1. to add dial plan configuration page as follow Table 2 5 3 Description of Dial Plan Dial Plan ID The number to identify a dial plan y Dial plan priority rules take effect in accordance with dial plan index size and not Index according to the maximum number received Prefix Match number representative of any number The minimum receiving Number length 0 to 30 If receiving a number equal to the minimum length greater than less than equal to the maximum length the number will be used to continue the call If the maximum length determine the number to receive a Min Length complete will no longer receive a new number and immediately began to number analysis If there are numbers continue to be received the system will give up these numbers Max Length The largest received number length 0 to 30 17 Dinstar Technologies Co Ltd MTG200 User Manual 2 5 4 Dial Timeout Figure 2 5 4 Dial Timeout Dial Timeout ES 0 Default 20 10 10 Total 1 Figure 2 5 5 Dial Timeout Add Dial Timeout Add Dial Timeout ID Description Max Time for Collecting Pretix Time to Reach Min Length atter Prefix Time to Reach Max Length after Min Length OK Reset Cancel NOTE lf Max length equals to Min length in Dial Plan Time to Reach Max Length can be any value Table 2 5 4 Description Dial Timeout Add Dial Time ID The number to identify a dial timeout rule Max Time for Collecting Prefix
2. Ltd MTG200 User Manual 2 2 2 E1 T1 Status Figure 2 2 2 E1 T1 Status E1 T1 Port Status Physical Status v NOTES MN Actived W Disable BB LOS Alarm WRA Alarm BY YAIS Alarm SDN SS7 Signal Alarm E1 T1 Channel Status Port 2 Port 3 Status Frame Sync Idle Signal Busy Fault Disable L blocked R blocked B blocked Color E B z E B Z E E Totalize 2 60 2 0 0 64 0 0 0 NOTES L Blocked Local Blocked R Blocked Remote Blocked B Blocked Both Sides Blocked Table 2 2 2 Description of E1 T1 status 1 LOS Alarm Signal loss alarm this alarm is created when receiving is lost please check the physical connection whether disconnected 2 RAI Alarm Receive remote alarm indication it is a signal transmitted in the outgoing direction when a terminal determines that it has lost the incoming signal Receiving remote alarm indication RAI means the far end equipment over the T1 line has a problem with the signal it is receiving from the upstream equipment 3 AIS Alarm The Alarm Indication Signal AIS failure is declared when an AIS defect is E1 T1 Port Status detected at the input and the AIS defect still exists after the Loss of frame failure which is caused by the unframed nature of the all ones signal is declared The AIS failure is cleared when the Loss Of Frame failure is cleared 4 Disable Means that this E1 T1 is not used 5 ISDN SS7 Signal Alarm Means physical connection is normal si
3. MTG200 Trunk Gateway User Manual V2 0 Dinstar Technologies Co Ltd Address Floor 6 Guoxing Building Changxing Road Nanshan District Shenzhen China 518052 Telephone 86 755 26456664 Fax 86 755 26456659 Email sales dinstar com support dinstar com Website www dinstar com File Name Document Version Firmware Version Date Revised by MTG200 User Manual Revision Records MTG200 User Manual 2 01 01 01 17 04 2012 Technical Support Department MTG200 User Manual Content 1 PRODUCTINTRODUCTIO N d die ad w ki au A kk dat l e A aa 1 I Sas VCE WIC Wy ins l be E QUI Pe nt Si WOL ANE oi e on a ok del 2 LAA NONM Si pi de ok a has daca en icin Seen a ee ka ae a kaka a ba apa 2 L222 A A a taa 3 lka RJA C VAMC SE QU NCS dicta 4 13 POMCUONS AN F JWEN sucio Aisa 4 134 Protocolstandatd Supported da 4 SS A O O 4 1323 Industrial standards Supports dt 5 1 5 4 General hardware Specific id k bo kk 5 2 PARAMETER SETTING 6 2 NAO OMIM ie OO 6 DD SUAS Oe E tk aa ta ya ak ka e e pk a pt ER e e A AE BE RO e e e a e NS e RA 7 US ML TROPA ON ii bain fs ba sad a po a kk a e e e a a a e a alates v Da 8 A AT A ta oi e AB ab ba bat 9 RES OL SO DU a ie ea et at ar a a an e ak e e a ka a a ke An 10 252A PMT GU SAS ads 10 2220 PRE Cal SCACSUCS jis iii tl at end A n e l a l pa aa as ka 11 PPA A ON 12 SN A A sors cat clon a he sages a a ven e ia n fk a iets e a hn ane ban e et sire e ka eta 12 2 AP RI CON A a l taa
4. AS 13 ZA PRE Parameter l italik a ak bk ka a ks a a n a ka pa ot a bak 13 2A ERE AAA et ta pa ata a ya kk eh n te e e kt tn aa IN e kk ya kibo tn 14 ZO WE DAN Group ON NE a Ac 15 ZA BUT PAPAM NE LET ew cous a te a a 15 AA C Ode A w a Mat ns a ak a n ae ak eat a n a a e po a a ka a 16 A DAN W A knn a ik A AS tif a e a A e RR koke ma ao pe e e eee 17 E DAN TAC OU L tot at kan l kte mat al tt kaz ma kt it fk aa n nt kafe be afrik A 18 A E LN P LOL Ozyas tett ot ik a aia at ka EA 18 2 6 SIP CONS kite ti a a ian a tal e e ka e ka a a a e da e e e ak ba n RA 19 ZO II PAL AAA kaa p e ea ak a E Si kan 19 202 A e n en e an a Sa a e a Aeon a n a a e lo a e a e ne at 20 Zid IP GO UP COMM L sa aa ty ja gal el a ke a al a a a n a E pea ba 21 A POUN Ok its tk a tait a e a gu erate ns a n op e n a e a a bs 21 A A AA td eg te A da rae eats es ai ep DA a whe OU e pa ae ema EN ea 23 2 WAG be MAAC te at a a n A I INTER ten a e kt e n ata a tad tik be bou ott ae ke ie 24 291 Management as 24 US AA LO A A A Ft n on io ba fren kase ba 25 MTG200 User Manual D gt DAD AA RE ONLO aight pe e scarica tk a e e an e n a e Oo rues e eet aoe 26 2 9 A V SION IOMA Oee a ala a e ea lao aaa 26 2 9 are Upload a REN FEN PA RE W a dance ED KA A W KO KE AN 26 290 Password Modica om Ns AN 29T ENCERADO 27 SA FAQ A OO 28 3 1 How to get the IP address if I have modified the default IP or forgot it 28 3 2 Equipment physical conne
5. CA am ir z Call from IP Fax Parameter Fax Mode T 38 Fax Tx Gain 0 db Fax Rx Gain 0 db B E on Packet time Redundant frame in packet B Data 4 Fax Control Data Disable Fax Disable DIME Parameter Continuous time signal interval Threshold for detection 27 dbm Table 2 8 1 Description of Voice amp Fax Disconnect Call when no RTP When selected Yes detected call s silence time packet longer than silence timeout that for a long time not received RTP packets then hangup the call Voice Parameter Period without RTP packet The maximum time length of silence PSTN in Gain Incoming PSNT gain Timeout of no Call from PSTN Call timeout of no answer from PSTN 25 Dinstar Technologies Co Ltd MTG200 User Manual answer Call from IP Call timeout of no answer from IP Two modes are provided T 38 Pass through Fax Mode default option is T 38 Fax Parameter Packet time Data packing duration Redundant frame in packet The length of frame in RTP packet Whether to allow the control of voice data Data Fax Control Whether to allow the control of fax The time interval between two different DTMF Parameter Signal interval frequency signals Threshold for detection Frequency detection threshold 2 9 Maintenance 2 9 1 Management Parameter Figure 2 9 1 Management Parameter Management Parameter WEB Configuration WEB Port Telnet Configuration Telnet Port S
6. Generally refer to the time from user dial first digit to harvest in prefix number Time to Reach Min Length after Prefix After receiving prefix number the number has not yet reached the length of the minimum receiving number the length of timeout Time to Reach Max Length after Min Length After receiving number the number has reached the minimum length but not reached the maximum length of the dial timeout 2 5 5 PSTN Profile PSTN profile is used to configure PSTN call number rules and parameter Figure 2 5 6 PSTN Profile PSTN Profile 0 Default 0 101 RFC2 SIPIN Inband Disable 0 0 lt Default gt Not remove No Total 1 Page 1 x 18 Dinstar Technologies Co Ltd MTG200 User Manual Figure 2 5 7 PSTN Profile Add PSTN Profile Add PSTN Profile ID Description Coder Group ID RFC2833 Payload Type DTMF Tx Priority 1st RFC2833 DTMF Tx Priority 2nd SIP INFO DIMF Tx Priority 3rd Inband Overlap Receiving Disable Remove CLI Not remove Play Busy Tone to PSTN Table 2 5 5 Description of Add PSTN Profile The item is 101 by default Peer There are three ways to send DTMF RFC2833 SIP INFO INBAND in 1 2 3 Tx DTMF Option accordance with the priority choice to send the configuration mode Overlap Receiving Not enabled by default only enable this feature Dial plan and Dial timeout have the meaning Remove CLI Default does not remove CLI Play busy tone to PSTN Equipment will play busy t
7. device FEO port connect PC with string and then fill FEO IP address in browser FEO default IP address is 192 168 1 111 It will request customer to input user name and password Default user name and password are admin If customer modified the default IP or forgot the IP that can t enter the configuration page Please connect PC and device serial with the serial line Enter the CLI to view or modify the equipment IP Here IP is set to 172 16 33 60 In addition hold down the RST button to restart the device customer can regain the port s default IP Then enter the IP address of device in the browser address bar Customer will see the following page Figure 2 1 1 Login Interfaces Authentication Required A username and password are being requested by http 172 16 33 60 The site says GoAhead User Name I Password The default user name and password is admin To guarantee the system safety when login for the first time The system will prompt the user to modify the password The interface is shown as below Figure 2 1 2 Modify Password Password Modification Old Password Mew Password Confirm Password Save After inputting the old password input a new password and confirm it by inputting it again Dinstar Technologies Co Ltd 2 2 Status Statistics MTG200 User Manual Users through to traverse the left navigation tree and can complete view edit and configuration device i
8. 0 User Manual Figure 2 7 2 IP Profile Add IP Profile Add IP Profile ID Description Declare RFC2833 in SDP support Early Media Ringback Tone to PSTN Originated from Ringback Tone to IP Originated from Wait for RTP Packet from Peer 1 30 Expanded Type in SDP Table 2 7 1 Description of Add IP Profile IP Profile ID The number to mart the IP Profile Description Description of the PSTN Profile Declare RFC2833 in SDP Support by default Support Early Media Whether support Early Media 183 Ringback Tone to PSTN IP gt PSTN call ring back tone player side if set to local it will play from the originated from equipment and set to IP it will play by the called Ringback Tone to IP originated PSTN gt IP call ring back tone player side if set to local it will play from the from equipment and set to PSTN it will play by the called If set to No will auto send RTP packets during the call if set to Yes will wait Wait for RTP Packet from Peer the RTP packet was sent by the opposite end first then send out RTP packets T 30 Expanded Type in SDP T30 extended types in SDP Huawei ZTE 22 Dinstar Technologies Co Ltd MTG200 User Manual 2 8 Voice Fax Figure 2 8 1 Voice Fax Configuration Voice 4 Fax Configuration Voice Parameter Disconnect call when no RTP packet Gi Yes No Period without RTP packet so O s Gain from PSTN 1d8 Gain to PSTN 2dB Timeout of No Answer Call from PSTN
9. 255 0 CS Management Ethernet Interface Default IP address is 192 168 11 1 default subnet mask is FE1 Dinstar Technologies Co Ltd MTG200 User Manual 1 2 2 Front View Figure 1 2 2 MTG200 Front View OA Will L Ya 7 00 1F D6 70 00 A4 5 N 1002344009108 L SPEED MODEL MTIGZOU ZE DINSTAR RUN ALM RST CONSOLE POWER Table 1 2 2 MTG200 Front View Description Off Power is off Power status indicator Green Power is on Slow blinking Unregister Register indicator Green Fast blinking Register The failure of device Off Normal Yellow indicator Failed RSTO Reset button it is used to restart the device RS232 console port it can be used to debug and configure the device The baud rate is 115200 CONSOLE i ps state of device E1 T1 message normal Flash E1 T1 port connection failed Off Network connection failed Indicating the connection LINK Off E1 T1 port connection normal y Indicating the connection On E1 T1 port connection and sending receiving E1 T1 On Network connection normal and O indicates FEO state of the network and 1 indicates FE1 Indicating the network Off 10Mbps bandwidth bandwidth On 100Mbps bandwidth Dinstar Technologies Co Ltd 1 2 3 RJ 48c Line sequence RJ A8 Pin on T1 E1 PIC RJ A8 Pin Data numbering form Data numbering form COM oo un MTG200 trunk gateway adopts standard RJ 48C interface and impedance value is 120Q Connected end device b
10. IP PROXY platform network environment is relatively poor or not and if so please check Local Network or contact the service provider 5 If go through those steps the device still be in trouble please contact the equipment provider 28 Dinstar Technologies Co Ltd MTG200 User Manual 4 Glossary PRI Primary rate interface DND Do not Disturb FMC Fixed Mobile Convergence SIP Session Initiation Protocol DTMF Dual Tone Multi Frequency USSD Unstructured Supplementary Service Data PSTN Public Switched Telephone Network STUN Simple Traversal of UDP over NAT IVR Interactive Voice Response IMSI International Mobile Subscriber Identification Number IMEI International Mobile Equipment Identity DMZ Demilitarized Zone 29 Dinstar Technologies Co Ltd
11. ction to normal but the network cannot be connected or network communication is NOt normal 0 0 eee eeeeeeseeseeeeeeeeeeeeeeeeeeeeeeeeeseeeeeeeeeeeeeeeeeeeeeeees 28 SO EGUPMENtICAN CTS ESA ADE sor ses DEE 28 AS GLOSSARY ana ab Sa kk al k na ca a daou eka pes aka kosa bade fais kado 29 MTG200 User Manual 1 Product Introduction 1 1 Overview MTG200 is a kind of digital trunk gateway based on embedded operating system and designed for IPPBX and call center MTG200 provides 1 2 4 E1 T1 interfaces for users MTG200 mainly provide E1 T1 interface for small and medium enterprise It supports rich GUI configuration and 120 road traffic and the user setting and maintaining system easily A typical network diagram shows the function of MTG200 as below 5 My SIP TP PSTN LET PRI SS7 PP e MTG200 Trunk Gateway PRI SS7 ELATI SIP gt SIP Server PBX Phone Figure 1 1 1 Application topology Dinstar Technologies Co Ltd MTG200 User Manual 1 2 Equipment Structure 1 2 1 Rear View Figure 1 2 1 MTG200 Rear View A NAVA BH ALA El T1 1200hm ETHERNET QUO FF DC12V1A PORTO PORTI PORT PORTS Table 1 2 1 MTG200 Rear View Description mere Lou n The power interface DC12V 1A PortO Port3 E1 T1 Port There are 4E1 options The Service Ethernet Interface standard 10 100BASE TX Ethernet interfaces Default IP address is 192 168 1 111 default subnet mask is 255 255 255 0 255 255
12. efault is ISDN Telephony numbering plan Calling Party Number Type Six optional types are provided for calling party Unknown International 13 Dinstar Technologies Co Ltd MTG200 User Manual number National number Network special number User number Short code dialing The default option is Unknown Four options available User provider no shield User provide check and Screening Indicator for Displaying send User provide check and having failure Network provide The Caller Number default option is User provider no shield Four options available User provider no shield User provide check and Screening Indicator for No Displaying send User provide check and having failure Network provide The Caller Number default option is User provider no shield Provide six plans Unknown ISDN Telephony numbering plan data numbering plan telegraph numbering plan national standard numbering Called Party Numbering Plan plan private numbering plan The default is ISDN Telephony numbering plan Six optional types are provided for called party Unknown International Called Party Number Type number National number Network special number User number Short code dialing The default option is Unknown Information Transfer Capability Support speech and 3 1khz audio The default option is speech 2 4 2 PRI Trunk Figure 2 4 2 PRI Trunk PRI Trunk runk No Trunk Name ChannelID D Channel El 0
13. ejected User Busy No User Response No Circuit Available Unassigned Number Normal Unspecified and others Statistical information in an intuitive would be reflected on the pie char 11 Dinstar Technologies Co Ltd MTG200 User Manual 2 2 6 SIP Call Statistics Figure 2 2 6 SIP Trunk Call Statistics SIP Trunk Call Statistics a 3cx sip 0 1 elastix sip 0 2 dag sip 0 Refresh Table 2 2 6 Description of SIP Call Statistics SIP Trunk No The number of SIP trunk Trunk Name The name used to describe the PRI trunk Current Calls Number of lines that are being called currently 2 3 Network Figure 2 3 1 Network Configuration Network Configuration Service Ethernet Interface FEO Obtain IP address automatical ly 2 Use the following IP address IP Address 172 16 33 60 subnet Mask 255 255 0 0 Default Gateway 172 16 1 5 PPPoE Account quest Password Service Name Management Ethernet Interface FE1 IP Address 192 168 11 1 Subnet Mask 295 255 255 0 DNS Server Obtain DNS server address automatically DNS Server Primary DNS Server 172 16 1 5 secondary DNS Server 12 Dinstar Technologies Co Ltd MTG200 User Manual Table 2 3 1 Description of Network Configuration Obtain IP address If Selected the MTG will obtain IP address via DHCP automatically Service i Use the following IP If Selected Set a static IP for Service Ethernet Interface Need Etherne
14. erver The port of the Secondary IP address of SNMP Port Sync Interval Time interval of check Time Zone The time zone of local 2 9 2 Data Restore Figure 2 9 2 Data Backup Data Backup Click Backup to download database file to your computer Click Backup to download dialplan file to your computer Click Backup to download exception file to your computer Table 2 9 2 Description of Data Backup database Click the Backup and save the database in your PC dialplan Click the Backup and save the dialplan in your PC exception Click the Backup and save the exception in your PC 25 Dinstar Technologies Co Ltd MTG200 User Manual 2 9 3 Data Restore Figure 2 9 3 Data Restore Data Restore Database EEE Aki Dialplan PENE ke Table 2 9 3 Description of Data Restore Database Click Browse to select the Database file and then click Restore Dialplan Click Browse to select the Dialplan file and then click Restore 2 9 4 Version Information Figure 2 9 4 Version Information Version Information Software 2 01 01 01 2012 02 16 15 52 11 Database 2 00 00 2011 04 13 2231 58 Web 2 01 01 01 2012 02 14 14 39 22 Refresh Here users can view software database and web version information 2 9 5 Firmware Upload Figure 2 9 5 Firmware Upload Firmware Upload Software PEA FAHMI Web POE SAGE NOTE The device mustrestart to take effect after uploading The pr
15. gnaling link has problem 6 Active OK Means that physical connection and signaling link are normal 1 Frame Sync Non voice channel which used as a synchronization channel 2 ldle Means this channel is idle when the channel is enabled and the cable is connected OK 3 Signal Signal channel 4 Busy Means this channel is occupied by voice E1 T1Channel Status 5 Fault The channel is enabled but the cable is not connected 6 Disable Have not use this E1 T1 trunk 7 L blocked Local blocked means that communication can only be initiated from local 8 R blocked Dinstar Technologies Co Ltd MTG200 User Manual Remote blocked means that communication can only be initiated from remote 9 B blocked Both Sides blocked means that the two sides cannot communication 2 2 3 PSTN Trunk Status Figure 2 2 3 PSTN Trunk Status PRI Link Status 0 pril 0 Established 1 prit 1 Established Table 2 2 3 Description of PSTN Trunk Status PRI Trunk No The number of PRI trunk each trunk corresponds to a PRI link Trunk Name Used to identify the name of the trunk E1 T1Port No Indicate the E1 T1 line occupied by the PRI trunk Link Status Indicate whether the PRI link is established 2 2 4 IP Trunk Status Figure 2 2 4 IP Trunk Status SIP Trunk Status 0 3cx sip Access 333 IP Address Established 1 elastix sip Peer IP Address Established 2 dag sip Peer IP Address Established Table 2 2 4 Descri
16. ile IP Profile ID IP Profile ID 20 Dinstar Technologies Co Ltd MTG200 User Manual Incoming SIP Authentication Type There are two modes IP address and Password If user selects password then password will be filled IP to PSTN Call Restriction IP to PSTN side of the limitation on the number of calls the range is 0765535 the default is no limitation If Yes is selected then input limitation number of calls in the edit box appeared PSTN to IP Call Restriction PSTN to IP side of the limitation on the number of calls the range is 065535 the default is no limitation If Yes is selected then input limitation number of calls in the edit box appeared IP to PSTN Time Restriction The default setting is disabled If Enabled is selected then user can edit the start and stop time of prohibition time interval Within this time interval all calls from IP to PSTN are prohibited Calls from PSTN to IP are not limited Detect Trunk Status Detect the status of SIP trunk If select it the equipment will send HEARTBEAT message to peer to make sure the link status is OK Enable SIP Trunk A switch used to enable this SIP trunk or not user can select Yes or No when No is selected this SIP trunk is invalid 2 7 IP Group Config 2 7 1 IP Profile Figure 2 7 1 IP Profile IP Profile E 0 Default Yes Yes Local Local No X Fax Total 1 Page 1 ix Add 21 Dinstar Technologies Co Ltd MTG20
17. lue Time ms 1st 2nd 64 Disable gt Coder Rate kbps Silence Suppression 3rd th HE in AJreoirf 16 Dinstar Technologies Co Ltd MTG200 User Manual Table 2 5 2 Description of Coder Group ID standard for Voice ability total with 8 groups where O is the default group ID Coder Group ID number the codec that equipment supports in the grouping will be displayed in O group Default value cannot be modified Coder Support 3 kinds of voice codec G 711A U G 729 G 723 Payload Type Value Each codec has a unique value refer to RFC3551 Voice Codec packetization time user can define different kinds of coding Packetization Time ms and decoding minimum packetization time Rate kbps Show the voice data flow rate It is disabled by default During talking the bandwidth occupied by voice transmission Silence Suppression will be released automatically for silence party or when talk is paused 2 5 3 Dial Plan Figure 2 5 4 Dial Plan Dial Plan ID Total 1 Page 1 Dial plan used for configuring the receiving number user can configure different prefix number these rules can be divided into 5 groups with a dial plan ID where O is the default setting Notes 1 In order to ensure each rule can take effect long matching numbers prefix rule dial plan index value need smaller 2 Maximum length is 30 this value is the number of the total length and including the prefix length Click Add
18. n the right configuration interface MTG configuration flow chart below Dinstar Technologies Co Ltd wa ulation Login web Configure P Configure PRI SS Trunk Configure PSTN Group Configure SIP Yes Configure P Group Configure Routing Wanip WEN OA Configure l Manipulation MTG200 User Manual 2 2 1 System Information This configuration page includes general information and version information Figure 2 2 1 System Information Web Management System Caution The password current used is a default password please change to a new password for system security System Information Status amp Statistics E1 T1 Status General PSTN Trunk Status MAC Address 00 1F D3 00 02 A3 IP Trunk Status Service Ethernet Mode static PRI Call Statistics Service Ethernet Interface FEO 172 16 33 60 255 255 0 0 172 16 1 5 SIP Call Statistics Management Ethernet Interface FE1 192 168 11 1 255 255 255 0 Network DNS Server 172 16 1 5 PRI Config System Time 2012 3 1 21 54 47 PSTN Group Config System Uptime 9d0h39m0s SIP Config Traffic Statistics Received 62 591 bytes IP Group Config Sent 135 799 bytes Voice 8 Fax Maintenance E Device Model MTG200 Hardware Version PCB 01 DSP Version v7 23 03 01 Web Version 2 01 01 01 Software Version 2 01 01 01 Time Built 2012 02 16 15 52 11 Table 2 2 1 Description of System Information Management Ethernet Interface Dinstar Technologies Co
19. nnected or network communication 1s not normal 1 Make sure the network cable is ok or not can through view the device WAN port or LAN port indicator light to determine the work states of physical connection 2 Makeing sure the connected network devices router switch or hub support 10M 100M adaptive Else connecting the Equipment directly to PC and landing Web then in the local connection Selecting the correct Ethernet Work Mode 3 Check whether there is a LAN port conflict with the existing IP address 4 Login using the serial port in the enable mode to view the correct IP and mask and ping the same segment of the PC or device to see if can pass 3 3 Equipment can t register If the Run LED flashes slowly it means unregistered 1 Check the network connection is working see above section whether the Configuration is Correct 2 Check whether the LAN firewall setting is inappropriate such whether limit the network Communication If it is there are two ways to try to resolve 2 1 Ask network administrators to open limitation with the equipment s network communications it is a special equipment not afraid of virus attacks 2 2 Try to enable the equipment tunnel Through the WEB for Configuration Also please NOTE open the tunnel will impact voice quality Please do not enable the tunnel as far as possible reference WEB Configuration Interface Description section 4 Check whether the Local Network to the S
20. ocess of firmware upload 1 Click Firmware Upload 2 Browse files and choose the loading program Name the file extension Idf 3 Click Upload the upload process will last about 60s and device can automatically restart after uploading The firmware update process don t shut off the power 26 Dinstar Technologies Co Ltd MTG200 User Manual 2 9 6 Password Modification Figure 2 9 6 Password Modification Password Modification Old Password New Password Confirm Password The configuration items are used to change the login password of web configuration 2 9 7 Device Restart Figure 2 9 7 Device Restart Device Restart Click the button below to restart the device Restart Some configuration need to restart device to take effect Click Restart to restart the device 27 Dinstar Technologies Co Ltd MTG200 User Manual 3 FAQ 3 1 How to get the IP address if I have modified the default IP or forgot it Customers have two ways to get the IP address 1 Press the RST button then users can regain default IP Refer to 1 2 1 Front View 2 Connect the CONSOLE with your PC Serial Port The baud rate is 115200 bps The user name is admin password is telnet web login password If password is reset the default password is admin When customers have accessed it and input the command show int to get the IP 3 2 Equipment physical connection to normal but the network cannot be co
21. one from IP to PSTN 2 6 SIP Config 2 6 1 SIP Parameter Figure 2 6 1 SIP Parameter SIP Parameter Local SIP Port Local Domain Save SIP port number and domain name would be allowed to set to different ports and domain name 19 Dinstar Technologies Co Ltd MTG200 User Manual 2 6 2 SIP Trunk Figure 2 6 2 SIP Trunk SIP Trunk Total 0 I Figure 2 6 3 SIP Trunk Add SIP Trunk Add Trunk No Trunk Mame Remote Address Remote Port Local Domain Get Callee from Register to Remote IP Profile ID Incoming SIP Authentication Type IP ta PSTN Calls Restriction PSTN to IP Calls Restriction IP to PSTN Time Restriction Detect Trunk Status 5060 Disable Request line a all 0 Default IP Address Ii a Be EA Disable Yes Enable SIP Trunk Table 2 6 1 Description of Add SIP Trunk Trunk No The range of trunk number is 0 1 Trunk Name Description the trunk Remote Address IP address of remote SIP platform i Remote Port Q 931 port of SIP of remote platform interfacing with this MTG the default is 5060 Received the called number from request domain or To header filed Defined by IETF work group RFC3372 it is a standard used to Local Domain Get Callee from Register to Remote establish remote communication between SIP and ISUP the default is Yes if SIP trunk does not support then set it to No Refer to IP Group Config gt IP Prof
22. priQ 0 Enable 0 ISDN User Side ALERTING E 1 pri 0 Enable 1 ISDN Network Side ALERTING Click Add to add a PRI Trunk If user want to delete or modify a PRI Trunk please select the PRI Trunk user want to do Figure 2 4 3 PRI Trunk Add PRI Trunk Add Trunk Mo Trunk Name Channel ID D Channel E1 T1 Port No Protocol Switch Side User Side Alerting Indication ALERTING PSTN Profile ID 0 Default 14 Dinstar Technologies Co Ltd MTG200 User Manual Table 2 4 2 Description of Add PRI Trunk The number of PRI trunk when user add PRI trunk 07 number will appear in the pull down menu to be selected the number here depends on E1 T1 physical port Trunk No number actually existed in equipment After trunk number is established filling in corresponding port number in E1 T1 Port No so as to assign E1 T1 to designated trunk Each PRI trunk corresponds to a E1 T1 port Description of PRI trunk Channel ID Channel ID of E1 T1 ports this number definition generally starts from 0 Indicate whether E1 T1 supports D channel the default is Yes E1 T1 port number is numbered according to the physical position of E1 T1 it generally E1 T1 Port No starts from 0 Interface type of PRI There are two types are available ISDN and QSIG the default is Protocol GEN Indicate PRI network property of E1 T1 it is divided into User side and Network Switch Side side When PRI loopback is carried out the netwo
23. ption of IP Trunk Status SIP Trunk No The number of SIP trunk Username When SIP trunk is under registered mode change the value in the configuration shown in the account registration If SIP trunk is under non registered mode the value is meaningless as Trunk Mode Peer and Access two modes Register Status Indicate the status of SIP trunk access mode register or unregister when is under peer to peer mode the values is meaningless as Link Status Established and Fault status 10 Dinstar Technologies Co Ltd MTG200 User Manual 2 2 5 PRI Call Statistics Figure 2 2 5 PRI Trunk Call Statistics PRI Trunk Call Statistics YD LI roll j 3121 ral IS kI L Fi L L LA LI Paci r ht EIL m AA EET a Al y 0 pri 0 0 100 1 pri 0 0 100 Release Cause Statistics Normal Call Clearing Call Reject User Busy No User Response Normal Call Cleanng 100 No Circuit Available Unassigned Number Normal Unspecified Others Ca Table 2 2 5 PRI Description of PRI call statistics PRI Trunk No The number of PRI trunk Trunk Name The name used to describe the PRI trunk Current Calls Number of lines that are being called currently Accumulated Calls Total number of calls from running start of system to current time ASR The percent of calls completed in total calls This statistics page show the reasons for release of the call including Normal Call Clearing Call R
24. rk properties of E1 T1 port at both receiving and sending sides must be different Alerting Indication The ring signal include Alerting and Progress 2 5 PSTN Group Config 2 5 1 E1 T1 Parameter Figure 2 5 1 E1 T1 Parameter E1 11 Parameter E1 T1 Clock Source Remote mw E 0 El A LAW CRC 4 HDB3 short Haul 10DB E 1 El A LAW CRC 4 HDE3 short Haul 10DB 15 Dinstar Technologies Co Ltd MTG200 User Manual Figure 2 5 2 E1 T1 Parameter E1 T1 Parameter Modify Part Na Work Mode PCM Mode Frame Mode Line Code Line Built Out ShortHaul 10DB Short Haul 10 DB Long Haul E1 43DB T1 36DB Cancel NOTE The device must restart to take effect Table 2 5 1 Description of Modify E1 T1 Parameter Work Mode E1 or T1 the default is E1 PCM Mode PCM mode A LAW and Mu LAW the default is A LAW Frame Mode The frame modes of E1 T1 are DF CRC 4 CRC4_ITU the default is CRC 4 the frame kanni modes of T1 are F12 F4 ESF F72 the default is F4 Line Code Line codes of E1 T1 are NRZ CMI AMI HDB3 the default is HDB3 The line codes of T1 moe are NRZ CMI AMI B8ZS the default is B8ZS Line Built Out Cable length E1 lines docking the environment will affect the E1 line signal strength kl signal strength according to DB value to select the long term or short term 2 5 2 Coder Group Figure 2 5 3 Coder Group Coder Group Coder Group ID D default setting Payload Type Packetization Va
25. t address to fill the IP address Subnet Mask and Default Gateway Interface FEO If users approach the net via PPPoE please Select it and fill your PPPoE account and password Management IP address Fill the IP address of FE1 Ethernet ntertace Fill the subnet mask of FE1 Obtain DNS server If selected the MTG will obtain DNS server IP address via DHCP address automatically DNS Server Use the following DNS If selected you need fill Primary DNS server addresses the server addresses secondary DNS Server is optional Ntoe FEO port IP and FE1 port IP should be set in different segments After configure the network address and restart the gateway configuration to take effect 2 4 PRI Config 2 4 1 PRI Parameter Figure 2 4 1 PRI Parameter PRI Parameter Calling Party Numbering Plan ISDN Telephony numbering plan Calling Party Number Type Unknown screening Indicator for Displaying Caller Number User provide no shield screening Indicator for No Displaying Caller Number User provide no shield Called Party Numbering Plan ISONT elephony numbering plan Called Party Number Type Unknown le Information Transfer Capability Speech jw Reset to default configuration Save Table 2 4 1 Description of PRI Parameter Provide six plans Unknown ISDN Telephony numbering plan data numbering plan telegraph numbering plan national standard numbering Calling Party Numbering Plan plan private numbering plan The d
26. y cross lines sequence 1 3 Functions and Features 1 3 1 Protocol standard supported e Standard SIP PRI protocol e Dynamic Host Configuration Protocol DHCP e Point to Point Protocol over Ethernet PPPoE e Hypertext Transfer Protocol HTTP e Domain Name System DNS e ITU T G 711A Law U Law G 723 1 G 729AB iLBC optional 1 3 2 System Function e Comfort Noise Generation CNG e Voice Activity Detection VAD e Adaptive Dynamic Jitter Buffer DJB e DTMF mode RFC 2833 SIP INFO and INBAND e T 38 Pass Through FAX over IP e HTTP Telnet configuration e Firmware upgrade by TFTP Web Dinstar Technologies Co Ltd MTG200 User Manual No connect No connect 1 3 3 Industrial standards supported e Stationary use environment EN 300 019 Class 3 1 e Storage environment EN 300 019 Class 1 2 e Transportation environment EN 300 019 Class 2 3 e Acoustic noise EN 300 753 e CE EMC directive 2004 108 EC EN55022 2006 A1 2007 e EN61000 3 2 2006 e EN61000 3 3 1995 A1 2001 A2 2005 e EN55024 1998 A1 2001 A2 2003 e Certifications FCC CE 1 3 4 General hardware specification e Power supply 12VDC 1A e Temperature 0 40 C operational 20 70 C storage e Humidity 10 90 no condensation e Max power consumption 15W e Dimension mm 210 150 38 e Net weight 0 75kg Dinstar Technologies Co Ltd MTG200 User Manual MTG200 User Manual 2 Parameter setting 2 1 Login First
27. yslog Configuration syslog Enable server Address Syslog Level send COR Qos Cos Type NTP Configuration NTP Enable Primary NTP Server Address Primary NTP Server Port secondary NTP Server Address secondary NTP Server Port Sync Interval 604800 Time one GMT 8 00 Beijing Singapore Taipei 24 Dinstar Technologies Co Ltd MTG200 User Manual Table 2 9 1 Description of Management Parameter WEB Port Listening port of local WEB service the default is 80 Telnet Port Listening port of local Telnet service the default is 23 Syslog Enable The default is No If select Yes users will set syslog server address and syslog level Server Address Address for saving system log Syslog Level None Debug Notice Warning Error Please choose the file you want to output information level Send CDR Whether send Call Detail Record through syslog Qos Type There are three options none TOS and DS TOS only supports IPv4 NTP Enable Simple Network Management Protocol is enabled or not the default is Yes Primary NTP server The Primary IP address of SNMP management host computer The host computer of Address the IP address will carry out monitoring and management to equipment Primary NTP server The port that managed device provides trap message it is generally alarm message to Port SNMP management host computer the default is 123 Secondary NTP server The Secondary IP address of SNMP Address Secondary NTP s