Home

Anaheim Scientific M120 Mini Temperature/Humidity Meter

image

Contents

1. normal measurement press MODE button to switch temperature Dew point Wet bulb in sequence 6 2 CAL C F Button Calibration point 55 RH and 25 C 1 Prepare the 55 RH and 25 C environment 2 Press CAL button and POWER button for more than 2 seconds to calibrate anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 3 Put the meter in the calibration environment 4 Presses the MODE key to select humidity or temperature humidity and temperature must be done individually 5 Press CAL button more than 2 second to complete the adjustment ai 6 To exit calibration mode press the H key Press this button to alternate between C and F units 6 3 MAX MIN AVG Button The MAX MIN feature reads and updates the display to show the maximum or minimum or AVG value measured after you press the MAX MIN button Pressing the MAX MIN button for less than 1 second will put the meter into a mode of displaying the maximum minimum average readings Each time the MAX button is pressed the meter will cycle between MAX and MIN and AVG readings Press the MAX MIN button for more than 2 seconds to exit this mode 6 4 Data Hold Button Press the HOLD button to enter the Data Hold mode The LCD will display the HOLD symbol and hold both the temperature and humidity readings at the same time Press the HOLD button again to exit this mode anahemm
2. AKNAHEIM SCIENTIFIC User Manual Model M120 Mini Temperature Humidity Meter CAL MAX MODE C F MIN HOLD Table of Contents 1 INTRODUCTION MN 3 1 1 The M120 EE 3 2 SAFETY SUMMARY EE 4 3 COMPLIANCE STATEMENTS cccccccccseseeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 5 4 PRODUCT CONTENTS AND INSPECTION cesseseeseeeeeeeeeeeeee 5 5 DEVICE DESCRIP THON ssssssecctsicsstecesseritzisasasasdsensusnanrosasisseieretorecisecs 7 5 1 Meter Control BO cccsssitcccttanssndvaascenticccavitaateasucntuuudsuadoawesss 7 5 2 LCD Display EEN ees geesde 8 6 DEVICE OPERATION ssiicscacceattuietnctedepeiteisabtianbalsscasastdneadwentehurencetant 8 6 1 Switching MOOG asec cose sant cadansccctscistaadeaaandecegececieeeeeeeectecceeedtens 8 6 2 EIERE EEN 8 6 3 MAX MIN AVG Lt WEE 9 6 4 Data Hold Button enee eet 9 6 5 Power BUOM srs e e e eaea 10 6 6 Auto POWE E 10 6 7 Battery EH ebe gegeegedeg inerentas sennie rasanne 11 7 TECHNICAL SPECIFICATIONS ccccceeeeeeeeeeeeeeeeeseeeeeeeeeeeseeeeeees 12 8 SERVICE REPAIRS CALIBRATION cccccssesseeeeeeeeeeeeseeeees 13 9 LIMITED TWO YEAR WARRANTY ssssesessssseeeeeeeeeeeeeeeees 15 anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 1 Introduction Thank you for purchasing a M120 Temperature Humidity Meter from Anaheim Scientific The M120 uses a highly accurate sensor chip to measure relative humidity and temperat
3. e for Non Warranty Service does not include return anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 14 shipping Return shipping to locations in North American is included for Warranty Service For overnight shipments and non North American shipping fees please contact Anaheim Scientific Anaheim Scientific ATTN Service Repair 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 15 9 Limited Two Year Warranty Scientific warrants to the original purchaser that its products and the component parts thereof will be free from defects in workmanship and materials for a period of two years from date of purchase Anaheim Scientific will without charge repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date in the form of a sales receipt To help us better serve you please complete the warranty registration for your new instrument via our website www anaheimscientific com Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed Anaheim Scientific shall not be liable for any consequen
4. r chemical solvent like alcohol when cleaning Do not place the Temperature Humidity Meter inside any liquid to prevent damage to the Thermometer anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 3 Compliance Statements Caution This symbol indicates that the equipment and its accessories shall be subject to separate collection and disposal procedures EMC C EMC EN61326 1 This product complies with requirements of the following European Community Directives 89 336 EEC Electromagnetic Compatibility and 73 23 EEC Low Voltage as amended by 93 68 EEC CE Marking However electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference 4 Product Contents and Inspection This unit is tested prior to shipment It is therefore ready for immediate use upon receipt An initial anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 6 physical inspection should be made to ensure that no damage has been sustained during shipment Inspect the packing box on receipt for any ex
5. rranty Validit Above specifications tested at Temperature 25 C Humidity lt 90 RH anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 13 8 Service Repairs Calibration The following are instructions regarding policies for servicing repairing or calibrating Anaheim Scientific products Turnaround time is usually less than ten 10 working days unless expedited service is requested and pre arranged Send an email to service anaheimscientific com requesting an RMA number specifying your request for either service repair and or calibration with your product s model number Once you receive a reply from service anaheimscientific com you will be asked to ship prepaid to the address below Package the unit carefully using filler or bubble wrap and if possible ship in the original box Ship each unit separately Anaheim Scientific is not responsible for any shipping damage that may occur Include a packing list with each unit shipped stating what type of service is required and include the return shipping information name address and telephone number lf the unit is in warranty please provide the following proof of purchase or copy of the original invoice lf the unit is out of warranty prepayment is required by Check Money Order or Credit Card Return all merchandise to Anaheim Scientific with pre paid shipping The flat rate repair charg
6. scientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 10 6 5 Power Button Press the H button more than 2 seconds to power on the meter 6 6 Auto Power Off To save battery life the meter powers down automatically after approximately 12 minutes of inactivity You can disable or enable Auto Power Off by pressing the D button more than 2 second the LCD symbol will disappear or appear anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 11 6 7 Battery Replacement WARNING If the symbol Ch appears on the LCD please replace the battery immediately Remove the battery cover Replace the battery Install the battery cover dein Deet SE anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 12 7 Technical Specifications Dual LCD display The maximum value on the primary display is 999 The HR maximum value on secondary display is 999 sampling 1 sample per second R R Measuring 20 0 C 50 0 C 4 0 F 122 0 F 1 0 99 RH at a o u e nge Humidity 3 5 for 20 90 Accuracy 5 for 1 19 9 and 90 1 99 Temperature 1 0 C 1 8 F Supply Battery life 50 hours during consecutive use Dimensions 107 x 48 x 23 mm H x W x D Weight 80g excluding the battery Limited two year wa
7. ternal damage If any external damage is evident remove the instrument and visually inspect its case and parts for any damage If damage to the instrument is evident a description of the damage should be noted on the carrier s receipt and signed by the driver or carrier agent Save all shipping packaging for inspection Forward a report of any damage to the agent through which the unit is procured Retain the original packing in case subsequent repackaging for return is required Use of the original packing is essential After the mechanical inspection verify the contents of the shipment The items included in this package are M120 Meter User Manual Carrying Case 2 x AAA Batteries anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 5 Device Description 5 1 Meter Control Buttons Sensor LCD CIE Temperature unit and calibration button DEW POINT WET BULB Temperature button MAX MIN AVG Reading button Data hold button On Off button anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 5 2 LCD Display Functions Low Battery Detect Primary Display Secondary Display Auto Power Off Indicator Data Hold MAX Data Hold AVG Reading MIN Data Hold Relative Humidity C Temperature unit DEW POINT WET BULB F Temperture unit 6 Device Operation 6 1 Switching Mode During
8. tial damages including without limitation damages resulting from loss of use Some states do not allow limitations of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may have other rights which vary from state to state anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 16 AKNAHEIM SCIENTIFIC 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com 2013 Anaheim Scientific anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412
9. ure It is perfect for many industrial applications laboratory and other types of work environments Durable and reliable the M120 is easy to use 1 1 The M120 features Dual display of temperature and humidity C F modes Simultaneously hold both temperature and humidity readings Simultaneously hold both maximum and minimum and average readings MAX MIN AVG Auto power off Low battery indicator e DEW POINT and WET BULB temperature measurements anahemmscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 2 Safety Summary CAUTION A and effective usage of this meter Do not operate the meter in an environment filled with combustible gas liquids dust or fibers In order to avoid reading incorrect data please replace the battery immediately when the symbol f appears on the LCD When not using the Temperature Humidity Meter for an extended period of time remove the battery to avoid damage to the thermometer due to the leaking battery fluid Operating Environment 0 C 60 C lt 95 RH non condensing Storage Environment 10 C 60 C lt 70 RH non condensing e Cleaning and Maintenance Cigarette ashes and dust on the humidity sensor can slow down the sensor s response time while causing inaccuracy in measurements Clean up the sensor periodically by simply blowing away the dust particles Do not apply water or othe