1. 13 Fixture Setllngs aaa ae aa pt a aa a a e a GG P Ed nin HERUM RO E i PEE FO GN 13 Lamp Settings een BIDA APAN BAG DATA AD 14 Eo ee A a 15 AN AH 15 E 16 Fixture Reset Ba tiia tit e cal aa a a n IH E bis 16 Special FUNCUONS D 17 Offset Mode eii ta aia d da Ca e daia et aia nn A iain BANANA 18 Entering Offset Mode ee di Ege n Aaa ot AD Ap in bobbie 18 DMX Values iere Aaaa Fen E e EC n d a oa da a d aa dau du d 19 ore II e mL 19 Mod 2 Advanced eot aite itt RA GAAN i Re 20 5 Technical Informati ON d a cina d GEAR RARE 21 General Maintenance uh ien cete aee t aet dnd eth dee 21 Dust Screen Cleaning i3 e caca og e ete e T M et nn Pr ERU RTI 21 Error Messa g68 oco ione a e HE ee tbe t hd ee eph ape CIN ano b eet D ar EET 22 Troubleshooting G ld6 4 caca 2 e d aaa dae 23 Legend 1200E Wash User Manual Rev 3 a Table of Contents 4 Returns Procedure xi ED 24 Glais 5 a 24 Contact Usi RA aceia ea Aa ek Error Bookmark not defined Technical Specifications Aa Wek ai e a a es dt neh d d VN
2. 5 Product RAD RANA 6 SOP 7 AG M 7 AC PIUG Ne el eme AN 7 E 7 fovea eek aaa a a a Dada 7 DIVX Od ES LM boa hie a ae RE Satoh As 7 MOUNUINIG ses ic ceai cae i 8 OrierntatiOri 5 a oi AA AA del E AA s e ees 8 RIGGING 8 Bracket Installation ierra eie ren aaa deir tees PADA iets ee 9 Oeo mc a 9 Lamp Replacement ana nite ha tentia a Perte baron ae a Pena Pone 10 increasing the Lamp S Life uuu ete NA nan arae at ita e ido pto Maan a a 10 4 Operation me 11 Control Panel 11 Home SGIe8h n quuin ure 11 Control Options EA A E 11 E la ata cala aaa aa 12 Programming tere 13 Navigation a 13 DMX Operalion sesiza ee poa
3. To return to the previous screen without changing the current option s value press lt MENU gt The Legend 1200E Wash always operates in standard DMX mode no Slave Auto or ID addressing modes The options in the DMX Operation section set the starting DMX address and the DMX mode as well as show the fixture s DMX configuration To access this section do the following 1 Press lt MENU gt 2 Select DMX Functions 3 Select the corresponding function as indicated below 4 Press lt MENUs to exit once you are done with this section To select the starting DMX address do the following 1 Select DMX Address 2 Select a DMX address 001 512 3 Press lt ENTER gt To select the DMX mode whether Basic 16 channels or Advanced 21 channels do the following 1 Select DMX Channel Mode 2 Select Mode 1 16 Basic or Mode 2 21 Advanced 3 Press lt ENTER gt This option shows the values for all the fixture s DMX functions from the first channel starting address to the last channel 16 for Basic and 21 for Advanced 1 Select View DMX Value 2 Press lt ENTER gt the values will show on the screen 3 Scroll with the jog wheel to see all values 4 Press lt MENUs to exit The options in the Fixture Settings section set the pan and tilt modes as well as the blackout options To access this section do the following 1 Press lt MENU gt 2 Select Fixture Settings 3 Se
4. A V Us e r Manual Un y 1 Edition Notes CHAVET Edition Notes Trademarks Copyright Notice Manual Usage Document Printing Intended Audience The Legend 1200E Wash User Manual Rev 3 covers the description safety precautions installation programming operation and maintenance of the Legend 1200E Wash product Chauvet released this edition of the Legend 1200E Wash User Manual Rev 3 in April 2015 CHAUVETO is a registered trademark of CHAUVET amp Sons Inc d b a CHAUVET or Chauvet The CHAUVET logo in its entirety including the Chauvet name and the dotted triangle and all other trademarks on this manual pertaining to services products or marketing statements are owned or licensed by Chauvet Any other product names logos brands company names and other trademarks featured or referred to within this document are the property of their respective trademark holders Chauvet owns the content of this user manual in its entirety including but not limited to pictures logos trademarks and resources Copyright 2015 Chauvet All rights reserved Electronically published by Chauvet in the United States of America Chauvet authorizes its customers to download and print this manual for professional information purposes only Chauvet expressly prohibits the usage copy storage distribution modification or printing of this manual or its content for any other purpose without its wr
5. Short circuit along the power wires Check total load placed on the electrical circuit Check for a short in the electrical wiring Fixture does not respond to DMX when nearby fixtures on the same universe do Wrong DMX addressing Damaged DMX cables Wrong polarity on the controller Loose DMX cables Faulty DMX interface Faulty Display Main board Check DMX mode and starting DMX address Check DMX cables Check polarity switch settings on the controller Check cable connections Replace the Main board Replace the Main board DMX signal problems D Non DMX cables Bouncing signals Long cable low level signal Too many fixtures Interference from AC wires Use only DMX compatible cables Install terminator as suggested Install an optically coupled DMX splitter right after the fixture with the strong signal Install an optically coupled DMX splitter after unit 32 or before Keep DMX cables separated from power cables or fluorescent black lights If you still experience technical problems after trying the above solutions contact Chauvet Technical Support Legend 1200E Wash User Manual Rev 3 23 Technical Information CHAUVET 24 Returns Procedure E E Claims The user must send the merchandise prepaid in the original box and with its original packing and accessories Chauvet will not issue call tags Call Chauvet and request a Return Merchandise Authorization Number
6. RMA before shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return The user must clearly label the package with a Return Merchandise Authorization Number RMA Chauvet will refuse any product returned without an RMA DO NOT write the RMA directly on the box Instead write it on a properly affixed label Once you receive the RMA please include the following information on a piece of paper inside the box Your name Your address Your phone number The RMA A brief description of the problem Be sure to pack the fixture properly Any shipping damage resulting from inadequate packaging will be the customer s responsibility As a suggestion proper UPS packing or double boxing is always a safe method to use Chauvet reserves the right to use its own discretion to repair or replace returned product s The carrier is responsible for any damage incurred during shipping to this product or any part that shipped with it Therefore if the received merchandise appears to have damages caused during shipping the customer must submit the damage report and any related claims with the carrier not Chauvet The customer must submit the report upon reception of the damaged merchandise Failure to do so in a timely manner may invalidate the customer s claim with the carrier For other issues such as missing components or parts damage not related to shipping or co
7. 176 0 1840 192 0 208 0 224 0 232 0 248 0 Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro 13 Macro 14 Macro 15 Macro 16 Macro 17 Macro 18 Macro 19 Macro 20 Macro 21 Macro 22 Macro 23 Macro 24 Macro 25 Macro 26 Macro 27 11 Cyan 000 U 255 0 100 12 Magenta 000 U 255 0 100 13 Yellow 000 U 255 0 100 14 15 3200 K CTO Filter Filters Speed 000 U 000 U 255 255 0 100 0 100 16 Zoom 000 0 008 U 007 255 No Function 0 100 17 20 Preset Color 000 U 022 0 043 U 064 086 107 U 128 0 1490 1710 192 0 2130 234 0 021 042 063 085 106 127 148 170 191 212 233 255 Open white Color 1 Color 2 Color 3 Color 4 Color 5 Color 6 Color 7 Color 8 Color 9 Color 10 Color 11 Pan Tilt Macro Range Function 000 U 000 070 0 080 0 090 0 100 0 1100 130 0 1400 150 0 160 U 170 0 180 0 190 U 200 U 2100 2300 2400 0 100 No function Pan tilt blackout enable Pan tilt blackout disable Color blackout enable Color blackout disable No function Lamp On Pan tilt reset Color reset No function Shutter reset Zoom reset No function Reset all No function Lamp off No function Legend 1200E Wash User Manual Rev 3 CHAUVET Technical Information 5 Technical Inform
8. 2 Motor Cyan Dichroic Flag Magenta Dichroic Flag Motor Yellow Dichroic Flag 3200 K Filter Dichroic Flag Zoom Motor 18 The Offset Mode provides fine adjustments for the home position of all the moving parts in the optical path as well as the pan and tilt movements The home position is where the moving parts go when you reset them In their corresponding home position the moving parts should not show any border or reduce the light output It they do use the Offset Mode to fine adjust them Press MENU to enter the regular Menu Mode Press lt ENTER gt for more than three seconds to enter the Offset Mode the Offset Mode menu will show Press lt MENUs to exit once you are done with offset adjustments Select Pan and press lt ENTER gt a pop up window will open a Select the new value 128 127 b Accept the new value Select Tilt and press lt ENTER gt a pop up window will open a Select the new value 128 127 b Accept the new value Select Shutter and press ENTER pop up window will open a Select the new value 0 255 b Accept the new value Select Color 1 and press lt ENTER gt a pop up window will open a Select the new value 128 127 b Accept the new value Select Color 2 and press lt ENTER gt a pop up window will open a Select the new value 128 127 b Accept the new value Select Cyan and press lt ENTER gt a pop up window will open a Select the new
9. 9 Use the adjustment screws marked B in the diagram to position the lamp in the center of the reflector to obtain the best output 5 e Lamp Replacement Diagram ur FastFit Socket Positions 10 Increasing the Lamp s Life Unlocked NEVER turn the fixture s power off while the lamp is striking as this can damage the lamp permanently ALWAYS turn the lamp off by using the DMX controller or the fixture s control panel Then wait at least five minutes before switching off the fixture This will keep the fans running to extract any remaining heat from the fixture s head ALWAYS wait 15 minutes to turn the lamp back on DO NOT touch the lamp without wearing gloves to avoid leaving grease on the bulb or on the contacts that could reduce the lamp s life ALWAYS change the lamp when it has reached its recommended lifespan to avoid the risk of lamp explosion Legend 1200E Wash User Manual Rev 3 Operation CHAUVET 4 Operation Control Panel Button Function Description lt MENU gt Exits from the current menu or function se de ro lt JOG WHEEL gt Navigates upwards through the menu list and increases the numeric value when in a function Jog wheel ENTER button Control Panel Diagram MENU button Home Screen Upon power up the LCD will show the Legend logo and the fixture s identification After completing the power up tests the LCD will show the DMX address the DMX mode
10. Manual Rev 3 CHAUVET Technical Information Troubleshooting Guide Symptom Fixture does not power up Cause s No power on outlet Blown fuse Bad power cord plug Bad power switch Bad power supply Bad main controller Action s Repair outlet problem or use another outlet Replace blown fuse with same type and rating fuse Repair or replace power cord plug Replace power switch Replace power supply Replace main controller Fixture powers up but lamp does not ignite State Power On parameter set to NO Lamp temperature problems Lamp problems Change parameter to YES Check error messages and follow instructions Check error messages and follow instructions Lamp ignited but has low intensity color temperature Dimmer not at full output Lamp still cold CTC or CMY filter interfering Defective or old lamp Misaligned lamp Defective lamp wires or socket Defective ballast Adjust dimmer value Wait for lamp to come up with full output temperature Set color wheel or filter to home position Replace lamp Realign lamp Repair change wiring or socket Replace ballast Lamp flickers or turns off by itself Defective or old lamp Temperature problems Defective lamp wires or socket Defective ballast Replace lamp Check error messages and follow instructions Repair change wiring or socket Replace ballast Circuit breaker fuse keeps tripping blowing Excessive circuit load
11. When done with the test press lt MENU gt the fixture will go back to DMX mode and all the manually entered values will become 000 The options in the Fixture Information section control the fixture usage timers and show the firmware version To access this section do the following 1 Press lt MENU gt 2 Select Fixture Information 3 Select the corresponding function as indicated below 4 Press MENU to exit once you are done with this section This option shows the time the fixture has been in operation 1 Select Fixture use time 2 Press lt ENTER gt The fixture will show the accumulated time of operation The Fixture Use Time is not resettable This option allows the operator see the fixture and lamp usage timers as well to reset the lamp usage timer after changing the lamp 1 Select Lamp On Time the accumulated lamp usage time will show 2 Select Exit or Reset Time do this only after changing the lamp 3 Press lt ENTER gt This option shows the installed firmware version for each of its various microcontrollers 1 Select Firmware Version 2 Press lt ENTER gt The options in the Fixture Reset section control the resetting of the various functions of this fixture To access this section do the following 1 Press lt MENU gt 2 Select Reset Function 3 Select the corresponding function as indicated below 4 Press MENU to exit once you are done with this section This option resets
12. and the fixture s temperature along with the warning sign if the tests have detected an error DMX Address Error Indicator BEBE ee DMX Address 001 4 MEET EE PII LLLI 21 Ch Te mp 9ooo a eanuuuunuuum enunuanuuuauuae DMX Mode Fixture s temperature When the warning sign shows press ENTER to read the corresponding error message see Error Messages in the Technical Information chapter Press lt ENTER gt while looking at an error messages to clear it Control Options You can set the Legend 1200E Wash s start address in the 001 512 DMX range This allows for the control of to 32 fixtures in the 16 channel DMX Mode 1 and up to 24 fixtures in the 21 channel DMX Mode 2 Legend 1200E Wash User Manual Rev 3 11 Operation Menu Map Main Menu Level 2 Level 3 Level 4 Level DMX Address 1 512 Mode 1 16 DMX Channel Mode N A Mode 2 21 DMX Functions View DMX Value N A WDMX Setting Active Requires optional Retransmit No Yes W DMX card Reset Memory Pan Inverse Tilt Inverse Fixture Settings Moving Bl o Color Change On Off On Off State Power On Off Via DMX L Setti On if DMX On No Yes N A amp Settings p g Off if DMX Off Cooling Mode High Auto Ignition Dela x 0 255 Low Power Delay Display Inverse E 4 No Yes 2 Back Light Auto Off Display Settings N A B
13. move to their home positions this movement may be very small The Special Functions section comprises the maintenance timer options and the factory default option To access this section do the following 1 Press lt MENU gt Select Special Functions 3 Select the corresponding function as indicated below Press lt MENUs gt to exit once you are done with this section EN This fixture has a built in timer to remind the operator that is time for the fixture s routine maintenance When the preset time elapses the warning icon shows on the LCD 1 Select Fixture Maintenance 2 To change the maintenance interval timer a Select Interval b Select the new interval in hours c Press lt MENU gt 3 To reset the remaining time counter a Select Remain Time b Select Reset Time reset the timer or Exit exit without resetting c Press lt MENU gt If you want to default the fixture to its factory configuration follow the steps bellow 1 Select Factory Settings 3 Select Yes default fixture or No exit without defaulting 4 Press lt ENTER gt The above operation will default all the fixture s parameters to their original factory configuration values Defaulting the fixture does not affect the home position settings Legend 1200E Wash User Manual Rev 3 17 Operation Offset Mode Entering Offset Mode Pan Motor Tilt M otor Shutter M otor Color 1 Motor Color
14. one or more fans refrain from spinning them using compressed air The Legend 1200E Wash fixture uses multiple fans To prevent dust buildup on the components of the optic path each of the fans on the forward section of the moving head have a dust screen as shown in the diagram below Fan Housing Top Dust Screen Housing Side To access the dust screens remove the bottom and top housings of the moving head at which point you will have be able to remove the housing sides Once you have cleaned the dust screens reverse the process to replace them Despite having dust screens the fixture still needs regular cleaning of its lenses color wheels and the other components in the optical path Legend 1200E Wash User Manual Rev 3 21 Technical Information Error Messages Message Lamp Startup Fail Cause s The lamp has not started after being struck Action s Check lamp Check lamp socket and wiring Check ballast and igniter Temperature Sense Fail There is no communication with temperature sensor Check sensor wiring Check sensor integrity Check control board Lamp Hot Protection Fixture temperature is higher than 105 C Check fans lamp was switched to low power for safety Check fan wiring Clean vents Lamp Hot Power Off Fixture temperature is 110 C or higher Check fans lamp was switched to off for safety Check fan wiring Clean vents Maintenance Fixture Fixture Maintenanc
15. value 0 255 b Accept the new value Select Magenta and press lt ENTER gt a pop up window will open a Select the new value 0 255 b Accept the new value Select Yellow Filter and press lt ENTER gt a pop up window will open a Select the new value 0 255 b Accept the new value Select 3200 K Filter and press ENTER a pop up window will open a Select the new value 0 255 b Accept the new value Select Zoom and press lt ENTER gt a Select the new value 0 255 b Accept the new value Legend 1200E Wash User Manual Rev 3 Operation DMX Values Mode 1 Basic Ch 4 Function Pan Value 000 0 255 Percent Setting 0 540 Pan Fine 000 U 255 0 100 Ch 10 Function Cyan Magenta Value 000 U 000 U 255 255 Percent Setting 0 100 0 100 Tilt 000 U 255 0 270 Tilt Fine 000 U 255 0 100 12 13 Yellow 3200 K Filter 000 0 000 U 255 255 0 100 0 100 Pan Tilt Speed 000 0 255 Fast Slow D O B D N Dimmer 000 U 255 0 100 Shutter 000 U 0160 132 0 1680 204 0 2400 248 0 015 131 167 203 239 247 255 Slow Fast Slow open Fast close Fast open Slow close Slow open Slow close Random strobe Open Color 1 000 U 008 U 016 U 024 U 032 0 040 0 048 056 U 064 0 128 0 190 0 192 0 007 015 023 031 039 047 055 0
16. website for contact details Legend 1200E Wash User Manual Rev 3
17. 200E Wash on the floor or any other firm horizontal surface Chauvet recommends following the general guidelines below when mounting the Legend 1200E Wash When selecting an installation location consider ease of access to the fixture for operation programming adjustments and routine maintenance Never mount the fixture in places where rain high humidity extreme temperature changes or restricted ventilation may affect it Make sure that the location where you are mounting the fixture can support its weight Please see the Technical Specifications section of this manual for the weight requirement of this fixture or standing as indicated in the diagram below Doing otherwise may cause damage to the fixture and void its warranty Standing position Only mount this fixture where the base is horizontal position either hanging Hanging Product Mounting Bi m Diagram Standing position Safety cable Safety Cable Installation Diagram Omega brackets with clamps 8 Legend 1200E Wash User Manual Rev 3 Setup CHAUVET Bracket Installation You can mount the included brackets on either side of the mounting plate This allows for positioning the fixture s base in the best possible orientation to access the control panel and the fuses Control Panel a ole a m Bracket Mounting 59 CD Diagram T 16 2 Location 1 e e PLTTETETETEEE
18. 63 127 189 191 255 Dark Blue Pink Light Yellow Light Green Light Blue Magenta 5600 K Split Colors CCW rotation fast slow Stop CW rotation slow fast Preset Color 000 U 022 U 043 U 064 U 086 U 1070 128 0 149 0 171 0 192 0 2130 234 0 021 042 063 085 106 127 148 170 191 212 233 255 Open white Color 1 Color 2 Color 3 Color 4 Color 5 Color 6 Color 7 Color 8 Color 9 Color 10 Color 11 Zoom 000 U 008 U 007 255 No Function 0 0 100 Color 2 000 U 008 U 0160 024 0 032 0 040 0 048 0 056 0 064 0 128 0 190 0 194 0 007 015 023 031 039 047 055 063 127 189 193 255 Open white Red Blue Pink Green Yellow Orange UV Purple Split Colors CCW rotation fast slow Stop CW rotation slow fast Legend 1200E Wash User Manual Rev 3 Function 000 U 070 U 080 U 090 U 100 U 1100 130 U 140 U 150 U 160 U 170 0 1800 1900 200 0 2100 230 0 240 0 069 079 089 099 109 129 139 149 159 169 179 189 199 209 229 239 255 No function Pan tilt blackout enable Pan tilt blackout disable Color blackout enable Color blackout disable No function Lamp On Pan tilt reset Color reset No function Shutter reset Zoom reset No function Reset all No function Lamp off No function 19 Operation A A CHAUVET Mode 2 Advanced Ch Functi
19. E 25 b Legend 1200E Wash User Manual Rev 3 Before You Begin 1 Before You Begin What is Included Unpacking Instructions Typographic Conventions Icon Meaning E One Legend 1200E Wash 2 x omega brackets with hanging trigger clamps Warranty Card Quick Reference Guide This product ships in a flight case Immediately upon receiving this product carefully unpack it and check the container in which you received it Make sure that you have received all the parts indicated above and that they are all in good condition If the material inside the container this product and any other accessory included with it appears damaged from shipping or if the container shows signs of mishandling notify the shipper immediately In addition retain the container and all the packing material for inspection See the Claims section in the Technical Information chapter Convention Meaning 1 512 A range of values in the text 50 60 A set of mutually exclusive values in the text 10 A DIP switch to be configured Claims A new term or a section or chapter in this document COLORado UM The name of another publication or manual lt SET gt A button on the fixture s control panel Settings A fixture function or a menu option MENU gt Settings A sequence of menu options 1 10 A range of menu values from which to choose in a menu Yes No A set of two mutually exclusive menu options in a me
20. ES Fa Location 7 Color Wheels The Legend 1200E Wash comes with two color wheels The diagram below shows both wheels and the number assigned to each of the colors on each wheel Light Green Light Blue Light Yellow 3 Color Magenta Pink Wheel 1 T 7 5 600 K Dark Blue Green Yellow E Pink Orange Color Blue Wheel 2 Purple Red Legend 1200E Wash User Manual Rev 3 9 CHAUYET Lamp The Legend 1200E Wash is equipped with a Phillips MSR1200SA SE FastFit lamp This lamp uses a socket that allows for fast and easy lamp changes Follow the procedure Replacement below to safely change the Legend 1200E Wash s lamp Never touch the lamp s envelope glass bulb with your bare hands FastFit lamps do not require touching the lamp s envelope during removal or installation If you touched the lamp s envelope clean it with isopropyl alcohol and wipe it with a lint free cloth before installing it Procedure 1 Turn the fixture off and disconnect it from the power outlet 2 Wait at least 15 minutes for the lamp to cool down 3 Loosen the two screws on the lamp cover marked A in the diagram 4 Lift and rotate the lamp cover as per the diagram to expose the base of the lamp 5 Rotate the ceramic base of the lamp 90 counterclockwise 6 Pull the lamp out by holding it from its base only 7 Insert the new lamp and turn it 90 clockwise 8 Reverse steps 3 and 4
21. ack Light Intensity 1 10 Temperature Unit C F f Auto Test N A Fixture Test N A Manual Test 1 21 000 255 Fixture use time N A Fixture Information Lamp On Time Exit Reset Time N A Firmware Version N A Pan amp Tilt Color Reset Function Shutter amp Dimmer No Yes N A Zoom All E A Fixture Maintenance Interval Remain Time Special Functions N A 12 Factory Settings No Yes Legend 1200E Wash User Manual Rev 3 CHAUVET Operation Programming Navigation Control DMX Operation DM X Address DM X Modes View DM X Values Fixture Settings Pan Reversal Carry out all the programming procedures indicated below from the control panel Refer to the Menu Map page to learn how the menu options relate to each other The Control Panel s liquid crystal display LCD shows the menu items you select When you select a menu function the display will show the available options for the selected function with the first one already highlighted If not at the home screen press lt MENU gt repeatedly until seeing the home screen To enter programming mode from the home screen press lt MENU gt This is the first menu level To highlight functions or options from a screen rotate the jog wheel and stop at the desired function or option To accept the highlighted option press ENTER This may open another screen as per the Menu Map To activate or enable a selected option press lt ENTER gt
22. an be set or modified This fixture can operate at 200 240 VAC 50 60 Hz which eliminates the need for a voltage selection switch The ballast and igniter in the lamp circuit are both of the electronic type 16 or 21 channel DMX moving yoke Pan 540 in 2 8 sec Tilt 270 in 1 6 sec Color wheel 1 Seven colors white red blue pink green yellow orange and UV Split linear colors Rainbow color spin at variable speeds both wheels Color wheel 2 Seven colors white 5 600 K magenta light blue light green light yellow pink and dark blue Split linear colors Rainbow color spin at variable speeds both wheels Variable CTC filter 3 200 6 000 CMY color mixing system with vector speed adjustments Variable shutter Variable 16 bit dimming 0 100 Linear zoom 5 6 20 75 Individual reset of pan tilt color shutter and zoom Remote fixture reset lamp on off vector speed adjustments Built in movement macros with range adjustments Built in color macros 3 pin and 5 pin DMX connections User configurable lamp ignition delay User configurable maintenance reminder Electronic ballast with power factor correction Electronic power supply Automatic pan amp tilt correction Pan amp tilt locks Lamp and fixture use timer Power saver mode W DMX wireless DMX receiver W DMX wireless DMX transmitter Legend 1200E Wash User Manual Rev 3 3 Introduction DMX Channel Summary 16 Channel DMX Mode 21 Ch
23. annel DMX Mode DMX Channel Function 1 Pan 2 Pan fine 3 Tilt 4 Tilt fine 5 Pan tilt speed 6 Dimmer 7 Shutter 8 Color 1 9 Color 2 10 Cyan 11 Magenta 12 Yellow 13 3 200 6 000 K CTO Filter 14 Preset Color 15 Zoom 16 Function DMX Channel Function 1 Pan 2 Pan fine 3 Tilt 4 Tilt fine 5 Pan tilt speed 6 Dimmer 7 Dimmer fine 8 Shutter 9 Color 1 10 Color 2 11 Cyan 12 Magenta 13 Yellow 14 3 200 6000 K CTO 15 CMY CTO Filter Speed 16 Zoom 17 Preset Color 18 Color Macro 19 Pan Tilt Macro 20 Pan Tilt Macro Range 21 Function Legend 1200E Wash User Manual Rev 3 Introduction CHAUVET Product Overview Pan lock Carrying handle 1 of 2 Control panel Legend 1200E Wash User Manual Rev 3 5 Introduction N 4 Product Dimensions 6 Legend 1200E Wash User Manual Rev 3 Setup 3 Setup AC Power A D AC Plug Fuse Replacement DMX Linking DMX Modes The Legend 1200E Wash has an auto ranging power supply that can work with an input voltage range of 200 240 VAC 50 60 Hz Make sure that you are connecting this product to the proper voltage as per the specifications in this guide the product s user manual or on the product s sticker Always connect this product to a protected circuit with an ap
24. ation General Maintenance D A Dust Screen Cleaning D To maintain optimum performance and minimize wear the user should clean the light fixtures frequently Usage and environment are contributing factors in determining the cleaning frequency As a rule the user should clean the fixtures at least twice a month Dust build up reduces light output performance and can cause overheating This can lead to reduced light source life and increased mechanical wear Chauvet recommends cleaning the fixture s external optics with a soft cloth using normal glass cleaning fluid To clean a fixture follow the recommendations below 1 Unplug the fixture from power 2 Wait until the fixture is cold 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents and reachable internal components 4 Clean all external optics and glass surfaces with a mild solution of glass cleaner or isopropyl alcohol and a soft lint free cotton cloth or a lens cleaning tissue 5 Apply the solution directly to the cloth or tissue and drag any dirt or grime to the outside of the lens 6 Gently polish the external glass surfaces until they are free of haze and lint 7 When cleaning units with a movable mirror you should keep the contact with the mirror surface to a minimum to avoid scratching or damaging it Always dry the external optics and glass surfaces carefully after cleaning them If the fixture has
25. e timer expired Proceed with maintenance and reset timer Lamp On Over 700 Hour Lamp change is overdue Change lamp Memory Initial Fail Fan 1 Error Memory chip error found Change main board The indicated fan is not working Fan 2 Error Fan 3 Error Fan 4 Error Fan 5 Error Fan 6 Error Check fan Check fan wiring CPU B Error CPU C Error CPU D Error CPU E Error CPU F Error CPU G Error There is no communication with the indicated auxiliary CPU Check sensors wiring and position Check stepper motor belt and driver board Check control boards Pan Home Sensor Error Pan Encode Error Tilt Home Sensor Error Tilt Encode Error The moving head failed going to home position after power up or fixture reset Check moving head s free movement Check sensors wiring and position Check stepper motor belt and driver board Check the corresponding control board Check main control board Shutter Reset Fail Dimmer Reset Fail Color 1 Reset Fail Color 2 Reset Cyan Reset Fail Magenta Reset Fail Yellow Reset Fail 3200 K Filter Reset Error Frost Reset Fail Zoom Reset Fail 22 The indicated moving part failed going to home position after power up or fixture reset Check part s free movement and integrity Check sensors wiring and position Check stepper motor belt and driver board Check the corresponding control board Check main control board Legend 1200E Wash User
26. ep this manual for future consultation If you sell this product to another user make sure that they also receive this manual Avoid direct eye exposure to the light source while the fixture is on Always disconnect this product from its power source before servicing Lamp explosion hazard Do not open the lamp cover within five minutes of having turned off the fixture The bulb remains hot for a long time after turn off Never touch the bulb barehanded and always handle it by its ceramic base Always connect this product to a grounded circuit to avoid the risk of electrocution Do not touch this product s housing when operating because it may be very hot This product is for indoor use only To prevent risk of fire or shock do not expose this product to rain or moisture CAUTION When transferring product from extreme temperature environments e g cold truck to warm humid ballroom condensation may form on the internal electronics of the product To avoid causing a failure allow product to fully acclimate to the surrounding environment before connecting it to power Make sure there are no flammable materials close to this product while operating When hanging this product always secure it to a fastening device using a safety chain cable not provided Do not carry this fixture from the head use the handles instead Always make sure that you are connecting this product to the proper voltage as per the specifications in th
27. eration To access this section do the following 1 Press lt MENU gt 2 Select Lamp Settings 3 Select the corresponding function as indicated below 4 Press lt MENUs to exit once you are done with this section This option allows turning the lamp off and back on without having to power cycle the fixture 1 Select On Off 2 Select Yes or No 3 Press lt ENTER gt The lamp will turn on or off after pressing ENTER This option allows the lamp to strike immediately Yes or in delayed mode No after powering on the fixture Delaying the lamp strike reduces the inrush current 1 Select State Power On 2 Select Yes immediate or No delayed 3 Press lt ENTER gt The Ignition Delay option on page 15 controls the delay between power on and the lamp striking This option allows the lamp to turn the lamp off and back on from the DMX controller 1 Select Off Via DMX 2 Select Yes or No 3 Press lt ENTER gt When enabled Yes this option turns the lamp on when DMX signal is present 1 Select On if DMX On 2 Select Yes or No 3 Press lt ENTER gt When enabled Yes this option turns the lamp off when DMX signal is absent 1 Select Off if DMX Off 2 Select Yes or No 3 Press ENTER Continues on the next page Legend 1200E Wash User Manual Rev 4 CHAUVET Operation Cooling Mode Ignition Delay Lamp Dousing Display Settings Display Reversal Back Ligh
28. es or No 3 Press lt ENTER gt This option selects the intensity of the LCD backlight 1 Select Back Light Intensity 2 Select 1 10 3 Press lt ENTER gt When enabled Yes this option turns the lamp on when DMX signal is present 1 Select On if DMX On 2 Select 2C Celsius or 2F Fahrenheit 3 Press lt ENTER gt The options in the Lamp Settings section control what tests the fixture will run To access this section do the following 1 Press lt MENU gt 2 Select Fixture Tests 3 Select the corresponding function as indicated below 4 Press lt MENUs to exit once you are done with this section Continues on the next page Legend 1200E Wash User Manual Rev 3 15 Operation Auto Test Manual Test Fixture Information Fixture Operation Timer 16 E Lamp Operation Timer Firmware Version Fixture Reset Pan amp Tilt Continued from previous page This option sets the fixture to run the automatic test 1 Select Auto Test 2 Press lt ENTER gt The fixture will run a single sequence of tests to verify all its functions This option allows the operator to select which tests to run 1 Select Manual Test 2 Select a function from the list 1 21 3 Set the value 000 255 for the selected function the fixture will assume the new function value as if you had used a DMX controller 4 Press lt ENTER gt 5 Repeat steps 2 through 4 for the other functions 6
29. is manual or on the product s sticker Never connect this product to a dimmer pack or rheostat To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power via breaker or by unplugging it Make sure the product s housing or power cable are not cracked crimped or damaged Never disconnect this product by pulling or tugging on the power cable Do not operate this fixture if you see damage on the housing lenses ultraviolet filter or cables have the damaged parts replaced by an authorized technician at once Do not cover the ventilation slots when the fixture is operating to avoid internal overheating Do not aim this fixture toward the Sun Otherwise the lenses could concentrate the solar energy and cause internal overheating The maximum ambient temperature Ta is 104 F 40 C Do not operate this product at a higher temperature In case of a serious operating problem stop using this product immediately La In the unlikely event that your Legend 1200E Wash may require service please contact Chauvet Technical Support Legend 1200E Wash User Manual Rev 3 CHAUVET Introduction 2 Introduction Product Description Features Additional Features Options The Legend 1200E Wash is a moving yoke fixture with a 1200 W short arc discharge lamp It contains an LCD control panel display through which all of the settings c
30. itten consent For better results print this document in color on letter size paper 8 5 x 11 inches double sided If using A4 paper 210 x 297 mm configure your printer to scale the content of this document to A4 paper Any person in charge of installing operating and or maintaining the Legend 1200E Wash should read the guide that shipped with it as well as this manual in their entirety before installing operating or maintaining this product Chauvet believes that the information contained in this manual is accurate in all respects However Chauvet assumes no responsibility for any error or omissions in this document Chauvet reserves the right to revise this document and to make Disclaimer changes from time to time in the content hereof without obligation of Chauvet to notify any person or company of such revision or changes This does not constitute in any way a commitment by Chauvet to make such changes Chauvet may issue a revision of this manual or a new edition of it to incorporate such changes Chauvet If you have any comments about the accuracy of this document or general suggestions regarding how we improve it please call us at 800 762 1084 US callers or 1 Publications Hot 954 929 1115 international callers You can download the latest versions of all Line Chauvet products manuals from www chauvetlighting com Document The Legend 1200E Wash User Manual Rev 3 supersedes all pre
31. lect the corresponding function as indicated below 4 Press MENU to exit once you are done with this section This option reverses the pan angle assignments from 000 0 and 255 540 to 000 540 and 255 0 1 Select Pan Inverse 2 Select Yes reversed assignments or No normal assignments 3 Press lt ENTER gt Continues on the next page Legend 1200E Wash User Manual Rev 3 13 Operation A A CHAUVET 14 Tilt Reversal Blackout During Head Motion Blackout During Color Change Lamp Settings Lamp On Off Immediate or Delayed Lamp Strike E Lamp On Off Remote Control Lamp On When DMX is Present Lamp Off When DMX is Absent Continued from previous page This option reverses the tilt angle assignments from 000 0 and 255 270 to 000 270 and 255 0 1 Select Tilt Inverse 2 Select Yes reversed assignments or No normal assignments 3 Press lt ENTER gt This option enables the blackout feature while the fixture head is moving panning or tilting 1 Select Bl o P T Moving 2 Select Yes blackout enabled or No blackout disabled 3 Press lt ENTER gt This option enables the blackout feature while the fixture is changing colors 1 Select Bl o Color Change 2 Select Yes blackout enabled or No blackout disabled 3 Press lt ENTER gt The Lamp Settings section comprises all the parameters that affect the fixture s lamp and its op
32. me type and rating 3 Screw the fuse holder back in its place and reconnect power You may link the Legend 1200E Wash to a DMX controller using a standard DMX serial connection If using other DMX compatible fixtures with the Legend 1200E Wash it is possible to control them individually with a single DMX controller If you are not familiar with the DMX standard please refer to the DMX Primer document which you can download from the Chauvet Web site The Legend 1200E Wash can operate 16 and 21 channel DMX modes You will find information about these DMX modes in the ntroduction chapter brief description the Operation Instructions chapter configuration details and the DMX Values section individual channel values Legend 1200E Wash User Manual Rev 3 7 Setup N 4 CHAUVET Mounting Before mounting this product read and follow the Safety Notes For our CHAUVET Professional line of mounting clamps go to http trusst com products Orientation Always mount this fixture in any safe position while making sure that there is adequate room around it for ventilation and for the fixture s head to pan and tilt freely Make sure to mount this fixture away from any flammable material as indicated in the Safety Notes section page 2 of this manual Rigging The Legend 1200E Wash comes with two omega brackets and two clamps You will have to use two mounting points per fixture You can also mount the Legend 1
33. ncealed damage the customer must make claims to Chauvet within seven 7 days of receiving the merchandise Legend 1200E Wash User Manual Rev 3 Technical Information Technical Specifications Dimensions and Weight Fixture Only Length Width Height Weight 17 3 in 440mm 22 8 578 31 6 803 79 75 lbs 36 17 kg Fixture in Flight Case Length Width Height Weight 25 in 635 mm 28 in 711 mm 35 in 889 mm 191 05 Ibs 86 22 kg Power Power Supply Type Range Voltage Selection Switching w PF correction 100 240 V 50 60 Hz Auto ranging Parameter 208 V 60 Hz 230 V 50 Hz Consumption 1 604 W 7 86 A 1 584 W 7 15 A Inrush current 3 8A Power Factor 0 92 0 92 Fuse F 15 A 250 V 6x 30 mm fast blow Power 1 0 Input Output Connectors Cable boot N A Cord plugs Bare ended N A Light Source Type Power Quantity HID Lamp short arc 1200 W 1 Socket Lifespan PGJX50 750 50 failure Approved Lamps Phillips Osram GE MSR1200SA SE FastFit 1500 W 60 P50 Lok It Head Movement Pan Range Tilt Range 0 540 0 270 Photometrics Parameter Minimum Zoom 5 m 104 200 Ix Beam angle 5 6 Thermal Maximum External Temp Maximum Surface Temp 104 F 40 C 135 F 57 C DMX 1 0 Connectors Connector Type 3 and 5 pin XLR Sockets Ordering Legend 1200E Wash Flight Case LEGEND1200EWASH Included Warranty Duration Coverage 2 years Limited Legend 1200E Wash User Ma
34. nu ON A unique value to entered or select in a menu Icon Meaning A D This icon indicates critical installation configuration or operation information Failure to comply with this information may render the fixture partially or completely inoperative damage third party equipment or cause harm to the user This icon indicates important installation or configuration information Failure to comply with this information may prevent the fixture from functioning correctly E This icon indicates useful although non critical information The term DMX used throughout this document refers to the USITT DMX512 A transmission protocol Legend 1200E Wash User Manual Rev 3 Before You Begin Safety Notes A D E Personal Safety Mounting and Rigging Power and Wiring Operation Please read the following notes carefully because they include important safety information about the installation usage and maintenance of this product It is important to read all these notes before starting to work with this product There are no user serviceable parts inside this product Any reference to servicing it you may find from now on in this User Manual will only apply to properly Chauvet certified technicians Do not open the housing or attempt any repairs unless you are one of them Please refer to all applicable local codes and regulations for the proper installation of this product Ke
35. nual Rev 3 CSR 1200 SA TAL Fine Adjustment Option Yes Advanced Mode Maximum Zoom 6 600 Ix 20 75 Cooling System Fans Channel Range 16 and 21 Details See Warranty Card 25 User Manual CHAUYET WORLD HEADQUARTERS Chauvet Contact Us General Information Technical Support Address 5200 NW 108th Avenue Voice 954 577 4455 Press 4 Sunrise FL 33351 Fax 954 756 8015 Voice 954 577 4455 Email tech chauvetlighting com Fax 954 929 5560 Toll free 800 762 1084 World Wide Web www chauvetlighting com UNITED KINGDOM AND IRELAND Chauvet Europe Ltd General Information Technical Support Address Unit 1C Email uktech chauvetlighting com Brookhill Road Industrial Estate Pinxton Nottingham UK World Wide Web www chauvetlighting co uk NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 MEXICO Chauvet Mexico General Information Technical Support Address Av Santa Ana 30 Email servicio chauvet com mx Parque Industrial Lerma Lerma Mexico C P 52000 World Wide Web www chauvet com mx Voice 52 728 285 5000 CHAUVET EUROPE Chauvet Europe BVBA General Information Technical Support Address Stokstraat 18 Email Eutech chauvetlighting eu 9770 Kruishoutem Belgium World Wide Web www chauvetlighting eu Voice 32 9 388 93 97 Outside the U S United Kingdom Ireland Mexico or Benelux contact the dealer of record Follow their instructions to request support or to return a product Visit our
36. on Pan Pan Fine Value 000 U 000 U 255 255 Percent Setting 0 540 0 100 Tilt Tilt Fine 000 U 000 U 255 255 0 270 0 100 Pan Tilt Speed Dimmer 000 U 000 U 255 255 Fast Slow 0 100 Ch Function Color Macro Value 000 U 008 U 050 U 092 0 1340 176 U 2180 Percent Setting Open Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 B amp B oO pm Dimmer Fine Shutter 000 U 000 U 0160 1320 1680 2040 2400 248 0 255 015 131 167 203 239 247 255 0 100 Open Slow Fast Slow open Fast close Fast open Slow close Slow open Slow close Random strobe Open Color 1 000 U 008 U 0160 0240 032 0 040 048 U 056 U 064 128 0 190 0 192 007 015 023 031 039 047 055 063 127 189 191 255 Open white Dark Blue Pink Light Yellow Light Green Light Blue Magenta 5600 K Split Colors CCW rotation fast slow Stop CW rotation slow fast 10 Color 2 000 U 008 U 0160 024 0 032 U 0400 0480 056 0 064 0 128 0 1900 194 0 007 015 023 031 039 047 055 063 127 189 193 255 Open white Red Blue Pink Green Yellow Orange UV Purple Split Colors CCW rotation fast slow Stop CW rotation slow fast Pan Tilt Macro 000 U 008 U 0160 024 0 032 0 0400 048 U 056 U 064 U 0720 0800 088 0 096 0 1040 1210 128 0 136 0 144 0 152 0 1600 1680
37. propriate electrical ground to avoid the risk of electrocution or fire To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power via breaker or by unplugging it To determine the power requirements for the Legend 1200E Wash see the label affixed to the side of the fixture Alternatively you may refer to the corresponding specifications chart in the Technical Information chapter of this manual The listed current rating indicates the maximum current draw during normal operation Please refer to the Sizing the Circuit Breakers section in the Appendix chapter of this manual Never connect the Legend 1200E Wash to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch The Legend 1200E Wash has a bare ended power input cord that is hard wired to the base of the fixture Use the table below to wire a plug for the power cord Connection Wire US Wire Europe Screw Color AC Live Black Brown Yellow or Brass AC Neutral White Blue Silver AC Ground Green Yellow Green Yellow Green Make sure to disconnect the fixture s power cord before replacing a blown fuse and always replace it with a fuse of the same type and rating 1 With a Phillips 2 screwdriver unscrew the fuse holder from its housing 2 Remove the blown fuse from its holder and replace it with a good fuse of the exact sa
38. t Automatic Off Back Light Intensity Temperature Unit Fixture Tesis Continued from previous page This option determines the speed of the cooling fans whether always high or automatic 1 Select Cooling Mode 2 Select High or Auto 3 Press lt ENTER gt When the State Power On option is active this setting configures the delay before the lamp strikes after power on 1 Select Ignition Delay 2 Select the ignition delay in seconds 000 to 255 3 Press lt ENTER gt This option decreases the lamp power after the shutters dimmers have been closed for a configurable time to reduce the internal heat accumulation 1 Select Low Power Delay 3 Select the time delay in seconds 000 255 4 Press lt ENTER gt The options in the Display Settings section control the operation of the fixture s LCD To access this section do the following 1 Press lt MENU gt 2 Select Display Settings 3 Select the corresponding function as indicated below 4 Press lt MENUs to exit once you are done with this section This option reverses the LCD orientation 180 to read it upright when the fixture is hanging from a truss 1 Select On Off 2 Select Yes or No 3 Press lt ENTER gt The lamp will turn on or off after pressing lt ENTER gt This option determines whether the LCD backlight will turn off automatically after 30 seconds of control panel inactivity 1 Select Back Light Automatic Off 2 Select Y
39. the pan and tilt of the fixture s head to their corresponding home positions 1 Select Pan amp Tilt 2 Select Yes reset or No exit without resetting 2 Press lt ENTER gt The fixture s head will move to the pan and tilt home positions Continues on the next page Legend 1200E Wash User Manual Rev 3 Operation Color Shutter amp Dimmer Zoom All Special Functions Fixture Maintenance Timers Factory Default D Continued from previous page This option resets the color wheels to their corresponding home positions 1 Select Color 2 Select Yes reset or No exit without resetting 2 Press lt ENTER gt The color wheels will move to their positions this movement may be very small This option resets the shutter and dimmer to their corresponding home positions 1 Select Shutter amp Dimmer 2 Select Yes reset or No exit without resetting 2 Press lt ENTER gt The shutter and dimmer will move to their positions this movement may be very small This option resets the zoom to its corresponding home positions 1 Select Zoom 2 Select Yes reset or No exit without resetting 2 Press lt ENTER gt The zoom motor will move to its home position this movement may be very small This option resets all the motors to their corresponding home positions 1 Select All 2 Select Yes reset or No exit without resetting 2 Press lt ENTER gt All the motors will
40. vious versions of Revision this manual Please discard any older versions of this manual you may have whether in printed or electronic format and replace them with this version Author Editor Manager PD Manager O Desmonteix D Couppe M Graham F Sellers Product at Use on Dimmer X Auto Programs a Glance Outdoor Use Auto ranging Power Supply Sound Activated Replaceable Fuse X X DMX P User Serviceable X Master Slave CMY Oolor Mixing 0 u ux Legend 1200 Wash User Manual Rev 3 A 4 Table of Contents CHAUVET Table of Contents 1c Before You Beglh site ee itae ee Ai a la Ci dat ba ea 1 Whatis Ineludedrs ud ette ses dl an deett ud dot iat all taia 1 Unpacking InStr ctiloris 5 a a Did te olde a ta ar 1 Typographic Conventions usine 1 lcon iMeanlng tr teet al Sta AG tea tenes 1 SatelyNoles Par me ieee fe SAE i ale Ne ze dat del casa ati de EE tei dau eat 2 2 Introduction tr va tans a a Ea n a Aa a aaa aaa 3 Product Descriptions ime ct t a a NA But e e 3 AEE E ils Beate te a ON NA a Mato area Rie edem en dA ia Eat Pat ad 3 Additional Features xin RD e gie dep de de Dog te apa eee ee 3 Oeo PCIE ie s ate Cu tat 3 DMX Channel SUMMA Y nenea nea aa ana aaa aaa aaa aaa amana aaa ana 4 Product Overview oean aaa BANAAG