LED-777 User Manual - Silver Pines Sound & Light
Contents
1. LED 7 7 TABLE OF CONTENTS LINKABLE T I Ma b Velo gt ound Ug Ses STAND ALONE 1 Safety Instructions 2 Technical Specifications 3 Main Function 4 How to control the fixture 5 DMX 512 Configuration 6 DMX 512 Connections 7 Troubleshooting 8 Fixture Cleaning User Manual Please read the instructions carefully before use WARNING 1 Safety Introductions A N Please read the instructions carefully which includes important information about the installation operation and maintenance Please keep this User Manual for future consultation If you sell the fixture to another user be sure that they also receive this instruction booklet Unpack and check carefully there is no transportation damage before using the fixture Before operating ensure that the voltage and frequency of power supply match the power requirements of the fixture It s important to ground the yellow green conductor to earth in order to avoid electric shock Disconnect main power before servicing and maintenance Use safety chain when fixes this fixture Don t handle the fixture by taking its head only but always by taking its base Maximum ambient temperature is Ta 40 C Don t operate it where the temperature is higher than this In the event of serious operating problem stop using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage
2. Use DOWN and UP button to select the 4 channel or 10 Channel mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 10 seconds To go back to the functions without any change press the MENU button again aQ C Pressing ENTER button Use DOWN and UP button to select the SHA or Erid Select the Pressing ENTER button Use DOWN and UP button to select the Gh El or GL 10l Select the Pressing ENTER button Use DOWN and UP button to select the Yes or No 4 Blackout Back to the main functions press the MENU button twice Slave Mode Press the MENU button up to when the SL Mel is shown on the display Pressing ENTER button Use DOWN and UP button to select the Si dor St ick Slave Mode 1and 2 Back to the previous functions without any change press MENU button LED Press the MENU button up to when the is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the ON or OFF mode Once the mode has been selected press ENTER button to setup or automatically return to the main functions without any change after 10 seconds Back to the functions without any change press MENU button again Display Inverse a a Press MENU button until 1 237 is blinking on the display Pressing ENTER button Once the mode has been selected press ENTER button to setup or automatically return to the ma
3. or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Do not connect the device to any dimmer pack Do not touch any wire during operation and there might be a hazard of electric shock To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture The housing must be replaced if they are visibly damaged Do not look directly at the LED light beam while the fixture is on There are no user serviceable parts inside the fixture Do not open the housing or attempt any repairs by yourself In the unlikely event your fixture may require service please contact your nearest dealer 2 Technical Specifications e Power supply Input Voltage AC 100V 240V 50 60Hz e Power consumption 50W e LED Total 392pcs Red 140pcs Green 105pcs Blue 84pcs White 63pcs e Channels 4 Channel Mode a 10 Channel Mode Function Ch2 Ch2 8 Pattern Chase Ch3 Ch9 Pattern Strobe Chase Speed Ch4 Ch10 Dimmer e t can be operated by DMX512 control or can be used as an individual unit without controller e It can be linked together as many as required in master slave mode and perform the great built in programmed lighting shows triggered by music e Please use a 3 pin XLR cable plug when connecting them together e It features different pre programmed chase patterns e Fan cooled e Dimension 319mm x 308mm x 300mm e Weight 5
4. 3KG To select any functions press MENU button until the required one is shown on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will automatically return to the main functions without any change after idling 10 seconds Back to the functions without any change press MENU button The main functions are shown below EHHE i Add H ET DMX512 Address Setting J errar uch Setting 4 Channel chi Hr och Setting 10 Channel z maht Shi a7 Show Mode 0 12 AISE Sh id MENU Sina St pas rL no Blackout Mode No Blackout Lo 2 bL id 1485 Blackout Mode Yes Blackout pr on Ledon LEd H FFF Led off Lf SPH poe Display Normal WSP Display Inversion HEK S Fixture Hours uP Software Version E THOM DMX 512 Address Setting Press the MENU button up to when the is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX 512 address Once the address has been selected press ENTER button to setup or automatically return to the main functions without any change after 10 seconds Back to the previous functions without any change press MENU button mot LIU ID Channel Mode Press the MENU button up to when the Lang is shown on the display Pressing ENTER button and the display will blink
5. ave units DMX start address may have any value but NOT 001 example set the first 3 DIP switches to ON 2 light show Dipswitch 10 off means the unit works normally and on means inversion In order to create a great light show you can set dip switch 10 on on any unit that is linking to the master unit to get contrast movement to the master unit even if you have two units only Dipswitch 10 on the first Master unit is no use for the 2 light show as it is the master unit that operates the light show B Universal DMX controller When using a universal DMX controller to control the chain of units you have to set DMX address by Dip switches from 1 to 9 to make sure all the units will receive its DMX signal Please refer to the following diagram to know how to address your DMX 512 system in the binary code DMX address setting by dip switches 1 Select the channels of DMX controller 2 Dipswitches C vwe 2 e we a o 126 56 Bont show Channel Dip switches setting e Examples a u L ON 412345678910 _ Channel 01 dip on 1 1 5 WOWEGEBEOE ON 123456786910 ir elel elalsluialn Channel 05 dip on 1 3 1 4 5 ON 127345678910 13 JO OOBA SE ON 12345678910 Channel 09 dip on 1 4 14 8 9 Channel 13 dio on 1 3 4 13 C Easy Controller by CA 8 The easy remote control is used only in master slave mode There
6. cannot be branched or split to a Y Pattern 13 130 139 Chase 13 a Pattern 121120 129 Chase 12 cable Inadequate or damaged cables soldered joints or corroded connectors can Pattern 11 110 119 Chase 11 l Pattern 10 100 109 Chase 10 easily distort the signal and shut down the system Beat aclone nes ot cas ce 2 The DMX output and input connectors are pass through to maintain the DMX circuit Pattern 07 070 079 Chase 07 Pattern 068 060 069 Chase 06 when no power IS connected to the fixture Pattern 05 050 059 Chase 05 3 0 119 Pattern 04 040 049 Chase 04 Pattern BaN E pap Geo a 1 errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a Ue i Pattern 01 010 019 Chase 01 Blackout 000 009 Blackout COMMON 240 255 Stand alone At last fixture the DMX cable has to be terminated with a terminator to reduce signal 3 pin XLR plug and plug it in the DMX output of the last fixture 4 Each lighting fixture needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually O amp 1 are equal to 1 5 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 7 Troubleshootino Following are a few common problems that may occur during operation Here are some suggestions for easy trouble
7. in functions without any change after 10 seconds Back to the functions without any change press MENU button again Fixture Hours Press the MENU button up to when the rac is blinking on the display Pressing ENTER button and the display will show the number of working hours of the unit To go back to the functions press the MENU button again Ch UCI Software version Press the MENU button up to when the is blinking on the display Pressing ENTER button and the display will show the version of software of the unit To go back to the functions press the MENU button again 4 How to control the fixture Three ways to operation A Master Slave operation B Universal DMX controller C Easy controller CA 8 A Master Slave operation The fixture will allow you to link the other fixtures together and operate without a controller In Master Slave mode the first fixture will control the others to give an automatic sound activated synchronized light show This function is good when you want an instant show The first fixture have to set in master mode its DMX input cable will have nothing connect it and the other fixtures must be set in slave mode Their DMX input cables connect the last fixture DMX output cable Any fixture can set as a Master or as a Slave In Master Slave mode refer to the DMX settings below Master unit DMX start address MUST be set to 001 First DIP switch ON all other are OFF Sl
8. is a terminator for connect the easy controller inside the fixture By connecting the cable into DMX IN waterproof cable entry gland to the CA 8 terminator of the first fixture you will find that the remote control on the first fixture will control all the other fixtures for Stand by Function and Mode functions Blackout Blackout the unit Function 1 Synchronous Strobe Chase Select 2 Sound Strobe Chase 1 12 3 Two light Strobe Mode Sound Strobe LED OFF fb gab Sarid Controller 6 DMX512 Connections The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels ee Se SS SS pS e e e a 5 DMX512 Configuration DMX512 Configuration Cha a Pattern 25 250 255 Chase 25 00 Pattern 24 240 249 Chase 24 Pattern 23 230 239 Chase 23 Fast Termination reduces signal errors and to avoid signal Pattern 22 220 229 Chase 22 Strobe transmission problems and interference It is always Pattern 21 210 219 Chase 21 advisable to connect a DMX terminal hg A bee Crans is PTTTT Resistance 120 ohm 1 4W between pin2 DMX and Pattern 18 180 189 Chase 18 pin3 DMX of the last fixture Pattern 17 1 70 179 Chase 17 err Pattern 16 160 169 Chase 16 1 Connect the fixture together in a daisy chain by XLR plug cable from the output of the 120 239 Pattern 15 1500 159 Chase 15 l l Chase Pattern 14 140 149 Chase 14 fiO fixture to the input of the next fixture The cable
9. operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics e Clean with soft cloth using normal glass cleaning fluid e Always dry the parts carefully e Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 amp Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements Innovation Quality Performance 11
10. shooting A The fixture does not work no light and the fan does not work 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C Some fixtures don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the fixture Set the proper address D No response to the sound 1 Make sure the fixture does not receive DMX signal 2 Check microphone to see if it is good by tapping the microphone E One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 10 8 Fixture Cleanino The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture