Home

Manual - Barr Central Home

image

Contents

1. Press any key to advance to the next screen These conventions also appear in this manual Option names messages and commands appear in bold type so you can scan the text for information When instructions tell you to type a command type the command at the DOS prompt or at prompts in the software When instructions tell you to select an option on a menu move the cursor to the option and press Enter a When instructions tell you to select an option value from a list advance through the list by pressing the amp or key on the numeric keypad BARR RJE ol N o o o O z3 lt oO 3 i gt a During software operation messages might display on the screen In the text short messages appear in bold type and long messages appear in a box a File names and directory names appear in uppercase EJ Screen Cues Cues in the bottom right corner of each software screen indicate keystrokes to press or the type of data to enter The cues change for each field as you move around the screen a i o gt o A Lo Any key Read the information on the screen and then press any key on the keyboard Selection t Use the arrows or keys to move around the screen Move to the desired selection and press Enter Type the highlighted character in the option name as a shortcut to select a menu option Choice Use the
2. 2 Enter the form name The form name you assign must match the form name specified in the host JCL for the job that generates the print output In this example the form name is STD2 3 Leave lines per form at the default of 66 which indicates the page size Enter 132 for the print lines per form to indicate that the form contains two pages Leave the lines per form at the default of 6 226 13 2 Edit Forms 4 Press to display the Carriage Control Table screen Carriage Control Table The lines above the cursor show the form line numbers Enter carriage control characters 1 9 A B or C 00000000011111111112222222222333333333344444444445555555555666666666677777777778 12345678901234567890123456789012345678901234567890123456789012345678901234567890 1 Enter character Note that the length of the entry line reflects the value you entered for Print lines per form The entry line wraps to a second line after 80 characters The default Carriage Control Table with a 1 stop in the first position is all that is required 5 When you press the list is updated to reflect the new form definition b oo im 5 Q n 3 a Edit Forms select one Escape CHECKS PERF STD STD2 Selection l gt Example 5 Printing Labels on a Laser Printer This example shows how to switch from printing on continuous feed forms paper for line
3. The message Spooling paused flashes in the lower left corner of the screen to remind you that all spool activity stops while you are using the Files command 2 Use the arrow keys to select a file Then select a command from the menu Ready Files If you see the Ready Files command instead of the Files command the command menu will look like this BARR RJE 413 N A mi 3 N 3 o 3 e 2 i Printer File State Form Class Prty Copies Size Lines Status LPT1 Ready STD 1 415 busy SUSPEND Ready STD 2 0 busy Date Time CHECKS CK501 1 0 1 1998 1 24 97 10 35 PRICES Hold LABELS 2 3 2 4840 1 24 97 10 44 TAX1040 1040 1 5 1 5180 1 24 97 10 35 INVOICES INV99 2 5 8 3262 1 24 97 10 36 Select file using t PgUp PgDn and press Enter to set State to Ready Spooling paused Escape to exit gt Select a file that is on Hold and press Enter to change the state to ready blank If the command menu displays the Ready Files command you cannot use any of the other features described in this section View a File Use the View File command to view a file 1 Select Y to view the selected file The text of the file displays on the screen i j 2 5 Page 1 Line 1 Colum 1 File TAX1040 cS 1 PRT JOB 8000 1236 5 1 500 BARR MSGCLASS A JOB 5684 s tee 8000 1236 CPU SECONDS LINES 1000 PUNCH FORM COPIES S KKK 7 E JOBPARM LINECT
4. 5 Press twice to return to the Operation screen 6 Select the Send Files to LPT1 or Send Files to COM1 command depending on which destination device you selected Enter file names To combine files separate by a plus t To start a new file leave a blank To cancel press Esc Files C BARR REF PRINTER TST 7 Type the file name c barr ref printer tst 8 Review the printer test printout Compare the printed test patterns with the descriptions of how they should print to determine if you properly configured the software for your printer Compare these test results with results from the test described in section D 1 Resolve Print Problems If the BARR RJE test indicates problems check the following printer port settings under Devices and Printers in the Installation Description Then repeat the test 1831 Ja Uld A 1 Select Choose printer type and verify that you selected the correct printer type 2 Select Miscellaneous printer options and set Printer performance optimized to No 3 If characters are being dropped adjust the setting for Printer timing delay under Miscellaneous printer options BARR RJE 503 If you set the printer type to Generic and Printer performance optimized to No in the software the BARR RJE and DOS test results should match N E s o i TE a a 504 D 2 Test the Printer from BARR RJE Spool Header Whe
5. e A i 72 uw N 450 25 3 Operate the PRT Utility Chapter 26 Special Applications This chapter describes these special BARR RJE applications Converting data between the ASCII and EBCDIC character sets during serial port input section 26 1 a Transferring files from PC to PC section 26 2 Packaging BARR RJE inside an application section 26 3 m Assuming the host communication role section 26 4 Ex Converting Data for Serial Port Input The Barr software converts data between the ASCII and EBCDIC character sets when you input jobs from the PC serial ports COM1 to COM4 and direct them to the mainframe reader RD1 To input jobs on a COM port you must enable the COM port as a source device on the Installation Description s Devices and Printers screen Under Assign Devices you can assign sources COM1 to COM4 to any destination including the host reader devices RD1 to RD4 See section 8 4 COM1 COM4 Devices for more information about setting up COM ports as data sources See Chapter 10 for more information about assigning devices Types of Applications You can use ASCII to EBCDIC conversions for these types of applications N z i D 2 2 Po kZ 5 5 a Inputting files from a VAX and sending them to an IBM mainframe Inputting files from a Hewlett Packard minicomputer and sending them to an IBM mainframe a Inputting data every
6. D c lt x B PR2 5 backspaces printer 2 five pages B PR1 D backspaces printer 2 to the beginning of the dataset B PU1 5 backspaces punch 1 five cards 462 A 1 JES2 Remote Commands C Cancel Operators can use the C command to cancel a job or device under their jurisdiction The C command cancels a job on the printer punch or reader or a job awaiting execution When operators use the C command on an output device the command cancels only the active SYSOUT group on that device it does not cancel other SYSOUT datasets for that job To cancel a job on the output queue use the P command Note If the C command does not cancel the job the operator must re enter the command Format Operators can specify a job number or device with the C command C Jnnnn where nnnn is the number of a job to cancel c dev where dev identifies the device to cancel For dev substitute one of the following RDn to cancel reader n PRn to cancel printer n PUn to cancel punch n a 3 Examples o 3 c J545 E 2 53 os a cancels job 545 C PR1 cancels the output currently printing on printer 1 and deletes other SYSOUT datasets for the job that matches the current setup for the printer C RD1 cancels the job on reader 1 BARR RJE 463 D Display The D command displays information about the system a job a device or a set of devices Format The D command fo
7. KAJ installation Steps To install the Barr package follow these general steps 1 Configure the PC Follow the steps in section 6 2 to set up your PC to work with Barr software 2 Install the Barr hardware Before you install the software files install any Barr hardware you purchased Your Barr hardware comes with individual adapter manuals with installation instructions for each adapter 3 Install the Barr software files Follow the steps in section 6 3 to load the Barr software files onto your PC 4 Configure the Barr software Finally enter the configuration settings from the Barr software Installation Description menu The Barr adapter manuals describe how to enter software settings for any communication adapters or option adapters you installed Chapters 7 through 19 of this manual describe how to configure the rest of the software settings EJ Configure the PC The DOS CONFIG SYS and AUTOEXEC BAT files are part of your PC s custom configuration You need to set parameters in these files when you install the Barr software as described in this section If you use an 802 2 LLC host connection make sure the LAN support drivers described in section 1 1 are installed in the appropriate file BARR RJE 37 The CONFIG SYS and AUTOEXEC BAT files are located in the root directory of the disk you use to boot the PC usually C If you need more information about these files see your DOS manual You mu
8. Printer File State Form Class Prty Copies Size Units Status gt LPT1 Ready STD 1 415 busy LPT2 Ready STD 2 0 busy Date Time CHECKS CK501 1 0 1 1998 1 24 97 10 35 PRICES Hold LABELS 2 3 2 4840 1 24 97 10 44 TAX1040 1040 1 5 1 5180 1 24 97 10 35 INVOICES INV99 2 5 8 3262 1 24 97 10 36 Checking spool files Please wait BARR RJE checks for files copied into the print spool and updates the Print Spool screen with any new files as shown on the next screen Printer File State Form Class Prty Copies Size Units Status gt LPT1 Ready STD 1 415 busy LPT2 Ready STD 2 0 busy Date Time CHECKS CK501 1 0 I 1998 1 24 97 10 35 PRICES Hold LABELS 2 3 2 4840 1 24 97 10 44 TAX1040 1040 1 5 1 5180 1 24 97 10 35 INVOICES INV99 2 5 8 3262 1 24 97 10 36 DOSCOPY Z 5709 1 24 97 8 56 Printers Sort t PgUp Help Files Check Spool PgDn Escape Restore EY Restore Command If you specify a retain directory on the Print Spool Description screen you can reprint files that have been deleted from the spool directory Files are automatically deleted from the spool directory after they print or when you use the Delete command Use the Restore command to restore a file from the retain directory to the print spool Then print the file with the normal spooling commands The Restore command lets you manage files in the retain directory You can view mark sort select and delete files 420 24
9. Conditional new page at end of file Yes Make all files have an even number of pages No Enable VFU download into printer No Printer timing delay 0 Audible alarm on printer error No Test for D P I printer power off No Display count of lines or pages Lines Forms overlay directory Choice This screen shows the options you would see if you selected D P I as the printer type 56 8 3 LPT1 LPT3 Devices Printer performance optimized Choose whether BARR RJE should optimize printer performance by converting data as it is sent to the printer Yes Default Printer performance is improved by changing the data as follows Blank lines are converted to line feeds LF a If the printer has Direct Access Vertical Forms Unit DAVFU support the hardware skip to VFU channel commands are used to perform high speed skipping of blank lines DAVFU is a Dataproducts convention for specifying vertical forms control co i oO S o D a 9 Ss es me Ss a a Horizontal tab characters are converted to the required number of blanks to emulate tab settings at eight character intervals No Data is not changed when it is sent to the printer Conditional new page at end of file Choose whether the software should add a form feed FF to the end of a file if needed This option ensures that each file begins at the top of a new page which is helpful when form feeds are miss
10. 2 Press three times to reach the F2 definition line 3 Use the arrow keys to move the cursor to the remote name 4 Change the remote number RMT15 to the number of your remote by typing over it Contact your host systems programmer if you do not know your remote number 5 Press to store the F2 definition 6 Press until you reach the F9 definition line 7 Change the remote number for the F9 key and press to store your changes 8 When you finish editing press to return to the Function Keys screen 9 To verify that you stored the new definitions select Fl to F10 and review your changes on the Function Key Definitions screen BARR RJE 247 Adding a Function Key Definition This example shows you how to define the function key to cancel a job on RJE printer 1 For JES2 this command is C PR1 1 From the Function Keys screen select Alt F1 to F10 to reach the Alt Function Key Definitions screen Alt Function Key Definitions F1 F2 F3 F4 F5 F6 na gt amp x i Oo Le a F7 F8 F9 F0 Reenter last command Reenters last typed command to host may be edited Enter character The description and command entry lines are blank for keys to F9 which have not been defined The key is reserved for the repeat command function discussed in section 14 3 2 Enter the description Ca
11. Assign Devices g 2 gt i i oe SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PU1 SUSPEND SPOOL1 LPT1 Continue Escape Receive mode Options Help Choose from the following options Continue Make another assignment The cursor returns to the assignment area of the screen Escape Return to the Installation Description screen When you finish making assignments select Escape or press the key Receive mode Assign a receive mode to a device The receive mode selections display at the bottom of the screen See section 10 8 for more information about receive modes Options Assign options to a device The Assign Devices Options screen displays See section 10 9 for more information about these options Help Display a help screen that contains hints for using the Assign Devices screen 152 10 2 Assignment Screen ETE Source and Destination Devices Data sources and destinations are relative to the Barr software Data flows into the software from source devices Data flows out of the software to destination devices You can define up to 40 devices in the software The devices you enable display on the Assign Devices screen This section describes the available source and destination devices listed in Table 10 1 Devices you enable from option software are described in gt the corresponding option manual g
12. received produced Space 0 lines CR overprint Space 1 line CR LF Space 2 lines CR LF CR LF 2 Space 3 lines CR LF CR LF CR LF Fa Skip to stop 1 FF to start new page E Skip to stop 2 9 CR LF to advance to line indicated A B C 2 a 490 B 1 Sending ASCII Data EER EBCDIC and ASCII Translation During data translation BARR RJE converts the representation for a symbol in one coding system to the representation for that symbol in the other coding system In many cases an identical symbol exists in both coding systems so translation is straightforward For example the letter A is represented as hexadecimal 41 in ASCII and C1 in EBCDIC In a few cases an identical symbol does not exist in both coding systems but an equivalent character can be substituted For example the EBCDIC logical not symbol is represented by the ASCII circumflex A the alternate representation for this symbol In other cases an equivalent symbol does not exist because all the graphic symbols do not appear in both the ASCII and EBCDIC coding systems In these cases the software substitutes a question mark for the symbols For example the EBCDIC hexadecimal 62 does not have an equivalent representation in ASCII When BARR RJE converts from EBCDIC to ASCII it substitutes an ASCII question mark hexadecimal 3F for hexadecimal 62 Three Translation Tables Translation of Control Codes BARR RJE has three translation tables one
13. trace See line trace Messoj9 translation Process of converting from one coding convention to another BARR RJE 547 transmit To send data from one place to another for reception transparent transmission A variation of binary synchronous com munication that allows transmission of all 256 characters TSR Terminate and Stay Resident turnaround Transmission in the reverse direction that is reversal from send to receive or from receive to send This usually refers to a half duplex communication channel UCS Universal Character Set Some printers such as the IBM 3203 and 3211 require that you load a UCS buffer to match the print train or band installed UNIX An operating system for workstations developed by Bell Laboratories that features multiprogramming in a multi user environment It was originally developed for minicomputers but can now be used on mainframes and microcomputers USSTAB Unformatted System Services Definition Table A mainframe system table that defines character coded commands VAX A super minicomputer made by Digital Equipment Corporation vertical forms control Specification for spacing of lines on print form VGA Video Graphics Array a type of video adapter virtual route pacing VPacing In SNA communications pacing used to control data flow of the application and VTAM VM IBM s Virtual Machine operating system A popular operating system for interactive
14. Mount Forms Select printer PR1 No form Escape PR2 No form Selection tl The name of the assigned form displays next to each printer name The selection No Form indicates that a form has not been assigned 2 Select a printer nan E 2 A list of available forms displays D Mount Forms a m an Select form No form for PR1 CHECKS PERF STD Scroll gt STD2 Selection l gt 3 Select a form Forms vs FCBs If you use one of the automated methods for mounting forms you set Mount forms by to one of the FORMNAME or FCBNAME choices the selection prompt reflects the method for naming forms a If you name forms for the host form name the prompt is Select form for PRI a If you name forms for the host FCB name the prompt is Select FCB for PRI Forms List The forms you defined under Edit Forms display in the selection list To assign a form select a form from the list Use the first selection No Form if you do not want to assign a form 234 13 4 Mount Forms See Mount Forms Examples below for the steps required to assign a form The selection screens displayed are slightly different depending on whether only one RJE printer or more than one RJE printer is defined No Form Selection If you select No form for a printer a form is not assigned and you are retumed to the previous screen A Carriage Control Table will not be defined for f
15. To start a new file leave a blank To cancel press Esc Files JCL DATA N o gt J eej wv amp m i 3 2 5 Example 5 Files from Disks If you need to send files from different disks as one file type only the first file name followed by a plus sign The plus sign tells BARR RJE that more files will be sent as part of the concatenated file BARR RJE delays sending the end of the file so that you can change disks and continue sending files For example to send files from two disks as one job follow these steps Enter file names To combine files separate by a plus To start a new file leave a blank To cancel press Esc Files A FILE1 BARR RJE 341 1 Type the first file name followed by a plus sign and then press to send the file 2 Wait until the disk drive is free The console displays CLOSE A FILE1 and the disk drive light is off 3 Remove the first disk and insert the second disk Enter file names To combine files separate by a plus t To start a new file leave a blank To cancel press Esc Files B FILE2 FILE3 4 Select Send Files and type the names of files to send from the second disk Separate the file names with a plus sign Note Do not enter a plus sign after the last file name Send Modes When you send files to the mainframe by assigning the destinations RD
16. a Length of end of file marker Specify the length of the end of file marker The maximum value is 8 BARR RJE recognizes the end of file marker that it receives from the serial port The default end of file marker is the one byte hexa decimal 1A used by DOS and VAX VMS If you set Input mode to Binary use a four byte end of file marker End of file marker Enter the end of file marker as hexadecimal digits The entry line reflects the length specified by the previous option The default value 1A is the end of file marker used by DOS and VAX VMS Strip leading nulls Choose whether to strip leading nulls from the beginning of files input on the serial port Nulls are sometimes sent by a serial device when you power it on Yes Default Strip leading nulls from files No Do not strip leading nulls BARR RJE 69 Card reader input If you plan to receive data from a card reader select how the end of file will be handled Some card readers generate additional charac ters after the end of file marker which if not discarded would cause BARR RJE to open a new file Your selection depends on how your card reader signals the end of file No Default Data will not be input from a card reader The end of file marker is handled normally Yes Data will be received from a card reader After the end of file marker has been detected all characters are discarded up to and including the next carriage return This is the
17. o 5 a E i a 202 11 4 Screen Border Option Modem Type and Dialing Instructions If you use an internal PC SYNC modem or an external AT or Dataphone 2224B modem BARR RJE can automatically dial the host computer with a phone number you enter in the Barr software If you have a PC SYNC internal modem see your Barr PC SYNC adapter manual for more information EFA Modem Selections 1 From the Installation Description menu select Modem Type and Dialing Instructions ok N a D 3 5 a 2 o 5 N A Modem Type and Dialing Instructions screen displays Modem Type and Dialing Instructions BARR PC SYNC modem Not autodial modem Dataphone 2224B modem AT modem Escape Selection tJ7 2 Select the option that corresponds to your modem BARR PC SYNC modem Select this option if you purchased a Barr PC SYNC modem adapter Your PC SYNC adapter manual describes the screens that display Not autodial modem Select this option if you use an external modem other than an AT or Dataphone 2224B modem Use this selection for the following Modems that require you to manually dial the phone number Modems you can program with the phone number Modems or DSU CSUs on a dedicated line BARR RJE 203 If you did not install a Barr PC SYNC internal modem the software selects this option by default If you have an external m
18. 0 00005 213 Printer FoOrmS s 2 00220nncenenen te 215 Printer Forms Menu 0 00000 ccc eee eee eee eee 215 Edit FOS ona ge olka eve hase 108k Toor sleek Bacon aaa ddan do tionn Sd 216 Edit Forms Menu 0 0 0 ccc cece ce eee eee 217 Format Information 0 0 0 0 cc cece cee eee eee 218 Carriage Control Table 00 0 0 eee eee eee eee 219 Edit Forms EXAMP ES so aE EAEEREN E las deena A ears 221 Using Printer Control Data with Forms 229 Printer Control Data Processing 00 02 eee eee eee 230 Printer Control Data Examples 0020s eee ee eee 230 Mount Forms a dase dcinie ead AA NA 233 Mount Forms Menu 0 0 0 0 eee eee 234 Mount Forms Examples 0 00 c eee eee ee eee 235 Printer Forms Commands Sent to Host 237 Entering Command Strings 2 02 cece eee eee eee 239 Printer Command Examples 000000000 ee eee 240 MVS JES2 Special Forms Printing 0 0 00 241 Function KeyS 00 cece eee eee eee eee 245 Selecting Function Keys 0 cee cece ee eee eee 245 Entering Key Definitions 00000 246 Definition Guidelines 0 00 0 0c cc ccc ee eee eee 246 Changing a Function Key Definition 247 Adding a Function Key Definition 00 248 Using the Repeat Command Function
19. 0 0 0 0 cee eee eee 505 E 3 How File Attributes Are Set 2 0 0 0 e eee eee eee 506 E 4 Field Descriptions 0 0 0 cece eee eee ee eee 509 Appendix F Form Information Sources 0 2050000 513 F 1 Obtaining Form Information 0 004 513 F 2 Using SETUPHDR with Edit Forms 0 515 F 3 Using FCBLOAD with HASP190 0220000 519 F 4 Using Edit Forms with Manual Mount Forms 526 Warranty Information sissies ess sa seco tense eee te eeee ee a 527 GIGS SAY a aa al aa tia alia site wae Ss Ste Sw laa aa ate nl we OE 533 NNN Nal a a a a a ae a ats a ta Sta tata a as 551 xvi Contents _ 5 e 2 o 5 Introduction With BARR RJE software and optional hardware your PC emulates an SNA RJE workstation This chapter describes equipment requirements and lists BARR RJE package contents ERM Equipment Checklist In addition to the items included in the Barr package you need the equipment described in this section PC Requirements PC hardware and software requirements vary depending on your application the environment at your site peak workloads and other considerations At a minimum your PC must have these features a 640 kilobytes of memory m A 386 25 33 or 486 processor 2 000 to 5 000 bytes of storage per page of data you can store 200 to 500 pages of data per megabyte of hard drive capacity
20. D U RMTnnnn displays information about the devices attached to the operator s remote where nnnn is the operator s remote number Information includes the STATUS active inactive or drained the current settings for FORMS and QUEUE and WS work selection criteria D jobname displays a list of all jobs in the system with that job name including jobs not under the operator s jurisdiction Examples D F displays the forms queue for the remote D J244 displays job 244 D J234 J534 displays jobs 234 and 534 D J1 99999 displays all jobs in the system under the operator s jurisdiction D MRO yes sends a yes message to the host computer operator D N Q PPU displays the jobs waiting to print or punch at the operator s remote terminal BARR RJE 465 gt J 3 2 o o 3 3 D 2 z D Q Q PPU displays the number of jobs waiting to print or punch D U LGN displays the VTAM APPLID for JES2 D U RMT4 displays the status of devices at remote 4 D DATA displays information about the job s named DATA JES2 Responses This section describes JES2 responses to frequently issued D commands DU PR1 When you know you are logged in to JES2 and the console is working but nothing is printing you can issue the DU PR1 command Here is a typical response from JES2 DU PR1 10 41 10 HASP603 R122 PR1 10 41 13 HASP603 R122 PR1 STATUS INAC
21. BARR RJE 209 Autodial retries This option specifies the maximum number of times the software tries to make the modem connection if the first attempt is unsuccessful The default value 999 indicates the software will retry the connection indefinitely When the software retries the specified number of times it exits to DOS Starting time Use this option for delayed communications startup unattended operation or dialing after normal business hours to save long distance phone charges Normally you do not need to enter a connection start time If you leave this option blank the Barr software immediately tries to make the connection when it starts If you specify a starting time after startup the Barr software waits until the time indicated to make the connection If the software starts within 8 hours after the specified time the software makes an immediate connection rather than waiting for the next occurrence of the starting time a Fad i E a E v g i i N When you enter a starting time use the 24 hour scheme where 1 a m is 01 00 and 1 p m is 13 00 Verify that the time on your PC is correct use the DOS time command to ensure that the software makes the connection at the specified time CTS delay The Clear To Send CTS delay introduces a delay in milliseconds 1 1000 second before sending data This value must match the setting on the other modem Choose one of these selections 1
22. Carriage Control Table The lines above the cursor show the form line numbers Enter carriage control characters 1 9 A B or C a E ras o a Gr pas 000000000111111111122222222223333333333444444444455555555556666666 123456789012345678901234567890123456789012345678901234567890123456 1 Enter character gt Enter the carriage control characters for the form The line numbers for the form display above the carriage control stop entry line beginning with line 01 Note that the number of lines in the Carriage Control Table equals the number you entered for Print lines per form Because line 01 is the most common location for stop 1 the Carriage Control Table for each form contains a 1 stop on line 01 by default If your file requires stop 1 on a different line you can change the stop location Carriage Control Characters FORTRAN and COBOL programs use the first character of the print line as a carriage control character The action of this carriage control character is defined by the ANSI standard X3 78 1981 level 2A Many programs use only a or a blank as a carriage control character to advance the printer The 1 usually means go to a new page The blank means print the data single spaced and advance to the next line However 220 13 2 Edit Forms forms such as checks and invoices might require additional carriage control stops Carriage control stops and thei
23. Directory of C MISC File Size Date Time File Size Date Time PAYROLL 001 14120 03 26 97 10 39 PAYROLL 002 120 03 26 97 14 51 PAYROLL 004 177917 03 27 97 13 21 PAYROLL 005 180205 03 27 97 10 43 PAYROLL 006 157290 03 27 97 10 02 TAX1040 19 03 26 97 10 36 PRICES 18 03 26 97 10 36 INVOICES 15 03 26 97 10 37 CHECKS 001 156413 03 26 97 11 23 CHECKS 002 120 03 26 97 14 51 CHECKS 003 765 03 28 97 08 31 CHECKS 004 2492 03 28 97 09 14 CHECKS 005 328 03 28 97 11 06 MYLIST 15 03 28 97 11 48 FILEDESC LST 120 03 26 97 14 51 JOELIST 174 03 28 97 11 49 Spool File File Directory DOS Controls View File Quit View file on screen 1 Select View File from the command menu View File Select file from list Enter filename 2 Choose Select file from list N ol N gc a vu Es Cc z lt The cursor moves to the file list portion of the screen BARR RJE 447 Directory of C MISC File Size Date Time File Size Date Time PAYROLL 001 14120 03 26 97 10 39 PAYROLL 002 120 03 26 97 14 51 PAYROLL 004 177917 03 27 97 13 21 PAYROLL 005 180205 03 27 97 10 43 PAYROLL 006 157290 03 27 97 10 02 TAX1040 19 03 26 97 10 36 PRICES 18 03 26 97 10 36 INVOICES 15 03 26 97 10 37 CHECKS 001 156413 03 26 97 11 23 CHECKS 002 120 03 26 97 14 51 CHECKS 003 765 03 28 97 08 31 CHECKS 004 2492 03 28 97 09 14 CHECKS 005 328 03 28 97 11 06 MYLIST 15 03 28 97 11 48 FILEDESC LST 120 03 26 97 14 51 JOELIST 174
24. If the same file name occurs thousands of times additional renaming is performed If extension 999 is reached a 1 is placed at the end of the file name and the extension sequence starts again continuing until 10 999 is reached When 1 is added the sequence numbers start over beginning with 000 For example if the original file name is taxdata a series of files with the same name would be renamed as follows taxdata 001 taxdata 002 taxdata 999 taxdat 1 000 taxdat 1 001 taxdat 1 999 taxdat 2 000 taxdat 2 001 taxdat 2 999 taxda 10 000 taxda 10 001 taxda 10 999 File Name Examples These examples illustrate several of the file naming options Example 1 Use the Job Name as the File Name For easy file identification you might want to use the job name assigned by the mainframe computer as the PC file name especially if the mainframe file name is not meaningful The job name will be extracted from the spool header as explained in the description for the Ending of file name option 1 Select PR2 as the data source 2 Select FILE as the destination The file name screen displays BARR RJE 167 Assign Devices Beginning of file name C JOBS Ending of file name is jobname New file Log Choice 3 Enter the Beginning of file name including the path In this example the path is C JOBS Include a backslash at the end of the path 4 For Ending of file n
25. S start T set device options Z halt Controls or Displays job printer punch job printer punch reader job queue printer punch printer punch job printer punch job printer punch job job printer punch reader job queue printer punch reader printer punch printer punch D gt J 3 2 o 3 3 D Ss 2 7 Each command is described in a separate subsection BARR RJE 459 JES2 Command Types There are two categories of JES2 commands 1 Commands used to display information about the system devices or jobs in the system 2 Commands used to control the JES2 system and operations for the jobs and devices under the operator s jurisdiction JES2 Command Format Enter JES2 commands from a console as follows verb operand1 operand2 where is the JES2 command identification character verb is a single character verb that identifies the action to take operand modifies the verb or command or identifies the job or system facility to act on Use commas to separate operands when you specify more than one operand You can insert blanks anywhere in the command after the initial but they are usually not necessary When you enter JES2 commands on data lines you must begin them with as follows verb operandi operand2 This section shows the commands in the console format CA D c lt JES2 Device Names R
26. When BARR RJE receives compressed output it reverses the process and expands the data into its full length which is called decompression SNA compression and decompression substantially increase the throughput of the communications link The total throughput is greater than the throughput possible with the earlier 2780 and 3780 protocols Data Compaction and Decompaction In many business reports numeric data occurs frequently With data compaction the data sender represents 2 bytes of numeric data as 1 byte The data receiver decompacts the data into 2 bytes Compaction normally increases line throughput by 15 percent Immunity from Communications Errors Cyclical redundancy check CRC greatly reduces the probability of accepting data with communications errors Synchronous communication uses a robust CRC that catches all 1 2 and 3 bit errors in a sequence It appends a 16 bit CRC value to each message Asynchronous com munication does not contain CRC The CRC value is a function of all other bits in the message The message receiver recomputes the CRC value and compares it to the CRC value received If the two CRC values are equal BARR RJE assumes it received the message correctly When the received CRC and recomputed CRC do not agree the message sender sends the data block again Automatic Command Execution You can package BARR RJE into an end user application The software directs the modem to dial the telephone Then it se
27. When you press Enter the Serial Port Source Options screen displays The following section describes the options you must specify Serial Port Source Options When you input data on the serial port the serial port is called a source device This section discusses serial input sample applications error handling and software options n o L a 3 n a S oa Sample Applications Serial input has several applications You can do the following a Send data to a printer Data input on a serial port can be written to a file or sent to a printer attached to a PC parallel port a PC serial port or the LAN Use the Assign Devices screen to specify the destination device Send a job to the host Job control statements can be automatically added to a file input on the COM port The job control statements or JCL form the data into a job to submit to the host You enter the job control statements as a serial port input header from the Printer Control Data screen Section 8 8 describes the special control charac ters required to set up the serial port input header Send a command to the host Data to be input on the serial port can include a command to the host at the beginning of the input file This feature lets you automatically issue a command to the host immedi ately before you send a file to the host The command is sent to the host with the device assignment KEYBOARD COMMAND Any data that
28. When you select a source device on the Assign Devices screen a list of destination choices displays The screen below shows the default destination list The destination choices on your screen include devices you enable and devices the software automatically provides Assign Devices DESTINATION FILE SCREEN NUL SUSPEND LPT1 COMMAND RD1 SPOOL Selection l gt _ A 2 5 i D S o 7 After you choose a destination from the list your selection displays on the Assign Devices screen after the arrow for example PR1 LPT1 FILE The file destination directs files to disk You can route data to a file anywhere within the DOS file system including to a floppy disk hard disk or LAN directory When you select the file destination you are prompted to enter a file name and specify other options See section 10 5 Assigning a File as a Destination for more information The file destination is enabled automatically You cannot remove it from the destination list SCREEN The screen destination directs files to the console portion of the PC screen The most common application is to set CON SCREEN so you can view console messages See section 21 7 for more information about console messages The screen destination is enabled automatically You cannot remove it from the destination list NUL Data sent to NUL is discarded For example if you do not plan to use the console log dev
29. and press Enter Escape to exit Spooling paused 2 Select a printer with the keys A blinking arrow indicates the current printer Select the printer s state field and change the state to Reprint 4 Change the printer s form and class attributes to match the form and class of the file you want to reprint 5 Press Enter 424 24 7 Reprinting Files Page 1 Line 1 Colum 1 File TAX1040 1 PRT JOB 8000 1236 5 1 500 BARR MSGCLASS A JOB 5684 k 8000 1236 CPU SECONDS LINES 1000 PUNCH FORM COPIES KKK JOBPARM LINECT 0 2 EXEC PGM IEBGENER 3 SYSIN DD DUMMY 4 SYSPRINT DD SYSOUT A 5 SYSUTL DD 6 SYSUT2 DD SYSOUT A DCB BLKSIZE 80 RECFM FA BSsSsssssssssssssssssssssssssss End of Page s s sssssssssssssss ss PgUp Previous Page Scroll Page ti gt Find Text Disable Printer PgDn Next Page Go to Page Eject Page Print Test Page Start Print Block Print EBCDIC ASCII Escape The text of the selected file displays on the screen 6 Use reprint commands to position the file for reprinting and start printing it on the selected printer Reprint Commands Use the reprint commands to select the starting point for the reprint operation In some cases the software automatically records where it stopped printing so you might not have to manually reposition a file After a file starts printing if you put the file on hold or the sof
30. 1E 1E RS 3E 6E gt 5E 5F A 7E Al 9E 1E RS BE 6E gt DE 5F A FE Al 1F 1F US 3F 6F 5F 6D _ 7F 3F oF 1F US BF 6F DF 6D _ FF 3F When you select Translate control codes to Control codes the ASCII to EBCDIC table in the software matches the table above Column one contains the ASCII hexadecimal codes for the graphic or control symbol in column three Column two contains the EBCDIC codes for the same graphic symbol The right half of the table 80 FF is a copy of the left half 00 7F which causes the parity bit to be ignored during translation between ASCII and EBCDIC 5 gt an Q EJ 3 es m wo 5 BARR RJE 493 2 ea Lu gzj So 2 m E EBCDIC to ASCII Translation Table E A G E A G E A G E A G E A G E A G E A G E A G B S r B S8 r B r B S r B r B r B r B r c C a c C a c C a c C a c C a CI a Gona Ci Coa D I p D I p D I p D I p D I p D I p D I p D I p I I h tT ch tot op I T ch tet vb I I h I I h I I h c i c i c c i c i c i c i c i c c c c c c c c 00 20 SP 20 DS 40 20 SP 60 2D 80 2 AQ co 7B E0 5c 01 01 SOH 21 sos 41 61 2F 81 61 a Al TE cl 41 A El 02 02 STX 22 2 FS 42 2 62 2 82 62 b A2 73 s C2 42 B E2 53 03 03 ETX 23 wus 43 63 83 63 c A3 74 t c3 43 c E3 54 T 04 SEL 24 BYP 44 64 84 64 d A4 75 u c4 44 D E4 55 U 05 09 HT 25 0A LF 45 65 85 65 e A5 76
31. 249 Defining Function Keys with Replaceable Parameters 250 Using th Prompt 0 055 45 dln aR ae di owls eee eas 250 Using a to Indicate a Missing Parameter 250 Contents 14 5 Using Function Keys with Send Files Commands 252 Including a Send Command in a Function Key Definition 253 Using Function Keys to Send Files to the Host 253 TAO OPUONS prt ces toy A Ade Anan t a thud de chen a E O edie nan teas 255 Chapter 15 Commands Sent at Startup 0 e eee eee 257 15 1 Commands Sent at Startup Screen 0004 257 15 2 Startup Commands for MVS JES2 Example 258 Chapter 16 Startup Screen Notes 000 eee eee eee e eens 259 Chapter 17 Interrupt Request Address and Loopback Test 261 17 1 Adjust Software Settings rea peA ERRE EEE eee eee eee 261 17 2 Perform Loopback Test saga a cee eee eee 264 Test Phases satiated ces cla CARS IS Batts Leese a a Siege deletes atenaye 264 Test Steps rrura assis eiai ons oth hens vdhew god ip Deda EE 266 Test Results sn ict tay cates Enn E ayer ole ae af a a facta Tt me E EAN 268 Chapter 18 Tuning and Global Options 2 05 271 18 1 ASCII and EBCDIC Translation Tables 273 Translation Table Restrictions 0 0 0 0 c eee eee eee 273 Translation Table Menu 0 0 0 cc cee eee eee 273 Choose Language for Translation
32. A a oa Note You can define only one spool directory 3 Finally assign the spool printers SPOOL1 to SPOOL8 to route files to the desired destination devices for example assign SPOOL1 LPT1 from the Assign Devices screen See section 10 7 Assigning Spool as a Destination For more information about software features that affect spool setup or operation see these sections Section 10 9 Options for Assign Devices Chapter 25 Spool PRT Utility Appendix E Spool Header 122 9 2 Checklist for Print Spool Setup KEJ Print Spool Description Screen You can reach all the print spool settings from the Print Spool Description screen gt From the Installation Description menu select Print Spool Description Print Spool Description Spool printers 1 SPOOL directory C SPOOL Retain directory o mj 5 i 2 o D a ir e 3 Ej Escape Advanced Spool Options File Attribute Table FAT Options Initial SPOOL Printer Settings Enter number From this screen you can specify basic spool options and display additional screens that contain more advanced spool options The first two options are required but the third one is optional Spool printers Specify the number of spool printers that service the print spool Spool printers route files from the spool directory to PC printers or other destination devices Specify one spo
33. Display character size 199 color 23 mode 41 Display command JES2 464 Display line or page count 60 73 Disposition See also File attributes PRT 438 spool 409 spool header 511 DLOGMOD parameter 199 DMA request 262 263 conflict 269 DOS device driver name 81 end of file marker 68 69 ERRORLEVEL 456 exit to 337 file format 342 program files 453 publications 5 receive mode 179 requirements 2 screen size 199 201 verify function 309 DOS command copy 107 418 md 60 73 91 mode bw80 41 200 435 move 111 share 39 321 time 208 295 DOS ERROR message 358 359 DOS session 23 349 disabling 311 executing batch process from 311 memory for 304 305 DOS wildcard characters FAT table 139 FCB FORM Translation Table 88 move command 112 send files 340 341 spool form name 148 406 DOS POWER See VSE POWER Dot matrix printer 12 DPI 12 32 See also BARR DPI printer type 94 test printer power off 59 timing delay 59 Draining printer state 406 DSR See Data Set Ready DTR See Data Terminal Ready DUMP file 387 400 DUPLEX FULL 27 DXMAOMOD SYS file 2 DXMCOMOD SYS file 2 DXMEOMOD SYS file 2 E El speed 14 26 EBCDIC character set 184 format 489 interleaved with binary 291 EBCDIC to ASCI 29 edit tables 273 278 explanation of codes 495 table 494 translation 492 EBCDIC ASCI viewing mode 427 Edit ASCII EBCDIC Translation Tables edit order 278 screen 273 Edit Forms 216 examples 221 manual mount with 514 526
34. Index display order 217 editing 518 See also Electronic forms See also File attributes files received with wrong 408 format information 218 JES2 commands 241 maximum number of 216 See also Mount Forms naming 218 283 285 not found 222 options 281 See also Printer attributes printer control data with 104 219 229 scroll feature 218 235 skipping perforation 224 sources for 513 support 22 two page 226 Forms Control Buffer FCB See FCB Frame received in error 368 reject message 365 370 Frame number 802 2 369 Coax 372 Frames 802 2 statistics 381 382 SDLC statistics 378 380 X 25 errors 386 X 25 statistics 384 385 French character set 277 Front end processor FEP 19 27 FTP software 82 Fujitsu Network Architecture FNA 303 Fujitsu printers 93 control codes 98 Full duplex communication 27 DMA 263 modems 297 multidrop line 298 Function Key Definitions screen 247 Function keys assigning commands to 245 displaying last command 249 Options screen 255 question mark prompt 250 256 sending files with 252 347 with replaceable parameters 250 Function Keys screen 245 G Gateway connection 14 pooling 300 Generic printer type 93 Genicom printers 93 95 1255 model 95 Go to Page reprint command 426 Graphic characters 496 Group code 412 spool header 511 H Half duplex communication 27 DMA 263 modems 297 Halt command JES2 480 Hard drive requirements 2 Hardware conflicts 262 flow control 64
35. S nan 1O je EER Startup Commands for MVS JES2 Example This section describes how to enter and save JES2 commands Appendix A lists commonly used JES2 JES3 and VSE POWER commands The commands in the following example display the remote s status devices and forms queue for the jobs waiting to print When BARR RJE starts the PC operator can then view the printers status and decide which jobs to print next Commands Sent at Startup D U RMT15 DF 00000000011111111112222222222333333333344444444445555555555666666666677777777778 12345678901234567890123456789012345678901234567890123456789012345678901234567890 Enter character 1 Enter the D U RMTnn command to display the status of the remote and its devices where nn is the number for your remote In this example the remote number is 15 2 Enter a vertical bar to separate the first command from the second command 3 Enter the DF command to display the remote s forms queue 4 Press Enter to store changes to this screen 258 15 2 Startup Commands for MVS JES2 Example Chapter 16 Startup Screen Notes You can display information about your host computer such as your host computer s name and telephone numbers to call on the BARR RJE Startup Screen Notes screen The host name and phone numbers you enter here display on the PC screen at startup before the software makes the host connection 1 F
36. The Serial Numbers screen displays Serial Numbers for hardware used by this program Show Serial Numbers Escape Selection tl 3 Select Show Serial Numbers A list of serial numbers displays The following example shows the serial number for a SYNC adapter SYNC 260123 N oo o Ej 3 D K Ss N o an Any key 4 Press any key to return to the Serial Numbers screen BARR RJE 401 Notes an o a D S a E E o oo N 402 23 9 Hardware Queries 24 Print Spool Operation From the Print Spool session you can drive multiple printers from a single print queue Even if your mainframe computer supports only one printer stream the print spool can drive up to eight printers from your PC Printing can begin right away without waiting for the end of the file to be received If you have not already set up the print spool see Chapter 9 Print Spool Description for instructions After you use the Print Spool Description options to enable spool features and the Assign Devices options to specify which printers to route spool files to you can begin spool operation During print spooling files received from the host or LAN are stored in the spool directory File attributes such as form class and priority are included in each file s spool header at the time they are received BARR RJE uses these attributes to d
37. The command device sends commands from the remote workstation to the host computer You can use commands to request the following Information about files waiting in print or punch queues That print or punch files be sent to the remote workstation RJE device status Reader You can send data and job files from the remote workstation to the host computer on the reader device The reader is an input device that accepts files Historically a card reader read 80 column punched cards for input to the host Now you can transfer data files on the reader to the host or send them with job files to be processed by the host Job files contain job control language JCL instructions that tell the host how to process the job Console The console device receives messages from the host computer and displays them at the remote workstation These messages tell you the status of jobs and RJE devices such as printers and punches The console BARR RJE 11 2 RJE Concepts is especially important for displaying messages when you print special forms such as invoices and checks Printer BARR RJE sends print output produced by host programs to the remote workstation on the RJE printer BARR RJE formats each page of this output with carriage control characters You can send output files directly from the mainframe print stream to PC printers or save files to disk at the remote workstation for later printing Punch The mainframe transfe
38. batch file A PC DOS file that contains a sequence of DOS commands When you type the name of the batch file at the DOS prompt DOS executes all the commands stored in the batch file as if you had typed them from the keyboard baud The number of changes in line condition per second The term is commonly used as a measure of information transmission speed expressed in bits per second The use of baud to mean bits per second is valid for the RS232 side of the modem binary A base 2 number system used in comput er programming The binary digits or bits are O and 1 binary synchronous communication BSC A low level data link line protocol for synchronous communications first used by IBM It only supports half duplex commu nications bind In SNA communications the operation in which the host and remote logical units LUs initiate a session and agree upon the protocol to be used within that session BIOS Basic Input Output System Program permanently stored in read only memory ROM chips on your PC s system board It is one level below the PC operating system and controls basic hardware operations such as interactions with disk drives hard disk drives and the keyboard All PCs are shipped with BIOS bisynchronous communication bisync See binary synchronous communication BSC bit The name of an elementary unit of information that has two states Usually the two states are called O and 1 blocks A co
39. cu3 Customer Use 3 DC1 Device Control 1 DC2 Device Control 2 DC3 Device Control 3 DC4 Device Control 4 DEL Delete DLE Data Link Escape DS Digit Select EM End of Medium ENQ Enquiry EO Eight Ones EOT End of Transmission ESC Escape ETB End of Transmission Block ETX End of Text FF Form Feed FS File Separator GE Graphic Escape GS Group Separator HT Horizontal Tabulation IR Index Return IT Indent Tab LF Line Feed Control Characters MFA NAK NBS NL NUL POC PP RES RFF RNL RPT RS SA SBS SEL SFE SI SM so SOH sos SPS STX SUB SYN TRN UBS US WUS Modify Field Attribute Negative Acknowledge Numeric Backspace New Line Null Program Operator Communication Presentation Position Restore Required Form Feed Required New Line Repeat Record Separator Set Attribute Subscript Select Start Field Extended Shift In Set Mode Shift Out Start of Heading Start of Significance Superscript Start of Text Substitute Synchronous Idle w gt an Q 2 3 3 m wo 5 Transparent Unit Backspace Unit Separator Vertical Tabulation Word Underscore BARR RJE 495 2 ea Lu gzj So 2 m Graphic Characters SP R Va Space Normally Nonprinting Exclamation Point Quotation Marks Diaeresis Number Sign Dollar Sign Percent Sign Ampersand Apostrophe Closing Single Quotation Mark Acute Accent Opening Parenthes
40. key 3 serial numbers 401 Harris 1610 remote 457 tape support 30 HASP190 519 alternates for 525 Barr option 525 commands sent after 238 enable 524 FCBLOAD with 514 519 job name unreliable 163 286 525 mount forms by 282 283 285 values supplied by 521 Header information 407 Help Barr Technical Support iii Hewlett Packard 451 laser printers 231 274 line printers 93 Hexadecimal codes 493 HIMEM memory manager 304 Hitachi printers 93 control codes 98 Hold command JES2 470 Hold file status 408 Horizontal tab characters HT 490 Host communication role 26 296 457 connecting to remote 457 environment 15 logon 23 mode 457 parameters 19 Host Definition Guide 4 19 49 Host Initiated logon type 296 Host name display 259 local LPR LPD 84 Hot key 349 select 312 HP LaserJet printer 231 274 HT Horizontal Tab characters 490 BARR RJE 559 IBM LAN support program 2 Matrix Printer 230 publications 4 IBM printers 31 93 3270 model 18 6262 model 60 Idle disconnect 301 line 368 time period 301 Ignore lines at start of file 189 192 Initial session 312 Input mode on serial port 68 Inquire command VSE POWER 487 Inquiry command JES3 482 INSTALL command 41 Installation Description 47 command 47 disabling 310 menu 48 Installation Software screen 41 Interleaved binary data 291 International character set 277 Interrupt command JES2 471 Interrupt request IRQ 262 266 conflict 269 serial po
41. 2 00 45 Bypass the Automated Installation Process 45 Chapter 7 Installation Description 000 eee eee eee 47 7A Initial Screens ics is goto sis alas E oO ie Baek Ea a Rca 47 7 2 Installation Description Menu 0 00 0000008 48 vi Contents Chapter 8 Devices and Printers 2000 e cece eee eee 51 8 1 Sources Destinations and Device Assignment 51 8 2 Devices and Printers Menu nanana nannan nee eee 52 8 3 SEPT 1a RY 3 DEVICE sets ccc ais a on A eee tele Ate an ERA 54 LPT Device Menun rereana aa hk Pes EON 54 Miscellaneous Printer Options for LPT Devices 56 8 4 COM1 COM4 Devices 00 00 ec cette nee 61 COM Device Menu iraa sce ik bi eds teal ee a da 61 Serial Port Options 0 0 cece eee ee eee ee 63 Serial Port Source Options 0 0 0 0 02 c eee eee eee 66 Miscellaneous Printer Options for COM Devices 71 8 5 NETI1 NET12 Devices 0 0 0 0 ccc cece cece eee a A 74 NET Device Menu 1 0 0 cc ce een P 74 Network Printer Options 0 0 00 ce eee eee eee 76 Novell Print Quevle 2 em ee a a e a a a 77 Deyice Driyefrenee nee i oo ale BOG a le E E E Oe 81 TCP IP LPR UNIX Print Queue 000 c eee ee 82 FCB FORM to Print Queue Translation Table 87 NET Options dii ri 0 sae wae 208 oo R A fol aa 89 Miscellaneous Printer Options for NE
42. 4850 4890 8790 9790 IBM 3203 3211 4245 4248 6262 m Oc 2050 300 2075 2 2090 2 2140 2 2140 3 2200 2 2200 3 2240 2 2240 3 2300 2 Nipson Series 3000 u Comparex 6890 6900 STK 5000 Series 6100 19 6100 26 The PRINT370 option supports these AFP printers m IBM 3820 3825 3827 3828 3835 3900 a Oc 2030 2 2050 200 2075 200 2090 4 2140 4 2240 4 2300 4 IPDS Group 3 equivalent printers A special IBM 3820 software version is available at no additional charge BARR RJE 31 The PRINT370 option supports these computer output microfiche devices Anacomp DatagraphiX XFP 2000 Kodak Komstar Optistar Micrographics Technology COM 6831 an gt 2 ras wi gt es n cc cc lt a Dataproducts Printer Interface Support The Dataproducts Interface which originated with the Dataproducts Corporation drives high speed printers and typesetting equipment Barr Systems offers the BARR DPI adapter for attaching a PC to a printer with the Dataproducts interface Because BARR DPI appears as a parallel printer adapter LPT1 LPT2 LPT3 to the PC all software used with these ports functions with BARR DPI The BARR DPI adapter is completely compatible with BIOS and DOS BARR PRINT for LAT You can share printing resources with your IBM mainframe and DEC VAX VMS computers The BARR PRINT for LAT option allows your PC to accept VAX VMS print output over Ethernet with the L
43. Barr forms can include an optional printer control index for sending printer control data The values you enter for lines per form print lines per form and lines per inch are not actually sent to the printer The Barr software converts these values to the appropriate commands for your printer type You select the printer type under Devices and Printers for the individual LPT COM and NET devices you enable See section 8 6 Choose Printer Type for more information 216 13 2 Edit Forms Edit Forms Menu You maintain forms from the Edit Forms menu Printer Forms Edit Forms Mount Forms Printer Forms Commands Sent to Host Escape Selection l gt 1 From the Printer Forms menu select Edit Forms oo ms 53 a mn i 3 a The initial menu contains only blank entries Edit Forms select one Escape Selection l gt 2 To create a form move the cursor to a blank entry in the list and press En Alphabetical Display While you are creating forms you can display them in alphanumeric order in the list by leaving and then returning to the forms menu Follow these steps to sort the list 1 From the Edit Forms menu press return to the Printer Forms menu 2 From the Printer Forms menu select Edit Forms and press to display the sorted forms list BARR RJE 217 a E ras D p gt
44. DOS while the Barr software is running Note Unless you also set Disable Installation Description to Yes the operator can re enable the DOS session from the Session and Security Options screen DOS session executes AUTOCMD BAT Select whether BARR RJE will automatically run a batch process each time you change to the DOS session You can use this feature to automatically run an application program in background DOS No Default A batch process is not automatically run from the DOS session Yes The batch file AUTOCMD BAT is immediately executed if BARR RJE is started in the DOS session or if you switch to the DOS session during operation You must create a file named AUTOCMD BAT that contains the desired DOS commands and then put the file in the same directory as the BARRSNAR EXE program file BARR RJE 311 Initial session is Select which session displays as the initial session when you start BARR RJE You can switch between sessions with the Sessions command on the Advanced menu or by using hot keys See section 21 5 for more information about changing sessions OPER Default When you start the software it begins in the Operation session The Operation screen displays Starting in this session lets you monitor the process of connecting to the host DOs The software starts in the DOS session The DOS prompt displays PRINT The software starts in the print spool session The Print Spool screen displays Sessionl Se
45. E o m N Table 23 2 Bind Data Description continued Byte Values Description LOGMODE 10 F4 Input buffer size 240 RUSIZES X F4F4 F5 Input buffer size 480 RUSIZES X F5F5 F6 Input buffer size 960 RUSIZES X F6F6 11 85 Output buffer size 256 86 Output buffer size 512 87 Output buffer size 1024 F3 Output buffer size 120 F4 Output buffer size 240 F5 Output buffer size 480 F6 Output buffer size 960 12 07 Host RJE to Controller PSND PAC 7 pacing LU VPACING 7 13 07 Controller to Host RJE pacing APPL VPACING 7 14 01 LU type 01 PSERVIC X 01 15 10 FM header set 1 PSERVIC K 0110 16 20 LU profile for PDIR PSERVIC X 011020 SETUPHDR 40 LU profile for compaction PSERVIC X 011040 60 LU profile for compaction PSERVIC X 011060 and PDIR SETUPHDR 17 00 Reserved PSERVIC X 01106000 18 91 SCS output Full base PSERVIC K 0110600091 TRN IRS F1 SCS output FCBLOAD PSERVIC X 01106000F1 without SLD F9 SCS output FCBLOAD PSERVIC X 01106000F9 with SLD 392 23 5 Bind Data Table 23 2 Bind Data Description continued Byte Values Description LOGMODE 19 00 Not used PSERVIC X 01106000F900 20 co Output media PSERVIC X 01106000F900C0 document and card files E0 Output media PSERVIC X 01106000F900E0 document card and exchange files 20 Output media PSERVIC X 01106000F90020 exchange fil
46. Escape Options Selection gt 2 Select which group of function keys to edit The Barr software supports 40 function key variations a F1 to Fi0 C0 FD o Ga FL to a Alt F to F10 BARR RJE 245 You can assign functions to the first 39 key combinations The combination is reserved for the repeat command function discussed in section 14 3 14 2 Entering Key Definitions The to keys have already been defined with frequently used JES2 commands but you can change the definitions if necessary You must change the remote number in the and key default defini tions to correspond to your remote number Get the remote number from your host operator The other function key combinations that use Shift Ctrl or Alt are blank and ready for you to enter definitions Each function key definition screen looks the same except for the screen title You can enter a brief 24 character description of the key s function on the first key definition line During program operation this description displays when you use the Command to Host option to help you determine each key s meaning The second line contains the actual command sent to the host when you press the function key gt x i oO Lu a If you have an RJE system other than JES2 and need help with host commands consult your host systems operator or your RJE system documentation Definition Guidel
47. HASP190 FCBNAME eliminate C for FCB from the work selection criteria with the JES2 Set Printer command T PR1 WS C Note Only the form name provided by the HASP190 message is reliable Other information such as the job name might not be reliable because the host sends the HASP190 message only when the form name changes Special Use The HASP190 message can be used with the FCBLOAD feature If Use Barr FCBLOAD is set to Yes and Mount forms by is set to HASP190 FCBNAME you do not need to define forms in the Barr software Instead the FCB information from the host is used to format the data and the HASP190 message supplies the form name placed in the Barr spool header for display on the Print Spool screen Disable form mount error messages Choose whether the software displays error messages if a form is not found in the Barr Edit Forms table No Default Form mount error messages are not disabled and therefore will display This choice is useful if you are defining printer forms in the Barr software and want to be alerted if a required form is not defined a i A i o r Yes Form mount error messages are disabled This choice is useful if you are not defining Barr forms It omits error messages that can be ignored For example if you only print to Xerox channel attached laser printers you do not need to use the Barr Edit Forms table Use this choice to prevent error messages from disp
48. NMVT 395 Network Printer Options screen 76 device driver 81 Novell print queue 78 TCP IP LPR UNIX print queue 82 Network Problem Determination Application NPDA 394 Network type NET device 76 New File option 165 170 171 New page at end of file 57 72 Nipson printers 31 NLDM 394 NMVT 395 No Form option 235 Non switched line 14 NOSEP JES2 parameter 192 Not autodial modem 203 Not sign translation of 491 Novell network 159 PRINTDEF utility 81 Novell IPX 14 Novell job queues 113 receive files from 156 Novell NetWare banner page 114 117 form name 117 queues 54 113 116 118 Novell NetWare for SAA 27 Novell print queues 74 75 77 113 159 form number 81 options 78 translation table 87 user connection 78 114 Novell Queue devices 153 156 enable 54 screen 114 NPDA 394 NUL device 153 155 157 Null modem cable 498 Nulls strip leading 69 NW QUE devices 54 115 153 156 enable 116 O Oc printers 31 AFP models 31 extended memory 305 form overlay files 100 forms 515 OKIDATA printers 93 92 and 93 models 105 control codes 97 OPER screen size 199 201 session 312 349 Operation menu driven 22 unattended 24 Operation screen 323 333 mount forms by 284 startup notes 259 Operation session 312 349 Operator alerts 397 commands 23 Operator Generated Alerts screen 398 Option manuals 4 BARR RJE 563 Options Assign Devices 185 186 function key 255 network printer 75 serial por
49. On the Network Printer Options screen specify how files are routed to network printers gt From the Devices and Printers menu for the selected NET device select Network printer options Network Printer Options NET1 network type Novell Print Queue printer type Generic Choice network type Choose which type of network printer to use After you make a selection additional options display on the lower half of the screen Three choices are available 76 8 5 NETI NET12 Devices Novell Print Queue Default Direct the output files to the specified Novell print queue This choice allows you to route files to any print queue on the Novell network See Novell Print Queue later in this section Device driver Direct the output files to the specified DOS device driver See Device Driver later in this section TCP IP LPR UNIX Print Queue Direct the output files to the specified LPR print queue To see this choice you need to request a special version of software from Barr Systems See TCP IP LPR UNIX Print Queue later in this section oo i oO S o D a 2 Ss s m Ss a a printer type The printer type you select on the Printer Type screen displays here Novell Print Queue When you select Novell Print Queue as the NET device network type you need to set the options described in this section Network Queues and Servers On the network files are stored in que
50. PRINT370 and SYNC MAX ISA are trademarks of Barr Systems Inc Other Trademarks IBM SNA PC AT PS 2 Micro Channel NetBIOS NetView System 360 System 370 Token Ring VTAM and AS 400 are trademarks of International Business Machines DEC VAX VMS LAT and DECnet are trademarks of Digital Equipment Corporation Xerox and Ethernet are trademarks of Xerox Corporation Dataproducts is a trademark of Dataproducts Corporation MS DOS is a trademark of Microsoft Corporation WordPerfect Novell NetWare and Internetwork Packet Exchange IPX are trademarks of Novell Inc UNIX is a trademark of Unix Systems Laboratories PostScript is a trademark of Adobe Systems Inc QEMM is a trademark of Quarterdeck Office Systems Banyan and Vines are trademarks of Banyan Systems Inc Cross Connect is a trademark of Smith Micro Software Inc 6 1 4 Trademarks EEJ Acknowledgments Barr Systems thanks the following people for their suggestions for improvements to the BARR RJE manual _t 5 gt e 2 ix 5 Mark Byrd Hewitt Associates LLC Lincolnshire IL Maynard Calkin Northeast Regional Data Center Gainesville FL Rick Foley Siemens Nixdorf Printing Systems Boca Raton FL Dale Fulk Electronic Data Systems Indianapolis IN Steve Glick Dallas County Community College District Mesquite TX Earl Gulczinski
51. Perform analog loopback test Yes Choice The software performs cable and modem Signal and Send Receive tests for Phase 3 5 Follow the instructions on the screen and then press to start the test Test Results If the loopback test fails you need to know which phase failed Watch the messages on the screen TEST PASSED or TEST FAILED displays for each phase At the end of the loopback test a summary message displays TEST RESULT TEST PASSED Return the modem to normal mode Any key A TEST PASSED message indicates all phases passed A TEST FAILED message indicates one or more phases failed 268 17 2 Perform Loopback Test A failure in Phase 1 or 2 could indicate a problem with the adapter configuration Check the following Is there an IRQ conflict with another adapter If so follow the instructions in section 17 1 to reset the IRQ a Is the adapter address you specified in the software the same as the jumper settings on the adapter If not follow the instructions in section 17 1 to change the adapter address in the software a Is there a DMA conflict with another adapter If so follow the instructions in section 17 1 to reset the DMA a Is the adapter installed correctly Make sure the adapter is firmly in the slot Is the adapter making a clean connection Try cleaning the adapter slot connectors with a pencil eraser A failure in Phase 3 usually i
52. Retry option NET device 90 Return to Installation Description 317 RJE Description screen 19 RJE printers 155 display status of 241 RJE punches 12 155 data format 178 delete first two records on 192 RJE readers 159 RJE workstation emulation 10 RJE 3270 10 17 30 396 3270 session 312 printer error 292 screen size 199 translation tables 278 280 Route command JES2 475 Routing files from LAN 156 to network 168 to network printer 159 to printer 160 to SPOOL directory 159 174 to spool printers 156 175 to user 168 RS232 adapter 263 cable 13 pin flow control signal 64 RTM See Response Time Monitor RTS See Request To Send S S 370 format 433 printers 31 S 370 channel interface 12 printer form overlay file 288 receive mode 181 273 S 3X systems 32 Sand Technology printers 93 control codes 98 SAP buffers 381 Satellite communications 27 Satellite link modulo 128 mode 368 Saving configuration settings 315 Scope characters 363 802 2 369 Coax 371 dial up 327 364 SDLC 364 379 X 25 365 Screen appearance in text 33 blinking 309 borders 202 clear 308 cues 34 display 308 keys 35 lock 308 navigation 33 pausing display 353 scrolling rate 308 309 353 sizes 199 SCREEN device 153 157 assign CON to 155 Screen save option 307 programs 202 SCS carriage control 184 SDLC 26 communications 16 communications statistics 377 379 connection 15 DSR 0 message 324 scope characters 364 368 379 tuning op
53. Subsequent messages contain information you can use to resolve the error For example if this message displays next DOS ERROR file not found 430 24 8 Managing an External FAT File check whether you specified the correct name and file path for the external FAT file on the Print Spool Description s Advanced Spool Options screen Refresh the FAT Each time you start the Barr software it automatically applies any FAT file changes If you modify the FAT file from a background DOS session while BARR RJE is running you must use the Check Spool command to immediately apply the changes The software will not apply the FAT table changes to incoming files until you issue the Check Spool command You do not have to view the FAT file by setting Display Spool FAT entries to Yes for the changes to take effect but you should view the changes to check for errors before you resume spool operations Note During software operation your PC might not have enough memory for you to edit the FAT file from a background DOS session N A m 3 N g o So 3 e S BARR RJE 431 Notes i o So i i 72 pan A Q N 432 24 8 Managing an External FAT File Spool PRT Utility The Barr spool PRT utility lets you copy files from the PC or LAN to the print spool directory and preset the spool header attributes for each file If you have the Barr PRINT370
54. Table 10 1 Data Sources A Data Source Source Device Name PC file SEND1 SEND2 PC keyboard KEYBOARD PC serial port COM1 COM4 Console message CON Console log file LOG RJE printer PR1 PR7 RJE punch PU1 PU4 Spool printers SPOOL1 SPOOL8 File from LAN directory LAN1 LAN4 File from Novell queue NW_QUE1 NW_QUE4 Table 10 2 Data Destinations Data Destination Destination Device Name Network printer PC file FILE PC screen SCREEN Discard NUL Suspend flow SUS PEND PC parallel port LPT1 LPT3 PC serial port COM1 COM4 Host COMMAND Host file RD1 RD4 Spool directory SPOOL NET1 NET12 BARR RJE 153 Sources The available source devices display on the Assign Devices screen Each source device displays before an arrow Source devices include devices you enable and devices the software automatically provides Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PU1 SUSPEND SPOOL1 LPT1 Select SOURCE DESTINATION Escape Selection l gt SEND1 SEND2 You can direct files on disk to a destination by using one of the send devices Data is not routed until you issue the Send Files command from the Operation screen The most common example is to submit a job to the mainframe computer with SEND1 RD1 4 2 gt 7 i K You can enable the send devices from the Devices
55. This will prevent any files from printing while you check the FAT table and resolve any errors You can enable the printers after you verify that the external table is working correctly Follow these steps to view the FAT table 1 From the Print Spool screen select Check Spool The following prompt displays at the bottom of the Print Spool screen The prompt includes the path and file name for the external FAT file The SPOOL FAT file C BARR FAT TBL has been read into XMS memory Display SPOOL FAT entries No Choice 2 Set Display SPOOL FAT entries to Yes BARR RJE displays the entries from the FAT file in an easy to read table format File Attribute Table Set file attributes for print spool Filename Form State Class Prty Copies Disposition Y PAYROLL HOLD 1 1 1 INVENTORY Hold 2 2 3 F TAX 1040 T TAX 1040A T A TAX 1040EZ T Ss W 2 APPL 8X11 100 o SUPPLIES BAR132 B 3 p ACCOUNT NEW BAR132 A 4 ry TRAVEL EXPENSE Retain SALES RPT YTD BARR132 5 s ACCT INVOICE A DEFAULT DEFAULT 1 of 12 entries PgUp PgDn Esc This sample table contains an error on the first entry line See Diagnose and Correct Errors later in this section for more information about detecting and resolving table errors BARR RJE 429 In the lower left corner of the screen the software displays the number of table entries and the number of the entry that is at the top of the screen The to
56. UNIX print queue to route files to printers You can use different types of network printers Each NET device uses a separate set of printer control data NET Device Menu 1 From the Devices and Printers menu select NET1 12 A list of NET devices displays NET Devices NET Options Escape NET1 Delete NET2 Delete NET3 Delete NET4 Delete NET5 Delete NET6 Delete NET7 Delete NET8 Delete NET9 Delete NET10 Delete NET11 Delete NET12 Delete Selection tJ7 2 Select NET1 74 8 5 NETI NET12 Devices Devices and Printers NET1 deleted Use this device Delete this device Network printer options Choose printer type Escape Miscellaneous printer options Printer control data Escape oo oO S o D an 2 Ss ies me Ss e a Selection tJ gt The same choices display for each NET device Use this device Enable the NET device You must select this option to enable the device before you can use it The selected device displays as a destination choice on the Assign Devices screen Delete this device Default Disable the NET device and remove it from the Assign Devices screen The status deleted displays next to the device name at the top of the screen The Assign Devices screen is easier to read if you delete devices you do not intend to use Network printer options Select which type of network printer to use Choice
57. When error or paper displays on the Status Line a beep will sound This choice is especially useful for laser printers Unlike line printers you usually cannot hear a laser printer stop when a problem occurs Test for D P I printer power off This option is valid only for printers with a Dataproducts Interface DPI Use this option to test for a printer power off condition Some printers and some older BARR DPI adapters do not support this test To determine if your printer supports the test set this option to Yes and turn off the printer The Status Line on the second line of the BARR RJE Operation screen should display Off for the printer Next turn the printer power on The Status Line should BARR RJE 59 show a status other than Off If the status does not respond correctly disable this option For more information about the Status Line see section 20 2 No Default Do not test for the power off condition Yes The software determines whether the printer is powered off before it attempts to send data to the printer This choice should work with all DPI attached printers except the IBM 6262 Display count of lines or pages This option controls the count of lines or pages printed that appears on the Operation screen s Status Line and in the Print Spool screen s Units column For more information about the Status Line see section 20 2 For more information about the Print Spool screen see Chapter 24 n o 2
58. and VS1 RES systems another solution is to use the BARR TRAN mainframe program This program is provided on the Barr software disk and is usually installed in the C BARR TRAN directory BARR TRAN can transfer variable length records and handle records of any size For more information about using BARR TRAN request a BARR TRAN manual from Barr Systems 4 2 gt 7 i K Fixed length A format for special applications usually situations that require the received data to contain fixed length records Fixed length records are records of equal length For example you can use Fixed length receive mode to receive data to magnetic tape or receive data that will be processed by a PC program For the SEND1 to SEND2 LAN1 to LAN4 and SPOOL1 to SPOOL8 source devices Fixed length is the only receive mode supported You can use Fixed length for these devices only when BARR RJE writes to magnetic tape requires BARR TAPE When you select Fixed length additional options display at the bottom of the screen See Fixed Length Receive Mode later in this section for a description of these options 180 10 8 Receive Mode Transfer files An internal intermediate format used for general file transfer from PC to PC or with the mainframe program BARR TRAN for transferring between MVS and PC file structures See section 26 2 for examples of applications that require this format 370 Channel Required when you print to
59. are stored Include the drive letter and full directory path Remember to create the actual directory with the DOS make directory md command If you do not intend to use this feature leave the directory name blank For more information about this feature see section 8 7 BARR RJE 9 oO i D S o D a 2 3 me Ss e a Printer Control Data for Network Printers Printer control data has some uses that are especially important to NET devices Printer Reset Strings It is important to send an appropriate reset string at the beginning of each file printed on a network printer These printers print data from many different applications Data from the Barr software might not print correctly unless the software sends the proper reset string n o 2 E a 3 G a a Fq oa You can enter a printer reset string in the Printer Control Data table for each NET device with a network type of Novell Print Queue or Device Driver For more information about printer control data see section 8 8 Using Form Overlay Files as Reset Strings You can use form overlay files to send reset strings to network print queues when you set the NET device network type to Novell Print Queue or TCP IP LPR UNIX Print Queue and use FCB name or form name to route output to different types of printers Set the Search for form overlay by option to FCBNAME or FORMNAME on the Tuning and Global Optio
60. but you can use the HASP190 message to provide that information For detailed information about the FCBLOAD function see the IBM publication IBM MVS Extended Architecture System Data Administration GC26 4010 Adding a UCS Image to the Image Library nm T i 3 Eg i 3 f z i 5 BARR RJE 519 FCBLOAD Information The FCB consists only of format information provided by the SNA Set Vertical Format SVF and Set Line Density SLD commands The IBM publication SNA Sessions Between Logical Units describes these com mands The information provided by each command is listed below Most of the information is provided by Set Vertical Format Set Line Density supplies only the lines per inch setting Set Vertical Format The SVF command provides this information Definitions for carriage control stops 2 to 12 a Lines per form Top margin Bottom margin The Barr software calculates the print lines per form from the top and bottom margins Set Line Density The SLD command provides vertical line spacing also known as lines per inch At the host line spacing is measured in typographical points where 1 point is 1 72 of an inch On this scale 6 lines per inch is represented as 12 points and 8 lines per inch is 9 points The Barr software performs this calculation HASP190 Information The FCBLOAD information does not contain a form name FCB name or job name but you can use the HASP
61. follows the command is sent to the destination assigned to the COM device for example COM1 RD1 To use the command to host feature include a backslash as the first character of the original file When the file is input on the serial port BARR RJE checks for the beginning backslash Data that follows the backslash is sent as a command to the host as if you had issued it with the Command to Host option on the Operation screen Terminate 66 8 4 COM1 COM4 Devices the command with a carriage return or an end of file marker You define the end of file marker on the Serial Port Source Options screen You can include consecutive commands at the beginning of the file Precede each command with a backslash and end each command with a carriage return The Command to Host option selected from the Operation screen and the leading backslash feature input from the serial port require you to assign KEYBOARD COMMAND on the Assign Devices screen Section 21 2 describes the Command to Host option co i D S o D a 2 Ss Z me Ss e a Error Handling for Serial Input If a receive error occurs during input from the serial port and it causes a character to be lost the software inserts a question mark in the file and displays this error message on the console Input from COM1 lost a is substituted for lost character This error condition might be produced when software other than BARR RJE such as LAN
62. i K Assign Devices ASCII data with ASA carriage control No OUTPUT statement used in file No Class 1 Spool header from data No Ignore 0 lines from start of file Create separator files No Write spool header to file No Strip spool header No Choice The options fall into two categories options that affect the spool header and other options The options you select will affect all files received on the source device Each time the software starts the options from the Installation Description are used You can change the Assign Devices options during software operation Restrictions for Assigning Options You might not be able to use all the options with every device or every receive mode Just because an option displays does not mean it is valid in a given case Additionally in some cases you cannot use certain options together You can set different options for each source device When you assign options keep these points in mind You can use options with the PR1 to PR7 PU1 to PU4 SEND1 to SEND2 and LAN1 to LAN4 source devices a Options are not valid for the COMMAND CON LOG and SPOOL1 to SPOOL8 source devices Options that Affect the Spool Header All the Assign Devices options except Ignore n lines from start of file and Create separator files affect fields in the Barr spool header File attributes from the Barr spool header display on the Print Spoo
63. if the software already is logged into a given server with print queue rights the existing login is used No additional login is performed even if the Barr software is logged into the server with a different user name than that specified in the User name field If the Barr software performs a login to connect to a print queue the software will log out when the print job completes BARR RJE can be logged into only eight file servers at one time If a login is needed but the software already is logged into eight servers login is deferred until a print job completes and frees a server slot If a NET device is unable to connect to the specified server queue because the server queue is unavailable it will retry the connection repeatedly at five minute intervals n o 2 E a 3 G a a Fq oa See Network Connections earlier in this section for a discussion of the available server connections Retry wait time _ minutes zero to disable This option and the next one affect files that are directed from the print spool to a net device for example SPOOL1 NET1 When file transfer from a spool device to a NET device fails choose whether to put the spool file on hold or retry the transfer If you specify 0 for this option BARR RJE puts the file on hold If you specify a value other than zero BARR RJE sets the spool state to Retry and waits the specified number of minutes before re attempting the transfer T
64. large number of files you should periodically delete the files from disk so the hard drive does not become full Yes Retain files are deleted automatically after the specified retain period has expired Retain files for _ days Specify the number of days that files will be retained before they are automatically deleted The default retain period is 7 days When files are moved to the retain directory the date and time are changed to the current PC date and time to enable tracking of the retain period The software deletes the expired retain files each time it starts and at midnight when the PC system date changes 110 8 10 LANI LAN4 Devices This option is valid only if Delete old Retain directory files is set to Yes Start JCL file Optional The file is sent immediately before each file This feature is often used to send Job Control Language JCL with files that will be submitted to the host as jobs You must put the start file in a separate directory When you specify the start file name include the drive letter and full directory path End JCL file Optional The specified file is sent immediately after each file For example you can send JCL at the end of a job You must put the end file in a separate directory When you specify the end file name include the drive letter and full directory path co i o S o D 2 iJ Ss s m Ss a a Error Handling for LAN Connections When a file is sent
65. oo o o 3 o K Ss an o an E28 Bind Data Bind data defines the operational rules for each partner LU Choose the Bind Data option to display the bind data The bind data originates from the VTAM LOGMODE table the PU definition and the RJE system JES2 parameters override LOGMODE parameters for the bind data Diagnostics Communications Statistics VTAM Commands Line Trace Memory Dump Bind Data Escape Selection l gt 1 From the Link Diagnostics Diagnostics menu select Bind Data LIU 0 1 2 3 4 5 6 7 8 910 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 31 01 03 03 B3 A3 70 80 07 07 86 86 07 07 01 10 20 00 91 00 CO 00 00 01 00 40 2 31 01 03 03 B3 A3 70 80 00 07 86 86 07 00 01 10 20 00 91 00 CO 00 00 01 00 40 3 31 01 03 03 B3 A3 70 80 00 07 86 86 07 00 01 10 20 00 91 00 CO 00 00 01 00 40 4 31 01 03 03 B3 A3 70 80 00 07 86 86 07 00 01 10 20 00 91 00 CO 00 00 01 00 40 This screen displays the bind data for all LUs 2 Scroll through the LUs with the and keys You might need to press more than once to change the display The line with a blank LU number contains an RJE bind data sample The other lines show actual bind data Each bind data byte is assigned a number from 0 to 25 Bytes 14 through 25 of the bind data correspond to bytes 1 through 12 of the LOGMODE data s PSERVIC parameter For more information about the PSERVIC parameter see Chapter 1 of the Ba
66. or key on the keypad to toggle through choices Enter character Type a character Enter number Type a number Enter hex number Type a hexadecimal number by using digits 0 through 9 and letters A through F 34 5 2 Screen Cues EEJ Screen Keys You can use the keys listed below on all screens even if they do not appear in the screen cue Keys appear as key symbols in the text A key functions the same across most screens The text indicates when a key s function differs Use the up arrow down arrow and tab keys to move between fields on a screen Press the up arrow to jump from the first to the last field on a screen Use the right and left arrow keys to move between fields and within a field o N r o o O z3 lt 53 gt a Use the Delete key to delete the current character Esc Use the Escape key to return fields to their original values and return to the previous screen Use the Enter key to retain data on the screen and advance to the next screen On some installation screens additional options display when you press the key BARR RJE 35 Notes suonuanuos uaalasS G 5 3 Screen Keys 36 Chapter 6 Software Installation This chapter describes how to configure the PC files to work with Barr software install the Barr software files and reach the software configuration settings z N i 2 o 5 N e 9 a i
67. select PR2 as the data source 2 Select FILE as the destination The file name screen displays 168 10 5 Assigning a File as a Destination Assign Devices Beginning of file name F Ending of file name is formname jobname New file Log Choice 3 Enter the drive letter F as the Beginning of file name 4 Select formname jobname as the Ending of file name 5 Use the default options New File and Log When you press Enter the Assign Devices screen displays the Beginning of file name in parentheses after the source name A 2 2 5 i S o D 2 Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PR2 F PU1 SUSPEND SPOOL1 LPT1 Continue Escape Receive mode Options Help When users submit a job they must specify the job name and form name in the JCL For example if Gary wants output from a job routed to his network directory he includes some statements similar to the JCL sample below in his job SOBABC JOB 7000 4250 1 2 0 G SMITH JOBPARM FORMS GARY In this example the jobname is JOBABC and the form name is GARY When the output file is generated the complete file name is F GARY VOBABC 001 which means the file JOBABC 001 is placed in the directory F GARY Example 3 Route Mainframe Output to FILE A common application is to route output from the mainframe to a PC disk file by usi
68. size and provide it to the LPR LPD protocol Before it can process files LPR LPD must be informed of the exact file size The LPR file size includes the size of any overlay files native TCP IP Files must be directed to a destination that uses the native TCP IP protocol Files do not have to be written to the PC disk before you send them This choice is useful when BARR RJE communicates PC to PC across TCP IP where the other PC running BARR RJE is on a different LAN For example you can receive data on one Barr PC and send it across the Internet to another Barr PC with the BARR PRINT for TCP IP option where it will be printed BARR RJE 83 o oO S o D an 2 Ss ies me Ss e a n o 2 E a 3 G a a Fq oa Print server address Enter the IP address or equivalent host name of the print server where files will be sent Print queue The name of the print queue on the print server If you select native TCP IP as the protocol this field is optional Local Host name User A name indicating the Barr PC node name When you view a queue of files on a host it is helpful to determine the file source The local host name is added to the LPR LPD control file on the host and is required by some LPDs ID The name of the user submitting the job You must specify the same user ID for all your NET devices When you view a queue of files on a host the user ID
69. used after it is received to the PC Some of the same options are available for both receive mode and send mode Send modes are discussed in section 21 4 When you assign a receive mode to a device keep these points in mind a All receive modes are valid for the RJE printer PR1 to PR7 and RJE punch PU1 to PU4 source devices You can use only the Fixed Length receive modes for the SEND LAN and SPOOL1 to SPOOL8 source devices Fixed length is useful for these sources only when the destination is TAPE requires the BARR TAPE option None of the receive modes are valid with COMMAND CON or LOG The selected receive mode affects all files received on the source device You can change the receive mode during software operation 176 10 8 Receive Mode Note When the data from the mainframe arrives at the PC it might not be in exactly the same format as it was at the host computer because the RJE system processes the data stream as it leaves the host The receive mode in the Barr software changes the data received from the RJE system Receive Mode Menu To reach the Receive Mode menu follow these steps 1 From the Assign Devices screen assign the source device to a destina tion A menu line displays at the bottom of the screen _ A 2 5 i S o 7 Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD gt COMMAND CON SCREEN LOG NUL PR1 SPOOL PU1 SUSPEND SPOOL1 LPT1 Continu
70. 03 28 97 11 49 Spool File File Directory DOS Controls View File Quit Copy a file into the spool directory 3 Select a file in this example FILEDESC LST with the arrow keys or press to cancel A FILEDESC LST BLANK ARC BLANK16B ARC BLANKOP ZIP BLINK120 ARC BLNKET11 ARC BLOCKCUR ARC BORDER ZIP 13159 890530 Screen blanking utility with MASM source 31415 890806 Screen blanker 7061 900922 Screen saver for all IBM PC compatibles 1271 880829 TSR simulates non blinking cursor 17988 890621 Screen blanker scrolls message time 8888 890910 Control your true hardware cursor 9718 910112 Set screen border color using BIOS rtns CHANGE ARC CLEAR ASM gt BOSSKY13 ZIP 53757 900319 Capture screen to disk display captured a e BUFFIT20 ARC 9114 890315 TSR screen backscroller v2 0 x BURNO231 ARC 18371 900120 Screen blanker v2 31 works on diff vid 5 CAPBUF ARC 37032 891105 TSR captures any text screen to disk S CGA ARC 5285 900120 CGA simulator for HERC from New Zealan 7 CGA10 ARC 5390 890520 Run CGA programs on Herc Monochrome sys te N 6400 870531 Change DOS bkground and fground screen B B B B B B B B BRITELN ZIP B 4422 901203 TSR makes prompt line reverse video B B B B B B A 899 830825 Fast clear screen function Assembler c Escape to Stop 4 Use the Home End Pg Up Pg Dn and arrow keys to examine the contents of the file and jump to the beginning
71. 1010 333 777 TBARR EXEC PGM IEBGENER SYSOUT DD SYSOUT A SYSUT2 DD SYSOUT A SYSUT1 DD H C DATA FILE2 B 1 In the JCL file enter the embedded send files command with the B send mode 2 Use the Send Files command on the Operation screen to send the JCL file BARR RJE 345 N o gt gt J a m i 3 2 5 BARR RJE interprets the embedded send command and sends FILE2 with the JCL As BARR RJE sends the JCL file it converts it from ASCII to EBCDIC Because of the B send mode BARR RJE does not perform data translation for FILE2 Send Files at Software Startup When you issue the software startup command you can tell BARR RJE to send files Add the name of the files to transfer to the end of your startup command Use a comma to indicate which SEND device to use To send files on SEND1 list the files immediately after the startup command To send files on SEND2 type a comma after the startup command and then type the file list Note If BARR RJE restarts these files are not re sent Example 1 Send Files on SEND1 and SEND2 To send a file on each send device use this command format barrsnar job1 job2 The JOB1 file is sent to the destination device assigned to SEND1 and the JOB2 file is sent to the destination device assigned to SEND2 i o a i Wu c gt s c co rr N Example 2 Se
72. 2 gt 7 i K 198 10 11 Plot Output Assignment Monitor and Adapter BARR RJE supports standard PC monitors and adapters From the Monitor and Adapter screen you can specify the type of monitor and monitor adapter installed in your PC You can also select screen sizes for the OPER DOS SPOOL and TAPE sessions you use during software operation If you have RJE 3270 the DLOGMOD host parameter controls the screen size for 3270 sessions With many adapters you can specify a screen display size larger than the 25 rows by 80 characters normally used on the PC BARR RJE supports screen sizes of 43 x 80 50 x 80 44 x 132 and other choices for some adapters sk _ Ss v Ss gt 2 2 3 You must have a VGA adapter and monitor to use a 132 character display PCs with built in VGA adapters require a multiscan monitor to display 132 characters EER Monitor and Adapter Screen gt From the Installation Description menu select Monitor and Adapter The Monitor and Adapter screen displays Monitor Adapter OPER screen size DOS screen size SPOOL screen size TAPE screen size Screen Borders Enabled Monitor and Adapter Default Default 25x80 25x80 25x80 25x80 Yes Choice BARR RJE 199 Specify the type of monitor and monitor adapter installed in your PC and the screen sizes you want to use for softwa
73. 2 Connection a a E cece eee eee 369 802 2 Scope Characters 0 0c eee cee eee eee 369 802 2 Examples 2 5 0 Sak a aiewtiee tena eels Gas ealings aoe 371 224 Coax COnmecti On 05 520 ek beks dade bale tees wok ed eed BN ane abt 371 Coax Scope Characters sery eesosa ieena ciety wig elelh wera 3 371 Coax Examples ie aiei Era vied doe dire E E EN EE KGE 372 Chapter 23 Communications Diagnostics assssassue 373 Dail Statis ieS i aa yh 4 aa a Meth a aAA 374 23 2 Link Diagnostics o ret eo EEEE a ENAREN 375 23 3 Communications Statistics 0 0 0 0 eee eee eee 376 SDLC Communications Statistics 0 0 0 0 eee eee 377 802 2 Communications Statistics 0 0 0 0 cee eee 380 Coax Communications Statistics 0 0 0 0 0c eee eee eee 382 X 25 Communications Statistics 0 0 0 0 eee e eee 383 BARR RJE xiii 23 4 23 5 23 6 23 7 23 8 23 9 Chapter 24 24 1 24 2 24 3 24 4 24 5 24 6 24 7 Lie kraca r agen aa eons en a tails CA ee fens 387 Bind Data ceureu eaten se Os is eae keane 390 VTAM Commands 00 c cece eee eens 394 INGtVIEW cece cect antes Rot Mina dak Rat nancial enna et 394 Response Time Monitor Screen 0 0 c eee eee eee 396 Operator Generated Alerts Screen 00 008 397 Memory Dump ecs fcc coe cess ae tines re hake Seale ved oe Hele ells 398 Hardware Queries 00 cece cece eens 401 Print Spool Operation 0
74. 20 2 Monitoring the Connection Process The Communication Scope reports call progress Special scope characters called dial up scope characters indicate the activity taking place Dial up scope characters see Table 20 2 display in white and show the activity taking place For instance you can see if the phone number was dialed if there was no answer or if the line was busy Table 20 2 Dial Up Scope Characters Character Description A Answer tone Host modem sent answer tone to remote B Busy Host modem is busy D Dialing In the process of dialing N No answer tone No answer tone has been detected Modem will redial R Ringing Host modem is ringing S Dial up scope characters usually appear in combinations on your Communication Scope as in the following examples 3 J a DB Dialing Busy oe 5 DRA Dialing Ringing Answer tone Z DRND Dialing Ringing No answer tone Redialing Connecting via a Dedicated Line or Network If your PC connects via a dedicated line or network connection startup is automatic The following screen indicates startup is complete BARR RJE 327 CENTRAL HOST NAME COMMUNICATION SCOPE DRAXid XidrsnrmUaRrRr0 0 23 16 LPT1 0 normal 8 00 21 Operation Command to Host Send Files to RD1 Advanced Quit Send Files to SCREEN Mount Forms Selection l gt Connecting via an External Modem with Manual Dial If you use an external modem and
75. 235 Mount Forms Select form No form for PR1 CHECKS PERF STD Scroll STD2 Selection i gt 1 Select a form for PR1 For example select the form CHECKS 2 Press to mount the form and return to the Printer Forms menu Example 2 Assign Forms When Several Printers are Defined This example shows how to assign forms if you have defined several RJE printers When you select Mount Forms a list of printers displays Mount Forms a E ras o a Gr pas Select printer PR1 No form Escape PR2 No form Selection l gt 1 Select a printer For example select PR1 A list of available forms displays Mount Forms Select form No form for PR1 CHECKS PERF STD Scroll STD2 Selection t gt 2 Select a form For example select CHECKS After you make a selection you are returned to the Mount Forms menu which reflects the new assignment Mount Forms Select printer PR1 CHECKS Escape PR2 No form Selection l gt 3 Select another printer In this example select PR2 236 13 4 Mount Forms The forms list displays Mount Forms Select form No form for PR2 CHECKS PERF STD Scroll STD2 Selection t gt 4 Select a form In this example select PERF After you make a selection you are returned to the Mount Forms men
76. 6 Restore Command Printers Sort t PgUp Help Files Check Spool PgDn Escape Restore gt From the Print Spool screen select Restore to display the Restore screen Note Restore appears as a command choice only if you define a retain directory on the Print Spool Description screen If Restore does not display on your screen verify that you defined a retain directory Restoring files from C SPOOLRET Spooling paused File State Form Class Prty Copies Size Date Time PAYROLL 003 BOND 1 2 1 10023 02 12 97 7 49 PAYROLL 002 CHECKS 1 5 6 7099 02 12 97 8 03 PAYROLL 001 CHECKS 1 5 1 13240 02 12 97 8 29 Select file using t and press Space to mark V to view or H to view header Ins restores files Del deletes files Sort Escape The message Spooling paused flashes in the upper right corner of the screen to remind you that all spool activity stops while you are using the Restore command When you return to the Print Spool screen a blinking arrow marks the first file in the files list Spooling remains paused so you can change file attributes for the restored file Spooling resumes when you finish changing attributes for the restored file and exit the files list The menu at the bottom of the screen lists the keys you can use You can sort files view files or spool headers mark files and delete files These operations are similar to ones you perform from the Print Spool screen Two operati
77. 68 88 h 88 16 BS A8 4D c8 C8 H E8 88 h 09 05 HT 29 5D 49 C9 I 69 89 i 89 05 HT A9 5D co co I E9 89 i 0A 25 LF 2a 5c 4A Dl J 6A 91 j 8A 25 LF AA 5C CA Dl J EA 91 j 0B 0B VT 2B 4E 4B D2 K 6B 92 k 8B 0B VT AB 4E CB D2 K EB 92 k oc oc FF 2c 6B 4c D3 L 6c 93 1 8C 0C FF AC 6B cc D3 L EC 93 1 OD OD CR 2D 60 4D D4 M 6D 94 m 8D 0D CR lap 60 cD D4 M ED 94 m 0E 0E so 2E 4B 4E D5 N 6E 95 n 8E 0E s0 AE 4B CE D5 N EE 95 n OF OF sI 2F 61 4F D6 O 6F 96 o 8F OF sI AF 61 CF D6 O EF 96 o 10 10 DLE 30 FO 0 50 D7 P 70 97 p 90 10 DLE BO FO 0 DO D7 P FO 97 p 11 11 DC1 31 F1 1 51 D8 Q 71 98 q 91 11 Decl B1 Fl 1 D1 D8 Q F1 98 q 12 12 DC2 32 F2 2 52 D9 R 72 99 r 92 12 DC2 B2 F2 2 D2 D9 R F2 99 r 13 13 DC3 33 F3 3 53 E2 73 A2 s 93 13 DC3 B3 F3 3 D3 E2 F3 A2 s 14 3C DC4 34 F4 4 54 E3 T 74 Ad t 94 3c DC4 B4 F4 4 D4 E3 T F4 a3 t 15 3D NAK 35 F5 5 55 E4 U 75 A4 u 95 3D NAK B5 F5 5 D5 E4 U F5 A4 u 16 32 SYN 36 F6 6 56 E5 V 76 A5 v 96 32 SYN B6 F6 6 D6 E5 V F6 A5 v 17 26 ETB 37 F7 7 57 E6 W 77 A6 w 97 26 ETB B7 F7 7 D7 E6 W F7 A6 w 18 18 CAN 38 F8 8 58 E7 X 78 AT x 98 18 CAN B8 F8 8 D8 E7 X F8 A7 x 19 19 EM 39 F9 9 59 E8 Y 79 A8 y 99 19 EM B9 F9 9 D9 E8 Y F9 A8 y 1A 3F SUB 3A 7A 5A E9 Z TA A9 z 9A 3F SUB BA 7A DA E9 Z FA A9 z 1B 27 ESC 3B 5E 5B AD 7B CO 9B 27 ESC BB 5E DB AD FB CO 1c 1c FS 3c 4c lt 5C E0 1c 4F 9c 1c FS BC 4c lt DC E0 FC 4F 1D 1D Gs 3D 7E 5D BD 7D DO 9D 1D Gs BD 7E DD BD FD DO
78. ASCII to EBCDIC table and two EBCDIC to ASCII tables The two EBCDIC to ASCII tables differ slightly The table differences allow you to use different translations for different devices For example you can use different translations on the printer and punch streams To help you distinguish between the two EBCDIC tables the tables are labeled table one and table two on your screen 310984 pue S 4 The BARR RJE default translation tables do not translate any control codes Instead BARR RJE substitutes question marks for control codes Translate control codes to Question marks is the default option If necessary you can alter the translation tables to suit your application by using the Translate control codes to Control codes option This option alters the following entries BARR RJE 49 00 1F and 80 9F of ASCII to EBCDIC Table One 00 3F of EBCDIC to ASCII Table One 00 3F of EBCDIC to ASCII Table Two See section 18 1 for more information about modifying the translation tables The tables in sections B 4 and B 5 show the ASCII to EBCDIC and EBCDIC to ASCII translations that are made when you select the Translate control codes to Control codes option The differences between Table One and Table Two are listed below each table The default tables used when you select Translate Control Codes to Question Marks are not shown in this appendix The differences between EBCDIC to ASCII Table One and EBCDIC to ASCII Tab
79. BARR RJE 456 Baud rate serial port 63 Begin Communication at Operation screen 317 322 Belgian character set 277 Binary 291 file format 454 interleaved with EBCDIC 291 receive mode 178 196 273 send mode 343 serial input 69 70 serial port data bits 64 Bind Data 375 390 description 391 BIOS key command 321 Blank lines convert 57 72 skip 57 72 Block Print reprint command 427 Borders on screen 202 Brazilian Portuguese character set 277 Buffer shortage console message 357 Buffers 802 2 statistics 380 381 Coax statistics 383 conventional memory 303 extended memory 304 SDLC statistics 377 X 25 statistics 384 XMS 377 C C Itoh printers 93 Cable null modem 498 problem 269 RS232 13 synchronous modem eliminator SME 298 458 testing 265 268 269 Cable specifications serial port 498 499 Call command JES3 484 Calling BARR RJE from an application program 25 455 Canadian French character set 277 Cancel input on serial port 70 output on host 334 Send Files command 344 Cancel command JES2 463 Cancel Previous Command screen 344 Card reader 11 457 Cardamation 451 input data from 70 154 Carriage control 12 490 ASA _ 183 184 187 188 439 converting to machine 187 188 439 discarding 178 184 fixed length records 184 ignoring 196 machine 181 184 187 188 none 184 not translated 273 override 477 S 370 receive mode 181 SCS 184 Carriage control stops characters 220 FCB 520 522 multiple instances
80. Barr software are not actually mounted with the combination of these three options This option prevents BARR RJE from displaying error messages that indicate a missing form See section 18 2 Tuning and Global Options Printer Control for more information about these options nm nm i 3 Eg i 3 f i 5 Other Ways to Obtain Form Name or Job Name If the HASP190 message cannot be enabled at your site you can use other options to obtain the form name or job name for display on the Print Spool screen BARR RJE 525 i E i 2 E L L If your jobs always include a banner page you can retrieve the form name or job name from the banner text You can use one of these options on the Assign Devices Options screen to obtain the form name or job name Output statement used in file Spool header from data See section 10 9 for more information about these options FA Using Edit Forms with Manual Mount Forms If you need file format information but cannot obtain it from the host you must define forms in the Barr software Additionally if the host cannot provide the form name for automatic forms mounting the PC operator must manually mount the Barr forms during program operation You can define Barr forms with the Printer Forms installation option When you define forms you assign each form a name and enter lines per form print lines per form lines per inch and carri
81. Destinatio Figure 8 1 Devices used with Barr software are either data sources or data destinations Data travels from sources to the Barr PC and from the Barr PC to destinations BARR RJE 51 n o 2 a 3 n rt Fq oa After you define source and destination devices from the Devices and Printers menu you can make device assignments on the Assign Devices screen described in Chapter 10 EFJ Devices and Printers Menu The Devices and Printers menu lists standard PC devices as well as some devices that are unique to the Barr software Devices used with any print option software you purchased are not included on this menu They display as separate items on the Installation Description menu Available print options include PRINT370 PRINT TWINAX BARR PRINT for LAT and BARR PRINT for TCP IP gt To reach the Devices and Printers menu select Devices and Printers LPT COM NET SEND LAN from the Installation Description menu Devices and Printers LPT1 Use Generic LPT2 Delete LPT3 Delete COM1 Delete COM2 Delete COM3 Delete com4 Delete SEND1 Use SEND2 Use LAN1 Delete LAN2 Delete LAN3 Delete LAN4 Delete NET1 12 send to network NOVELL Queues Escape receive from network Selection tlo This section briefly describes the devices on this menu Each device is described in detail in a separate section later in this chapter 52 8 2
82. Edit Forms table the software will attempt to load the BARR RJE 283 standard form STD If the STD form has not been defined BARR RJE uses the form from the previous job The SETUPHDR feature also must be enabled in the host definition so that PDIR information is included with each file received from the host For JES2 XA include the SETUPHDR parameter in the Remote Definition For JES2 ESA include the SETUP PDIR parameter in the Remote Definition For other systems you must set byte 3 of the LOGMODE s PSERVIC to 20 or 60 Also for JES2 you should change the work selection criteria for each printer stream to enable all files to be received automatically regardless of their form name or FCB name If you use SETUP PDIR FORMNAME eliminate F for form from the work selection criteria with the JES2 Set Printer command T PR1 WS F If you use SETUP PDIR FCBNAME eliminate C for FCB from the work selection criteria with the JES2 Set Printer command T PR1 WS C If SETUPHDR is enabled at the host or in the Barr software you cannot use the host FCBLOAD feature or the Use Barr FCBLOAD option a i A i o Although the mainframe file creation date and time are included in the PDIR record they are not used by the soft ware Instead when files are received they are assigned the PC date and time Operation screen The operator manually mounts forms with the Mount Forms command o
83. For more information about the required drivers see section 1 1 N o gt J Pej gt J amp m i 3 2 5 When the LAN support drivers are installed correctly the message displays the correct address of your network adapter BARR RJE 361 Notes i o a i Wu s c co rr N 362 21 7 Console Messages Communication Scope The Barr Communication Scope displays detailed information about communication between the PC and mainframe The Communication Scope can display the last 40 communications events When you begin communications on the BARR RJE Operation screen BARR RJE tries to connect with the mainframe and then log on For a dial up connection you can see dial up characters on the Communication Scope and logon error messages on the console Dial up scope characters display in white and logon error messages display in red After BARR RJE connects with the mainframe the remote goes into Normal Response Mode Snrm on the Communication Scope Then the mainframe and remote exchange frames of information Note Colors indicate whether the activity comes from the PC or the mainframe When BARR RJE sends a message to the mainframe green characters appear When BARR RJE receives a message magenta characters appear On a monochrome display and in this manual the sent message appears in normal text and the received message appears in AATFERTJ T
84. Hardware flow control option No Default XON XOFF flow control is not used Yes Some plotters and printers use XON XOFF flow control to prevent overrun on the data line when the printer or plotter is busy The XOFF character from the printer suspends output XOFF is the ASCII DC3 character and is coded as hexadecimal 13 XON resumes output to the printer XON is the ASCII DC1 character and is coded as hexadecimal 11 The flow control mechanism ignores the parity of XON and XOFF characters Interrupt request IRQ7 IRQ9 IRQ10 IRQ11 IRQ12 IRQ15 IRQ2 IRQ3 IRQ4 IRQ5 This option displays only for COM3 or COM4 Specify the interrupt request to use with the serial port Each COM port must have a different IRQ setting COM1 uses IRQ4 and COM2 uses IRQ3 If two COM ports are set to the same IRQ an error message displays Use this device as a data Source as well as Destination Data can be input to or output from a serial port When data is input the serial port is called a data source When data is output the serial port is a data destination Source and destination devices are discussed in sections 8 1 and 10 3 No Default The serial port is used only as a destination BARR RJE 65 Yes Data can be input on the serial port You can use a serial port as a source a destination or both You can route input from a serial port to any destination device and you can route output from any source device to a serial port
85. If you want each print file to use an overlay file specify this choice Use the next option Default overlay file to specify the name of the default overlay file If the default overlay file can be used for most files you can define fewer BARR RJE 289 overlay files Otherwise the default overlay file can be used to supply default information in case an overlay definition is accidentally omitted Default overlay file If the previous option Use default overlay file if overlay not found is set to Yes specify the name of the default overlay file Remember to create the default overlay file and put it in the overlay directory The standard form STD is a good choice for the default overlay name Suspend printing if overlay not found Choose whether to suspend the source device if a beginning overlay file is not found Usually the source device is an RJE printer such as PR1 This option does not apply if an ending overlay file is not found because ending overlay files are optional No Default Do not suspend the source device Use this selection if at least one of these conditions is true Beginning overlay files are not required for all print files a You have enabled the option Use default overlay file if overlay not found and defined a default overlay file a i A i o r Yes If a beginning overlay file is not found the source device is set to SUSPEND on the Assign Devices screen O
86. Initial Screens The first two installation screens display product information 1 To access the Installation Description type this command at the DOS prompt barrsnar i The first screen displays Barr Systems address phone number and software copyright information Installation Description Barr Systems Inc 800 BARR SYS P O Box 147015 352 491 3100 Gainesville FL 32614 7015 Dear Customer I trust this program meets with your expectations Our company depends on your support to develop quality software therefore please observe our copyrights We welcome your suggestions and will give immediate assistance to problems with our product Sincerely Tony Barr Programmer Copyright C 1983 1997 Barr Systems Inc Any key BARR RJE 47 Note If you cannot read the Any key prompt in the bottom right corner of the screen exit the software and type the mode bw80 command at the DOS prompt before continuing See Software Installation Steps in section 6 3 for more information about this command 2 Press any key to advance to the next screen BARR RJE Version 97A3 Product Options RJE SDLC The Installation Description configures the BARR RJE program fs tee o 77 oa amp T 72 The directions begin now Use the following keys to move around the screen gt The Enter key advances you to the next screen The Esc key restores the original
87. Note Before you disable the Installation Description make a backup copy of the BARRSNAR EXE program file You will not be able to view or modify the installation options in the copy of software in which the Installation Description is disabled Disable Receive mode in Assign Devices Select whether to disable the Receive mode option on the Assign Devices screen to prevent the PC operator from accessing this feature Receive modes are used to change the format of data 310 18 8 Session and Security Options received to the PC See section 10 8 for more information about receive modes No Default The Receive mode menu selection is not disabled The PC operator can view or alter the receive modes Yes The Receive mode selection is disabled and will not display on the Assign Devices screen You can set the receive modes before you disable the menu item Note Unless you also set Disable Installation Description to Yes the operator can re enable receive modes from the Session and Security Options screen Disable DOS session Choose whether to disable the BARR RJE DOS session This feature can be used to save PC memory and to prevent PC users from accessing DOS No Default The PC operator can access the DOS session if enough PC memory is available ob oo im gz i gt an Yes The DOS session is disabled This selection frees memory for other software features and prevents operators from reaching
88. The NetView host operator can issue a command to tabulate and graph the response time statistics NetView provides two types of alerts Both BARR RJE and RJE 3270 support these alerts For operator alerts the operator enters the alert message text on the Operator Alert screen The alert gets sent to the NetView program The host operator also can be notified depending on the priority assigned to the message Application alerts are sent to the NetView program when the remote workstation detects a data stream error For example a data stream error could occur if the host tries to write a 132 column screen on an 80 column 3270 display Application alerts include SNA state errors 20xx request errors 10xx and request rejects 08xx which BARR RJE displays as sense codes on the console For a list of possible sense codes and what they indicate see the sense codes and sense data for LU to LU Session Type 1 in the IBM publication SNA Sessions Between Logical Units N oo o Ej 3 D K Ss an o an BARR RJE 395 Response Time Monitor Screen Follow these steps to view the Response Time Monitor screen 1 Start at the Link Diagnostics Diagnostics menu Diagnostics Communications Statistics VTAM Commands Line Trace NetView Bind Data Escape Selection l gt 2 Select NetView The NetView screen displays NetView Response Time Monitor Operator Alerts Escape Select
89. The physical link between the PC workstation and the mainframe depends on which links your mainframe supports Chapter 2 in the Host Definition Guide describes the links BARR RJE supports Figure 3 2 shows the communication components between the PC workstation and the mainframe computer with an SDLC connection as an example BARR RJE 15 37x5 Front End Processor Mainframe o E S wi pu B o m m SDLC Telephone COMMUNICATIONS Line Figure 3 2 SDLC communication components between the mainframe and BARR RJE workstation As shown in Figure 3 2 a An RJE JES2 or 3270 application program communicates with VTAM a VTAM communicates with NOP a NCP communicates with a host modem The host modem communicates with the telephone line a The telephone line communicates with a remote modem a The remote modem communicates with BARR RJE The SNA protocol a layered communications protocol connects both 3270 and SNA RJE to the host The lowest SNA level is the Synchronous Data Link Control SDLC Data Link Control DLC ensures that frames blocks of data get sent correctly through an error recovery procedure If SDLC receives a frame incorrectly it asks for the frame to be re sent A frame numbering scheme ensures that SDLC receives frames in order with no missing or duplicate frames 16 3 1 Mainframe to Workstation Communication EFJ RJE and 3270 Workstations and Application
90. This example shows you how to define the Shift E1_ and Shift F2 function keys to include the prompt in place of the RJE print stream number It also includes a in the function key description The software makes no substitution in the description but the reminds you that the function key contains a prompt 1 From the Function Keys screen select Shift F1 to F10 The Shift Function Key Definitions screen displays 250 14 4 Defining Function Keys with Replaceable Parameters Shift Function Key Definitions F1 F2 F3 F4 F5 F6 F7 F8 F9 F0 _ gt nm 5 ix 5 A lt a Enter character 2 For Fi_ enter the description Set Form 1040 on Printer 3 Press to advance to the next line and enter the command T PR F 1040 4 For F2 enter the description Drain Printer 5 Press to advance to the next line and enter the command P PR The completed entries look like this BARR RJE 251 Shift Function Key Definitions F1 Set Form 1040 on Printer T PR F 1040 F2 Drain Printer P PR F3 F4 F5 F6 F7 F8 F9 F0 Enter character 2 gt x i oO Lu a When you press the Shift E1_ or Shift F2 function keys during program o
91. a a E ras o a Gr _ The menu options are described briefly below The following sections describe them in more detail Edit Forms Create or modify printer forms Mount Forms Specify which form to use with each RJE printer at software startup This operation is also called loading or mounting a form The forms you select here are used each time the software starts but forms can be changed manually or automatically during software operation Use this option to set up the initial form if you are manually mount ing forms from the Operation screen You also can use this option to mount an initial form when you are using the HASP190 or Power 1Q40A message Printer Forms Commands Sent to Host Specify commands to send to the host computer when a form is mounted in the software Use this option you mount forms manually from the Operation screen or automatically with the SHASP190 or Power 1Q40A messages Escape Return to the Installation Description menu FER Edit Forms You can enter up to 100 forms in the BARR RJE software If you need to define more forms a special version of the software is available which allows you to create up to 200 forms Contact Barr Systems to obtain the 200 forms version A form definition includes a form name plus format information The format includes lines per form print lines per form and lines per inch settings as well as carriage control stops Additionally
92. a Gr _ During software operation the forms will automatically display in alphanumeric order Scroll Feature for 200 Forms Option If you are using software with the 200 forms option you will see a scroll prompt Scroll gt near the top of the screen above the Escape selection Use this feature to display an additional page of 100 form entries Follow these steps to use the scroll feature 1 Use the or 4 keys to move the cursor to the scroll prompt 2 Put the cursor on the arrow that indicates the direction you want to move either to the previous screen or the next screen and press Enter Note that the prompt contains a vertical bar when you reach either the beginning Scroll gt or end Scroll gt of the list Format Information A format entry screen displays for each blank entry you select Edit Forms Name E Lines per form 66 Print lines per form 66 Lines per inch 6 Printer control 00 Enter character Name Enter a form name with up to eight characters The name you choose should match the form name used at the mainframe The form name for an RJE output file is specified by using job control language JCL in the mainframe program that produces the print output If you use SETUPHDR FORMNAME HASP190 FORMNAME or Power 1Q40A FORMNAME to automatically mount forms the form name you assign in the form definition must match the form name the host will
93. an External FAT File Initial Spool Printer Settings You can specify default spool printer settings on the Printer Initialization screen The settings on this screen control how spool printers select files to route and they take effect each time you start the software Print Spool Description Spool printers 1 SPOOL directory C SPOOL Retain directory Escape r uU 5 N 2 i D a ir e 3 Ej Advanced Spool Options File Attribute Table FAT Options Initial SPOOL Printer Settings Enter number gt From the Print Spool Description screen select Initial SPOOL Printer Settings Printer Initialization Printer State Form Class SPOOL1 Ready STD 1 SPOOL2 Ready STD 2 Choice You can change these fields on the Print Spool screen during spool operation but each time the software starts it resets the spool printer criteria to the initial values specified on this screen You can assign the following startup values The values for these fields must match a file s attributes for the file to print Printer The name of the spool printer displays in this column The number of printers that display on this screen depends on the number of spool printers you specified on the Print Spool Description screen BARR RJE 147 State This option sets the initial state of the spool printer at software startup You can specify a d
94. an S 370 channel printer 370 Channel receive mode is used only with the PRINT370 option purchased separately and is not valid for the Xerox 4235 printer Data is converted to variable length binary records using the Realia COBOL format This is different from the Binary receive mode Binary in this context means data can contain any character from 00 to FF ook A 2 2 5 S o D 2 Carriage control When you select the 9 370 Channel receive mode you are prompted to select the type of Carriage control normal Default BARR RJE uses the carriage control received from the mainframe This is the recommended choice Machine Use this choice when all jobs have a record format of FBM or VBM and the jobs do not print correctly with Carriage control normal Specify RECFM FB or RECFM VB in the JCL See your PRINT370 manual for more information about 370 Channel receive mode especially for details about replacing a Xerox 871CM with the PRINT370 product Transparent BARR RJE does not change the data Some applications require unaltered data The received data might not have the exact format it did on the host computer because the RJE system might have processed it during transfer from the host Transparent receive mode is valid only for SCS type data streams namely data from SNA RJE 3287 3270 LU Type 1 requires RJE 3270 5250 printers requires PRINT TWINAX and XPAF print streams For example you need to
95. and Global Options Printer Control screen See section 18 2 OUTPUT Statement Error If you include form name in the OUTPUT statement but a user defined form is not found in the Barr Edit Forms table the software displays this message OUTPUT statement received but form nnnnnnnn not found The form name in the spool header is set to blank but other OUTPUT statement fields are applied See section 10 9 for more information about the OUTPUT statement 360 21 7 Console Messages Serial Port Input Errors If an error occurs while data is being input on the serial port the software displays this message on the console Input from COM1 lost a is substituted for lost character See Error Handling for Serial Input in section 8 4 for more information TCP IP LPR UNIX Print Queue Activity If you use a NET device to write to a TCP IP LPR UNIX print queue and file transfer is interrupted you might see this message File canceled or incomplete See section 8 5 for more information about TCP LPR UNIX print queues Token Ring Address Error If you select 802 2 token ring for your communication link you might see this error message Using Token Ring Address 00000000 If the token ring address displays as all zeros it indicates that BARR RJE cannot determine the token ring address of your network adapter Verify that the LAN support adapter drivers are installed The drivers are supplied by your adapter vendor
96. and Printers menu as described in section 8 9 See section 21 4 for more information about the Send Files command KEYBOARD You can send commands you type at the PC keyboard to the host computer with the assignment KEYBOARD gt COMMAND Use the Command to Host option on the Operation screen to enter commands as described in section 21 2 The keyboard device is enabled automatically You can disable it by setting KEYBOARD NUL but you cannot remove it from the Assign Devices screen COM1 COM4 You can input files on a PC serial port The software inputs data automatically when it detects files For example you can attach a card reader or a VAX computer to the PC COM1 port to input files You can also use serial ports as destinations You can enable the COM devices from the Devices and Printers menu as described in section 8 4 154 10 3 Source and Destination Devices CON Console messages for the remote PC operator originate from the host computer or from the Barr software Usually you direct these messages to the PC screen by setting CON SCREEN As soon as messages are detected they display at the bottom of the console portion of the Operation screen As new messages display older messages scroll off the screen See section 21 7 for more information about the types of messages that display The console device is enabled by default You can disable it by setting CON NUL but you cannot remove it from the Assign Devices scr
97. and remove it from the Assign Devices screen The word Delete displays next to the queue name on the Novell Queue Devices screen Yes Enable the device and display it on the Assign Devices screen File server of queue Enter the name of the file server on which the queue is located The queues can be located on the same file server or different file servers n o 2 E a 3 G a a Fq oa Queue to service Enter the name of the queue to be serviced by the Barr software Queue Server Options The Barr software acts as a queue server on the network to access the Novell queues You must specify a server name and password so the software can log into the necessary file servers When you select Queue Server Options the following screen displays Queue Server Options Queue Server Name BARRQSERVER Queue Server Password BARRPASSWORD Enter character Queue Server Name Enter the server name assigned to the BARR RJE software This name is used to access the Novell queues Queue Server Password Enter the server password BARR RJE uses the password to access the Novell queues 116 8 11 NOVELL Queue Devices Support for Forms and Multiple Copies BARR RJE supports printing multiple copies of files received from Novell NetWare queues If files are received to disk or to the print spool their Novell job information can be copied to the Barr spool hea
98. and retries the path If the software cannot resolve the path it suspends the source device The software does not change the Beginning of file name in this case If the software encounters a path error when Ending of file name is set to formname jobname or jobname formname it omits the form name or job name from the path If the software cannot resolve the path it suspends the source device In each of these cases the software also displays a console message to alert you to the error For example you might see this message if you leave the file name blank ERROR file name is blank File name changed to You can disable these messages from the Tuning and Global Options Display and Disk Options screen 172 10 5 Assigning a File as a Destination EIX Logging Console Messages Assignment Steps You might want to see console messages on the screen while you use BARR RJE and have a log file of the messages for later reference To create a log file assign LOG FILE on the Assign Devices screen You can assign any name to the log file If you name it CONSOLE LOG the file will be easier to identify See section 21 7 for more information about console messages _ A 2 5 i S5 o 7 Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PU1 SUSPEND SPOOL1 LPT1 Select SOURCE DESTINATION Escape Selection t 7 1 From the Assign Devices
99. automatically sends the logon information to the host at program startup Remote Console for MVS JES VM RSCS and VSE POWER Commands Operator commands are a valuable management device You can use commands to oversee job status selectively release jobs for execution specify special forms on the printer suspend printout of a job and select and release jobs for printing You also can recover from paper jams easily by telling the host to back up and reprint BARR RJE 23 With BARR RJE the operator can send commands to the host job entry system from the PC keyboard Command responses display on the BARR RJE console Appendix A lists the most common MVS JES2 operator commands Unattended Operation an gt 2 ras wi gt es n cc cc lt a BARR RJE supports unattended program startup and automatic program restart Unattended startup allows the software to automatically begin communications at a specified time For example at the end of the day you can leave the PC and printer on You can set the software to dial the host and receive print output when telephone rates are lower or you can set the software to automatically answer a call from the host at a specified time Automatic program restart reduces the number of times operators must intervene to restore communication with the host BARR RJE automatically restarts the logon process when it receives the SDLC Set Normal Response Mode Snrm comman
100. but BARR RJE discards carriage control information Binary receive mode often is used when the received data will not be printed This type of data usually is received from a mainframe punch PU1 A common application is to assign PU1 TAPE and Binary receive mode when you receive data to magnetic tape TAPE displays as a destination only if you purchased the BARR TAPE option When you receive data on a punch device records are padded with blanks to the host punch width Data received on a print stream PR1 is not padded Additionally when you receive data on the punch stream if the last line of a file contains only blanks the line is deleted This removes the extra blank line JES2 adds to punch stream output N ASCII lines A method for receiving files with fixed length records longer than 80 characters Fixed length records are records of equal length Some host systems can transfer only 80 character records and N ASCII lines lets you work around this limitation For records that are not an even multiple of 80 characters or have a length greater than 720 characters Variable ASCII lines might be a better choice 178 10 8 Receive Mode To use N ASCII lines you must write a mainframe program to divide each dataset record into groups of 80 character lines Each record must be divided into the same number of lines from 1 to 9 so that all records have the same length When the 80 character lines are received to the PC the sof
101. by the previous option Control spool with controls spool printing The value you select for the Control spool with option affects the wording for this option The display name appears in the first column of the Print Spool screen immediately before the file name This column also is called the display column The display column heading matches your selection for this option 126 9 4 Advanced Spool Options No Default Only the name specified with the Control spool with option displays on the Print Spool screen When a file prints the printer name for example LPT1 displays in the first column and the word Printing displays in the state column For example if you select Form name for Control spool with and set Display FCB name on spool control screen to No the Print Spool screen looks like this Printer LPT1 LPT1 File State Form QTR RPT 001 Printing REPORT QTR RPT 001 Printing REPORT QTR RPT 002 REPORT IN STOCK 001 REPORT PAYROLL 004 BOND SALES 004 INVOICES Printers Sort Files Check Spool Class 1 1 1 1 1 2 Prty 5 WW UU UI Copies Size Units Status 1 246281 0 busy Date Time 1 246281 10 02 96 14 47 1 236841 10 02 96 14 49 1 500601 10 02 96 15 06 1 3 o m 5 i i D a ir e 3 Ej 16623 10 03 96 8 50 13240 10 03 96 8 50 Help Escape Yes Both the form name and FCB name display on the Print Spool screen
102. can switch to a DOS session and use DOS features during BARR RJE operation You can then perform other tasks while BARR RJE simultaneously sends files and receives output A o gt pes gt e a m n oO 2 oO a If you have a color video adapter BARR RJE uses color to increase software screen and message readability Automatic Configuration BARR RJE automatically allocates PC memory When the software starts it determines how much memory is available and automatically assigns free memory space for program buffers The software also automatically determines whether you use a monochrome or color video adapter and the numbers and addresses of PC parallel and serial ports You specify device assignments from the Installation Description menu When you start the software BARR RJE automatically performs logon operations and readies all devices Autodial for Modems BARR RJE can instruct an external modem to dial the host computer automatically You can even schedule the autodial for late at night when telephone rates are low You enter dialing instructions on a screen in the software where BARR RJE permanently stores them Contact Barr Technical Support for information about using external modems Automatic Logon You enter logon information from the Installation Description menu BARR RJE stores the information in the software so you do not need to re enter it each time you communicate with the host BARR RJE
103. character ok N 2 D 3 5 a 2 o 5 77 Phone numbers Enter the host computer s phone number You can enter up to three phone numbers although most situations require only one The software uses the second number only if you do not successfully connect with the first number The software tries the third number only if the second number did not successfully connect These characters are valid for the phone number and modem dialing instructions Character Function 0123456789 Dial digits Touch tone digits gt Modem dependent function Wait for dial tone or wait several seconds usually the modem default of 2 or 5 T Use touch tone dialing default P Use pulse dialing space You can use parentheses dashes and spaces to make the phone number readable in a conventional format The software ignores these characters Example 1 Typical Long Distance Phone Number This example shows a typical long distance phone number BARR RJE 205 Phone numbers 1 352 555 1234 Example 2 Calling Long Distance from a PBX System If you have an internal phone system such as a PBX you might need to specify additional digits in the phone number Additional digits might include a code to reach an outside line or a billing code for accounting purposes This example uses a PBX code of 9 to 2 reach
104. computing It creates a computing envi ronment in which users appear to have their own IBM 370 computer VM RSCS Virtual Machine Remote Spooling Com munications System VSE POWER An S 370 operating system program that simultaneously operates many readers printers and remote communications devices VTAM Virtual Telecommunications Access Method An IBM operating system pro gram that resides on the mainframe con trolling SNA communications between the mainframe applications software and re mote terminals X 21 An International Telegraph and Telephone Consultative Committee CCITT recom mendation for a general purpose interface between data terminal equipment and data circuit terminating equipment for synchro nous operations on a public data network X 25 An International Telegraph and Telephone Consultative Committee CCITT recom 548 Glossary mendation for a general purpose interface between data terminal equipment and packet switched networks Xid In SNA communications an SDLC command and response passed between a host and remote that provides initial identification of the remote to the host Contains IDNUM and IDBLK data XON XOFF A control character used to restore XON or suspend XOFF the flow of data XPAF Xerox Printer Access Facility BARR RJE 549 Messoj9 Glossary Notes 550 Glossary Index file name character 172 send files command 344 f
105. default copy count of 1 is assigned After it prints the file gets deleted 142 9 5 File Attribute Table FAT a Any file named PAYROLL is assigned Priority 9 the highest priority The file is retained after it prints unless its spool header already contains Disposition Delete a Any files whose attributes do not match those listed in the match columns are put on hold and assigned Class A and Priority 5 The file is retained after it prints unless its spool header already contains Disposition Delete When you finish making table entries press to return to the Print Spool Description screen EYJ Maintain an External FAT File This section tells you how to create and edit the external FAT file You need to create an external FAT file if you set Type of FAT table to external on the File Attribute Table FAT Options screen After you create the external FAT file test it according to the instructions in section 24 8 Memory Requirements for Table Entries Before you begin making external FAT entries check that your PC has enough memory to load the number of entries you need The number of entries the external FAT can hold is limited only by the amount of extended memory XMS available on your PC To estimate the amount of XMS required for the external FAT multiply the number of entries by the maximum number of bytes per entry For example if you use Filename Jobname for the match criteria and need 1 500 table entries
106. eee eee 316 Copying the Configured Software 000 317 Using Configuration Files 0 000 00000008 318 BARR RJE Startup aa ete eee eee 321 Starting BARR RJE 0 cee ee eee eee 321 From the BARR RJE Installation Description Screen 321 From the DOS Prompt 00 0 0 c eee eee eee eee 322 When You Power on the PC 00 0 eee eee eee 322 With Different Configuration Files 00 322 Monitoring the Connection Process 0 00000 323 Communication Scope 0 0 0 cee eee eee eee 323 Status LAT Soni Sti erae E tad r OE E dee phon naam ates 323 Console e s wisdvers phoresis AN bth conde Aen ale Seo ele Noles hilo 326 Monitoring the Logon Process 0 000 000 ee 330 BARR RJE Operation 2 0 0 0 00 e cece eee eee 333 Command Menu 0 eee cece eee 333 Command to Hostina aerie ae heat teats saan apa a di eteon adie wih da 335 Typea Commands os ie ces sei siya yal ge gues tp aa ata 335 Use a Predefined Function Key 0 0 000004 336 Command to Host Example 0 0000000002 eee 336 QUES SS ween ct detec Deda andes tt a weenie reas gay dated tena ee 337 Sem ENES ig dea dear sees Sake tak aaa dead edd an TA 338 Send Files with the Send Files Commands 338 Steps for Sending Files ea nre nat cee cee cee ee ee ee ee 339 Send MOdeS sa Ti aen aa E Re ian okie Pome des 342
107. expects to receive frames in a timely manner usually within 3 seconds Indicated by a H or M on the Communication Scope frames aborted Number of aborted frames received by BARR RJE Indicated by an IN on the Communication Scope equipment errors Count of equipment errors caused by any of the following N oo o Ej 3 9 K Ss an o an Receive overrun An d on the Communication Scope Transmit underrun An 4 on the Scope Transmit timeout An on the Scope Usually caused by missing clock m Missing CTS A on the Scope Page 3 X 25 Frame Level Statistics gt Press to advance to page 3 BARR RJE 385 an o S a D lt a E E oO oc N X 25 Frame Level Statistics Info 0 0 Sabm Ua 0 0 RR 0 0 Disc Dm 0 0 RNR 0 0 Frmr 0 0 REJ 0 0 Uns F bit 0 page 3 next page reset Any key These are statistics about the types of X 25 frames sent and received Frames sent display in green in the first column Frames received by the PC display in magenta in the second column These frame types indicate errors Frmr Number of frame rejects sent or received This error should not occur during normal operation If the link is lost and the value here is not 0 contact Barr Technical Support and supply a line trace Uns F bit Unsolicited F bit received from the host This error should not occur during normal operation If the link is lost and
108. express written permission of Barr Systems Barr Systems has the legal right to trace serial numbers and to take legal action if these conditions are violated Limited Warranty THE LICENSED SOFTWARE AND THE PRODUCT HARDWARE ARE PROVIDED AS IS ALL WARRANTIES AND REPRE SENTATIONS OF ANY KIND WITH REGARD TO THE LICENSED SOFTWARE AND THE PRODUCT HARDWARE ARE HEREBY DISCLAIMED INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EXCEPT THAT BARR SYSTEMS WARRANTS THAT THE LICENSED SOFTWARE AND THE PRODUCT HARDWARE WHEN DELIVERED WILL OPERATE SUBSTANTIALLY AS DESCRIBED IN THE USER DOCUMENTATION OR GUIDE UNDER NO CIRCUMSTANCES WILL BARR SYSTEMS BE S 2 E S 528 Warranty Information LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL SPECIAL OR EXEMPLARY DAMAGES EVEN IF APPRISED OF THE LIKELIHOOD OF SUCH DAMAGES OCCURRING LICENSEE S SOLE AND EXCLUSIVE REMEDY FOR THE BREACH OF ANY PROVISIONS OF THIS AGREEMENT OR FOR BREACH OF WARRANTY SHALL BE LIMITED TO THE REPAIR OR REPLACEMENT OF THE LICENSED SOFTWARE OR THE PRODUCT HARDWARE BY BARR SYSTEMS OR THE REFUND OF THE PURCHASE PRICE THE CHOICE OF REMEDIES SHALL BE MADE AT THE OPTION OF BARR SYSTEMS Licensee and Barr Systems agree that the Licensed Software and the Product Hardware are not intended for use by Licensee as consumer goods under state or federal law This warranty gives you specific legal
109. features such as the print spool or LAN connections to continue to operate without accruing additional communications charges Reconnect periodically Specify whether BARR RJE will automatically reconnect at specified time intervals after it disconnects This feature is useful for unatten ded operation It allows you to avoid communications charges when the line is idle but allows you to periodically check for file activity This option is valid only if Exit from program after disconnect is set to No a i A i o r No Default The software does not attempt to reconnect unless the PC operator issues the Connect Link command from the Quit menu Yes The software reconnects at the specified intervals Reconnect time interval If Reconnect periodically is set to Yes specify the interval at which the software should reconnect The time interval is specified in hours and minutes For example to reconnect at one hour intervals specify 1 00 After BARR RJE disconnects the following messages display on the Operation screen until the next reconnect time 302 18 5 Restart Actions EEX Trace and Memory Options Waiting until hh mm to start communication Current time hh mm Reconnecting Enable FNA Termination Sequence When BARR RJE connects to a mainframe running the Fujitsu Network Architecture FNA use this option to control the connec tion termination sequence If the termination
110. for the File Server and Print Queue fields on the Network Printer Options screen m The source device is set to SUSPEND and an error message displays on the Barr console This is the same action that occurs after a disk write error For this error handling method the File Server and Print Queue fields on the Network Printer Options screen must be blank When a device is set to SUSPEND the operator must correct the error from the Assign Devices screen Change the destination from SUSPEND to a NET device that does not use the FCB FORM to Print Queue Translation Table or to a NET device that has a default File Server and Print Queue When the file finishes printing change back to the original destination to resume normal file routing co i D S o D i 2 Ss es mr Ss o a NET Options The NET Options screen contains options that affect all NET devices NET Options User name Password SPOOLn NETm Options Retry wait time 5 minutes zero to disable Decrease file priority on retry No Enter character User name Password A User name and Password BARR RJE uses to connect to file servers You can use only one Username and Password to log into all the servers When you enter a password asterisks display for the password characters BARR RJE uses a keyed login to allow login on servers restricted to encrypted passwords BARR RJE 89 During BARR RJE operation
111. form feeds FF to indicate page boundaries The record length must include two bytes for the CR LF Usually this type of data will not be printed ASCII variable Data is converted from EBCDIC to ASCII Records can have a variable length Although records are not padded any trailing blanks at the end of a record are deleted The ASCII data includes carriage return and line feed pairs CR LF to indicate record boundaries but does not include form feeds FF to indicate page boundaries Usually this type of data will not be printed _ A 2 5 S o 7 Retired mode Not used The receive mode at this location was removed This option serves as a place holder to enable configuration files from older versions of Barr software to remain compatible EBCDIC variable Data is received as variable length EBCDIC records This mode prevents binary data from being padded with blanks when records shorter than 80 characters are received on the punch stream EIE Options for Assign Devices When you make device assignments you can choose from several options The available options display when you select Options from the menu line at the bottom of the Assign Devices screen Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PU1 SUSPEND SPOOL1 LPT1 Continue Escape Receive mode Options Help gt Select Options BARR RJE 185 4 2 gt 7
112. format BARR RJE sends data as 80 byte records without carriage control BARR RJE does not translate the data Tn Transfer files Use this send mode to transfer files PC to PC or remote to remote as described in section 26 2 Or use it to transfer files between the PC and the host with the BARR TRAN mainframe program as described in the BARR TRAN manual V Variable ASCII lines Each ASCII line is sent as one or more 80 character lines You can use this send mode to send files that contain variable length lines or lines with more than or less than 80 characters BARR RJE adds a vertical bar to signal the end of the original record You must use a program at the host to rebuild the lines into their original records 1 9 N ASCII lines Use this send mode to send fixed length lines that contain an even multiple of 80 characters For records that are not an even multiple of 80 characters or contain more than 720 characters Variable ASCII lines V is a better choice BARR RJE sends each ASCII line as n lines of 80 characters where n is a number from 1 to 9 You must use a program at the host to rebuild the specified number of lines into their original records N _ o gt eoj ps J amp m i 3 2 5 Example Binary Send Mode This example shows how to send several files with send modes Each send mode you specify applies to only one file To send a JCL file in ASCH format concatenated with two data files
113. gt ACTLU 2D 00 08 00 9D_46 6B 80 00 0D 02 01 lt ACTLU 2D 00 00 08 9D_46 EF 90 00 80 04 00 00 OD 2 gt ACTLU 2D 00 09 00 9D_47 6B 80 00 0D 02 01 lt ACTLU 2D 00 00 09 9D_47 EF 90 00 80 04 00 00 OD 2 gt ACTLU 2D 00 0A 00 9D_48 6B 80 00 0D 02 01 lt ACTLU 2D 00 00 0A 9D_48 EF 90 00 80 04 00 00 0D 2 gt ACTLU 2D 00 0B 00 9D_49 6B 80 00 0D 02 01 lt ACTLU 2D 00 00 0B 9D_49 EF 90 00 80 04 00 00 OD 2 gt FMD SSCP 2C 00 02 00 00_01 03 80 00 15 D5 C5 D9 C4 C3 40 E5 E3 C1 D4 40 C9 E2 40 C1 C3 E3 C9 E5 NERDC VTAM IS ACTIV C5 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 E 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 E3 C5 C4 F1 E3 C2 FO FO TED1TB00 15 gt FMD SSCP 2C 00 03 00 00_01 03 80 00 15 D5 C5 D9 C4 C3 40 E5 E3 C1 D4 40 C9 E2 40 C1 C3 E3 C9 E5 NERDC VTAM IS ACTIV C5 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 E 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 E3 C5 C4 F1 E3 C2 FO F1 TED1TB01 15 gt INITSELF 2C 00 02 00 00_01 8B 80 00 01 06 81 a lt INITSELF 2C 00 00 06 00_01 0B 80 00 01 06 81 00 C2 C1 E3 C3 C8 40 40 40 F3 08 D5 C5 D9 F1 D1 C5 a BATCH 3 NERIJE E2 F2 00 00 0B D9 D4 E3 F1 F2 F2 6B 6B C2 E2 C9 82 RMT122 BSI lt FMD SSCP 2c 00 00 02 00_01 83 80 00 lt FMD SSCP 2C 00 00 03 00_01 83 80 00 Figure 23 1 A line trace can help Barr Technical Support diagnose problems BARR RJE 389 N
114. has three distinct parts 1 Spool Printers List of printers assigned to the print spool and their printer attributes 2 Spool Files List of files to be printed and their attributes 3 Command Menu List of the available spool commands Column headers identify printers files and their attributes The rest of this chapter describes how to use features of the Print Spool screen to manage your print files m o 5 i i 72 pan i Q N Steps for Printing Files Typically you will print files in batches according to the forms paper they require When you are ready to release files for printing follow these basic steps 1 Review the list of files on the Print Spool screen and decide which form to print next 2 Load the corresponding forms paper on the printer 404 24 1 Managing Print Spooling 3 Use the Printers command to change the spool printer s form attribute and then press Enter Repeat these steps for each spool printer you have defined How the Print Spool Selects Files for Printing When a spool printer is available the print spool selects files based on their attributes A file is eligible for selection if these conditions are met The file s state is Ready The file s form name matches the printer s form name The file s class matches the printer s class Files print in the same order as they display You can control the di
115. helps you identify who submitted the file The user ID is added to the LPR LPD control file that is sent with the print file and is required by some LPDs Add form feed between jobs Specify whether to add a form feed FF between jobs for easier job separation Yes Default Insert a form feed between jobs to separate jobs with a blank page No Do not add a form feed between jobs Use for print queue name Specify the print queue to which BARR RJE will route output Three choices are available name entered above Default Use this choice if you will direct all output for this NET device to only one print queue on a file server as specified by the Print server address and Print queue fields 84 8 5 NETI NET12 Devices FCBNAME FORMNAME You can route output to any print queue on any file server according to the FCB name or form name specified in the file When you choose either FCB name or form name the FCB FORM to Print Queue Translation Table screen displays The translation table associates the FCB name or form name in the file with a file server and print queue The software routes files to the LPR queues specified in the table To include the FCB name and form name information in the file you can use the normal host means of specifying the FCB name and form name usually the HASP190 message or SETUPHDR record the Barr OUTPUT statement used in file option or the Barr Spool header from data option provides f
116. instructions in the same language to replace it The macro can also specify values for parameters in the replacement instructions mainframe computer Term used for a large central computer that offers a full set of computing services The term originated in the days when the central processor memory and input output channels were located in one central housing called the mainframe Messoj9 BARR RJE 541 Mb Megabit MB Megabyte megabit One million bits more accurately 1 048 576 bits megabyte One million bytes more accurately 1 048 576 bytes message The longest unit of information trans mitted as a consecutive series of bits In asynchronous communication a message is a single character In synchronous communication a message is a block of characters preceded by some sync charac ters and terminated by an end of block marker MLU See multiple logical unit RJE MODEENT In SNA communications the macro that defines the LOGMODE table modem Modulate Demodulate A device designed to interface between a digital communica tion link and an analog communication link Usually the digital communication link is a computer or terminal and the analog communication link is a telephone line Modulate means convert a digital signal from the computer into an analog signal capable of being transmitted by the telephone system Demodulate is the opposite of modulate MODETAB In SNA communications a t
117. is 9 The completed screen looks like this located in the F ACCTING directory in this example Press to store the entry for F2 254 14 5 Using Function Keys with Send Files Commands Ctrl Function Key Definitions F1 Send DAILYRPT on SEND1 Hc dailyrpt F2 Send PAYROLL on SEND2 2 accting payroll F3 F4 F5 F6 F7 F8 F9 F0 _ gt nm 5 ix 5 A lt a Enter character 10 When you finish entering definitions press to store the last command Then press to return to the Function Keys screen 11 To verify that you stored the new definitions select Ctrl F1 to F10 and review your changes on the Ctrl Function Key Definitions screen 14 6 Options You can specify other options that affect how you enter commands to the host on the function key Options screen gt From the Function Keys menu select Options The Options screen displays Options First character of command sent to host __ Disable console commands No Enter character You can specify the following options BARR RJE 255 gt amp x i oO Lu a First character of command sent to host Commands for the host computer begin with a command character for example JES2 commands begin with a You can specify the beginning command character so you do not
118. it to LPT1 6 Select PR2 and assign it to LPT1 The Assign Devices screen displays the new assignments Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND COM1 LPT1 CON SCREEN LOG NUL PR1 SPOOL PR2 LPT1 PU1 SUSPEND SPOOL1 LPT1 Continue Escape Receive mode Options Help The software alternates between the two sources the VAX COM1 and the IBM mainframe PR1 looking for files to send to the shared printer When a file from the VAX is input on COM1 the data is directed to the printer attached to LPT1 When the VAX job finishes the software checks for input from the mainframe computer on PR1 Any data input on PR1 is directed to LPT1 and then the process repeats If you need to send large amounts of data from the VAX to the Barr PC the BARR PRINT for LAT option might be a better solution than the serial port With BARR PRINT for LAT you can receive data to the PC from up to eight VAX ports from one or more VAX computers Also data transfer is faster with BARR PRINT for LAT than it is on a serial port BARR RJE 195 TRE Plot Output Assignment On the host computer you can run programs to produce plot output and then direct the plot output to the PC as RJE printer or punch files In the Barr software you can assign plot output to write to a file on disk by using the destination FILE or to write to a plotter connected to a serial port by assigning a destination of COM1 When you rec
119. job name and FCB name fields Filename Job Formname FCB Dispos When you match by Filename Jobname you do not use the FCB name field and the form name becomes an override field Filename Jobname Formname FCB Dispos When you match by Filename FCBname you do not use the job name field and the form name becomes an override field Filename Job Formname FCBname Dispos Entry Lines All lines that follow the header line are FAT entries Follow these guidelines when you make table entries BARR RJE 145 Entry Delimiter The ASCII carriage return character represented as a hexadecimal 0D defines the end of each line Press to insert this delimiter after the last field you enter on each line Ignored Characters Within an entry the software ignores extra spaces and tabs between fields Use these characters to align fields within columns You also can insert blank lines to make the file more readable because the software ignores blank lines between entries Field Separator You must use commas to separate fields If a field is empty use a comma as a place holder Be sure to align the comma in the correct column Because the last field you enter on each line is followed by the ASCII carriage return you do not need to insert a comma separator after the last non blank field or use comma place holders to fill unused columns that follo
120. lines selection lets you work around this limitation If records are an even multiple of 80 characters 160 240 and so forth N ASCII lines might be a better choice With the Variable ASCII lines selection BARR RJE receives 80 character records from the host and rebuilds them to their original lengths The EBCDIC data from the host is converted to ASCII format with a carriage return and line feed CR LF to indicate the end of each record but no form feeds FF are added to indicate page boundaries BARR RJE 179 To use this feature you must write a mainframe program to divide all records into 80 character lines If the record length is not an even multiple of 80 the last line for the record can have less than 80 characters The mainframe program must insert a record indicator at the end of each record The EBCDIC vertical bar or hexadecimal 4F is the default delimiter You can change the delimiter character with the Variable record length delimiter option under Tuning and Global Options Miscellaneous Options For example you would divide a 120 character record into two parts an 80 character line and a 40 character line that ends in a vertical bar When the data is received to the PC the software rebuilds each record by combining lines until it encounters a vertical bar The software discards the vertical bar and any blanks the RJE system added to pad the last portion of the record to 80 bytes For the MVS JES2 MVS JES3
121. local area network LAN A high speed communications network within a limited geographic area Typical ly several PCs are linked together within a single building or campus In contrast a wide area network might span hundreds or thousands of miles locally attached Directly connected to the mainframe without use of a telecommunication line logical unit LU In SNA communications an independent stream of data that is multiplexed with other streams within a physical unit LOGMODE In SNA communications a list of param eters specifying the type of session to establish between a mainframe application and a remote workstation VTAM uses the LOGMODE during the Bind operation logoff In SNA communications to terminate a session logon In SNA communications to initiate a session or to initiate a session between an application program and a logical unit logon data In SNA communications a logical unit sends a message in response to the logon The entire logon sequence or message is called the logon data loopback A testing procedure in which transmitted data is returned as received data LPD Line printer daemon The remote printer server that allows other hosts to print on a printer local to your host LPR Line printer request LPT1 LPT2 LPT3 PC parallel ports 1 2 and 3 LRECL Logical record length LU See logical unit macro An instruction in a source language that points to a sequence of
122. log on to the mainframe EAE Send Files You can use the Send Files commands to send files to the host or another device You can also send files by using an embedded command the software startup command function keys or LAN connections Send Files with the Send Files Commands Two Send Files commands enable you to transfer files from your PC to another device These commands reflect the destinations assigned to SEND1 and SEND2 on the Assign Devices screen The default destinations for SEND1 and SEND2 are RD1 and SCREEN respectively You can change the destinations during software operation or from the Installation Description The assignments you make from the Installation Description are used each time the software starts See Chapter 10 for more information about the Assign Devices screen For example you can change the SEND1 and SEND2 destinations to RD2 and PROE on the Assign Devices screen CENTRAL HOST NAME COMMUNICATION SCOPE 0 0 LPT1 0 busy LPT2 0 normal 16 48 14 i o a i Wu c gt s c co rr N SEND1 RD2 SEND2 gt PROE KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PU1 SUSPEND SPOOL1 LPT1 Select SOURCE DESTINATION Selectiont gt BARR RJE updates the commands on the Operation screen to reflect the new destinations 338 21 4 Send Files CENTRAL HOST NAME COMMUNICATION SCOPE 0 0 LPT1 0 busy LPT2 0 normal 16 48 14 Opera
123. lt a Print Spooling Print spooling manages printing files on one or more printers BARR RJE print spooling for the PC is similar to mainframe print spooling BARR RJE organizes print files in a print queue which is a directory on the PC hard disk It assigns one or more printers for print spooling The print spooler automatically prints the files on the available printers according to user controlled selection criteria such as form class and priority Plotter Support BARR RJE produces plots without requiring operator attention You can print plots more economically in batch than in a conversational time sharing environment that requires the operator to stand by the plotter The host computer concurrently sends host produced plot files to the PC with other data streams and passes them through to a plotter attached to a serial port EFJ Ease of Operation Features The following features simplify and extend BARR RJE and thus make the software easy to learn and simple to operate Menu Driven Operation BARR RJE menus guide you through each stage of software installation and operation You position the cursor and press to select an option or proceed to a new screen During operation operator instructions prompts and messages notify you about special conditions and alert you when you need to take action 22 4 2 Ease of Operation Features Simultaneous Use of DOS and BARR RJE Full Support for Color Display You
124. m You are using the PRINT370 option to print to an S 370 channel attached printer SETUPHDR is preferred over FCBLOAD for channel attached printers because of a host limitation in the way carriage control stops are processed for remote printing This limitation is explained under Remote vs Local FCB Handling in section F 3 Enabling the SETUPHDR Feature Follow these basic steps to enable the SETUPHDR feature 1 Enable SETUPHDR at the host computer nm nm i 3 S i 3 i i 5 2 Enable Mount forms by in the Barr software 3 Create the Barr form BARR RJE 517 1 Enable SETUPHDR parameters at the host computer First enable the SETUPHDR parameters For most operating systems you enable SETUPHDR with only by the PSERVIC parameter For MVS JES2 you also must define the SETUPHDR XA or SETUP PDIR ESA parameter in the Remote Definition a PSERVIC parameter PSERVIC the LU Presentation Services profile is defined in the VTAM Logon Mode Table Entry or LOGMODE Chapter 1 of the Barr Host Definition Guide discusses the LOGMODE and corresponding PSERVIC parameter for your operating system u SETUPHDR parameter To enable the SETUPHDR feature for MVS JES2 the host programmer must enable both the PSERVIC parameter in the LOGMODE as discussed above and the SETUPHDR parameter in the Remote Definition For JES2 XA specify the parameter SETUPHDR on the Remote Definition RMTnnnn statement For JE
125. messages are self explanatory This section describes the most common console messages The console log file includes messages from the host commands sent to the host diagnostic messages from the Barr software and other program activity Console Features The console includes a message time stamp and color coding to make messages more readable You also can control the rate at which messages move up and off the screen 352 21 7 Console Messages File Viewing Utilities You can use a file viewing utility to view the console log file from a DOS session or another node on the LAN while the software is operating The LIST program from Buerg Software allows you to view the log file even while it is being updated A shareware version of LIST is available Time Stamp PC console messages include a time stamp that contains hours minutes and seconds The time stamp helps you track file activity and is included in the log file If messages are longer than 80 columns they wrap to the next line START SPOOL1 STOCKUPD RPT to LPT1 15 35 09 END SPOOL1 STOCKUPD RPT to LPT1 15 38 23 Message Colors Console messages are color coded Green Messages in green pertain to information sent to the mainframe for example files and commands Green also is used on the Status Line to display the number of lines sent and on the Communication Scope to indicate when data frames are sent White Messages in white
126. most common method n o 2 E a 3 G a a Fq oa Verify Check that each card contains 80 bytes If Input mode is ASCII the software verifies that after every 80 data columns there is a carriage return and line feed CR LF and includes them in the data file If Input mode is Binary the software verifies that after every 80 data columns there is a carriage return CR and then discards the carriage return If a character is lost during data input the job is canceled and the next job will start after the end of file card FF After the end of file marker has been detected all characters are thrown away up to and including the next form feed Close input file on timeout This option can release the COM port if the source device becomes disabled while sending a file or if the end of file marker is accidentally omitted from the file When the COM port is not released the port remains busy and other data cannot be sent or received on the port No Default The file is not closed until an end of file marker is detected Yes If an end of file marker is not detected the file is closed after the timeout period specified by the Timeout in seconds option 70 8 4 COM1 COM4 Devices Timeout in seconds If data input on the serial port stops the software will close the input file after the specified period of time This time period during which no data is received is called a timeout and is mea
127. of the output for the SYSUDUMP ddname for all jobs N ALL in the output service queue Specify the job name or job number in the J nnnn parameter I U J nnnn REQ ALL DD ddn N ALL displays the processing requirements REQ ALL and a summary of the output for the specified ddname DD ddn for all jobs N ALL in the output service queue Specify the job name or job number in the J nnnn parameter R Restart The R command restarts jobs devices or lines gt J 3 2 o o 3 3 D 2 z Format Enter the R command as follows R XX RESTART x X BARR RJE 483 Examples R PRI J restarts the current job on printer 1 R PR2 H Y B Y adds headers and breakers R PR2 H N B N removes headers and breakers R PR2 J restarts the current job on printer 2 S Start The command starts a DSP device ABEND or job Format Enter the command as follows S XX START x X Examples PR1 WC 2 starts output class 2 on printer 1 PR2 WC A starts output class A on printer 2 CA D c lt x PR2 R nnnP starts printer 2 and backspaces the printer nnn pages P PR2 R nnnP starts printer 2 and forward spaces the printer nnn pages P X Call The X command invokes a DSP for execution 484 A 2 JES3 Remote Commands Format Enter the X command as follows X xX CALL x x Examples X WIR OUT PR1 WC class calls the h
128. on the Printer Control Data screen You must use a program editor to enter the printer control codes in the overlay file in hexadecimal format You can send one overlay file before and another one after the print job For example the starting overlay file can set up the printer and the ending overlay file can reset the printer as described in section 18 2 n o 2 E a 3 G a a Fq oa To print certain types of files some printers require additional resources to be loaded You can put files containing printer resources in the overlay directory for automatic loading by the Barr software For example the SNPFORM and SNPIMAGE utilities for Oc printers are used to generate additional fonts or other resources These files are placed in the forms overlay directory Overlay Files for PostScript Printing Barr software can convert data from EBCDIC to PostScript format To enable this feature you need the Barr overlay files 2UP LAND and PORTRAIT included with the Barr reference files You can edit these files and copy them to the forms overlay directory You also must set the receive mode for the host printer or punch device to PostScript on the Assign Devices screen For more information about PostScript receive mode see section 10 8 Creating an Overlay from Several Files You can include several overlay files in a single file by using the Barr embedded send files command The master file contains
129. once per page and if stop 1 is used only on the first print line However if existing FCBs contain multiple occurrences of a given carriage control stop or they use stop 1 after the first print line the FCBs probably will not work for remote printing When the host RJE system processes the FCB image it retains only the first occurrence of each carriage control stop As a result some carriage control stops are not sent to the PC and your data will not print in the expected format To work around this issue you must determine whether it is feasible to redefine existing FCBs or to define new FCBs at the host computer The feasibility of either option depends on your print applications and on whether local printing will continue or be completely replaced by remote printing Discuss these options with the host systems programmer who maintains the FCB library If local printing is discontinued you might be able to change the FCB definitions If both local printing and remote printing will be available you might be able to define a new set of FCBs to use only with remote printing If it is not possible to change or add FCBs you must use the SETUPHDR feature with Barr defined forms Barr forms allow you to define each carriage control stop multiple times per page in the same format used by locally attached printers nm T i 3 Eg i 3 f z i 5 BARR RJE 523 Enabling the FCBLOAD Feature Follow these basic s
130. option you can use PRT to submit files with the S 370 format to the print spool PRT automatically identifies S 370 files and creates the spool header in the S 370 format The Barr PRT utility is included with the Barr reference files You can run PRT interactively from a menu or in batch mode from a DOS prompt PRT gives you remote control over spooling criteria such as form class and priority EFK Install the PRT Program When you install the BARR RJE software files on your PC these PRT program files are copied from the Barr software disk to the C BARR REF directory a PRT EXE a PRTMENU EXE a SPOOL CTR If you want users on the LAN to use PRT copy the PRT program files to a directory on a network drive Note You need both the PRT EXE and PRTMENU EXE files regardless of whether you run the utility in interactive or batch mode N ol a gc mr Es c lt Follow these steps to copy the PRT files to the C BARR directory 1 Create the directory where you want to install PRT and change to that directory For example to install it on network drive F type these commands f md barrprt ed barrprt BARR RJE 433 2 Copy the PRT EXE and PRTMENU EXE files to the new directory copy c barr ref prt exe copy c barr ref prtmenu exe 3 Finally copy the SPOOL CTR file to the new directory copy c barr ref spool ctr EF Create Control Files PRT uses control files to add spool heade
131. pertain to status information received from the mainframe for example responses to mainframe commands N o gt eoj gt J amp m i 3 2 5 Red Error messages from the Barr software display in red a Magenta Messages in magenta pertain to information received from the mainframe for example files Magenta also is used on the Status Line to display the number of lines received and on the communication scope to indicate data frames received Scroll Rate The screen scrolls at four lines per second To pause the screen display press Scroll Lock For fast screen scrolling press Scroll Lock and 1 To slow the scrolling speed press Scroll Lock and 0 Activity Messages Most console messages indicate device activity BARR RJE 353 Startup Date and Date Change When the software starts and at midnight when the PC date changes a console message displays to indicate the date BARR RJE C Barr Systems Inc 1997 Version 97A3 01 31 1997 This message helps you quickly scan the log file to find the start of activity for a certain date Log File Activity Each time a message writes to the log file you might see this console message WRITING CONSOLE LOG To prevent this message from displaying select No Log when you assign LOG FILE on the Assign Devices screen Send and Receive Activity Messages on the console indicate when files are directed from a SEN
132. printer control data with 229 screen 217 218 221 SETUPHDR with 514 515 518 522 EGA 308 monitor 200 Electronic forms 73 99 management 21 Embedded send files command 345 See also send files command EMS 38 End of file marker card reader 70 DOS 68 69 serial port 69 70 VAX 69 English character sets 277 Enter character prompt 34 Enter hex number prompt 34 Enter number prompt 34 EPSON printers 93 105 Equipment errors scope character 367 SDLC statistics 378 X 25 statistics 385 Equipment requirements 10 ERROR file name 172 188 Error file status 409 Error message PRT utility 441 Error messages 29 console 330 331 357 359 ERRORLEVEL 456 Errors 359 802 2 369 370 Coax 372 communications 25 321 See also Equipment errors file name 172 LAN connections 111 Novell print queue translation table 88 See also Printer error SDLC 367 serial port 63 556 Index serial port input 67 X 25 367 Escape sequences See Printer control data Exchange identification Xid 366 368 370 EXE files sending 453 Exit BARR RJE 337 program after disconnect 302 Exit and Save Changes 315 319 Exit Options screen 317 Exit to DOS 317 337 Expanded memory EMS 38 Extended ASCII 58 94 codes 492 Extended memory buffers XMS 304 messages 358 See also XMS Extended memory support 1 External modem 328 F F bit 386 FB record format 181 FCB 95 519 defining at host 523 See also FCBLOAD local handling of 522 523 remote handl
133. printers to individual sheets for laser printers Suppose you need to print one inch labels on a laser printer Each label sheet is a standard 8 5 by 11 inch page with 11 labels per column At the mainframe the page size was one inch one label For the laser printer you need to define the form length to match the actual page size one sheet You also need to define a Carriage Control Table with 1 stops at one inch intervals for the start of every label When it encounters a form feed the Barr software moves to the top of the next label The software tracks where it is on the page and when it reaches the end of the sheet it advances to the next page BARR RJE 227 Edit Forms select one Escape CHECKS PERF STD STD2 Selection l gt 1 Select a blank entry from the forms list Edit Forms Name LABELS Lines per form 66 Print lines per form 66 Lines per inch 6 Printer control 00 Enter character 2 Enter the form name The form name you assign must match the form name specified in the host JCL for the job that generates the print output In this example the form name is LABELS a E ras o L F a Gr pas 3 Leave lines per form and print lines per form at the default of 66 the number of lines per sheet and lines per inch at the default of 6 4 Press to display the Carriage Control Table screen Carriage Control Table The lines
134. sas asses sae eae eee 1 1 1 Equipment Checklist 0 000 eee eee eee 1 PE REQUITEMENIS oeeie Sa rake alot E EAA ecaala garam 1 LAN Adapteri sarei t octet Goi Bat mae eter aes 2 MOE A cea nna teenie aha gig he Baba E a 3 1 2 Package Cont nts s g acir sei iow itee Uw a A EE A RANO 3 EREE e E uae Peay ts Sylora tated A doe EA 4 1 4 Trademarks ena te eth dA ee eg 6 1 5 Acknowledgments 0 0 0c cee enere 7 Chapter 2 RJE Concepts 0 0 c cece eee eee eee eee 9 2 41 Remote JOB Entry acu sania bine veer ewe oes Gia E 9 2 2 RIE Workstations y caves a Oh gaa aia S EA 10 RIELDEVICES cents do thal and AIM Ge Meta Made ekg ted SAI alte Ak Nhe 10 PO Printers iu a hnasd olies Bs eae ee Reed On ola whee 12 2 3 Communication Links and Modems 2 0005 13 Communication Links EAA cee eee eee eee eee ee 13 Modems 29 22 5228 GF ee eee Ue a ee Bee we gatas 14 Chapter 3 Host Environment 0 0 eee eee eee eee 15 3 1 Mainframe to Workstation Communication 15 3 2 RJE and 3270 Workstations and Applications 17 RJE is deiina a aa aa tot Manthckaleets E E A wee 17 3270 Workstations and Applications 006 18 3 3 Communications Networks 0 0 0 seanse eeen 18 MTAM S aa EAA E KA a R e EE 18 NOP eitn A A A EAA E des EE A A 19 3 4 SNA Physical and Logical Units 00 19 BARR RJE v MS rea teed sod a
135. save name d Enter the file name for the control file or accept the displayed name by pressing Enter If you want these settings to be the default settings you must name the control file SPOOL CTR and put it in the same directory as the PRT program files PRT EXE and PRTMENU EXE When you start PRT the utility searches for SPOOL CTR in the current directory and then it searches the directory containing the PRT program file This allows each user to store control files with custom settings on their PC gt D e c a o a 7 wo N 440 25 2 Create Control Files Maintain Control Files with an ASCII Editor You also can create and maintain spool control files with an ASCII program editor if you are proficient with the editor See Table 25 1 for a list of control options and their maximum field lengths A sample control file created with an ASCII editor is shown below class A control 0 copies 3 formname LANSTD locdisp NOCHANGE spldisp DELETE lpf 66 lpi 8 plpf 60 priority 9 spooldir N SPOOL state HOLD Follow these guidelines when you edit control files Specify only those values that will differ from the default values in the SPOOL CTR file The format of each option is as follows keyword value a Separate the values from the keywords with one or more spaces or tabs Enter only one keyword and its value on each line When PRT reads ea
136. save your changes during the configuration process 50 7 2 Installation Description Menu Chapter 8 Devices and Printers From the Devices and Printers menu you select the types of printers and other PC or LAN devices to use with BARR RJE The devices you enable on this menu display on the Assign Devices screen This chapter introduces you to the concepts of source and destination devices and describes the devices you can enable from the Devices and Printers menu oO i o S o o an 9 Ss Z vu Ss a a 8 1 Sources Destinations and Device Assignment To define devices in the Barr software you must understand the concepts of source devices destination devices and device assignment Devices that input data to the software are called data sources RJE printers and punches are data sources because data travels from the RJE print or punch stream into the PC and is processed by the software Devices that handle data output by the software are known as data destinations PC printers and disk files are destinations because data on the PC is sent out to the printer or to a file on the hard disk Figure 8 1 illustrates the PC data flow Routing data from a source to a destination is called assigning devices For instance files received from the RJE print stream can be directed or assigned to write to a printer attached to the PC parallel port paia Sources j Data
137. screen select LOG as the source Assign Devices DESTINATION FILE SCREEN NUL SUSPEND LPT1 COMMAND RD1 SPOOL Selection tJ gt 2 Select FILE as the destination Assign Devices Beginning of file name C CONSOLE LOG Ending of file name is not used Append No Log Enter character 3 Enter C CONSOLE LOG as the Beginning of file name 4 Select not used for Ending of file name 5 Select the Append option to append each message to the log file If you do not select Append a new file will be created each time you start the software 6 Select No Log to prevent the message WRITING CONSOLE LOG from displaying on the screen each time a message is written to the log file BARR RJE 173 4 2 gt 7 i K Assigning Spool as a Destination If you set up the print spool feature you need to direct print files to the spool directory and route files from the spool directory to spool printers from the Assign Devices screen This section tells you how to perform the two assignment steps On the Assign Devices screen the destination device SPOOL represents the spool directory and the source devices SPOOL1 to SPOOL8 are the spool printers or routers Direct Files to the Spool Directory First assign source devices to write to the destination SPOOL The procedure for assigning SPOOL as a destination is similar to assigning FILE as a destinatio
138. send commands referencing the other files This feature allows you to store 100 8 7 Forms Overlay common overlay features in separate files so they can be shared Otherwise you might have to store duplicate copies of the same overlay text and commands in several different overlay files Note When you use ending overlay files you cannot use the embedded send command in either the beginning or ending overlay file of a beginning ending overlay file pair Follow these steps to create an overlay file composed of other files 1 Use an ASCII editor or a program editor to create individual overlay files containing the features you want For example create one file that contains a font code and another file that contains a company logo co i oO S o D a 9 Ss s m 3 a a 2 Use the editor to create a master overlay file that references the files containing the features you want The form of the send command is filel file2 filen Follow these rules when you type the file name list m The embedded Send Files command must be at the beginning of the list a Separate the file names with a space tab or blank line a If the files are not located in the overlay directory specify the full directory path as part of each file name a The overlay file containing the list can have a maximum size of 512 bytes For example you can create an overlay file that includes a tax form a company logo an
139. serial port 497 AT modem 203 204 commands 211 dial up connection 326 options 208 Austrian German character sets 277 Autoanswer on ring option AT modem 209 AUTOCMD BAT 311 Autodial 23 Autodial retries option AT modem 210 Dataphone 2224B 207 AUTOEXEC BAT file share command in 39 startup command in 322 Automatic Call Distributing Unit ACDU 451 B Backslash character beginning of file name 163 168 171 command to host 452 serial port input 66 68 Backspace command JES2 462 Backspacing spool files 423 See also Reprint repositioning Backup configuration 310 317 disk 44 Band printer 12 Banner page 58 file name from 170 188 Novell 114 Novell NetWare 117 Novell print queue 80 separate file for 193 stack face up 58 72 TCP IP LPD 510 TCP IP LPR UNIX 85 BARR GATEWAY pooling 300 session 312 BARR PC SYNC modem 203 264 Barr software files See Software files Barr Systems fax ii mailing address ii Technical Support 400 telephone iii BARR CFG file 316 BARR 2 adapter 264 BARR 3 adapter 264 BARR DPI 12 32 adapter 59 94 cable 94 See also DPI BARR PRINT for LAT 32 195 devices 52 diagnostics 374 disabling spool header 191 BARR PRINT for TCP IP 32 83 devices 52 disabling spool header 191 BARR TAPE 30 176 memory 304 receive mode 176 178 183 screen size 201 session 312 BARR TRAN 31 179 181 343 reader length 293 BARRSNAR EXE file 319 552 Index Batch file AUTOCMD BAT 311 packaging
140. tell the host identification that it wants to make a connection host sends Xid to request identification of remote Xidr Exchange Remote sends identification data IDBLK identification and IDNUM This data defines a switched response PU in a VTAM library Xidrz Exchange Controller responds with routing identification information response Xidz Exchange Remote sends Xidz to host Controller identification Address to request routing information 370 22 3 802 2 Connection 802 2 Examples StatIASKidzMekreXi dreelxidr clo Normal connection if the adapter was not previously opened IA indicates initialization and open StatSxidzMebrrixidhelxidrclo Normal connection if the adapter was opened by other software for example network software StatSXxidz yy The host Controller Address entered in the Communication Link cannot be located on the ring stats Resources are not available to open a SAP When the adapter was first opened by LAN software not enough memory was reserved StatIASXidzXidzXidz No response from the host Check LOCADD under Communication Link for the address of the host adapter otherwise check for a route problem StatIASkidzXidrzxid If you are connecting to a 3174 check Q940 in the controller setup to ensure the Barr device is defined adoag wwo ZZ Ex Coax Connection After the PC connects to the mainframe the remote goes into Normal Response Mode Snrm on the Communication Scope a
141. the Communication Scope the software might send only seven frames at a time as if it was in modulo 8 mode if the PC does not 368 22 2 SDLC Connection have enough memory A or an Rnr on the Communication Scope indicates low memory You also might see the More memory needed for buffers message on the BARR RJE console Try increasing the Memory allocated for buffers option by MAXOUT 1024 As MAXOUT increases so do the requirements for buffers See Chapter 2 of the Host Definition Guide for more information Ex 802 2 Connection After the PC connects to the mainframe the remote goes into Normal Response Mode Snrm on the Communication Scope and data communi cations begin Characters on the Communication Scope reflect activity between the PC and mainframe 802 2 Scope Characters Table 22 4 lists Communication Scope characters for 802 2 connections Table 22 4 802 2 Scope Characters NX Characters Description Notes S 0 7 Information Frame number of the information frame frame S g i A Open Open the token ring adapter Only performed if not already opened c Connection 802 2 connection established established Enn Error status The codes nn are defined in Adapter returned from Check Reason Codes in the Local Area PC token ring Network Technical Reference IBM adapter SC30 3383 2 E09 Adapter not initialized E0C Adapter not opened E22 No response from host E28 Token ring adap
142. the line breaks by inserting a hexadecimal 0D carriage return See Example 4 later in this section and Serial Port Source Options Sample Applications in section 8 4 Printer Control Data Examples These examples show how you can use printer control data Each example shows codes for a different type of printer See section 13 3 Using Printer Control Data with Forms for additional examples of using printer control data with printer forms Example 1 Xerox 2700 Printer This example describes control characters used for the Xerox 2700 You might want the printer to ignore a form feed FF character that occurs as the first byte of the print file This prevents blank pages from printing between jobs If you enter 0C the ASCII form feed character as the first byte of printer control data the printer will ignore the form feed To enable the offset stacker feature at the start of every file enter 1B 6F HEX 0C 1B 6F 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 104 8 8 Printer Control Data Example 2 OKIDATA Printer In this example the hexadecimal code 1D causes the OKIDATA 92 and 93 printers to print in a compressed 132 characters per line mode HEX 1D 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Example 3 EPSON IBM Printer Y
143. the software and adapter addresses do not match the choices displayed for the adapter settings will be different from the ones listed in this section If the PC detects a conflict you must change the adapter hardware and software settings Other choices are 290 2A0 and 2B0 DMA request 1 3 1 amp 3 Channel over which the adapter directly accesses memory DMA is a time honored way to achieve high transfer rates between memory and a peripheral device Special hardware implements 16 bit bus 262 17 1 Adjust Software Settings master DMA The default DMA value is 1 Other choices are 3 5 6 and 7 For the RS232 and V 35 adapters choose 1 3 or 1 amp 3 The software uses only one DMA channel either 1 or 3 for half duplex communications It uses both DMA channels 1 amp 3 for full duplex communications DMA Priority During DMA transfers if another adapter prevents the SYNC ISA adapter from acquiring the bus in a timely manner you might see receive overruns and send underruns indicated by a magenta X on the Communication Scope when the software operates at high speeds As a precaution install the SYNC ISA adapter with the lowest DMA request highest priority of all adapters in the PC This prevents other adapters that inadequately share DMA from affecting performance Perform loopback test The loopback test verifies that the hardware is installed correctly and that the hardware and software settings are correct The l
144. the value here is not 0 contact Barr Technical Support and supply a line trace REJ Number of frames rejected because they were out of sequence Page 4 X 25 Packet Level Statistics Press N to advance to page 4 X 25 Packet Level Statistics Data 0 0 Restart 0 0 RR 0 0 Restart C 0 0 Clear 0 0 Call 0 0 Clear Con 0 0 Call Acc 0 0 page 4 next page reset Any key Packet level statistics provide information about the types of packets received One packet is sent in each Info frame Packets sent display in green in the first column Packets received to the PC appear in magenta in the second column 386 23 3 Communications Statistics EY Line Trace A line trace is a trace of all frames transferred over the communications line Follow these steps to create a line trace 1 Assign the file to write to disk 2 Set up a line trace If the problem Barr Technical Support is investigating involves receiving a file for example a file is not printing or is printing incorrectly you need to receive the file during the line trace and write it to PC disk so you can provide it to Barr Technical Support Assign the device where the file will be received to a file destination The software automatically names the trace file DUMP Be sure to use a different file name for the file you are receiving From the Operation screen select Advanced o p From the Advanced menu select Assign Devices c S
145. use Transparent receive BARR RJE 181 mode if you use the SCS Enabler option on the Xerox 3700 printer or the EBCDIC Parallel Meta GHO Enabler IB option on the Xerox 4235 printer PostScript Convert EBCDIC files to the PostScript format required by PostScript printers You must use the three form overlay files PORTRAIT LAND and 2UP that are provided in the directory C BARR REF PSOVL with PostScript receive mode The overlay files set the printer to the desired mode and define PostScript macros In the received files data converted to PostScript format is enclosed in parentheses Carriage control such as CR LF and FF is converted to macro calls that are controlled by the overlay file Carriage control is placed between data lines 4 2 gt 7 i K You can use PostScript receive mode only with source devices that support receive modes such as PRn and PUn and only with destina tion devices that support form overlays including LPTn COMn and NETn The overlay files contain some user selectable options you can change by editing the overlay file After you make changes with a program editor you must copy the overlay files to the forms overlay directory defined under Devices and Printers Miscellaneous Printer Options To activate the overlay the name of the overlay file must be included in the spool header See section 8 7 Forms Overlay for more information Note 1 Files received from sour
146. v Spooling class Class Provides for grouping Z lt s o v v of similar files Copies NS ea AEE S copies to print Spool Delete or retain the Disposition file after printing X FCB name FCB name s gt 7 7 v File name Name of the file v x y File separator Job header information prints Meader with the file Usually indicates Form name preprinted forms to s P P y 4 s mount on the printer Job name Job name v v v v Lines per form Vertical page size Z V V Print lines Number of print per form lines per page 4 4 4 Lines per inch Pp of print v v ines per inch Printer control string Printer control selector v v Priority Print priority v v v v File spooling state State either Ready to print viv v or on Hold UCS UCS print train name v See section E 4 for more source information File attributes you can use as spool criteria Depends on whether form or FCB controls spool Does not appear in spool header Depends on table match criteria 508 E 3 How File Attributes Are Set EZY Field Descriptions The following fields are included in the spool header The field values are from the example in section E 2 FORMNAME CHECKS The form name for the file for example CHECKS and INVOICES usually indicating the type of form paper to use in the printer LPF 066 The number of lines per form indicating the vertical page size PLPF 042 The number of p
147. v c5 45 E E5 56 V 06 RNL 26 17 ETB 46 66 86 66 f A6 77 w C6 46 F E6 57 W 07 7F DEL 27 1B ESC 47 67 87 67 g A7 78 x C7 47 G E7 58 X 08 GE 28 SA 48 68 88 68 h A8 79 y c8 48 H E8 59 Y 09 SPS 29 SFE 49 69 89 69 i A9 7A Zz c9 49 I E9 5A Z OA RPT 2A SM 4A 22 6A 2 8A AA CA EA 0B 0B VT 2B CSP 4B 2E 6B 2C 8B 2 AB CB EB 0c 0C FF 2c MFA 4C 3c lt 6C 25 8C AC cc 2 EC 0D OD CR 2D 05 ENQ 4D 28 6D 5F _ 8D AD 5B cD ED 0E 0E so 2E 06 ACK 4E 2B 6E 3E gt 8E AE CE EE OF OF SI 2F 07 BEL 4F 7c 6F 3F 8F 2 AF CF EF 10 10 DLE 30 50 26 amp 70 2 90 2 BO DO 7D FO 30 0 11 11 Decl 31 51 2 71 2 91 6A j B1 D1 4a J F1 31 1 12 12 DC2 32 16 syn 52 72 92 6B k B2 D2 4B K F2 32 2 13 13 DC3 33 IR 53 73 93 6C 1 B3 D3 4C L F3 33 3 14 RES 34 2 PP 54 2 74 2 94 6D m B4 D4 4D M F4 34 4 15 NL 35 TRN 55 75 95 6E n B5 D5 4E N F5 35 5 16 08 BS 36 NBS 56 76 96 6F o B6 D6 4F O F6 36 6 17 POC 37 04 EOT 57 77 97 70 p B7 D7 50 P F7 37 7 18 18 CAN 38 SBS 58 78 2 98 71 q B8 D8 51 Q F8 38 8 19 19 EM 39 IT 59 79 60 lt 99 72 r B9 D9 52 R F9 39 9 1A UBS 3A RFF 5A 21 7A 3A 9A BA DA FA 1B CUl 3B CU3 5B 24 7B 23 9B BB DB FB 1c 1c FS 3c 14 ped 5c 2A 7c 40 9C 2 BC DC FC 1D 1D GS 3D 15
148. value of fields To print screen press both keys Shift PrtSc Any key The product name BARR RJE version number 97A3 and software options RJE SDLC display on the first three lines of this screen Note If you contact Barr Technical Support please provide this information to the support analyst 3 Press any key to advance to the next screen Installation Description Menu The third installation screen is the Installation Description menu which gives you access to the other installation screens 48 7 2 Installation Description Menu Installation Description RJE Description Communication Link Devices and Printers LPT COM NET SEND LAN Print Spool Description Assign Devices Monitor and Adapter Modem Type and Dialing Instructions Printer Forms Function Keys Commands Sent at Startup Startup Screen Notes Interrupt Request Address and Loopback Test Tuning and Global Options N gt an Pa o D i 5 o nan ix kzi Exit and Save Changes Selection l gt Menu Selections The selections on your screen might differ depending on which software you have The menu items RJE Description and Communication Link are discussed in the Barr Host Definition Guide a The rest of the menu items are discussed in chapters 8 through 19 of this manual The chapters appear in the same order as the menu options Modem Type
149. want to display form name or FCB name on the Print Spool screen consider BARR RJE 521 using SETUPHDR instead of FCBLOAD With SETUPHDR and Edit Forms you must define forms in the Barr software under Printer Forms The FCB name included in the SETUPHDR record is used to trigger the software to automatically load the Barr form If you prefer FCBLOAD but cannot use HASP190 and you want to obtain a form name or job name see Other Ways to Obtain Form Name or Job Name later in this section When to Use FCBLOAD with HASP190 The FCBLOAD feature should be used only if all of the following conditions are met The forms at the host are too numerous to define in the Barr software The Barr Edit Forms facility lets you define a maximum of 200 forms You can create up to 100 forms with the base software If you need to define more forms you can request a version of the software that supports 200 forms a The host FCBs are compatible for remote printing See Remote vs Local FCB Handling below to determine if you can use the host FCBs for remote printing A reliable job name is not required The job name provided with HASP190 might not be reliable If FCBs are not already defined at the host it might be more convenient to define forms in the Barr software and use the SETUPHDR feature rather than using FCBLOAD Remote vs Local FCB Handling FCB carriage control stops are handled differently for remote printing than fo
150. 0 2 EXEC PGM IEBGENER 3 3 SYSIN DD DUMMY 4 SYSPRINT DD SYSOUT A 5 SYSUTL DD 6 SYSUT2 DD SYSOUT A DCB BLKSIZE 80 RECFM FA Besssssssssssssssssssssssssssss End of Page s ss sss ssssssssssss ss View File PgUp Previous Page Scroll Page tJjo Find Text PgDn Next Page Go to Page EBCDIC ASCII Escape The View File menu at the bottom of the screen lists the keys you can use to browse the text in the file These keys are similar to the keys you use for the reprint commands described in section 24 7 414 24 3 Files Command The top line of the screen indicates the current page line and column positions of the file These numbers are updated as you scroll through the file Note If the file contains line overprint instructions the overprinted lines might appear as separate lines on your screen but the file will still print correctly 2 Press once to return to the Files command menu or twice to return to the Print Spool screen View a Spool Header The spool header contains information that BARR RJE converts to printer instructions and sends to the printer before the file Some of the fields from the spool header display as file attributes on the Print Spool screen If you want to see all the attributes use the View Header command You might want to view the spool header in these situations Before you print the file so you can determine printer settings such as li
151. 0 1200 2400 The baud rate in bits per second controls the rate at which data bits are transmitted The receiver and sender must transmit at the same rate Which speeds your PC supports depends on the COM port in your PC Performance Tuning To achieve rates above 9600 bps you might need a PC with a Pentium processor and a COM port with a buffering 16550 UART chip Parity A parity bit can be added to each transmitted character to aid in error detection The parity selection must be the same for both the sender and receiver None Default No parity Odd Sum of 1 bits is odd BARR RJE 63 Even Sum of 1 bits is even Data bits Specify the number of bits transmitted for each character The number of data bits for both the sender and receiver must match an amp 8 Default Eight bits are required for binary data gi 2 7 Typically this value is not used although it works for seven bit 2 ASCII data Stop bits Data travels on a serial line as a 1 or 0 The beginning of a data string is indicated by one start bit The end of a character is indicated by one or two stop bits Choose the number of stop bits required by the receiver 1 Default One stop bit is used at the end of each character 2 Two stop bits are used at the end of each character Hardware flow control Specify whether the serial printer uses hardware flow control Flow control prevents congestion of data caused by one devic
152. 0 00 ee eee eee eee 147 Chapter 10 Assign Devices 200 cece eee eee eee 149 10 1 Data Flow to and from the PC 0 0000 149 Data Flow between the PC and Host 00 149 Data Flow between the PC Devices and the LAN 150 Vill Contents 10 2 Assignment Screen sn ses negan roa ada eee eee eee 151 Device Assignment aeniea 0 ccc cee eee ee eens 152 Menu Selections eseye rue 0 00 a eee eee ee 152 10 3 Source and Destination Devices 0 00000 153 OUNCES draa nt ea oe Sais case eta A OREA aaa Sa E tals jae deh S 154 Desna ons aeeoe GPRS Ne aise ate et A S Sue ar ateteg mages aces 157 10 4 Assigning a Printer as a Destination 160 10 5 Assigning a File as a Destination 00 161 File Screen e niri iA E Arete cea Rage Saad ede Suet AN 161 File Name Extensions i mor aene o ao a a ee eee ae 166 File Name Examples soine aisinn maa naai a a a aaa 167 File Name Error Handling 0 0000 00 00 172 10 6 Logging Console Messages 0 0 0 c eee eee 173 Assienment Steps ve wn eee aan wee ae Reema ga 173 10 7 Assigning Spool as a Destination 04 174 Direct Files to the Spool Directory 0 0 00 174 Direct Spool Files to Printers 0 0 0 0 000 000020 175 10 8 Receive Mode 0 E E eee eee 176 Receive Mode Menu sagen cirie raioh c cece eee e
153. 0 eee e eee 403 Managing Print Spooling 0 0 ce eee eee eee eee 404 Steps for Printing Files cirein ptit eee cece nee 404 How the Print Spool Selects Files for Printing 405 Printer Attributes noaa rig pada A iar t a EEEa 406 FleAttrib tes ieia an ik a A A EAK A E AEE 407 Spooling Commands 0 eee eee eee ee 410 Malu part PUS orere tere AL EEEE son ae RRETA 411 P inters Command con sosi muasa pan aaien a aiaa S 412 Files Command 0 0c cc cece cee eens 413 Ready FISSA a aara acta uty ath abt Sandra EEE heh wate 413 View a Pile jase doh bets Ree ad dG ats eee oes 414 View a Spool Header 2 eee eee 415 Change Attributes for One File 0 0 00 00 416 Change Attributes for a Group of Files 0004 416 Delete a File or a Group of Files 00 417 Sore Command wih 5 oo ed eee A HS we EB BR ce 417 Check Spool Command 0 0 00 cee eee eee 418 Adding PC and LAN Files to the Print Spool 418 Using the Check Spool Command 00 419 Restore Command 0c c cece eee eee eee 420 Restore a Bile Loret ak a ng aed e ole a ada lend q Bolen atA 421 View File Attributes 0 000 00 422 Reprinting Files sses iseun eee eee eee een eee 423 Select a File to Reprint era iaee cece eee nee 424 Reprint Commands 0 eee eee eee eee 425 xiv Contents 24 8 Cha
154. 00 c eee eee teens 457 How to Connect the Host and Remote 457 Remote Commands 00 cee cece e eee ees 459 JES2 Remote Commands 0 000 c ee eee eee 459 JES3 Remote Commands 0 00022 e eee eee 481 VSE POWER Remote Commands 000 485 ASCII and EBCDIC Standards 0005 489 Sending ASCII Data 0 eee eee eee 490 Receiving ASCII Data 0 cee eee 490 BARR RJE B 3 EBCDIC and ASCII Translation 000 491 B 4 ASCII to EBCDIC Translation Table 4 493 B 5 EBCDIC to ASCII Translation Table 0 494 B 6 Legend of Characters 0 0 0 0 eee eee eee eee 495 Appendix C Serial Port Interface 000 eee eee eee eee 497 C 1 Signals for 25 Pin Serial Ports 00 497 C 2 Signals for 9 Pin Serial Ports 0 0 0 00 00 498 C 3 Printer Cable Specifications for 25 Pin Serial Ports 498 C 4 Printer Cable Specifications for 9 Pin Serial Ports 499 Appendix D Printer Test 200 e eee eee eee eee eee 501 D 1 Test the Printer from DOS caresser ses sarat tr aD eee ee eee 501 D 2 Test the Printer from BARR RJE 0 000 e eee eee 502 Appendix E Spool Header 00 e cece ee eee eee eee 505 E 1 Enabling the Spool Header 0 0000 505 E 2 Spool Header Format
155. 00000011111111112222222222333333333344444444445555555555666666666677777777778 12345678901234567890123456789012345678901234567890123456789012345678901234567890 1 Enter character Note that the length of the entry line reflects the value 82 you entered for Print lines per form The entry line wraps to a second line after 80 characters In this example the default Carriage Control Table with a 1 on line 01 is all that is required 5 When you press Enter the form list is updated to reflect the new form definition BARR RJE 225 a E ras o a Gr pas Edit Forms select one Escape CHECKS STD PERF Selection l gt 6 To re display the forms in alphabetical order press Esc select Edit Forms and then press Enter Example 4 Two Page Form This example shows how to create a two page form that lets you control whether data will begin printing on an odd or even page This is also called printing on the inside fold or outside fold of the paper stack The form definition must have two pages so the number of print lines per form will be twice the number of lines per form Edit Forms select one Escape CHECKS PERF STD Selection gt 1 Select a blank entry from the forms list Edit Forms Name TD2 Lines per form 66 Print lines per form 132 Lines per inch 6 Printer control 00 Enter character
156. 1 RD2 RD3 and RD4 you might need to specify a send mode after the file name The send mode tells BARR RJE what format to use when it sends the file To specify a send mode follow the file name with a slash and then the send mode character The send mode options A B T V and 1 to 9 are counterparts to the receive modes on the Assign Devices screen Section 10 8 describes the receive modes i o a i Wu c gt s c co rr N Note The DOS send mode has been replaced with the TB send mode See section 26 2 for information about using the TB format to transfer files between two PCs or two remotes A ASCII which is the default if you do not specify a send mode ASCII mode indicates that the file consists of data lines ending in a carriage return character BARR RJE converts the data lines to EBCDIC as it sends them to the host Packed decimal data Before you transfer data that includes packed decimal fields use a separate program to unpack the data Packed decimal data gets corrupted during translation from ASCH to EBCDIC with any file transfer program 342 21 4 Send Files Annn ASCII with a maximum reader length For nnn substitute a maximum reader length from 1 to 254 This option lets you override the maximum reader length specified on the Tuning and Global Options Reader Control screen BARR RJE converts the data lines to EBCDIC as it sends them to the host B Binary or unknown
157. 1 Move the cursor to the desired file 2 Press V to view the file 3 After you view the file press to return to the Restore screen 422 24 6 Restore Command Restoring files from C SPOOLRET Spooling paused File State Form Class Prty Copies Size Date Time PAYROLL 003 BOND 1 2 1 10023 02 12 97 7 49 PAYROLL 002 7099 02 12 97 8 03 PAYROLL 001 13240 02 12 97 8 29 Select file using t and press Space to mark V to view or H to view header Ins restores files Del deletes files Sort Escape The form class priority and copies attributes for the selected file display on the screen Reprinting Files You can use the reprint feature to do the following Print a portion of a large file Backspace after a paper jam or other error a Print another copy of a file after it was retained To use the reprint feature the file must be in the spool directory If you want to reprint a file from the retain directory you must first restore it to the spool directory with the Restore command described in section 24 6 N A m 53 N g 2 3 e S If you cannot locate a file in the print spool or in the retain directory it was deleted To reprint it you must send it again from the original source to the spool directory If a backup copy of the file exists you can copy it to the spool directory as described in section 24 5 You can set up the software to display and
158. 1 seven or more consecutive 1s not with a frame character c CTS failure Clear To Send signal is not available from modem E Error with CRC computed on bits in frame received does Cyclical not agree with CRC value of frame sent For Redundancy example noise on the telephone line could Check CRC cause a bit to be lost in the frame The SDLC of frame protocol causes the frame to be re sent F Send failure Transmit clock signal is probably not available from modem N Non productive None of the frames received in the last 5 receive seconds match the SDLC address or they were random noise frames Q Queue More frames received than buffers available overflow Try increasing Memory allocated for buffers to 400 000 See Trace and Memory Options in Chapter 18 for more information T Timeout No answer for 3 seconds Numerous timeouts could indicate that the Barr software is set for DATMODE FULL but the host is set for DATMODE HALF See Chapter 2 of the Host Definition Guide for more information about DATMODE V Overrun of Ending frame character was not found before receive buffer buffer was filled X Equipment Send underrun or receive overrun Usually error caused by LAN or hard disk turning off interrupts Try changing the Interrupt request in the software For older adapters such as the BARR 3 try setting Use DMA for communications to Yes Your Barr adapter manual discusses this option If this error is related to typin
159. 190 message to obtain these values for display on the Print Spool screen Figure F 2 on the next page shows how the FCBLOAD and HASP190 information is combined When you enable the HASP190 message the host sends the HASP190 message to the PC before each file BARR RJE processes this message and extracts the desired information i E i 2 E L L 520 F 3 Using FCBLOAD with HASP190 The HASP190 message contains this information Form name FCB name Job name You can use form name FCB name or job name to load a form overlay or to name the PC file If you are spooling print files you can display FORMNAME and FCBNAME on the Print Spool screen FoB PC with LPI LPF CC Stops E Barr software m i HASP190 Job Name Form Name Mainframe A Spool Header Job Name Form Name LPI LPF CC Stops CC Carriage control Figure F 2 BARR RJE combines information from the host FCB and host HASP190 message to provide form information for the file Operating Systems that Support FCBLOAD Operating Systems that Support HASP190 These operating systems support FCBLOAD a MVS JES2 XA a MVS JES2 ESA a MVS JES3 VSE POWER and VM RSCS do not support FCBLOAD to SNA remotes nm n i 3 S i 3 2 z i 3 MVS JES2 ESA and MVS JES2 XA support the HASP190 message If the HASP190 message cannot be enabled at your site and you
160. 1A characters in the data to a tilde because 1A is the end of file marker used by DOS Converting these characters prevents DOS from prematurely ending the file Note 1 If you send the serial input data to the mainframe by assigning it to a host reader for example COM1 RD1 on the Assign Devices screen the reader device converts ASCII data to EBCDIC This is the same conversion performed when you set SEND1 RD1 and use the Send Files command Note 2 Any file that begins with a leading backslash which signals a command to host will be forced to ASCII input mode 68 8 4 COM1 COM4 Devices Binary Data to be input on the serial port is in binary format To determine the end of the input file the software checks for the the end of file character you specify with the End of file marker option Unlike ASCII input mode when the end of the file is reached the DOS end of file character is not added If you use binary input mode XON XOFF flow control is not recommended Note If you send the serial data to the mainframe by assigning it to a host reader for example COM1 RD1 on the Assign Devices screen the usual ASCII to EBCDIC data conversion is not performed This is the equivalent of setting SEND1 RD1 and using the Send Files command with the B option for binary send mode See section 21 4 for more information about the Send Files command and binary send mode co i oO S o D a 2 Ss s m Ss a
161. 20 minutes from the telephone company s Automatic Call Distributing Unit ACDU Uploading information from a Cardamation 600 card per minute reader BARR RJE 45 Connecting a MICOM port selector with up to seven attached PCs to BARR RJE Then inputting jobs from the other PCs via the MICOM and sending the jobs to the host system Conversion Steps Follow these steps to set up protocol conversion 1 From the RJE Description screen specify the number of readers and printers Printers 2 max 7 Punches 1 max 4 Readers 2 max 4 2 From the Serial Port Options screen under Devices and Printers set the baud rate of the serial port to the serial line s required value 3 The file can be preceded by a string of characters called a Serial Port Input Header to form it into a job for the host operating system Enter these characters on the Printer Control Data screen Section 8 8 Printer Control Data includes an example of the Serial Port Input Header 4 From the Assign Devices screen assign COM1 to RD2 COM1 RD2 5 Send the files from a VAX or other device A Ctrl Z hexadecimal 1A indicates the end of each file input from a serial device Note If the first character read from the serial port is a backslash the data line will be sent as a command to the host You can terminate the command with a carriage return or Ctrl Z Test Mode To test input from the serial port use Test mode From the Tuni
162. 200 gateway 27 Memory allocation 23 303 buffer shortage message 357 conventional 303 extended 304 managers 38 requirements 1 suspended device uses 158 Memory Allocated for Buffers modulo 128 369 Memory buffers messages 357 Memory dump 400 DUMP file 398 generating 398 sample 400 Message to remote 464 Messages console 352 receive 363 send 363 MICOM port selector 452 Microfiche devices COM 6831 32 Datagraphix 32 Komstar 32 Optistar 32 XFP2000 32 Micrographics Technology COM 6831 32 Minimum length of reader line 293 number of LUs 296 Miscellaneous Printer Options screen COM device 71 LPT device 56 NET device 91 Mode bw80 command 41 48 Modem 16 453 AL mode 269 AT 203 204 AT autodial 326 autoanswer 24 autodial 23 326 Dataphone 2224B 203 204 dialing 328 329 external 203 204 328 329 full duplex 297 half duplex 297 internal 264 not autodial 204 PC SYNC 203 264 326 requirements 3 setting for PC to PC file transfer 453 speaker 210 testing 265 268 269 Modem and Line Control screen 294 Modem Connection screen 205 Modem Options screen AT modem 209 Dataphone 2224B 207 Modem standard option AT modem 209 Dataphone 2224B 207 Modem Type and Dialing Instructions screen 203 Modify command JES3 482 Modify options modem connection option 206 Modulo 128 28 365 368 Modulo 8 28 368 Mohawk tape support 30 Monitor 199 color 23 308 default 200 display mode 41 monochrome 23 200 screen save 307 speci
163. 377 X 25 384 Receive failure 367 Receive files activity 354 messages 354 Receive mode 176 asterisk 177 197 choices 178 disabling 310 fixed length options 183 screen 176 177 196 Spool printers 176 RECFMS 394 Reconnect to host 338 interval 302 periodically 302 Record delimiter choosing 313 Record format 181 Record length fixed length 184 Redirect LPT output 54 159 Reference files 39 Release command JES2 461 473 VSE POWER 487 Release serial port 70 Remote communication role 296 457 connecting to host 457 console 23 number 247 336 Remote job entry 9 Remote printing FCBs for 523 Repeat Command function 249 Repeat command JES2 472 Replace Conditional option 165 Replace option 165 Reprint commands 425 fast repositioning 131 512 files 423 include form header 131 messages 355 offset code 510 printer state 406 repositioning 425 screen 424 state 148 Reprint offset spool header 510 REQMS 394 Request To Send RTS 497 constant 297 Requirements hardware and software 1 Reset printer See Printer reset string Reset to factory defaults option AT modem 211 Response Time Monitor screen 396 566 Index Restart automatic 24 BARR RJE 337 Restart Actions 301 screen 301 456 Restart command JES2 469 JES3 483 Restore command 420 screen 124 Retain directory See LAN connection retain directory See PRT retain directory See Spool Retain directory Retain options spool 132 Retry file state 90 409
164. 4 R VSE POWER Installation and Operations Guide SH12 5329 VM RSCS Planning and Installation SH24 5057 VM RSCS Operation and Use SH24 5058 OS VSI RES System Programmer s Guide GC28 6878 Microsoft MS DOS User s Guide and Reference Using IBM Disk Operating System Version 4 00 SNA Sessions Between Logical Units GC20 1868 SNA Format and Protocol Reference Manual Architectural Logic SC30 3112 SNA Formats GA27 3136 IBM 3270 Information Display System 3274 Control Unit Description and Programmer s Guide GA23 0061 Component Description for the IBM 3776 and 3777 Communication Terminals GA27 3145 NCP Resource Definition Guide SC30 3447 NCP Resource Definition Reference SC30 3448 Tuning and Problem Analysis for NCP SDLC Devices GG24 1629 VTAM Installation and Resource Definition SC23 0111 VTAM Version 3 Releases I and 1 1 Customization LY30 5614 VTAM Diagnosis Guide SC27 0615 BARR RJE 1 Introduction Communications Applied Data Communications Handbook Universal Data Systems Motorola Inc 5000 Bradford Drive Huntsville AL 35805 1993 Phone 205 430 8000 IBM Dictionary of Computing Options and Adapters IBM Technical Reference Options and Adapters Volume 1 Local Area Network Technical Reference SC30 3383 ERY Trademarks Barr Trademarks The Barr logo is a registered trademark and BARR 3780 BARR HASP BARR RJE RJE 3270 BARR TAPE BARR TRAN
165. 50 ms default 50 ms Speaker Select whether the modem speaker is enabled You can use the speaker to monitor dialing and connection Choose one of these selections On default off 210 12 4 AT Modem Options Reset to factory defaults Select whether to reset the modem to the factory defaults See the following Command Strings section for more information Yes Default Sends the Set Factory Defaults command string to reset the modem to the factory defaults No Does not reset the modem to the factory default settings Command Strings This section documents the AT modem command strings Note The vertical bar character signifies an ASCII carriage return which is hexadecimal 0D ss N 2 D Ej 5 a 2 o 5 a Reset to Command Mode Puts the modem into command mode to accept AT setup command strings In the command sequences below DTR is always lowered before this string is sent because this string is ignored unless DTR is low in some modes Set Factory Defaults AT amp F amp F restores the factory defaults First Initialization ATE0V0S7 60 E0 turns off command string echoing V0 sends result codes from the modem as digits instead of words 7 60 means the modem waits up to 60 seconds for a connection Second Initialization ATS26 15M1S0 0 amp D2 26 15 sets the RTS to CTS delay to 150 milliseconds M1 tums off the speaker until it establishes the connectio
166. 509 Linewriter printers 93 control codes 97 Link diagnostics 375 Link statistics 802 2 381 List command JES2 472 LIST program 353 Load forms 350 LOCADDR Local Address 19 Local disposition PRT 438 Local host name 84 Local printing FCBs for 523 LOCNAME spool header 509 LOG device 153 155 176 186 356 assigning to file 173 352 354 355 Log file See Console log file Log operations NET device 91 spool 130 Log No Log option 166 170 171 173 354 Logical not sign translation of 491 Logical Record Length LRECL 184 Logical unit LU 19 multiple LU protocol 21 28 LOGMODE 330 390 Logon 21 23 automatic 23 error message 330 restart 24 successful 330 to multiple sites 322 Logon error messages 363 Logon Type Host Initiated 296 Loopback test 30 261 263 264 267 Loopback Test of SYNC Adapter screen 267 Lotus files 453 LPD protocol 83 LPF See Lines per form LPI See Lines per inch LPR print queue 82 LPR LPD control file 84 LPT Device screen 54 LPT1 LPT3 13 21 153 158 disable 55 enable 53 55 network redirection of 54 159 options 54 55 BARR RJE 561 LUI allocating 296 LUs 19 bind data 390 See also Logical Unit maximum number of 296 minimum number of 296 Machine carriage control 181 187 188 439 509 Magnetic tape 184 See also TAPE device Manual dial 328 Maximum length of reader line 293 number of LUs 296 print position 291 MAXOUT modulo 128 369 McData 6
167. 54 file attributes 410 DATMODE FULL 27 DAVFU printers 57 72 93 94 See also Vertical Forms Unit VFU DCB 183 Decimal point 496 Dedicated line 14 28 298 scope characters 368 Default monitor 200 Delete file status 409 files after sending 347 received files 165 spool retain files 133 Destination devices 51 153 assigning printer as 160 assigning several sources to 193 194 descriptions 157 maximum number of 153 screen 157 Device assignment 26 status 323 Device control VSE POWER 485 Device driver extended memory 304 NET device 74 75 77 81 Devices assigning 51 149 JES2 cancel command 463 names 460 RJE 10 suspending 158 Devices and Printers screen 51 52 DFT protocol 27 Diagnostics adapter 30 264 communications 29 373 files 387 line trace 306 link 375 modem 30 printer 501 software options 374 Diagnostics screen 373 374 Dial up line 13 28 298 PC to PC file transfer 453 scope characters 327 364 Dialing instructions 203 Directory current 162 163 root 162 Disable console commands 256 device 158 Installation Description 256 Disable waiting message before exiting 313 Disable Printer reprint command 428 Disabled printer state 406 Disconnect from host 337 if idle 301 Disconnect Link 337 Disconnect then exit 337 Disk files 39 send files from 341 space requirements 2 Disk full 110 133 message 359 Disk performance turn off verify 309 Disk space free 110 saving 291 BARR RJE 555
168. 59 4 If you enter no information for your site blank out the fictitious default information 5 Press to store your changes and return to the Installation Description screen o o n 2 5 n 260 16 Startup Screen Notes Interrupt Request Address and Loopback Test You can tell BARR RJE which PC resources your Barr communications adapter uses on the Interrupt Request Address and Loopback Test screen discussed in section 17 1 Because requirements vary by adapter particularly for the T1 SYNC adapter see your adapter manual for information about setting the interrupt request device address and DMA fields The screens in this chapter show defaults with no adapter or a Barr SYNC ISA adapter installed Section 17 2 describes how to use the loopback test software included with your Barr adapter Use this test to verify that you properly installed the adapter and that it functions correctly The loopback test varies slightly from adapter to adapter See your adapter manual for adapter specific information about the loopback test Adjust Software Settings 1 Start at the BARR RJE Installation Description screen _ N 3 o 3 J o 2 an m Installation Description RJE Description Communication Link Devices and Printers LPT COM NET SEND LAN Print Spool Description Assign Devices Monitor and Adapter Modem Type and Dialing I
169. 6 1 5 1 246281 0 busy 2 Form Date Time 8 REPORT QTR RPT 001 LPT1 STD 66 1 5 1 246281 10 02 96 14 47 a REPORT QTR RPT 002 STD 66 1 5 1 236841 10 02 96 14 49 5 REPORT IN STOCK 001 STD 88 1 5 1 500601 10 02 96 15 06 BOND PAYROLL 004 SPC 44 1 3 1 16623 10 03 96 8 50 a INVOICES SALES 004 SPC 66 2 3 3 13240 10 03 96 8 50 i oa Printers Sort Help o Files Check Spool Escape 8 Start printing before end of file is received Specify whether the file starts printing after the entire file is received or whether the file starts printing while it is being received Yes Default Printing starts without waiting for the end of the file to be received This feature is especially useful for very large files that take a long time to receive because the files will start printing much sooner No Printing starts after the end of file is received Use this method if the communications line speed is not fast enough to drive your printer at full speed The print spool can drive the printer at its rated speed If the communications line is slower than the printer this choice prevents the printer from pausing to wait for more data from the communications line Sort spool files by ___ Specify up to four fields for sorting files during print spooling Files print in the same order that they display on the Print Spool screen Spool files are sorted by the first field and then subsorted by the remaining three fields Follow th
170. 6 and Print lines per form is 60 then the printer skips over the last six lines as a page margin A common use of the page margin is to leave three lines on each side of the paper perforation when you use perforated paper Local Disposition Disposition of the original file after copying into the spool directory Choose from three possible values NOCHANGE Leave the file in its original directory after copying to the spool directory gt D e c a o a 7 wo N DELETE Delete the file from its original directory after copying to the spool directory RENAME Copy the file to the PRT retain directory and delete it from its original directory after copying to the spool directory The rule for automatic generation of numeric file extensions in the spool directory also applies to the PRT retain directory 438 25 2 Create Control Files BARR SPOOL Disposition Disposition of the spool file after it prints RENAME Copy the file to the spool retain directory DELETE Delete the file Use file separator headers Choose whether to generate header pages to separate print output Yes Default Generate file separator pages A file separator header page can be used to identify printed files The job name can be included on the header page by entering an appropriate identifier in the Jobname field No File separator headers are not generated ASCII ASA A flag indicating whether to convert ASA carriage cont
171. 7 6888 6989 6A91 6B92 6C93 6D94 6E95 6F96 7097 7198 7299 73A2 7423 7504 76A5 77A6 78A7 79A8 TAA 7BC0 71C4F 7DD0 TEAL 7F3F 806F 816F 826F 836F 846F 856F 866F 876F 886F 896F 8A6F 8B6F 8cC6F 8D6F 8E6F 8F6F 906F 916F 926F 936F 946F 956F 966F 976F 986F 996F 9A6F 9B6F 9C6F 9D6F 9E6F 9F6F A040 A15A A27F A37B A45B A56C A650 A77D A84D A95D AASC AB4E AC6B AD60 AE4B AF61 BOFO B1F1 B2F2 B3F3 B4F4 B5F5 B6F6 B7F7 B8F8 B9F9 BA7A BB5E BC4C BD7E BE6E BF6F Press any of the keys 0123456789ABCDEF Enter Esc CO7C cicl C2C2 C3C3 c4c4 C5C5 C6C6 C7C7 C8C8 cgcg CAD1 CBD2 CCD3 CDD4 CED5 CFD6 DOD7 D1D8 D2D9 D3E2 D4E3 D5E4 D6E5 D7E6 D8E7 D9E8 DAE9 DBAD DCEO DDBD DESF DF6D Enter hex data E079 E181 E282 E383 E484 E585 E686 E787 E888 E989 EA91 EB92 EC93 ED94 EE95 EF96 F097 F198 F299 F3A2 F4A3 F5A4 F6A5 F7A6 F8A7 F9A8 FAA9 FBCO FC4F FDDO FEA1 FF3F 2 Edit the table entries and then press to advance to the EBCDIC to ASCII translation tables Guidelines for Modifying Translation Table Entries Follow these guidelines when you make entries in the translation tables The translation codes are arranged in columns The current hexadecimal oo im kzi i gt 7 representation for a character is shown on the left side of each column The translation for a character is
172. 71203451672 12 34 09 _ aa HASP200 RMT122 STARTED ON LINE113 SESSION TEDTTB31 NODE NER BFSZ 0512 Figure 23 2 A memory dump includes the version number and PC registers Your DUMP file should match the format of the sample but the data will not match Under extreme circumstances your program could abort and automatically create a memory dump Some of the fields in the dump will not match the sample but the format is the same an S a D S a E E o m N A memory dump begins with the version of the software for example 9743 PC registers and copies of Barr screens 4 Send the file to Barr Systems You need to send two files to Barr Technical Support Copy the DUMP file and the received file to disk Be sure to assign them unique file names Then send the files to Barr Systems See the Contacting Barr Systems Electronically booklet for more information about sending disks or files to Barr Systems 400 23 8 Memory Dump EEX Hardware Queries Use this option to list the Barr hardware installed in your PC and the hardware serial numbers You can display information for hardware with ID chips which includes the SYNC T1 SYNC PRINT370 Rev 4 and ASYNC8 adapters and new hardware keys 1 Start at the Diagnostics menu Diagnostics Statistics Hardware Queries Link Diagnostics Escape Memory Dump Selection l gt 2 Select Hardware Queries
173. 850 multilingual At this time you also might want to install support for a non US keyboard Keyboard installation instructions also are described in your DOS manual 276 18 1 ASCII and EBCDIC Translation Tables 4 In the Barr software specify which EBCDIC code page you are using From the Edit ASCII and EBCDIC Translation Tables menu select Choose Language for translation tables The following screen displays Choose Language for Translation Tables English US 437 Portuguese English US 850 Spanish Austrian German Spanish Alternate Austrian German Alternate English UK Danish Norwegian Belgian Danish Norwegian Alternate Brazilian Portuguese Finnish Swedish Japanese English Finnish Swedish Alternate Spanish Speaking French Canadian French Italian International Selection t 7 The choices listed on this screen correspond to EBCDIC code pages documented in the IBM publication GA23 0061 IBM 3270 Informa tion Display System 3274 Control Unit Description and Program mer s Guide Appendix D APL Text Feature oo im kzi i gt a 5 Select the language used by your host application and press Enter For English you have two choices Choose the one that matches the ASCII code page installed on your PC All other languages require ASCII code page 850 6 After you make a selection a message displays indicating the selected language For example
174. 9 Use Novell print banners Choose whether to use Novell print banners Yes Default BARR RJE provides information to Novell so it can build a print banner page Banner pages are useful for identifying printouts They include the file server and print queue names from the Network Printer Options screen and the user name from the NET Options screen You also can use the next two options to specify additional banner information This feature works for jobs received from the host on either the printer PRn or punch PUn streams n o 2 E a 3 G a a Fq oa No Do not generate print banners Banner name is If you enabled Novell print banners with the previous option select which information to include on the lower half of the banner page Choose from username the default fcbname not used formname and jobname If you select not used none of these fields are included on the banner page If you choose fcbname formname or jobname the corresponding name from the spool header or host data stream will print on the banner RJE 3270 If you have RJE 3270 software note that the job name is not included in 3270 data streams and thus cannot be included on the print banner File name is If you enabled Novell print banners select which information to display in the file name field of the banner Choose from jobname the default username fcbname not used and formname If you select not used
175. 90 03 27 97 10 02 START JOB 19 03 26 97 10 36 END JOB 18 03 26 97 10 36 JOB 15 03 26 97 10 37 SPOOL EXE 156413 03 26 97 11 23 SPOOL CTR 120 03 26 97 14 51 SCAP ASC 765 03 28 97 08 31 SCREEN CUT 2492 03 28 97 09 14 FD 328 03 28 97 11 06 MYLIST 15 03 28 97 11 48 OVERRIDE CTR 120 03 26 97 14 51 ALT 174 03 28 97 11 49 Spool File File Directory DOS Controls View File Quit Copy a file into the spool directory If the words Spool File are unreadable in the command menu at the bottom of the screen you need to exit PRT and type the mode bw80 command at the DOS prompt before you proceed The message in the bottom left corner of the screen describes the action that PRT takes if you press while the command is highlighted To select a command use the arrow keys to highlight it or type the first character of the command name 2 Select Controls Spool File File Directory DOS Controls View File Quit Modify save or load spool controls gt Select Controls N ol a gc vu Es Cc lt 3 Select Modify Controls Controls Modify controls Load controls Save controls gt Select Modify controls 4 Change the spool control options The Spool Controls screen displays the default spool control values from SPOOL CTR Change the option values as needed If you leave any of the BARR RJE 435 gt D e c a o a 7 wo N opt
176. ALT 174 03 28 97 11 49 Spool File File Directory DOS Controls View File Quit Change file display directory or template 1 Select File Directory from the command menu File Directory Enter directory C MISC Enter template Enter new directory for file display gt 5 2 Enter the drive and name of the new directory in this case C MISC x 3 To restrict the display to a group of files you can enter a file name E template The default is to display all files a Lo Directory of C MISC By File Size Date Time File Size Date Time PAYROLL 001 14120 03 26 97 10 39 PAYROLL 002 120 03 26 97 14 51 PAYROLL 004 177917 03 27 97 13 21 PAYROLL 005 180205 03 27 97 10 43 PAYROLL 006 157290 03 27 97 10 02 TAX1040 19 03 26 97 10 36 PRICES 18 03 26 97 10 36 INVOICES 15 03 26 97 10 37 CHECKS 001 156413 03 26 97 11 23 CHECKS 002 120 03 26 97 14 51 CHECKS 003 765 03 28 97 08 31 CHECKS 004 2492 03 28 97 09 14 CHECKS 005 328 03 28 97 11 06 MYLIST 15 03 28 97 11 48 FILEDESC LST 120 03 26 97 14 51 JOELIST 174 03 28 97 11 49 Spool File File Directory DOS Controls View File Quit Copy a file into the spool directory 446 25 3 Operate the PRT Utility The name of the new directory displays at the top of the screen and the list of files is updated View a File You can use the View File command to examine a file on screen before you submit it to the print spool
177. Alt or Ctrl By default function keys are predefined with JES2 commands You can redefine the function keys with other commands or commands for other host systems as described in Chapter 14 Note Some JES2 commands require you to specify the remote number In the default function key definitions the remote number is Remote 15 Be sure to change the function key definitions to include your remote number Command to Host Example This example shows you how to use the Command to Host option to cancel output currently printing from JES2 on PR1 The JES2 cancel command is C C PR1 F1 Display all jobs F2 Status of remote F3 Display forms queue F4 Display all output F5 Drain printer 1 F6 Interrupt printer 1 F7 Start printer 1 F8 Restart printer 1 F9 Delete time stamp FO Backspace 2 pages Esc Enter gt PgUp Col 6 gt Type C PR1 and press Enter C PR1 Operation Command to Host Send Files to RD1 Advanced Quit Send Files to SCREEN Mount Forms Selection tJ Your command to the host displays on the console 336 21 2 Command to Host BEJ Quit Use the Quit option to disconnect from the host reconnect to the host restart the software or exit the software Quit Version 97A3 Disconnect then Exit to DOS Restart program Disconnect Link Connect link Exit to DOS abruptly Escape Selection l gt Disconnect then Exit to DOS P
178. B 38 LPF nn ESC F nn 1B 46 nn nn 01 to 99 less than 10 as ASCII digits if requires leading 0 Double question marks in the control codes represent characters with no ASCII equivalent BARR RJE 97 i S o a v 3 2 m 5 D R Z n o 2 a 3 a o gt oa Table 8 1 Printer Control Codes continued Printer Model Setting Control Codes OKIDATA 2410 2350 LPI 6 ESC 4 1B 34 LPI 8 ESC 5 1B 35 LPF nn ESC 2 nn 1B 32 nn nn 7 to 112 as binary byte OKIDATA 2410 LPI 6 ESC 2 ESCA FF IBM compatible 1B 32 1B 41 0C LPI 8 ESC 0 1B 30 LPF nn ESC C nn 1B 43 nn nn 1 to 127 as binary byte Printronix LPI 6 User manually sets switch P300 P600 LPI 8 User manually sets switch LPF nn 1E 10 r 1F r nn 1 repetitions of Hex 1C VFU Support nn 1 to 132 Printronix LPI 6 CR ETXL P I 6 CR LF P300 P600 0D 03 4C 50 49 3B 36 OD OA with IGP LPI 8 CRETXL P I 8 CRLF 0D 03 4C 50 49 3B 38 OD OA LPF nn 1E 10 r 1F VFU Support r nn 1 repetitions of Hex 1C nn 1 to 132 Printronix LPI 6 SOH 2 P6000 a 34 LPI 8 SOH 0 01 30 VFU Support LPF nn 1E 10 r 1F r nn 1 repetitions of 1C Sand LPI 6 ESC 6 Fujitsu M304x 1B 36 Hitachi FP1500 LPI 8 E parallel LPF nn 1D 41 40 r 1E r nn 1 repetitions of 40 40 VFU Support nn 1 to 176 STC D P I LPI 6 Start LPF with EC instead o
179. BARR RJE a ee ee eee eel SNA file transfer remote job entry and remote printing from a PC Documentation Edition 2 Software Version 97A3 Contents Introduction RJE Concepts Host Environment BARR RJE Features Screen Conventions Software Installation Installation Description Devices and Printers Print Spool Description Assign Devices Monitor and Adapter Modem Instructions Printer Forms Function Keys Startup Commands Startup Screen Notes Interrupt Request Tuning Options Exit and Save Changes BARR RJE Startup BARR RJE Operation Communication Scope Communications Diagnostics Print Spool Operation Spool PRT Utility Special Applications Remote Commands ASCII and EBCDIC Tables Serial Port Interface Printer Test Spool Header Form Information Sources Warranty Information Glossary Index _ N Programmers Tony Barr Zain Basrawala Ken Clark John Estelle Al Hodges Jim Fliess Jon Goldberg Frank Ludwig Dennis Mahoney Editors Craig R Lee Diane Pedersen Kathy Sutton Copyright 1983 1997 by Barr Systems Inc All Rights Reserved Barr Systems Inc 4500 NW 27 Avenue Gainesville FL 32606 7031 Phone 800 BARR SYS 800 227 7797 352 491 3100 Fax 352 491 3141 Internet Support BarrSys com Web site www BarrSys com FTP site ftp BarrSys com About the Cover Fern Hammock Springs also known as the aquarium is located in the Juniper Springs Recreation area of Florida s Oc
180. CDIC ASCII View file contents in either EBCDIC or ASCII This option enables you to view files in the S 370 channel format Press B to view contents in EBCDIC S 370 files Press A to view contents in ASCII Printing Options Start Print Reprint the file Block Print Print a block of text within a specified page range Specify the first page and last page to reprint If you do not specify a Last Page the Last Page defaults to the same value as the First Page which causes only one page to print Enter Block Print range First Page 1 Last Page 1 Escape Enter number If the file contains no form feed characters you are prompted to specify the first line and last line to print within the file If you do not specify a Last Line the Last Line defaults to the value in First Line which causes only one line to print BARR RJE 427 N A mi 3 i 3 i 3 o S 5 Enter Block Print range First Line T Last Line 1 Escape Enter number Note If the file s copies count is greater than one the software will print the specified number of copies of the selected block when you use the Block Print feature If you only want to print one copy of a block set the file s copies count to 1 before you select the Reprint state Eject Page Advance the printer to a new page Disable Printer Change the printer state to Disabled and the file state to H
181. Cancel a Send Files Command 0 000000 344 xii Contents Send Files with an Embedded Command 344 Send Files at Software Startup 0 00 0008 346 Send Files by Using Function Keys 0 2002 e eee 347 Send Files from a LAN Directory 00 0000 eee eee 347 Automatically Delete Files after Sending Them 347 QT SNGV AN COON i 0 5 cha Pe A T E ee eee ay E 348 ASSISNDEVICES woe ETE Hales bea sages eine ea OAS 348 SESSIONS 2 akcend dock a och aaa a daaa aaa ee dnc aan Seth ons dude s 348 DIASNOSUCS che aea a exes ni tems oe cates Gane cinerea ote 350 21 6 Mount Forms 0 0 0 cc ccc cece eee ee ee eens 350 21 7 Console Messages 0 ccc cece d eee 352 Console Feature Snia sanra eleven cated els seas Beate ehivic orale i 352 Activity Messages 0 ccc eee eee 353 Warming Messages i siicssc ketenes Sache Tare nahin widen e wince E S eld 357 Prrot Messines Aa tenet Roce ated E a AAA ened amp 359 Chapter 22 Communication Scope 0 00 cece eee eee 363 22 1 Dial Up Scope Characters 00 0 0000 c eee eee eee 364 22 2 SDLC Connection 0 0 0 ccc eee ees 364 SDLC Scope Characters 0 0 0 0 cece eee eee ee eee 364 SDLC Examples r na E RAs a E EEA te 368 Dedicated Line Examples 00 00 e ee eee eee 368 ModuloI28ritec tah cles Misa eerie Make Sh GAs cess aa tid tod TA ahh 368 22 3 802
182. D device to a destination SENDING C JOB1 to RD1 CLOSE C JOB1 Messages also indicate when data is received to a destination of FILE i o a i Wu c gt s c co rr N WRITING C DATA 001 CLOSE C DATA 001 When you exit the software the console log ends with a message showing the total lines sent and received Lines received nnnnnnnnnn Lines sent nnnnnnnnnn 15 32 47 The same information displays on the Operation screen s Status Line The console message allows you to keep a record in the console log file of the total send and receive activity The maximum value for the counter is 999 999 999 If this number is reached the counter starts over with 0 LAN Connection Device Activity When BARR RJE starts it displays messages indicating the status of the LAN connection directories For example 354 21 7 Console Messages LAN1 Connection enabled Messages on the console indicate when files are routed from a LAN connection device such as LAN1 SENDING C LANIDIR JOB1 001 to LPT1 CLOSE C LANIDIR JOB1 001 If you are not using the LAN connection retain feature a message indicates that the file has been deleted ERASED C LANIDIR JOB1 001 Messages are not written when you delete files from the LAN connections retain directory If you enabled LAN devices but do not see these type of messages check the network connection to the Barr PC
183. DOS version 3 0 or later Contact Barr Systems Technical Support if you need more specific recommendations Extended Memory Barr products support extended memory which you can use to enhance performance Note Barr products do not use the expanded memory feature of memory managers or expanded memory drivers BARR RJE 1 Introduction Hard Drive To achieve optimum performance when you use the print spool or perform other disk intensive tasks use a hard drive with fast access and fast transfer times The required hard drive size depends on the storage needs at your site To determine how much storage is needed estimate that you need 2 000 to 5 000 bytes of storage per page of data or that you can store 200 to 500 pages of data per megabyte of hard drive capacity DOS can only address hard drive partitions of 2 gigabytes GB or less If your hard drive is larger than 2 GB you need to divide it into partitions See your DOS manual for instructions DOS Operating System The PC and the host computer each have operating system programs that direct the flow of data and make the PC easier to use BARR RJE requires the DOS operating system and is compatible with DOS 3 0 or later versions LAN Adapter If you use an 802 2 LLC host connection these items are required Local area network LAN adapter that transports 802 2 token ring frames over a token ring or ethernet network See your LAN adapter manual to determine if your
184. Devices and Printers Menu LPT1 COM LPT3 Parallel printers are attached to the PC parallel ports LPT1 LPT2 and LPT3 are the DOS names for these ports LPT1 is enabled by default See section 8 3 for instructions to set up these devices Performance Tuning For BARR RJE it is more efficient to print to parallel ports than to serial ports coM4 Serial printers and other serial devices are attached to the PC serial ports COM1 COM2 COM3 and COM4 are the DOS names for these ports BARR RJE supports both input and output on the serial ports COM3 and COM4 are supported only on standard PC ISA bus machines They require COM3 and COM4 adapters that can be set to interrupt levels other than IRQ4 and IRQ3 so that the four serial ports use four different interrupt levels Usually COM1 and COM3 use IRQ4 and COM2 and COM4 use IRQ3 However the ISA bus does not allow interrupt sharing which means you cannot use all four ports simultaneously with interrupts when IRQ4 and IRQ3 are the only choices co i oO S o D a 9 Ss es me Ss a a See section 8 4 for instructions to set up these devices Performance Tuning If you do not use the serial devices disable them This frees buffers and makes them available to other program features SEND1 SEND2 LAN1 The SEND devices specify destinations for the Barr Send Files command Usually SEND devices are used to direct files to the mainframe You ca
185. E a 3 G a a Fq oa Lines Default Display the number of lines printed This choice is typically used for line printers Pages Display the number of pages printed This choice is typically used for laser printers Forms overlay directory Use the forms overlay feature to load electronic forms or to send additional printer control data or printer resources to the printer In this field enter the name of the directory where the overlay files are stored Include the drive letter and full directory path Remember to create the actual directory with the DOS make directory md command If you do not intend to use this feature leave the directory name blank For more information about this feature see section 8 7 60 8 3 LPT1 LPT3 Devices KJ COM1 COM4 Devices When you attach devices to the PC serial ports you need to set the options described in this section Serial devices can be used as PC input or output devices After you configure your serial printers you can print a test file to verify that the configuration is correct See Appendix D Printer Test for instructions to perform this test COM Device Menu gt From the Devices and Printers menu select a COM device For example select COM1 co i oO S o a 9 Ss me Ss o a A list of options displays Devices and Printers COM1 deleted Use this device Delete this device Choose
186. E S wi pu B o m m IBM 3270 workstations allow you to view mainframe data and enter transactions These 3270 terminals are central to order entry airline reservations programmer workstations and other applications IBM 3270 printers print reports receipts or other transactions You can use them with 3270 workstations For example you can make a reservation with the terminal while the printer produces a bill or receipt While you perform most data entry and control the mainframe on 3270 terminals you can handle printing and file transfer most efficiently through an RJE workstation Applications The 3270 application programs on the mainframe interact with your workstation through the communications network The application programs write screens to the 3270 workstations and request responses These applications allow you to perform queries database updates order entry and statistical analysis At logon the 3270 user enters the APPLID Application ID of the application program Mainframe 3270 applications include CICS TSO and IMS EEJ Communications Networks IBM s SNA architecture whose software components are Virtual Telecommunications Access Method VTAM and Network Control Program NCP defines mainframe communications networks VTAM VTAM is the most important product in the SNA environment and is common to all SNA host systems VTAM is an operating system program that resides on the mai
187. E cartridge tape drives When you purchase the BARR TAPE option it comes fully integrated in the BARR RJE software BARR TAPE supports the following applications PC to mainframe transfer a Mainframe to PC transfer Receiving print output to tape PC to PC mirror image tape copy Emulation of tape support provided by DATA100 Harris and Mohawk Data Systems Tape to printer 30 4 6 Optional Features Advanced File Transfer BARR RJE offers other file transfer applications besides transferring 80 character records The BARR TRAN option supports file transfer between the MVS mainframe and PC environments in a variety of data formats and record sizes Your BARR RJE package includes BARR TRAN BARR RJE also supports PC to PC file transfer when two PCs run the Barr software A o gt pes wv a m n oO 2 oO a See Chapter 26 for more information about these applications S 370 Channel Attached Printer Support The PRINT370 option drives S 370 channel attached printers at their maximum speeds from a PC PRINT370 includes an S 370 channel emulator adapter you install in the PC with BARR RJE You can attach up to six S 370 channel attached printers to the adapter with a Bus and Tag cable PRINT370 also supports IBM s Advanced Function Printing AFP and the Xerox Printer Access Facility XPAF The PRINT370 option supports these S 370 printers m Xerox 4050 4075 4090 4135 4635 4650
188. File Activity Each time a received file is written to disk messages display on the console indicating the start and end of the file WRITING DAILYRPT 001 CLOSE DAILYRPT 001 These messages are included in the console log file if you enabled the log file by directing LOG FILE on the Assign Devices screen N o gt eej gt J a m i 3 2 5 Spool Activity If you enable the Log operations on LOG device option spool activity messages write to the log file When files are printed from the print spool messages indicate the spool device and destination device to which the file was routed START SPOOL1 STOCKUPD RPT to LPT1 END SPOOL1 STOCKUPD RPT to LPT1 If you print a file with the Reprint option messages display in this format START SPOOL1 PAYROLL RPT to LPT1 REPRINT SPOOL1 PAYROLL RPT to LPT1 END SPOOL1 PAYROLL RPT to LPT1 BARR RJE 355 When files are retained after they print or are deleted messages display in this format RETAINED INVENTORY JOB When you restore files from the retain directory to the spool directory messages display in this format RESTORED LABELS JOB When files are deleted from the spool directory and not retained their disposition is delete messages display in this format DELETED DAILY RPT When files are deleted from the retain directory no messages are logged Printer Activity When you print files that have a Barr spool hea
189. For example BARR RJE serves as a gateway between a LAN and a main frame In contrast a bridge connects systems or networks with similar archi tectures graphic symbols Symbols represented by a picture in contrast to symbols with an alphabetic name such as carriage return half duplex A communications link that allows for transmission of data in only one direction at a time in contrast to full duplex hardware The physical or hard components in a computer system such as a processor memory display and printer Contrasts with the soft information components that include programs and data processed by the computer hardware key A small device used for software pro tection that plugs into the computer s parallel port You can attach a printer cable to the other end of the key The key comes with the BARR RJE 802 2 software HASP Houston Automatic Spooling Priority system A popular enhancement to the IBM operating system that was used for many years as a job entry system for local readers and printers as well as RJE terminals header See spool header hexadecimal A base 16 number system that uses the digits 0 to 9 and letters A to F host computer A large computer that controls the com munications network stores databases and has a large computing and memory capacity Other computers can connect to the host to share its resources IBM International Business Machines Corpora tion IBM PC In
190. II and EBCDIC 271 273 274 276 278 assign to devices 276 280 edit 276 279 Transmission error on serial port 67 speed on serial port 64 Transparent data 184 receive mode 182 273 transmission 28 Tuning and Global Options screen 271 U UCS train name form overlay file 288 289 PDIR 516 SETUPHDR 283 spool header 510 570 Index Units select lines or pages 60 73 UNIX 32 UNIX print queue See TCP IP LPR UNIX print queue Upper memory block UMB providers 38 Use Barr FCBLOAD option 281 286 Use DMA for Communications 367 User connection Novell print queue 78 114 User ID LPR LPD 84 User name NET device 90 Novell print queue 89 V V 35 adapter 263 Variable ASCII lines receive mode 179 Variable length record delimiter 313 Variable length records 179 184 ASCII 185 EBCDIC 185 send mode 343 VAX 32 451 end of file marker 69 receive data from 154 194 VB record format 181 Verify 80 byte cards 70 Verify data after writing to disk 309 Version 100 FAT entries 136 200 forms 216 522 BARR RJE iv 48 FCB Form Translation table 88 IBM 3820 AFP 31 PRT 445 TCP IP LPR 77 82 Vertical bar 1 record delimiter 180 313 343 separating commands 239 Vertical Forms Unit VFU 22 See also DAVFU enable download of 58 support 93 94 98 timing delay 58 VGA 308 adapter 199 monitor 200 Video adapter 199 201 color 23 monochrome 23 View file ASCI EBCDIC mode 427 before printing 414 View File co
191. If you select Form name for Control spool with then FCB is used for the display column heading If you select FCB name for Control spool with then Form is used for the display column heading When a file prints the printer name for example LPT1 displays in the state column For example if you select Form name for Control spool with and set Display FCB name on spool control screen to Yes the Print Spool screen looks like this Printer File State Form LPT1 QTR RPT 001 Printing REPORT FCB STD 66 QTR RPT 001 LPT1 REPORT STD 66 QTR RPT 002 REPORT STD 88 IN STOCK 001 REPORT SPC 44 PAYROLL 004 BOND SPC 66 SALES 004 INVOICES Printers Sort Files Check Spool Class 1 1 1 1 1 2 Prty 5 WW Ulu Copies Size Units Status 1 246281 0 busy Date Time 1 246281 10 02 96 14 47 1 236841 10 02 96 14 49 1 500601 10 02 96 15 06 1 16623 10 03 96 8 50 3 13240 10 03 96 8 50 Help Escape In the first column note the FCB column heading and the list of FCBs In the state column note that the name of the printer displays instead of the word Printing when the job begins to print BARR RJE 127 If you select FCB name for Control spool with and set Display Form name on spool control screen to Yes the contents of the display and control columns will be swapped as shown on the following screen Printer File State FCB Class Prty Copies Size Units Status 5 LPT1 QTR RPT 001 Printing STD 6
192. It is set to the minimum valued needed for your software combination Try using the software before you adjust the default value If you need to increase or decrease the amount of conventional memory allocated for buffers change the value a little at a time on a trial and error basis and test that the software still operates after each change The software has a minimum requirement for conven tional memory buffers and will not operate if this allocation is too low but it is not possible to calculate the minimum value If the value for conventional memory buffers is larger than the amount of memory available on your PC BARR RJE uses all of the available memory when you load it If the value for this option is large there might not be enough memory to use the BARR RJE DOS session Performance Tuning If BARR RJE frequently disconnects from the host computer when you receive large files try increasing the allocation of memory buffers a i A i o Extended memory allocated for buffers This option allows you to use memory beyond the 1 megabyte range normally defined for DOS To use extended memory support with BARR RJE you must load a device driver that supports the Micro soft Lotus Intel and AST Research Extended Memory Specification XMS version 2 0 1988 HIMEM and QEMM386 are two memory managers that support this specification Using extended memory is especially helpful if your BARR RJE co
193. JE 305 a i A i o Line Line Test trace buffer size When you enable the line trace feature the most recent data link control frames are stored in the line trace buffer The line trace is a useful diagnostic tool for resolving communications problems If you call for technical support a Barr Technical Support analyst might ask you to provide a line trace You can enable the line trace on the Diagnostics menu during BARR RJE operation See Chapter 23 Communications Diagnostics for more information The average size for the line trace buffer is 16 000 bytes The maximum value is 64 000 bytes The default value depends on the software options you purchased When you increase the line trace buffer size you reduce buffer space for other software features Increase this value immediately before you take a line trace and decrease it or set it to zero before you return to normal software operation You might want to set the line trace buffer size to zero if you have trouble loading the software or running it in the available conventional memory trace format Specify the default format for the line trace The selection you make displays as the default on the Line Trace screen but you can change the value during software operation The number of bytes captured depends on the value you specified for Line trace buffer size short Default Use the short line trace format For each frame of data
194. JE 141 Follow these guidelines when you make table entries a Use the or keys to move within a table entry and to move from one entry line to another To move from the first entry line to the last one use the key To move from the last entry line to the first one use the key When you finish making entries press to return to the Print Spool Description screen Sample Internal Attribute Table To learn more about how the FAT works review these sample entries for an internal FAT i o N o a i A a oa File Attribute Table Set file attributes for print spool Filename Form State Class Prty Copies Disposition TAX1040 1040 Hold I 5 5 INV99 Z 3 2 LABELS I 2 Delete PAYROLL 9 DEFAULT DEFAULT Hold A 5 Enter character According to this table a All files whose names begin with TAX1040 and have the 1040 form are placed on hold and are assigned Class I Priority 5 and Copies 5 Files are retained after they print unless the spool header contains Disposition Delete Any file with the form INV99 is ready for printing and is assigned Class Z Priority 3 and Copies 2 The file is retained after it prints unless its spool header contains Disposition Delete a Any file with a form name of LABELS is ready for printing and is assigned Class I and Priority 2 The copy count from the file is used If the file copy count is blank a
195. JE 409 Copies Number of copies to print When the spool prints multiple copies the copies value decrements by one as each copy is printed For example if the original copy value is 5 the copies value changes to 4 after the first copy prints If the copies value is greater than one and the printer state is set to Draining before all the copies are printed the current copy is com pleted the copy number is updated and then the printer state is set to Disabled If you use the print spool to direct files to other locations on disk you might want to route only one copy of those files If the received files have a copies value greater than one you can set up the soft ware to send only one copy with the Assign Devices Strip spool header option This feature does not work for files directed to printers Size Number of bytes in the file As the file prints the size field decreases indicating the number of bytes remaining The display can show a maximum file size of over 2 14 billion bytes Date Date the PC file was created Time Date and time the PC file was created o i i 72 pan A Q N Spooling Commands To change file and printer attributes use the spooling commands at the bottom of the Print Spool screen 410 24 1 Managing Print Spooling Printer File State Form Class Prty Copies Size Units Status gt LPT1 Ready STD 1 415 busy LPT2 Ready STD 2 0 bu
196. JE devices readers printers and punches are operands in many of the commands Device names consist of two parts device type and device number For example RD1 is reader 1 and PR2 is printer 2 Because many remote terminals have only one reader one punch if any and one printer most examples in this section use RD1 PU1 or PR1 You can specify up to four readers four punches or seven printers depending on the number and type of devices supported at your remote 460 A 1 JES2 Remote Commands JES2 Job Control JES2 commands limit job or device manipulation to the remote operator s jurisdiction A job is under the operator s jurisdiction if the job s output is routed to that remote or if the job was submitted from that remote If a job submitted to JES2 has not been routed by a ROUTE statement or a DEST parameter the job output automatically routes back to the same facility that submitted it Operator command restrictions prevent outside manipulation or loss of a job and ensure the system s integrity A Release The A command releases a job under the operator s jurisdiction from hold The job resumes normal processing Format The operator can specify a job name or number with the A command A jobname where jobname is the name of the job to be released from hold A Jnnnn where nnnn is a single job number to release that job or a range of job numbers to release a series of jobs from hold releas
197. LU 2D 00 03 00 9D_41 6B 80 00 0D 02 01 lt ACTLU 2D 00 00 03 9D_41 EB 80 00 0D 01 01 00 85 00 00 00 OC OE 03 00 01 00 00 00 40 40 40 40 e 40 40 40 40 lt INITSELF 2c 00 00 02 00_01 0B 80 00 01 06 81 00 C2 C1 E3 C3 C8 40 40 40 F3 08 D5 C5 D9 F1 D1 C5 a BATCH 3 NERIJE E2 F2 00 00 0B D9 D4 E3 F1 F2 F2 6B 6B C2 E2 C9 82 RMT122 BSI gt ACTLU 2D 00 04 00 9D_42 6B 80 00 0D 02 01 lt ACTLU 2D 00 00 04 9D_42 EB 80 00 0D 01 01 00 85 00 00 00 OC OE 03 00 01 00 00 00 40 40 40 40 e 40 40 40 40 gt ACTLU 2D 00 05 00 9D_43 6B 80 00 0D 02 01 lt ACTLU 2D 00 00 05 9D_43 EB 80 00 0D 01 01 00 85 00 00 00 OC OE 03 00 01 00 00 00 40 40 40 40 e 40 40 40 40 gt ACTLU 2D 00 06 00 9D 44 6B 80 00 0D 02 01 lt ACTLU 2D 00 00 06 9D 44 EB 80 00 0D 01 01 00 85 00 00 00 OC OE 03 00 01 00 00 00 40 40 40 40 e 40 40 40 40 gt ACTLU 2D 00 07 00 9D_45 6B 80 00 0D 02 01 lt ACTLU 2D 00 00 07 9D_45 EF 90 00 80 04 00 00 OD 2 lt INITSELF 2C 00 00 03 00_01 0B 80 00 01 06 81 00 C2 C1 E3 C3 C8 40 40 40 F3 08 D5 C5 D9 F1 D1 C5 a BATCH 3 NERIJE E2 F2 00 00 OB D9 D4 E3 F1 F2 F2 6B 6B C2 E2 C9 82 RMT122 BSI lt INITSELF 2C 00 00 04 00_01 0B 80 00 01 06 81 00 C2 C1 E3 C3 C8 40 40 40 F3 08 DS C5 D9 F1 D1 C5 a BATCH 3 NERIJE E2 F2 00 00 0B D9 D4 E3 F1 F2 F2 6B 6B C2 E2 C9 82 RMT122 BSI lt INITSELF 2C 00 00 05 00_01 0B 80 00 01 06 81 00 C2 C1 E3 C3 C8 40 40 40 F3 08 DS C5 D9 F1 D1 C5 a BATCH 3 NERIJE E2 F2 00 00 0B D9 D4 E3 F1 F2 F2 6B 6B C2 E2 C9 2 RMT122 BSI
198. NAK 5D 29 7D 27 9D 2 BD 5D DD FD 1E 1E RS 3E 5E 3B 7E 3D 9E BE DE FE 1F 1F US 3F 1A SUB 5F 5E n IF 22 OF 2 BF DF FF EO When you select Translate control codes to Control codes Table One matches the table above Column one contains the EBCDIC hexadecimal codes for the graphic or control symbol in column three Column two contains ASCII codes for the same graphic symbol The double question marks in column two indicate characters not available in ASCII These characters will be translated to an ASCII question mark The following list shows how Table Two differs from Table One The differences occur when you select either Translate control codes to Control codes or Translate control codes to Question marks Legend Graphic EBCDIC to ASCII Keyboard Vertical Line 6A gt 7C Q Logical Or l 4F gt B3 1 7 9 Logical Not a 5F gt AA 1 7 0 Cent sign 4A gt 9B 1 5 5 If your printer supports these symbols using Table Two makes the symbols print on the PC the same way as on the mainframe Most PC printers support printing these characters 494 B 5 EBCDIC to ASCII Translation Table BB Legend of Characters These characters and symbols display in the translation tables B 4 and B 5 Control Characters ACK Acknowledge BEL Bell BS Backspace BYP Bypass CAN Cancel CR Carriage Return CSP Control Sequence Prefix cul Customer Use 1
199. Northern Telecom Minnetonka MN Marshall Grimm EDS GM Proving Ground Milford MI Rich Kurek CNA Insurance Companies Chicago IL Jim Prestwood Triangle Systems Inc Durham NC Joe Ragland Triangle Universities Computation Center Research Triangle Park NC Graham Roberts ACTNET Rivonia South Africa Michael Ronayne Paramount Publishing Old Tappan NJ Carl Shackford Busch Entertainment St Louis MO Red Sigle Electronic Data Systems San Diego CA Svein Sire Alcatel Stk Bedriftssystemer Oslo Norway Glenn Soltau Black Dot Graphics Crystal Lake IL Ted Sowinski CNA Insurance Companies Chicago IL Steve Stevenson FMC Corp Dallas TX Clive Stirling Mentecaptus Epsom Surrey England Steve Taylor Distributed Network Associates Inc Greensboro NC Lee Tollett M I Drilling Fluids Inc Houston TX Rodger Van Buskirk Rockwell International Seal Beach CA Jim Walker Triangle Universities Computation Center Research Triangle Park NC Jerry Wetherington Northeast Regional Data Center Gainesville FL BARR RJE Notes S 2 1 5 Acknowledgments RJE Concepts s da3u09 JfH Z With an IBM compatible personal computer PC and BARR RJE you can access large host computers or mainframes with powerful computer languages large databases and increased computational capacities from your office classroom lab or field station This chapter briefly discusses R
200. OD 00 00 00 00 00 00 00 BARR RJE 105 Example 5 PCL Reset Commands When network printers are shared by other users on the LAN it is a good practice to reset the printer before and after each job You also might want to use reset commands when you use the form overlay feature This example shows the reset commands for PCL printers such as an HP LaserJet HEX 1B 45 00 00 FF 1B 45 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 n o 2 E a 3 G n a gt oa EJ SEND1 SEND2 Devices The SEND devices allow you to route files from the PC to a selected destination device The most common destination for a SEND device is the host computer You can enable or disable these devices from the Devices and Printers menu When a SEND device is enabled it displays on the Assign Devices screen and on the command menu of the Operation screen For example to send files to the host you would assign SEND1 RD1 See sections 10 3 and 21 4 for more information about using the SEND devices SEND Device Menu gt From the Devices and Printers menu select a SEND device A list of options displays Devices and Printers SEND1 Use this device Delete this device Escape Selection l gt The same choices display for each SEND device 106 8 9 SEND1 SEND2 Devices Use this dev
201. OM destinations route data to a serial port device attached to the COM1 COM2 COM3 or COM4 port For example you can attach a serial printer to COM and assign PR1 COM1 Serial ports also can be used as sources You can enable the serial devices from the Devices and Printers screen as described in section 8 4 COMMAND The command device is a special destination for routing commands to the host computer from the PC keyboard by assigning KEYBOARD COMMAND The command destination is enabled automatically You cannot remove it from the destination list 158 10 3 Source and Destination Devices RD1 RD4 The RJE reader routes files to the host For example set SEND1 RD1 to submit a job to the host You can enable the reader devices from the RJE Description screen as described in the Barr Host Definition Guide SPOOL The spool device routes files to the print spool directory For example set PR1 SPOOL to direct files from RJE printer 1 PR1 to the print spool Files in the print spool queue are directed to printers by the source devices SPOOL1 to SPOOL8 See section 10 7 for an example _ A 2 2 5 S o D 2 The spool device is enabled by default You can disable it from the Print Spool Description screen as described in Chapter 9 NET1 12 NET devices route files to printers on a local area network NET devices support three types of network printing Most networks support redirection of L
202. Options The options on the first half of the Advanced Spool Options screen control print spool operation Control spool with Choose whether the file form name or FCB name controls spool file printing The specified file attribute must match the corresponding attribute on a spool printer before the file can print The control name displays between the state and class columns on the Print Spool screen This column is also called the spool control column The control column heading matches your selection for this option i o N o a i A a oa Formname Default On the Print Spool screen the control column heading is set to Form and the form name for each file displays in this column Typically the form name indicates the type of paper the job requires When the spool printer s form name matches a file s form name and other spool criteria match the job prints FCBname On the Print Spool screen the control column heading is set to FCB and the FCB name for each file displays in this column Typically the FCB name indicates the job format such as the number of lines per inch When the spool printer s FCB name matches a file s FCB name and other spool criteria match the job prints Display FCB Form name on spool control screen You can display both the form name and FCB name on the Print Spool screen The PC operator might find it useful to see both names However only the name specified
203. PC console when files are received Example 4 Extract the File Name from the File In some cases you might want to name a file by extracting text from within the file For example you might want to use the job name that displays on the file s banner page as the file name You can extract the name with the from file selection for Ending of file name 1 Select PR2 as the data source 2 Select FILE as the destination The file name screen displays 170 10 5 Assigning a File as a Destination Assign Devices Beginning of file name C STUDY5 Ending of file name is from file New File Log Enter character 3 Enter the Beginning of file name including the directory path In this example the path is C STUDY5 Include a backslash at the end of the directory name 4 For Ending of file name select from file 5 Use the default options New File and Log 6 Press Enter An additional entry line displays for specifying the location of the name text _ A 2 5 i S o 77 Assign Devices Beginning of file name C STUDY5 Ending of file name is on line 2 in columns 1 to 8 Enter number 7 Specify where the name is located in the file by entering the line number and the beginning and ending column positions When you press Enter the Assign Devices screen displays the Beginning of file name in parentheses after the source nam
204. PDIR and the Barr form is combined PC with Barr software FCB Name ca UCS Name Copies Job Name Form Name FCB Name UCS Name Copies Mainframe LPI LPF CC Stops Barr Forms input at the PC CC Stops CC Carriage control Figure F 1 BARR RJE combines information from the host PDIR record and the Barr form to provide form information for the file You can use the PDIR information with other Barr software features You can use the form name FCB name job name or UCS train name to load a form overlay You can use the form name FCB name or job name to name the PC file 516 F 2 Using SETUPHDR with Edit Forms If you use the print spool feature you can display the form name FCB name and number of copies on the Print Spool screen Operating Systems that Support SETUPHDR You can use SETUPHDR with any of these operating systems MVS JES2 XA MVS JES2 ESA a MVS JES3 VSE POWER VM RSCS When to Use SETUPHDR Use the SETUPHDR feature if any of these conditions are true You need file format information but cannot obtain it from the host You want the host to provide the UCS train name or number of copies The form name FCB name and job name are available from other sources but PDIR is the only source for the UCS train name and number of copies You need a reliable job name The job name provided by using HASP190 with FCBLOAD might not be reliable
205. PT1 to LPT3 with device drivers although some networks support redirection of LPT1 to LPT12 On the Novell network you can use NET devices to route files to Novell print queues On the TCP IP network you can use NET devices to route files to TCP IP LPR UNIX print queues When you assign a NET device that writes to a network print queue the network queue and server names display on the Assign Devices screen You can enable the NET devices from the Devices and Printers screen as described in section 8 5 BARR RJE 159 ET Assigning a Printer as a Destination If you want all data from a given source to write to a single printer you can dedicate the source device to a printer For example you can direct all the output from RJE printer 2 PR2 to a PC printer connected to LPT2 by assigning PR2 LPT2 Follow the steps below to make this type of assignment Assign Devices SEND1 RD1 SEND2 gt SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PR2 SUSPEND PU1 SUSPEND SPOOL1 LPT1 4 2 gt 7 i K Select SOURCE DESTINATION Escape Selection l gt 1 Select the source in this example PR2 and press Enter A list of destina tions displays Assign Devices DESTINATION FILE SCREEN NUL SUSPEND LPT1 LPT2 COMMAND RD1 SPOOL Selection tJ 2 Select the destination in this example LPT2 When you press Enter the screen reflects your selec
206. PUT statement is useful when other methods for obtain ing print instructions are not available Do not confuse the Barr OUTPUT statement with the JCL output statement which has a different purpose If the data source is a host computer you usually can use options such as the JES2 HASP190 message or SETUPHDR PDIR record to obtain this information The OUTPUT statement is not valid for the SENDn or LANn devices Note To use this feature you must change the program that pro duces the data so it adds the OUTPUT statement to the data file No Default The OUTPUT statement is not used Yes The information from the OUTPUT statement is extracted from the file and stored in the spool header Remember to include the OUTPUT statement in the file before the file is received to the PC When you enable the OUTPUT statement all lines up to and including the OUTPUT statement are deleted from the file To prevent data loss put the OUTPUT statement at the beginning of the file before any data BARR RJE 187 4 2 gt 7 i K Note If the file does not include the OUTPUT statement all data from the file is deleted and a warning message displays on the console In the OUTPUT statement the word OUTPUT must begin in column 1 column 7 must be blank and the keyword for the first option must begin in column 8 The statement must fit on one line in the file it cannot wrap to the next line If the file s ma
207. R1 RD1 from remote PR2 RD2 CON COMMAND How to Connect the Host and Remote Use any of these procedures to establish data communication BARR RJE 457 Remote and host operators establish voice contact by telephone Both operators then switch their modems from Talk to Normal a One site sets its modem to autoanswer The operator on the other terminal makes the call When the modem answers with a high pitched sound the operator sets the modem from Talk to Normal a Use a synchronous modem eliminator SME cable to connect directly to the mainframe as described in the Barr adapter manual You can order an SME cable from Barr Systems a i 2 Z lt x o Z o N 458 26 4 Assuming the Host Communication Role A Remote Commands The mainframe job entry system JES2 JES3 or VSE POWER views the Barr PC as a remote dumb terminal This appendix provides a quick reference to the most used JES2 JES3 and VSE POWER remote commands For more information about these commands see your IBM manual or consult your host programmer EAJ JES2 Remote Commands JES2 operator commands allow remote terminal operators to communicate with the JES2 system This section lists the most used JES2 remote commands JES2 Commands Command A release B backspace C cancel D display E restart F space forward H hold I interrupt L list N repeat 0 release P purge R route
208. S JES2 operating system When either of these choices is used without FCBLOAD you must define printer forms in the Barr software If HASP190 FCBNAME is used with FCBLOAD as described later in the Special Use note you do not need to define forms ob oo im gz i gt an Both HASP190 selections provide the same information form name FCB name and job name but your selection deter mines how you must name the forms in the Edit Forms table If you select HASP190 FORMNAME forms must be named to match the form name supplied by the message If you select HASP190 FCBNAME forms must be named to match the FCB name provided by the message See Chapter 13 Printer Forms for more information about defining forms During software operation if no matching form is found in the Barr Edit Forms table the software attempts to load the standard form STD If STD has not been defined in the table BARR RJE uses the form from the previous job To enable the JES2 HASP190 message include the parameter SETUPMSG for JES2 XA or SETUP MSG for JES2 ESA in the Remote Definition Additionally you must change the work selection criteria for each printer stream to enable all files to be received automatically regardless of their form name or BARR RJE 285 FCB name If you use HASP190 FORMNAME eliminate F for form from the work selection criteria with the JES2 Set Printer command T PR1 WS F If you use
209. S2 If your host system is MVS JES2 the default commands might be sufficient Common JES2 commands used for special forms printing are discussed at the end of this section BARR RJE 239 oo im 53 aJ mn i 3 a Printer Forms Commands Sent to Host Commands sent when form mounted P PRn E PRn Commands sent when printer started T PRn F ffffffff S PRn Commands sent after HASP190 or 1Q40A message S PRn Enter character The commands on this screen are outlined briefly below See the next section MVS JES2 Special Forms Printing for a detailed description of the commands P PRn Drain the printer a E ras o po a Gr _ E PRn Restart the job on the printer T PRn F ffffffff Set the form on the printer S PRn Start the printer 240 13 5 Printer Forms Commands Sent to Host Example 2 Commands for MVS JES3 Replace the default Printer Forms commands with the appropriate MVS JES3 commands Sample commands are shown below See your IBM JES3 documentation for a description of the available commands Printer Forms Commands Sent to Host Commands sent when form mounted X WIR OUT PRn F ffffffft Commands sent when printer started Commands sent after HASP190 or 1Q40A message Enter character _ oo im 53 o Bal i 3 a The commands on this screen
210. S2 ESA specify SETUP PDIR on the Remote Definition RMTnnnn statement Chapter 1 of the Barr Host Definition Guide discusses the JES2 Remote Definition 2 Enable Mount forms by in the Barr software Next instruct the Barr software to use the SETUPHDR information to load or mount a Barr form from the Edit Forms table The Barr form provides the format information for the file You can load the form with the Mount forms by option See section 18 2 Tuning and Global Options Printer Control for more information about this option For the SETUPHDR feature you must set Mount forms by to SETUP PDIR FORMNAME or SETUP PDIR FCBNAME When a file containing PDIR information is received either of these choices cause the software to automatically load the appropriate Barr form 3 Create the Barr form Finally you must create the form in the Barr software If your printer does not need the format information lines per form lines per inch and carriage control stops you can skip this step but you might want to set Disable form mount error messages to Yes on the Printer Control screen to prevent error messages from displaying Z i E i E L L Use the Edit Forms feature to create forms Select Printer Forms from the Installation Description menu In the form definition assign each form 518 F 2 Using SETUPHDR with Edit Forms a name and enter format information See Chapter 13 Prin
211. SCII to EBCDIC and EBCDIC to ASCI translation of characters You also can change the character set language from English to one of several other languages See section 18 1 Printer Control Select options that control printer forms and form overlays and affect the print data See section 18 2 BARR RJE 271 Reader Control Set the line length for the RJE reader and choose whether ASCII control characters will be included in data sent to the host computer See section 18 3 Modem and Line Control Set miscellaneous options that affect communications including delayed communications startup Other options are specific to the SDLC or 802 2 communication links or connection via BARR GATEWAY See section 18 4 Restart Actions Enable options that determine what action BARR RJE takes when the communications line becomes idle or a restart condition occurs See section 18 5 Trace and Memory Options Enable or disable the line trace and adjust memory options See section 18 6 Display and Disk Options Set options that affect the PC display and disk performance See section 18 7 a i A i o r Session and Security Options Set options that enable access to the Installation Description screen Receive Mode screen and various BARR RJE sessions See section 18 8 Miscellaneous Options Adjust other options that affect software operation See section 18 9 Escape Select Escape or press the
212. T Devices 91 Printer Control Data for Network Printers 04 92 8 6 Choose Printer Type 2 0 eee cece een eens 92 Printer Types with Special Requirements 94 Lines per form and Lines per inch 0 200 e ee eee 95 8 7 Forms OVET AY n atn hana aai a a e tides ew eres Huh tee 99 Naming the Overlay File 0 0 0 0 ee eee eee 99 Using Electronic Forms 0 0 0 c ee cece eee ee 99 Loading Printer Control Data or Printer Resources 100 Overlay Files for PostScript Printing 00 100 Creating an Overlay from Several Files 100 8 8 Printer Control Data 0 cc eens 102 Control Code Entry Screen 0 00 c eee eee eee 102 Printer Control Data Examples 0 000000 104 8 9 SENDI SEND2 Devices 0 00 0 ce cece eens 106 SEND Device Men s arnie n a eeee nee 106 8 10 LANI LAN4 Devices mooner eri een ccc eee 107 LAN Device Menu sie eni sue ke sae E aed SABA Beenie skies eden 108 BARR RJE vii LAN Connection Options 0 0 02 cece ee eee eee 109 Error Handling for LAN Connections 0 0205 111 Using the Barr Move Command 00 0 eee eee 111 LAN Connection Example 00 00 pe EEA eee 112 8 11 NOVELL Queue Devices nnan ec eee eee 113 Novell Queue Devices Menu 00 ce cece ee eens 114 Sour
213. T1 if a file transfer fails the file state is set to Retry and the priority is decreased by 1 The print spool tries to print the file again after the interval you specified on the NET Options screen Disposition Indicates whether the file will be deleted or retained after printing If the file is to be deleted a hyphen character appears to the right of the file state If the file is to be retained a blank character appears to the right of the state Files are retained in the directory specified on the Print Spool Description screen If a retain directory name was not specified files are retained in the root directory Form Form name The form often indicates pre printed paper forms that must be mounted on the printer You can use this attribute to control which spool printer is selected to print a file FCB FCB name Display of this attribute depends on your Print Spool Description settings N A mz 3 N g 2 So 3 D S Class A one character alphanumeric printer class that you can use to group files You can use this attribute to control which spool printer is selected to print a file You can use Barr software options to assign a class value to files received from the host Files without spool headers that are copied into the spool directory from DOS are assigned class Z Prty Indicates the print selection priority Values range from 0 to 9 with 9 as the highest priority BARR R
214. TIVE ASIS NO CCTL YES CKPTLINE 0 10 41 14 HASP603 CKPTPAGE 10 CMPCT YES COMPRESS YES 10 41 14 HASP603 COMPACT COMPACT1 CREATOR DEVFCB EJECT YES 10 41 14 HASP603 FCB 8 STD FCBLOAD YES FORMS STD JOBNAME 10 41 14 HASP603 LIMIT 0 LRECL 132 PRMODE LINE 10 41 15 2 HASP603 PRWIDTH 132 QUEUE AJ RANGE J1 32767 10 41 15 5 HASP603 ROUTECDE R122 SELECT PRINT1 SEP YES 10 41 15 HASP603 SEPDS NO SETUP HALT SPACE SUSPEND YES 10 41 15 HASP603 TRACE NO TRANS DEFAULT UCS 0 STD 10 41 15 E HASP603 VOLUME WRITER 10 41 16 HASP603 WS W Q R PRM LIM F FCB UCS 10 41 16 5 cc The most important information in the listing has been underlined lt x although the other parameters can also be important The STATUS parameter can have several values These are the most common STATUS DRAINED Printer has been halted PR1 is required to start it again STATUS INACTIVE The printer is started and ready but no jobs are printing 466 A 1 JES2 Remote Commands DF STATUS ACTIVE A job is currently printing The FORMS and QUEUE parameters show the current setting for form and class which are analogous to the form and class setting on the printer line in the Barr print spool In this example the form is STD and classes allowed are A and J The final key parameter is WS the work selection criteria which is a list of criteria that influence which jobs will be allowe
215. TPUT CCTEST OUTGRP 2 1 1 BURST NO FCB 14 29 08 HASP686 FLASH FORMS CTST HOLD NONE 14 29 08 HASP686 HOLDRC OUTDISP WRITE PAGES 14 29 08 HASP686 PRIORITY 12 PRMODE LINE QUEUE A 14 29 08 HASP686 RECORDS 15 OF 15 ROUTECDE R122 14 29 09 g HASP686 SECLABEL TSOAVAIL NO UCS 14 29 09 g HASP686 USERID BARRGAT WRITER 14 29 09 JOB16250 HASP686 OUTPUT CCTEST 14 29 09 amp JOB16250 HASP686 OUTPUT CCTEST OUTGRP 1 1 1 BURST NO FCB 14 29 09 ms HASP686 FLASH FORMS STD HOLD NONE 14 29 10 s HASP686 HOLDRC OUTDISP WRITE PAGES 14 29 10 E HASP686 PRIORITY 11 PRMODE LINE QUEUE A 14 29 10 oc HASP686 RECORDS 68 OF 68 ROUTECDE R122 14 29 10 x HASP686 SECLABEL TSOAVAIL NO UCS 14 29 11 HASP686 USERID BARRGAT WRITER 14 29 11 As the resulting messages show the CCTEST job has two outputs one with FORMS CTST and QUEUE A and one with FORMS STD and QUEUE A You can also tell from this listing if the job has been put on hold 468 A 1 JES2 Remote Commands E Restart The E command restarts the job currently printing or punching The operator can restart job output when print or punch output becomes damaged The E command s single operand is the device to restart Format Enter the E command as follows E dev where dev is the device This command terminates current printing or punching and re queues the print or punch output Ex
216. Tables 276 Edit Translation Tables 000 00000 c cece ee eee 277 Assign Translation Tables to Devices 00 280 18 2 Printer Control meeue Seripa cee ee eee eens 280 Options for Printer Forms ir Estutu Tn aD A 281 Options for Forms Overlay 0 0 0 eee eee eee eee 287 Other Print Options in ON AEEA ee eee 290 3270 Printer Options 0 cece cece eee 292 18 3 Reader Control iaee eek Shi Pct cet ik Be nk ee ee a 292 18 4 Modem and Line Control 00 00 0000 cee ee eee 294 Options for All Communication Links 04 295 Options for the SDLC Link ariera 2 0 00 0 eee eee eee 297 Options for the 802 2 Link 02 2 eee eee eee 299 Options for the Gateway Connection 0 0 008 300 8 5 Restart ACtOns 2a 3 S ued dee ios eed ed ee ey bees 301 BARR RJE xi 18 6 18 7 18 8 18 9 Chapter 19 19 1 19 2 19 3 19 4 Chapter 20 20 1 20 2 20 3 Chapter 21 21 1 21 2 21 3 21 4 Trace and Memory Options 0 00 00 000 000 303 Display and Disk Options 0 0000000000 307 Session and Security Options 0 0 0 0 00004 310 Miscellaneous Options 0 0 0 0c ee eee eee eee 313 Exit and Save Changes 00 0 cece ee ee ene 315 Exit and Save Changes Screen 0 00000 315 Exit Options Screen 00 0 0 eee
217. XMT transmission queue and options are CLASS DISPOSITION or PRIORITY Example A LST1 CLASS A sets queue 1 to class A D Display Device Characteristics CA o lt x The D command displays device characteristics Format D device where device is LST list queue PUN punch RDR reader or XMT transmission queue 456 A 3 VSE POWER Remote Commands Example D LST1 displays all jobs in queue 1 Inquire Displays the status of a line device or LU Format I options where options can be ALL DEV name luname or lineaddr for bisynchronous lines Examples I ALL displays the status of all devices LUs and lines I DEV PRT1 displays the status of PRT1 P Stop Task The P command stops a running task Format P task where the task runs on L Tn list queue or PUN punch Example P LST1 EOJ stops the task in queue 1 at the end of the job R Release Moves devices from the hold state to the ready state gt D 3 2 D o 3 3 D Ss 2 7 BARR RJE 487 Format R device options where the device is L Tn PUN or RDR Example R LST1 releases printer 1 from the hold state S Start Device The command starts a device or task Format S device option where device is LSTn PUN or RDR and option is CLASS DISP disposition PRI priority DEST destination and so forth Examples S LST1 CLASS A starts CLASS A t
218. a a Enter number Assume you have prepared the file F WORK DATA to send to the mainframe To put the file in the LAN connections directory enter this command at the DOS prompt move work data host When the software checks the directory at the next 30 second interval it finds the file and adds the start and end JCL files as follows f jcl start job host data jcl end job The combined file is sent to the mainframe on reader 1 RD1 Because a retain directory is defined BARR RJE automatically moves the file F HOST DATA to the directory F HOSTSAVE If a file named DATA already exists in the F HOSTSAVE directory the software assigns the file a unique numeric file extension EXE NOVELL Queue Devices You can receive data from Novell NetWare job or print queues if you set the options described in this section Network Queues and Servers On the network files are stored in queues until they are routed Queues reside on network file servers The Barr software must access the network queues to receive the waiting files To do this the software performs the BARR RJE 113 function of a network queue server It services the queues by logging into the file servers and retrieving the files You can direct data received from the Novell queues to printers or route it to the mainframe as jobs Network Connections The Novell network allows a PC to connect to a maximum of eight dif
219. a Start of file string A string that begins in the first position of the table is sent to the printer at the start of every file If you do not want to use this type of string begin your table entries after the first two pairs of zeros 00 00 End of file string A string that starts with FF is sent to the printer at the end of every file You might want to use a string beginning with FF to reset the printer after each job especially if the printer is shared by the Barr PC and users on the network BARR RJE 103 n o 2 E a 3 G a a Fq oa a Printer form string Strings that start with the bytes 01 to FD are sent to the printer when they are referenced by a Barr printer form This lets you use a Barr form to control features such as landscape and portrait page mode on a laser printer See sections 13 2 and 13 3 for more information about linking printer control data to Barr printer forms Serial port input header A string beginning with FE is called a serial port input header and is used differently than other control strings Rather than being sent to the printer as control codes this string is appended to the beginning of all files input on the selected serial COM port You can use the serial port input header to include commands to be sent to the host or insert Job Control Language JCL so the file can be submitted to the host as a job If the header is composed of multiple lines indicate
220. abc You can use a file extension when you assign the file name or BARR RJE can automatically generate a numeric file extension When the destination is FILE you can include a file extension in the Beginning of file name or Ending of file name When the destination is FILE the software generates a file extension if both these conditions are met a You select New File or Replace Cond on the file name assignment screen The new file has no extension or a duplicate file name was found 166 10 5 Assigning a File as a Destination The software also generates file extensions for duplicate files for the LAN retain directory spool retain directory and NET device driver features BARR RJE generates file extensions to prevent it from overwriting files that have the same name In some cases the software assigns an extension to any file that does not already have one In other cases an extension is assigned only if a duplicate name is encountered The process for assigning file extensions is similar in both cases The software searches the destination directory to determine if any files have the same name as the new file If a duplicate name is found the numeric extension n 1 is assigned to the new file where n is the highest extension found for that file name For example BARR RJE assigns extension 001 to the first file 002 to the next file with the same name and so on _ A 2 5 S o D 2
221. able This means a printer reset string will not be sent to the printer before each file b Begin the landscape control string with the index 01 followed by the landscape codes and terminate the string with two pairs of zeros 00 00 c Begin the portrait control string with the index 02 followed by the portrait codes and terminate the string with two pairs of zeros 00 00 Your control data will look like this a E ras o p a Gr _ HEX 00 00 01 1B 26 6C 31 4F 00 00 02 1B 26 6C 30 4F 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 When a file requiring the form LAND is ready to print BARR RJE searches the Printer Control Data table for an entry beginning with the index 01 and sends the corresponding codes to the printer A similar process occurs when a file requiring the form PORTRAIT is ready to print The software searches the Printer Control Data table for an entry beginning with the index 02 and sends the corresponding codes to the printer 232 13 3 Using Printer Control Data with Forms EER Mount Forms During software operation you can use the Operation screen s Mount Forms command to select a form for an RJE print stream PR1 to PR7 Forms enable files received on the print stream to print in the correct format Use the Mount Forms command if either of these conditions is true m You are manually mounting forms fro
222. able Specifications for 25 Pin Serial Ports o o g pm pa 72 This type of printer cable is also called a null modem cable It has a D25 male connector that plugs into the printer and a D25 female connector that plugs into the PC serial port 498 C 2 Signals for 9 Pin Serial Ports Printer D25 Male Name Pin PRO GND 1 RXD 3 TXD 2 SIG GND 7 DTR 20 CTS 5 DSR 6 20 DTR DCD 8 PC Serial Port D25 Female Pin Name 1 PRO GND 2 TXD 3 RXD 7 SIG GND 5 CTS 6 DSR 8 DCD KEY Printer Cable Specifications for 9 Pin Serial Ports This type of printer cable is also called a null modem cable It has a D25 male connector that plugs into the printer and a D9 female connector that plugs into the PC serial port Printer D25 Male Name Pin RXD 3 TXD 2 SIG GND 7 DTR 20 CTS 5 DSR 6 DCD 8 PC Serial Port D9 Female Pin Name 3 TXD 2 RXD 5 SIG GND 8 CTS 6 DSR 1 DCD 4 DTR o N o 2 ms i e 53 o g ix o BARR RJE 499 Notes o o o 2 i am pa So A T D nan o 500 C 4 Printer Cable Specifications for 9 Pin Serial Ports D Printer Test The BARR RJE reference files usually installed in C BARR REF include a printer test file The printer test file helps you diagnose the following problems a Printer incorrectly connected to PC Incorrectly set p
223. able of LOGMODE definitions multidrop line See multipoint line multileaving In HASP communications a BSC com munications protocol that allows one communications link to send data in both directions at the same time In each direc tion multiple streams of data can flow to several printers or disk files multiple logical unit RJE The most sophisticated RJE protocol supported by SNA communications It enables several logical units to simulta neously send and receive multiple streams of data multiple session RJE See multiple logical unit RJE multiplex To concentrate multiple streams of data on one medium multipoint line In SNA and 3780 communications a line that has more than one physical unit communication with the host computer These physical units share the line but only one unit sends on the line at a time Also called multidrop line multistation adapter unit MAU A centrally located unit to which token ring nodes are connected The MAU repairs the ring by removing non func tioning nodes from the ring and thus maintains the integrity of the ring even if there is a malfunction 542 Glossary MVS Multiple Virtual Storage operating system A large IBM operating system that oper ates on System 370 3081 and 3091 pro cessors NAK In bisynchronous communications a Negative Acknowledgment character used to indicate a problem with receiving a message NCP In SNA communications a program t
224. ables BARR RJE to preserve any unique form information in a separate spool header for each file The spool header contains a group code that enables BARR RJE to group these files and print them in the correct order If you change attributes for one of the files in such a group BARR RJE applies the change to all of the files EZY Printers Command When you start BARR RJE the spool printer attributes get set to the values you specified on the Printer Initialization screen You can use the Printers command to change printer attributes that control how files are directed to spool printers For example if you load pre printed forms for printing checks on printer LPT1 change LPT1 s form attribute to CHECKS on the Print Spool screen This tells BARR RJE to route files with the form name CHECKS to LPT1 It also prevents files that require other forms from printing on LPT1 while the special forms paper is loaded You can change a spool printer s state form and class Follow these steps to change printer attributes 1 Select P for the Printers command a 5 The cursor moves to the list of printers at the top of the screen and the So message Spooling paused flashes in the lower left corner of the screen to s remind you that all spool activity stops while you are using the Printers a N command E a Printer File State Form Class Prty Copies Size Units Status ey gt LPT1 Ready STD 1 415 busy LPT2 Ready STD 2 0 busy D
225. above the cursor show the form line numbers Enter carriage control characters 1 9 A B or C 000000000111111111122222222223333333333444444444455555555556666666 123456789012345678901234567890123456789012345678901234567890123456 1 1 1 1 1 1 1 1 1 1 1 Enter character 5 Type 1 stops at one inch intervals for the top of each label 6 When you press Enter the list is updated to reflect the new form definition 228 13 2 Edit Forms EER Using Printer Control Data with Forms Edit Forms select one Escape CHECKS PERF STD STD2 LABELS Selection l gt You might want to specify other printer commands for each form You can use printer command sequences to select compressed or standard print characters or change the typeface on either line or laser printers You also can choose portrait or landscape page orientation on laser printers oo mz 53 o Bal i 3 a Commands are stored in the Printer Control Data table defined for LPT COM and NET devices under Devices and Printers The two digit Printer control index in the form definition references an entry in the Printer Control Data table When a job requiring a form is ready to print the software sends the form information to the printer followed by the printer control data that corresponds to the index specified in the form definition Printer Control Data Processing If you use beginning or
226. acter to occupy that position For example FORM JUN 9 406 24 1 Managing Print Spooling matches any form that begins with JUN and has a 9 as the sixth character An in the form name allows any character to occupy that position and all remaining positions in the name or extension For example FORM MAY matches all form names starting with MAY For more information about DOS wildcards see the discussion about global file name characters in your DOS manual If the form attribute field contains only an asterisk all files can print regardless of their form name Class A one character alphanumeric printer class used to control file selection For a file to print the printer s class must match the file s class You can enter up to five classes for each printer Each of the five characters represents a separate class If you do not specify a printer class class is not used for file selection Units Cumulative total number of lines or pages printed You can control whether this column displays the number of lines or the number of pages with the Display count of lines or pages option Status Physical printer status See section 20 2 for more information about the physical printer status File Attributes The spool header added to each file contains attributes that describe the file and specify how it is to be printed N gt mi 3 N 3 A 3 o S i Changing and Saving Attribut
227. adapter meets this requirement LAN support program compatible with your adapter Barr Systems 802 2 LLC support uses IBM s LAN Support Program This program originally used two drivers DXMAOMOD SYS and DXMCOMOD SYS which you added to the CONFIG SYS file on each PC This program supported any token ring card that used the Tropic chipset for network communications including 3Com Intel and Olicom Now the typical LAN support is through the Network Device Interface Specification NDIS interface which replaces DXMCOMOD SYS with DXMEOMOD SYS Any token ring or Ethernet card with an NDIS driver can support the 802 2 LLC protocol To install the NDIS interface use the DXMAID install program supplied with the LAN Support Program You also need a board specific driver which is usually included on the board s driver disk The IBM LAN Support Program is not in the public domain and must be purchased from IBM In some cases vendors now support running their 1 1 Equipment Checklist own version of LAN support For instance Madge supplies the SMART interface with their token ring boards See your vendor for information about the necessary drivers _ 5 i 2 ix 5 A LAN adapter also is required when BARR RJE connects through BARR GATEWAY on the LAN BARR RJE supports the LAN software interfaces 802 2 LLC NetBIOS Novell IPX and TCP IP for gateway connections Modem For SDLC or X 25 host connections
228. age control stops You can also link forms to printer control data which can provide additional printer commands See Chapter 13 Printer Forms for more information about defining Barr forms and mounting them from the Operation screen 526 F 4 Using Edit Forms with Manual Mount Forms Warranty Information Software License Agreement Single User Barr Systems Inc Barr Systems grants and Licensee accepts the terms and conditions of this agreement which provide a non transferable and non exclusive license to use the software program Licensed Software enclosed herewith on one single user workstation so long as Licensee complies with the terms of this agreement Licensee s rights hereunder are those of a licensed user only and the Licensed Software shall at all times remain the property of Barr Systems Licensee agrees to pay for licenses for additional user copies of the Licensed Software if Licensee intends to or does use it on more than one single user workstation at a time Acceptance Licensee understands that the use of the Licensed Software or the use of any of the computer hardware the Product Hardware purchased from Barr Systems constitutes acceptance of the terms and conditions of this Software License Agreement and this Limited Warranty with respect to the Product Hardware and the Licensed Software Maintenance and Limited Warranty The Licensed Software and the Product Hardware ar
229. al options affect the PC display and disk activity gt From the Tuning and Global Options screen select Display and Disk Options Display and Disk Options Number of minutes before screen save 9999 Password for screen lock Fast scroll used on CGA color monitor adapter No Display error messages when invalid DOS file name characters are replaced Yes Use VERIFY OFF to improve disk performance Yes Commit files to disk every 999 seconds Enter number Number of minutes before screen save Specify the number of minutes the screen can display before the display is cleared Use this feature to increase the screen life of the PC monitor If the screen display is constant the PC screen life BARR RJE 307 a i A i o might be shortened especially in cases where the software runs 24 hours a day The screen clears after the specified time has elapsed You can redisplay the screen at any time by pressing any key on the keyboard For example if you specify a period of 10 minutes the screen will blank after displaying for 10 minutes The software continues to operate after the screen is cleared You can immediately activate the screen saver at any time if you do not want to wait for the specified time to elapse Press to immediately clear the screen To reactivate the screen press a key and then press at the password prompt To set the display to constant screen
230. ala National Forest In a natural semitropical wooded setting the main pool which is about 175 feet long 25 feet wide and 6 feet deep is irregularly shaped with sandy bottom and banks Most inflow to the springs measured between 11 6 and 19 9 cubic feet per second comes from three major boils or openings numerous smaller boils and additional smaller springs immediately south Water from Fern Hammock Springs flows down Juniper Creek to Lake George in the St Johns River basin 10 miles away Photography by James Valentine Florida Images of the Landscape March 11 1997 Preface BARR RJE enables you to perform SNA file transfer remote job entry and remote printing from a PC You can use BARR RJE even if you do not fully understand remote communications This manual describes how to install and use BARR RJE software on your PC and explains the fundamentals of data transfer between the PC workstation and mainframe computers Whether you have technical or non technical experience BARR RJE enables you to transfer data quickly and easily The installation and operation instructions in this manual guide you through each step Chapters are organized to reflect the logical sequence to follow when you install and operate the software Chapter 1 describes equipment requirements and package contents Review this chapter to ensure that you have everything you need before you begin m Chapters 2 and 3 present basic remote communications co
231. ally booklet 4 Continue option 160 175 Control characters 184 495 Control codes 489 ASCII 293 See also Printer control data translating 274 275 491 Control file See also Spool Control Files TCP IP 86 Copies See also File attributes JCL 519 Novell NetWare queue 117 OUTPUT statement 187 PDIR 516 See also Printer attributes SETUPHDR 283 spool 519 spool header 509 CRC 25 CSU DSU_ 26 CTR file extension 441 Ctrl Function Key Definitions screen 254 255 CTS See Clear To Send CTS delay option AT modem 210 554 Index Customer support iii Cyclical redundancy check CRC 25 367 802 2 errors 382 SDLC errors 379 X 25 errors 385 D Danish Norwegian character sets 277 Data compression 25 decompression 25 rate 14 receiving ASCII 490 sending ASCII 490 Data bits serial port 63 64 Data compression using tabs 290 Data Control Block DCB 183 Data conversion serial port input 451 Data format mainframe and PC 177 reader 292 Realia COBOL 181 See also Receive mode Data Link Control DLC Protocol 16 Data translation 273 Data Set Ready DSR ignore DSR 0 297 serial port 64 65 497 499 Status Line 325 Data Terminal Ready DTR 24 drop on exit 298 modem signal 204 serial port 13 499 DATA100 tape support 30 Dataphone 2224B modem 203 204 options 207 Datapoint 1800 remote 457 Dataproducts Interface 12 22 32 59 93 See also DPI Dataproducts printers 93 BP1500 model 58 Date and Time console message 3
232. ame select jobname 5 Use the default options New File and Log When you press Enter the Assign Devices screen displays the Beginning of file name in parentheses after the source name 4 2 gt 7 i K Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PR2 C JOBS PU1 SUSPEND SPOOL1 LPT1 Continue Escape Receive mode Options Help With this assignment if you receive a mainframe file named JOB49127 that has a job name of PAYROLL the PC file name will be C JOBS PA YROLL OO1 If you omit the backslash at the end of C JOBS the file name would be C JOBSPAYR 001 Example 2 Route Output to the Network Using Form Name and Job Name If you use both form name and job name to name files you can group mainframe output on the PC or the network For instance the selection Ending of file name is formname jobname allows you to route files to different subdirectories by their form name You can use this feature to route output files to the user who submitted the job In this example the user name is used as the form name and a subdirectory named for each user is created on the network The job name is used as the name of the file Assume output will be routed to three users named Ann Gary and John Your first step is to create a subdirectory for each of these users on the network F ANN F GARY and F JOHN 1 From the Assign Devices screen
233. amples E PR1 stops the current job printing on printer 1 and re queues the entire print output E PUL stops the current job on punch 1 and re queues the entire punch output F Space Forward The F command advances the job currently printing or punching Operators can advance the job a specified number of pages or cards or to the end of the current dataset For example they can forward space over a long program listing to print only the program s output dataset gt 3 2 o o 3 3 D 2 z The F command has two operands The first operand identifies the device The second operand gives the number of pages or cards to forward space or tells the device to forward space to the end of the current dataset When the operator forward spaces printed output the F command counts page ejects that is skips to channel 1 not physical pages If no pages eject in the dataset being printed F forward spaces to the end of the dataset BARR RJE 469 Format Enter the F command as follows F dev y where dev is the output device and y is either a number indicating the number of pages or cards to skip or the letter D to forward space to the end of the dataset If the device encounters the end of a dataset during a forward space printing or punching resumes at the beginning of the next dataset If the operator does not specify a y operand a 1 is assumed Examples F PR1 forward spaces the output on
234. an operand BARR RJE 481 gt J 3 2 o o 3 3 D 2 z F Modify The F command dynamically alters the status of jobs system parameters or JES3 resources Format Enter the F command as follows F x X MODIFY x x Examples F J nnnn R releases a job on operator hold F J nnnn C cancels a job unless the job is on hold F J nnnn H holds a job in the output queue F U J nnnn NH Y changes a job s hold status to on hold NH Y F U J nnnn NH N changes a job s hold status to released from hold NH N Inquiry The I command displays status information about jobs devices queues or messages CA D c lt x Format Enter the I command as follows I xx INQUIRY x x 482 A 2 JES3 Remote Commands Examples I Q displays the first 10 jobs N 10 is the default waiting for action in the queue I Q N A11 displays a list of all jobs waiting in the queue I U J nnnn F nnnn N ALL displays the names of all jobs N ALL in the output service queue Specify the job name or job number in the J nnnn parameter and the form number in the F nnnn parameter I U J nnnn REQ ALL displays the processing requirements REQ ALL for the first 10 jobs in the output service queue Specify the job name or job number in the J nnnn parameter I U J nnnn REQ ALL DD SYSUDUMP N ALL displays the processing requirements REQ ALL and a summary
235. an outside line Phone numbers 9 1 352 555 1234 F 2 The dialing sequence for this example is as follows iz Character Function 9 Dial 9 reaches outside line f Wait for dial tone 1 Dial 1 long distance call Ignore 352 Dial 352 area code Ignore 555 Dial 555 Ignore 1234 Dial 1234 Modify options Choose whether to view or modify modem options No Default The Modem Options screen does not display Use default values for the modem options Yes When you select Yes the Modem Options screen displays You can view or modify the options 206 12 2 Modem Connection Screen EF Dataphone 2224B Modem Options This section describes modem options for the modem type selection Dataphone 2224B modem gt To reach the Modem Options screen set Modify Options to Yes and press Enter on the Modem Connection screen Modem Options Modem standard CCITT V 24 2400bps Connection Autodial Autodial retries 999 Wait for dial tone Yes Starting time Choice ook N 2 D 3 5 N 2 o 5 77 Modem standard Select one of these options to match your modem standard CCITT V 24 2400bps CCITT V 24 1200bps Connection Specify the modem connection type Autodial Default The modem dials the phone number and listens for a modem answerback tone Autoanswer The modem automatically answers an incoming call waits 2 seconds and sends the answerback t
236. an use the and characters according to the DOS wildcard convention Note If you enter a DOS wildcard and no matching files are found BARR RJE does not display an error message a Press to cancel the command and return to the Operation screen Example 1 Multiple Files To send two separate files named JOB1 and JOB2 separate the file names with a space Enter file names To combine files separate by a plus To start a new file leave a blank To cancel press Esc Files JOB1 JOB2 Example 2 Concatenated Files To send the files JCL DATAI DATA2 and TRAILER as if they were one combined file separate the file names with plus signs 340 21 4 Send Files Enter file names To combine files separate by a plus To start a new file leave a blank To cancel press Esc Files JCL DATA1 DATA2 TRAILER Example 3 Multiple Files with a DOS Wildcard To send all files that end with the extension JOB use the DOS asterisk wildcard Enter file names To combine files separate by a plus To start a new file leave a blank To cancel press Esc Files JOB Example 4 Concatenated Files with a DOS Wildcard To send the file named JCL followed by all files with the name DATA and any extension as one combined file separate the file names with a plus sign Enter file names To combine files separate by a plus
237. and Dialing Instructions for autodial modems and Interrupt Request Address and Loopback Test for the Barr communications adapter display only if your software has the SDLC or X 25 host connection a If you purchased software options other selections might display on your screen Separate manuals describe the other selections Minimum Configuration You can customize the options to suit your data transfer and printing needs The first five menu items are the most important and supply the minimum configuration required to operate the software RJE Description and Communication Link allow you to set up communication with the host computer and enable RJE printers punches and readers After you enter these settings you can test the connection with the host BARR RJE 49 Devices and Printers LPT COM NET SEND LAN allow you to set up PC printers and other devices m Print Spool Description contains options required for print spooling Assign Devices controls the flow of data into and out of the program It allows you to manage the devices defined by the previous four options and is the central feature for program operation The rest of the menu items allow you to set up other software features The requirements at your site determine which of these selections you need to enable E d o 77 i amp T 72 Use the last option on the screen Exit and Save Changes to periodically
238. and end of the file respectively 5 Press twice to return to the PRT menu 448 25 3 Operate the PRT Utility Load Spool Controls The Controls command lets you load change and save options for spool control files 1 Select Controls from the command menu Controls Modify controls Load controls Save controls 2 Select Load controls Load Controls Enter file greenbar ctr Enter control file to load 3 Enter the name of the control file to use for example GREENBAR CTR The default file name is SPOOL CTR After the controls are loaded you can change them if you need to as described in section 25 2 Submit a File to the Spool The Spool File command puts a file in the spool directory It uses the spool control options you specified with the Controls command 1 Select Spool File from the command menu Spool File Select file from list Enter filename N ol a Ss i vu Es Cc lt 2 Choose Enter filename Spool File Enter file FILEDESC LST Enter file to copy into spool directory 3 Enter the name of the file to spool or press to cancel A message notifies you when the file has been spooled BARR RJE 449 File C MISC FILEDESC LST has been spooled to C SPOOL FILEDESC LST Ok 3 Press or to return to the PRT menu
239. and or press a predefined function key Follow these guidelines when you type commands Separate multiple commands with a vertical bar Press to display the previous command m Press to exit Type a Command When you type a command a column counter displays in the bottom right corner of the screen Use the column counter and the following keys to position the cursor Home Move the cursor to the beginning of the line Move the cursor to the right Move the cursor to the left BCE End Move the cursor to the end of the line 5 D Insert text at cursor Delete character at cursor Enter Submit the command line to the host ee Backspace Backspace and delete Tab Tab forward Tab stops are at eight character intervals Ctrl 6 Ctrl Delete from the cursor to the end of the line Move forward one word BARR RJE 335 N o gt J eoj ps J amp m i 3 o 5 i o a i Wu c gt s c co rr N Move backward one word Esc Exit command mode and return to the Operation screen Clear the console portion of the screen Use a Predefined Function Key You can send a command to the host by pressing a function key When the command is sent it displays on the console A list of function keys with predefined commands displays at the bottom of the command screen To see additional predefined command descriptions press
240. anks as necessary Specify the maximum print position on a line If characters on a line exceed the specified maximum the software will wrap the extra characters to the next line as the file is received to the PC The default length is 255 print characters but you can customize this value for your application For example if data lines contain 255 characters but your printers support a maximum of 132 characters per line set this value to 132 ob oo im gz i gt an special Vertical Channel Select sets print column to zero This option applies only to RJE or 3270 data generated by the Xerox Printer Access Facility XPAF It controls whether RJE 3270 inserts a carriage return CR before Set Vertical Channel SVC commands No Default The software does not insert a carriage return before SVC commands Use this choice if the data file already includes a carriage return before each SVC command Yes The software inserts a carriage return before SVC commands which causes the print head on the printer to return to column 0 on the page before an SVC command is processed This choice might be required for data that does not already include BARR RJE 291 carriage returns in front of SVC commands If a carriage return is not issued before the SVC command the data on the next print line might begin in the middle instead of at the beginning of the line 3270 Printer Options These options do not appl
241. arameters Before you use BARR RJE you must configure the software s RJE Description screen and Communication Link screen parameters to match the mainframe s parameters The host VTAM communications programmer must describe your BARR RJE remote to the RJE system VTAM and NCP The Barr Host Definition Guide documents the parameters the host programmer and the BARR RJE installer must set Give one copy of the guide to your host programmer BARR RJE 19 Notes o E S wi pu B o m m 20 3 5 Host Parameters Chapter nE BARR RJE Features BARR RJE allows you to control communications activities for sending processing and receiving files It includes built in diagnostic tools and can support specialized applications with add on options A o gt J z gt e a m pag o 2 oO a ESH Printer Support Features BARR RJE supports high speed printing spooling and plotting Special features include printing on special forms and multiple printers High Speed Printing You can use BARR RJE with a variety of printers Print speeds on single and multiple printers range from 30 characters per second cps to more than 40 000 lines per minute Ipm BARR RJE can drive even the fastest laser printers at maximum efficiency from a PC Multiple Printers The SNA RJE Multiple Logical Unit protocol supports up to seven print streams Barr RJE allows you to direct print o
242. are described briefly below For a detailed explanation of JES3 commands see your IBM JES3 documentation X WIR Call the JES3 output service writer to drive the selected output device Alternatively this command might appear as CALL WTR OUT PRn F ffffffff Select the printer and set the form MVS JES2 Special Forms Printing This section introduces you to the common RJE printer states for JES2 and to frequently used printer commands This section is especially helpful to users who are new to remote printing Printer States At a given point in time a JES2 printer stream might be in one of five states BARR RJE 241 State Description Inactive Printer is idle Active Printer is currently in use Drained Printer is inactive and will not allow another print file to be printed Draining Printer is active and waiting for the end of the file currently being printed before it stops Halting Similar to draining Printer Commands The following sample JES2 commands show you how to display or change the state of an RJE printer In this example commands are shown for PR1 These commands will work for any print stream if you substitute the corresponding RJE printer number See Appendix A for a description of other JES2 commands a E ras o p a Gr _ P PR1 The P command sets an inactive or active RJE printer to draining When a printer is drained all print activity stops If the pri
243. arrow indicates the current file Move among file attributes by using or Change the file attributes Press to store the changes or press to cancel the changes Press once to return to the Files command menu or twice to return to the Print Spool screen A Rw oN o i i 72 pan i Q N Change Attributes for a Group of Files You can change the attributes for a group of files by first marking the desired files 1 Select a file using the keys A blinking arrow indicates the current file 2 Press to mark the files A checkmark displays next to marked files 3 Change the attributes for one of the marked files 416 24 3 Files Command 4 Press to store the changes 5 At the Apply changes to all marked files prompt select Yes 6 Press once to return to the Files command menu or twice to return to the Print Spool screen Delete a File or a Group of Files EYJ Sort Command Files are automatically deleted from the spool directory after they print If you want to delete a file before it prints mark the file and then delete it with the key 1 Select the file using the keys A blinking arrow indicates the current file 2 Press to mark the file A checkmark displays next to marked files 3 Press to delete the file 4 Choose whether to delete the marked or unmarked files or press to cancel 5 Press once to return to the Files co
244. as form name FCB name and copies display on the Print Spool screen Others fields are maintained and used only internally by the software BARR RJE 505 E Spool Header To view the entire header for a file use the view header feature from the Print Spool screen This spool header example shows all possible fields PRINTER FORMNAME CHECKS LPF 042 PLPF 042 LPI 6 CONTROL 00 LOCNAME JOBNAME jobname COPIES 00000001 PRIORITY 5 STATE READY CLASS 1Y FCBLOAD FCBNAME fcbname UCS 12345678 00000FB5HDP 0D6C101 CARRIAGE CONTROL STOPS 1 00000FB50000004B END OF PRINTER FORM The spool header begins with the word PRINTER and ends with the text END OF PRINTER FORM followed by a form feed FF character Most field values are preceded by an identifier and an equal sign For example FORMNAME is a field identifier and CHECKS is the field value Spool headers for some files might not contain all the fields shown in the example because you might not be using features that cause the fields to be set Values underlined in the example indicate fields that BARR RJE maintains internally Note If you write programs to generate the Barr spool header be aware that the format of the header is subject to change without notice If you update your version of BARR RJE and the spool header format has changed you will have to change your programs To obtain the current format of the spool header assign PR1 FILE e
245. asks on printer 1 S PUN CLASS A starts CLASS A tasks on the punch device CA D c lt x 488 A 3 VSE POWER Remote Commands Data Translation gt ASCII and EBCDIC Standards Computers use a coding system to define the correspondence between the graphic symbols we see on paper and on screen and the hexadecimal codes manipulated in the computer Graphics include letters numbers punctuation and other symbols The PC and the mainframe each use a different coding system to represent these symbols The PC uses the ASCII American Standard Code for Information Interchange coding system ASCII codes are defined in the American Standard Code for Information Interchange publication ANSI X3 4 1986 from the American National Standards Institute Inc The mainframe uses the EBCDIC Extended Binary Coded Decimal Interchange Code coding system EBCDIC codes are defined in the IBM publication System 370 Reference Summary GX20 1850 Both the ASCII and EBCDIC standards include control codes that do not have a graphic representation These codes are used for control functions by printers and communication protocols In the coding standards the control codes are represented symbolically by two and three character abbreviations For example the control code for End of Transmission is represented as EOT When data is transferred between the mainframe computer and the remote PC it must be t
246. at do not require data lines sent on the reader to have the same length use the default value of 1 Some host systems require all reader lines to be a fixed length such as 80 characters If your host system has such a requirement specify the required minimum Valid values are 1 to 254 Maximum reader line length Specify the maximum length of data lines that will be sent on the reader MVS JES2 allows a maximum reader line length of 254 characters but some mainframe programs cannot accept lines longer than 80 characters If you are sending print files to another SNA RJE remote unit set this value to 132 so that all 132 columns of your print file are sent If you are using the BARR TRAN program you must use 80 as the maximum value ob oo im kzi i gt an Interpret characters 89 8A 8C 8D 9A and FF as ASCII 09 OA OC OD 1A and 7F Choose how the ASCII control characters 89 HT 8A LF 8C VT 8D CR 9A SUB and FF DEL are interpreted when you send files from the PC to the host computer Normally ASCII control charac ters are used to delimit ASCII records and are removed before each data record is converted from ASCII to EBCDIC and sent to the host computer Yes Default Ignore the hexadecimal 80 parity bit so that the ASCII control characters are treated as follows 89 09 8A 0A 8C 0C 8D 0D 9A 1A and FF 7F The ASCII control characters are removed before ASCII to EBCDIC conver
247. at 50 bytes each the FAT would require about 73 KB of XMS Use the Memory allocated for buffers and Extended memory allocated for buffers options to adjust the amount of extended memory the Barr software uses For more information about these memory options see section 18 6 Trace and Memory Options BARR RJE 143 External FAT File Example To learn more about creating an external FAT review these sample entries The example file below is for a FAT file that uses Filename Formname as the file match criteria 2 Filename Jobname Formname FCBname State Class Prty Copies Dispos payroll y checks Hold 1 1 1 2 inventory x j Hold 2 2 3 S tax K 1040 k T 5 tax n 1040a n r m 2 tax L 1040ez i T 2 w 2 appl i 8x11 A A 5 100 supplies i bar132 r B 3 a account new bar132 A s A 4 o travel expense 4 i 5 i Retain salesrpt ytd bar132 A y i 5 acct invoice r A default default default default Notice how the fields are aligned in columns below the column headers and how commas delimit fields or serve as place holders for blank fields These features are discussed in the guidelines that follow Guidelines for External FAT File Entries Follow these guidelines when you create or modify the FAT file Entry Types The external FAT file requires three types of entries m A header line first line Entry lines lines 2 n A default entry line last
248. ate Time CHECKS cK501 1 0 1 1998 1 24 97 10 35 PRICES Hold LABELS 2 3 2 4840 1 24 97 10 44 TAX1040 1040 1 5 1 5180 1 24 97 10 35 INVOICES INV99 2 5 8 3262 1 24 97 10 36 Select printer using t and press Enter Escape to exit Spooling paused 2 Select a printer by using the f Q keys A blinking arrow displays next to the current printer 412 24 2 Printers Command 3 If more than one printer is listed press to select a printer before you make any changes 4 Move among printer attributes by using Q or Tab 5 Make any changes to the printer attributes 6 Press to preserve the changes when you are done EZR Files Command Use the Files command to reach the Files menu From the Files menu you can change file attributes view a file view a spool header and delete files 1 Select F for the Files command The cursor moves to the first file in the list and the Files menu displays at the bottom of the screen Printer File State Form Class Prty Copies Size Lines Status LPT1 Ready STD 1 415 busy SUSPEND Ready STD 2 0 busy Date Time CHECKS CK501 A 0 al 1998 1 24 97 10 35 PRICES Hold LABELS 2 3 2 4840 1 24 97 10 44 TAX1040 1040 1 5 1 5180 1 24 97 10 35 INVOICES INV99 2 5 8 3262 1 24 97 10 36 Select file using t PgUp PgDn and press Enter or Tab to change V to view or H to view header Delete files by marking with Space and pressing Del Spooling paused Escape to exit
249. ating whether to retain or delete the file after it prints The letter D indicates the delete disposition and blank indicates the retain disposition This field shows the default disposition which is retain if you define a retain directory or delete if you do not define a retain directory unless you specify a disposition on the Print Spool screen in the File Attribute Table or with the Barr PRT utility P Page break indicator used internally by the software P indicates that the file has page breaks L indicates that the file does not have page breaks or has fewer than three page breaks within the first 600 lines This value affects how the software repositions the file for reprinting P tells BARR RJE to reposition the file to the top of the page where printing stopped L tells the software to reposition the file to one line above the stopping point 0 The PDIR identifier byte used internally by the software The byte value indicates whether the file contains a PDIR job separator BARR RJE sets this value from information obtained from the host SETUPHDR PDIR feature 0 The file contains a standard job or system message 1 The file contains a job separator The PDIR identifier byte is used by special applications When this byte is set to 1 BARR RJE splits a single host job containing multiple outputs into separate files and assigns a group code in the next header field D6C101 A six character group code the software generate
250. ault value of 2 will be used Token Ring Max In Specify the Max In value for the token ring logical link control LLC driver Max In is the maximum number of sequentially numbered frames that can be received before an acknowledgment BARR RJE 299 must be sent Valid values are 1 to 127 The default value is 1 If Max Out is set to 0 the default value of 1 will be used Performance Tuning If you increase the values for Token Ring Max Out and Token Ring Max In it can greatly reduce BARR RJE performance Adjust these options only if you are trying to mini mize the effects of network limitations Options for the Gateway Connection These options affect gateway communication links Number of Gateways in GatePool This option applies only if you use workstation software to connect to BARR GATEWAY and you use gateway pooling Specify the number of gateways in the gateway pool With gateway pooling two or more gateways share the workstation traffic Gateway pooling is discussed in the BARR GATEWAY manual Method of Gateway Pooling If you use gateway pooling select which method to use to obtain workstation to gateway connections a i A i o r Statistical With this method for connecting to pooled gateways the workstation has an equal probability of connecting to any of the gateways in the gateway pool The statistical method averages the number of users on each gateway Priority If there i
251. ause of unpredictable results To be safe XMS buffers free should not fall below 50 during maximum use Conversely if XMS buffers free is around 200 then XMS has been over allocated an o S a D S a E E o m N Page 2 X 25 Communications Statistics gt Press to advance to page 2 0 frames sent 0 frames overflowed buffer 0 frames received correctly 0 times no reply received in time 0 frames received with errors 0 frames aborted 0 undefined frames received 0 equipment errors page 2 next page reset Any key frames sent Number of SDLC frames sent to the host frames received correctly Number of SDLC frames received without errors 384 23 3 Communications Statistics frames received with errors Number of SDLC frames received with either CRC errors or frames shorter than two bytes indicated by an fA on the Communication Scope undefined frames received Frames received by BARR RJE that have an illegal SDLC control field or that are illegal in the current SDLC mode Indicated by an B on the Communication Scope frames overflowed buffer Number of SDLC frames whose size exceeded the Barr communi cations buffer Usually caused by an error in the frame or MAXDATA at the host exceeding MAXDATA in the BARR RJE configuration Indicated by a ii on the Communication Scope times no reply received in time Count of receive timeouts Whether Barr is a remote or host the program
252. ax Diagnostics Escape Selection tl7 EEX Statistics You can display statistics about PC conventional and extended memory buffers 1 To access the buffer statistics start at the Diagnostics menu Diagnostics Statistics Hardware Queries Link Diagnostics Escape Memory Dump Selection gt 2 Select Statistics an o S a D lt a E E o m N Product options and buffer statistics display Section 23 3 describes buffer statistics and other statistics 1 real buffers in use 126 real buffers free 0 XMS buffers in use BARR RJE 0 XMS buffers free Product Options RJE SDLC Any key 3 Press to return to the Diagnostics menu 374 23 1 Statistics EYJ Link Diagnostics 1 To access link diagnostics start at the Diagnostics menu Diagnostics Statistics Hardware Queries Link Diagnostics Escape Memory Dump Selection l gt 2 Select Link Diagnostics Diagnostics Communications Statistics VTAM Commands Line Trace NetView Bind Data Escape Selection l gt Select the type of link diagnostics to view Communications Statistics Provides statistics about communications activity since the BARR RJE program started These statistics help you evaluate the communications line s reliability and use See section 23 3 Line Trace Provides information for Barr Technical Support to d
253. b banner page always faces up on the fan fold paper stack 72 8 4 COM1 COM4 Devices Display count of lines or pages This option controls the count of lines or pages printed that appears on the Operation screen s Status Line and in the Print Spool screen s Units column For more information about the Status Line see section 20 2 For more information about the Print Spool screen see Chapter 24 Lines Default Display the number of lines printed This choice is typically used for line printers co i o S o D a 9 Ss es mr Ss a a Pages Display the number of pages printed This choice is typically used for laser printers Forms overlay directory Use the forms overlay feature to load electronic forms or to send additional printer control data or printer resources to the printer In this field enter the name of the directory where overlay files are stored Include the drive letter and full directory path Remember to create the actual directory with the DOS make directory md command If you do not intend to use this feature leave the directory name blank For more information about this feature see section 8 7 BARR RJE 73 n o 2 E a 3 G a a Fq oa EFJ NET1 NET12 Devices When you route print output to network printers you need to set the options described in this section The NET devices can use a device driver Novell print queue or TCP IP LPR
254. b nnnn Substitute the actual job number The I PR1 command interrupts the RJE printer so that job nnnn prints immediately if form name SYSOUT class and other selection criteria match oo im 53 a 7 i 3 a BARR RJE 243 Notes a E ras o L a Gr pas 244 13 5 Printer Forms Commands Sent to Host Chapter 14 Function Keys During BARR RJE operation you might need to send commands to the host computer to display and change the status of devices jobs and print and punch queues You can assign commands you use most frequently from the Barr software to the to function keys Then you can use the function keys from the Command to Host option on the Operation screen This chapter describes how to assign commands to the function keys Chapter 21 tells you how to use the function keys during BARR RJE operation oh A T 5 ix 5 A lt a 14 1 Selecting Function Keys You can assign commands to function keys from the Function Keys screen 1 Select Function Keys from the Installation Description menu Function Keys Each function key has two entries The first entry is a short phrase to describe the key The second entry gives the command sent to the host when the key is pressed Use the cursor to move within an entry Press Enter to move to the next function key F1 to F10 Shift F1 to F10 Ctrl F1 to F10 Alt F1 to F10
255. c cc lt a BARR RJE supports both modulo 8 and modulo 128 SDLC counts With modulo 8 the standard for other packages software can send only seven frames before it requires an acknowledgment Seven frames will not fill the 0 8 second satellite delay Modulo 128 removes this barrier because BARR RJE can exceed seven frames with modulo 128 Multiple Logical Units Multiple Sessions BARR RJE supports Multiple Logical Units which means the software sends and receives data concurrently on multiple devices For example you can issue commands from the console and send files from disk while you receive output to the printer Older communications protocols that support only a Single Logical Unit also supported by BARR RJE are less efficient when transferring data They do not allow you to send a job to the host while you receive print output Support for Dial Up or Dedicated Lines BARR RJE works equally well on a dial up switched or dedicated non switched line Transparent Transmission Transparent transmission ensures that all possible 8 bit codes transmit as data BARR RJE sends or receives a file of any type or format even if it contains control codes Unrestricted data coding is particularly useful for sending binary data floating point numbers packed decimal data unique specialized codes or machine language programs Other communication protocols restrict assigning certain 8 bit codes to the communication prot
256. can set up the software to receive print stream data automatically or to wait for you to issue a command to the host to initiate the data flow You can enable the RJE punch devices from the RJE Description screen as described in the Barr Host Definition Guide SPOOL1 SPOOL8 Spool printers route data from the print spool queue to destination devices for example SPOOL1 LPT1 First you need to direct files to the spool directory with an assignment like PR1 SPOOL You assign each spool printer criteria for routing files You can set up the print spool to automatically route files or wait for operator action You can enable the spool printers from the Print Spool Description screen See Chapters 9 and 24 for more information about print spool setup and operation 4 2 gt 7 i K LAN1 LAN4 The LAN connection devices route files from any DOS directory to the destination of your choice For example you can send files from a network directory to a PC printer by setting LAN1 LPT1 You can enable the LAN devices from the Devices and Printers menu as described in section 8 10 NW_QUE1 NW_QUE4 Data can be received to the PC from up to four Novell print queues You can direct print files to a PC attached printer for example NW_QUE1 LPT1 You can enable the Novell queue devices from the Devices and Printers menu as described in section 8 11 156 10 3 Source and Destination Devices Destinations
257. can use the spool File Attribute Table screen to assign a class Spool header from data Choose whether to extract a file s job name or form name from the file text and save it in the spool header This method is useful when other methods for obtaining the job name or form name are not available although it is not as reliable or flexible as the Barr OUTPUT statement If the data source is a host computer you usually can use options such as the JES2 HASP190 message or SETUPHDR PDIR record to obtain the job name or form name You can use this option to add a spool header to files received through any source device except COMMAND LOG or SPOOL1 to SPOOL8 if the Receive mode is ASCII 370 Channel Transparent or PostScript BARR RJE 189 Note The information to extract must occur at the same location in every file that will be received on the same source device No Default Neither job name nor form name information is extracted from the file Yes The form name or job name is extracted from a specified location in the received files and is stored in each file s spool header If a job name or form name is already in the spool file header for example from Edit Forms it will be replaced by the value obtained from the file text When you press on the Assign Devices Options screen you are prompted to select form name or job name and to specify the page line and column numbers where this information appears in t
258. cates when the software began recording statistics The time stamp appears after the label Statistics since on the bottom left side of the screen Statistics get refreshed when the program starts or when you use the reset command on the bottom of the screen to reset the statistics The second column contains the same type of information as the Statistics screen in section 23 1 The statistics provided depend on your connection type To navigate through the Communications Statistics screens use these keys N R or Any key 376 23 3 Communications Statistics SDLC Communications Statistics If you have an SDLC connection you can view a series of three screens Page 1 SDLC Communications Statistics 0 lines read 0 real buffers in use 0 lines printed or punched 126 real buffers free 0 SNA sessions active 0 XMS buffers in use 0 XMS buffers free Statistics since 16 08 02 page 1 next page reset Any key lines read Total number of data lines the Send command or LAN connections read and BARR RJE sends to a destination lines printed or punched Number of data lines received on the host print or punch stream to the Barr PC SNA sessions active Number of SNA RJE sessions currently active including printers punches readers console and commands from the keyboard real buffers in use Number of DOS communication buffers in use by BARR RJE real buffers free Number of DOS communication buf
259. ce Queue Options 0 00 eee eee eee ee eee 115 Queue Server Options 0 2 0 eee eee eee 116 Support for Forms and Multiple Copies 0 117 Chapter 9 Print Spool Description 2 0020005 119 9 1 How the Print Spool Works 00 0 eee eee ee eee 120 Files from One Source Write to Different Destinations 120 Attributes Control File Routing 0 0 2 0 0 2 0 cee eee eee 121 9 2 Checklist for Print Spool Setup 0 0000 122 9 3 Print Spool Description Screen 00 c eee ee ee eee 123 9 4 Advanced Spool Options 0 00 00 e ee eee 125 SPOOL ONON ae cece elie edd a ae AE E oboe Seabee ena 126 Reprint Options 00 cece eee eee eee eee 131 Retain Options 00 cece eee eee een eee 132 9 5 File Attribute Table FAT 0000 c eee eee 134 FAT Options Screen 0 0 eee eee ee eee 134 How the Table Works 0 0 0 0 ccc cee ee ce eee 137 PAT Crit nd sok eee ee ee ieee ei ee as 139 Maintain an Internal FAT 0 0 0 0 0 cee eee 141 Sample Internal Attribute Table 04 142 9 6 Maintain an External FAT File 0 00 00 143 Memory Requirements for Table Entries 4 143 External FAT File Example 0 0 00004 144 Guidelines for External FAT File Entries 0 144 9 7 Initial Spool Printer Settings
260. ce from which the enclosed Licensed Software may be used or accessed Multiple user is defined as more than one single user workstation Where networks of terminals are used each such terminal shall be counted as a separate single user workstation and must be licensed individually Licensed Software is the computer program licensed to Licensee regardless of the form in which Licensee may subsequently use it and regardless of any modification which Licensee may make to it The Licensed Software is distributed in machine readable form only and no source code is provided License means this agreement and the rights and obligations which it creates under the United States Copyright law and the laws of the several states and territories of the United States Licensee refers to the end user individual or company Product Hardware refers to any computer hardware manufactured sold or distributed by Barr Systems This is the entire agreement between Barr Systems and Licensee and it cannot and shall not be modified by purchase orders advertising or other representations of anyone All notices or other communications given under this agreement shall be in writing sent to the address presented above as the principal place of business of Barr Systems or such other addresses as Barr Systems may designate in writing Both parties acknowledge that they have read all the terms of this agreement understand it and are autho
261. ceived if the current directory is C BARR the file is written to that directory per the DOS convention Likewise if the current directory is the C root directory when a file arrives the file is written to the root directory When you try to locate the file you might not remember which directory was current when the file was received If you specify the full path in the file name field you eliminate confusion about the file location If you specify only the Ending of file name the file path depends on your selection Some choices for the name ending have no file path and others include a portion of the file path Each of these selections is described under Ending of file name If you use an ending name selection that does not include a file path files are written to the current DOS directory If you specify both parts of the file name the complete file name is the combination of the two parts Beginning of file name contains the drive letter and directory path and Ending of file name specifies the file name Some Ending of file name selections include a portion of the file path 162 10 5 Assigning a File as a Destination Ending of file name is __ If the Beginning of file name includes a directory name you must end the directory name with a backslash If you want to combine the beginning and ending portions into an eight character name omit the backslash If you include a file name in the Beginning of file name fiel
262. ces for more information about these options If you use the Barr PRT utility to copy LAN or PC files to the print spool you can specify file attributes before you copy the file See Chapter 25 Spool PRT Utility If you use the DOS copy command to copy files the files will not have a spool header but BARR RJE sets their class value to Z and preserves their original file names You can use the print spool s File Attribute Table FAT to preset or automatically override file attributes The values take effect as files are received from the host or copied to the print spool with the Barr PRT utility See section 9 5 for more information about the FAT While a file is waiting to print you can use commands on the Print Spool screen to change the attributes See Chapter 24 Print Spool Operation Table E 1 lists spool header field values you can change and indicates which options you can use to set their values See section E 4 for detailed descriptions of each field Japeay joods J BARR RJE 507 E Spool Header Table E 1 Methods for Setting File Attributes Method Spool Host Host File Attribute Description DOS PRT Print Output ieader PDIR FCB Copy Utility FAT Spool State from Edit HASP Screen ment Data Forms 190 Convert ASCII ASCII ASA carriage control from v y ASA to machine Carriage Control Stops Carriage control stops v
263. ces other than the host cannot be processed by PostScript receive mode For example files from PR1 can be converted to PostScript but PostScript receive mode does not apply to files input from LAN connections for example LAN1 If you want to print files from other sources in PostScript format the files must already be in PostScript format before they are received to the PC Note 2 You can edit the supplied overlay files or create additional overlay files from scratch by using the structure of the supplied files as a guide but Barr Technical Support analysts cannot assist you with any modifications 182 10 8 Receive Mode Fixed Length Receive Mode You can use Fixed length receive mode for special applications or situations that require data records to have a fixed length A common application for fixed length receive mode is receiving print files to a PC magnetic tape drive by assigning PRI TAPE Requires the BARR TAPE option which you must purchase separately The ASA carriage control character can be included as the first character of the fixed length record which allows the data to print correctly Fixed length records also are useful when you will process data at the PC Data used as input for application programs such as programs that generate a report or add the records to a database is often in fixed length format A 2 2 5 S o 7 When you select Fixed Length from the lis
264. ces you define Because the Barr software supports 12 NET devices up to 12 TCP connections are possible In the PC TCP software the default number of TCP connections is six This value is specified as tep connections 6 in the PCTCP INI file If you need more than six connections increase this value in the PCTCP INI file When you use the LPR option you must direct files to the LPR queue from the print spool Options for TCP IP LPR UNIX Print Queue If you select TCP IP LPR UNIX Print Queue as the network type for the NET device the following options display on the lower half of the screen 82 8 5 NETI NET12 Devices Network Printer Options NET1 network type TCP IP LPR UNIX Print Queue printer type Generic Use line printer daemon protocol Print server address Print queue Local Host name User ID Add form feed between jobs Yes Use name entered above for print queue name Print form header No Use print banners Yes Send Control file first No Control file Class field is not used Use native TCP IP port 9100 Enter character Use ___ protocol Select which protocol to use for the TCP IP NET device line printer daemon Default Files must be directed to a destination that uses the LPD protocol This choice requires that the file writes to the print spool before it is directed to the final destination for example SPOOL1 NET1 so BARR RJE can determine the file
265. ch line it checks for the keyword first and then its value You can specify the options in any order You can use mixed case type because PRT converts lowercase letters to uppercase N ol i gc y m J p lt Test your spool control files after you create them If a line does not contain a valid keyword or it contains an invalid value PRT ignores the line and displays an error message when you load the control file from the PRT screen or reference the control file in a PRT batch command Note Use CTR as the extension for all control file names to make the files easy to identify BARR RJE 44 EEE Operate the PRT Utility You can run the PRT utility in batch or interactive mode Batch mode allows you to spool files by typing a command at the DOS prompt a Interactive mode lets you view files change directories and select files to spool from the PRT screen With either method you can specify a control file to use and individual option values to override Note The PRT utility is too large to run interactively from a DOS session in BARR RJE but you can run it in the batch mode from the DOS session Batch Mode When you use PRT in batch mode you can specify control options from the DOS prompt You can use the default spool control file SPOOL CTR specify a different control file or override individual option values in a control file Batch Command Format To use PRT in batch mod
266. ch spool printer s state form and class State Current status of the spool printer Ready Spool printer is ready but no files can be selected because printer form and class do not match any file s form and class Printing Spool printer is ready and a file is printing Draining Spool printer is printing a file After the file prints the printer s state is set to Disabled If the file s copy count is greater than one and you set the printer state to Draining all the copies might not print After the current copy finishes printing the printer state is set to Disabled and the file state is set to Hold Disabled Spool printer is not ready No files will be selected Reprint When the printer is in the reprint state and a file is selected the Reprint screen shows the contents of the file beginning at the last line printed You can position the file by scrolling forward and backward or by specifying a page number From the Reprint screen you can use commands to restart printing at the new position or to disable the printer See section 24 7 for more information about reprinting files o i i 72 pan E Q N Form The name of the form mounted on the printer For a file to print the form name on the spool printer must match the file s form name When you specify a spool printer form you can use the DOS wildcard characters and A in the form name allows any char
267. command 427 Finnish Swedish character sets 277 First character of command sent to host 256 Fixed length receive mode 176 180 183 273 screen 183 Fixed length records 178 179 183 Florida Data printers 93 Flow control 63 67 hardware 64 software 65 FNA termination sequence 303 Fold printing on inside outside of 226 Form feed FF character 490 add between jobs 81 84 add to end of file 57 72 discard on serial port 70 ignore on printer 104 Form name 1Q40A message 284 Class as 191 ending of file name is 163 168 errors 360 See also File attributes form overlay file 288 from file 190 HASP190 163 285 521 JCL 169 218 Novell NetWare 117 OUTPUT statement 187 PDIR 516 route files by 79 SETUPHDR 283 spool control 126 spool display 126 spool header 509 translation table 79 85 87 work selection criteria 284 286 Form number Novell print queue 81 Form overlay 99 100 516 options 287 spool header 509 Form overlay directory COM device 73 LPT device 60 NET device 91 Form overlay files default file 289 embedding 100 extensions 287 289 naming 99 287 288 PostScript 100 182 printer control data in 60 91 printer resources in 60 91 reset string in 92 spool header 509 FORMIFCB name is used to control spool 126 Format printer output 102 280 Forms 22 215 513 applications requiring 513 assigning to printers 233 commands sent to host with 216 237 238 converting for laser printers 227 558
268. controllers Messoj9 communication link The physical connection and link protocol between the remote workstation and the host computer BARR RJE 535 communications line Any physical medium such as a wire or microwave beam used to transmit data communications protocol A specification of data and control mes sage formats and their meanings This specification is followed by both the sender and receiver in a communication link compaction In SNA communications the sender sends two bytes as one byte to increase data transmission throughput The receiver decompacts the data to the original two bytes compiler Programs that convert instructions written in high level languages to the machine language that the computer can interpret compression To increase throughput in data transmis sion the sender substitutes one character for a sequence of duplicate blanks and two characters for a sequence of non blank characters The receiver decom presses the data to its original state CON RJE console device See also console configuration 1 A specific combination of hardware that forms a system for PCs the term configuration describes characteristics such as the type of monitor adapter the number and description of printers the amount of memory and a description of serial ports 2 A specific combination of software options used to set up an application program console The device used to control
269. correlate the message with one of the product unique panels defined in NPDA The text message and qualifiers help the operator pass error codes telephone numbers and a message to the NetView operator EEE Memory Dump Barr Technical Support can often diagnose unusual communications prob lems by examining a copy of memory The copy of memory generated by BARR RJE is called a memory dump The memory dump is output to a file named DUMP Note You can change the name of the file to which the memory dump is output See step 1 below If Technical Support requests that you provide a memory dump follow these steps 398 23 8 Memory Dump 1 Assign the file to write to disk 2 Recreate the problem 3 Generate a memory dump If the problem Barr Technical Support is investigating involves receiving a file for example a file is not printing or is printing incorrectly you need to receive the file during the memory dump and write it to the PC disk so you can provide it to technical support Assign the device where the file will be received to a file destination The software automatically names the memory dump file DUMP Be sure to use a different file name for the file you are receiving From the Operation screen select Advanced o p From the Advanced menu select Assign Devices Select the source device on which the file will be received a Oo Select FILE as the destination Enter a fi
270. cted to a synchronous modem or Channel Service Unit Data Service Unit CSU DSU With the Barr SYNC adapter BARR RJE can communicate at up to T1 1 54 megabits per second Mbps or El 2 Mbps speeds 26 4 4 Communications Features 802 2 Network Version The BARR RJE 802 2 version connects to the mainframe via a 4 or 16 Mbps 802 2 LLC network The mainframe connection to the 802 2 network is through the Token Ring Interface Coupler TIC installed in the 3725 or 3745 front end processor FEP or 3174 controller The PC connection to the 802 2 network is through a token ring adapter A o gt pes wv a m pag oO 2 oO a Coax Version The BARR RJE Coax version uses a COAX adapter and coaxial cable to connect to a mainframe or cluster controller The COAX adapter supports DFT up to 5 sessions and 3299 up to 40 sessions protocols You can locally or remotely attach the controller to the host LAN Gateway Version A BARR RJE workstation can connect to the host through the Novell NetWare for SAA with the LUx interface and Microsoft SNA Server with the LUA interface LAN gateways or the Computerm and McData 6200 network gateways with the TCP IP protocol The workstation can connect to the gateway via any available LAN protocol The gateway provides logical units LUs for the workstation s RJE and 3270 sessions Simultaneous Sending and Receiving with DATMODE FULL BARR RJE operates at true f
271. d When it restarts logon BARR RJE drops the Data Terminal Ready DTR signal for 2 seconds which hangs up the telephone on an autoanswer modem EEJ File Transfer Features BARR RJE optimizes remote job entry and remote file transfer You can submit jobs from the PC to the host computer for processing or you can transfer files between the host computer and the PC disk drive BARR RJE also has enhanced file transfer capabilities as described in this section Local Area Network LAN Connection BARR RJE provides an excellent link from a LAN to a host computer You can automatically send files received from the host to the print server on the LAN Additionally users on the LAN can submit jobs to the mainframe by copying them into a directory on the LAN BARR RJE automatically checks the directory every 30 seconds and sends the files to the host After BARR RJE sends the files it deletes them or moves them to another directory 24 4 3 File Transfer Features Data Compression and Decompression Sequences of duplicate characters such as five blanks in a row four zeros at the end of a number or 40 blanks following a line of data exist in most files You do not need to send all these duplicate characters In a process called data compression BARR RJE sends one character for a sequence of duplicate blanks and two characters for a sequence of non blank characters A o gt pes wv a m pag oO 2 oO a
272. d it must be in the correct DOS format A file name extension is optional For more information about file extensions see File Name Extensions later in this section You have eight choices for assigning an ending file name _ A 2 5 S o D 2 Some choices affect the file path If you select formname jobname for the ending formname is included in the file path If you select jobname formname jobname is included in the path If you select jobname formname fcbname source filename or from file the file path is taken from Beginning of file name If the beginning portion of the file name is blank the file is written to the current DOS directory You can obtain the job name form name or FCB name from the JES2 HASP190 message SETUPHDR PDIR record or the Barr OUTPUT statement used in file option You can also obtain the job name or form name from the Barr Spool header from data option You might want to refer to other sections in this manual when you choose an Ending of file name For a description of the Barr spool header see Appendix E For information about the HASP190 message see Appendix F For a description of the Spool header from data option see section 10 9 jobname Default The job name stored in the spool header is used as the file name See Example 1 later in this section Note The job name from the HASP190 message might be unreliable because the host generates the message o
273. d JES2 476 JES3 484 Start communications at specified time 295 Start Device command VSE POWER 488 Start Print reprint command 427 Start Printer command 352 Starting BARR RJE console messages 326 during PC power on 322 from the DOS prompt 322 from the Installation Description screen 321 with a configuration file 322 Starting time AT modem 210 Dataphone 2224B 208 Startup delayed 208 210 295 301 sending files at 346 unattended 24 Startup Screen Notes 326 screen 259 State file 408 See also File attributes printer 406 See also Printer attributes spool header 510 Statistical gateway pooling 300 Statistics 374 802 2 380 Coax 382 communications 29 376 NetView 394 SDLC 377 time stamp 376 X 25 383 Status Line 29 64 323 354 DSR 0 297 flow control indicator 65 printer power off 59 units 60 73 XOFF 65 Status of printer 406 BARR RJE 569 STC printers 93 control codes 98 STK printers 31 Stop bits serial port 63 64 Stop task command VSE POWER 487 Strip leading nulls 69 Strip spool header option 410 Submit job to host See Send files to host Suspend device 153 158 form overlay file not found 290 LANI LAN4 111 NETI NET12 89 on error condition 158 SVC 291 SVF 520 Switched line 13 SYNC ISA adapter 263 264 Synchronous Data Link Control SDLC 16 Synchronous modem 3 Synchronous modem eliminator cable SME 298 458 System 36 10 17 T T send mode 343 T1 speed 14 26 Tabs compress data wit
274. d form overlays The options on this screen affect output files received on the source devices PR1 to PR7 gt To reach the Printer Control screen from the Tuning and Global Options menu select Printer Control 280 18 2 Printer Control Printer Control Use Barr FCBLOAD No FCBLOAD halve No Mount forms by Operation screen Disable form mount error messages No Disable channel stop not found error messages No Search for form overlay by FORMNAME Load form overlay file Always Use default overlay file if overlay not found No Default overlay file STD Suspend printing if overlay not found No Insert tabs to compress data on disk No Interleaved binary data No Maximum print position 255 3270 printer error time out in minutes 10 For 3270 printers reset FCB to default at end of file No XPAF special Vertical Channel Select sets print column to zero No Choice ob oo z gt im gz i 5 7 The options on this screen fall into these categories options for printer forms options for form overlays other print options and 3270 printer options Options for Printer Forms These options control the use of form information with print output Before you enable any of these options see Appendix F Form Information Sources for a comprehensive discussion of the methods you can use to obtain form information Appendix F will help you decide which fea
275. d the courier font from three other files First create a file named TAXFORM that contains the form text a file named LOGO that contains the company logo and a file named COURIER that contains the courier font code Next create an overlay file named TAXES that contains this text taxform logo courier When a job with the form name TAXES is ready to print the files containing the tax form the logo text and the courier font are loaded into the printer as an overlay Additionally the TAXFORM COURIER and LOGO files can be listed in other overlay files you create BARR RJE 101 Printer Control Data Printer control data is an optional feature for LPT COM and NET devices that you can use to control special functions of the printer For example you can set the page mode portrait or landscape page size lines per form lines per inch characters per inch and typeface On the Printer Control Data screen you enter codes for these printer functions as strings of characters in hexadecimal format Each control string is terminated by two bytes of hexadecimal zeros 00 00 When the software sends a file to the printer it sends the codes to the printer before the file Some strings can be sent at the end of the file n o 2 E a 3 G a a Fq oa This section tells you how to enter control codes on the Printer Control Data screen describes special control characters and gives several co
276. d to print on this printer what order they will print in and a few other details Because both Q and F are in the list in the example both class and form will be used as criteria to decide which print jobs will go to this printer You can remove a criterion from the list with the command T PR1 WS criteria The T section mentions using T PR1 WS F to remove forms from the work selection That means a job does not have to have the same form type as the printer to print that is all forms can print without the operator having to send a change form command to JES The next thing you might need to do is find out if output is waiting in the JES queue for this remote Unfortunately this is not always possible from the remote You can usually retrieve the necessary information by issuing the DF command The DF command is a reliable way to find out if output is waiting in JES for this remote It results in a list of the different forms and classes gt associated with any jobs waiting to print on this remote 5 o Z DF 15 54 29 z HASP621 OUT R R122 15 54 32 o HASP621 OUT R R122 F CTST C T x W NONE S HASP621 PRMODE LINE CLASS A 2 B 1 15 54 32 5 HASP621 OUT R R122 15 54 33 E HASP621 OUT R R122 F STD Cate T x W NONE HASP621 PRMODE LINE CLASS A 3 15 54 33 In the example six jobs are waiting three form CTST two class A and one class B and three form STD all three are clas
277. dapter channel attach Direct way to connect printers to S 370 mainframes character A single letter digit symbol space or punctuation mark character coded logon In SNA communications commands in character form entered by an end user These commands such as Logon and Logoff must be in the syntax defined in the user s unformatted system services definition table Also called unformatted logon clocking An electrical signal that occurs at a fixed rate that is used to control the speed of other circuits In synchronous communi cations both send and receive data have a clocking signal coaxial cable A heavily shielded and insulated carrier wire with high immunity to electrical interference and a low data error rate Coax can carry multiple streams of data on one line This is the same cable commonly used in the cable TV industry COM1 COM2 COM3 COM4 Asynchronous serial ports 1 2 3 and 4 on the PC command Something you instruct the computer to do such as run a program communication controller A communication control unit that manages line control and data transfer through a network Operations are controlled by one or more programs stored and executed in the unit Examples are the IBM 3705 3725 and 3745 Communication Controllers communication control unit A communications device that controls the transmission of data over lines in a network such as transmission control units and communication
278. dard RS232C for con necting data communication equipment DCE to data terminal equipment DTE including connecting terminals and com puters to modems Many computer periph eral devices also use this interface for connecting to the computers See also serial interface port RSCS Remote Spooling Communications Sub system of the IBM VM operating system RSCS is a remote job entry system that is compatible with BARR HASP RTS Request To Send signal S 370 IBM mainframe machine architecture See also channel attached SDLC Synchronous Data Link Control is a low level communications protocol for synchronous communications It is defined for both full duplex and half duplex oper ation SNA uses SDLC as its low level communications protocol sense code Data describing an I O error serial interface port Interface ports that send and receive data one bit at a time using the RS232 stan dard serial port input Files read from a serial port COM1 to COM4 and sent to the host These files can be printed sent to the host or routed on the LAN session 1 SNA communications between two logical units that start with a logon and end with a logoff 2 A BARR RJE screen dedicated to a particular activity SNA Systems Network Architecture A descrip tion of the IBM communications network a multilayered communications environ ment that usually uses SDLC as its lowest level communications protocol The de scription i
279. der The Novell form name and copy count will be stored in the corresponding fields of the Barr spool header and the Novell banner name will be stored as the job name oo i oO S o D a 9 Ss Z mr Ss a a To print multiple copies the file must be received to the print spool See Chapters 9 and 24 for more information about print spool setup and operation BARR RJE 117 Notes n o 2 E a 3 G a a Fq oa 118 8 11 NOVELL Queue Devices Chapter 9 Print Spool Description The Barr print spool makes it easy to route files and manage print jobs It operates like mainframe print spooling Print files are organized in a print queue a directory on the PC hard drive The print spool automatically sends the queued files to printers or other destinations according to file selection criteria you specify such as form name class and priority The print spool makes it easy to perform these tasks Receive files from a host computer or copy files from the network to the print spool Specify how many copies of a file you want to print The print spool provides the best way to print multiple copies of a file The software puts one copy of a file in the spool directory and the print spool sends the file to the printer the specified number of times a Automatically preset or change file attributes like form name and priority as files arrive in the spool direc
280. der messages indicating E printer activity are sent to the LOG destination This feature is useful if you want to charge printing costs to customers Files without a spool header and files that are empty zero lines printed are not logged Lu z The log information is recorded as each print job completes as shown in gt this example Ed Xn PRINTER LOG FOR PROE J jobname F f fcbname 15 33 55 198 LINES PRINTED AND 1 PAGES PRINTED 0 00 00 16 HH MM SS ss 198 LINES PAGE 74250 LINES MINUTE 375 PAGES MINUTE 7305 CHARACTERS 36 CHARACTERS LINE 0 CHARACTERS PAGE 45656 CHARACTERS SECOND The first line of the print message includes the destination device job name form name and time of day The following lines include the number of lines or pages printed duration of the print job expressed as hours minutes seconds number of lines per page number of lines or pages per minute total number of characters number of characters per line or page and number of characters per second The printer activity information displays in a fixed position on the message line and all numbers are right justified which makes it easier to search for this information with interactive editors or application programs 356 21 7 Console Messages NET Device Activity When output is routed to a NET device destination messages on the console indicate the source device and the actual print queue or dev
281. destination and press Enter File Screen When you select FILE as a destination the following screen displays Assign Devices Beginning of file name Ending of file name is jobname New File Log Enter character Use the fields on this screen to specify the file name and other file options BARR RJE 161 Beginning and Ending File Names A file name can consist of a beginning an ending or both You must specify at least one part of the name Choices for the name ending are described under Ending of file name Barr software follows the DOS file naming conventions See the examples for naming files at the end of this section If a DOS error occurs while naming the file BARR RJE attempts to resolve the error as described in File Name Error Handling also at the end of this section Beginning of file name Specify the name for the received file including the drive letter and full directory path 4 2 gt 7 i K If you specify only the Beginning of file name include the drive letter full directory path and file name If you do not include the path the file is written to the current DOS directory You need to include the complete file path in the file name to be certain where the received files are located For example suppose you omit the directory path from the Beginning of file name and you installed the software in the C BARR directory When a file is re
282. disk if the software encounters an error when it assigns a file name these messages might display on the console ERROR file name is blank File name changed to ERROR filename contains invalid DOS file name characters File name changed to newfilename ERROR invalid path for filename BARR RJE 359 i o a i Wu c gt s c co rr N You can disable these messages from the Tuning and Global Options Display and Disk Options screen as described in section 18 7 If you forget to specify a file name when you direct files to the print spool error messages like these display ERROR using device PR1 SPOOL Error on file C SPOOL DOS ERROR Path not found Section 10 7 explains how to specify file names for spool files If you forget to specify a file name when you direct files to disk error messages like these display ERROR using device PR1 FILE Error on file DOS ERROR Path not found Section 10 5 explains how to specify file names for disk files Form Name Errors If you set up the software to automatically mount user defined forms this message displays if a form is not defined SETUPHDR received but form TAX1997 not defined You have two choices for resolving this message Define the form as described in Chapter 13 and receive the file again If you are not using user defined forms set Disable form mount error messages to Yes on the Tuning
283. e Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PR2 gt C STUDY5 PU1 SUSPEND SPOOL1 LPT1 Continue Escape Receive mode Options Help With this assignment m If the file contains the text GRADES05 on line 2 columns to 8 then the combined file name is C STUDY5 GRADES05 001 The software automatically generates the file extension If you omit the backslash at the end of C STUDYS the name would be C STUDY5GR 001 The file name will be terminated by the ending column position or a blank character whichever comes first For example the text GRADES 05 will become GRADES BARR RJE 171 a If no text is found at the specified position the file is assigned the name ERROR and an error message displays on the PC console File Name Error Handling BARR RJE attempts to resolve errors with file names or path names When the software names files according to the Assign Devices Beginning of file name and Ending of file name options it substitutes an exclamation point for an invalid DOS file name character For example if the file name contains a forward slash xyz the software substitutes an exclamation point xyz If the file name begins with a period abe the software replaces the period with an exclamation point abe 4 2 gt 7 i K If the software encounters a path error it changes the Ending of file name to ERROR
284. e You can also attach peripheral devices such as a modem and printers If the PC is on a LAN you can access LAN directories and devices For more information about modems see section 2 3 For more information about RJE workstations and 3270 terminals see Chapter 3 RJE Devices RJE devices are the paths or streams over which you exchange data between the host computer and PC workstation The RJE workstation uses RJE devices for the following applications Sending programs and data files to the mainframe computer for processing Sending commands to the mainframe to control output flow and inquire about the status of other RJE devices Receiving job output from the mainframe to the PC Receiving job setup messages from the host The host programmer enters parameters at the host to allow the host computer and the PC workstation to communicate and to set up the RJE devices over which data messages and commands flow see Figure 2 1 10 2 2 RJE Workstations command to host COMMAND p aAA to host reader RD1 s da3uo9 ary Z console message CON from host printer PR1 from host punch PU1 Mainframe PC Figure 2 1 RJE devices allow the PC workstation and the host computer to exchange data and messages The requirements at your site determine which RJE devices to use Review the available devices below and then discuss your RJE needs with your host communications consultant Command
285. e new file location must have the same drive letter as the original file location For example move jobs payroll 001 lan1 payroll 001 n o 2 E a 3 G a a Fq oa The move command supports moving multiple files with the DOS wildcard characters and For example move jobs pay f lan1 a You can rename the file when you move it For example move f jobs payroll 001 lan1 checks 001 a If a file with the same name already exists in the destination directory the move command displays an error message It does not overwrite the file To overwrite a file with the same name use the d switch For example move d pathi file path2 For online help with the move command type move at the DOS prompt and press Enter LAN Connection Example This example shows how to use LAN connections to submit jobs to the mainframe from the local area network To route files to the host you will assign LAN1 RD1 on Assign Devices screen On the LAN1 Connection screen specify the options as follows 112 8 10 LANI LAN4 Devices LAN1 Connection Check Read directory for new files every 30 seconds Read directory F HOST Retain directory F HOSTSAVE Delete old Retain directory files No Retain files for 7 days Start JCL file F JCL START JOB End JCL file F JCL END JOB o i o S o D an 2 Ss ies m 3
286. e transmitting data faster than another device can receive the data Some printers use XON XOFF flow control some printers use hardware flow control and other printers use both A printer that uses hardware flow control uses a signal on an RS232 pin to show that it is ready to receive data The printer cable normally connects this signal to Clear To Send on the PC serial port The serial port interface is described in Appendix C cTs Default Test Clear To Send CTS before sending data DSR Test Data Set Ready DSR before sending data DSR amp CTS Test both Data Set Ready and Clear To Send before sending data The Status Line on the Operation screen indicates which of the signals is low If both signals are low DSR 0 is used DOS uses this flow control method 64 8 4 COM1 COM4 Devices XON XOFF flow control None Do not test CTS or DSR Use this choice for printers that do not use hardware flow control but use only XON XOFF flow control To determine whether you have selected the correct flow control option check the Status Line on the Operation screen When you set the printer offline the Status Line displays XOFF CTS 0 or DSR 0 When you set the printer online the Status Line displays normal For more information about the Status Line see section 20 2 i D S o 2 iJ Ss es mr Ss a a XON XOFF is a type of software flow control For a general discussion of flow control see the
287. e type the PRT command at the DOS prompt followed by the name of the file you want to spool and any control files or options you want to specify The format of the command is as follows prt myfile txt controlfile option value gt D e c a o a 7 wo N where a myfile txt is the file to add to the print spool controlfile is the control file to use If you do not specify a control file the default SPOOL CTR options are used Precede the control file with the character option is the control file option to override You can override as many control options as you like See Table 25 1 for a list of control options Only the first three characters of each keyword are required 442 25 3 Operate the PRT Utility Table 25 1 PRT Spool Control Options aan Maximum z Parameter Description Length Valid Values ASA_CC Convert ASA to machine 3 Yes No carriage control for ASCH files sent to S 370 printers CLASS Class to be assigned to file A Z 1 9 CONTROL Printer control string to be sent 2 Hexadecimal with file code COPIES Number of copies to print 4 1 9999 DESTNAME File name to use in spool 12 directory FCBNAME FCB name associated with file 8 FORMNAME Form name associated with the 8 file HEADERS Use file separator header page to 3 Yes No identify printed files JOBNAME Job name associated with file 8 LOCDISP Disp
288. e ASCII to EBCDIC and EBCDIC to ASCII translation tables for use with native language character sets When you use code pages other than standard ASCII and EBCDIC ones you must change the tables to translate the native language characters correctly IBM has defined various code pages that are variations of either ASCII or EBCDIC and contain extra symbols for particular languages or national ities The extra symbols are different for each language so each language requires a different code page Follow these steps to install the correct code page on your PC and to select the corresponding character set in the Barr software a i A i o r 1 Determine which EBCDIC code page your host application uses The choices are the same as those listed on the screen in step 4 2 Determine which ASCII code page to use on your PC Barr software supports code pages 437 US and 850 multilingual Code page 850 contains the symbols from all other non US ASCII code pages and was designed to replace the other non US code pages Code page 437 is the default for most PCs If your host code page is English US and no other PC applications require multilingual support choose 437 Otherwise choose code page 850 3 Install the selected ASCII code page on your PC using DOS version 3 3 or later See the discussion about Code Page Switching in your DOS manual For the US English character set use ASCII code pages 437 US or
289. e Escape Receive mode Options Help 2 Select Receive mode from the menu line Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 gt SPOOL PU1 SUSPEND SPOOL1 LPT1 ASCII N ASCII lines Variable ASCII lines Transfer files Transparent Binary DOS obsolete Fixed length 370 Channel PostScript l gt 3 Select a receive mode from the list of choices on the lower portion of the screen For example select ASCII An asterisk displays next to the destination device when you select a receive mode other than ASCII Most PC applications use ASCII format BARR RJE 177 Receive Mode Choices You can select from the following receive modes ASCII Default ASCII is the format used on the PC and is required for files printed on an ASCII printer If the original file is in EBCDIC format it is converted to ASCII format with the ASCII carriage control codes carriage return CR line feed LF and form feed FF The EBCDIC format is used by host computers See Appendix B for more information about these formats Packed decimal data Before you transfer data that includes packed decimal fields you should use a separate program to unpack the data Packed decimal data gets corrupted during translation from EBCDIC to ASCII with any file transfer program 4 2 gt 7 i K Binary Data remains in EBCDIC format the format used by the host computer
290. e a au Uk We cane Rak GNA a a N e A eg 19 3 5 Host Parameters aler ana A eE Sher aria ee eee aes 19 Chapter 4 BARR RJE Features 200 0c e eee e eee eee 21 4 1 Printer Support Features 000 21 4 2 Ease of Operation Features 0 0 0 0 0 2 0c e ee eee 22 4 3 File Transfer Features 00 0 cc A cee eee 24 4 4 Communications Features 0 cc eee eee eee eee eee 26 4 5 Diasnostic Features iio hack Hoke Siw inte Sieh td eg a a A 29 4 6 Optional Features 00 0 eee eee eee 30 Chapter 5 Software Screen Conventions 0 05 33 5 1 Screen Documentation 0 0 00 c ee eee eee eee 33 3 2 Scheen Cues TETE arn ai auah che Cee A Va ek ona eee eS 34 D3 STEEN KEYS nore bees Rega Savin Gita telat Diectamasd E tate oe toes 35 Chapter 6 Software Installation asuasanannnnnnnnnnnnn 37 6 1 Installation Steps 0 0 ee ee ee 37 6 2 Conti gure the PCr ra ra hii ds dete Wine elie kt 37 Changes to CONFIG SYS gnusa einni eee eee 38 Changes to AUTOEXEC BAT 000002 39 6 3 Install the Barr Software Files 0 00 0 cee eee ee eee 39 Software File Descriptions 0 00 00 c ee eee 39 Software Installation Steps 00 0 eee eee eee 40 Store the Disk as a Backup 00 00 02 cece eee eee 44 Access the Installed Files 0 0 0 cece eee eee eee eee ee 44 Return to the Installation Description
291. e command sequences for autodial autoanswer and manual connections Autodial Sequence Drop DTR Pause 2 seconds Send Reset to Command Mode string Pause 2 seconds Send Set Factory Defaults string Pause 2 seconds Send First Initialization string Pause 2 seconds Send Second Initialization string Pause 2 seconds Raise DTR Pause 1 10 second Send Autodial amp Autoanswer Model string Pause 2 seconds Send Autodial amp Autoanswer Mode2 string Pause 2 seconds Send Dial Prep string followed by phone number ss N a D Ej 5 a 2 o 5 N Autoanswer Sequence Drop DTR Pause 2 seconds Send Reset to Command Mode string Pause 2 seconds Send Set Factory Defaults string Pause 2 seconds Send First Initialization string Pause 2 seconds Send Second Initialization string Pause 2 seconds BARR RJE 213 Raise DTR Pause 1 10 second Send Autodial amp Autoanswer Model string Pause 2 seconds Send Autodial amp Autoanswer Mode2 string Manual Connection Sequence Drop DTR Pause 2 seconds Send Reset to Command Mode string Pause 2 seconds Send Set Factory Defaults string Pause 2 seconds Send First Initialization string Pause 2 seconds Send Second Initialization string Pause 2 seconds Send Manual Answer Mode string Raise DTR a Fad i E a E v g i i N gt 214 12 4 AT Modem Options Printer Forms Business applications typically invo
292. e following example shows you an efficient way to transfer files The example sends a file from Remote 20 to Remote 99 1 Create a file named RMT99 with the following information 454 26 2 Transferring Files from PC to PC RMT99 JOB account programmer TYPRUN COPY MSGCLASS B ROUTE PUNCH RMT99 The account and programmer parameters are your account number and name The JES2 TYPRUN COPY feature takes an input job and immediately copies it to the output queue MSGCLASS B indicates that the JCL output will be marked as PUNCH output The ROUTE statement specifies that the PUNCH output will be sent to RMT99 The word PUNCH starts in column 10 and RMT99 starts in column 16 From the BARR RJE Operation screen 2 Select Send Files 3 Type RMT99 f ilename TB EJ Packaging BARR RUJE in an Application You can package BARR RJE in an application program so users do not see BARR RJE operation details for example in data entry environments Packaging BARR RJE This process occurs when you package BARR RJE in an application program 1 Your data entry program collects data into files 2 The application program calls BARR RJE and specifies files to send to the mainframe 3 BARR RJE uses a modem to autodial the mainframe N z 7 D 2 2 gt kZ E a 4 BARR RJE sends files to the mainframe and receives printouts on the PC 5 BARR RJE disconnects and exits to the program that called it
293. e is changed Setting the state to HOLD gives the operator time to make prepar ations such as changing the paper on the printer before the file prints Printer control BARR RJE printer control string selector This hexadecimal field is an index to the Printer Control Data table for the destination device Each LPT COM or NET device has a separate table as discussed in section 8 8 The control string associated with this index code is sent with the file to the printer Control strings are commonly used to set printer lines per inch and fonts N ol i gc m J p lt Formname An eight character form name This often indicates pre printed forms paper that must be loaded in the printer Note Does not reference a form in the Edit Forms table Fcebname An eight character FCB name BARR RJE 437 Note Does not reference a form in the Edit Forms table Jobname An eight character job name Lines per inch Number of print lines per inch usually 6 or 8 Lines per form Number of actual lines on the printer form Includes top and bottom margins For example if the length of the printer form is 11 inches and line spacing is set to 6 lines per inch the number of lines per form is 66 Print lines per form Number of lines used for printing the form Excludes top and bottom margins Print lines per form should be less than or equal to Lines per form For example if Lines per form is 6
294. e page on printer 1 F PR1 5 forward spaces the output five pages on printer 1 F PR2 D forward spaces the output to the end of the dataset on printer 2 F PU1 6 forward spaces the output six cards on punch 1 H Hold The H command puts a job under the operator s jurisdiction on hold If a job is queued and on hold the job remains queued and the system takes no action on the job If the job is active the job finishes its current activity and then re queues If a job is awaiting print punch or execution it remains in that state until it is released If a job is being read it finishes being read and then enters the execution queue on hold A job currently executing finishes execution and enters the print queue on hold CA D c lt x Format The operator can specify a job name or number with the H command H jobname where jobname is the name of the job to place on hold 470 A 1 JES2 Remote Commands H Jnnnn where nnnn can be a single job number to place that job on hold or a range of job numbers to place a series of jobs on hold Examples H MYJOB places the job named MYJOB on hold H J357 places job 357 on hold H J240 500 places all jobs ranging from 240 to 500 on hold H J250 0630 places only jobs 250 and 630 on hold I Interrupt The I command interrupts the job currently printing or punching and queues the remaining portion for later pri
295. e printer control index From the Edit Forms menu create a form named COMPRESS Edit Forms Name COMPRESS Lines per form 66 Print lines per form 66 Lines per inch 6 Printer control 01 Enter character gt Set the value for Printer control to 01 2 Define the command sequence Follow these steps to enter the printer control data for the selected LPT COM or NET device a Enter a hexadecimal 12 at the first position in the table The string at the beginning of the table is sent before every job b Skip the next two pairs of zeros 00 00 to separate the control strings This separator is required c Begin the next string with the printer control index 01 230 13 3 Using Printer Control Data with Forms d Enter the compress control code OF e End the control string with two pairs of zeros 00 00 This terminator is required Your control data sequence will look like this HEX 12 00 00 01 OF 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 When a file requiring the Barr form COMPRESS is ready to print the soft ware searches the Printer Control Data table for the string that begins with the specified index in this example 01 First the software sends the beginning code 12 to the printer Then it sends the form information to the printer followed by the control string OF associated with
296. e printers or destinations of your choice In this example two spool printers have been defined SPOOL1 and SPOOL2 The SPOOL1 device is already defined to LPT1 Follow these steps to assign SPOOL2 to LPT2 1 Select Continue to return the cursor to the assignment area Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PR2 SPOOL PU1 SUSPEND SPOOL1 LPT1 SPOOL2 SUSPEND Select SOURCE DESTINATION Escape Selection tJ 2 Select SPOOL2 Assign Devices DESTINATION FILE SCREEN NUL SUSPEND LPT1 LPT2 COMMAND RD1 SPOOL Selection l gt 3 Select LPT2 BARR RJE 175 Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PR2 SPOOL PU1 SUSPEND SPOOL1 LPT1 SPOOL2 gt LPT2 Continue Escape Receive mode Options Help 4 When you press the screen reflects the new assignment 5 When you finish making assignments press to return to the Installa tion Description screen Note Do not set a receive mode on the source devices SPOOL1 to SPOOL8 unless you have the BARR TAPE option and are assigning the destination TAPE g 2 gt i i oe 10 8 Receive Mode Receive modes change the format of the files received to the Barr PC from the data source Specifically they affect data translation and carriage control Your choice for receive mode depends on how the data will be
297. e result is different depending on whether you have a dial connection or a dedicated line as described below Dial connections Maintain the telephone connection after the software exits so you can re establish the host connection without having to redial the telephone Use this feature if you want to exit BARR RJE run another program and then run BARR RJE again without redialing Dedicated line using a Synchronous Modem Eliminator SME cable The host computer tries to maintain the connec tion after BARR RJE exits The mainframe operator will not need to reactivate the line before you restart the Barr software Full duplex multi drop line Specify whether the PC is a full duplex station on a multidrop shared communications line This option adjusts the way polling is performed on the communications line to prevent the BARR RJE station from monopolizing the line a i A i o r No Default The PC is not a full duplex station on a multidrop line Yes The PC is a full duplex station on a multidrop line Adjust the polling method Line speed when using SME cable If you use a synchronous modem eliminator SME cable select the communications line speed See your Barr communications adapter manual for more information about SME cables 298 18 4 Modem and Line Control Options for the 802 2 Link These options affect the 802 2 communication link over token ring or ethernet networks Usuall
298. e section 8 7 Also see the Printer Requirements section in the Barr PRINT370 manual Xerox Channel attached Laser Printers Forms are stored in Xerox printers and commands embedded in the data cause the printer to load the form Xerox forms are different than standard forms created at the host or in the BARR RJE Edit Forms table See the Barr PRINT370 manual for more information IFJ Using SETUPHDR with Edit Forms Using SETUPHDR with Barr forms provides the most reliable form information and is the most common method When the SETUPHDR feature is enabled at the host computer the host sends a Peripheral Data Information Record PDIR with each print file to the remote workstation The PDIR contains setup information typically used for printing Because the PDIR does not include format information you must define a Barr form to supply these values BARR RJE 515 nm T i 3 3 i 3 f o 5 i E i E L L PDIR Information The PDIR supplies the following values Form name FCB name Job name Copies UCS train name The PDIR does not supply file format information lines per inch lines per form and carriage control stops If you use the SETUPHDR feature you must define Barr forms that contain the format settings The software uses the PDIR form name or PDIR FCB name to determine which Barr form to use Figure F 1 shows how information from the
299. e spool directory and update the list of files on the Print Spool screen This option affects only those files copied into the spool directory from DOS or the LAN Files received from the host computer display immediately upon arrival The default check interval is 300 seconds Performance Tuning Do not use a short interval such as 5 seconds because frequent checks reduce software performance Log operations to LOG device Specify whether messages are written to the console log file to help you track print spool activity To use this feature you must specify LOG FILE on the Assign Devices screen For more information about the console log see section 10 6 No Default Spool activity messages do not appear in the log file Yes Messages are written to the console log file when spool files are printed reprinted deleted retained or restored See section 21 7 for examples 130 9 4 Advanced Spool Options Reprint Options These advanced spool options control the spool reprint feature For more information about the spool reprint feature see section 24 7 Include spool header only once during reprint When you reprint spool files choose whether the spool header information is sent to the printer only once for a given file or with each reprint operation for that file The selection you make depends on your printer s requirements Yes Default When you use the reprint operation the spool header information is included onl
300. e table applies to all NET devices with a network type of Novell Print Queue or TCP IP LPR UNIX Print Queue FCB FORM to Print Queue Translation Table oo D S o a 2 Ss gt me Ss o a Name File Server Print Queue Name File Server Print Queue Name File Server Print Queue Name File Server Print Queue Name File Server Print Queue Name File Server Print Queue Bytes remaining in table 1167 Press Escape to exit Enter character How the Table Works When it routes a file to a print queue the software checks for the file s FCB name or form name in the translation table entries You determine which value the software checks by your selection for Use _ for print queue name on the Network Printer Options screen If a match is found in the table the file is routed to the corresponding file server and print queue If a match is not found the software performs the action described under Error Handling later in this section BARR RJE 87 Guidelines for Making Translation Table Entries The FCB FORM to Print Queue Translation Table has a fixed size in bytes and holds a variable number of entries depending on the number of bytes per entry If the table entries are short the table can hold a larger number of entries As you add entries to the translation table the number of bytes available for additional e
301. e under warranty for a period of one year following the date the Licensed Software and the Product Hardware were mailed or otherwise made available to Licensee Support for the Licensed Software and the Product Hardware beyond the 2 2 53 Z 53 i 3 2 i 5 BARR RJE 327 initial one year warranty period may be obtained by Licensee through the purchase of an annual Licensed Software and Product Hardware Maintenance Agreement from Barr Systems Barr Systems warrants that the Licensed Software and the Product Hardware will perform substantially in accordance with the published specification statement documentation and authorized advertising Provided Barr Systems is notified of significant errors during the warranty period Barr Systems shall at its option 1 Provide telephone support phone 800 BARR SYS or 352 491 3100 to correct significant and demonstrable Licensed Software program or documentation errors within a reasonable period of time or 2 Repair or replace the Product Hardware within a reasonable period of time if it should prove defective or 3 Provide or authorize a refund of the purchase price of the Licensed Software or the Product Hardware Transfer or Reproduction The Licensee shall not sell assign sublicense copy or otherwise reproduce in whole or in part or transfer any copies of the Licensed Software to another person subsidiary parent company or other company without the
302. ect to the gateway through a LAN or a dial up connection with an asynchronous modem BARR RJE supports these LAN protocols Novell IPX NetBIOS 802 2 LLC token ring and TCP IP Modems You can transmit data between the PC and host computer through telephone lines The word modem is derived from the terms modulate and demodulate When the PC workstation sends data the modem converts modulates digital signals to the analog signals the telephone system uses When the PC receives data the modem restores demodulates the signal to digital form See your Barr modem hardware manual for more information about synchronous and asynchronous communication modem standards and external and internal modems 2 3 Communication Links and Modems Host Environment oo x i 77 2 m 5 i 3 o 5 E3 SNA is the all encompassing framework for communicating in the IBM mainframe environment SNA is an evolving communications architecture that constantly adapts to the changing needs of business research and government This chapter describes the SNA network from the end user s viewpoint As shown in Figure 3 1 the SNA communications network connects user workstations in the network with mainframe applications Mainframe Applications SNA Network 0 ESE SDLC X 25 802 2 or Coax BARR eee RJE Figure 3 1 IBM mainframes communicate through SNA networks EA Mainframe to Workstation Communication
303. ed files as needed The Restore screen displays without a delay Use this selection to improve Restore screen performance when on average more than 300 files reside in the retain directory For more information about displaying attributes for individual files see View File Attributes in section 24 6 Use current date and time when Retaining files Choose whether to use the file s original date and time or to change to the current date and time when files are copied to the retain directory 132 9 4 Advanced Spool Options Yes Default Change to the current date and time when a file is copied to the retain directory This choice helps you determine how long a file has been stored in the retain directory It is useful if you plan to automatically purge files from the retain directory at regular intervals because the file s original date does not necessarily indicate how long the file has been in the retain directory Files received from the host or submitted with the PRT utility are assigned the current PC date and time when they arrive in the spool directory but they might not be retained the same day they arrive Files copied from the PC or the network keep their original dates in the spool directory but their dates might already exceed the retain period No Use the file s original date and time when a file is copied to the retain directory This choice helps you determine the age of the original file Delete old Reta
304. ee ee 177 Receive Mode Choices 0 0 0 0 cece e eee eee ee 178 Fixed Length Receive Mode 00000 e eee ee eee 183 10 9 Options for Assign Devices 0 000000 0c ee eee 185 Restrictions for Assigning Options 000 186 Options that Affect the Spool Header 0 0 186 Other Options eng devs sere isle tn T araa aaa ad E din oa esnand ass 192 10 10 Assigning Several Sources to One Destination 193 10 11 Plot Output Assignment 0 0 00 196 Chapter 11 Monitor and Adapter 00 c eee e eee eee 199 11 1 Monitor and Adapter Screen 000000 000000 199 11 2 Monitor and Adapter Options 0 0 0008 200 11 3 Screen Size Options 0 0 eee eee eee ee eee 201 11 4 Screen Border Option 0 0 0 0 eee eee eee 202 Chapter 12 Modem Type and Dialing Instructions 203 12 1 Modem Selections 0 0 0 a e eee eee 203 BARR RJE ix 12 2 12 3 12 4 Chapter 13 13 1 13 2 13 3 13 4 13 5 Chapter 14 14 1 14 2 14 3 14 4 Modem Connection Screen 0 00 c eee cee eee eee 205 Dataphone 2224B Modem Options 2 0200 ee 207 AT Modem Options 0 0 0 0 ereere renere 208 Modem Options zin terrines is steel gain a oa Baw wetness Seeks 208 Command Strings 0 0 eee A eee ee eee 211 Connection Command Sequences
305. een _ A 2 5 S o D 7 LOG The console log is a copy of the messages written to the PC console CON SCREEN If you want a record of processed files you can direct copies of messages to a file by assigning LOG CONSOLE LOG If you assign LOG SCREEN the log data will be deleted to prevent duplicate messages from displaying on the screen You can browse the log from a DOS session while it is being updated by the software See section 21 7 for more information about the types of messages you can log The log device is disabled by default but you cannot remove it from the Assign Devices screen You can enable it by setting LOG FILE and assigning a file name as described in section 10 6 PR1 PR7 Print files from the host RJE system are received on print streams RJE print files usually contain carriage control information Typically you direct them to a PC printer as in PR1 SPOOL or PR1 LPT1 You can set up the software to receive print stream data automatically or to wait for you to issue a command to the host to initiate the data flow You can enable the RJE printer devices from the RJE Description screen as described in the Barr Host Definition Guide PU1 PU4 Punch files from the host RJE system are received on punch streams Punch files usually contain data that will be processed at the PC Typically you will direct punch data to a PC file such as BARR RJE 155 PU1 TAXDATA You
306. eive plot output you must select Binary receive mode to prevent the plot files from being converted from EBCDIC format into ASCIL The files need to remain in the host computer format to print correctly When you use Binary receive mode BARR RJE ignores any carriage control information in the received files 4 2 gt 7 i K Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PU1 COM1 SPOOL1 LPT1 Continue Escape Receive mode Options Help 1 From the Assign Devices screen select PU1 and assign it to the destina tion COM1 2 Select Receive mode from the menu line at the bottom of the screen Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 LPT1 PU1 COM1 ASCII N ASCII lines Variable ASCII lines Transfer files Transparent Binary DOS obsolete Fixed length 370 Channel Postscript t lon 3 Select Binary and press Enter The Assign Devices screen reflects the new assignment Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PU1 COM1 SPOOLI LPT1 Continue Escape Receive mode Options Help 196 10 11 Plot Output Assignment The asterisk after the destination COM1 indicates that a receive mode other than ASCII has been assigned _ A 2 2 5 i S o 7 BARR RJE 197 Notes 4
307. elect Exit and Save Changes Please enter choice Continue loading software Exit You can configure the software from the Installation Description menu a To reach the Installation Description menu press C to continue Or press E to exit to the DOS prompt If you are installing a software update and choose Continue you are prompted to enter the name of the configuration file Please enter configuration drive path file b To load the configuration file from another version of the software type the configuration file path and file name If you do not want to include a configuration file now leave the field blank The following screen displays when the Installation Description is loaded BARR RJE 43 S T S PA w p 72 o Installation Description Barr Systems Inc 800 BARR SYS P O Box 147015 352 491 3100 Gainesville FL 32614 7015 Dear Customer I trust this program meets with your expectations Our company depends on your support to develop quality software therefore please observe our copyrights We welcome your suggestions and will give immediate assistance to problems with our product Sincerely Tony Barr Programmer Copyright C 1983 1997 Barr Systems Inc Any key c Follow the instructions in Chapters 7 through 18 to configure the software When you finish configuring the software select Exit a
308. elect Printer Forms Commands Sent to Host The command entry screen displays Printer Forms Commands Sent to Host Commands sent when form mounted P PRn E PRn Commands sent when printer started T PRn F ffffffff S PRn Commands sent after HASP190 or 1Q40A message S PRn Enter character You can specify three types of command strings on this screen The commands you enter must be in the format required by your RJE system The default commands displayed on this screen are for JES2 Commands sent when form mounted When the form is mounted with the manual Mount Forms command the commands on the first line are sent to the host computer Usual ly you enter commands on this line to drain or pause the RJE print stream This stops file activity so additional commands can be issued Commands sent when printer started After the form is mounted with the manual Mount Forms command the commands on the second line are sent to the host computer to start the RJE print stream Usually you enter commands on this line to tell the host computer to release jobs that require the mounted form Commands sent after HASP190 or 1Q40A message Commands entered on the third line are sent to the host computer after BARR RJE receives a JES2 HASP190 message or VSE POWER 1Q40A message These messages are used for automatic forms mounting The third command line lets you issue the appropriate start printer command in re
309. elect the source device on which the file will be received d Select FILE as the destination e Enter a filename for example DATA f Return to the Advanced menu by pressing Esc Note You only need to change the destination to FILE if the file you are creating will be used for diagnostics and you are not currently writing to a file N oo o Ej 3 9 K Ss an o an a Set up the Barr software to generate a line trace b Check that the Line trace buffer size option is large enough to record the trace See section 18 6 Tuning and Global Options Trace and Memory Options for more information about this option c From the Advanced menu select Diagnostics d From the Diagnostics menu select Link Diagnostics e From the Diagnostics screen select Line Trace The following screen displays BARR RJE 387 Trace is Off Format is Full Filename is DUMP Choice f Press to change Trace to on g If necessary change other line trace options as described below Trace Choose whether to enable the trace Off Default On Trace data is written to the file DUMP Format Select the trace format Short Only the first 59 bytes of the information frame are written to disk Full Default All bytes of the information frame are written to disk h Change the filename if necessary The default is DUMP i After you select Line Trace options pre
310. election 405 log operations 130 messages 355 multiple copies 119 193 519 operating after disconnect 302 See also Print spool screen size 199 201 sort criteria 128 sorting files 417 Spool control files edit 441 maintain 434 options 443 Spool control options 434 436 Spool destination devices assign 122 SPOOL device 153 159 164 165 assigning destination to 174 Spool File Attribute Table See File Attribute Table Spool file attributes allow operator to modify 129 override values 134 write changes to file 134 Spool files backspacing 423 group code 511 Spool header 187 415 505 console log 356 example 506 form information 283 format 505 format information 281 from Novell job 117 group code 412 511 Novell NetWare values 117 options affecting 186 overlay name 288 page break indicator 425 print 85 PRT 433 strip 192 viewing 415 writing to file 191 505 Spool header from data option 163 189 Spool printers 121 156 164 disabling 410 draining 410 number of 123 route files from 175 Spool reprint See Reprint Spool Retain directory 124 date and time for files 133 delete old files 133 duplicate file names 167 retain period 133 sort criteria 129 spool header display 132 Spool Retain disposition 141 Spool source devices assign 122 SPOOL CTR file 433 434 436 SPOOL1 SPOOL8 devices 153 156 164 Spooling PC or LAN files 433 Standard STD form 284 285 290 example 221 Start bit serial port 64 Start comman
311. emote Job Entry RJE concepts to help you understand BARR RJE s role in PC to mainframe communication EAR Remote Job Entry Mainframe computers support remote workstations that send files to and receive reports from the mainframe RJE system RJE is the term used to describe this process of sending files and printing reports at high speeds An RJE workstation operator has complete console control of the job flow between the workstation and mainframe The RJE workstation is called a remote because it usually is located some distance from the host computer The workstation connects to the host through a modem or local area network LAN When you send jobs from the remote workstation to the host computer the process is called remote job entry BARR RJE is compatible with these mainframe RJE systems a MVS JES2 a MVS JES3 a VSE POWER a VM RSCS a VS1 RES BARR RJE EFJ RJE Workstations A PC equipped with software and either a Barr synchronous com munications adapter or an IBM Token Ring adapter replaces expensive RJE workstations such as IBM 3777 System 36 or AS 400 In fact the PC s higher throughput and easy to master user interface uniformly out perform the older technology 2 RJE Concepts The Barr software and hardware allow the PC to emulate an RJE workstation or 3270 terminal The 3270 emulation requires Barr RJE 3270 software An RJE workstation consists of a PC a communications adapter and softwar
312. en When you select this command PRT prompts you to supply the directory name and file name template File Display a file on the screen You can select a file from the list or enter a file name Leave the PRT screen temporarily to go to the DOS shell To return to PRT type exit at the DOS prompt N ol i gc m a pa lt Exit the PRT program When you select Quit the PRT version number displays in the lower right corner Press to exit the PRT program or press to cancel Example Command Sequence In the simplest case you just need to use the first two PRT commands to load a control file and submit a file to the spool This example command sequence shows how you might use the first four PRT commands to submit a file BARR RJE 445 Display a File Directory Use the File Directory command to specify which directory to list on the PRT screen The current directory name displays at the top of the screen Directory of C BARR File Size Date Time File Size Date Time BARR CFG 14120 03 26 97 10 39 TEST CTR 120 03 26 97 14 51 SPOOLP EXE 177917 03 27 97 13 21 SPOOLP4 EXE 180205 03 27 97 10 43 PRT EXE 157290 03 27 97 10 02 START JOB 19 03 26 97 10 36 END JOB 18 03 26 97 10 36 JOB 15 03 26 97 10 37 SPOOL EXE 156413 03 26 97 11 23 SPOOL CTR 120 03 26 97 14 51 SCAP ASC 765 03 28 97 08 31 SCREEN CUT 2492 03 28 97 09 14 FD 328 03 28 97 11 06 MYLIST 15 03 28 97 11 48 OVERRIDE CTR 120 03 26 97 14 51
313. en no other alternatives are available you can use Spool header from data with the Class option to assign a one character form name To do this set Class to a unique value and set Spool header from data to Yes with a page number of 0 The one character Class value is used as the form name and displays in the form name column on the Print Spool screen You can use the one character form name as criteria for printing the files or to load a form overlay file containing printer control data Several other header options are available so use this special feature only as a last resort _ A 2 5 S o 7 Write spool header to file When you receive data to a destination of FILE you can choose whether or not to include the Barr spool header in the file The spool header contains information used for printing Normally the header is included only in files received to the print spool This option is valid only for the destination FILE and can be set independently for each source device Write spool header to file does not apply to files received to the print spool because spool headers are automatically included when the destination is SPOOL This option is not valid for files received on serial ports COM1 to COM4 This option is useful in these situations When forms are enabled at the host but you want to omit the spool header for the destination FILE To enable or disable the spool header whe
314. end ASCII format files to the host by including the send command in a DOS file The embedded send files command is the double pound sign BARR RJE treats the text specified after the as if you entered it with the Send Files command from the Operation screen The included files also can have the instructions There is no limit for nesting the statements 344 21 4 Send Files Note 1 If the file contains characters you want BARR RJE to treat as data and not as the send files command use the 1 send mode after the file name Note 2 Include the full file directory path in the embedded command Example 1 Default Send Mode This example shows how you can send a JCL file and a data file by using the embedded send files command and the ASCII A default send mode JOBNAME JOB 1010 333 777 TBARR EXEC PGM IEBGENER SYSOUT DD SYSOUT A SYSUT2 DD SYSOUT A SYSUT1 DD H C DATA FILE1 1 In the JCL file enter the embedded send files command 2 Use the Send Files command on the Operation screen to send the JCL file BARR RJE interprets the embedded send command and sends the FILE1 file in the C DATA directory with the JCL As BARR RJE sends the JCL and DATA files it converts them from ASCII to EBCDIC Example 2 Binary Send Mode You can include a send mode after the file name just like you can when you send files from the Operation screen JOBNAME JOB
315. ending printer control data strings in addition to a string referenced by a printer form the control strings are sent to the printer in the following order Starting printer control string Printer form information Printer control string associated with the printer form Print job GN OR Sor Ending printer control string For more information about starting and ending printer control strings see section 8 8 Printer Control Data BARR RJE 229 Printer Control Data Examples The following examples illustrate how you can use printer control data with forms created in the Barr software See section 8 8 Printer Control Data for more information about how to enter control sequences into the table See your printer manual for a list of the control codes your printer uses Example 1 Compressed Print This example shows how to use a form named COMPRESS with printer control data to print characters in a compressed format The Printer control index value 01 is used to link the form to a command sequence beginning with 01 in the Printer Control Data table This example requires you to make entries on both the Edit Forms and Printer Control Data screens a E ras o p a Gr _ The printer codes shown in this example are for an IBM 80 CPS matrix printer which compresses print when the hexadecimal code 0F is sent to the printer Hexadecimal 12 sets the printer back to standard mode 1 Specify th
316. ent destination After you enable a LAN device you must define the options on the LAN Connection screen Then users can copy files into the designated directory with the DOS copy command or Barr move utility You also can specify whether files are to be deleted or saved to another directory after they are sent BARR RJE 107 LAN Device Menu gt From the Devices and Printers menu select a LAN device For example select LAN1 A list of options displays Devices and Printers LAN1 deleted Use this device Delete this device n o 2 a 3 n a 2 gt i Options Escape Selection gt The same choices display for each LAN device Use this device Enable the LAN device You must select this option to enable the device The selected LAN device displays as a source device on the Assign Devices screen Before you can use the LAN device you also must select Options and define a LAN connections directory Delete this device Default Disable the LAN device and remove it from the Assign Devices screen The status deleted displays next to the device name at the top of the screen The Assign Devices screen is easier to read if you disable devices you do not intend to use Options To use the LAN device you must specify additional options including the LAN connections directory See LAN Connection Options below Escape Select Escape or press the key
317. ept any input off Printer is offline or the power is off error Printer is in an error state paper Printer is out of paper or the cable is not connected Parallel printer status is more precisely defined by the electrical signals on the printer cable Table 20 1 lists electrical signals that correspond to the printer status 324 20 2 Monitoring the Connection Process Table 20 1 Printer Status Electrical Signals Electrical Signals Status PE Displayed Busy Bust Paper Error Pin 11 Pin 15 Pin 12 off OV OV OV off OV OV 5V normal OV 5V OV normal OV 5V 5V error 5V OV OV paper 5V OV 5V busy 5V 5V OV busy 5V 5V 5V S Serial Printer Status Fields J COM1 0 CTS 0 Fa m N COM1 Serial printer for which information is displayed that is COM1 5 COM2 COM3 or COM4 5 0 Line in the file the printer is currently printing CTS 0 Current status of the printer as follows normal Printer is functional CTS 0 Clear To Send signal is off No data will be sent to this device DSR 0 Data Set Ready signal is off No data will be sent to this device BARR RJE 325 XOFF XOFF flow control character has been received No data will be sent to this device Receipt of XON flow control character will clear this condition Console The console appears on lines 3 through 20 of the Operation screen The console displays dial up call progress the mainfra
318. er choices After you make a selection your choice displays on the Devices and Printers menu next to the device name On the sample screen above the printer type is Generic Miscellaneous printer options Several options affect printer performance For a description of these options see Miscellaneous Printer Options for LPT Devices later in this section For a description of other options that affect printing see section 18 2 Tuning and Global Options Printer Control BARR RJE 55 Printer control data Printer control data allows you to send control codes to the printer such as commands to set the lines per form and lines per inch or commands to reset the printer You can use printer control data alone or with Barr printer forms Section 8 8 tells you how to set up this feature Escape The Escape option appears twice on the screen Select Escape or press the key to return to the Devices and Printers menu n o 2 E a 3 G a a Fq oa Miscellaneous Printer Options for LPT Devices You can use several printer options with LPT devices to simplify print data processing or to solve printing problems gt From the Devices and Printers menu for the selected LPT device select Miscellaneous printer options Miscellaneous Printer Options LPT1 printer type D P I Printer performance optimized Yes including expanding tabs not printing blank lines and generating VFU commands
319. erial port COM1 input from LAN LAN1 output to printer LPT1 COM1 NET1 output to LAN FILE zi a ic o PC devices 2 and the LAN g Figure 10 2 You can send data from the PC to other PC devices or to the network and receive data to the PC from the network or from PC devices ETF Assignment Screen gt To reach the device assignment screen from the Installation Description menu select Assign Devices The screen below shows the initial device assignments in the software Any additional devices you define are reflected on your screen Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PU1 SUSPEND SPOOL1 LPT1 Select SOURCE DESTINATION Escape Selection tJ7 Source and destination devices display in pairs separated by an arrow The arrow shows the direction of the data flow For example in the pair SEND1 RD1 SEND1 is the source device and RD1 is its destination BARR RJE 151 Device Assignment To assign devices select a source device with the cursor Notice that the arrow blinks when the cursor rests under it When you press Enter a list of destination devices displays See section 10 3 for a description of the available source and destination devices Menu Selections After you make an assignment the Assign Devices screen is updated to reflect your selection and a menu line displays at the bottom of the screen
320. ers free should not fall below 50 during maximum use Conversely if XMS buffers free is around 200 then XMS has been over allocated N oo o Ej 3 o K Ss an o na X 25 Communications Statistics If you have an X 25 connection you will view a series of four screens Page 1 X 25 Communications Statistics 0 lines read 0 real buffers in use 0 lines printed or punched 150 real buffers free 0 SNA sessions active 0 XMS buffers in use 0 XMS buffers free page 1 next page reset Any key lines read Total number of data lines read by the Send command or LAN connections and sent to a destination by BARR RJE BARR RJE 383 lines printed or punched Number of data lines received on the host print or punch stream to the Barr PC SNA sessions active Number of SNA RJE sessions currently active including printers punches readers console and commands from the keyboard real buffers in use Number of DOS communication buffers in use by BARR RJE real buffers free Number of DOS communication buffers available to BARR RJE Do not let this value reach 0 or the results might be unpredictable To be safe real buffers free should not fall below 20 during maximum use XMS buffers in use Number of extended memory communication buffers in use by BARR RJE XMS buffers free Number of extended memory communication buffers available to BARR RJE Do not let this value reach 0 bec
321. erts SCS carriage control used by the RJE system to ASA carriage control If the host file has no carriage control the RJE system adds SCS carriage control If the host file has machine or ASA carriage control the RJE system converts it to SCS Character set Specify which character set to use for the data EBCDIC Data remains in EBCDIC format and is padded or truncated to fit the specified record length Control characters included within transparent strings TRN are preserved Control char acters not included in transparent strings are converted to carriage control or are discarded including CR LF FF IRS NL VT TRN SEL HT BS and CSP These characters are documented in Appendix B Data received in this format usually is written to magnetic tape or is processed by an application program Usually this type of data will not be printed ASCII Data is converted from EBCDIC to ASCII and records are padded or truncated to fit the specified record length The ASCII data does not contain carriage return and line feed pairs CR LF to indicate record boundaries or form feeds FF to indicate page boundaries Usually this type of data will not be printed 184 10 8 Receive Mode ASCII with CR LF Data is converted from EBCDIC to ASCII and records are pad ded or truncated to fit the specified record length The ASCH data includes carriage return and line feed pairs CR LF to indicate record boundaries but does not include
322. es KEJ LPT1 LPT3 Devices When you attach devices to the PC parallel ports you need to set the options described in this section After you configure your printer you can print a test file to verify that the configuration is correct See Appendix D Printer Test for instructions to perform this test LPT Device Menu gt From the Devices and Printers menu select an LPT device For example select LPT1 A list of options displays 54 8 3 LPTI LPT3 Devices Devices and Printers LPT1 printer type Generic Use this device Delete this device Choose printer type Escape Miscellaneous printer options Printer control data Escape oo i oO S o an 2 Ss s me 3 e a Selection tl The same choices display for each LPT device Use this device Enable the LPT device You must select this option to enable the device before you can use it The selected LPT device displays as a destination device on the Assign Devices screen LPT1 is enabled by default Delete this device Disable the LPT device and remove it from the Assign Devices screen The status deleted displays next to the device name at the top of the screen The Assign Devices screen is easier to read if you disable devices you do not intend to use Choose printer type You must choose the type of printer to use When you select this option a list of printers displays Section 8 6 describes the print
323. es You can change a file s state form disposition class priority and copies attributes from the Print Spool screen BARR RJE writes your changes to the spool header so your changes are preserved if you exit the software before your files print Typically you do not need to change any file attributes or you only need to change the copies attribute Changing the Form Attribute When you change the form attribute you are changing only one part of a file s form information Modifying the form attribute only changes the form name in the spool header Form information included at the time the BARR RJE 407 file is received consists of more than just the form name For example a form usually also includes lines per form and lines per inch settings In most cases if a file is received with an incorrect form it must be received again with the correct form to ensure that all the form informa tion is correct However there are two cases when changing the form attribute on the Print Spool screen is helpful When you use form overlay files the form name is used to trigger the overlay file If you need only an overlay file and not a form definition changing the form attribute has the desired results it sends the correct overlay file If form information is stored in the printer instead of the spool header and the form attribute in the file is used to trigger the form name in the printer changing the form attribute on the P
324. es 40 Output media PSERVIC X 01106000F90040 card reader and punch files 80 Output media PSERVIC X 01106000F90080 document files 21 00 FM header flags PSERVIC X 01106000F9008000 80 22 00 Reserved PSERVIC X 01106000F9 00800000 23 01 SCS input PSERVIC X 01106000F9 0080000001 includes TRN IRS 24 00 Reserved PSERVIC X 01106000F9 008000000100 25 40 Input media PSERVIC X 01106000F900800000010040 card format Barr software does not support exchange media BARR RJE 393 N oo o Ej 3 o K Ss an o an an S a D S a E E oO m N EJ VTAM Commands A common use of VTAM commands is to send the IBM test command to verify that VTAM is operating VTAM returns a message with the 48 most common characters You can send VTAM commands from any active LU 1 Start at the Link Diagnostics Diagnostics menu Diagnostics Communications Statistics VTAM Commands Line Trace NetView Bind Data Escape Selection t gt 2 Select VTAM Commands Command sent to SSCP from LU 0 IBMTEST 1 Enter number 3 Enter the LU number from which the command should be sent 4 Enter the command to be sent The default is IBMTEST 1 which is the IBM test command to verify that VTAM is operating NetView NetView is a licensed mainframe program that collects information about SNA network operation and performance It resides o
325. es per form and lines per inch settings as well as carriage control stops It tells the printer how to print the job in the correct format The form name indicates the type of paper to use in the printer Many jobs use standard paper but jobs such as checks or invoices require special forms paper A form name is usually required for print spooling Sources for Form Information Several different host computer features can supply form information The host options available to you depend on which features your host opera ting system supports The two primary host features are FCBLOAD which supplies format information and SETUPHDR which provides the form name Because IBM mainframes do not support both SETUPHDR BARR RJE 513 nm T i 3 3 i 3 f z i 5 and FCBLOAD on a single remote workstation you can enable only one of these host features You can also define form information in the Barr software Barr forms include a form name and format information Common Ways to Obtain Form Information You can obtain form information solely from the host solely from Barr forms or from a combination of host information and Barr forms The three most common methods for obtaining form information are outlined below The first two methods provide a way to automatically receive form information while the last method requires action by the PC operator SETUPHDR with Edit Forms Use Edit Forms in the Barr soft
326. es per inch values in the file before it arrives at the PC Or the Barr software can provide these values using the printer forms feature If the lines per form LPF and lines per inch LPI values are not provided the software uses the default values LPF 66 and LPI 6 If your printer is not listed in Table 8 1 determine whether one of the printers in the table provides the control codes used by your printer If the BARR RJE 95 n o 2 E a 3 G a a Fq oa correct codes are listed select the corresponding printer from the Choose Printer Type screen If the codes for your printer are not listed use the Generic selection and enable another Barr feature printer control data forms overlay or printer forms to provide the control codes Table 8 1 Printer Control Codes Printer Model Setting Control Codes ANSI LPI 6 ESC 1 z American National 1B 5B 31 7A Standards Institute LPI 8 Esc 2 z DEC DATA South 1B 5B 32 7A LPF nn ESC m t 1B 5B nn 74 nn 1 to 99 as ASCII digits C Itoh LPI 6 ESC CR CI300 C1600 1B 3F 21 22 OD LPI 8 ESC CR 1B 3F 21 23 OD LPF nn ESC SP x CR 1B 3F 20 x OD x nn 6 LPI 31 as binary byte nn 1 to 99 DAVFU Dataproducts LPI 6 User manually sets switch Data Printer LPI 8 User manually sets switch LPF nn 1D 41 40 r 41 40 1E r nn 1 repetitions of 40 40 VEU Supper nn 1 to 126 D P LPI 6 m SOH Da
327. es the job named DATA D gt wo Examples z wo S A DATA S 3 2 3 s an A J245 releases job 245 A J2 70 releases all jobs with numbers ranging from 2 to 70 A J245 0747 releases only jobs 245 and 747 BARR RJE 461 B Backspace The B command backspaces the job currently printing or punching Operators can use this command when printer or punch malfunctions produce distorted output They can reprint or repunch part of the output without restarting the entire job The B command has two operands The first operand identifies the printer or punch to backspace The second operand gives the number of pages or lines to reprint or repunch or it tells the device to backspace to the beginning of the current dataset When the operator backspaces printed output the B command counts page ejects that is skips to channel 1 not physical pages If no pages eject B backspaces to the beginning of the dataset Format Enter the B command as follows B dev y where dev is a printer PR1 or punch PU1 and y is the number of cards to repunch the number of pages to reprint or the letter D which indicates a backspace to the beginning of the dataset The number of cards or pages can range from 1 to 9999 If you do not specify a number the system backspaces the printer one page or one line Examples B PR1 backspaces printer 1 one page to the last page eject CA
328. escription menu whenever the Barr software is not running At the DOS prompt type the program name followed by the letter i barrsnar i Bypass the Automated Installation Process You should use the automated INSTALL program when you install a new Barr product or an update The automated process is easy to use and performs some important steps However if you are experienced with DOS commands you can bypass the automated INSTALL process with these steps 1 Copy the compressed software files from the disk to the desired direc tories with DOS commands 2 Type the name of each compressed file at the DOS prompt to expand it within its corresponding directory 3 Delete the original compressed files from the hard disk after you expand them BARR RJE 45 Notes S S T S pA 72 o 46 6 3 Install the Barr Software Files Installation Description Use the Installation Description screens to configure the software You need to set up software features and enable the software to communicate with the PC adapter and host computer You can save the installation options to the program or to a configuration file Your settings are used each time you start the software Any time the software is not operating you can change the software N gt a pa o a i 5 wo nan ix J options by starting the Installation Description from the DOS prompt Am
329. ese guidelines when you set the sort criteria Use the 2 key to move among the sort fields 128 9 4 Advanced Spool Options Sort For each sort field use the key on the keypad to select from the list of file attributes to sort by Prty Class File Size Form Date or Time m Set any unused sort fields to blank By default files are sorted by the highest priority Prty gt and o oldest date and time Date lt and Time lt In the sort criteria a y greater than sign gt indicates ascending sort order and a less than sign lt indicates descending sort order Possible sort criteria are as 3 follows F Value Sorts by Sort Order 2 Prty gt Priority highest to lowest Prty lt Priority lowest to highest 7 Class File class lowest to highest File File name alphanumerically Size gt File size largest to smallest Size lt File size smallest to largest Form Form name alphanumerically Date lt Date oldest to newest Time lt Time oldest to newest Date gt Date newest to oldest Time gt Time newest to oldest blank Field not used Field not used retain files by ___ oe ee You can specify up to four fields for sorting files on the spool Restore screen which is used to manage retained spool files The default is to sort by the newest date and time Date gt and Time gt Sort criteria choices for this option are the same as those for the Sort spool files by option See Chapter 24 Print Sp
330. est Hard Disk Conflict Test and Register Test for Phase 1 These instructions display for Phase 2 Loopback Test of SYNC Adapter The second phase of loopback tests all adapter functions For this phase you will need the TEST plug which comes attached to the BARR communication cable Unplug the cable from the SYNC adapter and plug the TEST plug into the SYNC adapter Press ENTER to begin the test You may skip this part of the test by changing the option below to NO Perform TEST plug test Yes Choice 4 Install the loopback test plug and press to start the test The software performs adapter Signal and Send Receive tests for Phase 2 When Phase 2 completes these instructions display for Phase 3 BARR RJE 267 _ N 53 o 3 J o 2 an paa z N 5 amp c a 5 paa S a Loopback Test of SYNC Adapter The third phase of loopback tests the cable and external modem If your modem does not have analog loopback mode this test will not function correctly Unplug the TEST plug from the SYNC adapter and plug the BARR communication cable back in Make sure the other end is connected to the modem Set your modem to analog loopback mode In this mode all data sent to the modem is returned to the adapter Press ENTER to begin the test You may skip this part of the test by changing the option below to NO
331. etermine which printer to route each file to and in which order to print them A file is routed to a printer when the file s attributes match the attributes of one of the spool printers You can control how files are routed by changing printer and file attributes on the Print Spool screen After a file prints BARR RJE removes it from the print spool directory and the Print Spool screen You can keep a backup copy of spool files by defining a retain directory BARR RJE moves files from the spool directory to the retain directory after they print You can reprint or delete the retained files from the Restore screen 403 N A m 3 N g o So 3 e S i ES Managing Print Spooling The Print Spool screen lets you control printing This screen lists the files in the print spool displays information about those files and provides information about printers assigned to the spool gt To reach the Print Spool screen press Ctrl Alt and P from any screen Printer File State Form Class Prty Copies Size Units Status 1 LPT1 TAX1040 Printing 1040 1 5 1 284 415 busy LPT2 Ready LABELS 2 0 busy Date Time CHECKS CK501 1 0 1 1998 1 24 97 10 35 PRICES Hold LABELS 2 3 2 4840 1 24 97 10 44 2 LPT1 TAX1040 Printing 1040 1 5 1 5180 1 24 97 10 35 INVOICES INV99 2 5 8 3262 1 24 97 10 36 Printers Sort t PgUp Help 3 Files Check Spool PgDn Escape Restore The Print Spool screen
332. events The Communication Scope has a function similar to a communications line monitor You can resolve most low level communications problems by examining the Communication Scope The Status Line on the second line displays the status of printers disks and serial ports BARR RJE 29 Loopback Diagnostic Program The loopback testing program is an important tool you can use to verify correct operation of the Barr synchronous communications adapter the modem cable and the modem an gt 2 ras wi gt es gt cc cc lt EYJ Optional Features You can extend BARR RJE with optional add on products for specialized applications These products are integrated with BARR RJE operation for your convenience Several product options are outlined below Contact Barr Systems for a copy of the latest product catalog which contains a complete listing of Barr SNA products product options and prices RJE 3270 You can extend BARR RJE to include up to four 3270 sessions Both 3270 terminal emulation and printer emulation are supported You can use the RJE 3270 option for simultaneous RJE file transfer RJE printing 3270 interactive communication and 3270 printing You can also order BARR 3270 as a standalone product Tape Support The BARR TAPE software enhancement supports file transfer using industry standard nine track 6250 bpi tape drives or 18 track 3480 3490 and 3490E or 36 track 3490
333. ew data scrolls onto it This selection slows the rate that data scrolls across the screen Yes The screen scrolls fast without blinking Using this selection with some IBM color adapters will cause snow to display on the screen Display error messages when invalid DOS file name characters are replaced Choose whether the software will display an error message if it replaces an invalid file name character with an exclamation point 1 Yes Default When software replaces an invalid file name charac ter it displays a message on the console See section 21 7 for examples of messages that might display No When the software replaces an invalid file name character it does not display a message Use VERIFY OFF to improve disk performance This option can enhance disk performance by as much as 60 percent and is especially useful with communications line speeds of 56 Kbps or greater ob oo im Ezi i gt an Yes Default The DOS verify function is disabled while BARR RJE is running When the software writes data to the PC disk it does not read back the data to verify that it was written correctly Disk performance increases when you disable the verify function No The DOS verify function is enabled for disk write operations When BARR RJE writes to the PC disk it immediately reads back the data to verify it Commit files to disk every _ seconds At the specified interval update the time stamp for f
334. f EE LPI 8 Start LPF with ED instead of EE LPF nn EE 41 40 r 1E r nn 1 repetitions of 40 40 nn 1 to 143 98 8 6 Choose Printer Type Forms Overlay You can use the Barr forms overlay feature to print electronic forms or to send printer control data or printer resources to the printer These applica tions are described below When BARR RJE is ready to print a file it searches the forms overlay directory for a specific overlay file If BARR RJE finds the overlay file it sends the overlay file to the printer before the print file BARR RJE can send another overlay file at the end of the print file co oO S o an 2 Ss s m Ss a a To set up the forms overlay feature you must specify the name of the directory where you will store the overlay files for each device For the LPT COM or NET devices the overlay directory name is on the Miscellaneous Printer Options screen If you have the PRINT370 option the overlay directory name is on the Printer Options screen for the S 370 channel attached printer You also must set the forms overlay options on the Tuning and Global Options Printer Control screen as described in section 18 2 Naming the Overlay File All overlay files must be named with the same convention You can name them for the form name FCB name job name or UCS name Specify the naming convention with the Search for form overlay by option on the Tuning and Global Op
335. ferent file servers at a time If you use the the Barr NOVELL Queues option the software logs into one file server as a print server This type of connection is different from the user connection made by the NET devices to access Novell print queues The software will not log out of the print server connection during program operation n o 2 E a 3 G a a Fq oa Because Novell does not allow a PC to log into the same file server as both a user and a print server the NET devices cannot access the same server used by the Novell queues NW_QUEn Of the eight possible server connections the number available for use by BARR RJE depends on how many server connections are used for other purposes The PC can log into file servers when you power it on before the Barr software starts These server connections are used to access network drives and cannot be logged out by the Barr software The Barr LAN connections feature can use these connections If you use the Barr NET devices to access Novell print queues the software will log into and out of file servers as needed Novell Banner Pages BARR RJE supports banner pages at the beginning of jobs and form feeds at the end of jobs received on Novell NetWare queues The Novell client software controls whether or not banner pages and form feeds are generated Banner pages include the user name queue name file name and other information that helps identify job
336. fers available to BARR RJE Do not let this value reach 0 or the results might be unpredictable To be safe real buffers free should not fall below 20 during maximum use N oo o Ej 3 D K Ss an o na XMS buffers in use Number of extended memory communication buffers in use by BARR RJE XMS buffers free Number of extended memory communication buffers available to BARR RJE Do not let this value reach 0 or the results might be unpredictable To be safe XMS buffers free should not fall below 50 during maximum use Conversely if XMS buffers free is around 200 XMS has been over allocated BARR RJE 377 Page 2 SDLC Communications Statistics gt Press to advance to page 2 0 frames sent 0 frames overflowed buffer 0 frames received correctly 0 times no reply received in time 0 frames received with errors 0 frames aborted 0 undefined frames received 0 equipment errors page 2 next page reset Any key frames sent Number of SDLC frames sent to the host frames received correctly Number of SDLC frames received without errors frames received with errors Number of SDLC frames received with either CRC errors or frames shorter than two bytes indicated by an on the Communication Scope undefined frames received Frames received by BARR RJE that have an illegal SDLC control field or that are illegal in the current SDLC mode Indicated by an B on the Communication Sco
337. file This file contains the commands to execute when you power on or boot up the PC 2 S sS 72 W gt c cc cc i AN With Different Configuration Files Different mainframe computers require different BARR RJE configurations When you start BARR RJE you can specify a configuration file that contains configuration parameters for a specific mainframe 1 Create additional configuration files Chapter 19 describes how to create configuration files 2 Run BARR RJE from the DOS prompt with a parameter to specify a configuration file as follows barrsnar filename For example to run BARR RJE with the configuration file RJE CFG enter this command barrsnar rje cfg 322 20 1 Starting BARR RJE EFJ Monitoring the Connection Process When you start BARR RJE you begin communications at the Operation screen The Operation screen reflects the activity taking place while BARR RJE tries to connect with and log on to the mainframe CENTRAL HOST NAME COMMUNICATION SCOPE DRAXid XidrsnrmUaRrRr00 23 16 LPT1 10 normal Com1 0 CTS 0 14 57 10 Call 555 1000 for modem connection to central host computer Call 555 4210 for central host operator Call John Smith at 555 2345 for problems with PC Modem connection established Operation Command to Host Send Files to RD1 Advanced Quit Send Files to SCREEN Mount Forms Selection t gt The Operation screen is divided
338. file contains either an electronic printer form or other printer commands When the print file is ready to be sent to the printer BARR RJE searches the forms overlay directory for a beginning overlay file If the software finds an overlay file with the specified name it sends it to the printer before the print file If BARR RJE sends a beginning overlay file it checks for an ending overlay file and sends the ending overlay after the print file For a specific job you can use a beginning overlay file only or a beginning and an ending overlay file You cannot use an ending overlay file unless you use a beginning overlay file You must name the overlay files for the selected search method In most cases beginning overlay files must not have a file extension Ending overlay files must have the END extension The search name you select with this option is included in the spool header It is derived from form information obtained from one of the Mount forms by selections BARR RJE 287 ob oo im gz i gt an a i A i o r m SETUP PDIR provides form name FCB name job name and UCS name Operation screen provides form name m Power 1Q40A FORMNAME provides job name and form name m HASP190 message provides form name FCB name and job name For example if you set Search for form overlay by to FORMNAME you must create overlay files named for the form na
339. files write to the spool directory entries in the FAT can automatically set or override file attributes The software updates the attribute values in the file s spool header displays them on the Print Spool screen and uses them when the files print You can set attributes for individual files groups of files or all files You also can choose to maintain the FAT from the Installation Description or with an external FAT file For an example of what the table looks like see Maintain an Internal FAT later in this section FAT Options Screen You can enable the FAT from the File Attribute Table FAT Options screen To reach this screen start from the Print Spool Description screen Print Spool Description Spool printers 1 SPOOL directory C SPOOL Retain directory Escape Advanced Spool Options File Attribute Table FAT Options Initial SPOOL Printer Settings Enter number gt Select File Attribute Table FAT Options 9 5 File Attribute Table FAT File Attribute Table FAT Options Use File Attribute Table FAT No_ Match FAT entries using Filename Formname Type of FAT table internal External FAT file name Choice Use the first option on this screen to enable the FAT Use the rest of the options to control FAT operation o me 5 N r i D a ir 3 Ej Use File Attribute Table FAT Choose whether
340. from the LAN connections directory the software either deletes or renames the file If an error occurs during the delete or rename attempt the LAN device is suspended LAN1 SUSPEND on the Assign Devices screen To re enable the LAN device you must correct the error and then re assign the device to its original destination from the Assign Devices screen If you direct files from a LAN directory to the host LAN1 RD1 the device is not suspended if the SNA session is lost When the host recovers the LAN device continues to function and does not require operator intervention Using the Barr Move Command The Barr move command changes the location of a file by renaming the directory portion of the file name This method is faster than copying the file to a new location and then deleting the original file The move command for MS DOS version 6 0 automatically overwrites existing files The Barr move command does not overwrite existing files unless you explicitly specify the overwrite option The MOVE EXE file is provided with the Barr reference files Follow these guidelines when you use the move command BARR RJE 111 m The form of the command is move f path1 filel path2 file2 where f is the drive letter path1 is the directory where the original file is located file1 is the file name path2 is the new directory for the file and file2 is the new file name You can only move files to new locations on the same drive Th
341. fy the parameter SETUPMSG on the Remote Definition statement RMTnnnn For JES2 ESA specify SETUP MSG on the Remote Definition statement RMTnnnn Chapter 1 of the Barr Host Definition Guide discusses the JES2 Remote Definition i E i 2 E L L 524 F 3 Using FCBLOAD with HASP190 The job name information depends on the order in which the jobs are sent and might not be reliable The host sends the HASP190 message only when the form name changes This means if two jobs with the same form are received to the PC one after the other the second job will contain the same job name value as the first job For example assume the following jobs are received in the order listed The list below shows that on the PC JOB2 ends up with the same job name as JOB1 Job name Job name at Host at PC JOB1 FORM gt JOB1 FORM1 JOB2 FORMI1 gt JOB1 FORM1 JOB3 FORM3 gt JOB3 FORM3 The HASP190 message limitation should not be a problem unless you use the job name to determine when a file should print 3 Enable FCBLOAD and HASP190 in the Barr software Finally instruct BARR RJE to use the FCBLOAD and HASP190 information provided with the file You accomplish this with two options on the Barr software s Tuning and Global Options Printer Control screen m Set Use Barr FCBLOAD to Yes Set Mount forms by to HASP190 FCBNAME Set Disable form mount error messages to Yes Forms from the
342. fy type of 200 video adapter for 200 Monitor and Adapter screen 199 Monochrome display 41 201 308 monitor 41 200 video adapter 23 More memory needed for buffers 369 Mount Forms 216 233 350 518 disabling error messages 525 error message 286 examples 235 form list 234 form or FCB prompt 234 No Form option 235 options 283 screen 233 351 Move command 111 418 MS SNA Server 27 Multi tasking 26 Multidrop line 297 298 Multiple copies 410 Novell NetWare queue 117 PDIR 519 Multiple Logical Units 28 Multiple Session RJE 17 28 562 Index Multiscan monitor 200 MVS JES2 See JES2 MVS JES3 See JES3 N N ASCII lines receive mode 178 Native TCP IP port 86 protocol 83 Navigation through screens 33 NCCF 394 NCP 16 19 publications 5 NCR printers 93 control codes 97 NET Device Driver 167 NET device messages 357 NET Device screen 74 NET Options screen 89 NETI NET12 54 74 153 159 activity log 357 disable 75 enable 75 log operations 91 options 76 suspend 89 NetBIOS 14 NetView 375 394 application alerts 395 Operator Alerts 300 395 Operator generated alerts 397 398 NetView Alerts 375 NetView Response Time Monitor RTM 395 screen 396 Network maximum connections 77 114 print queue 77 113 server 77 113 Network Communications Control Facility NCCF 394 Network Control Program NCP 19 Network Logical Data Manager NLDM 394 Network Management Vector Transport
343. g execution S Start The command starts the specified device This command negates a P command for devices If a job is awaiting processing it becomes active Format Enter the 8 command as follows s dev where dev identifies the device Substitute one of these values CA D c lt x RDn to start reader n PRn to Start printer n PUn to start punch n Examples S RD1 starts reader 1 476 A 1 JES2 Remote Commands S PR1 starts printer 1 T Set Device Option The T command sets the device s attributes The T command has several operands and uses Format Enter the T command one of these ways T dev K 1 causes the job currently printing on dev to single space after each print line to the end of the dataset and ignore carriage control information supplied by the program Operators can use this command to prevent a job from skipping lines between data lines because of a programming error It single spaces to the end of the dataset currently printing and can be negated by the T dev K R command T dev F ffffffft sets the printer to the special form specified by ffffffff an eight character special form name The printer then only prints jobs with that special form name STD indicates the printer should print only standard or regular forms no special form was specified in the job 7 The printer must be inactive for this command to work Drain t
344. g on the keyboard use the TSR program BIOS_KEY included with the Barr reference files BIOS_KEY briefly turns off interrupts BARR RJE 367 adoag wwo ZZ 22 Comm Scope SDLC Examples DRAMEI xi dr Fabel UaltaRr io Normal dial up sequence DRARaeee Modem answered but NRZI probably needs to be changed See Chapter 2 of the Host Definition Guide for more information DRAVE lxi dr fee The Xid failed Probably IDBLK and IDNUM are not correct See Chapter 2 of the Host Definition Guide for more information Rr fear RRT ies Line is idle No information frames are being exchanged 012345 6Rriea7012345Rribe Host is sending information Remote is idle 01234Rr EEL wiinaa5 6 7012 3Rr Both host and remote are sending information 012645 6Rriha345 6701 Rribe Frame 3 received in error Communication resumed at frame 3 Dedicated Line Examples ua Ua BARR RJE can hear the host but the host cannot hear BARR RJE Try setting Constant RTS to Yes See section 18 4 Modem and Line Control for more information TrTTTI Try changing NRZI and then check your modem connection See Chapter 2 of the Host Definition Guide for more information Modulo 128 The Communication Scope tells you if the mainframe is operating in modulo 8 or modulo 128 mode At logon the host sends Snrm for a modulo 8 link or Snre for a modulo 128 link Even if you set the mainframe parameters to use modulo 128 and you see an Snre on
345. h 290 expand 57 72 Talk modem setting 453 Tape screen size 199 202 session not implemented 312 support 30 TAPE device 176 178 183 receive mode for 180 TCP connections 82 TCP IP 14 network 159 network interface 82 port 86 protocol 27 83 TCP IP LPR UNIX print queue 74 75 77 159 errors 361 options 82 Technical support iii 48 Telephone Barr Systems iii Telephone connection maintain after exit 298 Telephone numbers entering 259 on Operation screen 259 Test adapter 267 cable 267 268 DPI printer power off 59 failed 268 mode 306 452 modem 267 268 passed 268 plug 265 267 VTAM command 394 Test page reprint option 428 Test Result screen 268 Throughput 26 TIC 27 Tilde convert 1A to 68 Timeout message 367 370 372 Timeout period serial port input 70 Timeouts 802 2 382 SDLC 378 X 25 385 Timing delay printer 58 Token ring 14 Interface Coupler TIC 27 maximum frames outstanding 299 Token ring adapter 10 primary or alternate 299 Token ring address all zeros 361 error 361 Token ring logical link control LLC driver 299 Trace file 387 Trademarks 6 Trailer page separate file for 193 Trailing blanks add 291 JES2 truncates 291 Transfer Binary file format 454 Transfer files receive mode 181 send mode 343 Translate control codes ASCII 293 to Control codes 274 491 494 to Question marks 275 491 494 Translation table print queue 87 Translation tables 489 ASC
346. hat controls the operation of a communication controller It is generated by the user from a library of IBM supplied modules NetBIOS Network Basic Input Output System is a standard interface between PC software and LAN adapters such as token ring Ethernet or Arcnet adapters network An arrangement of nodes and connecting branches for information interchange non transparent transmission In bisynchronous communications an obsolete standard that does not allow transmission of all 256 characters non switched line See dedicated line Contrasts with switched or leased line Novell IPX Novell Internet Packet Exchange comes with the Novell LAN Novell has imple mented IPX for most LAN adapters in cluding Ethernet Arcnet and token ring NRZI In SNA communications a method of coding data transmission so that the sender changes the signal for a binary 0 to the opposite state and leaves the signal for binary 1 in the same state Also known as invert on zero coding NUL Device that deletes output offline Disconnected from the system Processing that is performed in isolation online Connected to the system Processing that is performed during direct communica tions between a workstation and a host computer operand A JES2 command used to modify a command or identify the job or system facility to act upon operating system A master program that manages the re sources of the computer The operating sys
347. hat performs a specific application or task such as word processing accounting or financial planning Contrasts with a utility or system program that is used to carry out file management and housekeeping functions APPLID In SNA VTAM communicates with many applications The APPLID is the identify ing name of a VTAM application ASCII American Standard Code for Information Interchange which specifies a set of 128 graphic and control symbols and their seven bit codes Extended ASCII supports 255 symbols ASCII is used by PCs and PC peripheral devices such as printers asynchronous communication A communications technique in which each character is transmitted as a discrete unit The character transmitted is preceded by a start bit and followed by one or more stop bits As each character is bracketed by start and stop bits varying amounts of time can elapse between characters Contrasts with synchronous communication Also called start stop communication attributes 1 Parameters that describe files and printers 2 For 3270 display character istics of a field or byte such as protected or underlined backup A procedure for making a duplicate copy of data that you can use if the primary data is lost or destroyed base software A Barr software product to which options can be added For example BARR RJE is a base software product to which options such as PRINT370 can be added BARR RJE 533 Messoj9
348. he 3 printer first with the P command and wait until the printer drains 2 before issuing the T command After each change of forms from S the T command the system displays a LOAD FORMS message on the 3 console when the next job starts on the printer Reply with the command T dev S ddd tells the system whether to print or punch separator banner and trailer pages or lines at the beginning and end of each job The operand ddd is either YES or NO Operators can use this option to write output to a PC disk BARR RJE 477 T dev Q class where class lists from one to eight SYSOUT classes to be processed by this device The default class is A for printers and B for punches T dev WS criteria specifies the work selection criteria to determine which jobs will be allowed to print on a device and in what order You can put one slash before or after a selection criterion A minus sign before the criterion removes that criterion from the list These criteria are commonly used W Before the slash the writer name for the output group must match the device s writer name After the slash matching is preferred but not necessary Q class Unless you specify output classes JES will search all output classes for work therefore always use the Q criterion Before the slash JES searches output classes in the order specified After the slash JES does not prioritize classes R destination route Before the slash the output g
349. he Host Definition Guide helps the host programmer with that task Contacting Barr Systems Electronically Booklet This booklet provides detailed instructions for contacting Barr Systems via Internet e mail the Barr web site and the Barr FIP server Common Questions Booklet This booklet lists 20 common questions about BARR RJE software and tells you where to find the answers in the BARR RJE manual Other Manuals If you purchased a communications adapter from Barr Systems an adapter installation manual is included If you purchased additional Barr software or hardware options to use with BARR RJE corresponding option or hardware manuals are included References These selected publications provide more information about communica tions concepts Refer to the publications that apply to your host system and data communications equipment The publication number for each manual corresponds to the version number of mainframe software The number for your publication might be different depending on the version of the software at your host JES2 XA JES2 Commands SC23 0048 JES2 Initialization and Tuning SC23 0065 1 3 References JES2 ESA JES3 VSE POWE VM RSCS VS1 RES DOS SNA 3270 3777 3 4 NCP VTAM _ 5 i 2 ix 5 JES2 Commands SC28 1039 JES2 Initialization and Tuning SC28 1038 JES3 Installation Planning and Tuning SC23 0041 JES3 Commands SC23 007
350. he default value is 5 minutes Decrease file priority on retry Choose whether to decrease the spool priority of files that are set to the Retry state No Default The file priority is not changed Yes Decrease the file priority by 1 This allows new files that arrive in the spool to print first when many files are set to the Retry state Otherwise the print spool might continuously cycle between the files on retry and delay printing any new files 90 8 5 NETI NET12 Devices Miscellaneous Printer Options for NET Devices Two printer options are available for each NET device gt From the Devices and Printers menu for the selected NET device select Miscellaneous printer options Miscellaneous Printer Options NET1 network type Novell Print Queue printer type Generic Log operations on console Yes Forms overlay directory Choice Log operations on console This option controls the console messages START NETn and END NETn These messages display when output is sent to a NET device Yes Default START and END messages display on the console when jobs are sent to the NET device No Status messages do not display on the console when jobs are sent to the NET device Forms overlay directory Use this feature to load electronic forms or to send additional printer control data or printer resources to the printer In this field enter the name of the directory where the overlay files
351. he file text 4 2 gt 7 i K Note If a file does not contain form feeds FF the software will search only the first 200 lines in the file for the specified spool header information Assign Devices Spool header s formname is on page 0 line 0 in columns 0 to 0 hoice When BARR RJE extracts the name from the specified location it does the following Skips leading blanks Terminates the file name if it detects a blank after a valid character within the column range For example if DAILY RPT is at the specified location the file name will be DAILY In the spool header form name or job name originates from the text class is set from the Class option and other fields have default values Special Use In exceptional cases you might not be able to obtain a form name or job name from any of the usual options including options set at the host JES2 HASP190 message or SETUPHDR record or in the Barr software OUTPUT statement used in file or Spool header from data For example if you receive files on the COM port the only way you can obtain the form name is from the data But you might not be able to change your programs to 190 10 9 Options for Assign Devices include the form name in the data Additionally the form name might not be in the same place in each of the received files so the information supplied by Spool header from data is not reliable Wh
352. he new form definition Example 2 Printing Checks This example shows how to create a form for printing checks The check form in this example includes a check stub and has a total length of 42 lines with 6 lines per inch Follow these steps from the Edit Forms menu Edit Forms select one Escape STD Selection l gt 1 Select a blank entry from the list Edit Forms Name CHECKS Lines per form 42 Print lines per form 42 Lines per inch 6 Printer control 00 Enter character 2 Enter the form name The form name you assign must match the form name specified in the host JCL for the job that generates the checks In this example the form name is CHECKS BARR RJE 223 _ oo im 53 a Bal i 3 a 3 Enter 42 for both the lines per form and the print lines per form 4 Enter 6 for the lines per inch 5 Press to display the Carriage Control Table screen Carriage Control Table The lines above the cursor show the form line numbers Enter carriage control characters 1 9 A B or C 000000000111111111122222222223333333333444 123456789012345678901234567890123456789012 1 234 5 6 8 Enter character Note that the length of the entry line reflects the value you entered for Print lines per form a E ras o a Gr pas 6 Enter the carriage control stops for the check Typically carriage co
353. he remote device cannot issue the INITSELF command you need to set Logon Type to Host Initiated on the RJE Description screen BARR RJE will issue a bind to RJE LUs after it receives a valid response to the ACTLU See section 26 4 for more information about how to use this feature Minimum number of LUs This option is useful only when Communication role is set to Host It specifies the minimum number of logical units LUs to be activated Maximum number of LUs This seldom used option limits the number of LUs that the software will activate For example if Maximum number of LUs is set to 8 and 10 LUs are requested only eight LUs will be allocated The maximum number includes LU1 which is allocated by the software whether or not it gets used This option might be useful in situations where the number of devices available is greater than the number of LUs needed It is valid when Communication role is set to either Host or Remote 296 18 4 Modem and Line Control Options for the SDLC Link These options affect the SDLC communication link Constant RTS Select whether to hold the Request To Send RTS signal constant on the communications line No Yes Default RTS is not constant BARR RJE enables the Request To Send signal when it is ready to send data to the modem The modem returns a Clear To Send CTS signal when it is ready to receive the data Note For either half duplex or multipoint multidrop communica
354. he software alternates between the two source devices looking for files to send to LPT1 First the software looks for a file on PR1 If a file is detected the data is directed from PR1 LPT1 until an end of file marker is encountered Then the software looks for a file on PU1 and routes it to LPT1 The software continues alternating between the two sources Example 2 VAX and IBM Computers Share a PC Printer BARR RJE can function as a printer sharing device for more than one host computer This feature allows several systems to share an expensive high speed printer without having to use additional printer sharing equipment 194 10 10 Assigning Several Sources to One Destination A common application is to share a high speed printer between a DEC VAX VMS minicomputer and an IBM mainframe computer running MVS JES2 The VAX is connected to a PC serial port such as COM1 to input data The IBM mainframe inputs printer files on PR2 1 Connect the VAX RS232 port to COM1 on the PC 2 Enable COM1 from the Devices and Printers menu 3 Under Serial Port Options set Use this device as a data Source as well as a Destination to Yes 4 From the Serial Port Source Options screen select the desired Input mode Length of end of file marker and End of file marker Select No for Card reader input _ A 2 5 S o D 2 Next make the device assignment 5 From the Assign Devices screen select COM1 and assign
355. header 433 PRINTDEF Novell utility 81 Printer 12 activity log 356 busy line 58 control codes 230 Dataproducts 22 32 destination 160 interfaces 12 31 laser 227 231 maximum print position 291 messages 356 multiple printers 21 offline 65 online 65 optimize performance 57 58 71 overdriving 59 print speed 21 requirements 12 reset string 92 103 See also RJE printer S 370 channel 12 31 special features 102 274 Printer attributes 147 406 Class 147 407 Form 147 406 State 147 406 Status 407 Units 407 Printer commands JES2 239 242 JES3 241 sent with forms 239 Printer control data 102 COM device 62 examples 104 230 forms with 219 229 LPT device 56 NET device 76 92 overlay files 100 processing 229 screen 102 Printer control index Edit Forms 219 229 230 PRT 437 spool header 509 Printer error alarm 59 dropped characters 58 duplicate characters 58 overprinting 358 recovery from 334 462 469 timeout interval 292 Printer forms 21 215 350 See also Forms screen 215 Printer Forms Commands Sent to Host screen 237 238 240 242 244 Printer Initialization screen 147 148 Printer options COM device 62 71 LPT device 55 56 NET device 76 91 Printer performance optimized 57 71 Printer resources overlay files 60 73 91 100 Printer sharing 193 for several hosts 194 Printer status parallel 324 serial 325 Printer test for power off 59 from BARR RJE 502 from DOS 502 Printer timing delay 58 Pri
356. hen you use one of these printers the Barr software sets only the lines per form You must manually set the lines per inch on the printer D P I Use this selection only with the BARR DPI adapter from Barr Systems The BARR DPI printer adapter and cable support all printers that use the Dataproducts Interface The adapter can be configured for the devices LPT1 LPT2 or LPT3 and is fully compatible with BIOS and DOS The adapter is available in both long line and short line versions The cable is available with either a Winchester connector or a D type 50 pin connector Because the Dataproducts VFU feature is fully implemented in Barr software the printer can jump directly to a specific line without printing blank lines This results in faster printing The BARR DPI adapter also supports extended ASCII codes eight bit data such as the cent sign To use the extended ASCII codes on the Miscellaneous Printer Options screen set Enable VFU 94 8 6 Choose Printer Type download into printer to No This disables optimization but has no other effect on printing If you do not disable optimization you will get errors in the printed output Use of extended ASCII codes also disables the Paper Instruction PD line With regular ASCII format seven bit data the eighth data bit is sent to the printer s PI line The PI line is driven only for printer control data or DAVFU commands With extended ASCII format the eighth data bit is
357. hen you use the reprint feature to resume printing the software uses this value and the fast reprint page number stored in the next field to immediately reposition the file at the correct starting point 00000048 Fast reprint file page number Maintained internally by BARR RJE if you enable the Save fast reprint repositioning information option on the Print Spool Description s Advanced Spool Options screen 512 E 4 Field Descriptions F Form Information Sources This appendix describes how you can set parameters at the host computer and options in the Barr software to obtain printer form information Form information is required if your print jobs have different print formats For example some jobs might print at a vertical density of 6 lines per inch while others might print at 8 lines per inch This appendix describes several ways to obtain form information It also provides checklists to help you decide which method best meets your printing needs and step by step instructions for implementing each method FA Obtaining Form Information This section presents an overview of the methods you can use to obtain form information The rest of the sections in this chapter describe each method in detail and help you decide which one best suits your application What are Forms A form can include print format information and a form name Most print applications require format information Format information includes lin
358. her problems Others help you provide Barr Technical Support with information to diagnose your problem gt To access diagnostic programs start at the Operation Advanced Diagnostics menu Standard Diagnostics The Diagnostics menu for BARR RJE looks like this Diagnostics Statistics Hardware Queries Link Diagnostics Escape Memory Dump Selection l gt Statistics Display product options and buffer statistics See section 23 1 Link Diagnostics Access diagnostics for the communications link including Communications Statistics Line Trace Bind Data VTAM Commands and NetView See sections 23 2 through 23 7 N oo o Ej 3 9 K Ss an o an Memory Dump Provide information for Barr Technical Support to diagnose unusual communications problems See section 23 8 Hardware Queries Display information about the Barr adapters installed in your PC See section 23 9 Escape Exit diagnostics BARR RJE 373 Software Option Diagnostics If you purchased software options such as PRINT TWINAX or BARR PRINT for LAT that allow you to communicate with more than one host other options might display on the Diagnostics menu For example if you purchase PRINT TWINAX the option Twinax Diagnostics allows you to access diagnostics for PRINT TWINAX as shown on the following screen Diagnostics Statistics Memory Dump Link Diagnostics Hardware Queries Twin
359. hese steps from the Edit Forms menu Edit Forms select one Escape a E o uu Selection gt 1 Select a blank entry from the list Ge EEs Edit Forms Name STD Lines per form 66 Print lines per form 66 Lines per inch 6 Printer control 00 Enter character 2 Enter STD for the form name The form name you assign must match the form name specified in the host JCL for the job which generates the checks listing In this example the form name is STD 3 Enter the values for the remaining options The standard form usually has 6 lines per inch and 66 lines per page so you might want to use the default values 4 Press to display the Carriage Control Table screen Carriage Control Table The lines above the cursor show the form line numbers Enter carriage control characters 1 9 A B or C 000000000111111111122222222223333333333444444444455555555556666666 123456789012345678901234567890123456789012345678901234567890123456 1 Enter character 222 13 2 Edit Forms 5 Enter the carriage control stops for the standard form Usually the standard form has only one carriage control stop a 1 on the first line of the page On the screen a 1 stop is defined for line 01 by default 6 Press Enter Edit Forms select one Escape STD Selection l gt The form list is updated to reflect t
360. hether the Barr software sends the control file first or last This option is valid only if you select the line printer daemon protocol No Default The software sends the control file last Yes The software sends the control file first n o 2 E a 3 G a a Fq oa Control file Class field is You can customize the value of the class field in the control file that the Barr software generates This option is valid only if you select the line printer daemon protocol not used Default The class field is not used in the control file FORMNAME The class field contains the form name JOBNAME The class field contains the job name Use native TCP IP port This option is valid only if you select the native TCP IP protocol Specify the port number that identifies the host connection The default port number is 9100 You can change the value in this field or you can specify a value in the Print queue field The value from this field or the Print queue field also displays in console messages indicating device activity 86 8 5 NETI NET12 Devices FCB FORM to Print Queue Translation Table On the Network Printer Options screen if you select FCBNAME or FORMNAME as the print queue name and press Enter the FCB FORM to Print Queue Translation Table screen displays The translation table is used to route files to specific print queues based on the FCB name or form name in the spool header On
361. his chapter groups scope characters by the type of communications activity they represent and then by the mainframe connection type The screen displays different scope characters for SDLC 802 2 and Coax connections adoag wwo ZZ X 25 connection Uses the same Communication Scope characters as SDLC connections Async connection A numeric return code displays on the Communi cation Scope when the PC connects to the mainframe but the return code meaning depends on the modem type Your modem manual explains asynchronous return codes 363 E23 Dial Up Scope Characters To follow BARR RJE s progress while it tries to connect to the mainframe watch the Communication Scope Dial up scope characters see Table 22 1 display in white For instance you can see if BARR RJE dialed the phone number if there was no answer or if the line was busy Table 22 1 Dial Up Scope Characters Character Description A Answer tone Host modem sent answer tone to remote Busy Host modem is busy Dialing In the process of dialing B D N No answer No answer tone has been detected Modem redials R Ringing Host modem is ringing Dial up scope characters usually appear in sequences on your Communication Scope For example DB DRA DRND 22 Comm Scope Dialing Busy Dialing Ringing Answer Dialing Ringing No answer Redialing EZE SDLC Connection After the PC connect
362. hoice Enable one of the following options and press to save your software settings You must save your changes to the program file or to a configur ation file or the changes will be discarded Save changes to C BARR BARRSNAR EXE file Select whether to save your configuration changes to the BARR RJE program file The directory path where the program file is located displays automatically Yes Default Save your changes to the program EXE file No Do not save your changes to the program file BARR RJE 315 19 Exit and Save Save parameters to a configuration file Select whether to save the configuration settings to a separate file No Default Do not save changes to a separate configuration file Yes Save changes to the configuration file you specify When you start the BARR RJE program you can specify the name of a configuration file that contains the desired installation settings The program uses the settings in the configuration file instead of settings you saved to the program file You could use a configuration file for the following applications a You can use a configuration file to move your configuration settings to a new version of the program a If you need to communicate with more than one host computer you can save separate configuration files with the unique communication settings you need for each host you contact You can use configuration files to change the way the soft
363. iagnose unusual communications problems See section 23 4 Bind Data In SNA communications bind data defines the operational rules for each party on the session Use this option to view the bind data for a communications session See section 23 5 VIAM Commands Send a VTAM command from any LU Often used to verify that VTAM is operating See section 23 6 NetView Provides information about SNA network operation and performance If your host computer supports NetView you can set BARR RJE to use it This option displays only if you enable NetView Alerts in BARR RJE under Tuning and Global Options Modem and Line Control See section 23 7 BARR RJE 375 N oo o Ej 3 D K Ss an o na an S a D S a E E o m N EEJ Communications Statistics You can view statistics for the SDLC 802 2 Coax and X 25 connections 1 To access Communications Statistics start at the Link Diagnostics Diagnostics screen Diagnostics Communications Statistics VTAM Commands Line Trace NetView Bind Data Escape Selection l gt 2 Select Communications Statistics 0 lines read 0 real buffers in use 0 lines printed or punched 126 real buffers free 0 SNA sessions active 0 XMS buffers in use 0 XMS buffers free Statistics since 16 08 02 page 1 next page reset Any key A time stamp on the first Communications Statistics screen indi
364. ice Default Select this option to enable the SEND device You must enable the device before you can use it The selected SEND device displays as a source device on the Assign Devices screen It becomes active as soon you assign it to a destination other than SUSPEND Additionally the Send Files command displays on the Operation screen Delete this device Disable the SEND device and remove it from the Assign Devices screen The status deleted displays next to the device name at the top of the screen The Assign Devices screen is easier to read if you disable devices you do not intend to use Additionally the Send Files command is removed from the Operation screen oo i oO S o D a 9 Ss s m 3 a a Escape Select Escape or press the key to return to the Devices and Printers menu ERT LAN1 LAN4 Devices The Barr LAN devices let users on the network route files with BARR RJE software Network users can route their files to any BARR RJE destination device For example they can submit jobs to the mainframe Because this feature functions as if network users were connected to the Barr PC it is called LAN connections A LAN device is a network directory that BARR RJE checks at regular intervals When it finds a file in the directory BARR RJE routes the file to the destination specified on the Assign Devices screen You can specify up to four LAN devices and assign each device a different directory and a differ
365. ice driver destination For example if you set PRI NET1 and you define NET1 to write to the print queue PUBLISH a message with this format displays START NET1 PR1 output to PUBLISH END NET1 If you route files to Novell or TCP IP LPR print queues SPOOL1 NET1 and a file transfer fails you might see a message with this format HOLD NET1 CHECKS JOB on SPOOL1 You can set up the software to automatically retry the transfer when this condition occurs See NET Options in section 8 5 Line Trace Activity When you enable the line trace as described in Chapter 23 additional device activity messages display on the console CON has begun CON has ended PR1 has begun The messages stop displaying when you disable the line trace N o gt J eej gt J amp m i 3 2 i 5 Warning Messages You might see these warning messages on the console Memory Buffer Shortages When the number of DOS buffers available to the program falls below 20 the following message displays Warning less than 20 free buffers remain This message indicates that you need to increase the value of Memory allocated for buffers under Tuning and Global Options Trace and Memory Options Also see section 23 1 Statistics BARR RJE 357 Extended Memory Buffer Allocation If you allocate more extended memory buffers than are available the following message displays at software startup indicating the actual number of ex
366. ice set LOG NUL to discard any data received from the log source device The NUL destination is enabled automatically and cannot be removed from the destination list BARR RJE 157 4 2 gt 7 i K SUSPEND LPT1 COM1 Setting a device to SUSPEND temporarily disables it For example PR1 SUSPEND indicates that no data can be received to the PC from the RJE printer You might want to disable the data flow for a short time while you service a PC printer On certain error conditions BARR RJE automatically sets a source device to SUSPEND Do not set active devices to SUSPEND for long periods of time While a device is suspended data continues to flow into BARR RJE Because the data is not directed to a destination it fills memory space needed by other software features and results in reduced software performance To disable a device permanently disconnect the physical device from the PC or disable the source device from the corresponding installation screen The SUSPEND destination is enabled automatically You cannot remove it from the destination list LPT3 The LPT destinations route data to a parallel printer attached to the corresponding parallel port LPT1 LPT2 or LPT3 For example PR1 LPT1 routes data from RJE printer 1 PR1 to the printer attached to the PC s LPT1 port You can enable the LPT devices from the Devices and Printers screen as described in section 8 3 coM4 The C
367. ice when you intend to print the files you receive to the print spool Yes Strip the spool header when you write a file to disk This choice works best when you do not print spool files Other Options These options do not affect the Barr spool header Ignore _ lines from start of file This option lets you delete a specified number of lines from the beginning of the file The maximum value is 32767 A common application for this option is to delete the first two records of a punch file the blank card and the file separator card Another way to eliminate the beginning separator records is to modify the host definition or issue a host command For example specify NOSEP on the JES2 Remote Printer or Remote Punch statement to eliminate separator cards between mainframe datasets Or issue this JES2 Remote Set command at software startup T PR1 S N This option is not valid for the SENDn or LANn source devices 192 10 9 Options for Assign Devices Create separator files Choose whether to divide an output file into multiple files by using Peripheral Data Information Records PDIR as file boundaries This feature is valid only for the RJE print streams PR1 to PR7 RJE systems such as JES2 insert PDIRs into output files if SETUPHDR or PDIR job separators are enabled PDIR records include job name form name FCB name and copies information These records typically occur several times in a file usually before the banner page
368. ies using option File Attribute Table Set file attributes for print spool Filename Form State Class Prty Copies Disposition DEFAULT DEFAULT Enter character BARR RJE 137 As files are received to the print spool the software compares their spool headers to the match criteria of each table entry The override values in the table are used only if the match criteria in this example Filename and Form of the file matches a table entry When override values are applied to a file they are saved to the spool header and displayed on the Print Spool screen If you specify both of the match criteria for example Filename and Form in a table entry then both values Filename and Form from the file must match the values in the table If a table entry contains only one match value only that value must match For example if you specify the Filename in the table but leave the Form blank only the Filename must match If you specify the Form in the table but leave the Filename blank only the Form must match i o N o a i A a oa Multiple Matches If more than one table entry matches the file the software applies each matching entry cumulatively beginning with the first entry of the table For example if there are two matching table entries the software applies the attribute changes from the first matching entry followed by the changes from the second matching ent
369. if you select Austrian German Alternate the following message displays The translation tables have been modified for language Austrian German Alternate You can select Edit translation tables to see these changes or to make additional changes Edit Translation Tables Typically you do not need to edit the translation tables Table changes are required only for special applications or printing needs For example if your printer cannot print lowercase letters you can change the translation tables to convert from lowercase to uppercase text BARR RJE 277 When you select the Edit translation tables option the translation tables display Three tables are available one ASCII to EBCDIC table and two EBCDIC to ASCII tables The software uses ASCII to EBCDIC Table One when you send data to the host on a reader device RD1 to RD4 The software uses EBCDIC to ASCII Table One or EBCDIC to ASCII Table Two when you receive data on a print stream PR1 to PR7 or punch stream PR1 to PU4 Note 1 The two EBCDIC to ASCII tables are not identical See section B 5 for a list of the differences between table one and table two Note 2 If you need to use one of the first three options Translate control codes to Control codes Translate control codes to Question marks or Choose Language for translation tables you must select it before you modify the translation tables If you select one of these options after you edit the tra
370. ifferent state for each spool printer Ready Default At software startup files begin printing immediately if E their file attributes match the spool printer criteria 5 2 Reprint A file enters the reprint state if its file attributes match the e spool printer criteria Before the file can start printing the PC lt operator must position the file at the location where reprinting will begin r Disabled The spool printer is disabled Files will not print until the operator changr he printer state on the Print Spool screen Form If you want to print files that have a certain form name at software startup enter a form name The form name can contain up to eight characters You can include the DOS wildcards and in the form name to select groups of forms If this field is blank the form name is not used in the print selection criteria Class If you want to print files that have a certain class at software startup enter one character class names The class name can consist of either a number or a letter Files copied into the spool directory from DOS are automatically assigned a class of Z unless you assign a different class with the PRT program or the FAT You can enter up to five classes for each printer If this field is blank class is not used in the print selection criteria 148 9 7 Initial Spool Printer Settings Chapter 10 Assign Devices The Assign Devices screen displays the source and de
371. iles being received This feature allows external programs to determine when new data is present without having to wait for the end of the file to be received Valid values range from 10 to 998 seconds The default value of 999 disables this feature BARR RJE 309 Session and Security Options Several options allow you to disable access to certain software features and affect the sessions you use during BARR RJE operation gt From the Tuning and Global Options screen select Session and Security Options Session and Security Options Disable Installation Description No Disable Receive mode in Assign Devices No Disable DOS session No DOS session executes AUTOCMD BAT No Initial session is OPER Hot key uses Ctrl Alt Enter number Disable Installation Description Choose whether to disable the Installation Description This prevents PC users from viewing or changing the installation options No Default The Installation Description is not disabled PC users can access the installation screens a i A i o r Yes Disable access to the Installation Description screens to prevent users from viewing or changing the software configuration With this choice BARR RJE does not display the commands on the Commands Sent at Startup screen as they are automatically sent to the host This is a security feature that hides passwords used for logon to the host computer
372. iles that are received when the No form selection is assigned If carriage control stops occur in the files and a Carriage Control Table is not defined the stops will be handled as follows a Where a 1 stop occurs in a file the software advances the paper to a new page oo mz 53 o Bal i 3 an u Where stops 2 to 12 occur in a file the software advances the paper one line Scroll Feature for Forms Display Only 32 forms display at a time If you define more than 32 forms use the scroll feature to display the additional forms A scroll prompt Scroll gt displays in the bottom left corner of the screen Follow these steps to use the scroll feature 1 Use the or 4 keys to move the cursor to the scroll prompt 2 Put your cursor on the arrow that indicates the direction you want to move either to the previous screen or the next screen and press E A vertical bar displays in the scroll prompt when you reach either the beginning Scroll gt or end Scroll of the list Mount Forms Examples When you mount forms the screens differ slightly depending on whether you have defined only one printer or several printers The following examples show how to mount forms in each case Example 1 Assign a Form when One Printer is Defined This example shows how to assign a form if you have defined only one RJE printer When you select Mount Forms a list of forms displays BARR RJE
373. in binary format enter the following Enter file names To combine files separate by a plus To start a new file leave a blank To cancel press Esc Files JCL DATA1 B DATA2 B BARR RJE 343 Because ASCII is the default you do not need to specify a send mode for the JCL file This file contains job control statements and program ming statements The DATAI file is transmitted as 80 byte records without translation a The DATA2 file also is sent as 80 byte records without translation a If the last record of DATA does not contain 80 bytes the first record from DATA2 is still treated as a separate record Data from the DATA2 file does not get combined with the last record of the DATA1 file Cancel a Send Files Command You can cancel a Send Files command before BARR RJE finishes executing it gt Select the Send Files command again If the previous Send Files command has not finished the following screen displays A previous command is still active Cancel previous command No Choice Cancel previous command Choose whether to cancel the previous send command i o a i Wu c gt s c co rr N No Return to the Operation screen Files continue to be sent Yes Cancel the previous Send Files command The host is notified that the file transfer has been canceled Send Files with an Embedded Command You can s
374. in Data Set Ready Used for flow control by DOS Can be used for flow control by BARR RJE To be compatible with DOS pin 6 should be tied to pin 5 7 SIG GND Signal Ground 20 DTR out Data Terminal Ready Used for flow control when receiving on a COM port BARR RJE will set this to 0 to signal the remote device to temporarily suspend data transmission Note The terms 0 and 1 for electrical signals mean LOW and HIGH BARR RJE 497 oO N o D paz i e 53 o g ix o C 2 Signals for 9 Pin Serial Ports Signals for the 9 pin serial port connector on the PC are as follows Pin Number Name _ Direction Description 3 TXD out Transmit Data 2 RXD in Receive Data Used for XON XOFF flow control and receive data 7 RTS out Request To Send BARR RJE always sets to 1 8 CTS in Clear To Send Used for flow control If CTS 0 then no data will be sent This line can be jumpered to RTS to force CTS 1 6 DSR in Data Set Ready DOS uses for flow control BARR RJE can also use for flow control To be compatible with DOS pin 6 should be tied to pin 8 SIG GND Signal Ground 4 DTR out Data Terminal Ready Used for flow control when you receive on a COM port BARR RJE will set this to 0 to signal the remote device to temporarily suspend data transmission Note The terms 0 and 1 for electrical signals mean LOW and HIGH KEJ Printer C
375. in directory files If you enabled the retain directory feature choose whether old retain files are automatically deleted You can use this feature to periodi cally free disk space when you retain a large number of files No Default You must manually delete files from the retain directory When you retain a large number of files you should periodically delete the files from disk so they do not fill the hard drive Yes Retained files are deleted automatically when the specified retain period expires Set the retain period with the next option Retain files for _ days Specify the number of days that files are retained before the software automatically deletes them The default retain period is 7 days Each time BARR RJE starts and at midnight when the PC system date changes the software compares the file date and time to the current PC date and time and deletes any files that exceed the retain period When you choose a retain period consider how many files you want to store at one time and how many files your hard drive can hold BARR RJE 133 i o N a i A a oa This option is valid only if you set Delete old Retain directory files to Yes It works best when you set Use current date and time when retaining files to Yes KEJ File Attribute Table FAT The FAT automatically sets file attributes for spool files and is especially useful for unattended print spool operation As
376. in options 124 9 3 Print Spool Description Screen KEJ Advanced Spool Options You can specify advanced options that affect print spooling These options give you more control over spool display and operation Print Spool Description Spool printers 1 SPOOL directory C SPOOL Retain directory Escape o m 5 i 2 i D a ir e 3 Ej Advanced Spool Options File Attribute Table FAT Options Initial SPOOL Printer Settings Enter number gt From the Print Spool Description screen select Advanced Spool Options Advanced Spool Options Control spool with Formname Display FCB name on spool control screen No_ Start printing before end of file is received Yes Sort spool files by Prty gt Date lt Time lt Sort retain files by Date gt Time gt Allow operator to modify file attributes Yes Check SPOOL directory for new files every 300 seconds Log operations to LOG device No_ Include spool header only once during reprint Yes Save fast reprint repositioning information No Display spool header information on Retain directory screen Yes Use current date and time when Retaining files Yes Delete old Retain directory files No_ Retain files for 7 days Choice The options on this screen fall into three categories spool options reprint options and retain options BARR RJE 125 Spool
377. ines Follow these guidelines when you define function keys a Use the arrow keys to move within a key entry The or Q key jumps to the beginning of the line Enter a description on the first line to remind you about each key s function You can define a single function key to issue several commands consecutively If you enter more than one command for the key separate each command with a vertical bar To change a key definition type over the existing text To delete a key definition use the to remove all characters Use the key to move to the next function key entry Press after your last key edit and then press to exit the screen 246 14 2 Entering Key Definitions Changing a Function Key Definition This example shows you how to change the and definitions to reflect your JES2 remote number 1 From the Function Keys screen select Fl to F10 to reach the Function Key Definitions screen Function Key Definitions F1 Display all jobs DJ1 9999 F2 Status of remote DU RMT15 F3 Display forms queue DF F4 Display all output DN Q OUT F5 Drain printer 1 P PR1 F6 Interrupt printer 1 I PR1 F7 Start printer 1 S PR1 F8 Restart printer 1 E PR1 F9 Delete time stamp T RMT15 MFORM J F0 Backspace 2 pages B PR1 2 bk gt 7m i 53 ix r 5 A lt a Enter character
378. ing from some files Yes Default At the end of each file the software determines whether a form feed is included or whether the maximum page length is reached One of these conditions is necessary to ensure that the next file begins at the top of a new page If neither condition is met the software adds a form feed The software remembers if it adds a form feed and if the next file contains a form feed at the beginning the software removes it to prevent printing a blank page No Form feeds are not added to or removed from files Make all files have an even number of pages Choose whether all files should have an even number of pages for easier job separation No Default The number of printed pages can be even or odd BARR RJE 57 Yes Ifa file has an odd number of pages add a blank page to make the number of pages even This ensures that the job banner page always faces up on the fan fold paper stack Enable VFU download into printer This option displays only if you select a printer that supports Vertical Forms Unit VFU download on the Choose Printer Type screen Printers that support VFU include Dataproducts D P L Genicom Linewriter Printronix Sand Fujitsu Hitachi or STC D P I For a complete list of the printers with VFU capability see Lines per form and Lines per inch in section 8 6 n o 2 E a 3 G a a Fq oa No Default Do not use VFU to control line skips This ch
379. ing and receiving files You can send files manually by assigning SEND1 RD1 and issuing the Send Files command from the Operation screen You can send files automatically by setting up the LAN connections feature and assigning LAN1 RD1 You can receive files automatically by assigning file sources to destinations such as PR1 SPOOL and PU1 FILE This chapter discusses how to use commands on the Operation screen s command menu to send files and perform other functions related to file transfer You also can monitor BARR RJE activity by viewing console messages For information about the Communication Scope on line 1 of the Operation screen see Chapter 23 For information about the Status Line on line 2 see Chapter 20 See the BARR TRAN manual for information about enhanced file transfer functions N _ o gt J eoj ps J amp m i 3 2 5 From the Operation screen s command menu you can send commands to the host transfer files perform advanced operations mount printer forms and quit BARR RJE 333 CENTRAL HOST NAME COMMUNICATION SCOPE DRAXidXidrsnrmUaRrRr0 0 23 16 LPT1 0 normal COM1 10 paper 14 57 10 Call 555 1000 for modem connection to central host computer Call 555 4210 for central host operator Call John Smith at 555 2345 for problems with PC Modem connection established Operation Command to Host Send Files to RD1 Advanced Quit Send Files to SCREEN Mount Form
380. ing of 522 resetting 292 FCB name ending of file name is 164 See also File attributes form overlay file 288 HASP190 163 282 283 285 521 PDIR 516 route files by 79 SETUPHDR 283 spool control 126 spool display 126 spool header 510 translation table 79 87 work selection criteria 284 286 FCB FORM to Novell Print Queue Translation Table 87 FCBLOAD 95 519 Barr option 281 286 525 enabling 524 halve 282 HASP190 with 514 519 JES2 parameter 524 JES3 LDENS parameter 524 PSERVIC parameter 524 values supplied by 520 FEP 19 27 FF See Form feed character File line trace 387 messages 355 receiving during line trace 388 File Attribute Table FAT 134 enable 135 entries 137 143 external 137 143 428 internal 136 141 match criteria 135 137 139 maximum number of entries 141 override values 137 139 sample 142 screen 135 137 141 File attributes 407 changing 407 416 Class 140 189 409 437 Copies 140 410 437 519 Date and Time 410 descriptions 509 Disposition 124 141 FCB name 139 409 437 File name 139 Form name 139 409 437 Job name 139 Priority 140 409 437 setting 506 Size 410 See also Spool file attributes See also Spool header State 140 408 437 510 FILE device 153 157 191 assigning as destination 161 assigning LOG to 173 log files received to 166 352 354 355 route mainframe output to 169 File extensions automatic generation 166 167 FILE device 165 form overlay 287 289 LAN re
381. inishes You can use this option to override the wait feature No Default If a process is in progress the Waiting for processes to complete message displays When the process completes the software exits Yes Forces the software to exit after a manual disconnect or after idle time is exceeded even if processes are not complete The software abruptly exits instead of displaying the Waiting for processes to complete message Before you use this selection make sure that unfinished processes will not be critical to production BARR RJE 313 ah oo im kzi i gt a Notes a i 2 So D 5 co 314 18 9 Miscellaneous Options Chapter 19 Exit and Save Changes After you enter BARR RJE configuration settings you can select Exit and Save Changes from the Installation Description menu This option writes your configuration changes to the BARR RJE program file or to a separate configuration file If you do not use this option BARR RJE will not save your installation changes EAJ Exit and Save Changes Screen gt From the Installation Description menu select Exit and Save Changes Exit and Save Changes Save changes to C BARR BARRSNAR EXE file Yes BARS pue XZ 6L Save parameters to a configuration file No Configuration file BARR CFG You can make additional changes later by executing the DOS command C BARR BARRSNAR EXE I C
382. inted or punched 150 real buffers free 0 SNA sessions active 0 XMS buffers in use 0 XMS buffers free page 1 next page reset Any key lines read Total number of data lines read by the Send command or LAN connections and sent to a destination by BARR RJE lines printed or punched Number of data lines received on the host print or punch stream to the Barr PC an S a D S a E E o m N SNA sessions active Number of SNA RJE sessions currently active including printers punches readers console and commands from the keyboard real buffers in use Number of DOS communication buffers in use by BARR RJE real buffers free Number of DOS communication buffers available to BARR RJE Do not let this value reach 0 or the results might be unpredictable To be safe real buffers free should not fall below 20 during maximum use 380 23 3 Communications Statistics XMS buffers in use Number of extended memory communication buffers in use by BARR RJE XMS buffers free Number of extended memory communication buffers available to BARR RJE Do not let this value reach 0 or the results might be unpredictable To be safe XMS buffers free should not fall below 50 during maximum use Conversely if XMS buffers free is around 200 then XMS has been over allocated Page 2 802 2 SAP Statistics gt Press to advance to page 2 802 2 SAP Statistics 2 frames sent 10 SAP buffers availab
383. inters Sort t PgUp Help Files Check Spool PgDn Escape Restore The Barr PRT utility is the preferred method because it builds a spool header and lets you set attributes for the file unlike the Barr move command or DOS copy command See Chapter 25 for more information about the PRT utility The Barr move command requires the file source and destination directories to be on the same hard drive It eliminates copy time because it changes the file location by renaming the directory portion of the file name Unlike the copy command the Barr move command does not replace a file that has the same name unless you explicitly specify to do so The move command for MS DOS version 6 0 automatically overwrites existing files If a file with the same name already exists in the directory an error message displays The MOVE EXE file comes with the BARR RJE reference files You can run it from a DOS prompt as follows move d path1 file1l path2 file2 where the optional d parameter specifies to overwrite a file with the same name path1 file1 specifies the source path and path2 file2 is the destination path For example you can move TESTFAST JOB from C BARR REF to C SPOOL without overwriting a file of the same name with this command move c barr ref testfast job c spool gt Select for the Check Spool command BARR RJE 419 i a f i i 72 i Q N
384. into four parts The Communication Scope monitors the link to the mainframe a The Status Line displays the status of printers and other PC devices N o Pol J J J as m a D The Console displays both diagnostic and status messages The Command menu lists available commands Communication Scope Your host name and the words Communication Scope appear on the top line of the Operation screen The Communication Scope displays communication activity between your PC and the host Chapter 23 describes the Communication Scope Status Line The second line on the Operation screen is the Status Line It displays the status of devices and the time of day Device status information includes the number of lines received and sent parallel printer status and serial printer status A vertical line separates the device fields BARR RJE 323 Line Status Fields 23 16 23 Number of lines received 16 Number of lines sent SDLC Connections DSR 0 appears instead of the line status until BARR RJE connects to the mainframe Parallel Printer Status Fields LPT1 10 normal LPT1 Printer for which information is displayed that is LPT1 LPT2 or LPT3 10 Line in the file the printer is currently printing normal Current status of the printer as follows normal Printer is functional 2 cS sS 72 W gt es mnia cc cc lt i AN busy Printer is too busy to acc
385. ion l gt 3 Select Response Time Monitor Note For the Response Time Monitor option to appear on your screen you must have RJE 3270 an bA The Response Time Monitor screen displays D amp Session 1 Response Time Monitor 0 0 0 1 0 a Measurement First Character 1 1 0 2 0 E Time intervals set by local 2 2 0 5 0 LTTI 2 0 2 5 0 10 0 xc Next Previous Edit Escape 1 10 0 oO N Session Indicates for which of the four 3270 sessions RTM data is displayed Measurement Describes the end of the transaction parameter Select the action that stops the transaction timer Choose from the following actions First Character When the software writes the first character on the screen from the host 3270 data stream Keyboard Unlock When the software detects that the keyboard is available as indicated by the 3270 and SNA data stream commands The 396 23 7 NetView software must receive Change Direction CD and Write Control Character WCC must be set to restore keyboard or the software must receive the End Brackets EB command CD EB When the software receives the CD or EB commands Same as Keyboard Unlock except that the WCC restore does not have to be present Last Character When the software writes the last character on the 3270 screen from the data stream Time intervals set by Indicates who sets the time intervals Local The local operator sets
386. ion 245 246 249 250 256 disabling 256 Commands executing with function keys 245 JES2 remote 459 JES3 remote 481 repeating 249 sending at startup 257 258 VSE POWER 485 Commands Sent at Startup preventing display of 310 screen 257 258 Common Questions booklet 4 Communication Link screen 19 tuning options 295 Communication links 13 Communication scope 29 323 monitoring logon 330 Communications 18 controllers 14 multidrop shared line 298 publications 6 role 296 457 start time 295 Statistics 375 376 Communications speed SME cable 298 Comparex printers 31 Compressed print control codes 105 example 230 Computerm gateway 27 CON device 153 176 186 See also Console log file Concatenating files 340 Conditional new page at end of file 57 72 CONFIG SYS file editing 38 Configuration automatic 23 backup 317 modifying 318 peripheral device 12 saving 315 316 318 319 Configuration file 318 322 naming 316 319 Connect link 338 Connect to host 323 326 338 Connection option AT modem 209 Dataphone 2224B 207 Console 11 326 features 352 scrolling rate 309 353 writing files to 157 Console commands disabling 256 Console log file 155 enabling 173 file activity 166 NET device activity 91 spool activity 130 viewing 353 Console messages 352 at startup 326 delayed startup 295 enabling 155 166 file name error 172 indicating errors 330 331 logging 173 NET device activity 91 Contacting Barr Systems Electronic
387. ion values blank in a new control file default values from SPOOL CTR are used Spool Controls SPOOL directory C SPOOL Retain directory Spool filename Copies 1 Priority 5 Class 1 State READY Printer control 00 Formname Fcbname Jobname Lines per inch 6 Lines per form 66 Print lines per form 60 Local Disposition NOCHANGE BARR SPOOL Disposition RENAME Use file separator headers YES ASCII ASA NO Enter spool directory gt Use the Q and f keys to move between fields For fields that have selectable values use the to display the list of choices SPOOL directory Directory in which the spool files are located Include the drive name and full directory path This directory should be the same spool directory defined in BARR RJE Retain directory Optional directory where a copy of the file is retained after the file is copied to the spool directory Include the drive name and full directory path When you specify a retain directory and the file disposition is RENAME a copy of the original file is put in the retain directory after copying to spool and the file is deleted from its original directory Note This directory is different from the spool retain directory discussed in Chapter 9 A file is written to the PRT retain directory after the file is copied to the spool directory A file is written to the spool retain directory after the file prints Spool filename File name to use in the
388. is Closing Parenthesis Asterisk Plus Comma Cedilla Hyphen Minus Period Decimal Point Slant Digits 0 through 9 Colon Semicolon Graphic Characters D d e a m P D Less Than Equals Greater Than Question Mark Commercial At Uppercase Latin Letters Opening Closing Bracket Reverse Slant Circumflex Underline Opening Single Quotation Mark Grave Accent Lowercase Latin Letters Opening Closing Braces Vertical Line EBCDIC only Tilde Cent IBM Extension Logical Not IBM Extension Logical Or IBM Extension 496 B 6 Legend of Characters C Serial Port Interface BARR RJE conforms to the IBM standard for sending data to and receiving data from the PC asynchronous serial ports COM1 to COM4 You can use the serial port to drive printers or read data from other devices This appendix lists serial port signals and printer cable specifications KAJ Signals for 25 Pin Serial Ports Signals for the 25 pin serial port connector on the PC are as follows Pin Number Name Direction Description 1 PRO GND Protective Chassis Ground 2 TXD out Transmit Data 3 RXD in Receive Data Used for XON XOFF flow control and receive data 4 RTS out Request To Send Always set by BARRIRIJE to 1 5 CTS in Clear To Send Used for flow control If CTS 0 then no data will be sent This line can be jumpered to RTS to force CTS 1 6 DSR
389. is controlled by the computer or serves as memory or a source of information Ex amples of peripheral devices include disk drives printers and communications devices such as modems physical unit PU In SNA communications an independent unit attached to an SDLC line pin One of the conducting contacts of an electrical connector plot output Output from the host to be written to a graphics plotter device port A PC connector for attaching peripheral devices to PCs PR1 RJE printer 1 printer control data Data used to specify the operating mode of the printer printer forms commands Commands sent to the host to manage printing special forms print queue A list of items waiting to print print server A program or processor attached to a LAN that manages file printing 544 Glossary print spooling Managing a queue of files to be printed on one or more printers production disk A disk used in daily PC operation program A set of instructions that gives step by step details for performing a task Computer instructions can be written in a high level language like FORTRAN BASIC or PASCAL Instructions in a form directly usable by the computer are called machine language instructions protocol See communications protocol protocol conversion Translation between two computer proto cols such as ADLC and SDLC so that two dissimilar systems can communicate PU See physical unit PU1 RJE p
390. is set for half duplex DATMODE HALF See Chapter 2 of the Host Definition Guide for more information about DATMODE Sabm Set Sent by BARR RJE X 25 connection to initialize asynchronous the link to the X 25 network Applies only to balanced mode X 25 connections Snre Set normal Host sends Snre instead of Snrm for modulo response 128 sequence numbering See the modulo 128 mode discussion later in this section extended BARR RJE 365 adoag wwo ZZ 22 Comm Scope Table 22 2 SDLC and X 25 Scope Characters continued Characters Description Notes Snrm Set normal response mode Host sends Snrm to remote setting Normal Response Mode Ua Unnumbered Positive response to an SDLC mode setting acknowledgment command such as Snrm Undf Undefined Unrecognized frame received Should never occur Xid Exchange Host sends Xid to request remote identification identification Xidr Exchange Remote sends identification data IDBLK and identification IDNUM which define a switched PU in a response VTAM library Ilegal When this follows a received frame for example Rr the frame is not formatted correctly or is illegal in this mode Should only occur when the program restarts 366 22 2 SDLC Connection Table 22 3 SDLC and X 25 Scope Characters Indicating Errors Character Description Notes A Abort Frame ended with 111111
391. k or tape KB Kilobyte key See hardware key kilobyte A unit of computer memory that is 1024 bytes Each byte is eight bits long 1024 in decimal notation is the same as 10000000000 in binary notation In com puter literature the kilo prefix means times 1024 LAN See local area network language A language consists of a set of symbols the rules that define which sequences of symbols are syntactically correct and the meanings attached to various parts of the language Examples of computer lan guages include FORTRAN C COBOL and ALGOL LAT Local Area Transport an early networking protocol used by DEC DECNET is the newer protocol leased line A communications link provided by the telephone company that is dedicated for use by one customer It is also called a private line service and can be a privately owned cable between two points line Connection between one computing unit and another computing unit such as a 540 Glossary host computer and a remote terminal In this manual line usually refers to a line coming out of a communications con troller that is connected to a modem by an RS232 cable line speed The number of binary digits that can be sent over a communication line in one second Line speed is usually expressed in bits per second bps line trace A recording of the frames sent and received on a communication line that is useful for diagnosing communications problems
392. key to return to the Installation Description screen 272 18 Tuning and Global Options EERE ASCII and EBCDIC Translation Tables On the PC characters are coded in ASCII On an IBM mainframe characters are coded in EBCDIC When files are sent from the PC to the mainframe characters usually are translated from ASCII to EBCDIC depending on the send mode When files are received to the PC from the host computer characters usually are translated from EBCDIC to ASCII depending on the receive mode BARR RJE uses the ASCII and EBCDIC translation tables discussed in this section to translate characters You can change these tables to customize data translation for your application Typically you need to change the data translation only if you change the native language character set or need to process special characters for print applications See Appendix B for a description of the ASCII and EBCDIC character sets and their standard translations Translation Table Restrictions The translation tables do not affect all data processed by the Barr software These restrictions apply mh oo z 5 im gz i 5 a Carriage control characters are not translated by the translation tables These characters are processed separately according to the receive mode you select on the Assign Devices screen Data will not be translated by the translation tables if you select any of these receive modes Binary Fi
393. l screen For more information about the spool header see Appendix E Assign Devices ASCII data with ASA carriage control No OUTPUT statement used in file No Class 1 Spool header from data No Ignore 0 lines from start of file Create separator files No Write spool header to file No Strip spool header No Choice 186 10 9 Options for Assign Devices ASCII data with ASA carriage control Choose whether to convert ASA carriage control to machine carriage control for ASCII files so you can send them to an S 370 channel printer requires Barr PRINT370 hardware and software No Do not convert ASA carriage control Yes Convert ASA carriage control to machine carriage control You must set the receive mode to ASCII Because the file must have a spool header you also must receive it to the print spool or write it to a file and set Write spool header to file to Yes The software inserts a flag in the spool header and performs the conversion when you print the file _ A 2 5 S o D 7 OUTPUT statement used in file You can use the Barr OUTPUT statement to provide information typically used for printing a file such as job name form name file name copies priority and class You insert the information in the file before it is received to the PC Then BARR RJE extracts it from the file stores it in the spool header and displays it on the Print Spool screen The OUT
394. lass for grouping similar files The class value can be a digit or letter The RJE system does not supply the host class value to the remote but you can set it with BARR RJE options listed in Table E 1 or with the Class option on the Assign Devices Options screen FCBNAME fcbname The eight character name of the Forms Control Buffer FCB UCS The eight character name of the UCS print train The UCS name comes from the host SETUPHDR PDIR feature 00000FB5 Spool file reprint offset used internally by the software If printing halts because you put the file on hold or because of a software error condition the software records where it left off The field remains blank until printing halts It resets to blank when printing resumes When you use the reprint feature to resume printing the software uses this value to reposition the file at the correct starting point H TCP banner indicator used internally by the software BARR RJE uses this field if you have the BARR PRINT for TCP IP option and you set up the software to process host banner page requests The print spool automatically adds a beginning banner page when it receives an LPD file But the banner does not print unless the print spool detects a banner page request in the LPD control file When the host does not request a banner for a file this value is set to H to tell the software to strip the banner 510 E 4 Field Descriptions D One character file disposition indic
395. laying Disable channel stop not found error messages Choose whether the software displays error messages if a channel stop in the file is not defined in the form definition No Default Channel stop error messages are not disabled and therefore will display This choice is useful if you want to be alerted when a channel stop is not defined in the carriage control table 286 18 2 Printer Control Yes Channel stop error messages are disabled This choice is useful for jobs for which missing channel stops are acceptable This choice alters the file slightly As ASCII data is received by the Barr software the software inserts one line feed LF each time an undefined channel stop from 2 to C is encountered When a skip to channel 1 is received the software inserts a form feed FF You can use this choice with the Disable form mount error messages option Options for Forms Overlay You can specify a forms overlay directory for each LPT COM or NET destination device on the Miscellaneous Printer Options screen for each device These overlay options affect all of the devices for which an overlay directory is defined See section 8 7 for additional information about using the forms overlay feature Search for form overlay by This option controls the method BARR RJE uses to search the forms overlay directory for overlay files and thus how you must name them You can define both beginning and ending overlay files An overlay
396. le 0 frames received 0 frames discarded 0 times data was lost page 2 next page reset Any key frames sent Number of 802 2 frames sent to the host frames received Number of 802 2 frames received by the Barr PC frames discarded Number of frames lost N oo o Ej 3 9 K Ss an o an times data was lost Number of times a frame was only partially received usually because the frame exceeded the buffer size SAP buffers available Number of Service Access Point receive buffers available Controlled by the LAN Support program Page 3 802 2 Link Statistics gt Press to advance to page 3 BARR RJE 381 an o S a D S a E E oO m N 802 2 Link Statistics 0 frames sent 0 timeouts 0 frames received Partner Address 000000000000 0 frames received with errors 0 frames sent with errors page 3 next page reset Any key frames sent Number of 802 2 frames sent to the host frames received Number of 802 2 frames received by the Barr PC frames received with errors Number of 802 2 frames received with either CRC errors or frames shorter than two bytes indicated by an If on the Communication Scope frames sent with errors Number of times an error was reported requiring BARR RJE to retransmit the frame timeouts Number of times a response was not received within the 802 2 timeout period Partner Address Co
397. le Two are listed below the table in section B 5 Extended ASCII Codes For the ASCII to EBCDIC tables Translate control codes to Control codes allows you to use Extended ASCII codes for 80 FF On the PC keyboard you can display extended ASCII characters by holding and typing the decimal code for the symbol See the ASCII code pages in your DOS manual for a list of ASCII symbols and their decimal codes 2 ea Lu gzj So 2 m 492 B 3 EBCDIC and ASCII Translation EYE AScii to EBCDIC Translation Table A E G A E G A E G A E G A E G A E G A E G A E G S B r S B r S B r S B r S B r S B r S B r S B r c Cc a c Cc a Ce Ge sa CG 2a c Cc a Gr SC va Cy Gy a CoCa I D p I D p I D p I D p I D p I D p I D p I D p I I h T T h II oh f D h I I h I I h I I h I I h C i Come Cri omer 3 CA pat Cs ad c oi CG oa c c c c c c c c 00 00 NUL 20 40 sP 40 C 60 79 80 00 NUL AO 40 SP co 7c EO 79 01 01 SOH 21 5A 41 cl A 61 81 a 81 01 SOH Al 5A cl cl A El 81 a 02 02 sT 22 7F 42 C2 B 62 82 b 82 02 STX a2 7F C2 C2 B E2 82 b 03 03 ETX 23 7B 43 3 c 63 83 c 83 03 ETX A3 7B c3 03 c E3 83 c 04 37 EOT 24 5B 44 C4 D 64 84 d 84 37 EOT A4 5B c4 c4 D E4 84 d 05 2D ENQ 25 6C 45 C5 E 65 85 e 85 2D ENQ A5 6C c5 C5 E E5 85 e 06 2E ACK 26 50 amp 46 C6 F 66 86 f 86 2E ACK A6 50 amp c6 C6 F E6 86 f 07 2F BEL 27 7D 47 C7 G 67 87 g 87 2F BEL A7 7D C7 C7 G E7 87 g 08 16 BS 28 4D 48 C8 H
398. lename for example DATA f Return to the Advanced menu by pressing Esc Note You only need to change the destination to FILE if the file you are creating will be used for diagnostics and you are not currently writing to a file Recreate the problem during the memory dump If the problem involves receiving a file you need to receive the file during the memory dump While the memory dump is on you might see status messages such as CON has begun CON has ended and PR1 has begun N oo o Ej 3 D K Ss an o an After you recreate the problem generate a memory dump as follows a From the Operation screen select Advanced b From the Advanced screen select Diagnostics c From the Diagnostics menu select Memory Dump The Barr software writes memory dump information to the DUMP file in your current directory You can view the DUMP file in the DOS session by using a text editor the more command or the LIST program Note Do not try to print the DUMP file It might be huge and contain unprintable characters BARR RJE 399 If you are not certain your memory dump worked compare your DUMP file to the sample in Figure 23 2 Version 97A3 AX 324D BX 07C9 CX 07C9 DX 0C08 DS 520D ES 5CDC IRM B438 8 4515 SP 0883 BP 08AF SI 0003 DI 0005 F 3212 CS 3882 IP 04F3 SNA_STAT 04F3 Program interrupted by Memory dump OPER CENTRAL HOST NAME 0132344556677001122334456576700121323445566 560
399. lied by 520 Set Normal Response Mode Snrm command 24 Set Vertical Channel SVC command 291 Set Vertical Format SVF values supplied by 520 SETUP MSG 524 See also HASP190 SETUP PDIR 518 Barr option 518 JES2 ESA parameter 518 option 283 See also SETUPHDR SETUPHDR 517 Barr option 518 Edit Forms with 514 515 522 enabling 517 JES2 parameter 518 See also PDIR PSERVIC parameter 518 Share command 321 SHARE EXE utility 39 error message 358 Sharing printers See Printer sharing Shift Function Key Definitions screen 251 252 Single Logical Unit 28 Size See File attributes Skip over perforation 224 SLD 520 SME cable 298 SNA 19 LUs 19 network 15 publications 5 PUs 19 SNA sessions active 802 2 380 Coax 383 SDLC 377 X 25 384 Software name 48 product options 48 374 startup command 47 test 306 update 41 See also Version Software configuration minimum 49 Software files 39 access 44 load 40 Sort command 411 417 Source devices 51 153 alternating between 193 assigning destination to 193 194 descriptions 154 maximum number of 153 selecting 152 Source Queue Options screen 115 Space forward command JES2 469 Spanish character sets 277 Speaker option AT modem 210 Speed line 14 26 print 21 serial port 63 SME cable 298 Spool activity log 355 available space 417 568 Index check for files 130 checklist for setup 122 commands 410 control options 126 directory 124 display options 126 file s
400. line File Format The external FAT file must have a generic comma delimited format compatible with the comma separated value CSV format used by Microsoft Excel You can create the file with a custom application program the Microsoft Excel program a standard program editor or the DOS EDIT utility 144 9 6 Maintain an External FAT File Header Line The first line of the file is a header line Use the header line to align the fields for each entry into columns When you align the fields the table is easier to read and edit The header text is for your use only It does not change the expected order of the fields or affect the function of the table Note If you do not use a header line the file s first line should be blank because the Barr software discards the first line Fields You must include a column for each of the nine possible fields Which fields you use depends on your selection for the Match FAT entries using option The order of the fields in the entry lines is the same regardless of your selection The field order is as follows o im 5 N 2 i D a ir 3 Ej Filename Jobname Formname FCBname In the header line you might want to mark the match criteria to indicate which fields are being used and help distinguish match fields from the override fields as shown in the examples below When you match by Filename Formname you do not use the
401. log console messages about reprint activity Then you can use the log as an audit trail See sections 10 6 10 7 and 21 7 for more information about logging spool console messages BARR RJE 423 Select a File to Reprint To reprint a file you must set the printer state to Reprint and select the file You can select a file if its state is Ready its form is on the printer and its class matches the printer class When these conditions are met the Reprint screen displays The Reprint screen allows you to view or reposition a file before printing resumes Follow these steps to reprint a file Printer File State Form Class Prty Copies Size Units Status LPT1 TAX1040 Printing 1040 1 5 1 284 415 busy LPT2 Ready LABELS 2 0 busy Date Time CHECKS CK501 1 0 af 1998 1 24 97 10 35 PRICES Hold LABELS 2 3 2 4840 1 24 97 10 44 LPT1 TAX1040 Printing 1040 1 5 1 5180 1 24 97 10 35 INVOICES INV99 2 5 8 3262 1 24 97 10 36 Printers Sort t PgUp Help Files Check Spool PgDn Escape Restore 1 Press P to reach the printer attributes T Printer File State Form Class Prty Copies Size Units Status oS gt LPT1 TAX1040 Reprint 1040 1 5 1 284 415 busy 5 LPT2 Ready LABELS 2 0 busy 2 Date Time 7 z CHECKS CK501 1 0 1 1998 1 24 97 10 35 PRICES Hold LABELS 2 3 2 4840 1 24 97 10 44 LPT TAX1040 Printing 1040 1 5 1 5180 1 24 97 10 35 a INVOICES INV99 2 5 8 3262 1 24 97 10 36 Select printer using t
402. logged into a maximum of eight different file servers at one time See Network Connections earlier in this section for a discussion of the available server connections oO o S o 2 9 Ss s m Ss a a Output is routed to the print queue specified by this option Three choices are available name entered above Default Use this choice if all output for this NET device will be directed to only one print queue on a file server as specified in the File server and Print queue fields above FCBNAME FORMNAME Output can be routed to any print queue on any file server by using the FCB name or form name specified in the file The FCB FORM to Print Queue Translation Table displays when you choose either FCB name or form name Use the translation table to associate the FCB name or form name in the file with a file server and print queue The software routes files to the Novell queues you specify in the table entries To include the FCB name and form name information in the file you can use the normal host means of specifying the FCB name and form name usually the SHASP190 message or SETUPHDR record the Barr OUTPUT statement used in file option or the Barr Spool header from data option provides form name only See FCB FORM to Print Queue Translation Table later in this section RJE 3270 If you have RJE 3270 software you can use this method only for RJE data streams not 3270 streams BARR RJE 7
403. logon during full duplex operation your remote is defined to the host as half duplex You must change the remote definition frames received out of sequence Number of SDLC information frames received with the wrong sequence number because a previous information frame probably had a CRC error The out of sequence frames are discarded and the host is asked to retransmit the lost frame N oo o Ej 3 D K Ss N o an checkpoint retransmissions Number of times BARR RJE started retransmission of SDLC information frames because a poll frame sent from the host did not acknowledge all previously sent frames Probably a frame was received by the host with a CRC error Rej retransmissions Number of times BARR RJE started retransmission of SDLC information frames after a Rej frame was received from the host Probably a frame was received by the host with a CRC error Rej is used only in full duplex SDLC BARR RJE 379 Rej frames sent Number of Rej frames sent Rej is sent in full duplex SDLC when an information frame is received out of sequence Rej frames received Number of Rej frames received Rej is sent in full duplex SDLC when an information frame is rejected because it was received out of sequence 802 2 Communications Statistics If you have an 802 2 connection you can view a series of three screens Page 1 802 2 Communications Statistics 0 lines read 0 real buffers in use 0 lines pr
404. luded in the data each time a form feed occurs the counter is reset to 0 Lines per inch Select the number of print lines per vertical inch Choices are 6 and 8 Printer control A two digit hexadecimal index used to send optional printer control data to the printer The index references an entry in the Printer Control Data table defined under Devices and Printers You can use printer control data to select special printer features such as landscape page orientation and proportional character spacing Examples of how to use printer control data with printer forms are provided later in this section The default value 00 means that printer control data is not used Carriage Control Table After you complete the fields on the Edit Forms screen and press Enter the Carriage Control Table screen displays BARR RJE 219 Carriage control stops are used to quickly advance the paper to a specified line rather than moving the paper up one line at a time Stop characters are included in the data from the mainframe computer When a stop character is encountered at the beginning of a data line the paper is advanced to the line indicated in the form definition s Carriage Control Table See Carriage Control Characters later in this section for more information about carriage control stops Specify Control Stops A catriage control stop character can be assigned to any line on the form Valid control characters are 1 to 9 and A to C
405. lve printing structured reports on special paper forms such as checks invoices or tax forms When a file requiring special forms is sent to the printer the data must be formatted to print within the boundaries of the form You can use the Barr Printer Forms feature to define software forms that provide print format information Each form also contains a form name to indicate the type of forms paper that should be used At some sites format information can be provided by the mainframe computer so you do not need to define forms in the Barr software See Appendix F Form Information Sources to determine whether you need to define printer forms in the software When BARR RJE is ready to print a file it loads the format information into the printer You can configure the software to load the form automatically or to load it when a manual command is issued by the PC operator If you plan to use an automatic method for mounting forms see section 18 2 Tuning and Global Options Printer Control for additional settings to make in the Barr software 13 1 Printer Forms Menu If you need to define printer forms in the Barr software use the Printer Forms menu gt From the Installation Description menu select Printer Forms The following menu displays Printer Forms Edit Forms Mount Forms Printer Forms Commands Sent to Host Escape Selection l gt 215 oo mz 53 a 7 i 3
406. ly retain or delete files after they print or are deleted from the spool directory For example you can use individual table entries to set the disposition to Retain for files you want to save and then use the default entry line to set the disposition to Delete for all other files that do not have a matching table entry Retain Files are copied to the retain directory after they print if you use this selection or leave the disposition blank A blank disposition in the FAT entry causes a file to be retained because the software retains all files by default when you specify a retain directory r me 5 N 2 i D a ir 3 Ej Delete Files are deleted after they print Maintain an Internal FAT If you choose to maintain an internal table when you finish with the File Attribute Table FAT Options screen and press the File Attribute Table screen displays File Attribute Table Set file attributes for print spool Filename Form State Class Prty Copies Disposition DEFAULT DEFAULT Enter character The file match criteria and override values you see on this screen depend on your choices for the Match FAT entries using option The table entry fields were described earlier in this section You can make up to 20 table entries If you need more than 20 entries you can request a software option that supports 100 entries or you can use an external FAT file BARR R
407. ly the override values This means that a table Filename without an extension for example DATA can only match a file without an extension and a table Filename with an extension for example DATA 001 can only match a file with an extension If you specify DOS wildcards you can specify file names like DATA or TAX UUN Form If you specify the complete form name in the table it must be an exact match of the file s form name or you can use DOS wildcards in the form name for example STD or CHECKS Jobname If you specify the complete job name in the table it must be an exact match of the file s job name or you can use DOS wildcards in the job name for example DAILY or RPT FCBname If you specify the complete FCB name in the table it must be an exact match of the file s FCB name or you can use DOS wildcards in the FCB name for example 66LPI or LPI Override Values The next fields are file override values Override values are assigned if a matching entry is found in the table The values you specify display on the Print Spool screen for the files they are applied to Specify only those BARR RJE 139 values you want to override and leave blank any values you do not want to change You cannot use DOS wildcards in the override values During print spool operation you can change these attribute values on the Print Spool screen Form You can set or override the file s form name if you use File
408. m connection to central host computer Waiting for LOGON Operation Command to Host Send Files to RD1 Quit Send Files to SCREEN Advanced Mount Forms Selection tlo BARR RJE 329 N o gt J J J as m a D EE Monitoring the Logon Process The word BARR in big block letters indicates that BARR RJE successfully logged on to the mainframe computer You can then monitor the status of your communications session with the Communication Scope Chapter 22 provides more information about the Communication Scope CENTRAL HOST NAME COMMUNICATION SCOPE DRAXid XidrsnrmUaRrRr0 0 23 16 LPT1 0 normal 8 00 21 Operation Command to Host Send Files to RD1 Advanced Quit Send Files to SCREEN Mount Forms Selection l gt When BARR RJE tries to log on to the mainframe error messages display on the console If you receive an error message instead of a logon message review the following common errors and resolutions In this example the LOGMODE is incorrect 2 E S 7 pen c gt cc cc lt co A LU 1 Response Sense Data 08210000010681 VTAM Diagnosis Guide C27 0615 A 15 LU 2 Response Sense Data 08210000010681 VTAM Diagnosis Guide C27 0615 A 15 LU 3 Response Sense Data 08210000010681 VTAM Diagnosis Guide C27 0615 A 15 LU 4 Response Sense Data 08210000010681 VTAM Diagnosis Guide C27 0615 A 15 LU 5 Res
409. m the Operation screen a You are using the JES2 HASP190 message or VSE POWER 1Q40A message to automatically mount forms It is sometimes advisable to mount an initial form for these automatic methods Also the printer commands sent to host are useful Mounting a form causes information from the selected form to be added to the file The form information is stored in a Barr spool header record at the beginning of the file When the file is ready to print BARR RJE converts the spool header to commands and sends them to the printer h oo im 5 Q n 3 a If you use either the manual or automatic means for mounting forms use the Mount Forms option on the Installation Description s Printer Forms menu to mount an initial form The initial form is used each time the software starts Additionally the Mount Forms command displays on the Operation screen so you can change forms during software operation See section 21 6 for more information about mounting forms during software operation Mount Forms Menu You maintain forms from the Mount Forms menu Printer Forms Edit Forms Mount Forms Printer Forms Commands Sent to Host Escape Selection l gt 1 Select Mount Forms from the Printer Forms menu BARR RJE 233 The Mount Forms menu displays a list of the RJE printers you have enabled If two RJE printers are enabled your screen will look similar to the one below
410. me session status and diagnostic messages You can save a log file of console messages to disk See Chapter 10 for more information Initially the console displays the Startup Screen Notes you entered in the BARR RJE configuration The name and phone numbers in the screen example below get replaced by the name and phone numbers of your contacts Chapter 16 describes Startup Screen Notes The next message on the console is the startup message It displays in the center of the console and notifies you about connection progress The specific text of the startup message varies depending on your connection type Different messages display for a PC SYNC or AT autodial modem a dedicated line an external modem with manual dialing and an external modem with dialing via the modem s internal settings Connecting via a PC SYNC or AT Autodial Modem A message in the center of the screen notifies you that the modem is dialing 2 cS sS 72 W gt es mnia cc cc lt i N CENTRAL HOST NAME COMMUNICATION SCOPE D 0 0 LPT1 0 normal 8 00 21 Call 555 1000 for modem connection to central host computer Call 555 4210 for central host operator Call John Smith at 555 2345 for problems with PC Modem autodial in progress Dialing 1 904 555 2222 Waiting for connection Operation Command to Host Send Files to RD1 Advanced Quit Send Files to SCREEN Mount Forms Selection tl 326
411. mes of the print files When a print file is received to the PC BARR RJE obtains the form name from the file and stores it in the spool header When the file is ready to be sent to the printer the software searches the forms overlay directory for an overlay file name that matches the form name Likewise it searches for an optional ending overlay file to send at the end of a file FORMNAME The form name for the file is used as the overlay search name FCBNAME The FCB name for the file is used as the overlay search name FCB UCS The FCB and UCS names usually consisting of four charac ters each are combined to create the search name This method provides more flexibility for loading overlay informa tion It is designed for use with S 370 channel attached printers that get all of their form information from the form overlay file This selection might not work with all available combina tions of the form mounting options The following combination of options works best 1 Enable the SETUPHDR PDIR record at the host computer 2 Set Use Barr FCBLOAD to Yes 3 Set Mount forms by to SETUP PDIR FCBNAME 4 Set Search for form overlay by to FCBtUCS 5 Do not define printer forms in the Edit Forms table The UCS print train name and FCB name are obtained from the host PDIR record 288 18 2 Printer Control UCSNAME The UCS print train name from the host PDIR record is used as the overlay search name UCS FCB The s
412. mmand 414 View Header command 415 VMIRSCS 9 17 operator commands 23 publications 5 VSI RES 9 17 179 180 publications 5 VSE POWER 9 17 1Q40A message 238 284 commands 485 FCBLOAD 521 GO LST command 239 operator commands 23 publications 5 VTAM 16 19 publications 5 VTAM commands 394 link diagnostics 375 W Wait for dial tone option Dataphone 2224B 208 Waiting for Logon message 328 329 Waiting for processes to complete message 313 Waiting to start communication message 295 Warranty 527 530 Wildcard characters See DOS wildcard characters Word processing files sending 453 Work selection criteria 284 285 X X 25 26 communications statistics 383 384 connection message 363 packet level statistics 386 scope characters 365 Xerox Printer Access Facility XPAF 31 option 291 Xerox printers 31 2700 model 104 3700 model 182 4235 model 181 forms with 286 408 515 receive mode for 181 Xid See exchange identification XMS buffers 802 2 381 Coax statistics 383 SDLC statistics 377 X 25 statistics 384 XOFF Status Line 65 XON XOFF 326 XON XOFF flow control bi directional 67 options 64 65 69 support 13 502 XPAF SVC command 291 BARR RJE 571 Z Z file class 148 192 409 507 572 Index
413. mmand menu or twice to return to the Print Spool screen You can use the same method to delete several files at once First mark all the files to be deleted and then press Delete N A m 3 i 3 i 3 S i The Sort command controls the file display order and print order Files are displayed and printed according to the same criteria The Sort command also provides information to help you manage PC disk space It displays the number of files in the spool directory the amount of space used by those files and the amount of available space You can use four sort fields to set the file display and print order Files are sorted by the first field and then subsorted by the remaining three fields By default files are sorted by the sort criteria you specify on the Print Spool Description s Advanced Spool Options screen The default criteria are used each time the software starts BARR RJE 417 You can sort files by their priority class file name size form date and time attributes as described in section 9 4 For example you can print all small files before large files by specifying ascending file size Size gt as the first criteria of the sort order To print large files first specify descending size Size lt Follow these steps to use the Sort command Printers Sort tPgUp Help Exit Files Check Spool PgDn Escape Restore 1 From the Print Spool scree
414. mple 112 See also LAN1 LAN4 messages 354 operating after disconnect 302 LAN Device screen 108 LAN files spooling 433 560 Index LAN protocols 14 LANI LAN4 53 107 108 110 112 153 disable 108 enable 108 See also LAN connections suspend 111 Landscape form 231 overlay file 100 page mode 102 Language for character set 276 Laser printers 12 231 error alarm 59 form feeds 81 LDENS parameter 524 LF Line Feed character 490 Line advancing to new 490 communication 13 dedicated 14 26 28 dial up 26 28 leased 14 printer 12 SDLC connections 324 skip blank 57 skipping blank 58 72 skipping near perforation 224 speed 26 status 323 324 switched 13 Line counter maximum value for 354 Line feed LF character 490 Line printer daemon protocol 83 Line printers control codes 93 timing delay 58 Line spacing 221 See also Lines per inch Line trace 375 buffer size 306 387 console messages 357 enable 387 format 306 388 sample 389 Lines printed display number of 60 73 log number of 356 Lines printed or punched 802 2 380 Coax 383 SDLC 377 X 25 384 Lines read 802 2 380 Coax 382 SDLC 377 X 25 383 Lines received 324 log number of 354 Lines sent 324 log number of 354 Lines per form LPF 93 95 216 351 control codes 95 97 98 Edit Forms 219 FCB 520 spool header 505 509 Lines per inch LPI 93 95 216 351 control codes 95 97 98 102 Edit Forms 219 FCB 520 spool header 505
415. n Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD gt COMMAND CON SCREEN LOG NUL PR1 SPOOL PR2 SUSPEND PU1 SUSPEND SPOOLI1 LPT1 SPOOL2 SUSPEND Select SOURCE DESTINATION Escape Selection t 1 From the Assign Devices screen select the source device for example PR2 Assign Devices DESTINATION FILE SCREEN NUL SUSPEND LPT1 LPT2 COMMAND RD1 SPOOL Selection gt 2 Assign the source device to the destination SPOOL Assign Devices Beginning of file name Ending of file name is jobname New file Log Enter character 3 Specify the file name and options In this example the Beginning of file name is blank and the Ending of file name selection is jobname 174 10 7 Assigning Spool as a Destination Note You do not need to specify the file path because you assigned the spool directory name on the Print Spool Description screen Section 10 5 describes the file name options Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD gt COMMAND CON SCREEN LOG NUL PR1 SPOOL PR2 SPOOL PU1 SUSPEND SPOOL1 LPT1 SPOOL2 SUSPEND Continue Escape Receive mode Options Help _ A 2 5 i S o 7 4 When you press the screen reflects the assignment of PR2 SPOOL Direct Spool Files to Printers Next assign the spool printers to write to PC printers The spool printers route files from the spool directory to th
416. n BARR RJE 211 0 0 disables autoanswer amp D2 means the modem goes on hook and back to command mode when DTR goes off Autodial amp Autoanswer Mode1 ATB0S25 16 amp M1 BO sets the modem to CCITT protocols 25 1 means DTR must remain off at least 10 milliseconds before it is considered off amp M1 means the modem communicates asynchronously in command mode and synchronously when online Note Model and Mode are identical except for amp M and amp Q amp Q is newer but it implements the same function as the older amp M Most modems accept both modes a Fad i E a E v g i i N Autodial amp Autoanswer Mode2 ATB0S25 1 amp Q1 BO sets the modem to CCITT protocols 25 1 means DTR must remain off at least 10 milliseconds before it is considered off amp Q1 means the modem communicates asynchronously in command mode and synchronously when online Note Model and Mode are identical except for amp M and amp Q amp Q is newer but it implements the same function as the older amp M Most modems accept both modes Manual Answer Mode ATBO amp M3 BO sets the modem to CCITT protocols amp M3 means the modem communicates synchronously when DTR is on and asynchronously when DTR is off 212 12 4 AT Modem Options Dial Prep ATDT DT tells the modem to dial the following phone number with tones not pulses Connection Command Sequences This section lists th
417. n select S for the Sort command Sort spool files by Prty gt Date lt Time lt C SPOOL contains 1338881 bytes in 15 files Drive C has 21567488 bytes free Choice 2 Move between sort fields with the 2 key 3 Select an attribute to sort by with the 4 or Q key 4 Set any unused criteria to blank 5 Press when you are done EE Check Spool Command The Check Spool command immediately updates the print spool display with files copied from DOS or a LAN BARR RJE automatically checks the spool directory for new files every 300 seconds or at the time interval you specify on the Print Spool Description s Advanced Spool Options screen o i i 72 i Q N Adding PC and LAN Files to the Print Spool You can use either the DOS copy command or one of these Barr tools to add PC and LAN files to the spool directory Move command PRT utility 418 24 5 Check Spool Command N gt i Using the Check Spool Command i Use the Check Spool command if you cannot wait for the automatic update of the print spool display S Q 2 Printer File State Form Class Prty Copies Size Units Status S gt LPT1 Ready STD 1 415 busy LPT2 Ready STD 2 0 busy Date Time CHECKS CK501 1 0 1 1998 1 24 97 10 35 PRICES Hold LABELS 2 3 2 4840 1 24 97 10 44 TAX1040 1040 1 5 1 5180 1 24 97 10 35 INVOICES INV99 2 5 8 3262 1 24 97 10 36 Pr
418. n a file is received to the PC BARR RJE processes any form or print attribute information included with the file and stores it in a record called a spool header at the beginning of the file BARR RJE uses the information in the spool header when it prints files How the information is used depends on the printer type For ASCII line printers BARR RJE processes the information in the file s spool header and sends header fields such as lines per form lines per inch and carriage control stops as printer commands Usually you do not need to know about the spool header format but if files do not print in the expected format you can examine the information in the spool header to help you pinpoint the problem This appendix describes the information stored in the Barr spool header EA Enabling the Spool Header E2 Spool Header Format You can use any of these features to enable the spool header The spool header is automatically included in files from the host that are written to the SPOOL destination You can include the spool header in files from the host that are written to a FILE destination if you enable the Write spool header to file option on the Assign Devices Options screen m You can include the spool header in LAN files that you submit to the spool with the Barr PRT utility Japeay joods J The spool header consists of several lines of identifier text and data fields Some fields from the spool header such
419. n issue the Send Files command from the Operation screen if you enable at least one SEND device Both SENDI and SEND2 are enabled by default See section 8 9 for more information about these devices LAN4 LAN connection devices automatically move files from a directory on a local area network to another location You can direct files to another LAN location to the mainframe or to a printer from four different LAN directories This option allows users on the network BARR RJE 53 n o 2 E a 3 G a a Fq oa to share the RJE features of a single PC by simply copying files to the designated directory See section 8 10 for instructions to set up these devices NET1 12 send to network NET devices send data from the PC to printers on the local area network Most networks support redirection of LPT1 to LPT3 with device drivers but some networks support redirection of LPT1 to LPT12 On Novell networks you can send files to NetWare print queues On TCP IP networks you can send files to LPR or UNIX print queues You can also send files to device drivers See section 8 5 for instructions to set up these devices NOVELL Queues receive from network Data can be received to the PC from Novell NetWare job queues or print queues You can use up to four Novell queues and direct the received data to PC printers or route it to the mainframe as a job See section 8 11 for instructions to set up these devic
420. n route jobs of a certain type or all jobs with the R command R type J Jnnnn D Ryy where type is the type of output to route nnnn is the number of the job to route and yy is the destination of the routed output For the operand type substitute one of these values PRT to route print output PUN to route punch output ALL to route both print and punch output For the operand Ryy substitute one of these values LOCAL to route the output to the host computer Rnnnn to route the output to another remote specified by nnnn R ALL R Rx D Ry allows jobs routed to remote Rx to print at either Rx or Ry whichever is available first If the operator at remote Ry types this command gt J 3 2 o o 3 3 D 2 z R PRT R Ry D Rx the two remotes share a common print queue The operator can negate this command by typing the following command R type R Rx D Rx This command only affects jobs currently in the queue BARR RJE 475 Examples R PUN J 0234 D LOCAL routes the punch output of job 234 to the host computer R ALL J 7345 D R3 routes all job 345 s output to remote 3 R PRT J 7345 D LOCAL routes job 345 s print output to the host computer R ALL R R2 D R4 allows jobs routed to remote 2 to print at remote 2 or remote 4 R All R R2 D R2 cancels the alternate option R PRT R R1 D R4 routes all jobs originally routed to remote 1 to remote 4 including jobs awaitin
421. n the Operation screen With this choice you must define printer forms in the Barr software to supply printer format information At print time the operator selects the desired form from a displayed list See Chapter 13 Printer Forms for more information about defining forms Power 1040A FORMNAME For the VSE POWER operating system the form name provided by the 1Q40A message is used to automatically mount the form The 1Q40A message is commonly used for BARR 3780 For BARR RJE the SETUP PDIR selection is a better choice 284 18 2 Printer Control With this choice you must define printer forms in the Barr software to supply the printer format information The forms you create in the Edit Forms table must be named for the form name contained in the 1Q40A message See Chapter 13 Printer Forms for more information about defining forms The 1Q40A message is sent to the PC immediately before a job You enable the message in the Job Entry Control Lan guage JECL for each job Specify the form name by using the FNO parameter in the JECL statement LST The job name also is included in the 1Q40A message but it might not be reliable because the host sends the 1Q40A message to the PC only when the form name changes HASP190 FORMNAME HASP190 FCBNAME Depending on your selection the form name or FCB name provided by the JES2 HASP190 message is used to automati cally mount the form These selections are valid only for the MV
422. n the mainframe and interacts with PUs to collect network operation and performance informa tion It includes the functions of the Network Communications Control Facility NCCF Network Logical Data Manager NLDM and Network Problem Determination Application NPDA management products as well as other host based utilities If your host computer supports NetView you can set up your BARR RJE software to use it The software allows NetView program traffic plus the SNA commands Request Maintenance Statistics REQMS and Record Formatted Maintenance Statistics RECFMS See section 18 4 Tuning and Global Options Modem and Line Control for information about 394 23 6 VTAM Commands enabling NetView alerts See your 3270 for RJE manual for information about enabling the NetView Response Time Monitor RTM NetView interacts with remote PUs to collect network operation and performance information These interactions are carried in a special SNA frame called a Network Management Vector Transport NMVT The workstations connected to the mainframe create and process three types of NMVTs a RTMs a Operator alerts application alerts RTM is performed by collecting data from 3270 workstations only when you have RJE 3270 Timers located at each workstation record response times Then the NetView program collects the workstation timer informa tion either periodically or by host operator demand and stores it in a database at the host
423. n you are using the BARR PRINT for LAT BARR PRINT for TCP IP or PRINT TWINAX software options No Default The Barr spool header is not included when the desti nation is FILE Use this option if you will not print the data Yes The spool header is written to all files The header information is used only when you set the receive mode to ASCII 8 370 Channel Transparent or PostScript BARR RJE 191 Strip spool header When you write files to disk choose whether to include the spool header This option displays when you assign the destination SPOOL or FILE for example when you direct PR1 SPOOL SPOOL1 FILE or PR1 FILE The most useful application is to omit the spool header when you direct data from a spool printer to a file for example when you assign SPOOL1 FILE so the print spool uses the header infor mation to route the file via a spool printer SPOOL1 but does not preserve the header in the final destination on disk If you strip the spool header when the file writes to the spool directory for example PR1 SPOOL the file will have no header information and will be assigned class Z 4 2 gt 7 i K This is the only option that lets you remove the spool header for PR1 SPOOL and SPOOL1 gt FILE For PR1 FILE you can use this option or the Write spool header to file option No Default Keep the spool header when you write a file to disk This is the best cho
424. nable Write spool header to file on the Assign Devices Options screen and receive a test file EJ How File Attributes Are Set The values for the spool header fields depend on features you enable in the Barr software Usually you must enable more than one feature to supply all of the fields Blank fields indicate that information was not supplied File attributes can be set with these methods As a host file is received to the print spool Before you copy a PC or LAN file to the print spool From the File Attribute Table FAT as files arrive in the print spool On the Print Spool screen while the file is waiting to print 506 E 3 How File Attributes Are Set When the print spool receives a file from an IBM mainframe it processes attribute information received with the file and stores it in the spool header Usually information from the host SETUPHDR PDIR record is combined with information from a form defined with the Barr Edit Forms feature or information from the host FCB record and HASP190 message is combined See Appendix F Form Information Sources for more information about obtaining form information from the host If you use the BARR PRINT for LAT BARR PRINT for TCP IP or PRINT TWINAX options to receive files from DEC VAX UNIX or AS 400 hosts you can extract attributes from the file s data with software options like Spool header from data and OUTPUT statement used in file See Chapter 10 Assign Devi
425. name Jobname or Filename FCBname as the file match criteria On the Print Spool screen you can use form as part of the criteria that determines on which spool printer the file prints State You can set the file s initial state to Ready or Hold You can set the state to Delete only from the Print Spool screen i o N o a i A a oa Ready Default Files begin printing immediately if their attributes match the criteria of the spool printer Blank also indicates Ready Hold Files cannot print until the operator sets the file state to Ready This choice is useful for files that require the operator to load special forms paper in the printer Class You can specify a number or a letter for the class value On the Print Spool screen you can use class as part of the criteria that determines on which spool printer the file prints Files copied into the spool directory from DOS are automatically assigned a class of Z unless you assign an override value or use the PRT program Prty You can use priority to control the order in which files print Priority values can range from 0 to 9 where 0 is the lowest priority and 9 is the highest Copies Specify the number of copies to print If copies is not specified in the file and the number in the FAT is blank the software assigns a default value of 1 140 9 5 File Attribute Table FAT Disposition Use the disposition attribute to selective
426. ncel job on PR1 on the first line for F1 3 Press to reach the definition entry line 4 Type C PR1 The completed definition looks like this 248 14 2 Entering Key Definitions Alt Function Key Definitions F1 Cancel job on PR1 C PR1 F2 F3 F4 F5 F6 F7 F8 F9 FO Reenter last command Reenters last typed command to host may be edited _ gt T 5 ix 5 A lt a Enter character 5 Press to store the definition 6 When you finish making entries press to return to the Function Keys screen 7 To verify that you stored the new definition select Alt F1 to F10 and review your changes on the Alt Function Key Definitions screen 14 3 Using the Repeat Command Function The Command to Host option on the Operation menu allows you to manually type commands not assigned to function keys When you use Command to Host during program operation you can press to display the last command you typed on the entry line You can then press to re issue the displayed command or you can edit the command before you send it again This feature makes it easy to issue similar commands or correct typing errors You cannot change the function Note If you change the description and command entry lines it does not change the function BARR RJE 249 KEY Defining Function Keys with Replaceable Parameter
427. ncepts Chapter 4 lists product features Chapter 5 describes software and user manual conventions Chapter 6 describes how to load the software files onto your PC Chapters 7 through 18 describe how to configure the software Chapter 19 tells how to save your configuration changes Chapters 20 through 26 describe how to operate the software m Appendixes A through F contain additional reference information you might find helpful during software installation and operation Technical Support Toll free technical support is available for Barr software and hardware products Contact Barr Systems at 800 BARR SYS Monday through Friday between 9 a m and 8 p m Eastern time if you have questions or problems with Barr hardware or software You also can request support via fax e mail or the web site support page For detailed instructions BARR RJE iii about e mail and the web site see the Contacting Barr Systems Electronically booklet For help with LAN or host communications problems contact your PC service consultant or your host communications consultant Before you call Barr Technical Support collect the following information to help the Technical Support staff serve you as quickly and effectively as possible a Serial number Please have your Barr adapter serial number on hand when you call If you request support via a fax e mail or the web site support page include the serial number in your correspondence Y
428. ncludes the logical structure formats protocols and operational se quences for transmitting units through and controlling the configuration and operation of networks software The programmable instructions for operating the physical machinery of a computer system such as programs databases and files Contrasts with hardware components such as the processor printer and disk drive software disk See disk SOH Start of header a character in the binary synchronous communications protocol spool directory The directory where files are queued while they wait for printing or routing from the Barr print spool spool header Data at the start of a file that describes the file and how the file is to be printed spooling Simultaneous Peripheral Operations Online Spooling denotes a system that 546 Glossary allows several independent flows of data to proceed concurrently For example files can be sent from disk to the host computer while other files are being printed See also print spooling SSCP See System Services Control Point standard A set of rules established by an industry or governmental organization Usually implies an extensive review process switched See dial up line SYNC Character sent before a bisynchronous communications protocol message or block synchronous adapter Communications adapter that allows connection to a synchronous modem synchronous communication Mode of commu
429. nd Save Changes and save the installation settings Store the Disk as a Backup After the software files are copied from the disk to the PC store the disk in a safe place The disk serves as a backup copy of the software in case of a PC hard disk failure Access the Installed Files You can use DOS commands to view the installed files To view a list of the installed files use the DOS directory dir command If you installed the files in the default C BARR directory type this command at your DOS prompt dir c barr A list of files and subdirectories displays 44 6 3 Install the Barr Software Files Directory of C BARR lt DIR gt 01 13 97 11 51a oe lt DIR gt 01 13 97 11 51a REF lt DIR gt 01 13 97 11 51a TRAN lt DIR gt 01 13 97 11 51a BARRSNAR EXE 392045 01 13 97 7 33a 5 file s 392045 bytes To view a list of files in a subdirectory specify the subdirectory name For example type this command to list the reference files z N i 2 o 5 an D D i dir c barr ref To access files in a directory use the DOS change directory cd command to change the directory For example type this command to change to the directory that contains the reference files ed barr ref See your DOS manual for more information about accessing files in directories and subdirectories Return to the Installation Description You can return to the Installation D
430. nd a File on SEND2 To send a file only on SEND2 use this command format barrsnar job3 The JOB3 file is sent to the destination device assigned to SEND2 Example 3 Send a File on SEND2 To send a file only on SEND1 use this command format barrsnar job4 The JOB4 file is sent to the destination device assigned to SEND1 346 21 4 Send Files Send Files by Using Function Keys You can use a function key to issue Send Files commands for files you need to send on a regular basis The function key definition must begin with or 2 followed by the file name To send files on SEND1 use To send files on SEND2 use 2 For example suppose you need to send a daily report file DAILY RPT to the host on the SEND1 device You can define the function key combination to send the file as follows daily rpt Note Before you press a function key that contains an embedded send command check the Assign Devices screen to make sure you assigned the correct destination to the SEND device See Chapter 14 for more information about defining function keys Send Files from a LAN Directory You can use the BARR RJE LAN connections feature to automatically send files to the host from a directory on the LAN First you need to set up the LAN connections feature as described in section 8 10 and make device assignments LAN1 RD1 as described in Chapter 10 Then users on the LAN can copy files to the directory When BARR RJE is o
431. nd data com munications begin Characters on the Communication Scope reflect activity between the PC and the mainframe Coax Scope Characters Table 22 5 lists Communication Scope characters for Coax connections BARR RJE 371 Table 22 5 Coax Scope Characters Characters Description Notes nnn Online LU nnn is online to the host nnn Offline LU nnn is offline to the host 0 7 Information frame Frame number of the information frame B Bind Requests communications controller to read a BIND or UNBIND response via a synchronous write Coax Coax protocol Link level protocol being used E Error Condition error received from communi condition cations controller I Initialization Adapter loaded with microcode and complete initialized Porn Power on reset Power on reset for port n sent to com munications controller Pornr Power on reset Power on reset from port n acknowl response edged by communications controller T Timeout No commands received from communi cations controller in the last second 22 Comm Scope Coax Examples CoaxIPor0 baa 002 003 004Mom1 Az Normal communication scope sequence CoaxIPor0 Feat 002 003 004 EP RD LUs are rejected Check your controller setup 372 22 4 Coax Connection Communications Diagnostics BARR RJE has several built in diagnostic tools Some diagnostic programs help you trouble shoot communications problems or diagnose ot
432. nd is used when the file is sent to the printer If you use the Barr print spool you might want to set Mount forms by to HASP190 FCBNAME to obtain the form name or FCB name a i A i o FCBLOAD halve Choose whether to divide FCB records in half if they contain more than 128 characters No Default Long FCB records are not divided Use this selection if FCBs have a maximum length of 128 characters With this choice BARR RJE expects one page of FCB information Yes Divide FCBs in half if they are longer than 128 characters With this choice BARR RJE assumes that each FCB consists of two pages This choice is useful when the printer does not support FCBs longer than 128 and is valid only if the previous option Use Barr FCBLOAD is set to Yes 282 18 2 Printer Control Mount forms by The printer uses printer forms to format the print data If you are using forms for your print application choose which method the software will use to obtain form information for a file This process is commonly referred to as loading or mounting forms As a file is being received form information is stored in a Barr spool header record at the beginning of the file When a file is ready to print BARR RJE converts the spool header to commands and sends them to the printer ahead of the file The Operation screen choice is the only manual way to load forms The other choices are ways to automatically load form
433. nd requests another copy of the output currently printing or punching It does not terminate the activity in progress If another output device is available the copy begins printing or punching concurrently If only one device is available the copy prints or punches after the current activity completes Only the SYSOUT datasets that match the current output setup class forms and so forth will be duplicated Operators can use this command 472 A 1 JES2 Remote Commands to make copies of special forms output for example mailing labels without duplicating all the job output or rerunning the job Format Enter the N command as follows N dev where dev is the device Examples N PR1 places a copy of the output currently printing on printer 1 in the print queue to create duplicate output N PU2 places a copy of the output currently being punched on punch 2 into the punch queue to create a duplicate deck O Release The 0 command releases the output of a job under the operator s jurisdiction from hold Format Operators can specify a job name or number with the 0 command 0 jobname where jobname is the name of the job output to release from hold D gt ps a 3 2 GC o 3 3 D Ss 2 7 0 Jnnnn where nnnn can be a single job number to release that job s output or a range of job numbers to release a series of jobs output from hold Examples 0 MYJOB releases the outp
434. ndicates a problem in the cable modem or both Check for the following conditions m Is the modem set to AL mode _ N 53 o 3 J oO 2 an e a Is the modem cable connected correctly If any phase of the test fails correct the problem reported by the phase that failed and repeat the test BARR RJE 269 Notes Z N cE 5 amp c a 5 boa z 270 17 2 Perform Loopback Test Chapter 18 Tuning and Global Options The default values for the Tuning and Global Options work for many users If you have sophisticated applications or are experiencing problems review this chapter to learn about the available tuning options Tuning and Global Options Menu gt To reach the tuning options from the Installation Description menu select Tuning and Global Options The following menu displays Tuning and Global Options ASCII and EBCDIC Translation Tables Printer Control Reader Control Modem and Line Control Restart Actions aby oo 4 z im kzi i gt a Trace and Memory Options Display and Disk Options Session and Security Options Miscellaneous Options Escape Selection l gt A brief description of each menu choice is given below Detailed descriptions for each submenu are presented in separate sections of this chapter ASCII and EBCDIC Translation Tables Customize the A
435. nds multiple files and receives output When data transmission is complete the software hangs up the telephone and exits Your application program can then proceed to the next level of operation BARR RJE 25 an gt 2 ras wi gt es n cc cc lt a Dynamic Device Assignment A device assignment mechanism controls the flow of files through the PC Devices can be sources or destinations of files You can specify and direct these sources and destinations from the BARR RJE Assign Devices screen see the Assign Devices chapter PC to PC File Transfer With BARR RJE you can send data from PC to PC by designating one PC as the host and the other as the remote EEJ Communications Features BARR RJE transmits data at high speeds on dial up and dedicated lines BARR RJE can simultaneously send and receive data and perform data translations and conversions On screen statistics provide information about the current communications status Multi Tasking Operating System With the Barr multi tasking operating system these tasks can operate concurrently Entering commands Receiving console messages from the host Printing on several printers Reading from disk Reading from a serial port Sending or receiving data on the synchronous communications line SDLC and X 25 Line Speed to 2 048 Megabits Per Second BARR RJE SDLC or X 25 versions communicate via an RS232 V 35 or X 21 adapter conne
436. nds the commands to drain and restart the printer In this example it sends the JES2 commands P and E 2 Load the forms paper and ready the printer a Load your paper form on the printer Position the top of the form directly under the print head N A o gt a J gt av amp m i 3 2 5 b You might need to manually set the printer lines per form and lines per inch with thumb wheels or buttons c When you are done make sure the printer is ready or online BARR RJE 351 3 Notify BARR RJE that the form is mounted P PR1 E PR1 Mount paper on PR1 using form STD then press any key Any key gt Finally press any key to notify BARR RJE that the paper form is mounted P PR1 15 19 36 E PR1 15 19 36 P PR1 15 19 36 E PR1 15 19 36 T PR1 F STD 15 319 39 S PR1 15 19 40 T PR1 F STD 15 19 40 S PR1 15 19 40 Operation Command to Host Send Files to RD1 Advanced Quit Send Files to SCREEN Mount Forms Selection l gt BARR RJE automatically sends the Mount Forms and Start Printer commands In this example BARR RJE sends the JES2 commands T E and 8 i o a i Wu c gt s c co rr N Console Messages Messages on the console help you monitor BARR RJE activity You can record most of these messages in a log file if you assign LOG FILE on the Assign Devices screen Barr console
437. need to enter it each time you issue a command When you use the Command to Host option from the Operation menu the software automatically adds the specified character to the beginning of each command you issue with function keys or manually from the command edit line Disable console commands This option allows you to disable manual command entry from the Command to Host edit line No Default Operators can compose commands to the host on the Command to Host edit line Yes Disables console commands Operators cannot enter commands on the Command to Host edit line They can only issue commands defined for function keys This feature prevents the PC operator from sending unauthorized or undesirable commands You can use this selection with the option Disable Installation Description under Tuning and Global Options Session and Security Options to prevent the operator from modifying function key definitions or using Command to Host Note If you include prompts in your function key definitions operators can enter commands to the host even when you disable console commands When operators press a function key defined with a prompt the Command to Host edit line displays Instead of responding to the prompt the operator can backspace over the command and enter a command from scratch If you want to eliminate this possibility do not include prompts in your function key definitions 256 14 6 Options Commands Sent at Sta
438. need to manually dial the phone number follow these steps 1 Turn on the modem Press the Talk button or set the switch to Talk Dial the host computer s phone number 2 E S 7 wu cc eg cc cc lt A Wait for the computer to answer Listen for the high pitched data tone Oy E S ot Press the Data or Normal button or set the switch to Data or Normal 7 Place the telephone receiver in the communications cradle or set the receiver aside until you disconnect it After you connect the Waiting for Logon message displays 328 20 2 Monitoring the Connection Process CENTRAL HOST NAME COMMUNICATION SCOPE 0 0 LPT1 0 normal 8 00 21 Call 555 4210 for central host operator Call John Smith at 555 2345 for problems with PC Call 555 1000 for modem connection to central host computer Waiting for LOGON Operation Command to Host Send Files to RD1 Quit Send Files to SCREEN Advanced Mount Forms Selection tl7 Connecting via an External Modem with Modem Dial If you use an external modem and dial the phone number with the modem s internal settings the Waiting for Logon message displays while BARR RJE waits for the modem to make a connection CENTRAL HOST NAME COMMUNICATION SCOPE 0 0 LPT1 0 normal 8 00 21 Call 555 4210 for central host operator Call John Smith at 555 2345 for problems with PC Call 555 1000 for mode
439. nes per inch After you print the file to determine why a file did not print as expected Because the spool header is not part of the printable text you must view it separately from the file text The View Header command displays the spool header exactly as it appears in the file The header includes any changes you made to it from the FAT or Print Spool screen Note The View Header command displays only the first 132 lines of carriage control information from the spool header N A mz 3 N g o So 3 D S Follow these steps to view the header 1 Select H to view the spool header for the selected file The text of the spool header displays on the screen BARR RJE 415 Spool Header File PAYROLL 003 PRINTER FORMNAME BOND LPF 066 PLPF 066 LPI 6 CONTROL 00 LOCNAME JOBNAME jobname COPIES 00000001 PRIORITY 2 STATE READY CLASS 1 FCBNAME fcbname UCS D Carriage Control Table 000000000111111111122222222223333333333444444444455555555556666666 123456789012345678901234567890123456789012345678901234567890123456 1 For a detailed description of the spool header fields see Appendix E 2 Press once to return to the Files command menu or twice to return to the Print Spool screen Change Attributes for One File You can use the Files command to change the state class priority and copies attributes for a file 1 Select a file by using the keys A blinking
440. nfiguration File Settings to Program File You can save settings stored in the configuration file to the program file by loading the configuration settings into the Installation Description and then saving your changes to the program file Follow these steps 1 Specify the installation startup command including the configuration file name For example barrsnar i daily cfg 318 19 4 Using Configuration Files 2 Select Exit and Save Changes from the Installation Description menu The default for Save Changes to C BARR BARRSNAR EXE file is Yes so press Enter The software writes the configura tion settings to the BARRSNAR EXE program file BARS pue XZ 6L BARR RJE 319 19 Exit and Save Notes 320 19 4 Using Configuration Files Chapter PAI BARR RJE Startup After you install and configure the BARR RJE software you can start BARR RJE At startup BARR RJE first connects with and then logs on to the host The BARR RJE Operation screen allows you to monitor the connection and logon process You must complete this startup process each time you use BARR RJE E R Starting BARR RJE You can start BARR RJE one of these ways From the BARR RJE Installation Description screen From the DOS prompt a When you power on the PC With different configuration files for different host sites From an application program N w gt J J J m a D The examples in thi
441. nfiguration requires more than 100 000 bytes of conventional memory buffers specified with the Memory allocated for buffers option For example if you drive several printers simultaneously or use the BARR TAPE software option you might need to allocate extended memory Extended memory also is useful if there is not enough conventional memory available to use the DOS session The default extended memory buffer amount is 0 Increase this amount as needed When you increase Extended memory allocated for buffers you usually must decrease the value for Memory 304 18 6 Trace and Memory Options allocated for buffers to free sufficient conventional memory for the DOS session Other software features can use extended memory buffers but the DOS session requires conventional memory Start by setting Extended memory allocated for buffers equal to the original value for Memory allocated for buffers and then gradually decrease Memory allocated for buffers Test that the software still operates after each decrease Conventional memory Memory allocated for buffers is measured in bytes while extended memory allocated for buffers is measured in Kbytes KB or increments of 1 000 bytes Because extended memory buffers use some conventional memory buffers as overhead the total increase in extended memory buffers should be greater than the total decrease in conventional memory buffers However the value for extended memory buffers does not need
442. nframe It controls communication between the mainframe application software and remote workstations 18 3 3 Communications Networks NCP The mainframe connects to one or more IBM front end processors FEPs that is the 3704 3705 3725 or 3745 These communications processors manage communications links and connect to one or more remote terminals NCP resides in each processor and controls its operation ow lt i a 2 m 5 i 3 o 5 FEZ3 SNA Physical and Logical Units PUs LUs SNA defines the entities in the communications network The main communications entity visible to the end user is the physical unit PU which is subdivided into logical units LUs The PU corresponds to the physical connection to the host LUs correspond to application sessions available through each PU connection The most common PUs are the IBM 3174 and 3274 control units and the RJE workstation Each physical connection to the host must have a separate PU definition in VTAM Each LU is an independent entity within the parent PU Separate LUs represent each of the 3270 sessions terminals or printers and RJE sessions printers punches readers console and commands To distinguish the LUs in each PU each LU has a unique number known as the LU s local address LOCADDR Local addresses can range from 1 to 255 When data flows between an LU and the host it includes the LU s local address EFJ Host P
443. ng PU1 FILE In most cases the mainframe output needs only a Beginning of file name In this example output from host punch 1 PU1 is assigned to a file named ACCOUNTS 1 From the Assign Devices screen select PU1 as the data source 2 Select FILE as the destination The file name screen displays BARR RJE 169 4 2 gt 7 i K Assign Devices Beginning of file name C ACCOUNTS Ending of file name is not used New File Log Enter character 3 Enter C ACCOUNTS as the Beginning of file name 4 For Ending of file name select not used 5 Use the default options New File and Log When you press Enter the Assign Devices screen displays the file name in parentheses after the source name Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PU1 C ACCOUNTS SPOOL1 LPT1 Continue Escape Receive mode Options Help With this assignment a All files received to the PC from PU1 will be written to the directory C and will have ACCOUNTS as their file name Because no extension was assigned to the file name and the New File option was used the software automatically generates three digit extensions as described under File Name Extensions The first file received will be named ACCOUNTS 001 the second will be named ACCOUNTS 002 and so on Because the Log option was used messages are written to the
444. ng and Global Options Trace and Memory Options screen set Test mode to Yes In test mode RD1 is sent to PR1 and RD2 returns on PR2 If you assign PR2 to the SCREEN the input from the serial port appears on your screen a i S 2 Z lt 5 o o Z pej N 452 26 1 Converting Data for Serial Port Input EFA Transferring Files from PC to PC A PC with BARR RJE can send exact copies of files to another PC that uses BARR RJE You can transfer various types of files including Lotus files word processing files and program files in EXE and COM format You can connect by PC to PC dial up or through the JES network File Transfer by Dial Up Connection A PC can transfer files to another PC through a dial up connection You should configure one PC as Host and the other as Remote See section 18 4 Tuning and Global Options Modem and Line Control Configure BARR RJE From the BARR RJE Operation screen on both PCs 1 Select Advanced 2 Select Assign Devices 3 Select PR1 as the source device 4 Select FILE as the destination to assign PR1 to disk 5 Type the name of the directory followed by a backslash in the Beginning of filename field nN Select Receive mode 7 Select Transfer files 8 Press twice to return to the Operation screen N o i D 2 2 gt kZ S 7 Connect by Telephone BARR RJE must be running on both PC 1 and PC 2 Follow these s
445. nication in which blocks of characters are sent as a unit without start and stop bits for each character Unlike asynchronous communication the timing for data is obtained from the car rier signal and is not a function of the time from the start bit System Services Control Point SSCP In SNA communications a focal point within an SNA network for managing session services for end users of the net work SSCP includes configuring coordi nating network operator and problem determination requests and providing directory support tab character A character that causes the printer to advance to a tab stop TCP IP Transmission Control Protocol Internet Protocol A suite of protocols designed to allow communication between networks regardless of the technologies implemen ted in each network terminal The end of a communication line A sim ple terminal is a keyboard and a TV like display More powerful terminals include disk storage a computer printers and plotters timeout An elapsed time period without a transmission or other expected event occurring token ring interface coupler TIC An interface adapter installed in the 3745 or 3725 to connect to a token ring network token ring network High speed communication network that consists of physical equipment and archi tecture This is the IBM architecture for LANs The network is characterized by ring structure with a single token continu ously circling the ring
446. nly when the form name changes formname The form name stored in the spool header is used as the file name BARR RJE 163 formname j obname jobname formname Both the form name and job name are included in the file name The first value becomes part of the file path and allows you to group files The second value is the file name If you select formname jobname for example the form name is included in the file path and the job name is used as the file name See Example 2 later in this section Note The job name from the HASP190 message might be an unreliable because the host generates the message only when a the form name changes k 3 fcbname e The FCB name stored in the spool header is used as the file name Note The FCB name information from the HASP190 message might be unreliable because the host generates the message only when the form name changes source filename When you assign SENDn FILE SENDn SPOOL SPOOLn FILE or LAN SPOOL you can use this option to preserve the original file name Specify the destination file path under Beginning of file name not used Only the Beginning of file name is used The Beginning of file name must include the full path and file name Select not used when you direct data to device drivers See Example 3 later in this section from file The file name is obtained from a text line within the file When you select this option and press Enter you are
447. ns Printer Control screen For more information about forms overlay see section 8 7 8 6 Choose Printer Type You must assign a printer type for each LPT COM and NET device you use 1 From the Devices and Printers menu for the selected device select Choose printer type A list of printer types displays 92 8 6 Choose Printer Type Choose Printer Type LPT1 printer type DAVFU Dataproducts Generic Printer is not listed below User must manually set lines per form ANSI DEC compatible NCR 6430 Fujitsu RS232 o C Itoh CI300 CI600 OKIDATA 92 93 g DAVFU Dataproducts OKIDATA 2410 2350 D P I OKIDATA 2410 IBM compatible 2 EPSON IBM Proprinter 6262 A Printronix P300 P600 5 Florida Data 120 130 Printronix P300 P600 with IGP Genicom 4410 4440 Printronix P6000 0 Genicom 1255 Linewriter Sand Fujitsu M304X Hitachi FP1500 Hewlett Packard 256X STC D P I T Linewriter RS232 Genicom D P I no LPI ov Selection l gt 2 Select the printer type Except for the special selection Generic all of the printers on this screen are line printers For most selections the Barr software automatically sets lines per form and lines per inch on the printer so you do not have to adjust these settings manually See Lines per form and Lines per inch later in this section for a description of the settings provided by the Barr software The printer type selections fall i
448. nslate control codes to Question marks converts all control codes embedded in the data to question marks In the Barr software entries 00 to 1F and 80 to 9F of the ASCII to EBCDIC table and entries 00 to 3F of the EBCDIC to ASCII table are altered if you select this option ob oo im gz i gt an Select Translate control codes to Question marks before you use the Edit translation tables option A message indicating your selection displays on the lower half of the screen The translation tables have been modified to translate control codes to question marks You can select Edit translation tables to see these changes or to make additional changes See section 18 3 Reader Control for additional options that affect the ASCII to EBCDIC translation of 89 8A 8C 8D 9A FF and 7F Choose Language for translation tables Modify the ASCII to EBCDIC and EBCDIC to ASCII translation tables for use with native language character sets as described later in this section BARR RJE 275 Edit translation tables Manually modify entries in the ASCII to EBCDIC and EBCDIC to ASCII translation tables as described later in this section Assign translation tables to devices Choose which of the two EBCDIC to ASCII translation tables will be used for data received on each RJE print or punch stream This feature is described later in this section Choose Language for Translation Tables You can modify th
449. nslation tables it could override your edits RJE 3270 If you have RJE 3270 four tables are available two different ASCII to EBCDIC tables and two different EBCDIC to ASCII tables The software uses ASCII to EBCDIC Table One when you send data to the host using a reader device RD1 to RD4 The software uses EBCDIC to ASCII Table One when you receive data on an RJE print stream PR1 to PR7 an RJE punch stream PU1 to PU4 or a 3270 print stream PR_1 to PR_4 The software uses ASCII to EBCDIC Table Two and EBCDIC to ASCII Table Two for 3270 display terminal emulation or 3270 printer emulation a i A i o Accessing the Translation Tables Follow these steps to access the translation tables 1 Select Edit translation tables The ASCII to EBCDIC translation table displays 278 18 1 ASCII and EBCDIC Translation Tables 006F 106F 2040 30F0 407C 016F 116F 215A 31F1 41C1 026F 126F 227F 32F2 42C2 036F 136F 237B 33F3 43C3 O46F 146F 245B 34F4 44C4 O56F 156F 256C 35F5 45C5 066F 166F 2650 36F6 46C6 076F 176F 277D 37F7 47C7 O86F 186F 284D 38F8 48C8 096F 196F 295D 39F9 49C9 0A6F 1A6F 2A5C 3A7A 4AD1 OB6F 1B6F 2B4E 3B5E 4BD2 OC6F 1C6F 2C6B 3C4C 4CD3 OD6F 1D6F 2D60 3D7E 4DD4 OE6F 1E6F 2E4B 3E6E 4ED5 OF6F 1F6F 2F61 3F6F 4FD6 ASCII to EBCDIC 50D7 51D8 52D9 53E2 54E3 55E4 56E5 57E6 58E7 59E8 5AE9 5BAD 5CE0 5DBD 5E5F 5F6D 6079 6181 6282 6383 6484 6585 6686 678
450. nstallation menu displays BARR Systems Inc Installation Software INSTALL FILE DESCRIPTION Y N DESTINATION BARR RJE Program Files Y C BARR BARR Reference Files Y C BARR REF BARR TRAN Reference Files Y C BARR TRAN Use arrow keys or TAB to highlight fields you wish to edit F10 to accept all fields and proceed ESC to Exit Use the arrow keys or to move around the menu a Choose which files to install Type Y to install a file or N to skip it b Enter the destination path including the drive letter and directory names where you would like to install the software The installation program creates the directories if they do not already exist The 42 6 3 Install the Barr Software Files default path for the Barr software is C BARR Other files are stored in subdirectories of this path c Press when you are done The screen displays these messages to indicate installation progress Creating Directories Installing Software z N i o o 5 an e D 5D i As the files are expanded from the software disk to the destination directories these messages display Exploding Unshrinking 5 Choose whether to configure the software After the software files are copied the following screen displays Copy of software is complete Ready to load software When software is loaded you will need to Step 1 Enter configuration information Step 2 S
451. nstructions Printer Forms Function Keys Commands Sent at Startup Startup Screen Notes Interrupt Request Address and Loopback Test Tuning and Global Options Exit and Save Changes Selection l gt 2 Select Interrupt Request Address and Loopback Test 261 Interrupt Request Address and Loopback Test Interrupt request IRQ2 Address 280 DMA request 1 Perform loopback test No Choice Hardware Conflicts Change the Interrupt request Address and DMA request default settings only if you verify a conflict with other equipment in the PC If a hardware conflict exists the software will not function correctly when you try to start or operate it Interrupt request Hardware line over which the processor and adapter communicate The IRQ carries signals to get the processor s attention when the adapter is ready to receive or send information The default setting for the SYNC ISA adapter is IRQ2 You might find an IRQ conflict if you use a LAN adapter because LANs typically use IRQ2 If you verify an IRQ conflict change the software setting Other choices are IRQ5 IRQ10 IRQ11 IRQ12 and IRQ15 z N 5 amp c a 5 paa S a Address Address for the device Note The address in the software must match the address jumper setting on the adapter The default value on the SYNC ISA adapter and in the software is 280 If
452. nt Spool session This session displays the Print Spool screen Use this session to control file printing Chapter 24 describes print spool operation Chapter 9 describes print spool setup N _ o gt eoj ps J amp m i 3 2 5 Keys to Switch Sessions You can use these keys to switch sessions Alt Spacebar Move to the next session At X Return to the last active session Ait O Move to the Operation session At 0 Move to the DOS session At P Move to the Print Spool session Note The default hot key combination is Ctrl Alt You can change the hot key combination from the Installation Description See section 18 8 for more information BARR RJE 349 Use the Sessions Menu to Switch Sessions You can use the Sessions menu to move from session to session Advanced Assign Devices Diagnostics Sessions Escape Selection tl 1 From the Advanced menu select Sessions You can go directly to another session by pressing Ctrl Alt session On next screen the session is the first character of session name Any key 2 Press any key to display session choices Select gt OPER DOS PRINT 3 Use the arrow keys to select a session Diagnostics BARR RJE diagnostics help you resolve communications problems Chapter 23 describes the diagnostic tools AK Mount Forms If you define printer fo
453. nter is currently printing it will continue printing to the end of the file before stopping A printer that is drained requires a start command to become active again S PR1 The command starts the RJE printer If the printer was drained using a P command the start command enables it to become active again A job waiting for processing will print if its form name SYSOUT class and other selection criteria match the criteria for the RJE printer DU PR1 The DU command displays the status of the RJE printer and shows which form is associated with the printer T PR1 F ffffffff The T command sets the form name for the RJE printer If you issue the command manually substitute the actual form name for ffffffff If a form name is specified for the printer only jobs with a matching form name will print The printer must be inactive for this command to be accepted Use the P command to drain the printer before issuing the T command 242 13 5 Printer Forms Commands Sent to Host I PR1 The I command interrupts the job currently being printed The I command stops the RJE printer if the printer is in a draining state DF The DF command displays a list of all output for the remote You can see the job number and the form name of all output files E PR1 The E command restarts the job on the RJE printer at the beginning of the file T Jnnnn P 1 I PR1 The first command T Jnnnn P 1 increases the priority of jo
454. nter type 92 COM device 62 DAVFU 94 DPI 94 95 generic 93 94 Genicom 95 LPT device 55 NET device 75 77 Printronix 94 PRINTER TST file 501 503 Printers command 411 412 Printing checks 223 printer state 406 resolve problems 56 71 505 start before end of file received 128 Printronix printers 93 94 control codes 98 BARR RJE 565 Priority decrease NET device 90 file attribute 409 See also File attributes gateway pooling 300 OUTPUT statement 187 spool header 510 Problem number iv Protocol LPD 83 native TCP IP 83 Protocol conversion 29 PRT utility 433 commands 445 control files 434 441 error message 441 retain directory 436 spool control options 435 version number 445 PRT EXE file 433 PRTMENU EXE file 433 Prty See File attributes PS 2 VGA adapter 308 PU 19 PU1 PU4 153 155 Punch See RJE punches Punch control JES2 459 Punch file deleting first two lines 192 Purge command JES2 474 Q QEMM386 memory manager 304 QMS Lasergraphix 194 Question mark convert control code to 275 function keys with 250 256 printer forms command with 239 translate control code to 491 Queue See Network print queue Queue overflow 367 Queue Server Options screen 116 Quit screen 337 R RD1 RD4 153 159 Reader 11 159 line length 293 maximum length 343 Reader Control 292 screen 292 Ready file status 408 printer state 406 Ready Files command 130 411 413 Real buffers in use 802 2 380 Coax 383 SDLC
455. nterface is the preferable 2 2 RJE Workstations way to connect high speed printers to the PC The printer must be within 20 feet of the PC DOS names for parallel ports are LPT1 LPT2 and LPT3 sjdaqu09 aru Z Serial Ports The serial port transfers all eight bits of a byte sequentially A single wire sends the data from the PC to the printer one bit at a time Another wire sends responses from the printer to the PC Printers with a serial interface use the RS232 standard This asynchronous serial convention supports longer cable distances usually up to 50 feet which allows you to place the printer farther away from the PC The serial port supports the XON XOFF and DTR Data Terminal Ready flow control mechanisms Appendix C describes the serial port interface DOS names for serial ports are COM1 COM2 COM3 and COM4 EEJ Communication Links and Modems The communication link is the type of physical connection between the remote workstation and host computer You can communicate with the host these ways Through a modem for the SDLC X 25 or gateway ADLC communication links Through a direct connection to a communications controller with a synchronous modem eliminator SME for SDLC Through the LAN for the 802 2 or gateway LAN communication links Through a direct connection to a communications controller with the Coax communication link Communication Links BARR RJE works equally well when you connect to
456. ntiguous vector of bits that is read or written as a unit A block can include one or more records Blocks usually have a fixed size block size BLKSIZE The number of data elements in a block A measure of the size of a block usually specified in units such as records words or characters boot To prepare a computer for use by loading the operating system Usually the operating system loads automatically when you power on the computer See also bootstrap bootstrap At startup of a computer system the first record read from disk contains a program used to read the rest of the operating system into memory The first record read is called the bootstrap program bps Bits per second A unit of measure for the rate that information is transferred BSC Binary synchronous communication buffer An area of computer memory used for performing input or output operations 534 Glossary The software reads data into a buffer or writes data from a buffer byte A string of bits that treated as a unit represent a character Usually eight adjacent bits represent one character card Eighty consecutive characters of information or one line carriage control Characters used to control vertical spacing of print lines central host computer See host computer Centronics Printer Interface A common parallel interface for printers developed by Centronics Corporation CGA Color Graphics Adapter a type of video a
457. nting or punching The job resumes output according to job priority The output automatically backspaces one page or card to prevent data loss The I command allows the operator to interrupt a large job and print smaller jobs of higher priority When the small jobs complete the operator can resume printing the large job Format Enter the I command as follows I dev where dev is the device to interrupt Example I PR1 interrupts the job currently printing on printer 1 and re queues the rest of the job for later printing BARR RJE 471 D gt J 3 2 D o 3 3 D Ss 2 7 CA S 2 D c lt x To print a short job with a priority lower than or equal to the job currently printing follow these steps 1 Hold the job currently printing 2 Interrupt the printer 3 Start the short job and then release the job on hold L List The L command displays output attributes for a job including form name FCB name and class Operators can use this command to print applications requiring special forms Format Enter the L command as follows L Jnnnn ALL where Jnnnn is the job name Operators can only specify one job name with this command The ALL operand displays all attributes Examples D J1 32767 displays a list of queued jobs so the operator can obtain the job number see D L J1845 ALL displays the attributes for job 1845 N Repeat The N comma
458. nto three categories m Laser printers Generic for which the software does not provide the lines per form and lines per inch settings Line printers for which the software sends lines per form and lines per inch control codes Line printers for which the software sends lines per form and lines per inch control codes and implements Vertical Forms Unit VFU If your line printer is not listed on the screen check Table 8 1 under Lines per form and Lines per inch for a compatible selection Compare the control codes in the table to the control codes listed in your printer manual to determine if one of the selections will work BARR RJE 93 Printer Types with Special Requirements Some printer type selections have specific requirements as described in this section Generic Use this selection for the following Laser printers Line printers only if you want to use settings other than the ones supplied by the software n o 2 E a 3 G a a Fq oa You need to set lines per form and lines per inch by using either BARR RJE settings printer control data forms overlay or printer forms or manual settings on the printer This selection also is useful if you do not want BARR RJE to change the data To prevent the data from being modified you also must set Printer performance optimized to No under Miscella neous Printer Options DAVFU Dataproducts Printronix P300 P600 W
459. ntries is updated on the bottom right corner of the screen The table size is 1 167 bytes allowing it to hold 20 to 30 entries If you need a larger table you can request a special version of the software from Barr Systems n o 2 E a 3 G a a Fq oa To move between fields within a table entry use the or keys Press to save the current entry and advance to the next entry To remove an entry use the to blank it out Press to exit the table when you are done Translation Table Entries Table entries include these fields Name Specify the FCB name or form name that is included in the source file FCB name or form name can be supplied by the host computer if you enable the host HASP190 SETUP MSG or SETUPHDR PDIR options Or the software can provide the desired value if you use the Barr OUTPUT statement used in file option Note You cannot use DOS wildcards in the entries for this table File Server Print Queue Enter the name of file server and print queue where jobs with the specified FCB name or form name will be routed Error Handling You have two choices for handling any errors that might occur when table entries are used to route print files For example an error occurs if the FCB name or form name from a file is not listed in the table amp 8 8 5 NET1 NET12 Devices The output can be directed to a default printer For this method enter a default value
460. ntrol code examples The control codes vary from printer to printer and are documented in your printer manual Printer control data also can be linked to printer forms as described in sections 13 2 and 13 3 Control Code Entry Screen 1 From the Devices and Printers menu for the LPT COM or NET device select Printer Control Data Printer Control Data LPT1 printer type Generic The following information is optional Enter printer control codes Separate the control strings with 00 00 See Appendix B in your BARR RJE manual for hex coding of ASCII control characters HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Enter hex data 2 Enter the printer control data as pairs of hexadecimal digits 102 8 8 Printer Control Data As you enter each code the corresponding ASCII character displays in the space after
461. ntrol stops are used on the lines where the date payee name dollar amount and other information will print 7 When you press Enter the form list is updated to reflect the new form definition Edit Forms select one Escape STD CHECKS Selection l gt 8 To re display the forms in alphabetical order press Esc select Edit Forms and then press Enter Example 3 Skipping Over the Perforation This example illustrates stepping over the six lines that surround the page perforation The sample form is 88 lines long with vertical spacing of 8 lines per inch but you can print on only 82 of the lines 224 13 2 Edit Forms Edit Forms select one Escape CHECKS STD Selection l gt 1 Select a blank entry from the form list b oo Edit Forms P Name PERF a Lines per form 88 J Print lines per form 82 Lines per inch 8 Printer control 00 Enter character F 2 Enter the form name The form name you assign must match the form name specified in the host JCL for the job that generates the print output In this example the form name is PERF 3 Enter 88 for lines per form 82 for print lines per form and 8 for lines per inch 4 Press to display the Carriage Control Table screen Carriage Control Table The lines above the cursor show the form line numbers Enter carriage control characters 1 9 A B or C 000
462. ntroller Address of the other device When you connect to the mainframe the other device is the host When you connect to another PC the other device is the address of the other PC Coax Communications Statistics If you have a Coax connection you will see this screen 0 lines read 0 real buffers in use 0 lines printed or punched 150 real buffers free 0 SNA sessions active 0 XMS buffers in use 0 XMS buffers free reset Any key lines read Total number of data lines read by the Send command or LAN connections and sent to a destination by BARR RJE 382 23 3 Communications Statistics lines printed or punched Number of data lines received on the host print or punch stream by the Barr PC SNA sessions active Number of SNA RJE sessions currently active including printers punches readers console and commands from the keyboard real buffers in use Number of DOS communication buffers in use by BARR RJE real buffers free Number of DOS communication buffers available to BARR RJE Do not let this value reach 0 or the results might be unpredictable To be safe real buffers free should not fall below 20 during maximum use XMS buffers in use Number of extended memory communication buffers in use by BARR RJE XMS buffers free Number of extended memory communication buffers available to BARR RJE Do not let this value reach 0 or the results might be unpredictable To be safe XMS buff
463. nts you made from the Installation Description See Chapter 10 for more information about assigning devices Sessions During software operation you can move from session to session by using hot keys or the Sessions option Each session helps you accomplish different tasks When you start BARR RJE the software displays the initial session you selected in the Installation Description If you did not change the default 348 21 5 Advanced setting the software displays the Operation session See section 18 8 for more information about changing the initial session OPER DOS PRINT Use Hot Operation session This session displays the Operation screen discussed earlier in this chapter You can send commands to the host quit the program transfer files perform advanced operations and mount forms on the printer DOS session This session displays a DOS prompt so you can work in DOS without exiting BARR RJE Most programs that use stan dard DOS functions work in the DOS session However avoid using programs that turn off interrupts for extended periods of time or programs that use the same interrupts as BARR RJE because they might interfere with communications Also you might not be able to load large programs from the DOS session because of insufficient memory To leave the DOS session switch to another session or type exit at the DOS prompt Note You must have DOS version 3 0 or later to use the DOS session Pri
464. o determine whether expanded memory or upper block memory is installed The examples below show CONFIG SYS statements with and without upper block memory Extended Memory and Extended Memory Upper Memory Block DEVICE C DOS HIMEM SYS DEVICE C DOS HIMEM SYS DOS HIGH DEVICE C DOS EMM386 SYS NOEMS DOS HIGH UMB 38 6 2 Configure the PC Changes to AUTOEXEC BAT You must run the DOS SHARE EXE file sharing utility if you use the Barr print spool or LAN connections features and you use your local PC drive for the print spool or LAN connections directories The print spool and LAN connections features will not function properly unless you load this utility Add this line to your AUTOEXEC BAT file z N i o o 5 an e 2 5D i c dos share If you use your network drive for the print spool or LAN connections directories the network operating system handles file sharing See your DOS manual for more information about SHARE EXE KEJ install the Barr Software Files Your Barr software disk contains the Barr program and reference files in a self expanding compressed format The automated installation process copies the files to your PC and then expands them You can install the different types of software files in separate directories Software File Descriptions These files are part of the INSTALL EXE program and will not be loaded onto your PC READ ME A text file containing informa
465. o send a file on the SEND1 device the function key definition must begin with To send a file on the SEND2 device the function key definition must begin with 2 You can include more than one file name in a single function key definition Separate the file names with a space gt 7m 53 ix r A D lt a m You can use the prompt to prompt you for the file name but in that case using the Send Files command is just as easy Using Function Keys to Send Files to the Host This example assigns and to send files on the SEND1 and SEND2 devices respectively 1 From the Function Keys screen select Ctrl F1 to F10 to reach the Ctrl Function Key Definitions screen BARR RJE 253 z gt x i oO Lu a F1 Ctrl Function Key Definitions F2 F3 F4 F5 F6 F7 F8 F9 F0 Enter character On the first entry line for F1 enter the description Send DAILYRPT on SEND1 3 Press to reach the command entry line Enter the command ce dailyrpt The DAILYRPT file is located in the directory C in this example Press to store the command for F1 and advance to the entry line for F2 On the first entry line for F2 enter the description Send PAYROLL on SEND2 Press to reach the command entry line Enter the command 2 accting payroll The PAYROLL file
466. oa SVGA 6300 US Video VGA STB VGA EM 16 Tecmar VGA PowerGraph VGA PowerView VGA VgaWonder 1024 Trident SVGA Paradise 1024 ss _ z Ss v Ss s gt 2 D 3 ETF Screen Size Options Screen size choices depend on your selections for the Monitor and Adapter options If you select a screen size that is not compatible with the actual monitor or adapter the software uses a smaller screen size OPER screen size Specify the size of the Operation screen The Communication Scope Status Line console messages and Operation menu display on this screen DOS screen size Specify the size of the DOS session screen The DOS session displays the DOS prompt SPOOL screen size If you enabled the print spool feature specify the size of the spool screen You can display and manage files in the spool queue from this screen BARR RJE 201 TAPE screen size Specify the size of the TAPE session screen from which you can manage reading and writing magnetic tapes You can use this screen only with the BARR TAPE option EIE Screen Border Option Screen Borders Enabled Specify whether to use screen borders Yes Default Borders display around the edge of the screen No Screen borders do not display Some external screen saver programs might require you to select No to ensure that the screen goes blank If you enable borders some screen savers change the entire screen to the border color
467. ocal Area Transport LAT protocol This option supports up to eight LAT print sessions BARR PRINT for TCP IP You can share printing resources with your IBM mainframe and UNIX based computers BARR PRINT for TCP IP allows your PC to receive print output from UNIX hosts via Ethernet with TCP IP This option supports up to eight print queues with BSD 4 3 hosts or up to four print queues with System V hosts PRINT TWINAX You can share printing resources with your IBM mainframe AS 400 and S 3X systems PRINT TWINAX allows you to print to PC attached printers from your midrange system This option supports up to 12 print sessions from one or two midrange systems Each session can emulate a 5225 5219 5256 or 3812 in 5219 mode printer 32 4 6 Optional Features Software Screen Conventions This chapter describes conventions used in this manual and shows you how to navigate through the BARR RJE software screens EAN Screen Documentation Software screens appear inside a box Text marked with an arrow gt or numbered steps indicates an action to take For example BARR RJE Version 97A3 Product Options RJE SDLC The Installation Description configures the BARR RJE program The directions begin now Use the following keys to move around the screen t The Enter key advances you to the next screen The Esc key restores the original value of fields To print screen press both keys Shift PrtSc Any key
468. ocol s control functions This causes problems when data being sent contains the same codes as the communications control codes 28 4 4 Communications Features Character Set Conversion The RJE environment uses EBCDIC coding while much of the computer industry uses ASCII coding BARR RJE converts data between these character sets This feature is ideal for data transfer from PCs to the mainframe You can also use it when you input data from minicomputers and transfer it to the mainframe via BARR RJE A o gt J pes gt e aq m pag o 2 oO a Communications Statistics BARR RJE maintains statistics on the number of data blocks sent and received and communications errors encountered You can view these statistics on screen during software operation EFJ Diagnostic Features Built in diagnostic tools help you and Barr Technical Support resolve communication problems Detailed Error Messages BARR RJE displays error messages on the PC screen with self explanatory text You do not need to look up the meaning of an error reference number Barr Communication Scope and Status Line The first two lines on the BARR RJE Operation screen display detailed information about the communications activity and the current status of all devices The Communication Scope on the first line is a unique BARR RJE product feature It displays the type of blocks sent and received during the last 40 communications
469. odem you can program with the host phone number you can set it to automatically dial the number when it senses the Data Terminal Ready DTR signal from the software Your modem manual describes how to enable this feature Dataphone 2224B modem If you have the Dataphone 2224B modem select this option The Dataphone 2224B is a unique older modem that uses the 201C protocol This modem does not support the standard AT command set it is not Hayes compatible When you select this option the Modem Connection screen displays see section 12 2 You must also choose a modem standard on the Modem Options screen see section 12 3 a Fad i E a E v g i i N AT modem Select this option if you have an external AT modem that supports the standard AT command set Hayes compatible and can automati cally dial a phone number entered in the software When you select this option the Modem Connection screen displays see section 12 2 You must also choose a modem standard on the Modem Options screen see section 12 4 Escape To return to the Installation Description menu select this option or press Esc 204 12 1 Modem Selections EEF Modem Connection Screen If you select BARR PC SYNC modem Dataphone 2224B modem or AT modem from the Modem Type and Dialing Instructions screen the Modem Connection screen displays Modem Connection Phone numbers Modify options No Enter
470. oftware loads two form overlay files The overlay file that matches the UCS print train name is sent to the printer followed by the overlay file that matches the FCB name With this selection beginning UCS overlay files must have a file extension of UCS and beginning FCB overlay files must have a file extension of FCB This is the only case where file extensions are valid for beginning overlay files The UCS print train name and FCB name are obtained from the host PDIR record JOBNAME Load form overlay file Use this option to control how often the form overlay file is sent Always When Search Criteria Changes The job name for the file is used as the overlay search name ob oo im kzi i gt an Send the form overlay file with each file Send the form overlay file only when the overlay file name changes Use this choice if you create large form overlay files Sending large form overlay files with every file can slow printing Because the printer can store the overlay file it is not necessary to send the same overlay file with consecutive jobs Use default overlay file if overlay not found Specify whether to use a default overlay file if the specified overlay file is not found in the forms overlay directory No Yes Default Use this choice if overlay files are not required for all print files or if you prefer to suspend printing by using the Suspend printing if overlay not found option
471. oftware update choose which files to install and select whether to enter the configuration settings now or later If you are installing a software update you might want to save the config uration settings from your working copy before you begin See step 3 Follow these basic steps to load the software files 1 Insert the software disk 2 Type the install command at the DOS prompt 3 Choose whether to install a software update or new software 4 Choose which files to install and which directories to install them in 5 Choose whether to configure the software now or later The automated installation process is easy to use The rest of this section provides detailed instructions for each of these steps 40 6 3 Install the Barr Software Files 1 Insert the software disk a Start the PC with DOS version 3 0 or later Monochrome monitors If your PC has a monochrome monitor and a color adapter CGA EGA VGA you need to set the display mode to black and white so you can read the software screens Enter this command from the DOS prompt mode bw80 z N i o o 5 an e D 5D i b Put the Barr software disk in the PC disk drive 2 Type the INSTALL command At the DOS prompt enter the drive letter followed by the INSTALL command For example if you put the disk in drive A you would type this command a install 3 Choose Update or New Installation This menu displays when
472. oice might be necessary with forms that do not have a 1 in the first position of the VFU To print extended ASCII codes such as the cent symbol you must set this option to No Yes Use VFU to control line skips The Dataproducts BP1500 requires a 1 in the first position of the VFU You also should set Printer performance optimized to Yes Printer timing delay Some line printers cannot accept data as quickly as the software can send it You can use this option to slow the rate at which data is sent to the printer so the printer does not become backed up Indications that you need to adjust this value include dropped or duplicate characters in the print output You also might need to use this option with forms that do not have a 1 in the first position of the VFU Note The timing delay feature applies only to line printers not to laser printers Line printers use a busy line to signal whether they can receive data When a printer is busy it sets the busy line Before the software sends data to the printer it checks whether the busy line is set If the busy line is active the software pauses before sending more data However some printers are slow to set the busy line The Printer timing delay option introduces a delay after each byte sent to the printer so the printer has time to set the busy line before the software sends more data 58 8 3 LPT1 LPT3 Devices Because the timing delay is measured in internal program cycles
473. ol 5 1 Type the PRT command at the DOS prompt The PRT screen displays a N Directory of C BARR 9 File Size Date Time File Size Date Time BARR CFG 14120 03 26 97 10 39 TEST CTR 120 03 26 97 14 51 SPOOLP EXE 177917 03 27 97 13 21 SPOOLP4 EXE 180205 03 27 97 10 43 PRT EXE 157290 03 27 97 10 02 START JOB 19 03 26 97 10 36 END JOB 18 03 26 97 10 36 JOB 15 03 26 97 10 37 SPOOL EXE 156413 03 26 97 11 23 SPOOL CTR 120 03 26 97 14 51 SCAP ASC 765 03 28 97 08 31 SCREEN CUT 2492 03 28 97 09 14 FD 328 03 28 97 11 06 MYLIST 15 03 28 97 11 48 OVERRIDE CTR 120 03 26 97 14 51 ALT 174 03 28 97 11 49 Spool File File Directory DOS Controls View File Quit Copy a file into the spool directory 444 25 3 Operate the PRT Utility The files in the current directory display in a two column listing Commands display at the bottom of the screen 2 To select a command move the cursor to the desired command or type the command s first letter and then press Enter PRT Commands PRT commands are described below Spool File Submit a file to the print spool using the current spool control options You can select a file from the list or enter a file name Controls File View DOS Quit Load change and save the spool control options The SPOOL CTR options are loaded by default Directory Change the file directory listing on the PRT screen The name of the current directory displays at the top of the scre
474. ol printer for each destina tion device You can choose from 0 to 8 spool printers The default number of spool printers is 1 To disable the print spool feature set this value to 0 A list of spool printers displays at the top of the Print Spool screen during software operation On the Assign Devices screen spool printers display as the devices SPOOL1 to SPOOL8 See Chapter 10 for more information about assigning spool printers to destination devices Performance Tuning If you do not use the print spool option set the number of spool printers to 0 This frees PC memory and makes it available to other software features BARR RJE 123 SPOOL directory Assign a name to the DOS directory that serves as the spool print queue Files stored in this directory display on the Print Spool screen The default directory name is C SPOOL You might want to specify a directory on the network to enable users on the LAN to submit files to the spool directory When you start BARR RJE for the first time the software automatically creates this directory Note In the Assign Devices list of destination choices the print spool device appears as SPOOL The name you assign to the print spool directory does not change the SPOOL device name on the Assign Devices screen i o N o a i A a oa Retain directory An optional directory for automatically storing spool files after they print or you delete them You migh
475. old Print Test Page Print the current page and advance to the next page You can use this option to verify that data is printing correctly on a form If the test page prints incorrectly you can change the form alignment and print another test page When the test page prints correctly you can continue to print the rest of the file PZJ Managing an External FAT File You can view an external FAT file from the Print Spool screen If you create an external FAT file as described in section 9 6 the external FAT file is loaded into extended memory XMS when the Barr software starts FAT entries are applied to files as they are placed in the Print Spool The applied changes are written to the spool headers for each file i o 5 f i i 72 i A N When you make changes to the external FAT file the changes only affect files that have not yet been received Files already in the Print Spool will not be affected You can change attributes for files that are already in the spool directory from the Print Spool screen View the FAT Before you use a newly created or modified external FAT file you should view the table and check for errors Also whenever you encounter problems with spool files affected by the FAT you can use the viewing feature to help diagnose them 428 24 8 Managing an External FAT File Note After you edit the external FAT file you should disable the spool printers
476. olved 358 21 7 Console Messages Error Messages You might see error messages on the console when you operate the software Disk Full Error If the PC disk becomes full when you are writing files to disk messages like this display Disk full Error on file C NEWFILES JOB1 J0B BARR RJE also suspends the device that was receiving the file To correct this condition follow these steps 1 Free disk space by deleting unnecessary files from the hard drive or moving them to another disk 2 Re assign the suspended device See your DOS manual for information about deleting files See Chapter 10 for information about assigning devices and the SUSPEND destination The console message includes the name and location of the file the software was writing when the disk became full If the file was assigned to write to a file such as PR1 FILE the message path and file name come from the Beginning of file name and Ending of file name fields on the Assign Devices screen If the file was assigned to write to the print spool the path comes from the Print Spool Description screen and the file name comes from the Beginning of file name and Ending of file name Assign Devices fields N _ o gt eoj ps J amp m i 3 2 5 When you assign file names explicitly define the drive and path names so error messages can point you to the exact file location File Name Errors When you receive files to
477. one source device to different destination devices as shown in Figure 9 2 PC Printer 1 Barr Spool PC Printer 2 Figure 9 2 The print spool routes some files from the PR1 print stream to PC Printer 1 and other files to PC Printer 2 120 9 1 How the Print Spool Works Attributes Control File Routing To determine to which PC printer or other destination to route a file the print spool matches file attributes to spool printer attributes and spool printers to device assignments As each file writes to the print spool the Barr software adds a spool header to the file The spool header contains attributes that describe the file and how it should print For example the copies attribute indicates how many copies of the file the software should print and the form attribute indicates what type of paper the PC operator should load in the printer The attributes for each file display on the Print Spool screen wo im 5 nm r i i D a ir 3 r Ej When you set up the print spool you define spool printers and specify attributes for each one A spool printer acts like a router It directs files from the print spool to their actual destination The software compares each file s attributes to the spool printer attributes When a file s attributes match the attributes of a spool printer on the Print Spool screen the software directs the file to the destination associated with that spool p
478. one for 3 seconds It then begins communication Manual You will manually dial the phone Autodial retries This option specifies the maximum number of times the software tries to make the modem connection if the first attempt is unsuccessful The default value 999 indicates the software will retry the connection indefinitely When the software tries the specified number of retries it exits to DOS BARR RJE 207 Wait for dial tone Select whether to wait for a dial tone before dialing Yes Default Wait for a dial tone before dialing No Begin dialing without waiting for a dial tone Starting time Use this option for delayed communications startup unattended operation or dialing after normal business hours to save long distance phone charges Normally you do not need to enter a connection start time If you leave this option blank the Barr software immediately tries to make the connection when it starts If you specify a starting time after startup the Barr software waits until the time indicated to make the connection If the software starts within 8 hours after the specified time the software makes an immediate connection rather than waiting for the next occurrence of the starting time a Fad i E a E v g i i N When you enter a starting time use the 24 hour scheme where 1 a m is 01 00 and 1 p m is 13 00 Verify that the time on your PC is correct use the DOS time command to en
479. only the first 69 bytes of information are recorded including nine bytes of link control information and 60 bytes of data A short line trace is preferred when you examine link control issues such as difficulty logging on or unexpected disconnects full Use the full line trace format For each frame of data all information is recorded including nine bytes of link control information and all of the data bytes A full line trace is preferred when you examine data issues such as printing problems mode Select whether to use the software in test mode During test mode you can use all the BARR RJE functions but the software does not 306 18 6 Trace and Memory Options connect to the host computer Test mode is a useful tool when you are learning about the software or testing software features No Default Test mode is disabled The software is used in normal mode Yes Test mode is enabled While in test mode Commands normally directed to the host computer are sent to the destination SCREEN RD1 input is sent directly to PR1 and RD2 input is sent directly to PR2 without first being routed to the host computer For example if you set SEND1 RD1 and PR1 LPT1 on the Assign Devices screen the Send Files command routes PC files directly to LPT1 Note Remember to disable test mode when you are ready to communicate with the host pes oo z im gz i gt a Display and Disk Options Sever
480. ons are unique to this screen you can restore files and display file attributes for individual files Restore a File Follow these steps to restore a file to the spool directory 1 Select a file with the arrows 2 Press the to mark files to restore 421 N A m 3 N g 2 3 e S 3 Press to restore the selected files 4 Press to return to the Print Spool screen 5 Change file attributes for the restored files if necessary 6 Press to resume spool operations View File Attributes On the Restore screen you might need to display file attributes to identify which files to reprint If you have disabled the automatic display of file attributes to improve Restore screen performance you can use either the View File or View Header commands to display the attributes for indivi dual files After you use one of these commands the Restore screen displays the attributes for the selected file The following example shows you how you can use the View File command to display attributes for a file Restoring files from C SPOOLRET Spooling paused File State Form Class Prty Copies Size Date Time z PAYROLL 003 10023 02 12 97 7 49 PAYROLL 002 7099 02 12 97 8 03 5 PAYROLL 001 13240 02 12 97 8 29 a e a 7 Select file using and press Space to mark V to view or n H to view header Ins restores files Del deletes files a Sort Escape
481. ool Operation for more information about the spool Restore feature See Retain Options later in this section for more retain options Allow operator to modify file attributes Choose whether the PC operator can change the attributes of spool files from the Print Spool screen You can allow the operator to change fields as needed or you can use fixed criteria that the operator cannot change BARR RJE 129 Yes Default From the Print Spool screen the operator can use the File command to modify file attributes that control which jobs print The operator can change these attributes State Disposition Form Class Priority and Copies For more information about this feature see section 24 3 Files Command No Operators cannot alter file attributes that control which jobs print This option ensures that the same preset criteria are always used to control print jobs The operator also cannot view files or their spool headers or delete files When you choose this option the Ready Files command replaces the Files command on the Print Spool screen The operator can use the Ready Files command to change the file state from Hold to Ready usually to recover from spool or printer errors For more information about this feature see section 24 3 Files Command i o N o a i A a oa Check SPOOL directory for new files every seconds Specify how often the software will check for new files in th
482. oopback test plug comes with the SYNC ISA cable _ N 53 o 3 J D 2 an e No Default Do not perform the test Yes Run this test after hardware and software installation when you change the settings on this screen or if you suspect a hardware error The loopback test performs diagnostics on the synchronous adapter cable and modem Instructions display on the screen for each step See section 17 2 for detailed information about the loopback test After you make your selections and press Enter a screen similar to the one below displays additional adapter information Your screen reflects the settings you selected BARR RJE 263 Interrupt Request Address and Loopback Test For SYNC adapter set jumper for address 280 For BARR 3 adapter set jumper for address 280 For BARR 2 adapter set jumpers for IRQ2 and address 280 For BARR PC SYNC modem set jumper for IRQ2 the DIP switches are shown below HH HH a The DIP switches on the board are set ON W OFF i E Log ee Ao Be oT g The BARR PC SYNC modem V 32 cannot be set to address 280 Any key Note The BARR 2 and BARR PC SYNC are older adapters that have been discontinued Press any key to continue z N 5 amp c a 5 poa S las Perform Loopback Test Barr software includes an adapter loopback test which verifies that the adapter func
483. operating system for computers that uses disks to store programs and data DOS POWER See VSE POWER driver See device driver EBCDIC Extended Binary Coded Decimal Interchange Code which specifies a set of 256 graphic and control symbols and their eight bit codes EBCDIC is used by mainframes and mainframe peripheral Messoj9 BARR RJE 537 devices such as printers It was first used with the IBM System 360 EGA Enhanced Graphics Adapter a type of video adapter EISA Extended Industry Standard Architecture A 32 bit extension of the 8 and 16 bit internal bus structure developed by IBM Developed by Compaq Computer Corp and other PC manufacturers encrypt Systematic alteration of data that prevents unauthorized persons from viewing and using the data Ethernet A LAN physical standard that allows multiple stations to access the trans mission medium extension In a file name one to three characters that follow the period for example STUDY5 JOB FCB Forms Control Buffer A buffer for controlling the vertical format of printed output FCBLOAD Forms Control Buffer Load A record sent from a host to a remote to specify vertical forms control FCC Federal Communications Commission file mark Used to mark the end of a file file transfer Transfer of files between two computer systems flag In SNA communications an eight bit character used to introduce and end SDLC transmission f
484. or device driver software turns off interrupts or when data transmission errors occur If a serial device is used as both a data source and a destination and XON XOFF flow control is specified XON XOFF flow control will work in both directions Serial Input Options When you input data on the serial port you need to set the options described in this section gt From the Serial Port Options screen set Use this device as a data Source as well as a Destination to Yes The following screen displays BARR RJE 67 Serial Port Source Options COM1 printer type Generic Input mode ASCII Length of end of file marker 1 End of file marker 1A Strip leading nulls Yes Card reader input No Close input file on timeout No Timeout in seconds 30 n o 2 a 3 n a 2 gt i Choice Input mode Select the character set of the data to be input on the serial port ASCII Default Data to be input on the serial port is in ASCII format To determine the end of the input file the software checks for the end of file character you specify with the End of file marker option When BARR RJE reaches the end of the file it adds the DOS end of file character hexadecimal 1A before it routes the file to the destination device If you set the End of file marker option to a value other than 1A BARR RJE performs additional processing The software converts any
485. or the file is assigned a unique extension If a new file s name does not have an extension or if a file with the same name exists BARR RJE generates a numeric file extension and adds it to the name of the new file When duplicate file names are encountered this method preserves the existing file See File Name Extensions later in this section for an example of the file naming sequence BARR RJE 165 If a new file s name includes an extension or ends in a period the new file replaces the existing file For example a file named DAILYRPT or DAILYRPT MON would replace a file that has the same name Log No Log This option controls whether informational messages display on the console when files are written to disk Log Default Each time a file is written to disk messages display on the console indicating the start and end of the file For example WRITING DAILYRPT CLOSE DAILYRPT 4 2 gt 7 i K These messages are included in the console log file if you enable the log file by directing LOG FILE on the Assign Devices screen No Log Messages are not written to the screen or the console log file This selection reduces the number of messages on the screen and in the console log file File Name Extensions File name extensions allow greater flexibility for naming files A file extension consists of a period or a period followed by up to three characters for example
486. orm name only See FCB FORM to Print Queue Translation Table later in this section RJE 3270 If you have RJE 3270 software you can use this method only for RJE data streams not 3270 streams i S o N 2 3 3 mr 5 D R 77 Print form header Choose whether to process or send the Barr spool header No Default BARR RJE converts the spool header information to printer instructions and sends them to the destination device You can use this choice if you select line printer daemon as the protocol Yes BARR RJE sends the spool header so the receiving PC can process the header information You can use this choice for either the line printer daemon or native TCP IP protocols Use print banners Choose whether to include banner pages in print jobs You can use banner pages to help identify printouts This option is valid only if you select the line printer daemon protocol Yes Default The Barr software sends a request to the LPD server to generate a banner page The LPD server uses information from the control file including the job name host name user name file name and class name to build the banner BARR RJE 85 No The software does not send a banner page request Send Control file first An LPR print job consists of two files a data file and a control file The data file contains the print data and the control file contains attributes describing the print data You can choose w
487. orm overlays 100 function keys 252 253 347 LAN connections 110 A command 461 B command 462 C command 463 D command 242 243 DF command 467 DJ command 468 DU PR1 command 466 E command 240 243 469 F command 469 H command 470 HASP190 See HASP190 I command 243 471 L command 472 N command 472 O command 473 P command 240 242 R command 475 S command 238 240 242 476 T command 192 240 242 243 284 286 477 Z command 480 receive mode indicator 177 197 F command 482 I command 482 R command 483 S command 484 X command 484 1 send mode 110 1Q40A message 238 284 2UP overlay file 100 3174 control unit 19 controller 27 3270 applications 16 18 screen size 199 session 312 translation tables 278 280 workstations 18 3270 printer 18 emulation 30 options 292 3270 terminal 17 18 emulation 10 30 3274 control unit 19 3299 protocol 27 3704 FEP 19 3705 FEP 19 3725 FEP 19 27 3745 FEP 19 27 3777 3 Remote 10 17 457 802 2 14 BARR RJE version 27 communications statistics 380 Link statistics 382 maximum frames received 299 network connection 27 SAP statistics 381 scope characters 369 tuning options 299 A Aborted frame 367 ACDU Automatic Call Distributing Unit 451 Adapter address 262 266 269 BARR PC SYNC 264 BARR 2 264 BARR 3 264 Coax 27 conflicts 269 diagnostics 264 Ethernet 14 installing 269 resources 261 RS232 263 serial n
488. osition of original file after 8 Nochange copying to the Spool directory Delete Rename LPI Lines per inch setting for printer 1 1 9 LPF Lines per form setting for printer 3 1 999 PLPF Print lines per form setting for 3 1 999 printer PRIORITY Priority to be assigned to file 1 0 9 RETAINDIR PRT Retain directory if original 64 file is to be retained after copying to spool directory SPLDISP Disposition of spool file after 8 Delete printing Rename SPOOLDIR Spool directory 64 STATE State to be assigned to file 5 Ready Hold BARR RJE 443 N 7 3 a 5 n z Example Batch Mode Commands These examples illustrate how you can use the PRT batch command to spool files This command adds the REPORTS TXT file to the print spool by using the default control file SPOOL CTR prt report5 txt a This command adds the SEPT 001 file to the print spool sets the number of copies to 5 and the form name to CHECK and uses the default values from SPOOL CTR for all other options prt sept 001 cop 5 form check a This command adds the file MYLIST to the print spool sets the number of copies to 10 and uses values from the LISTING CTR control file for all other options prt mylist listing ctr copies 10 Interactive Mode When you run PRT interactively it lists the current directory on the screen You can change directories view files and assign control options zZ before you copy a file to the print spo
489. ot writer to send the output in the specified class WC class to printer 1 OUT PR1 X WIR OUT PR2 A NAV C WC A F STD H H N B N calls the hot writer to send class A output WC A on only the designated standard form F STD H to printer 2 OUT PR2 The writer will process output automatically as long as work is selected A If the device is not available the writer will be terminated NAV C No header pages H N or trailer pages B N will be included EEJ VSE POWER Remote Commands Operators can enter the VSE POWER commands listed in this section from the Barr console Commands operators enter from the host console gt are slightly different In VSE POWER commands LST or LST1 LST2 and so forth is a printer device and PUN is a punch device z o VSE POWER Commands 5 2 Command Controls or Displays 2 A alter device D display device I inquire device line or LU P stop task task R release device S start device device or task Each command is described in a separate subsection BARR RJE 485 VSE POWER Command Format Enter VSE POWER commands from a console as follows command operandi operand2 where command is a single character that identifies the action to take operand modifies the command Use a comma to separate operands A Alter Device Characteristics The A command changes device characteristics Format A device options where device is LST list queue PUN punch RDR reader or
490. ou can obtain the serial number from the front of the adapter box the sticker on the adapter edge that is visible from the rear of the PC or the back of the adapter where it is handwritten Problem number If you are calling about a new problem a Barr support analyst will assign you a problem number Be sure to note the problem number for future reference If you are calling about a previously reported problem tell the support analyst your assigned problem number Version number Determine the Barr software version number for example 97A3 so you can provide it to the support analyst The version number displays on the second screen of the Installation Description the console portion of the Operation screen at software startup or the Quit menu during software operation Problem Description Be prepared to supply details about your problem Barr support analysts also might ask you to supply information about your host computer PC or printers Diagnostics If you are asked to provide a line trace memory dump or other diagnostic information please respond as quickly as possible Your quick response helps Technical Support solve the problem in a timely manner and underscores your level of concern Schedule for return calls If you are frequently away from the phone please advise the Technical Support staff of the best time to reach you iv Preface Contents of i Ao a nee en a a a ir iii Chapter 1 Introduction i isis
491. ou might want to use control codes when the printer is shared by the Barr PC and users on the network In this example control strings cause files sent by the Barr software to print in a compressed text format and files sent from other sources to print at a normal density oo o S o D a 2 Ss gt me Ss ae a The control code 0F causes the EPSON IBM printer to print compressed text at a density of 132 characters per line To reset the printer at the end of each file use the end of file string that begins with FF For the EPSON IBM printer the reset code is 12 Each control string is termi nated with a 00 00 sequence HEX OF 00 00 FF 12 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HEX 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Example 4 Serial Port Input Header The serial port input header starts with FE BARR RJE adds this control string to the beginning of each data file input on the selected serial COM port rather than sending it to the printer as control codes This example shows how to insert Job Control Language JCL at the begin ning of files as they are input on the serial port so the files can be submitted to the host as jobs The control codes shown below are the hexadecimal translation of the following JCL XX JOB ACCOUNT EXEC WORK HEX 00 00 FE 2F 2F 58 58 20 4A 4F 42 20 41 43 43 4F 55 4E 54 0D HEX 2F 2F 20 45 58 45 43 20 57 4F 52 4B
492. p entry number is updated as you scroll through the table Use these keys to view the FAT table m and scroll through the table entries n returns to the Print Spool screen Diagnose and Correct Errors For each FAT entry check that all fields display and that the fields display in the correct columns Missing or misplaced fields indicate that you omitted comma delimiters For example the first entry of the example FAT table is missing a comma at the end of the file name or as a place holder in the Form column This causes the HOLD state to shift one column to the left and display in the form column You can only view table entries from this screen To correct table entries you must edit the external FAT file see section 9 6 and then refresh the FAT table see Refresh the FAT later in this section Other types of errors might prevent the File Attribute Table screen from displaying Instead of the table this message displays at the bottom of the Print Spool screen An error occurred reading SPOOL FAT file Hot Key to the OPER console to view error messages Any key 1 Press to clear the message text o i i 72 pan i Q N 2 Switch to the console portion of the Operation screen and look for any error messages that reference the spool FAT Typically several messages display The first message usually is as follows Error opening SPOOL FAT file
493. pe frames overflowed buffer Number of SDLC frames whose size exceeded the Barr communi cations buffer Usually caused by an error in the frame or MAXDATA at the host exceeding MAXDATA in the BARR RJE configuration Indicated by a ii on the Communication Scope an o S a D S a E E o m N times no reply received in time Count of receive timeouts Whether Barr is a remote or host the program expects to receive frames in a timely manner usually within 3 seconds Indicated by a H or M on the Communication Scope frames aborted Number of aborted frames received by BARR RJE Indicated by an FV on the Communication Scope equipment errors Count of equipment errors caused by any of the following 378 23 3 Communications Statistics Receive overrun An on the Scope Transmit underrun An 44 on the Scope Transmit timeout An i on the Scope Usually caused by missing clock Missing CTS A on the Scope Page 3 SDLC Communications Statistics gt Press N to advance to page 3 0 full duplex frames received 0 Rej retransmissions 0 frames received out of sequence 0 Rej frames sent 0 checkpoint retransmissions 0 Rej frames received page 3 next page reset Any key full duplex frames received Number of SDLC frames received while BARR RJE has the poll and is able to transmit For half duplex operation this will always be zero If this remains zero after
494. per page 523 remote vs local 522 spool header 505 512 Carriage Control Table Edit Forms 219 221 not used 235 screen 220 Carriage return CR discard on serial port 70 Cent symbol print 58 94 CFG file extension 316 CGA monitor 200 Channel stop error message 286 Channel attached printers 31 Character set fixed length receive mode 184 native language 275 276 Characters per inch 102 Check Spool command 411 418 Check SPOOL directory for new files 130 Checkpoint retransmissions 379 Checks printing 223 Choice prompt 34 Choose language for translation tables 275 277 Choose Printer Type screen 93 Circumflex translation of 491 Class Assign Devices option 189 See also File attributes form name equals 191 OUTPUT statement 187 spool header 510 Class Z files 148 192 409 507 Clear To Send CTS CTS 0 65 delay 210 modem 297 serial port 64 497 499 Status Line 325 Close input file on timeout 71 BARR RJE 553 Coax BARR RJE version 27 communications statistics 382 scope characters 371 Color display 23 COM Device screen 61 COM files sending 453 COM port data conversion 451 COM1 COM4 13 21 53 497 destination 153 158 disable 62 enable 61 66 options 62 source 65 153 154 195 COMMAND device 153 158 176 186 assigning KEYBOARD to 154 158 Command strings AT modem 211 Command to Host 155 156 screen 335 sent with forms 216 237 238 serial port input of 66 68 Command to Host opt
495. perating it periodically checks the directory and sends the files to the host N o gt J eoj ps J amp m i 3 o 5 Automatically Delete Files after Sending Them You can automatically delete files from disk after you send them to an assigned destination by appending delete to the Send Files command When you specify a send mode the delete option must follow the send mode For example to send the file DATA in binary mode and delete it from disk after sending enter this command BARR RJE 347 Enter file names To combine files separate by a plus To start a new file leave a blank To cancel press Esc Files DATA B DELETE AEJ Advanced Use the Advanced option to assign devices move from one session to another or diagnose problems Operation Command to Host Send Files to RD2 Advanced Quit Send Files to PROE Mount Forms Selectiont gt gt From the Operation screen select Advanced to reach the Advanced menu Advanced Assign Devices Diagnostics Sessions Escape Selection tJ i o a i Wu c gt s c co rr N Assign Devices Use the Assign Devices option to change source and destination device assignments during BARR RJE operation Your changes remain in effect until you exit or restart BARR RJE When you start BARR RJE it uses the device assignme
496. peration BARR RJE prompts you to enter the missing parameter In this example you supply the number of the RJE printer After you enter the parameter and press Enter the software sends the command to the host 14 5 Using Function Keys with Send Files Commands If you regularly send files with the same name to the host computer you can define a function key to send the file instead of using the Send Files option on the Operation menu For example suppose you need to send a daily report DAILYRPT and a weekly payroll statement PAYROLL to the host and the files always have the same names The Send Files option requires you to enter the file name each time you send the command and is the preferred option if you send many files with different names To set up this feature include the Barr embedded send command or 2 and the name of the file in the function key definition For more information about sending files to the host see Chapter 21 252 14 5 Using Function Keys with Send Files Commands Note Before you press a function key that contains an embedded send command check the Assign Devices screen to make sure you assigned the correct destination to the SEND device Including a Send Command in a Function Key Definition To use the embedded send command in a function key definition follow these guidelines The format of the command is filename The file name should include the file s full directory path T
497. perator intervention is required before any more print files can be sent from the specified source device to the printer Other Print Options These options affect data received on all the RJE printer devices PR1 to PR7 Insert tabs to compress data on disk Choose whether to replace series of blank characters with tab characters to save disk space No Default Do not substitute tab characters for sequences of blanks Yes Use a tab character to represent up to eight blank characters in a sequence Tabs are substituted as the data is received to the 290 18 2 Printer Control PC This choice saves PC disk space when print files are written to disk Interleaved binary data Maximum print position XPAF Indicate whether print files contain binary data interleaved with EBCDIC text Binary data is similar to EBCDIC data but does not include carriage control This option is useful if files contain plot data in binary format interleaved with text No Default Print files do not contain both binary data and EBCDIC text Yes Some data lines in a file might be in binary format while other lines might be in EBCDIC format Binary data lines begin with a hexadecimal 04 For each line of binary data the software uses the number in column 2 to indicate the number of data bytes in the line This count might differ from the actual number of characters in the line because JES2 truncates trailing blanks BARR RJE adds trailing bl
498. ponse Sense Data 08210000010681 VTAM Diagnosis Guide SC27 0615 A 15 In this example the remote name or password is incorrect 1 01 06 04 81 08 01 00 00 06 F3 08 D5 C5 D9 F1 D1 C5 E2 F2 F3 08 E3 C5 C4 F1 E3 C2 FO FO a 3 NERIJES23 TED1TBOO 01 06 04 81 08 01 00 00 06 F3 08 D5 C5 D9 F1 D1 C5 E2 F2 F3 08 E3 C5 C4 F1 E3 C2 FO F1 a 3 NERIJES23 TEDITBO1 01 06 04 81 08 01 00 00 06 F3 08 D5 C5 D9 F1 D1 C5 E2 F2 F3 08 E3 C5 C4 F1 E3 C2 FO F2 a 3 NERIJES23 TED1TBO2 N w 330 20 3 Monitoring the Logon Process In this example the number of LUs is incorrect The VTAM PU definition specifies more LUs than the NCP MAXLU parameter LU 5 Response Sense Data 08090000010681 VTAM Diagnosis Guide C27 0615 A 15 In this example the reader device is not started The reader device was drained or not defined in JES2 LU 1 Response Sense Data 08250000060120 VTAM Diagnosis Guide C27 0615 A 15 N w gt J J J m a D BARR RJE 331 Notes 2 E 7 W cc th cc cc lt A 332 20 3 Monitoring the Logon Process BARR RJE Operation ARI Command Menu BARR RJE s primary purpose is to transfer files between the PC and a host computer You can perform most file transfer functions from the Operation screen File transfer operations include send
499. print form The DAVFU convention was first established by Dataproducts Corporation dedicated line Same as a non switched line A connec tion between systems or devices that does not have to be made by dialing demodulate The reverse operation of modulate Transforming an analog signal into the digital information it represents See also modem device An input and output unit connected to the computer such as a printer plotter or monitor device address A number that uniquely identifies a device device driver A software program that controls a specific device such as a printer or a network connection Drivers load into memory and stay active while the computer does other work diagnostics A program to detect and isolate errors in programs and faults in equipment dial up line A telephone line connected to the switched telephone network where the destination is selected by dialing a multi digit number Also called a switched line or a dial line Opposite of leased line or dedicated line disconnect Terminate a physical connection disk A flexible magnetic coated mylar disk used to record information Synonymous with flexible disk or floppy disk display A TV like device used to display infor mation DMA Direct memory access A technique for moving data directly between main storage and peripheral equipment without requiring the processing unit to process the data DOS Disk operating system An
500. printer type Serial port options Escape Miscellaneous printer options Printer control data Escape Selection tJ The same choices display for each COM device Use this device Enable the COM device You must select this option to enable the device before you can use it The selected COM device displays as a destination device on the Assign Devices screen BARR RJE 61 Delete this device Default Disable the COM device and remove it from the Assign Devices screen The status deleted displays next to the device name at the top of the screen The Assign Devices screen is easier to read if you disable devices you do not intend to use Performance Tuning Disable any serial devices you do not use This frees buffers and makes them available to other program features Choose printer type You must choose the type of printer to use When you select this option a list of printers displays Section 8 6 describes the printer choices After you make a selection your choice displays on the Devices and Printers menu next to the device name n o 2 E a 3 G a a Fq oa Serial port options You must specify additional information about the COM port The mode of the serial port including baud parity data bits and stop bits must match the mode of the device attached to the serial port Consult your serial device s user manual for the mode settings When you select this op
501. prompted to specify the location of the name within the file See Example 4 later in this section 164 10 5 Assigning a File as a Destination File Options Specify how to handle duplicate file names and whether to log file activity when you write to a file destination New File Append Replace Replace Cond If a duplicate file name is encountered choose whether to create a new file append to the existing file or replace the existing file This selection displays to the right of Ending of file name New File Default If a new file does not have an extension or another file has the same name BARR RJE generates a numeric file extension and adds it to the name of the new file When duplicate file names are encountered this method preserves the existing file See File Name Extensions later in this section for an example of the file naming sequence tk A 2 5 S o D 7 Append The new file is added to the end of the existing file with the same name When you receive files to the print spool SPOOL do not use this choice Replace The new file overwrites the existing file This choice might be useful if you receive a file with the same name each day and you do not want a large number of files to accumulate on the PC disk This choice saves you the work of manually deleting the old files Replace Cond Replace conditional The method used for naming the file determines whether the file is replaced
502. provide If you use HASP190 FCBNAME or SETUPHDR FCBNAME to automatically mount forms the form name you assign must match the FCB name the host will provide Section 18 2 Tuning and Global Options Printer Control describes the options that control automatic forms mounting 218 13 2 Edit Forms Helpful hint You can define fewer Barr forms if the name you assign matches the host FCB name instead of the host form name Because several forms can use the same FCB the number of FCBs needed is less than the number of forms needed Lines per form Specify the number of lines that can fit on the paper form This value is the page length in inches multiplied by the number of print lines per inch For example an 11 inch page with 6 lines per inch has 66 lines per form Print lines per form Specify the maximum number of print lines available on the paper form Usually this number is the same as lines per form If this number is less than the lines per form it indicates that some lines at the top or bottom of the page will be skipped during printing h oo im 5 Q n 3 a If you select an ASCII receive mode in the software this setting controls when form feeds occur during printing As data is sent to the printer the software counts the number of print lines and issues a form feed when the print lines per form is reached Then the counter is set to 0 and the process begins again If form feeds are already inc
503. pter 25 25 1 25 2 25 3 Chapter 26 26 1 26 2 26 3 26 4 Appendix A A l A 2 A3 Appendix B B 1 B 2 Managing an External FAT File 0 428 VEW the FAT cdiiee vet cet EE A E A N E 8 uit EAA A 428 Diagnose and Correct Errors 2 0 0 0 0 cee ee eee eee 430 Refresh the FAT si tok ccna cht ates 2404 E EME ER ele a yee edna hed 431 Spool PRT Utility ccc e eas see 433 Install the PRT Program 0 0 0 0 ee eee 433 Create Control Files eissir 0 cee eee eee eens 434 Maintain Control Files Interactively 00 434 Maintain Control Files with an ASCII Editor 441 Operate the PRT Utility eai eenaa i a naia 442 Batch Mode Resa EESAN iin EEA EEO tines 442 Interactive Mode sorire a T EAE E Oe aw AA 444 Special Applications 00 cece eee eee 451 Converting Data for Serial Port Input 451 Types of Applications 0 0 eee eee 451 Conversion Steps ocres rorot eee ee eee eects 452 Transferring Files from PC to PC 00 453 File Transfer by Dial Up Connection 04 453 File Transfer through the JES2 Network 454 Packaging BARR RJE in an Application 455 Packaging BARR RJE 2 eee eee 455 Changing Your Application Program Code 455 Assuming the Host Communication Role 457 When to Use Host Mode
504. r Device name Enter the DOS device name for the network printer You can specify the name of a device or a file Common device names are LPT1 LPT2 or LPT3 If you specify a device you must enable network redirection of the device on the network See your network manager if you need assistance BARR RJE amp 1 If you specify a file name the file extension is optional When BARR RJE writes to a file any files with duplicate names are renamed using automatic generation of numeric file extensions The software assigns the first file with a duplicate name an extension of 001 the next file with that name an extension of 002 and so on For an example of the automatic naming sequence see File Name Extensions in section 10 5 TCP IP LPR UNIX Print Queue Support for TCP IP LPR print queues lets you route files from the PC to BSD TCP IP print queues per RFC 1179 on an LPD server For example you can route files to print queues on a UNIX host The LPR protocol writes to an LPD at the specified IP address LPR is used to submit jobs to LPD print queues and LPD manages the print queues You can request software with this option from Barr Systems n o 2 E a 3 G a a Fq oa This feature requires FTP Software s PC TCP kernel version 2 2 or later PC TCP provides the PC interface to the TCP IP network The number of TCP connections is limited only by the number of NET devi
505. r local host attached printing because the host implements SNA remote printing and local printing differently Specifically when files are sent to a local printer each carriage control stop can be used several times on one page When files are sent to a remote workstation each carriage control stop is limited to one instance per page FCB handling at the remote affects how FCBs should be defined at the host and might prevent you from using the FCBLOAD feature Z i E i E L L 522 F 3 Using FCBLOAD with HASP190 Local Carriage Control When you create FCBs for local host attached printing you can put carriage control stops 1 to 12 on any line and you can define each stop on more than one line on the page Remote Carriage Control When you create FCBs for remote printing you must define carriage control stop 1 as the first print line or top margin of the page When the printer encounters a 1 stop it advances to a new page and positions the print head at the first print line You can define carriage control stops 2 to 12 on subsequent lines of the page but you can use each stop only once per page Determining Whether You Can Use the Host FCBs If you change from local printing to remote printing FCBs are probably already defined at the host The RJE limitation will not be a problem for you if all of the FCBs you will use for remote printing use each carriage control stop only
506. r meanings are listed in the following table Table 13 1 Carriage Control Characters Carriage Control Character Action of characters before line is printed blank Space 1 line 0 Space 2 lines Space 3 lines Suppress space overprint line Skip to stop 1 usually advance to new page s Or v 5 2 mn 3 N Skip to stop 2 channel 2 Skip to stop 3 channel 3 Skip to stop 4 channel 4 Skip to stop 5 channel 5 Skip to stop 6 channel 6 Skip to stop 7 channel 7 Skip to stop 8 channel 8 Skip to stop 9 channel 9 Skip to stop A channel 10 Skip to stop B channel 11 Alwil lo lola fa lnm A lw lw Skip to stop C channel 12 Edit Forms Examples The following examples show you how to define several common forms including a standard form a form for printing checks a form that skips the paper perforation a two page form and one inch labels Example 1 Standard Form Many print applications produce general listings or reports that are printed on plain or standard paper A common name for the standard form is STD BARR RJE 221 If you use one of the automatic methods for mounting Barr forms you can use the STD form as a backup in case a form definition is omitted If the specified form is not in the table BARR RJE will load the STD form if you have defined it To define the standard form follow t
507. rames It is coded in binary as 01111110 flow control Mechanism to control the rate that data is sent to devices such as printers so that data is not sent faster than it can be accepted See also pacing and virtual route pacing formatted logon In SNA communications a logon message coded into fields including the remote name password LOGMODE table and APPLID frame In SNA communications a consecutive string of bits sent as a unit The frame begins with a flag followed by an address and control byte data and Cyclical Redundancy Check CRC and ends with a flag front end processor FEP A processor that relieves the host compu ter of certain processing tasks such as line control message handling code conversion and error control Examples include the 3725 and 3745 FTP File Transfer Protocol In TCP IP an application protocol used to transfer files to and from host computers FTP requires a user ID and perhaps a password to allow access to files on a remote host 538 Glossary system FTP assumes that TCP is the underlying protocol full duplex A communications link that allows for the simultaneous transmission of data in both directions in contrast to half duplex function keys The 40 key combinations to F10 c EL to FO CED to ER and to F10 on the left or top of the keyboard gateway A device that uses protocol conversion to connect dissimilar communications sys tems
508. ranslated to the appropriate coding system so that the graphic symbols can be viewed printed or written to disk Translation tables in the BARR RJE Installation Description control the translation of symbols between EBCDIC and ASCII When data is sent from the PC to the mainframe BARR RJE must translate the data from ASCII to EBCDIC When data from the mainframe is received by the PC the opposite translation from EBCDIC to ASCII must be made 910984 pue II9SVY 4 RJE 3270 Data translation for RJE sessions is different than data translation for 3270 sessions See your 3270 for RJE manual for information about 3270 data translation BARR RJE 489 FER Sending ASCII Data BARR YRJE translates from the ASCII to the EBCDIC character set when you send data to the mainframe Each ASCII line ends with the carriage return character BARR RJE discards line feed LF form feed FF and delete 7F characters before it sends the data Horizontal tab HT characters produce the standard spacing assumed by the IBM PC Section B 4 describes the ASCII to EBCDIC translation table BA Receiving ASCII Data The host computer sends EBCDIC files BARR RJE translates the data in each line from EBCDIC to ASCII Section B 5 describes the EBCDIC to ASCII translation tables Each line received from the host computer provides line feed and carriage control information as described in the following table Spacing information ASCII codes
509. re sessions EEE Monitor and Adapter Options Monitor Specify the type of monitor connected to your PC Default The software automatically determines if the monitor display is color or monochrome black and white from the current DOS mode setting CGA amp 5 a E i a Your monitor is compatible with the IBM Color Graphics Adapter CGA which has a low resolution color screen with 320 x 200 lines EGA Your monitor is compatible with the IBM Enhanced Graphics Adapter EGA which has a resolution of 640 x 350 lines VGA Your monitor is compatible with the IBM Video Graphics Array Adapter VGA which has a resolution of 640 x 480 lines Required for 132 column display Monochrome Your monitor has a two color display usually black and white Multiscan Your monitor has multiple scan rates that automatically adjust to the adapter scan rate PCs with built in VGA adapters require a multiscan monitor for example a NEC Multisync to display 132 characters Adapter Specify which type of PC video adapter you use with the monitor 200 11 2 Monitor and Adapter Options Default The software automatically determines if the adapter is a Monochrome CGA EGA or VGA Default is always a valid selection To use a larger screen size select the adapter type that matches your adapter from the following choices Everex EV 659 Paradise VGA Tseng EVA 480 VGA Wonder Gen
510. referred way to exit BARR RJE disconnects from the host after all files finish printing and current input files are completely sent When you select this option the following procedure automatically begins 1 BARR RJE sends the Request Disconnect command to the host 2 BARR RJE waits for all tasks including printing and receiving files to disk to complete Note If you are using the print spool you must drain the spool printer and wait for the current job to complete 3 Finally BARR RJE exits to DOS Disconnect Link Disconnects from the host without exiting the BARR RJE software You can use this option to continue operating the print spool when the host link is not active Exit to DOS abruptly BARR RJE abruptly terminates and exits to DOS It does not wait for the printer to finish Use this option only as a last resort Dedicated lines Some hosts might not recover from an abrupt disconnect The host operator might need to reset the line before you can connect again Restart program Immediately terminates BARR RJE without waiting for the printer to finish and then restarts BARR RJE Note If you automatically send files when you start BARR RJE these files will not be sent again when you use the restart option BARR RJE 337 N _ o gt eoj ps J amp m i 3 2 5 Connect link Reconnect to the host without restarting the software BARR RJE tries to make a connection and
511. rights and you may also have other rights which vary from state to state Some states do not allow limitations on how long an implied warranty lasts or exclusion or limitation of incidental or consequential damages therefore the limitations set forth in this agreement may not apply to you Copyright The Licensed Software is the sole and exclusive property of Barr Systems which is licensed and distributed by Barr Systems pursuant to a non exclusive software license agreement it is an unpublished work with all rights reserved and contains confidential information and trade secrets proprietary to Barr Systems Disassembly or decompilation is prohibited patents pending Licensee acknowledges and agrees that the Licensed Software is copy righted and that Licensee is not authorized to reproduce any copies of the Licensed Software nor allow others to reproduce any copies except in accordance with instructions in this manual Licensee further agrees that Licensee does not have and shall not gain any exclusive copyright rights with regard to the Licensed Software 2 2 5 Z S o 3 2 i 5 BARR RJE 529 Miscellaneous These definitions shall govern the use of terms in this agreement Barr Systems Inc a Florida corporation whose address is 4500 NW 27 Avenue Gainesville Florida 32606 7031 is the author and owner of the Licensed Software Single user workstation is defined to include any devi
512. rint Spool screen results in the use of the correct form definition from the printer For example this method is useful with Xerox laser printers that store forms in the printer File Attribute Descriptions This section describes the file attributes that display on the Print Spool screen and how they can affect the print spooling process You can change all the file attributes except size date and time You can view a list of all the attributes from the spool header with the View Header or View File commands as described later in this chapter See Appendix E for a complete list of file attributes and the methods you can use to set the value for each attribute State Current status of the file You can use this attribute to control which spool printer is selected to print a file o i i 72 pan E Q N Ready File can be selected for printing Hold File will not be selected for printing If only a portion of a file is received the software automati cally sets the file state to hold This prevents incomplete files from printing Other error conditions might also set the file state to hold 408 24 1 Managing Print Spooling Delete File will be deleted Error An error occurred while writing to the retain directory Verify that your spool and retain directories are on the same hard drive Retry When you direct files from the print spool to a NET device SPOOL1 NE
513. rint lines per form indicating the print area of each page LPI 6 The number of lines per inch that will be printed on the page CONTROL 00 An optional printer control string selector in hexadecimal It is an index to the Barr Printer Control Data table for the destination device Each LPT COM or NET device has a separate table as discussed in section 8 8 The control string associated with this index code is sent with the file to the printer LOCNAME A field used internally by the Barr software for locating a form overlay file JOBNAME j obname The eight character job name for the file COPIES 1 The number of copies to print If a value is not specified the number of copies is set to 1 Japeay joods Y ASCII ASA conversion flag Indicates that BARR RJE should convert ASA carriage control to machine carriage control for ASCII files so you can print them on S 370 channel printers Requires the PRINT370 option You can set this value with the options listed in Table E 1 or with the ASCII data with ASA carriage control option on the Assign Devices Options screen BARR RJE 509 E Spool Header FCBLOAD Indicates whether BARR RJE received FCB information from the host Used internally by the software PRIORITY 5 The file print priority Valid values are 0 to 9 where 9 is the highest priority STATE READY Indicates the file s spooling state Valid states are Hold or Ready CLASS 1 The spooling c
514. rinter as shown in Figure 9 3 Spool Printers FORM Spool 1 STD n Spool 2 CHECKS g he Spool Files FORM aJ _ a PC Printer 1 File 2 OTHER File 3 OTHER File 4 CHECKS 7 File 5 INVOICES Ao File 6 INVOICES e PC Printer 2 Figure 9 3 When a file s form and class match a spool printer s form and class the file prints In this example Spool Printer 1 routes File 1 to PC printer 1 and Spool Printer 2 routes File 4 to PC Printer 2 File attributes can originate from a variety of sources For a complete list of file attributes and the possible ways to set them see Appendix E You can preset spool printer attributes from the Printer Initialization screen and maintain them on the Print Spool screen You can assign spool printers to destination devices from the Assign Devices screen as described in section 10 7 BARR RJE 121 EFJ Checklist for Print Spool Setup To set up the print spool you must define the spool devices specify the flow of files to printers or other destination devices and assign file and printer selection criteria Follow these three steps to set up the print spool feature 1 Enter the Print Spool Description options discussed in the rest of this chapter 2 Assign source devices to write to the spool directory for example assign PR1 SPOOL from the Assign Devices screen See section 10 7 Assigning Spool as a Destination i o N o a i
515. rinter DIP switches or configuration data in the printer Incorrectly wired printer cable Inconsistent serial port baud rate Printer hardware error Incorrect settings in the Barr software The test file includes several test patterns to test various printer features The printer test printout describes the printer test patterns to help you evaluate test results XR Test the Printer from DOS Run the first test from DOS to confirm that the PC and printer communicate properly You can compare these test results to a second printer test you run from BARR RJE To run the test determine if the printer is attached to a parallel or serial port Then follow the directions below that correspond to your printer port 188 J9 Uld A Test Printer on Parallel Port LPT1 This example tests the printer on LPT1 Substitute the number of your parallel port 1 From the DOS prompt copy the PRINTER TST file to the PC parallel port with the DOS copy command For example copy c barr ref printer tst lpt1 BARR RJE 501 2 Review the printer test printout Compare the printed test patterns with the descriptions of how they should print to determine if the printer functions properly 3 Resolve any errors before you proceed to the next step in section D 2 Test Printer on Serial Port COM1 This example tests the printer on COM1 Substitute the number of your serial port 1 Use the DOS mode command to configure the serial po
516. rized to enter into it and agree to be bound by its terms and that it is the complete and exclusive statement of the agreement between the parties which supersedes all proposals oral or written S S E S 530 Warranty Information If any provision or portion thereof of this agreement shall be deemed invalid and or inoperative under any applicable statute or rule of law it is to that extent to be deemed omitted and shall have no effect on any other provisions of the agreement This agreement shall be construed and enforced in accordance with the laws of the State of Florida and is deemed entered into at Alachua County Florida by both parties 2 2 Z S i 3 2 i 5 BARR RJE 531 Notes S E S 532 Warranty Information Glossary ACK In bisynchronous communications a positive acknowledgment character used to indicate that a message was received correctly adapter Add on equipment you can plug into a PC to allow the PC to connect to another device ADLC Asynchronous data link analog Refers to data represented by a physical variable that varies in a continuous rather than discrete manner and is usually represented by an electrical signal ANSI American National Standards Institute Inc ANSI establishes standards for transmission codes and protocols application program Software t
517. rmat depends on the type of information the operator requests D F displays the number of special forms jobs and their job classes waiting to print at the operator s remote D Jnnnn displays information about a job or a range of jobs under the operator s jurisdiction If nnnn is a single number only job nnnn displays If nnnn is a range of numbers all jobs in that range display For example an operator can type D J1 32767 and receive a list of all jobs in the system under that operator s jurisdiction If a job is not printing make sure the job s criteria for example form or class matches the printer s criteria with the LJnnnn command D MRx message sends a message to the remote specified by x The message can contain up to 53 characters If x 0 the message goes to the host 2 computer console i D N Q y T displays the queued jobs where y describes the type of jobs to display For y substitute one of these parameters XEQ displays only jobs awaiting execution XEQc displays only jobs awaiting execution that have the job class specified by c PPU displays only jobs waiting for the printer or punch 464 A 1 JES2 Remote Commands HOLD displays jobs on hold OUT displays jobs awaiting output processing Job information and the percentage of spool use display D Q Q Y identical to D N except that only the number of jobs displays rather than the job names and other information
518. rms in the Installation Description you can use the Mount Forms command to manually mount a form See Chapter 13 for information about defining forms See Appendix F to learn more about how to mount forms automatically and obtain form information from the host i o a oS Wu 5 c gt s c co rr N Follow these basic steps to mount a form on a printer 1 From the Mount Forms screen select a form from the BARR RJE forms list 2 Mount the paper form and ready the printer 3 Notify BARR RJE that the form is mounted 350 21 6 Mount Forms Detailed instructions follow When you finish step 3 BARR RJE auto matically sends the Mount Forms and Start Printer commands to the printer 1 Select a form Begin by navigating to the Mount Forms screen Operation Command to Host Send Files to RD2 Advanced Quit Send Files to PROE Mount Forms Selectiont gt a From the Operation screen select Mount Forms Note If Mount Forms is not a selection on your screen verify that you defined forms in the BARR RJE Installation Description See Chapter 13 for more information Select form No form for PR1 STD CHECKS INVOICES I Scroll gt Selection t gt b Use the arrow keys to select a form and then press Enter P PR1 E PR1 Mount paper on PR1 using form STD then press any key Any key BARR RJE automatically se
519. rol to machine carriage control in an ASCII file so you can send it to an S 370 channel printer Requires the Barr PRINT370 option NO Do not convert ASA carriage control to machine carriage control YES Convert ASA carriage control to machine carriage control Conversion takes place when the spool sends the file to the printer N ol i gc m J p lt 5 Exit and save your changes a To exit the Spool Controls window press at any time or press while the last field is selected You return to the PRT menu while your changes to the options remain active Next you can save the active values to a control file BARR RJE 439 Directory of C BARR File Size Date Time File Size Date Time BARR CFG 14120 03 26 97 10 39 TEST CTR 120 03 26 97 14 51 SPOOLP EXE 177917 03 27 97 13 21 SPOOLP4 EXE 180205 03 27 97 10 43 PRT EXE 157290 03 27 97 10 02 START JOB 19 03 26 97 10 36 END JOB 18 03 26 97 10 36 JOB 15 03 26 97 10 37 SPOOL EXE 156413 03 26 97 11 23 SPOOL CTR 120 03 26 97 14 51 SCAP ASC 765 03 28 97 08 31 SCREEN CUT 2492 03 28 97 09 14 FD 328 03 28 97 11 06 MYLIST 15 03 28 97 11 48 OVERRIDE CTR 120 03 26 97 14 51 ALT 174 03 28 97 11 49 Spool File File Directory DOS Controls View File Quit b Select Controls Controls Modify controls Load controls Save controls c Select Save controls Save Controls Enter file SPOOL CTR Enter control file
520. rom the Installation Description screen select Startup Screen Notes Startup Screen Notes The following information is not necessary for BARR RJE to run although it is helpful to the user Use the following keys to move about the screen tl Enter the name of the central host computer CENTRAL HOST NAME o N 9 3 N o o o The following three lines of comments appear on the screen at startup Enter the name and phone numbers of your contacts Call 555 1000 for modem connection to central host computer Call 555 4210 for central host operator Call John Smith at 555 2345 for problems with PC Enter character The first few sentences on this screen explain how to enter startup information 2 Enter the name of your host computer inside the brackets The name you enter displays on the first line of the Operation screen when you start BARR RJE and continues to display during program operation For more information on the Operation screen see the Startup Instructions chapter It is especially helpful to display the host name if you connect to different hosts with different Barr configuration files 3 Inside the box enter phone numbers for help desks or contact persons the PC operator should contact if communication problems occur These numbers display below the BARR RJE Communication Scope and Status Line when you start the program BARR RJE 2
521. roup s destination must match the device s route code R If you specify multiple route codes JES considers them to be in priority order and prefers a match with the first route code After the slash the output group s destination must match the device s route code but if you specify multiple route codes JES does not prioritize them PRM process mode Before the slash the output group s process mode must match the device s process mode PRMODE If you specify multiple process modes JES considers them to be in priority order After the slash the output group s process mode must match the device s process mode but if you specify more than one mode JES does not prioritize them CA D c lt LIM limit Before the slash the amount of output generated by an output group must be within the limits set for the device JES checks page limits if the dataset is in page mode and record limits if 478 A 1 JES2 Remote Commands the dataset is in line mode After the slash the limit is preferred but not necessary F forms Before the slash the forms specification of the output group and output device must match After the slash matching is preferred but not necessary If the two do not match a setup message HASP190 will be sent FCB Before the slash the output group s FCB must match the output device s FCB After the slash a setup message HASP190 will be sen
522. rr Host Definition Guide For more information about bind data see the IBM publication SNA Sessions between Logical Units an S a D S a E E o m N Table 23 2 describes each byte displayed in the bind data 390 23 5 Bind Data Table 23 2 Bind Data Description Byte Values Description LOGMODE 0 31 Bind command code 1 01 Activation code is non negotiable 2 03 FM profile FMPROF X 03 3 03 TS profile TSPROF X 03 4 A3 Primary LU protocol PRIPROT X A3 compression on receive Al Primary LU protocol PRIPROT X A1 no compression on receive B3 Primary LU protocol PRIPROT X B3 compression on receive B1 Primary LU protocol PRIPROT X B1 no compression on receive 5 A3 Secondary LU protocol SECPROT K A3 compression on send Al Secondary LU protocol SECPROT X A1 no compression on send B3 Secondary LU protocol SECPROT X B3 compression on send B1 Secondary LU protocol SECPROT X B1 no compression on send 6 70 Common LU protocol COMPROT X 7080 7 80 8 07 Barr to Controller pacing SSNDPAC 7 9 07 Controller to Barr pacing SRCVPAC 7 PACING 7 10 85 Input buffer size 256 RUSIZES X 8585 86 Input buffer size 512 RUSIZES X 8686 87 Input buffer size 1024 RUSIZES X 8787 F3 Input buffer size 120 RUSIZES X F3F3 BARR RJE 391 N oo o Ej 3 o K Ss an o na an o S a D S a E
523. rride values Filename Jobname File name and job name are used as the match criteria Entries in the FAT are applied to spool files when the file name and job name of a file match a table entry This choice allows you to override the value of the form name in the file With this selection the column headers of the File Attribute Table screen for an internal FAT appear as follows Filename Jobname Form State Class Prty Copies Disposition The Form through Disposition fields are used as override values Filename FCBname File name and FCB name are used as the match criteria Entries in the FAT are applied to spool files when the file name and FCB name of a file match a table entry This choice allows you to override the value of the form name in the file With this selection the column headers of the File Attribute Table screen for an internal FAT appear as follows Filename FCBname Form State Class Prty Copies Disposition The Form through Disposition fields are used as override values Type of FAT table Choose whether to maintain the FAT from the Barr software Installation Description or in a separate file internal Maintain the FAT from the Installation Description The internal File Attribute Table screen displays when you finish with the File Attribute Table Options FAT screen and press Enter You can view and edit the table from the Installation Description You can make
524. rs data files on the punch to the PC workstation These files do not include carriage control characters and usually are not printed Instead these files can be processed by programs on the PC Historically you received data to a card punch that recorded data on 80 column punched cards PC Printers The PC workstation running BARR RJE is compatible with dot matrix nonimpact laser and line band printers You can choose the type of printer according to your printing needs You can attach up to seven parallel interface and serial interface printers to the PC through the parallel or serial ports Barr Systems also offers special support for printers that use the Dataproducts Interface requires BARR DPI and the IBM S 370 channel interface requires PRINT370 You can request information about configuring peripheral devices to work with BARR RJE from Barr Systems The configuration information includes switch settings and control data for various printers plotters and modems The rest of this section discusses the parallel and serial interfaces and how they work with BARR RJE Parallel Ports The PC parallel port transfers all eight bits of a data byte simultaneously By sending each data bit across one of eight wires each data bit travels side by side with the other bits This simultaneous data transmission is faster than the serial port transmission rate The parallel adapter interface standard also known as the Centronics Printer I
525. rs to files before it copies them to the print spool The control file specifies spool instructions such as the disposition of the file after printing the form name to assign to the files and printer commands like lines per inch lines per form and print lines per form The default control file SPOOL CTR is included with the Barr reference files You can modify the default control file or create additional control files as needed When you create additional control files use CTR as the file name extension to make the files easier to identify You can use the PRT program or an ASCII editor to maintain control files Maintain Control Files Interactively To maintain control files with the PRT utility follow these basic steps Run the PRT utility From the PRT screen select Controls From the Controls menu select Modify Controls On the Spool Control screen change control file options as needed gt D e c a o a 7 wo N na A UU N e Exit and save your changes Detailed instructions for each of these steps follow 1 Run the PRT utility gt Type PRT at the DOS prompt The PRT screen displays a two column listing of files in the current directory 434 25 2 Create Control Files Directory of C BARR File Size Date Time File Size Date Time BARR CFG 14120 03 26 97 10 39 TEST CTR 120 03 26 97 14 51 SPOOLP EXE 177917 03 27 97 13 21 SPOOLP4 EXE 180205 03 27 97 10 43 PRT EXE 1572
526. rt Then copy the file PRINTER TST to the serial port via the DOS copy command For example mode com1 9600 n 8 1 copy c barr ref printer tst com1 Note BARR RJE supports XON XOFF flow control which prevents character loss during this test 2 Review the printer test printout Compare the printed test patterns with the descriptions of how they should print to determine if the printer functions properly 3 Resolve any errors before you proceed to the next step in section D 2 LRA Test the Printer from BARR RJE Run the test from BARR RJE to verify that you correctly configured BARR RJE to drive the printer Printer test performance from BARR RJE is dramatically better than directly from DOS The Barr software drives the printer more efficiently than DOS and uses printer features DOS does not support Send Test File N s A a Send the test file to the printer via the Barr Send Files command as follows 1 Start the Barr software 2 From the BARR RJE Operation screen select Advanced and then Assign Devices 502 D 2 Test the Printer from BARR RJE 3 Select the source device SEND1 4 Assign SEND1 to the desired LPT1 LPT2 LPT3 COM1 COM2 COM3 or COM4 printer destination The following screen shows SEND1 assigned to LPT1 Assign Devices SEND1 LPT1 SEND2 SCREEN KEYBOARD gt COMMAND CON SCREEN LOG NUL PR1 LPT1 PU1 SUSPEND Select SOURCE DESTINATION Selection tJ
527. rt 65 Interrupts turn off serial port 67 IP address 82 IPDS printers 31 IRQ 262 Italian character set 277 J Japanese English character set 277 JCL See Job Control Language JECL 285 JES2 9 17 publications 4 JES2 commands 24 459 printer 242 printer forms 240 sending at startup 258 JES3 9 17 LDENS parameter 524 publications 5 JES3 commands 481 printer forms 241 Job banner page See Banner page Job control JES2 459 461 JES3 481 Job Control Language JCL DCB description 183 form name 218 job name and form name in 169 LAN connections 111 record format 181 serial port input header 66 104 105 Job Entry Control Language JECL 285 Job header 407 Job name ending of file name is 163 167 168 See also File attributes form overlay file 289 from file 190 HASP190 163 286 521 JCL 169 OUTPUT statement 187 PDIR 516 SETUPHDR 283 spool header 509 Job queue name See Print queue name Job separator 411 files 193 identifier byte 511 punch cards 192 Job cancel on serial port 70 K Keyboard entry 35 native language 276 KEYBOARD device 153 154 Kodak Komstar 32 Optistar 32 L LAN 24 30 support program 2 LAN adapter 2 publications 6 LAN Connection Options screen 109 LAN connection retain directory 110 date and time for files 110 duplicate file names 167 retain period 110 LAN Connection screen 113 LAN connections 24 78 107 114 321 send command 110 activity log 354 error handling 111 exa
528. rted to EBCDIC control characters as documented in section B 4 When data is received to the PC from the mainframe computer EBCDIC control characters 00 to 3F are converted to ASCII control characters as documented in section B 5 The translation tables in the software are altered if you select this option You must select Translate control codes to Control codes before you use the Edit translation tables option A message indicating your selection displays on the lower half of the screen The translation tables have been modified to translate control codes to control codes 274 18 1 ASCII and EBCDIC Translation Tables You can select Edit translation tables to see these changes or to make additional changes See section 18 3 Reader Control for additional options that affect the ASCII to EBCDIC translation of the ASCII characters 89 8A 8C 8D 9A FF and 7F Translate control codes to Question marks Use this selection if you do not want control codes that are embed ded in the data to be converted from ASCII to EBCDIC or vice versa This is the default choice Normally control codes are not embedded in the data records This option is useful if you want to flag any control codes that occur in the data Note Do not confuse control codes embedded in the data with control codes that precede data records Control codes that precede data records are processed differently and are not changed by the translation tables Tra
529. rtup You can enter startup commands to drain or start the printer set a printer form or perform other initial operations on the BARR RJE Commands Sent at Startup screen When BARR RIJE starts it sends the stored commands to the host computer The PC operator no longer has to manually issue the same set of commands each time BARR RJE starts EEX Commands Sent at Startup Screen To enter and save commands you want BARR RJE to automatically send to the host computer at startup follow these steps gt From the Installation Description menu select Commands Sent at Startup b a a 2 s O 3 D E 2 a Commands Sent at Startup 00000000011111111112222222222333333333344444444445555555555666666666677777777778 12345678901234567890123456789012345678901234567890123456789012345678901234567890 Enter character When you enter commands follow these guidelines a Use the and 9 arrow keys to move along an entry line Use the and Q arrow keys to move to another line You can enter up to 80 characters on each command entry line Character positions are numbered from 01 to 80 under the entry lines You can enter several commands on each line if you separate them with a vertical bar When you finish entering commands press to store your changes and return to the Installation Description menu BARR RJE 257 A 3 E E o 2 E
530. ry If the first and second matching entries both change the same attribute for example the number of copies the second matching entry replaces the value from the first matching entry Default Entry You can use the default line at the bottom of the table to supply default attributes for any file whose file name or form name does not appear in the table The default line begins with the word DEFAULT It can provide values for most files and you can use individual table entries to specify exceptions for a few files The default line is ignored if you do not enter any override values in it Blank Values Only the override attributes that have values are applied to files Where blank override attributes appear in the table the value from the file if any is used 138 9 5 File Attribute Table FAT FAT Criteria Follow these guidelines when you enter match and override fields for an internal table or external FAT file Match Criteria The first two fields in the table are file match criteria You can specify one field or both fields depending on how you want the override attributes to be applied Which two match criteria you see depends on your selection for the Match FAT entries using option Filename In the table entry you can specify the complete file name or use DOS wildcards If you specify the complete file name it must be an exact match of the file s full name including the file extension for the software to app
531. s End users need two types of communications service Remote job entry for submitting jobs and RJE printers to print reports ow lt i a 2 m 5 i 3 o 5 E3 a 3270 interactive terminals to communicate with mainframe applications and 3270 printers The end user workstations communicate with mainframe application software to perform tasks For example the BARR RJE workstation communicates with the RJE system for remote printing The Barr RJE 3270 program communicates with interactive 3270 programs for data entry RJE RJE is comprised of two parts workstations and the mainframe system Workstations RJE workstations print reports at remote sites send large files directly into the job entry system JES and control the status of mainframe jobs An RJE workstation can be an IBM 3777 3 System 36 running the Multiple Session RJE program or a PC running BARR RJE Mainframe System A mainframe RJE system manages job input and report and file output for remote sites BARR RJE is compatible with host computers that support the SNA Multiple Session RJE communications protocol as the following IBM systems do a MVS JES2 a MVS JES3 a VSE POWER a VM RSCS a VS1 RES The RJE system communicates with VTAM the universal SNA control program BARR RJE 17 3270 Workstations and Applications The IBM mainframe environment includes 3270 workstations and applications Workstations pe o
532. s Selection t gt Use the command menu at the bottom of the Operation screen to perform communications tasks Command to Host Communicate with the host RJE system through the PC console You can send commands to select files to print recover from printer S errors cancel output mount forms and locate jobs on the host See 5 section 21 2 a w Quit S Disconnect from the host reconnect to the host exit BARR RJE or restart BARR RJE See section 21 3 N Send Files Transfer PC files to another device Two Send Files commands allow you to transfer files See section 21 4 Advanced Move between BARR RJE sessions assign devices or diagnose problems See section 21 5 Mount Forms Control the printing of special forms See section 21 6 Note The Mount Forms option appears on your screen only if you define printer forms in the Barr Edit Forms table See Chapter 13 334 21 1 Command Menu AFJ Command to Host Use the Command to Host option to send commands to the host Appendix A describes the most common JES2 JES3 and VSE POWER commands 1 From the Operation screen select Command to Host F1 Display all jobs F2 Status of remote F3 Display forms queue F4 Display all output F5 Drain printer 1 F6 Interrupt printer 1 F7 Start printer 1 F8 Restart printer 1 F9 Delete time stamp FO Backspace 2 pages Esc Enter gt PgUp Col 1 2 Type a comm
533. s You can define function keys that prompt you to supply parameters when you press the key This feature allows you to define fewer keys because you can use a single key to issue similar commands Using the Prompt When you define the function key substitute a question mark for the value you want to supply later For example you can define to print 1040 forms on the print stream of your choice PR instead of a specific printer PR1 When you press the function key during program operation the command displays on the Command to Host edit line At each occurrence of a in the command the display pauses and a blinking prompts you to supply the missing parameter In this example you would supply the printer number When you press Enter the software sends the completed command to the host gt x i oO Lu a You can include more than one prompt in a function key definition When you use the function key press each time you respond to a prompt You can include prompts anywhere in the command line for the function key definition JES3 Because the is a standard character in JES3 commands you cannot use a single as a command line prompt in the Barr software with JES3 You must use a double question mark in the function key definitions The software can then distinguish between the JES3 command character and the Barr prompt Using a to Indicate a Missing Parameter
534. s usually during unattended operation If the previous option Use Barr FCBLOAD is set to Yes the only valid choice is HASP190 FCBNAME The other selections are ignored See Appendix F Form Information Sources for additional details about the available options for obtaining form information Appendix F will help you determine which feature best meets your printing needs SETUP PDIR FORMNAME SETUP PDIR FCBNAME Default Depending on your selection the form name or FCB name provided by the SETUPHDR PDIR record is used to automatically mount the printer form This feature is supported by most host operating systems With either SETUP PDIR choice you must define printer forms in the Barr software to supply format information The information from the PDIR record is stored in the Barr spool header and can be displayed on the Print Spool screen oo z im kzi i gt an Both SETUP PDIR selections provide the same information form name FCB name job name UCS Train name and copies but your choice determines how you must name the forms in the Edit Forms table If you select SETUP PDIR FORMNAME forms must be named to match the form name supplied by the message If you select SETUP PDIR FCBNAME forms must be named to match the FCB name provided by the message See Chapter 13 Printer Forms for more information about defining forms During software operation if no matching form is found in the Barr
535. s The banner page produced by BARR RJE is similar to Novell banner pages but the banner name and file name at the top of the banner page are in regular sized type rather than oversized type Novell Queue Devices Menu gt From the Devices and Printers menu select NOVELL Queues The following screen displays 114 8 11 NOVELL Queue Devices Novell Queue Devices NW_QUE1 Delete NW_QUE2 Delete NW_QUE3 Delete NW_QUE4 Delete Queue Server Options Escape Selection t oo i D S o D a 2 Ss ies me Ss a a NW_QUE1 NW_QUE4 Select the Novell NetWare queue to use When you press Enter another screen displays Source Queue Options later in this section describes these options Queue Server Options The Barr software acts as a network queue server When you press Enter another screen displays Queue Server Options later in this section describes these options Source Queue Options When you select an NW_QUE device from the screen the Source Queue Options screen displays For example the following screen displays if you select NW_QUE1 Source Queue Options NW_QUE1 Use this source device No File server of queue SERVER Queue to service BARR_QUEUE Choice The same options display for each NW_QUE device BARR RJE 115 Use this source device Select whether to enable the device No Default Disable the device
536. s A This display tells the operators which forms are waiting so they can load the appropriate paper and release the jobs with that form and class To release the jobs with the CTST form the operator can set the printer for this form and the two different classes by using the command T PR1 F CTST Q AB If there are no jobs waiting JES returns the message NO OUTPUT QUEUED BARR RJE 467 DJ1 9999 The DJ1 32767 command is sometimes useful In the Barr software function key comes predefined with DJ1 9999 but most systems have newer releases of JES2 that support job numbers up to 32767 This command displays the status of any jobs submitted from this remote no matter what destination the output is bound for Here is a sample of the JES2 response to the command DJ1 9999 14 10 53 HASP610 JOB S NOT FOUND 14 10 56 DJ1 32767 14 11 02 J0B16250 HASP608 CCTEST AWAITING HARDCOPY PRIO 1 ANY 14 11 05 JOB16252 HASP608 NF AWAITING HARDCOPY PRIO 1 ANY 14 11 06 If jobs are listed but not printing you need to find out why The job criteria that is form and class might not match the criteria on the printer Note the job number in the DF listing and then use the LJnnnn ALL command to obtain more details about a specific job The following example uses the job number 16250 from the CCTEST job above LJ16250 ALL 14 29 03 JOB16250 HASP686 OUTPUT CCTEST 14 29 07 JOB16250 HASP686 OU
537. s a preferred gateway selection order use the priority method With the priority method the connection to the prefer red gateway is attempted first Netview Alerts Choose whether to enable the Operator Alerts feature of the mainframe NetView program NetView is a tool for enhanced network management and is described in Chapter 23 Communi cations Diagnostics This feature is most often used for software connecting through the BARR GATEWAY but can be used for standalone products as well No Default NetView Operator Alerts are not enabled 300 18 4 Modem and Line Control Yes Enable NetView Operator Alerts which allows the PC opera tor to send alert messages to the host computer NetView also must be enabled at the host EE Restart Actions The Restart Actions screen lets you select what action the software will take when a restart condition occurs gt From the Tuning and Global Options screen select Restart Actions Restart Actions Disconnect if idle No Idle time period 30 seconds Exit from program after disconnect Yes Reconnect periodically No_ Reconnect time interval Enable FNA Termination Sequence No Choice ob oo z im kzi i 5 a Disconnect if idle Choose whether the software will automatically disconnect from the host computer if the communications line becomes idle The line becomes idle when no data or messages are being tran
538. s are Novell Print Queue Device driver and TCP IP LPR UNIX Print Queue When you press Enter additional information displays on the second half of the screen See Network Printer Options later in this section for a description of these options Choose printer type You must choose the type of printer to use When you select this option a list of printers displays Section 8 6 describes the printer choices After you make a selection your choice displays on the NET Devices screen next to the device name BARR RJE 75 Miscellaneous printer options Several options affect printing For a description of these options see Miscellaneous Printer Options for NET Devices later in this section For a description of other options that affect printing see section 18 2 Tuning and Global Options Printer Control Printer control data Printer control data allows you to send control codes to the printer such as commands to set the lines per form and lines per inch or commands to reset the printer You can use printer control data alone or with Barr printer forms For network printers printer control data has a special function For more information see Printer Control Data for Network Printers later in this section n o 2 E a 3 G a a Fq oa Escape This option appears twice on the screen Select Escape or press the key to return to the Devices and Printers menu Network Printer Options
539. s section illustrate these methods Chapter 26 describes how to call BARR RJE from an application program Note 1 If you use print spooling or a LAN connection and you define the corresponding directory on your local PC drive execute the DOS share command to load file sharing support before you start BARR RJE Note 2 If keystrokes cause communications errors as described in Chapter 22 use the TSR command bios_key to eliminate the problem before you start BARR RJE From the BARR RJE Installation Description Screen Starting BARR RJE from the Installation Description screen allows you to change the software configuration 1 If you are not already on the Installation Description screen enter the following command at the DOS prompt barrsnar i BARR RJE 321 2 Change your BARR RJE configuration as needed Chapter 6 describes how to change your BARR RJE configuration 3 Exit the Installation screens and save your changes From the Installation Description screen select Exit and Save Changes 4 To run BARR RJE select Begin Communications at Operation screen from the Exit Options screen From the DOS Prompt Starting BARR RJE from the DOS prompt uses the existing configuration gt From a DOS prompt enter the following command barrsnar When You Power on the PC Starting BARR RJE when you power on the PC uses the existing configuration gt Add the startup command C BARR BARRSNAR to your AUTOEXEC BAT
540. s to group separate spool files that originated from the same host file A host file containing multiple outputs can be split into several files at PDIR occurrences The group code indicates that the software should send the indivi dual files to the same printer and it indicates the correct print order The first four characters form a unique file identifier assigned by the Barr software to indicate which spool files came from the same host file The last two digits show the sequential order in which the spool files were created and thus the order in which they should print BARR RJE S11 Japeay joods E Spool Header For example in the group code D6C101 D6C1 is the host file identifier and 01 is the file number CARRIAGE CONTROL STOPS Carriage control characters or stops are used to quickly advance the paper Each print line can contain only one carriage control stop Carriage control stops come from the host FCBLOAD feature or from the Barr Edit Forms feature The stops shown in the header are for ASCII line printers Files in S 370 format contain a separate FCB record 00000FB5 Fast reprint file offset Maintained internally by BARR RJE if you enable the Save fast reprint repositioning information option on the Print Spool Description s Advanced Spool Options screen If printing halts the software records where it left off The field remains blank until printing halts It resets to blank when printing resumes W
541. s to see if LPT1 is busy If the destination device is available the software writes the file to LPT1 and then automatically searches for another source device that is directed to the same destination At the same time the software can be directing other print punch and reader streams to other destinations BARR RJE 193 Example 1 PR1 and PU1 Share a Laser Printer Mainframe computers can produce print output on a print stream and plot output on a punch stream Some printers such as the QMS Lasergrafix can accept both print and plot data which allows the printer to be shared by both the print and punch source devices In this example assume a printer that supports both print and plot data is attached to your PC s LPT1 port You will assign both PR2 and PU1 to write to that printer Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD gt COMMAND CON SCREEN LOG NUL PR1 SPOOL PR2 SUSPEND PU1 SUSPEND SPOOL1 LPT1 4 2 gt 7 i K Continue Escape Receive mode Options Help 1 From the Assign Devices screen select the source device PR2 and assign it to LPT1 2 Select the source PU1 and assign it to the destination LPT1 The new assignments display on the screen Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD gt COMMAND CON SCREEN LOG NUL PR1 SPOOL PR2 LPT1 PU1 LPT1 SPOOLI LPT1 Continue Escape Receive mode Options Help With this assignment t
542. s to the mainframe the remote goes into Normal Response Mode Snrm on the Communication Scope and data communications begin Characters on the Communication Scope reflect activity between the PC and mainframe SDLC Scope Characters Tables 22 2 and 22 3 list Communication Scope characters for SDLC and X 25 connections 364 22 1 Dial Up Scope Characters Table 22 2 SDLC and X 25 Scope Characters Characters Description Notes 0 7 Information Frame number frame Disc Disconnect Host sends Disc to force remote into Normal Disconnect Mode Dm Disconnected When the remote is in Normal Disconnect mode Mode and the host sends frames the remote cannot process the remote sends Dm to request an Snrm Should only occur when program restarts Frmr Frame reject A frame was not formatted correctly Should never occur Rej Reject Sender of the Rej has received an information frame out of sequence and is asking for it to be sent again Only used for full duplex communications Rnr Receive not Sender is unable to receive any information ready frames Try increasing Memory allocated for buffers to 400 000 See section 18 6 Trace and Memory Options for more information Rr Receive Sender is ready to receive information frames ready During idle periods Rr messages bounce back and forth Extra Rr messages could indicate that the Barr software is set for full duplex DATMODE FULL but the host
543. save mode set this value to 0 The screen will display for one second and then go blank To view the software screens for more than one second you must hold the Shift Ctrl or Alt key The screen displays until you release the key To disable screen save mode set this value to 9999 The screen saver will not activate The screen save feature might not work with all display adapters The IBM monochrome IBM CGA and IBM PS 2 VGA adapters support the screen save feature The IBM EGA adapter does not support this feature Password for screen lock Fast You can lock the screen to prevent unauthorized users from accessing the Barr software If you specify a password in this field you can press to clear and lock the screen during software operation To reactivate the display press a key and then enter your password at the Enter your password prompt The password you enter in this field will be saved in encrypted form To prevent unauthorized users from viewing the password from the Installation Description you also should set Disable Installation Description to Yes If you leave the password blank you can use as an instant screen saver To activate the screen press a key and then press at the Enter your password prompt scroll used on CGA color monitor adapter Choose whether to use fast screen scrolling for CGA color display adapters 308 18 7 Display and Disk Options No Default The screen blinks each time n
544. sequence is not correct you might not be able to reconnect to the mainframe No Default Do not use the FNA termination sequence Yes Enable the FNA termination sequence FNA software does not handle the termination sequence the same way as IBM SNA software The Trace and Memory Options screen contains a variety of options that affect software operation The first two options on this screen for alloca ting PC memory are the most significant options gt From the Tuning and Global Options screen select Trace and Memory Options oo z im kzi i gt a Trace and Memory Options Memory allocated for buffers 100000 Extended memory allocated for buffers 0 Kbytes Line trace buffer size 16000 Line trace format full Test mode No Enter number Memory allocated for buffers Specify the amount of PC conventional memory measured in bytes that BARR RJE can allocate for buffers During software operation BARR RJE uses memory buffers for temporary data storage Each software feature has individual memory requirements so the amount BARR RJE 303 of memory required to operate BARR RJE depends on which features you enable in the Installation Description The value for Memory allocated for buffers does not include the amount of memory required to load the software or use the BARR RJE DOS session The default value depends on the software options you purchased
545. sferred This feature is useful for unattended operation or if you use delayed communications startup It can be used to avoid communications charges when there is no activity on the line During attended operation you can disconnect from the host by selecting Quit on the Operation screen See section 21 3 for more information about the options on the Quit menu No Default The software does not disconnect from the host computer when the communications line is idle Yes The software disconnects from the host computer after the specified Idle time period Idle time period Specify the period of time in seconds for which the line must remain idle before the software will disconnect The default value is BARR RJE 301 30 seconds This option is valid only if Disconnect if idle is set to Yes Exit from program after disconnect Specify whether BARR RJE exits after it disconnects from the host computer or whether other software features continue to operate This option is valid only if Disconnect if idle is set to Yes Yes Default The software exits to DOS after the idle time period is exceeded If both Disconnect if idle and Exit from program after disconnect are set to Yes protocol connection must be completed within 90 seconds of BARR RJE startup If a successful protocol connection is not made in 90 seconds the software exits to DOS No After disconnecting from the host the software continues to operate This allows
546. shown on the right side of each column The characters on the right side are the ones you can modify a Use the and keys to move up and down the columns on the screen To edit an entry place the cursor on the entry and type over the translation When you finish making entries to a table press to store your changes and advance to the next screen a If you want to abandon your changes for a table press to return to the ASCII and EBCDIC Translation Tables menu BARR RJE 279 Assign Translation Tables to Devices Assign an EBCDIC to ASCII table for each print or punch stream For each device choose Table one or Table two Assign Translation Tables to Devices PR1 Table one PUL Table one Choice gt Use the arrow keys to select a device Then use the 4 and keys to select Table one or Table two for each device RJE 3270 You can change the EBCDIC to ASCII translation table assignment for a 3270 print stream PR_1 to PR_4 The 3270 terminal devices do not display on this screen because you cannot change translation table assignments for 3270 terminal emulation ASCII to EBCDIC Table Two and EBCDIC to ASCII Table Two are automatically used for 3270 display emulation a i A i o ya EEF Printer Control You can use printer control options to specify additional features that affect print output including printer forms FCBs an
547. sion is performed This choice is useful when you receive 7 bit data with a parity bit of 1 for all bytes Usually this type of data is received on the serial COM port No Read the characters 89 8A 8C 8D 9A and FF as data These characters are not removed and are converted to EBCDIC before being sent to the host computer You can change the translation for these characters by using the ASCII to EBCDIC BARR RJE 293 table described in section 18 1 You can use the extended character set to conform to native languages Strip ASCII delete characters 7F from file Choose whether the ASCII 7F DEL character should be removed from the file before files are sent to the host computer Yes Default Remove the ASCII delete characters hexadecimal 7F when you send ASCII files This choice is useful when you receive files on the serial port Sometimes files are padded with 7F characters after the end of the data No Retain ASCII delete characters when you send ASCII files EEX Modem and Line Control Modem and line control options affect communications Most of these options are used to correct communication problems and should not be changed unless you encounter a problem gt From the Tuning and Global Options screen select Modem and Line Control a i 2 So o r Modem and Line Control Start communications at time _ Communication role Remote Minimum number of LUs 2 Ma
548. splay and print order with the Sort command described later in this chapter If the attributes for more than one file match the spool criteria the file with the highest priority is selected first Additionally a file that has already been received is selected before a file that is still being received As soon as a file is selected printing begins While a file prints its file name displays at the top of the screen next to the printer on which it prints Additionally the file state is updated in the file list i a Printer File State Form Class Prty Copies Size Units Status 5 LPT1 TAX1040 Printing 1040 1 5 1 284 415 busy aa LPT2 Ready LABELS 2 0 busy Date Time CHECKS CK501 1 0 1 1998 1 24 97 10 35 D PRICES Hold LABELS 2 3 2 4840 1 24 97 10 44 EA LPT1 TAX1040 Printing 1040 1 5 1 5180 1 24 97 10 35 S INVOICES INV99 2 5 8 3262 1 24 97 10 36 Printers Sort t PgUp Help Files Check Spool PgDn Escape Restore In this example the TAX1040 file is printing on LPT1 In the spool printer list TAX1040 displays in the file column In the file list Printing displays as the file s state You can use the Printers and Files commands to set the file and printer attributes that control print spooling as described in the rest of this chapter BARR RJE 405 Printer Attributes Printer attributes reflect the spool printer s status and control which files are selected for printing You can change ea
549. sponse to the setup message For JES2 the start command usually is PRn For VSE POWER the start command usually is GO LST 238 13 5 Printer Forms Commands Sent to Host If you do not use the JES2 HASP190 message or the VSE POWER 1Q40A message you can leave this line blank Note You can enter only one command on this line Unlike lines 1 and 2 line 3 does not support multiple commands separated by vertical bars Entering Command Strings Follow these guidelines when you enter command strings Substitute a lowercase n for the RJE printer number BARR RJE automatically replaces the n with the actual RJE printer number a Use a series of eight lowercase fs to represent the form name BARR RJE automatically replaces the ffffffff string with the selected form name a If you enter more than one command on line 1 or 2 use a vertical bar to separate the commands m You can use a character in the command to prompt you to enter information later When a form is mounted the command displays on the Command to Host entry line and you are prompted to enter the missing parameters This is the same feature you can use for function key definitions described in section 14 4 If you do not use forms control commands you blank out the commands on these lines with the Spacebar Printer Command Examples The following examples show common printer commands for MVS JES2 and MVS JES3 Example 1 Commands for MVS JE
550. spool directory If you do not specify a file name the source file name is used PRT adds the spool file name to the spool directory path to form the complete path name The file name extension consists of a period followed by up to three characters You can specify a file name extension or BARR RJE can assign an extension If the file name is followed by only a period a blank extension is implied If no period follows the file name then a numeric extension automatically is assigned BARR RJE searches the directory for any files with that file name 436 25 2 Create Control Files If it finds a file with that name the software assigns the numeric extension n 1 where n is the highest extension found If it finds a file without a numeric extension it assigns extension 001 For an example of the automatic naming sequence see File Name Extensions in section 10 5 Copies Number of copies of the file to print Priority Indicates the print priority Values range from 0 to 9 where 9 is the highest priority Class Spooling class Allows similar files to be grouped BARR RJE printers can process up to five classes at once You can direct a file to a particular printer by setting the file class to a value assigned to only one printer State Spooling state Choices are READY and HOLD If the file state is READY BARR RJE prints the file with no operator intervention Files with a HOLD state will not be printed until the stat
551. ss to save your settings an o S a D S a E E o m N 3 Recreate the problem Recreate the problem during the line trace If the problem involves receiving a file for example a file is not printing or is printing incorrectly you need to receive the file during the line trace While the line trace is on you might see status messages such as CON has begun CON has ended and PR1 has begun 4 Send the file to Barr Systems You need to send two files to Barr Technical Support Copy the line trace file see the sample below usually called DUMP and the received file to disk with a unique file name Then send the disk or the file to Barr Systems See the Contacting Barr Systems Electronically booklet for more information about sending disks or files to Barr Systems 388 23 4 Line Trace Version 97A3 gt ACTPU 2D 00 00 00 9D_3D 6B 80 00 11 02 01 05 00 00 00 00 01 lt ACTPU 2D 00 00 00 9D_3D EB 80 00 11 11 40 40 40 40 40 40 40 40 00 00 07 01 00 00 00 00 00 00 gt NMVT 2C 00 00 00 00_01 0B 80 00 41 03 8D 00 00 00 00 00 00 21 80 80 04 92 88 00 19 94 ED 00 kh m EC 00 00 00 01 00 00 00 00 00 00 00 04 00 OA 00 14 00 32 00 22 64 lt NMVT 2C 00 00 00 00_01 8F 90 00 10 03 00 00 41 03 8D 2 gt ACTLU 2D 00 02 00 9D_40 6B 80 00 0D 02 01 lt ACTLU 2D 00 00 02 9D_40 EB 80 00 0D 01 01 00 85 00 00 00 OC OE 03 00 01 00 00 00 40 40 40 40 e 40 40 40 40 gt ACT
552. ssions 1 to 4 are 3270 sessions These selections are valid only if you have RJE 3270 software GATE The GATE session is valid only for BARR GATEWAY software Ignore this selection for BARR RJE a i A i o r TAPE The TAPE session for the BARR TAPE option has not been implemented Hot key uses This option allows you to use an alternate hot key to change sessions Choices are Ctrl Alt Default Ctrl shift Alt Shift 312 18 8 Session and Security Options EEX Miscellaneous Options These miscellaneous options affect BARR RJE operation gt From the Tuning and Global Options screen select Miscellaneous Options Miscellaneous Options Variable length record delimiter 4F Disable Waiting for Processes to Complete before exiting No Enter hex number Variable length record delimiter If you use the Variable ASCII lines receive mode you can specify which character to use for the record delimiter Specify the hexadecimal value of the character The default character is the vertical bar represented as hexadecimal 4F in the EBCDIC data stream For more information about Variable ASCII lines receive mode see section 10 8 Disable Waiting for Processes to Complete before exiting You might want BARR RJE to exit automatically especially during unattended operation If a process is waiting to complete the software will not exit until the process f
553. sssssssssssssssssssss End of Page s sssss ssssss ssssss ss s PgUp Previous Page Scroll Page ti Find Text Disable Printer PgDn Next Page Go to Page Eject Page Print Test Page Start Print Block Print EBCDIC ASCII Escape The menu lists keys or options you can use to view or print files Viewing Options PgUp Previous Page Display the previous page PgDn Next Page Display the next page Scroll Page OHNO OY The left most columns of the current page display on the screen To see the complete page use the arrow scrolling keys The and keys scroll one screen at a time The keys scroll one line at a time The keys scroll 10 columns at a time Go to Page Move to a specific page number You are prompted to enter the number of the page you want to view New page 1 Enter number If the file contains no form feed characters you are prompted to enter the number of the line you want to view 426 24 7 Reprinting Files A specific page cannot be located The file has no form feed character defining pages New line Enter number Find Text Search for text You can enter a search string of up to 25 characters You can also search text beginning only in a specified column of each line or you can search entire lines Enter text to find Only search text starting in column _ 1 No Enter character EB
554. st BARR RJE interprets a pair of pound signs in a file as an embedded send files command If your files contain pound sign pairs that you do not want interpreted as send files commands include a backslash after the directory name followed by a 1 send mode for example read 1 See section 21 4 for more information about the embedded send files command Retain directory Optional The name of the directory including the drive letter where files will be moved after they are routed If no retain directory name is given the files are deleted after they are routed The retain directory must have the same drive letter as the read directory because the two directories must reside on the same logi cal drive or partition If a file with the same name already exists in the retain directory a unique numeric file name extension will be added to the new file so it does not overwrite the existing file See File Name Extensions in section 10 5 for more information n o 2 E a 3 G a a Fq oa Note Do not confuse the LAN connection retain directory with the print spool retain directory described in Chapter 9 Delete old Retain directory files If you use the retain directory feature choose whether old retain files will be automatically deleted Use this feature to periodically free disk space when you retain a large number of files No Default Retain files must be deleted manually If you retain a
555. st restart the PC for your changes to these files to take effect You can wait to restart the PC until after you install the Barr hardware Changes to CONFIG SYS In the CONFIG SYS file you might need to adjust parameters that affect file processing and memory management as described below S T sS pA w a 72 o FILES Parameter In the CONFIG SYS file set the DOS FILES parameter to at least 40 to enable the Barr software to access up to 40 files at a time The value required for FILES depends on the number of features you enable in the Barr software and the combined number of files those features must access simultaneously FILES 40 works in most cases If the Barr software needs to access more files than you allocate this message displays on the console during software operation DOS ERROR Too many open files use FILES 40 in file CONFIG SYS If you see this message set FILES 40 or increase the value by increments of 10 until the problem is resolved Memory Managers To achieve maximum performance at high communications speeds with SDLC or X 25 communication links do not use the expanded memory EMS feature of memory managers or use upper memory block UMB providers These programs might prevent you from achieving communi cation speeds of 256 kilobits Kb or greater However you can use extended memory with no adverse effect as described in section 18 6 Check your CONFIG SYS file t
556. stination devices you define in BARR RJE including the devices specified from the RJE Description Devices and Printers and Print Spool Description screens If you purchased any option software such as PRINT370 devices corresponding to those options also display From the Assign Devices screen you can direct the data received from source devices to the destination devices of your choice This action is called device assignment Default device assignments for software startup are defined in the Installation Description Each time the software starts the default assignments take effect You can change the assignments during software operation Your changes remain in effect until the software restarts This chapter explains data flow to and from the PC introduces you to the device assignment screen and describes the available source and destination devices Each section includes examples ECR Data Flow to and from the PC To understand the purpose of source devices destination devices and device assignment you need to understand how data flows into and out of the PC running BARR RJE This section discusses how data flows between the PC and the host computer and how data flows between the PC PC devices and the LAN You can receive data to the PC from the host computer the LAN or PC input devices such as a card reader You can send data from the PC to the host computer the LAN or PC output devices such as printers Data Flow bet
557. sure that the software makes the connection at the specified time EEZ AT Modem Options This section describes modem options for the AT modem selection and lists the command strings and command string sequences Modem Options gt To reach the Modem Options screen set Modify Options to Yes and press on the Modem Connection screen 208 12 4 AT Modem Options Modem Options Modem standard ITU T V 22 2400bps Connection Autodial Autoanswer on ring 1 Autodial retries 999 Starting time a CTS delay 150 ms Speaker On Reset to factory defaults Yes Choice Modem standard Select one of these options to match your modem standard ITU T V 22 2400bps ITU T V 22 1200bps Bell 212A 1200bps ITU T V 32 9600bps ITU T V 34 14400bps ITU T V 34 28800bps N 2 D 3 5 a 2 o 5 a Connection Specify the modem connection type The Connection Command Sequences section lists the command strings the software sends to the modem Autodial Default The modem dials the phone number and listens for a modem answerback tone Autoanswer The modem automatically answers an incoming call waits 2 seconds and sends the answerback tone for 3 seconds It then begins communication Manual You will manually dial the phone Autoanswer on ring The modem answers the phone after a specified number of rings Choices are from 1 to 9 The default selection is 1 ring
558. sured in seconds After the file is closed the data is sent to the destination device The default timeout period is 30 seconds Valid values range from 0 to 999 seconds You can use the timeout feature with the end of file marker to indicate the end of a file The timeout option is valid only if you set Close input file on timeout to Yes oo i D S o D an 9 Ss es mr Ss ae a Miscellaneous Printer Options for COM Devices You can use several printer options with COM devices to simplify print data processing or to solve printing problems gt From the Devices and Printers menu for the selected COM device select Miscellaneous printer options Miscellaneous Printer Options COM1 printer type Generic Printer performance optimized Yes includes expanding tabs not printing blank lines and generating VFU commands Conditional new page at end of file Yes Make all files have an even number of pages No Display count of lines or pages Lines Forms overlay directory Choice Printer performance optimized Choose whether to optimize printer performance by converting data as it is sent to the printer BARR RJE 71 n o 2 E a 3 G a a Fq oa Yes Default Printer performance is improved by changing the data as follows m Blank lines are converted to line feeds LF a If the printer has Direct Access Vertical Forms Uni
559. sy Date Time CHECKS CK501 1 0 1 1998 1 24 97 10 35 PRICES Hold LABELS 2 3 2 4840 1 24 97 10 44 TAX1040 1040 1 5 1 5180 1 24 97 10 35 INVOICES INV99 2 5 8 3262 1 24 97 10 36 Printers Sort t PgUp Help Files Check Spool PgDn Escape Restore The command menu lists the keys you can use to control print spooling This section briefly describes each command The rest of this chapter provides more information about each command Printers Change printer attributes Files Manage files You can change file attributes view files view a file s spool header and delete files If you see Ready Files instead the only file management task you can perform is to change the file state from hold to ready Sort Control the file display and print order Check Spool Update the print spool display after adding DOS or LAN files N A mi 3 N 3 o i 3 e S Restore Reprint a file from the retain directory Multipart Files If you receive a host file that contains PDIR job separators you might see several files on the Print Spool screen although you expect to see only one file If the host uses different PDIR information in different portions of a file it includes several PDIR job separators in the print file When you receive one of these files to the print spool BARR RJE divides the single host file into several files with PDIR records as file boundaries BARR RJE 411 This en
560. t DAVFU support the hardware skip to VFU channel commands are used to perform high speed skipping of blank lines DAVFU is a Dataproducts convention for specifying vertical forms control a Horizontal tab characters are converted to the required number of blanks to emulate tab settings at eight character intervals No Data is not changed when it is sent to the printer Conditional new page at end of file Choose whether the software should add a form feed FF to the end of a file if needed This option ensures that each file begins at the top of a new page which is helpful when form feeds are missing from some files Yes Default At the end of each file the software determines whether a form feed is included or whether the maximum page length is reached One of these conditions is necessary to ensure that the next file begins at the top of a new page If neither condition is met the software adds a form feed The software remembers if it adds a form feed and if the next file contains a form feed at the beginning the software removes it to prevent printing a blank page No Form feeds are not added to or removed from files Make all files have an even number of pages Choose whether all files should have an even number of pages for easier job separation No Default The number of printed pages can be even or odd Yes Ifa file has an odd number of pages add a blank page to make the number of pages even This ensures that the jo
561. t PU 19 Plotter 22 flow control on 65 Plotter output 194 196 EBCDIC data in 291 Portrait form 231 page mode 102 PORTRAIT overlay file 100 Portuguese character set 277 PostScript form overlay files 100 receive mode 182 Power 1Q40A message mount forms by 284 Power on reset 372 PR1 PR7 153 155 460 JES2 commands 242 Primary token ring adapter 299 Print compress output 230 extended ASCII codes 58 formatting output 102 odd even pages 226 options 290 Print lines per form PLPF 216 Edit Forms 219 FCB 520 spool header 509 Print output format 215 Print position maximum 291 Print queue 77 See also Novell print queues See also TCP IP LPR UNIX print queue translation table 87 Print queue name NetWare 116 Novell 79 88 TCP IP LPR UNIX 84 Print server 77 113 See also File server login as NetWare 78 114 564 Index maximum connections 78 114 NetWare name 116 NetWare password 116 TCP IP LPR UNIX address 84 Print speed timing delay affects 59 Print spool 321 operating after disconnect 302 retry state 90 session 349 404 See also Spool Print Spool Description 123 screen 123 124 Print Spool screen 124 126 commands 410 description 404 order of files 417 units 60 73 updating 420 Print stream 21 Print Test Page reprint command 131 428 PRINT TWINAX 32 devices 52 diagnostics 374 disabling spool header 191 PRINT370 12 31 439 devices 52 replaces Xerox 871CM 181 SETUPHDR with 517 spool
562. t 62 OUTPUT statement error 360 option 163 187 Overlay files See Form overlay files P Packaging BARR RJE 455 Packed decimal data send 342 Packet level statistics 386 X 25 386 Page break indicator 511 spool header 425 511 Pages even number of 57 72 formatting 102 print odd even 226 size 102 starting new 57 72 490 Pages printed display number of 60 73 log number of 356 Parallel port 12 21 158 501 Parallel printer 158 status 324 Parity bit 493 serial port 63 Partner Address 382 Password host display 310 NET device 89 NetWare queue server 116 Novell print queue 89 TCP IP UNIX queue server 116 PBX 206 PC files spooling 433 PC requirements 1 PC Service Access Point SAP See Service Access Point PC SYNC modem 203 204 264 connecting to BARR RJE 326 PC to PC file transfer 26 296 453 PC TCP kernel 82 PCL printer reset codes 106 PCTCP INI file 82 PDIR 516 copies 193 identifier byte 511 job separator 193 411 511 See also SETUPHDR values supplied by 516 Perforation skipping over 224 Perform loopback test 263 266 Performance tuning 802 2 connections 300 constant RTS 297 expanded memory 38 frequent disconnects 304 parallel ports 53 print spool 123 130 serial port input 63 serial ports 53 62 Peripheral Data Information Record See PDIR Peripheral device configuration 12 Phone See Telephone Phone numbers internal 206 long distance 205 modem connection option 205 PBX 206 Physical uni
563. t find it useful to save or retain a file after it prints in case you need to print another copy of it later You can choose to retain all files or selected files The retain directory must have the same drive letter for example C as the spool directory because the two directories must reside on the same logical drive or partition When you start BARR RJE for the first time it automatically creates this directory A file s disposition attribute controls whether it gets deleted or retained If you specify a retain directory all spool files are retained the file disposition is set to retain by default If you leave the retain directory field blank all spool files are deleted the file disposition is set to delete by default You can use the disposition field on the Print Spool screen or in the File Attribute Table to override the default disposition for individual files or groups of files Note If you leave the retain directory field blank but you tell the software to retain a file the file will be saved to the root directory usually C of the drive where the spool directory resides Also you will not be able use the Restore feature If you specify a retain directory you can use a separate Restore screen to manage the files stored in the retain directory The Print Spool and Restore screens are described in Chapter 24 Print Spool Operation The File Attribute Table is described in section 9 5 See section 9 4 for more reta
564. t if there are differences in both the FCB and FORMS specifications ucs The output group s universal character set must match the device s universal character set UCS Examples T PR2 K 1 single spaces printer 1 to the end of the dataset a T PR2 F 2031 sets printer 2 to form 2031 T PR1 F STD sets printer 1 to the standard form T PR2 Q ACDUS sets printer 2 to classes A C D J and S gt J 3 2 o o 3 3 D 2 z T PR2 F STD Q AC sets printer 2 to the standard form and print classes A and C T PR1 S N deletes header and trailer pages from each job on printer 1 T PR2 S Y causes header and trailer pages to print for each job on printer 2 BARR RJE 479 T PR1 X N suppresses JES2 translation of lowercase characters and control characters T PR2 S Y causes header and trailer pages to print for each job on printer 2 T PR1 WS F removes forms from printer 1 s work selection which means all forms can print T PR1 WS F adds forms to printer 1 s work selection and the form on the output group and output device must match before the slash T PR1 WS F adds forms to printer 1 s work selection after the slash Z Halt The Z command immediately stops a printer or punch After the device stops the operator can restart it one of these ways The E command starts reprinting or repunching the job from the beginning The command causes
565. t of receive modes the following options display at the bottom of the screen Assign Devices SEND1 RD1 SEND2 SCREEN KEYBOARD gt COMMAND ON SCREEN LOG NUL PR1 SPOOL PU1 SUSPEND SPOOL1 LPT1 Block size 80 Carriage control none Logical record length 80 Character set EBCDIC DCB RECFM FB BLKSIZE 80 LRECL 80 Enter number 1 Select values for the fields Use the arrow keys to move around the screen 2 Press to preserve your changes Then press to return to the Assign Devices screen Note The last line on the screen DCB contains the IBM JCL Data Control Block DCB description This line changes to reflect your selections Fixed Length Options Specify these Fixed length options Block size The maximum length of blocks written to tape The block size is ignored unless the destination is TAPE The maximum value is 32760 BARR RJE 183 Logical record length The total length of the fixed length records including the ASA carriage control character if any The maximum value is 255 If you select ASCII variable or EBCDIC variable for Character set records will have a variable length To prevent the variable length records from being truncated set the logical record length to the maximum value Carriage control The type of carriage control none Carriage control characters are discarded 4 2 gt 7 i K ASA ASA carriage control is used BARR RJE conv
566. tain directory 110 NET device 82 PRT 436 438 File format 342 reader 292 See Receive mode File header See Spool header File name beginning of 162 168 combine beginning and ending 163 DOS conventions for 162 duplicate 164 167 ending of 163 164 167 170 errors 162 172 359 extensions 167 from file 164 170 job name as 163 167 OUTPUT statement 187 188 BARR RJE 557 screen 161 167 170 174 source file 164 spool 436 terminate 171 FILE screen See File name screen File separator 439 511 File server 77 113 connections 78 90 114 File server name Novell NetWare queue 116 Novell print queue 79 88 File transfer 333 338 advanced 31 BARR TRAN 31 dial up connection 453 features 24 26 JES2 network 454 mainframe to PC 30 PC to mainframe 30 PC to PC 26 31 453 tape support 30 Files append to 165 committing to disk 309 concatenating several 341 creation date and time 284 deleting 417 divide at PDIR 193 group output 164 168 ignore lines at start of 189 192 include spool header 191 log option 166 open new 165 166 print 119 print attributes 413 received with wrong form 408 receiving output to 161 replace conditional 165 166 replace existing 165 166 reprinting 423 RJE printer 155 route to host 154 See also Routing files See also Sending files spool directory 403 too many open 358 transfer 338 viewing 414 Files command 130 411 413 FILES 40 DOS parameter 38 message 358 Find Text reprint
567. taproducts Interface 6D 01 LPI 8 m STX 02 VFU Support for 6D LPF nn 6E 41 40 r 6F BARR DPI adapter r nn 1 repetitions of 40 40 nn 1 to 143 all codes sent with Paper Instruction high EPSON IBM LPI 6 ESC 2 in serial matrix mode 1B 32 LPI 8 ESC 0 1B 30 LPF nn ESC C nn 1B 43 nn nn 1 to 127 as binary byte 96 8 6 Choose Printer Type Table 8 1 Printer Control Codes continued Printer Model Setting Control Codes Florida Data LPI 6 ESC RS BS 120 130 1B 1E 08 LPI 8 ESC RS ACK 1B 1E 06 LPF nn ESC FF nn 1B 0C nn nn 1 to 126 as binary byte Genicom LPI 6 ESC 1 2 0 SPG 4410 4440 1B 5B 31 32 30 3B 20 47 LPI 8 Esc 9 0 SPG 1B 5B 39 30 3B 20 47 LPF nn ESC x r 1B 5B x 72 x nn 720 LPI as ASCII digits nn 1 to 132 Genicom 1255 Linewriter LPI 6 Esc 1 z parallel 1B 5B 31 7A LPI 8 ESC 2 z 1B 5B 32 7A VEU Support LPF nn 1D 41 40 r 1E r nn 1 repetitions of 40 40 nn 1 to 180 Hewlett Packard 256x LPI 6 ESC amp 1 6 D 1B 26 6C 36 44 LPI 8 ESC amp 1 8 D 1B 26 6C 38 44 LPF nn ESC amp 1 m P 1B 26 6C nn 50 nn 1 to 128 as ASCII digits Linewriter 400 800 LPI 6 1 2 0 SPG RS232 serial 9B 31 32 30 20 47 LPI 8 9 0 SPG 9B 39 30 20 47 NCR 6430 Fujitsu M304x LPF nn T nn 2 2 L1 1 2 RS232 serial 90 23 54 nn 9C 90 23 4C 31 3B 31 9C nn 1 to 180 as ASCII digits OKIDATA 92 93 LPI 6 ESC 6 1B 36 LPI 8 ESC 8 1
568. tem provides a set of services to all programs for input output data manage ment program loading memory alloca tion and communication facilities for job entry and output dispatching operator commands Commands sent to the host computer Os See operating system Auesso 9 output Data produced by a computer program BARR RJE 543 Glossary pacing In SNA communications a method to control the flow of data from VTAM to the remote parallel interface port A device interface to the computer that reads and writes groups of bits at the same time A common way to connect printers to the PC parameter A variable that is given a constant value for a specified application parity A bit appended to a group of binary digits to ensure that the sum of bits is either even or odd Serves as an error detection scheme for data communications PC Personal computer or microcomputer PCM Pulse Code Modulation code A coding scheme used for digital transmission of telephone calls The analog telephone signal is sampled 8 000 times a second For each sample an eight bit code is constructed This digital code is sent within the telephone system The eight bit code is converted back to the analog signal prior to being put on the local telephone line PC TCP FTP Software Inc s kernel that interfaces between Barr software and the TCP IP network peripheral devices Equipment attached to the computer that
569. tended memory buffers available Only nnnn Kbytes of extended memory is available for use If you allocate too many extended memory buffers meaning the overhead required for the extended memory buffers exhausts the amount of conventional memory this message displays XMS Buffers Not Allocated Not Enough Real Memory See section 18 6 Trace and Memory Options for information about adjusting the memory options SHARE EXE Not Loaded If you enable the print spool feature as described in Chapter 9 you might see this message when you start the software WARNING SHARE EXE has not been run Spool may not function properly You must load the DOS SHARE EXE file sharing utility if you use your PC local drive for example C for the print spool directory Add the line C DOS SHARE to your AUTOEXEC BAT file as described in section 6 2 When SHARE EXE is not loaded you might see print problems such as overprinting for files printed by the print spool See your DOS manual for more information about this utility i o a i Wu c gt s c co rr N Too Many Files Open If the Barr software needs to access more files than you allocated this message will display on the console during software operation DOS ERROR Too many open files use FILES 40 in file CONFIG SYS If you see this message edit the CONFIG SYS file and set FILES 40 or increase the value by increments of 10 until the problem is res
570. teps for a manual dial connection 1 With both modems set to Talk the PC 1 operator calls the modem number of PC 2 2 The PC 2 operator answers the telephone 3 Both operators change modem settings from Talk to Normal and hang up the telephones BARR RJE 453 When the PCs connect the word BARR appears in large letters on both PCs The operators can still communicate from the console Send Files Both operators can send files independently from the Operation screen Follow file names with the TB send mode to send files in Transfer Binary format 1 Select Send Files to RD1 2 Type filename TB File Transfer through the JES2 Network A JES2 communications network can transfer files between PCs with BARR RJE The sender of the file must specify the remote name of the receiver The sending and receiving BARR RJE program configurations must be identical Configure BARR RJE for JES2 Network Transfer To configure BARR RJE for a JES2 network transfer follow these steps from the BARR RJE Operation screen Select Advanced Select Assign Devices Select PU1 as the source device Select FILE as the destination to assign PU1 to disk Type the name of the directory followed by a backslash a i S 2 Z lt 5 o o Z pej N Select Receive mode Select Transfer files CNY DHA BF wWN Press twice to return to the Operation screen File Transfer Example Th
571. teps to enable the FCBLOAD feature 1 Enable FCBLOAD at the host computer 2 Enable HASP190 at the host computer 3 Set Use Barr FCBLOAD and Mount forms by options in the Barr software 1 Enable FCBLOAD parameters at the host computer FCBLOAD is enabled with the PSERVIC and FCBLOAD parameters a PSERVIC Parameter PSERVIC the LU presentation services profile is defined in the VTAM Logon Mode Table Entry or LOGMODE Chapter 1 of the Barr Host Definition Guide discusses the Logon Mode Table Entry and corresponding PSERVIC parameter for your operating system a JES2 FCBLOAD Parameter To enable the FCBLOAD feature for MVS JES2 the host programmer must enable both the PSERVIC parameter in the LOGMODE as discussed above and the FCBLOAD parameter in the Remote Definition For JES2 XA or JES2 ESA specify FCBLOAD on the Remote Printer statement RMTnnnn PRn Chapter 1 of the Barr Host Definition Guide discusses the JES2 Remote Definition a JES3 LDENS Parameter For JES3 in addition to enabling FCBLOAD in the PSERVIC parameter you also must enable the LDENS parameter to receive Set Vertical Format On the Device Definition statement DEVICE for the selected remote printer set LDENS YES Chapter 1 of the Barr Host Definition Guide discusses this parameter 2 Enable the JES2 HASP190 message at the host computer You enable the JES2 HASP190 message with a parameter in the RJE Remote Definition For JES2 XA speci
572. ter m Into the PC BARR RJE 265 z N 5 amp c a 5 paa S a Test Steps Start at the Interrupt Request Address and Loopback Test screen Interrupt Request Address and Loopback Test Interrupt request IRQ2 Address 280 DMA request 1 Perform loopback test Yes Choice 1 Select Yes for Perform loopback test The screen lists the installed adapter and shows the IRQ address and DMA settings assigned Interrupt Request Address and Loopback Test The SYNC adapter is installed it will use IRQ2 address 280 and DMA level 1 For SYNC adapter set jumper for address 280 Any key 2 Press again to advance to the first screen of the loopback test Follow the instructions on the screen for each phase of the test The software updates information on the screen during each test phase and then displays the test phase results The following screen displays for Phase 1 266 17 2 Perform Loopback Test Loopback Test of SYNC Adapter This is a comprehensive test of the synchronous communication adapter cable and modem The test consists of three phases The first phase makes sure that the adapter is installed correctly and that all settings are correct Press any key to begin the test Any key 3 Press any key to start the test The software performs the Basic Recognition T
573. ter Forms for instructions to define forms Spool Copies If you plan to print multiple copies use SETUPHDR to get the number of copies from the host and use the Barr print spool feature for printing the copies The print spool is a more cost effective and efficient way to print several copies of the same file If you do not use the print spool the host computer must send the file over the communications line multiple times With the print spool feature the host computer sends the file to the PC once and the print spool sends the file to the printer the specified number of times Specify COPIES n on the JCL DD or JCL OUTPUT statement for the job This parameter causes the host to send a copy count to the remote in the SETUPHDR PDIR record EX Using FCBLOAD with HASP190 Using FCBLOAD with the HASP190 message allows you to obtain all form information from the host Use this method if the forms at the host are too numerous to define in the Barr software and if FCBs are compatible with remote printing The host stores each set of print format information as a Forms Control Buffer FCB When FCBLOAD is enabled the host sends an FCB to the remote PC with each print file FCBs are stored in a library at the host computer and are usually maintained by a systems programmer If your site is converting from host attached printing to remote printing host forms probably are already defined FCBs do not contain the form name or FCB name
574. ter opened but transmit buffers too small for MAXDATA of 1033 E43 SAP already in use E46 Resources unavailable BARR RJE 369 22 Comm Scope Table 22 4 802 2 Scope Characters continued Characters Description Notes Frmr Frame reject Indicates incompatible frame size between partners Check that MAXDATA set in BARR RJE matches MAXDATA set for the mainframe or controller if attached to a 3174 Controller See Chapter 2 of the Host Definition Guide for more informa tion about MAXDATA I Initialize Initialize the token ring adapter Performed only if not already initialized L Open link Allocate a link station before making a station connection when in host mode Pc Computer error Indicates hardware error Ring Ring error Adapter has detected a token ring error Rnr Receive not Local station or remote partner has entered ready a local busy state which is caused by a low buffer condition Rr Receive ready Local busy state has cleared S Open SAP Allocating and opening a Service Access Point Sabme Set Request for connection was received from Asynchronous the host Balanced Mode Extended Stat Status request E09 and E0C are valid normal responses Other status might indicate adapter errors T Timeout No response from the host adapter Undf Undefined An unrecognized frame was received Should never occur Xid Exchange After the remote sends Xid to
575. ternational Business Machines Personal Computer IDBLK IDNUM In SNA communications identification data used for dial up devices See also Xid input Information that is read into a computer Messoj9 Installation Description Installation program for entering BARR RJE configuration options BARR RJE 539 interface The connection between any two hardware or software components in a system interrupt Mechanism used to stop a program for an event needing immediate attention 0 Input Output Represents data transfer between a computer and peripheral equipment IPX See Novell IPX IRQ Interrupt request A request for processing on a particular priority level ISA Industry Standard Architecture a standard for the PC s expansion bus where you plug in add on adapters The IBM AT bus became a 16 bit ISA bus JCL Job Control Language A language interpreted by the operating system JES2 and JES3 Job entry subsystems of the IBM MVS operating system These subsystems are used for entering jobs into the MVS operating system and dispensing the output from the jobs JES2 and JES3 are replacements for the HASP II program that was used for this same purpose job An independent unit of work that is pro cessed by the host operating system A job consists of JCL statements program ming language statements and data to be processed The output of a job includes printed output and updates to files on dis
576. tes the last page printed and repositions to the top of that page This method BARR RJE 131 works best for reprinting huge files for example files that contain 100 million bytes It requires processing to track pages as they print Retain Options These advanced spool options control the spool retain feature for saving and restoring spool files Display spool header information on Retain directory screen Choose whether to automatically display file attributes for all files on the Restore screen Your selection affects how quickly the Restore screen displays and depends on the average number of files stored in the retain directory at the same time i o N o a i A a oa Yes Default File attributes from the spool header display on the Restore screen when you select the Restore command Use this selection if on average less than 300 files reside in the retain directory When you select the Restore command on the Print Spool screen the software processes each file s spool header and then displays the Restore screen When the retain directory contains hundreds of files spool header processing can take several minutes and delay display of the Restore screen For example if 2 000 files are in the retain directory it could take 10 minutes for the Restore screen to display No With this selection file attributes do not display for every file but you can display attributes for select
577. the length of the delay depends on your PC s processor speed The amount of the delay required also depends on your line printer The default value of 8 applies to PC AT workstations and most line printers For a BARR DPI printer adapter set the timing delay value to 0 The BARR DPI adapter supports printers with the Dataprod ucts interface The maximum value is 9999 cycles If you need to change the timing delay adjust it on a trial and error basis First set the timing delay to a large value such as 300 and note how the new value affects the printer If the value is too high the print speed will be noticeably slower If the value is too low the original problem will still be evident Adjust the value up or down in smaller increments until the problem is resolved and the print speed seems normal co i D S o D i 9 Ss es me Ss o a For a description of the busy line see the JBM Technical Reference Options and Adapters Volume 1 Graphics Printer section Over driving the printer is impossible if you use the IBM definition Unfortunately not all printers use this definition Barr Systems Technical Support can help you tune this option Audible alarm on printer error Choose whether the PC will make a shrill beep when an error or paper condition occurs The noise will stop when you correct the condition or press a key on the keyboard No Default Disable the error alarm Yes Enable the error alarm
578. the code Guidelines for Making Table Entries The Printer Control Data screen has 10 entry lines that can hold up to 20 control characters each If you need to enter more printer control codes than you can fit on this screen you can create files containing these codes instead Use a program editor that supports entry of hexadecimal codes to create the files then use the forms overlay feature to send the codes to the printer See section 8 7 for a detailed description of the forms overlay method co i o S o an 9 Ss es me Ss a a Follow these guidelines for entering control codes a Use the keys to move around the screen If you make an error you can use the key to return the screen to its original values When you press Enter the new values are stored The key will not clear stored values You can type over any stored values you want to replace You can link printer control data to Barr printer forms that you create with the Edit Forms option See sections 13 2 and 13 3 Special Control Characters In the Printer Control Data table different types of control strings are distinguished by special control characters Applications for the various control strings are described below String separator Each control string must be terminated by two pairs of hexadecimal zeros 00 00 Strings do not have to start on a new line A string that begins on one line can wrap to the next line
579. the data and the trailer page In some instances the host computer combines multiple outputs into one file and includes a PDIR record before each set of output _ A 2 5 D S o 7 Note If you receive files to the print spool and the PDIR copies value changes within the file the file will be divided into separate files to allow the print spool to handle the different copy counts This is an automatic feature of the print spool that is not affected by the Create separator files option No Default Files with multiple PDIR records are not divided Yes A new file is created each time a PDIR record or PDIR job separator is encountered in a received file whether or not the PDIR information changes Separate files are created for the banner page trailer page and data More than one data file will be created if PDIR records occur several times within the data IMAI Assigning Several Sources to One Destination The BARR RJE software allows destination devices such as printers to be shared which means several source devices can write to the same destination device Destinations often shared include LPT1 to LPT3 COM1 to COM4 and RD1 to RD4 When you assign several sources to the same destination the software alternates between source devices which allows each source to write to the destination in turn For example if the source PR1 is ready to write a file to the destination LPT1 the software first check
580. the file name field will be blank If you choose fcbname formname or jobname the corres ponding name from the spool header or host data stream will print in the banner s file name field RJE 3270 If you have RJE 3270 software note that the job name is not included in 3270 data streams and thus cannot be included on the print banner 80 8 5 NETI NET12 Devices Use Novell form numbers This option allows you to control Novell form number processing for NET devices The Novell PRINTDEF utility is used to define forms on the network print queues No Default Novell form numbers are not used Yes The mainframe form number stored in the Barr spool header is passed to the Novell Print Queue so that a Novell form can be used when the file is printed If the form name in the spool header is not numeric the Novell form number is set to zero oo i oO S o o a 2 Ss s m Ss a a Add form feed between jobs This option is useful when you send jobs to laser printers It ensures that the last page of the job is flushed from the printer before the next job starts Yes Default Form feeds are added between print jobs No Form feeds are not added Device Driver If you select Device driver as the NET device network type the following field displays on the lower half of the screen Network Printer Options NET1 network type Device driver printer type Generic Device name Enter characte
581. the host through a dial up line dedicated line or LAN Dial Up Line With a dial up switched line you connect through modems by dialing the mainframe s telephone number Ask your host communications consultant which modem types the mainframe supports and the telephone BARR RJE 13 2 RJE Concepts number to use with your modem The Barr adapters used with modems support speeds up to 384 000 bits per second bps The actual speed achieved on your communication line depends on the speed supported by your data communication equipment Dedicated Line With a dedicated line non switched leased the host computer and remote workstation connect directly No dial up procedure is required The communication lines can be privately owned or furnished by a telephone company You can achieve faster communication speeds on a dedicated line than on a dial up line The actual speed achieved on your communication line depends on the speed supported by your data communication equipment BARR RJE supports dedicated line speeds up to T1 1 536 000 bps and E1 2 048 000 bps 802 2 Network The mainframe connects to the 802 2 network to communicate with IBM 3174 3725 and 3745 communications controllers The PC workstation uses a token ring or Ethernet adapter to connect to the network LAN Gateway RJE workstations can connect to the host computer through the BARR GATEWAY which maintains the physical connection to the host You can conn
582. the index 01 Finally the software sends the file to the printer ak oo im 5 Q n 3 a Example 2 Landscape and Portrait Orientation A laser printer is capable of printing pages with portrait 8 5 x 11 and landscape 11 x 8 5 page orientation You can set the desired mode on the printer with printer commands This example shows how to define a form named PORTRAIT to print in portrait page orientation and a form named LAND to print in landscape format On the HP LaserJet the hexadecimal landscape mode codes are 1B 26 6C 31 4F and the portrait mode codes are 1B 26 6C 30 4F The following steps describe how to define these two sample forms 1 Create the landscape and portrait forms Create forms named LAND and PORTRAIT as follows Edit Forms Name LAND Lines per form 51 Print lines per form 51 Lines per inch 6 Printer control 01 Enter character a For the LAND form enter 01 as the Printer control index BARR RJE 231 Edit Forms Name PORTRAIT Lines per form 66 Print lines per form 66 Lines per inch 6 Printer control 02 Enter character b For the PORTRAIT form enter 02 as the Printer control index 2 Enter command sequences for landscape and portrait modes Next you need to enter the printer control data for the selected LPT COM or NET device a Skip the first two pairs of zeros 00 00 at the beginning of the t
583. the job to resume where the operator stops it The operator can use Z to check items like form alignment and paper feed without affecting the printed output Format CA D c lt x Enter the Z command as follows Z dev where dev is the device to stop Example Z PR2 stops printer 2 immediately 480 A 1 JES2 Remote Commands EFJ JES3 Remote Commands JES3 operator commands allow remote terminal operators to communicate with the JES3 system This section lists the most used JES3 remote commands See the IBM JES3 Commands manual SC23 0045 for more information about JES3 commands JES3 Commands Command Controls or Displays F modify job system parameter resource I inquiry job device queue message R restart job device line S start job device ABEND or DSP X call DSP Each command is described in a separate subsection JES3 Command Format Enter JES3 commands from a console as follows command operand1 operand2 where is the JES3 command identifier Check with your host programmer about when to use the JES3 command identifier command is a single word or single character verb that identifies the action to take Do not insert blanks between the and the command You can enter the command in uppercase or lowercase letters operand modifies the command Use a comma or single blank space to separate operands Use apostrophes when they appear with
584. the operation of a computer including a keyboard and display or printers control codes Any character used to facilitate transmis sion of data between the PC and the host control unit See communication control unit CPU Central processing unit The part of a computer system that controls the inter pretation and execution of instructions input and output units and auxiliary attachments It consists of a control unit and an arithmetic logic unit ALU CRC Cyclical redundancy check A form of error correction that catches all one two and three bit errors in a sequence current directory The directory where you start BARR RJE or the directory you change to when you hot key to DOS after BARR RJE starts data A representation of facts concepts or instructions in a formalized manner suitable for communication interpretation or processing by human or automatic means data control block DCB A control block used by access method routines to store and retrieve data Data Link Control Protocol Communication rules for the orderly exchange of information between two 536 Glossary nodes on a data link The lowest level protocol of SNA and BSC Dataproducts Interface DPI An interface that originated with the Data products Corporation used for driving high speed printers and typesetting equip ment DAVFU Direct Access Vertical Forms Unit A control sequence of characters used to define a vertical
585. the transfer completes normally you can instruct DOS to delete the PC file as in the following example BARRSNAR FILE DAT IF NOT ERRORLEVEL 15 ERASE FILE DAT 456 26 3 Packaging BARR RJE in an Application EX Assuming the Host Communication Role BARR RJE can assume either the remote or the host communication role Set BARR RJE s communication role from the Tuning and Global Options Modem and Line Control screen If you set the communication role to host mode commands you enter on your keyboard appear on the remote s screen When BARR RJE operates as the host it communicates with any SNA remote including these older remote systems Harris Corporation s Harris 1610 Datapoint Corporation s Datapoint 1800 IBM Corporation s IBM 3777 3 When to Use Host Mode You can use host mode to copy punch decks to files on the PC You can also use an older SNA workstation with a card reader to send the punch decks to the PC running BARR RJE by assigning PR1 FILE Files sent from either the host or remote appear on PR1 of the receiving system Any form feed characters for new pages are converted to the skip to channel 1 character The following example illustrates the correspondence between the host and Y remote devices 2 wo BARR RJE 2 as Host Remote gzl Files sent RDI PRI to remote RD2 ___ __ PR2 gt 77 RD3 __ PR3 RD4 _ PU1 COMMAND CON Files received P
586. time intervals Host The host sets time intervals remotely LTTI Last Transaction Time Indicator Displays the last transaction response time Table of Response Times amp Counters The counters indicate how many transaction times fell in the response time ranges These ranges display in seconds and are set either by the local operator or the host operator The last counter represents transactions that exceeded the largest range Operator Generated Alerts Screen 1 To access the Operator Generated Alerts screen start at the NetView screen NetView Response Time Monitor Operator Alerts Escape Selection l gt 2 Select Operator Alerts BARR RJE 397 N oo o Ej 3 D K Ss an o na an o S a D S a E E oO m N Operator Generated Alerts Operator generated Alert Screen 1 Message Q1 02 Q3 Enter number Operator generated Alert Screen There are 20 Operator generated Alert screens Each screen repre sents a user action code that correlates with up to 20 product unique panels which you can define in the NPDA database as part of the system generation process Message Optional 120 character text message Q1 8 character optional qualifier Q2 8 character optional qualifier Q3 8 character optional qualifier After NetView receives the alert message it uses the user action code or screen number to
587. tion Assign Devices SEND1 RD1 SEND2 gt SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PR2 LPT2 PU1 SUSPEND SPOOL1 LPT1 Continue Escape Receive mode Options Help 3 Select Continue to make another assignment or press to return to the Installation Description menu You also might want to assign a receive mode or options See sections 10 8 and 10 9 for more information about these features 160 10 4 Assigning a Printer as a Destination EUW Assigning a File as a Destination You can direct data to a DOS file on a disk or the LAN Typically you direct data that will not be printed to a disk file so it can be processed by programs on the PC or the LAN For example you can direct data received from RJE punch 1 PU1 to a file by assigning PU1 FILE When you assign a file destination the software prompts you to enter a file name and you can select other options Follow these steps to assign FILE as a destination Assign Devices _ A 2 2 5 i S o D 7 SEND1 RD1 SEND2 SCREEN KEYBOARD COMMAND CON SCREEN LOG NUL PR1 SPOOL PU1 SUSPEND SPOOL1 LPT1 Select SOURCE DESTINATION Escape Selection tlo 1 Select the source for example PU1 and press Enter A list of destina tions displays Assign Devices DESTINATION FILE SCREEN NUL SUSPEND LPT1 COMMAND RD1 SPOOL Selection tJ7 2 Select FILE as the
588. tion Command to Host Send Files to RD2 Advanced Quit Send Files to PROE Mount Forms Selectiont gt Use the first Send Files command to send files to RD2 m Use the second Send Files command to send files to PROE Steps for Sending Files Follow these steps to send a file from your PC to another device 1 Assign the SEND1 or SEND2 device to the desired destination on the Assign Devices screen CENTRAL HOST NAME COMMUNICATION SCOPE 0 0 LPT1 0 busy LPT2 0 normal 16 48 14 N _ io gt J J ps J pas m 3 o 5 Operation Command to Host Send Files to RD2 Advanced Quit Send Files to PROE Mount Forms Selectiont gt 2 Select the Send Files command with the desired destination For example select Send Files to RD2 to send files to the mainframe BARR RJE 339 i o a i Wu c gt s c co rr N Enter file names To combine files separate by a plus To start a new file leave a blank To cancel press Esc Files 3 Type the name of the file to transfer Send Files Guidelines Follow these guidelines when you specify file names a When you send multiple individual files use a space to separate the file names a When you send multiple files as a single concatenated file use a plus sign to separate the file names When you specify file names you c
589. tion the Serial Port Options screen displays See Serial Port Options later in this section for more information about this screen Miscellaneous printer options Several options affect printer performance For a description of these options see Miscellaneous Printer Options for COM Devices later in this section For a description of other options that affect printing see section 18 2 Tuning and Global Options Printer Control Printer control data Printer control data is used to send control codes to the printer such as commands to set the lines per form and lines per inch or commands to reset the printer You can use printer control data alone or with Barr printer forms Section 8 8 tells you how to set up this feature Escape This option appears twice on the screen Select Escape or press the key to return to the Devices and Printers menu 62 8 4 COM1 COM4 Devices Serial Port Options The serial port and serial device settings must match gt Select Serial port options from the COM device screen Serial Port Options COM3 printer type Generic Baud rate 4800 Parity None Data bits 8 Stop bits 1 Hardware flow control CTS XON XOFF flow control No Interrupt request IRQ4 oo i o S o o an 2 Ss s me Ss a a Use this device as a data Source as well as Destination No Choice Baud rate 4800 9600 19 2K 38 4K 57 6K 115K 110 150 300 60
590. tion about the INSTALL EXE program You can view this file with the DOS type command or a file editor INSTALL EXE The program to expand and copy the files from the disk to the PC CONTROL DAT A text control file used by INSTALL EXE These Barr program and reference files will be loaded onto your PC PRODUCT EXE Barr software files compressed into one file REF EXE Barr reference files compressed into one file REF370 EXE Reference files provided with the PRINT370 option compressed into one file BARR RJE 39 TRAN EXE Files for optional enhanced file transfer capabilities compressed into one file BARR TRAN reads or writes all MVS mainframe files defined by the JCL Data Control Block specification DCB RECFMS r LRECL n BLKSIZE b It supports popular record formats including fixed length FBA and variable length VB formats nnnn ADF Adapter description files used for installing Barr Micro Channel adapters in PCs with a Micro Channel bus These files are not compressed S S T S B S 7 o If you purchased other software options additional files might be included on your disk The corresponding Barr software option manuals describe any files not listed above Software Installation Steps The automated installation process is easy to use and is the most convenient way to load the software files onto your PC The installation process allows you to install new software or a s
591. tions Printer Control screen Using Electronic Forms Electronic forms are a replacement for preprinted forms The forms overlay feature of many laser printers allows an electronic form to be printed automatically with every page of a data file You can then use plain paper instead of preprinted forms paper For example the software sends the text of an invoice form to the printer only once and the printer loads it as an overlay Next the software sends the data file and each page of data is overlaid with the invoice form so that both the form and the data print on the page To create electronic forms you need a form design package Use the software to create forms and insert special printer codes You must store the completed forms as overlay files in the BARR RJE forms overlay BARR RJE 99 directory When the Barr software is ready to print a file it checks the forms overlay directory and sends the corresponding form overlay file to the printer before it sends the print file For more information about form design packages and form management request the Electronic Forms Management booklet from Barr Systems Loading Printer Control Data or Printer Resources You can use the forms overlay feature to send printer control codes to the printer as an alternative to using the Printer Control Data screen in the Barr software The forms overlay method is especially useful if you need to enter more printer control codes than you can fit
592. tions 297 Security features 310 Selecting screen options 33 Selection prompt 34 SEND Device screen 106 Send Files at startup 346 from LAN 347 function keys 347 messages 354 Send Files command 68 69 154 338 cancel 344 embedded 100 110 252 253 344 347 test printer 503 Send Files option 252 Send mode 176 342 1 110 LAN connections 109 SEND1 SEND2 53 153 154 disable 107 enable 107 log activity on 354 Sending files concatenated 340 format 342 multiple 340 BARR RJE 567 Sending files to host 106 154 from LAN connections 112 from serial port 66 68 105 Serial number adapter iv Serial Numbers screen 401 Serial port 13 21 66 154 158 452 502 as source device 65 busy 70 close input file on 71 COM1 COM4 497 configuring 502 data conversion 451 flow control 64 IRQ 65 options 63 printer cable specifications 498 protocol conversion 451 release 70 speed 63 Serial port input 154 backslash 66 68 cancel job 70 enable 66 error message 67 errors 361 host command 66 68 sample applications 66 Serial Port Input Header 66 104 example 105 Serial Port Options screen 63 Serial port signals 25 pin 497 9 pin 498 Serial Port Source Options 66 screen 68 Serial printer 158 status 325 Server See File server See Print server Service Access Point SAP 299 statistics 381 Sessions initial 312 screen 348 switching 349 350 Set device command JES2 477 Set Line Density SLD values supp
593. tions lines you must select No The Request to Send signal is always on even when the software is not sending data To function some full duplex modems require that this option is set to Yes ob oo im gz i gt an Performance Tuning For high speed lines setting Constant RTS to Yes can dramatically improve performance because it eliminates the RTS to CTS delay Ignore DSR 0 Select whether the BARR RJE software should ignore the modem Data Set Ready DSR signal when DSR 0 You can use this option to diagnose communications problems No Yes Default Begin communication only if the DSR line is a 1 DSR 1 Communication will not begin if DSR 0 For SDLC links the text DSR 0 displays on the Operation screen s Status Line until the connection is made Ignore the DSR line Communication can begin if DSR 1 or DSR 0 With this selection the text DSR 0 does not display on the Operation screen s Status Line You can use this option to diagnose communications problems DSR 0 could indicate a problem with the communications interface communications cable or the device generating the DSR signal BARR RJE 297 Drop DTR on exit Specify whether or not the Data Terminal Ready DTR signal will be lowered or dropped when the software exits Yes Default The DTR signal is dropped after the software exits which causes the modem to hang up the telephone No When DTR is not dropped th
594. tions properly by performing diagnostics on the synchronous adapter cable and modem Test Phases The loopback test consists of three phases a Phase 1 Adapter installation and settings a Phase 2 All adapter functions a Phase 3 Cable and external modem Because an internal modem has no modem cable or test plug phases 2 and 3 do not apply to PC SYNC internal modems 264 17 2 Perform Loopback Test Phase 1 Adapter Installation and Settings You can run Phase 1 without the test plug or a modem connection This phase verifies that you installed the adapter correctly and that all settings are correct Phase 2 All Adapter Functions Phase 2 requires the test plug that comes strapped to the modem cable Insert the test plug into the adapter This phase reports adapter problems Phase 3 Cable and External Modem Phase 3 requires you to set your modem to analog loopback AL mode Data does not enter the telephone in this mode it loops back from the transmit to the receive side of the modem In this phase the PC sends data in this order Through the send side of the Barr adapter m Into the cable _ N 53 o 3 J o 2 an From the cable to the modem Through the send side of the modem The data returns in this order Through the receive side of the modem From the modem to the cable From the cable into the Barr adapter Through the receive side of the Barr adap
595. to enable the FAT You can use a table of file attributes to automatically set attribute values for print spool files or override existing attribute values You can maintain the table internally from the Installation Description or externally from a separate file No Default Do not use the FAT Yes Use the FAT to set or override file attributes as files arrive in the spool directory The applied changes are written to the spool files where they are stored in the spool header Use the next three options to specify additional FAT features Match FAT entries using Choose which two fields to use as the file match criteria This option controls how the FAT displays and works and applies to either an internal or external FAT Match criteria are used to determine whether or not FAT entries will be applied to a file For more information about file match criteria and file override values see How the Table Works later in this section Filename Formname Default File name and form name are used as the match criteria Entries in the FAT are applied to spool files when the file name and form name of a file match a table entry With this selection the column headers of the File Attribute Table screen for an internal FAT appear as follows BARR RJE 135 i o N o a i A a oa Filename Form State Class Prty Copies Disposition The State through Disposition fields are used as ove
596. to exceed the original value for conventional buffers the value before extended memory buffers were added and conventional memory buffers were decreased Keep the amount of extended memory buffers within 50 to 100 KB of the original amount of conventional memory For example if you were using 200 000 bytes of conventional memory try setting the amount for extended memory buffers to 100 to 150 KB and the value for conventional memory buffers to 100 000 bytes ob oo im kzi i gt an Do not set the amount of Extended memory allocated for buffers to values of 500 KB or greater even if that much extended memory is available unless you use Oc model 2 printers See the PRINT370 manual for more information This would be an excessive amount and could use from 100 to 300 conventional memory buffers as overhead Additionally 100000 is the minimum value recommended for Memory allocated for buffers even when you use extended memory buffers If you allocate more extended memory buffers than are available the following message at software startup indicates the actual number of extended memory buffers available Only nnnn Kbytes of extended memory is available for use If you allocate too many extended memory buffers meaning the overhead required for the extended memory buffers exhausts the amount of conventional memory you will see this message XMS Buffers Not Allocated Not Enough Real Memory BARR R
597. to return to the Devices and Printers menu 108 8 10 LANI LAN4 Devices LAN Connection Options gt From the LAN Connection screen for the selected LAN device select Options LAN1 Connection Check Read directory for new files every 30 seconds Read directory Retain directory Delete old Retain directory files No Retain files for 7 days Start JCL file End JCL file oo i oO S o a 2 Ss Z me Ss e a Enter number Check Read directory for new files every seconds Specify how often BARR RJE checks all the LAN connections directories for files The default interval is 30 seconds You can adjust this value from any one of the LAN1 to LAN4 screens and the change is reflected on all four screens Read directory Specify the name of the directory containing the files to be routed Include the drive letter and the full directory path You can specify a different directory for each LAN device Files are removed from this directory after they are routed Note If you only specify a drive letter the current directory will be used not the root directory To avoid confusion and potential errors when you change the current directory specify the complete file path You can follow the directory name with a forward slash and any of the send modes described in section 21 4 BARR RJE 109 Note When you use LAN connections to send files to the ho
598. tory Route a file to one of eight different destination devices such as a PC printer network printer or network directory Reprint an entire file or portions of a file after resolving a printer jam a Save or retain a copy of a file after it prints restore the file to the print spool if you need to print it again and automatically purge the retain directory at regular intervals to free PC disk space m Log print spool activity so you have a record of when files were printed reprinted deleted or restored This chapter describes how to set up the Barr print spool For more information about print spool features applications and operation see Chapter 24 Print Spool Operation BARR RJE 119 KAN How the Print Spool Works Z i o N o a i A a oa This section describes how the print spool uses file attributes printer attributes and device assignments to direct files to destination devices Files from One Source Write to Different Destinations Suppose you want to write files from an RJE print stream to PC printers If you do not use the print spool the software routes all files from one source device to the same destination as shown in Figure 9 1 _ T l M P z a Mainframe PC Printer Figure 9 1 Without print spooling all output from the PR1 print stream prints on PC Printer 1 If you enable the print spool you can route different files from
599. ture best meets your printing needs Use Barr FCBLOAD Choose whether to enable the Barr FCBLOAD mechanism which uses the Forms Control Buffer FCB information supplied by the host computer The FCB contains information used to format the data at print time including lines per inch lines per form and carriage control stops As a file is being received the format information is stored in the Barr spool header When a file is ready to print BARR RJE BARR RJE 281 converts the spool header to commands and sends them to the printer ahead of the file You also must enable the FCBLOAD feature at the host so that FCB information is included with each file received from the host to the PC For JES2 and JES3 enable the LOGMODE s PSERVIC parameter For JES2 also enable the FCBLOAD parameter on the Remote Printer statement You cannot use the host SETUPHDR feature if FCBLOAD is enabled at the host See Appendix F Form Information Sources for more information about using FCBLOAD and how remote and local FCB handling differ No Default Discard the FCB information from the host if any If you use the host SETUPHDR feature you must disable the FCBLOAD mechanism in the Barr software and at the host computer SETUPHDR and FCBLOAD cannot be used together Yes Use the FCB information from the host to set the lines per inch lines per form and carriage control stops This information is stored in the file s Barr spool header a
600. tware puts it on hold because of an error condition BARR RJE stores the reprint repositioning information in the file s spool header It uses this information to determine where reprinting should start when printing resumes When you set the file and printer for reprint BARR RJE automatically repositions the file to the top of the page where printing stopped Note If the file has no page breaks BARR RJE repositions it to the line immediately before the one where it stopped printing If BARR RJE does not locate at least three page breaks within the first 600 lines of the file it treats the file as if it has no page breaks From there you can use commands to position the file to the desired reprint start point N A mi 3 N g 2 3 e S i For optimum reprint repositioning for large files enable the Save fast reprint repositioning option on the print Spool Description s Advanced Spool Options screen BARR RJE 425 o i i 72 pan i Q N Reprint commands display at the bottom of the Reprint screen Page 1 Line 1 column 1 File TAX1040 1 PRT JOB 8000 1236 5 1 500 BARR MSGCLASS A JOB 5684 k 8000 1236 CPU SECONDS LINES 1000 PUNCH FORM COPIES KKK JOBPARM LINECT 0 2 EXEC PGM IEBGENER 3 SYSIN DD DUMMY 4 SYSPRINT DD SYSOUT A 5 SYSUTL DD 6 SYSUT2 DD SYSOUT A DCB BLKSIZE 80 RECFM FA Besssss
601. tware rebuilds each record by combining the specified number of lines The EBCDIC data from the host is converted to ASCII format with a carriage return and line feed CR LF to indicate the end of each record but no form feeds are added FF to indicate page boundaries When you select N ASCII lines you are prompted to specify the number of 80 character lines that should be combined into one record Choices are 1 to 9 where 9 allows a maximum record length of 720 characters For the MVS JES2 MVS JES3 and VS1 RES systems another solution is to use the BARR TRAN mainframe program This program is provided on the Barr software disk and is usually installed in the C BARR TRAN directory BARR TRAN can transfer records of any size For more information about using BARR TRAN request the BARR TRAN manual from Barr Systems _ A 2 5 S o 7 DOS obsolete Obsolete selection This option serves as a place holder to enable configuration files from older versions of Barr software to remain compatible Use the Transfer files receive mode instead Variable ASCII lines A method for receiving variable length or fixed length records that are shorter or longer than 80 characters Variable length records have different lengths while fixed length records have the same length Some host systems can transfer only 80 character records If you need to transfer records with a different length the Variable ASCII
602. u which reflects the new assignment Mount Forms oo im 53 o Bal i 3 an Select printer PR1 gt CHECKS Escape PR2 PERF Selection l gt 5 Follow the same procedure for mounting forms on any other RJE printers you enabled 6 When you finish assigning forms select Escape or press to retum to the Printer Forms menu EER Printer Forms Commands Sent to Host The Printer Forms feature includes an option for automatically sending commands to the host computer when a form is mounted These commands help control the printing of jobs that need forms If your host computer requires form commands and you do not enter them here you must issue commands manually from the Operation screen RJE systems such as MVS JES2 associate a form name with each print output file The RJE system also associates a form name with each RJE printer Print files are automatically sent to the remote PC when the form name for the file matches the form name currently assigned to the remote print stream Other selection criteria also might be required to match such as the job class or priority Printer commands are used to set the criteria on the RJE print stream so that the form on the host print stream matches the form name of the jobs you want to receive BARR RJE 237 a E ras o p a Gr _ gt To reach the command entry screen from the Printer Forms screen s
603. ues while they wait to be printed Queues reside on network file servers The software uses NET devices to write files to the network print queues For each NET device you can route all output to one print queue on a specific file server or you can route output to different print queues on any server by using the print file s FCB name or form name as routing criteria The number of Novell print queues you can access is determined by the number of NET devices you define and the number of entries you make in the FCB FORM to Print Queue Translation Table Network Connections The Novell network allows a PC to connect to a maximum of eight different file servers at a time For the NET devices the Barr software BARR RJE 77 logs into and out of servers as needed to access additional queues The software connects to the servers as a network user with print queue rights Of the eight possible server connections the number available for the NET devices depends on how many server connections are being used for other purposes The PC can log into file servers when you power it on before the Barr software starts These server connections are used to access network drives and BARR RJE cannot log out of them The Barr LAN connections feature can use these connections If you receive data on the Novell NetWare queue devices NW_QUEn described in section 8 11 BARR RJE will use another network connection For the Novell queues the software
604. ull duplex that is it sends and receives files simultaneously Full duplex nearly doubles throughput when the software sends data in both directions Full duplex communication is achieved by configuring communications devices for DUPLEX FULL and setting the VTAM parameter DATMODE FULL Most other SNA products operate at half duplex even though dedicated lines and many dial up modems for example V 32 are set for full duplex Although you might only need to transfer files in one direction responses must flow in the other direction too With half duplex receiving pauses while responses are sent With full duplex you can send responses without delay For one way file transfer full duplex can increase throughput by up to 20 percent Satellite Communications On a satellite link turnaround delays are long because of the distance the signal must travel between the satellite and Earth Signals travel at the BARR RJE 27 speed of light Full duplex eliminates line turnaround delays and might increase throughput as much as 150 percent Satellite communications require radio waves to travel 50 000 miles from Earth to the satellite and back to earth Signals travel at the speed of light which is 186 000 miles per second Because of this distance and typical ground delays of 0 1 second a 0 8 second delay is introduced between sending a frame of data and receiving an acknowledgment an gt 2 ras wi gt es n c
605. umber iv 401 setup 261 SYNC ISA 263 264 synchronous 10 test failure 269 testing 266 token ring 10 14 type 200 V 35 263 video 199 201 Adapter manuals 4 Adapter open scope character 369 ADF files 40 Advanced Function Printer AFP printers 31 Alarm printer error 59 Alerts NetView 395 operator generated 397 Alt Function Key Definitions screen 248 249 Alter Device command VSE POWER 486 Alternate token ring adapter 299 Anacomp Datagraphix 32 XFP 2000 32 BARR RJE 551 Analog loopback mode 265 ANSI carriage control standard 220 printers 93 Any key prompt 34 48 Append files option 165 173 Application program packaging BARR RJE 25 455 running from BARR RJE DOS session 311 APPLID 18 AS 400 10 32 ASA carriage control 187 erting to machine Ers 439 509 ASTU 7 bit 64 character set 185 control characters 293 converting to EBCDIC 451 extended 58 94 492 format 489 input mode 68 70 receive mode 177 178 send mode 342 translate control codes 293 ASCII delete 7F characters remove 294 ASCII to EBCDIC 29 codes 495 screen 279 table 273 278 293 493 ASCII to EBCDIC conversion serial port 68 69 Assign devices 26 Continue option 160 175 disable 311 during operation 348 Receive mode option 177 screen 151 152 Assign Devices Options screen 186 Assign Translation Tables to Devices screen 280 Asterisk receive mode indicator 177 197 Async connection message 363 return code 363 Asynchronous
606. unch device 1 Typically data re ceived on the punch is processed rather than printed punch Output from the host computer that consists of a file of lines up to 80 characters long queue A list of items waiting for service in a system RD1 RJE reader device 1 reader A logical device that reads jobs from the RJE workstation and sends them to the host system At the host jobs are placed in a job queue for processing receive To obtain data from a communications line in contrast to send receive mode Options that control the format of files that are received RECFM Record format The definition of how data is structured in the records contained in a file The definition includes record name field names and field descriptions such as length and data type Record formats can be fixed length variable length or unspecified length record A logical grouping of data such as all information relating to a particular account remote A terminal attached via a communications link to a mainframe computer remotely attach To connect equipment to the mainframe via a telecommunication line RJE Remote Job Entry A computing environ ment in which you can create programs and data offline on the PC transmit them to the mainframe receive the printouts at high speed on disk or printers and con trol the status of jobs with remote opera tor commands Messoj9 BARR RJE 545 RS232 Refers to EIA Stan
607. up to 20 entries with the standard software or you can request a software version that enables up to 100 entries 136 9 5 File Attribute Table FAT external Maintain the FAT in a separate file that loads into extended memory XMS when you start the software You can view the table during software operation and edit the external file with an ASCII editor Use this choice if you need to make more than 100 FAT entries See section 9 6 Maintain an External FAT File for information about creating and modifying the FAT Note The software cannot convert an internal FAT to an external FAT file To change from an internal table to an external FAT file you must print the File Attribute Table screen from the Installation Description and then re enter the information in an external FAT file o im 5 N 2 i D a ir 3 Ej External FAT file name For an external FAT specify the name of the file that contains the FAT entries Include the full directory path How the Table Works This section describes how table entries are applied to files Two Part Entries Each line in the FAT is a separate entry and each entry has two parts file match criteria and file override values In the default internal table shown below Filename and Form are the match criteria and State Class Prty Copies and Disposition are the override values The table headings depend on your selection for the Match FAT entr
608. ur PC hard drive fails or becomes corrupted you can quickly put a configured copy of software into production instead of re installing and re configuring the software To distinguish the configured backup copy from an unconfigured backup copy you might want to rename the file For example from the DOS prompt type the following copy c barr barrsnar exe a rjeback exe BARR RJE 317 EEX Using Configuration Files You can use configuration files at program startup This section tells you how to use the configuration files you created Chapter 20 Software Startup discusses program startup Specify a Configuration File To use a configuration file at program startup specify the startup command at the DOS prompt followed by an character and the configuration file name For example barrsnar daily cfg Use the Default Configuration File If you use the default configuration file name BARR CFG include just the in the startup command you can omit the file name For example these two commands produce the same results barrsnar barr cfg barrsnar Modify a Configuration File To modify a configuration file you created earlier specify the installation startup command followed by the character and the configuration file name at the DOS prompt For example 19 Exit and Save barrsnar i daily cfg When you select Exit and Save Changes remember to set Save parameters to a configuration file to Yes Save Co
609. ure or the form name will be discarded BARR RJE searches for a user defined form that matches the form name in the OUTPUT statement If it does not find a user defined form the software displays this message 188 10 9 Options for Assign Devices Class n OUTPUT statement received but form nnnnnnnn not found The form name in the spool header is set to blank but any other OUTPUT statement fields are applied You can use the Ignore n lines from start of file option with the OUTPUT statement Use this option to assign an output class to a file received on a given source device The RJE system does not provide class infor mation when it transfers files to a remote The software assigns a default class and displays it in this field but you can change the default value The class can be a letter or number _ A 2 5 S o D 2 The specified class value is saved in the spool header displays as a file attribute on the Print Spool screen and can be used as part of the criteria for routing spool files to printers You can set a different class value for each source device A common application is to assign the source print stream PR1 a class value that matches the value used at the mainframe The default classes are consecutive numbers for all devices except the RJE punch which is assigned a letter For example default classes are 1 to 7 for PR1 to PR7 and to V for PU1 to PU4 You also
610. urs after the specified time it connects immediately rather than waiting for the next occurrence of the starting time ob oo im gz i 5 an When you enter a start time use the 24 hour scheme where for example 1 a m is 01 00 and 1 p m is 13 00 Verify that the time on your PC is correct use the DOS time command to ensure that the connection will be made at the specified time If you use a start time a message indicating the start time displays on the PC console when you start the software The format of the message is Waiting until hh mm to start communication Current time hh mm If you use an autodial modem you can specify the connection start time either on this screen or under Modem Type and Dialing Instructions on the Modem Options screen The value you enter displays on both screens BARR RJE 295 a i A i o r Communication role Select whether the PC will perform the communication role of the remote or the host Remote Default BARR RJE assumes the role of the remote PC This is the normal role for connecting to the host computer Host BARR RJE assumes the role of the host computer This mode is useful for connecting PC to PC where one PC must be in remote mode and the other one must be in host mode When the PC assumes the host role it waits for the INITSELF command from the device configured as the remote before it sends a bind If t
611. used as data so the PI line is idle The D P I selection supports up to 255 print lines per page and carriage control stops appearing on lines 1 to 240 i S o D N 2 3 3 m 5 D R a Genicom D P I No LPI This printer type is similar to the D P I selection but does not send the lines per inch setting to the printer Use this selection for printers that supply the lines per inch setting but need the software to set the lines per form The Genicom 1255 is an example of such a printer Lines per form and Lines per inch Control codes also called escape sequences are used to specify lines per form lines per inch and other format settings for printers Your printer manual describes the control codes used for your printer Barr software supplies the most common codes used for various printers See your printer manual for a list of the control codes your printer supports Table 8 1 shows common control codes for the printers listed on the Choose Printer Type screen Values for lines per form and lines per inch are provided either by form information in the original file or by a form you created with BARR RJE These values are stored in the Barr spool header When the software sends data to the printer it interprets the value for these settings and sends the corresponding escape sequences to the printer If the host computer supports the FCBLOAD option FCBs can be used to include lines per form and lin
612. ut of the job named MYJOB from hold BARR RJE 473 0 J357 releases the output of job 357 from hold P Purge The P command stops device or job activity after the device or job completes the current activity If the operator specifies a job the software flags it for purging If the job is inactive the software purges it If the job is active it completes its current activity and then the software purges it If the operator specifies a device the software drains the device if it is inactive If the device is active the software sets it to drain Then the device completes its current activity and drains A device in the drained state will not start until the operator starts it Operators must use the P command to cancel a job on the output queue because C will not work Format Operators can specify a job number to purge or device to drain with the P command P Jnnnn where nnnn is the number of the job to purge P dev where dev is the device for example PR1 RD1 or PU1 to drain Examples P J333 purges job 333 CA D c lt x P PR2 drains printer 2 P RD1 drains reader 1 474 A 1 JES2 Remote Commands R Route The R command routes a job s output the same way a ROUTE statement in JCL does Operators can route the print or punch output of a job under their jurisdiction to another remote or to the host computer Format The operator ca
613. utput to parallel or serial ports Parallel ports are called LPT1 LPT2 and LPT3 Serial ports are called COM1 COM2 COM3 and COM4 You can also assign RJE print streams to write to network printers or to PC disk files During program operation you can assign RJE printers to any PC DOS devices Electronic Forms Management Barr software brings electronic forms management to the PC Electronic forms eliminate the need for pre printed paper forms and simplify RJE operation reduce operating costs and increase flexibility You can compose change and update forms on your PC with a forms composition program You can also distribute electronic forms via the mainframe RJE network to all PC print stations Barr software automatically loads forms into the printer when you receive a file from the mainframe For more information about using electronic forms with Barr software request the Electronic Forms Management booklet from Barr Systems BARR RJE 21 Special Forms Support You can use BARR RJE to print on special forms such as checks and invoices You can store up to 100 forms in the program or you can download form information from MVS JES on the mainframe via the FCBLOAD mechanism You can request a special version of the program that supports 200 forms BARR RJE also provides high speed printing support for the Dataproducts and Centronics Vertical Forms Unit VFU feature an gt 2 ras wi gt es n cc cc
614. via a modem you need an external synchronous modem For an asynchronous connection to BARR GATEWAY with the Barr ASYNC option you need an asynchronous modem EEJ Package Contents Your BARR RJE package includes the following software hardware and documentation If you purchased Barr communications hardware or other hardware and software options see the corresponding hardware or option manuals for a list of additional items included BARR RJE Software The BARR RJE software disk includes program files and reference files If you purchased additional software options the BARR RJE disk includes additional software Barr Hardware For SDLC X 25 or Coax host connections a Barr communications adapter and cable are included For an 802 2 token ring host connection a hardware key is included The communications adapter enables your PC to communicate with the mainframe or host computer The hardware key is a small device for software protection that plugs into a PC parallel port You can attach a printer cable to the other end of the hardware key BARR RJE 3 1 Introduction BARR RJE Manual The BARR RJE manual tells you how to install and operate the PC software Host Definition Guide You get two copies of the Host Definition Guide One copy is for your use Give the other copy to the mainframe or host systems programmer BARR RJE requires that the host programmer enter specific host parameters at the host computer T
615. w the last field See the external FAT file example earlier in this section for examples of how to use commas i o N o a i A a oa Follow these guidelines for the state and disposition fields Guidelines for other fields are given under FAT Criteria in section 9 5 State Field Values Valid values for the state field are Ready and Hold The software only looks at the first character of the field If you specify R or r as the first character the file state is set to Ready If you specify H or h as the first character the file state is set to Hold Disposition Field Values Valid values for the disposition field are Delete and Retain The software only looks at the first character of the field If you specify D or d as the first character the disposition is set to Delete If you specify R or r as the first character the disposi tion is set to Retain Default Entry Line The last entry line of the FAT file is used as the required default entry Values from the default entry line are applied to any files that do not match entries in the table Note You must enter a default line even if you do not plan to use it If you do not want the default entry to affect any files enter the word default in the first column of the entry line and leave the rest of the entry line blank For more information about using the default line see How the Table Works in section 9 5 146 9 6 Maintain
616. ware functions at different times For example you might want the software to operate differently during the day than it does at night Configuration file Specify a name for the configuration file BARR CFG is the default name Using CFG as the file extension for your configuration files makes the files easy to identify Leave this field blank if you do not use configuration files Section 19 4 provides additional information about configuration files EER Exit Options Screen 1 Complete the options on the Exit and Save Changes screen and press Enter The Exit Options screen displays 316 19 2 Exit Options Screen Exit Options Begin communication at Operation screen Exit to DOS Return to Installation Description Selection l gt 2 Choose one of the displayed options Begin communication at Operation screen Start the BARR RJE program The Operation screen displays while the software connects to the host Chapter 20 Software Startup discusses program startup Exit to DOS Exit the software and return to the DOS prompt Return to Installation Description Go back to the Installation Description menu to make additional changes aheg pue XF 6L EEE Copying the Configured Software When you finish saving your configuration changes copy the configured software to one of these locations a A disk A directory on the network A directory on another PC If yo
617. ware to define form information and use the SETUPHDR PDIR information from the host computer to trigger automatic loading of the Barr form This method provides the most reliable information and is the preferred method for most sites It is also the best method to use if you plan to print multiple copies of a job See section F 2 FCBLOAD with HASP190 Use the FCBLOAD feature on the host computer to obtain format information and use the HASP190 message to supply the FCB name or form name Use this method if the forms at the host are too numerous to define in the Barr software and the host forms are compatible for remote printing See section F 3 Edit Forms with Manual Mount Forms Use Edit Forms to define the form information The operator manually controls forms loading before jobs are received Use this method if the first two options for obtaining form information are not available See section F 4 Z i E i E L L 514 F 1 Obtaining Form Information Other Ways to Obtain Form Information For Oc and Xerox channel attached printers you must obtain format information by other means Oc Channel attached Laser Printers Oc printers load form overlay files that contain format information The form name from the host determines which overlay file is used Instead of defining printer forms you must create overlay files for Oc printers For more information about form overlays se
618. ween the PC and Host BARR RJE can send data from the PC to the host computer and receive data from the host computer to the PC You can issue commands to the host computer from the PC keyboard BARR RJE sends files or jobs from the PC to the host on a host reader device In turn the host sends BARR RJE 149 _ A 2 5 i S o D 2 command responses or operator messages to the PC where they display on the PC console BARR RJE receives print files from the host to the PC on the RJE print stream or printer Usually data files to be processed by application programs are received to the PC from the RJE punch stream or punch p command to host COMMAND to host reader RD1 g z console message CON S from host printer PR1 3 from host punch PU1 Mainframe PC Figure 10 1 You can send commands and files from the PC to the host computer and receive command responses and files from the host computer to the PC Data Flow between the PC Devices and the LAN BARR RJE can send data from the PC to PC devices or to the LAN For example it can send a PC data file to a PC printer a network directory or a network printer Additionally BARR RJE can input data to the PC from PC devices or the LAN For instance you can input a file to the PC from a LAN directory or from a device connected to the PC serial port 150 10 1 Data Flow to and from the PC input from s
619. when it finishes sending files and receiving printouts 6 The application program can terminate or continue with other tasks Changing Your Application Program Code Change your application program code as described in this section BARR RJE 455 Batch SHELL You can implement the packaging structure by using batch files or the SHELL construct in the BASIC PASCAL C or COBOL computer languages Enter the following command in your program barrsnar files In this command files represents the names of the files to send to the mainframe Exit To cause BARR RJE to exit after it sends and receives files access Tuning and Global Options Restart Actions from the Installation Description screen and make the following selections Restart Actions Disconnect if idle Yes Idle time period 30 seconds Exit from program after disconnect Yes Reconnect periodically No Reconnect time interval _ Enable FNA Termination Sequence No Choice ERRORLEVEL In your batch file you can test the value of the DOS ERRORLEVEL parameter and specify an appropriate action BARR RJE sets the ERRORLEVEL as defined in DOS If BARR RJE completes its task it sets the ERRORLEVEL to 0 If the transfer does not complete normally it sets the ERRORLEVEL to 15 See the IF statement under Batch Commands in your DOS manual a i 2 Z lt 5 o o Z pej N For example if
620. will log into one file server as a print server This connection is different from the user connection made by the NET devices During software operation BARR RJE will not log out of the Novell queue connections either Because Novell does not allow a PC to log into the same file server as both a user and a print server the NET devices cannot access the same server used by the Novell queues n o 2 E a 3 G a a Fq oa Options for Novell Print Queue If you select Novell Print Queue as the NET device network type the following options display on the lower half of the screen Network Printer Options NET1 network type Novell Print Queue printer type Generic NET1 File server Print queue Use name entered above for print queue name Use Novell print banners Yes Banner name is username File name is jobname Use Novell form numbers No Add form feed between jobs Yes Enter character 78 8 5 NETI NET12 Devices Use for print queue name File server Print queue If you want to route all output for the NET device to one print queue enter the File server and Print queue names When you route output for this NET device to many devices by FCB name or form name you can leave these fields blank or you can enter a default value in case of an error condition See FCB FORM to Print Queue Translation Table later in this section The software can be
621. xed Length EBCDIC 370 Channel Transparent Translation Table Menu gt To reach the translation tables in the software from the Tuning and Global Options menu select ASCII and EBCDIC Translation Tables BARR RJE 273 ASCII and EBCDIC Translation Tables Translate control codes to Control codes as in Appendices B 4 and B 5 Translate control codes to Question marks normal case Choose Language for translation tables Edit translation tables Assign translation tables to devices Escape Selection tJ Choose from the following options Translate control codes to Control codes If your data includes control characters select Translate control codes to Control codes to enable special features of your printer This selection allows BARR RJE to translate control codes that are embedded in the data Note Do not confuse control codes that are embedded in the data with control codes that precede data records Control codes that precede data records are processed differently they do not go through the translation tables a i A i o For example the HP LaserJet printer uses escape sequences to print boldface text or different fonts If you embed these types of codes in the data the codes will be translated according to the Barr transla tion tables When data is transferred from the PC to the mainframe computer the ASCII control characters 00 to 1F are conve
622. ximum line length is limited to 80 characters you might not be able to specify all of the possible options Use these keywords to set options in the OUTPUT statement and substitute the option value for n FILENAME n JOBNAME n FORMNAME n FCBNAME n COPIES n PRIORITY n CLASS n DISP n ASCIASA n You cannot abbreviate the keywords Use the DISP field to specify the disposition the file will have after it prints To retain the file specify DISP R To delete the file specify DISP D Use the ASCIIASA field to specify how to handle ASA carriage control for ASCII files you send to S 370 channel printers requires the PRINT370 option Specify ASCITASA Y to convert ASA carriage control to machine carriage control Specify only the options that you need You can list the options in any order For example OUTPUT FORMNAME taxes FILENAME taxdata If you specify FILENAME its value it will be used as the Ending of file name You can use the Ending of file name is from file feature to obtain the file name from file text and use the OUTPUT state ment to supply other options For example you can use Ending of file name is from file to extract the file name from the banner page and use the OUTPUT statement to assign a form name If you specify an invalid file name the software assigns the file name ERROR and displays an error message on the console When you include FORMNAME in the OUTPUT statement you also must use the Barr Edit Forms feat
623. ximum number of LUs 99 Constant RTS No Ignore DSR 0 No Drop DTR on exit Yes Full duplex multi drop line No Line speed when using SME cable 9600 Token Ring Adapter Primary PC Service Access Point 04 Token Ring Max Out 2 Token Ring Max In 1 Number of Gateways in GatePool 0 Method of Gateway Pooling Statistical Netview Alerts No Enter number 294 18 4 Modem and Line Control The options on this screen fall into four categories options that affect all communication links options that affect the SDLC link options that affect the 802 2 link and options for workstations that connect to the host through the BARR GATEWAY See the Barr Host Definition Guide for more information about communication links Options for All Communication Links You can use these options with any communication link Start communications at time Use this option for delayed communications startup This option is useful for unattended operation especially when you are connecting to the host computer after normal business hours to take advantage of lower communications charges Normally you do not need to enter a connection start time If you leave this option blank the Barr software immediately tries to connect to the host computer when you start it If you specify a starting time when you start the software it waits until the time indicated to make the connection If you start the software within eight ho
624. y in the first portion of output sent to the printer For example if the operator selects Print Test Page and then starts reprinting the job the spool header infor mation is sent only with the test page It is not sent again when the file begins to print Choose this value if sending the spool header more than once causes problems for your printer o im 5 N r 2 i D a ir 3 Ej No When you use the reprint operation the spool header is included with each portion of the output sent to the printer Choose this value if your printer requires the spool header for each portion of output Save fast reprint repositioning information This option controls how files are repositioned for spool reprint operations Choose whether the software stores repositioning information as it prints each spool file to help it quickly reposition the file in case you use the reprint feature Your selection depends on the size of the files you need to reprint No Default The software does not store repositioning information If you reprint the file the software starts at the beginning of the file and advances page by page until it finds the last print offset the line where the job stopped printing This method works best for reprinting most files Yes As a file prints the software keeps track of the last page printed in case it needs to reposition for reprint operations If you reprint the file the software instantly loca
625. y to RJE sessions If you have RJE 3270 you can set these options for your 3270 sessions Printer error time out in minutes 3270 printers use this option to alert the host if the printers are offline or out of paper longer than the specified timeout period The default timeout period is 10 minutes For 3270 printers reset FCB to default at end of file Choose whether to use the previous FCB or a default FCB at the start of a 3270 print file No Default Load the previous FCB at the start of the file Yes Load the internal Barr default FCB at the start of the file This resets the printer so the previous FCB is not used for files that do not require FCBs a i A i o r 18 3 Reader Control Reader Control options allow you to adjust the format of files sent to the mainframe computer on the reader devices RD1 to RD4 gt From the Tuning and Global Options screen select Reader Control Reader Control Minimum reader line length 1 Maximum reader line length 80 Interpret characters 89 8A 8C 8D 9A and FF as ASCII 09 0A 0C 0D 1A and 7F Yes Strip ASCII delete characters 7F from file Yes Enter number 292 18 3 Reader Control Minimum reader line length Specify the minimum length of data lines that will be sent on the reader Any data lines shorter than the minimum line length will be padded with blanks to the specified length For host computers th
626. y you do not need to change these options unless a Barr Technical Support analyst instructs you to do so Token Ring Adapter If two token ring adapters are installed in your PC for communica ting with different networks specify whether the Barr software will use the Primary or Alternate token ring adapter This setting is usually configured with a jumper or DIP switch on the token ring adapter This option is useful if BARR RJE communicates on only one of the networks while other PC applications use a second network If you need to communicate with two hosts on different networks you can use different configuration files to communicate with each host Primary The Barr software uses the primary token ring adapter Alternate The Barr software uses the alternate token ring adapter ob oo im kzi i gt an PC Service Access Point Specify the PC service access point SAP used to communicate with the host computer The SAP allows multiple independent connections to the network using one physical adapter address The default value is 04 Other choices are multiples of 04 up to the maximum of EC Token Ring Max Out Specify the Max Out value for the token ring logical link control LLC driver Max Out is the maximum number of sequentially numbered frames that can be transmitted before an acknowledg ment must be received Valid values are 1 to 127 The default value is 2 If Max Out is set to 0 the def
627. you load the INSTALL program BARR Systems Inc Installation Software Will this be an Update or New Installation Update New Installation a Press U for Update if you already have the Barr software and are installing a new version Press N for New Installation if this is a new Barr product If you select Update the following warning screen reminds you to save the configuration settings from the old software before you continue BARR RJE 41 WARNING Before updating you should bring up your old software and save the configuration to a configuration file To do this follow these steps Step 1 Exit install program Step 2 Enter lt Program Name gt I Step 3 Select Exit and Save Changes Step 4 Answer yes use to toggle yes no to the question Save parameters to a configuration file Step 5 Enter a configuration file name You will be prompted for this name later in the install process Step 6 Restart install program S T S B S 7 o Please enter choice Continue with update Exit b If you do not want to save the settings now press C to continue To save the configuration settings before continuing read the instructions on the screen press E to exit the install program and then perform the steps from the DOS prompt 4 Choose which files to install After you choose Update or New Installation the i

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`utilisation  significado de los leds    Gesa  bedienungsanleitung vx-200 vibrationsplatte  Raidon GT1650-WSB3 storage enclosure  Dell G2410T User's Manual  Serie 93 Manual Utente, Termoregolatore a  Guia rápido de instalação T3A-D8182DB - Wiki Karat  平成ー6年、全国で2664件の踏み間違い事故 なんと、毎日約2ー件の悲  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.