished by scanning the barcodes in this guide Bol
104. st This feature sets the image contrast value Follow these instructions to configure this feature 1 Scan the START barcode 2 Scan the Set Image Contrast barcode 3 Turn to Alpha Numeric Pad and scan the two digits zero padded representing the desired contrast in decimal notation The configurable range is 01 0x0A by increments of 01 Scan the END barcode PROGRAMMING BARCODE Set Image Contrast DEFAULT SETTING FOR THIS FEATURE 09 Product Reference Guide 25 General Features Cell Phone Mode Cell Phone Mode enables the scanner to read barcodes on a cell phone display Cell Phone Mode Enable Enables disables Cell Phone Mode Cell Phone Mode Disable DEFAULT 26 Magellan 1100i Cell Phone Mode Cell Phone Detection Sensitivity These settings control various pixel characteristics in order to optimize cell phone detection Follow these instructions to configure this feature I 2 o Determine which sensitivity level is desired high medium or low Scan the START barcode to place the scanner in Programming Mode Scan the three barcodes for the detection sensitivity desired scanning of THREE barcodes to set the level For example to set a high detec tion sensitivity level scan barcodes HIGH 1 HIGH 2 and HIGH 3 Unlike typical feature settings Cell Phone Detection Sensitivity requires the NOTE Scan the END barcode PROGRAMMING BARCODE
105. uide 123 Symbologies Interleaved 2 of 5 continued Interleaved 2 of 5 Length 1 Length 2 Programming Instructions 1 Scan the START barcode 2 Scan either the Set Length 1 or Set Length 2 barcode 3 Turn to Appendix C Alpha Numeric Pad and scan the two digits zero padded representing the length in decimal notation For Interleaved 2 of 5 barcodes lengths must be an even number Additionally all check and data characters are included in the length calcula NOTE tions 4 Scan the END barcode Set Length 1 DEFAULT SETTING FOR THIS FEATURE 50 DEFAULT SETTING FOR THIS FEATURE 06 Set Length 2 124 Magellan 1100i Interleaved 2 of 5 Interleaved 2 of 5 continued Interleaved 2 of 5 Stitching Enables disables stitching for Interleaved 2 of 5 labels When parts of an Interleaved 2 of 5 bar code are presented to the scanner with this feature enabled the barcode parts will be assembled by the scanner s software and the data will be decoded if all barcode proofing requirements are met 7 Only functions when Fixed Length Decoding is enabled NOTE PROGRAMMING BARCODE Disable Interleaved 2 of 5 Stitching DEFAULT Product Reference Guide 125 Symbologies Interleaved 2 of 5 continued Minimum Reads This feature specifies the minimum number of c
106. up the Found New Hardware Wizard Select Install from a list and click on Next 2 Click on Include this location in the search and enter the path where the file DLS EUG CDC ACM inf file is stored Click on Next 3 Ifa message appears that says the software has not passed Windows logo testing press Continue anyway 4 Click on Finish 5 Once the install is complete reboot the PC 60 Magellan 1100i Chapter 4 Data Editing CG CO O Data Editing Overview It is not recommended to use these features with IBM interfaces CAUTION When a barcode is scanned additional information can be sent to the host computer along with the barcode data This combination of barcode data and supplementary user defined data is called a message string The features in this chapter can be used to build specific user defined data into a message string There are several types of selectable data characters that can be sent before and after scanned data You can specify if they should be sent with all symbologies or only with specific symbolo gies Figure 4 1 shows the available elements you can add to a message string Figure 4 1 Breakdown of a Message String Label ID Transmission Enable this option to transmit the Label ID you configure for the scanned symbology Tua OR Prefix Label ID AIM ID Bar Code Data Label ID Suffix
107. ys include an industry standard label identifier for ALL symbology types see the previous feature AIM ID The Label ID is a customizable code of up to three ASCII characters each of which are 00 7F followed by a control character 00 01 This control character when set to zero does nothing When set to one it appends the symbology s AIM ID to the Label ID When the control character is set to 01 for UPC A and UPC E it expands the label to EAN 13 and thus follows the EAN 13 Label ID settings NOTE To configure a Label ID 1 Scan the START barcode 2 Select Label ID position as either BEFORE or AFTER by scanning the appropriate bar code 3 Scan a barcode to select the symbology for which you wish to configure a custom Label ID 4 Determine the desired character s you may choose up to three which will represent the Label ID for the selected symbology Next turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For example if you wish to select an equal sign as a Label ID the chart indi cates its associated hex characters as 3D 5 Turn to Appendix C Alpha Numeric Pad and scan the barcodes representing the hex charac ters determined in the previous step For example to make an equal sign scan 3 and D followed by O six times Since this is a three character buffer 00 is scanned for char acter two 0

Download Pdf Manuals

image

Related Search

Related Contents

Toshiba wx2200  fairing mount two-inch oil temperature gauge - Harley  TFG-160D  Valcom V-2995-W door intercom system  Plantronics WH110/A  Sencor SWK 1756RD electrical kettle  Origin Storage DVD-RW kit SF  MZ-RH1  Breville BDC600XL Coffeemaker User Manual  Auxiliary Control Interface Protocol Definition for VideoBlox Rev. III  

Copyright © All rights reserved.
Failed to retrieve file