STEAM SPA II new manual(07.3.15).cdr
Contents
1. obsessed with qually quality of life User Manual Users 1 1 The steam equipment installation location 1 The typical illustration of the steam equipment installation 2 Installation of the steam line 3 Drawing of the steam generator 5 Electrical requirements 6 Power line assembly illustration 7 Generators internal electrical wiring 8 Installation of the mood light 11 Choosing your models 12 steam generator structural drawing 13 Safety precautions of the controller 14 The safety and operating instruction of the controller 14 Control panel both SSI and SSII dimensions 15 Controller installation instructions 16 Temperature sensor installation only for SS Control Panel 17 Illustration for the controller panel SS Control Panel 18 Operation
2. power supply 10 5kW 12kW 15kW 18kW Attention to facilitate maintenance keep the steam engine clean If the information provided is limited do not touch the pipeline and electric equipment to avoid damage to the equipment do not connect strong electric current directly to the components Electrical requirements Electricity supply 1 Test the voltage of electricity supply and make sure steam generator with suitable electric voltage is used 2 Insulated copper wire should be used with an anti heat temperature of 90 C and a specified voltage of 300V Refer to national or local electricity consumption code for specifications 3 Install an independent circuit breaker between the power supply and the steam generator so to provide an electricity supply with overflow protection and electricity leakage protection A AS All the connections must in accordance with national and local electricity consumption code and be installed by professional licensed electricians A suitable metal conduit and metal conduit connector should be used for the main power wiring connections Page 6 User Manual Ampere Meter The total connected load should not be more then 80 of the rating of the overcurrent devices Tvne Electricity Applicable space of Electric YP supply the room m current A 3kW 240V 1PH 12 5A 240V PH os om 240V 1 9kW 208V GPH 240V IPH as sa 12kW 208V
3. Touching the key a second time switches the function to CD if unit so equipped This will be indicated on the screen instead of the tuner A third touch shuts the CD function off completely If no CD is installed touching the Radio key a second time will simply turn off the radio function 9 Radio Tuning Search Power on radio function selected 1 Auto search store Touch the TUN key for 2 seconds or more to turn on auto search store The tuner range is from 97 5 108 0MHZ reception location dependant This will store the strongest available signals in memory 2 Manual search store Touch the TUN key momentarily and the tuner indicator will flash Touch the Up or Down keys to tune in your desired station then touch the TUN key to store it in memory 3 To add a favourite station again use the Up or Down keys to find a favoured station Once you have touch the TUN key to store it Up to 32 stations can be stored Storage locations are named c1 c2 c3 etc on the display 4 Volume adjustment Touch the TUN key and use the Up or Down keys to adjust the volume to your preference Volume is shown on the display as a number then a d for example 25d 30d 35d etc 10 Feature Turn on the system and plug your flash drive into the provided USB slot Touch the USB key and your music will play automatically The screen will display the current music title remaining time etc Press the Up key to jump to the next trac
4. Each Exterior Wall s Insulated 1 10 for each outside wall A The calculation formula for selecting the size of steam generator is for reference only Due to the variability of the building the specifications and size illustration are used as guidelines only If we have complete information including actual blueprint project instruction and building details we can select the type of generator Page 11 User Manual Installation of the top light The rating of the light should not surpass 40W rated power to prevent damage to the transformer The light should be installed on the top of the steam room or in a place which is not accessible to children B CAUTION Take some moisture proof measures in the process of installation Do not let the electrical components be exposed to moisture or it will cause damage or short circuit The steam outlet Under Sink possible location The steam generator The illustration is just for explaination the practical installation must comply with the nation s electric criteria and performed by a professional licensed electrician Page 12 User Manual Configuration of steam generator DO NOT HEAT DURING INSTALLATION heating with torch will cause damage to plastic solenoid valve Subsidiary watertank B Fuse e Enclosure D L WARNING S Circuit board Q Main water tank D Fuse agree Q Steam Outlet Heating Element B Ground wire con
5. damp proof effect DO NOT REDUCE THE STEAM LINE PIPE DIAMETER Drainpipe 1 2 According to national or local codes the steam generator drainage valve should be equipped with a drain pipe The steam generator drains the water by using gravity AUUE The drain pipe should not incline upwards so as to prevent the drainage of water Steam generators 10 5 kw and up have an additional manual drain port right next to the auto drain port This is only used for manual draining and should remain closed at all times DO NOT HEAT AUTO FILL DRAIN VALVES WITH TORCH DURING INSTALLATION This will cause damage to the plastic solenoid valve which will cause malfuction or leakage qf G Heating with torch will cause DAMAGE Safety Pressure valve s Supplied only must be installed on site by plumber 1 Pressure valve is a safety equipment in order to prevent too much steam pressure in the steam generator due to various reasons such as steam line blockage undersized steam lines steam line traps vandalism etc 2 The Steam Safety Pressure Valve amp Switch Application 1s Mandatory A Pressure Safety Valve Steam Pressure Valve has been supplied with this steam generator unit The steam generator has removable sealed plugs in place of the pressure valve mounting location labelled A qualified licensed plumber must install the supplied pressure valve during installation of the steam generator Unscrew the plugs and screw o
6. goes out Water input steam boil Temp Time tank automatically and LED screens display Shut down the system press button again System drains out water in generator water tank automatically NOTE If power indicator LED flashes when system is activated it reports that generator water tank is lack of water System shuts down power supply to heater elements and opens water inlet valve to refill water until reaching required volume Page 18 User Manual Mood Light When system is activated press and release button to turn on the mood light Indicator LED on the right of the button should be lit Press and release button again to shut down mood light Steam ON OFF When unit is powered on press and release c button water input steam boil tank automatically press and release 65539 game button steam starts emitting Press button again to stop s steam ON OFF Steam Time Setting Use buttons to set desired steam time when system 15 activated Steam time LED screen shows set time from 5 60 minutes System shuts down power supply to heater elements automatically when desired steam time 15 over Steam Temperature Setting Use V and buttons to set desired steam temperature when system is activated Steam temperature LED screen shows set steam temperature ranging from 5C 45C or 50F 110F When ambient temperature is higherthan desired temperature syst
7. instruction S9 Control Panel 18 Illustration on the controller panel SS ll Control Panel 20 Operation instructions SS ll Control Panel 20 Maintenance of the steam generator 22 Trouble shooting 23 Specifications 24 User Manual Certified to CAN CSA Std No 88 EE DE Technical Hotline 905 951 6662 Users instruction TUBE We are not responsible for the malfunction and damage from installation that does not comply to the user manual 1 Make sure the model and the accessories correct including the voltage imput 2 Make sure the steam power are matched with the steam room dimension Pay much attention to the steam room s cubage and construction If you have any problem please refer tothe Page 11 about the dimension selection 3 Make sure to read this in manual detail 4 We shall not be responsible for the product damage or malfunction caused by self installation 5 Steamcore Spa series are packged in a box please check the goods when it arrives to assure it 1s in good conditon if you find any damage in the package please contact the transportation company to file a claim for compensation 6 This product must be used indoors THIS UNIT MUST
8. the ground Try to avoid installing near the steam nozzle or the opening side of the steam room door 2 As shown in Fig 1 drill asmall hole of 10mm inthe selected position 3 Apply acircle of silicone along the edge of the back of the sensor base as shown in Fig 2 4 Use alocknut to lock the sensor foundation As shown in Fig 2 5 Let the temperature sensor go through the back of the sensor holder As shown in Fig 3 6 The temperature sensor should be installed by extending about 1cm from the front of the room to make sure the speed and accuracy of temperature control 7 Apply silicone to the back and fix the sensor As shown in Fig 3 Temperature sensor Temp rature sensor base optional Drill Locknut for temperature sensor base 1 2 1 5m Ground Fig 1 Fig 2 Fig 3 Page 17 User Manual Illustration ofthe controller panel SS I IN OUT SHOWER USE STEAMCORE 00 00 D Power ON OFF 2 Power Indicator LED 3 Steam Temperature Adjust Key LOW 4 Steam Temperature Adjust Key HIGH 5 Steam ON OFF Control Panel 60 00 9 6 LED SCREEN D Steam Time Adjust Key LOW Steam Time Adjust Key HIGH 9 Mood Light Indicator LED 10 Mood Light ON OFF Operation instruction SS I Control Panel Power ON OFF When unit is powered on power indicator LED should be lit Press and release c button to activate system and all function buttons EI Meanwhile power indicator LED
9. the controller wire through the round hole connect it to the lengthened wire and then to the steam generator and connect with the corresponding wire in generator When the computer wire is plugged in aim the the direction and insert horizontally instead of shaking at left and right in case the computer needles could be damaged po the same when unplugging Do not pull tight or clip tight the controller wire in case of causing damage to it Step four SE Start power supply of steam engine check and 22 adjust connection check each item on the page to E make sure all functions work well oe Steam Generator SS before repairing the controller make sure the steam generator is shut off otherwise the controller may be damaged Extended wire 20ft Page 16 User Manual Step five Remove the paper on the backside To achieve good sticking effect keep the mounting surface clean and dry Step six Locate the display screen in the i Control Panel SS D Control Panel SS ID direction of 12 o clock and press tight the controller to stick it tothe wall oJ o J J J J Important To ensure horizontal uw installation of the controller use a E level if necessary zig ofo Control Panel SS D Control Panel SS ID Temperature sensor installation only for SS l Control Panel The position of the temperature sensor should be within a range of 1 2 1 5M above
10. the steam function An indicator will show this operation on the display Default temperature is set at 45deg C The timer default is set at 60 minutes An indicator will flash several times while the water is being filled In the event the water supply to the unit is interrupted the indicator will flash continuously and the steam function will shut off 4 Steam Adjustments Power on steam function selected 1 Steam Time adjustment Touch the M key to select time and use the Up or Down keys to choose your preferred time from 1 60 minutes 2 Steam temperature adjustment Touch the M key a second time to select temperature and use the Up or Down keys to choose your preferred temperature from 25deg C to 45deg C 5 Ozoner opt With the system on touch the O3 key to initialize the ozone function if unit so equipped To turn off touch the O3 key again 6 Fan opt With the system on touch the Fan key to turn it on The display will indicate fan operation 7 Light opt The Light key will operate the lights in several ways as follows With the system on touching the Light key once turns on the background light display shows L1 Touch it again and the top light also comes on display shows L2 A third touch turns them both off 8 FM CD Your IntelliSteam controller comes with a built in FM tuner Touching the Radio key once will turn on the tuner This is indicated on the main screen as a standard radio tuner
11. unions when connecting pipes to fill drain valves and steam line s 2 Use brass or copper only 3 Do not use ABS galvanized or PVC pipes DO NOT HEAT AUTO FILL DRAIN VALVES WITH TORCH DURING INSTALLATION This will cause damage to the plastic solenoid valve which will cause malfuction or leakage WARNING 11 Water supply pipe 1 2 Heating with torch will 1 Connect hot water or cold water Hot water with a temperature of not more cause DAMAGE than 160 ins 2 Install shutoff valve in the water supply pipe The shut off valve should be installed in a place where itis easily operated in emergency 3 Clean the water supply pipe completely before connecting the water pipe to the steam generator 4 It is suggested thata filter and anti furring equipment be used in the water supply pipe 5 The water pressure should be between 15 and 20 psi If necessary decrease the pressure accordingly Excess pressure may cause leakage The water flow rate should be aprox 8 gpm 6 If necessary install equipment to prevent the water hammering sound also install an approved backflow preventer as required by local codes It is suggested that a thread on braided hose with a rubber washer be used for the water supply line in order to attach the shutoff valve to the water intake solenoid Also use adequate teflon tape around the thread of the solenoids for a tight seal between the two fittings Steam Pipe Pipe Diameter 3kW 4 5kW pipe s
12. 3PH 12 15 333Ax3 The data provided above are for 240V 1PH and 208V 3PH Consult the manufacturer for three phased electricity or electric voltage of other specifications Within the steam generator install an independent circuit breaker so as to provide an electricity supply with overflow protection andelectricity leakage protection ground fault interrupter Power Supply Wire Connection Power connection terminal European Connection L2 N Neutral TINT L1 L2 L1 L2 L3 240V 1PH 208V 3PH avoid damage to the equipment do not connect strong electric current to the component directly This drawing is for explanation only For actual installation refer to national and local electricity consumption codes by professional licensed electricians Page 7 Steamcore Spa Wiring Diagram 240V 1PH Om CELL X cM UMEN Ni Li I Water Level Sensor use Red Sh Pi Bm Es Control Fam 00 Block Yellow Middle Pin OIOIO 8 Fill water valve V auto reset manual hi limit reset hi limit To Control Paral Block HIV Water Level Sensor Red Short Pin Black Long Pin Yellow Middle Pin Fill water valve V manual reset hi limit auto reset hi limit Steamcore Spa 4 5kW 240V 1PH Supply MERC CC QC QC QC QC DDR DI Water Level
13. BE COMPLETELY INSTALLED WITH UNIONS TO ALLOW EASY REMOVAL IF FUTURE SERVICE IS NEEDED It is strongly recommended that the water intake solenoid be connected to a water supply using a braided hose line Teflon tape is required to make a liquid tight seal between the threads and a rubber gasket washer is used to seal between the solenoid and the braided hose attachment Incorporate thread sealant teflon tape on both the water intake and drain solenoid for a tight seal to avoid leaks Choosing aright location A ieee Install an exhaust fan outside of the steam room so it can expel the excessive steam from the shower room Some locations recommended for installation 1 The distance to the steam room less than 20ft the standard cable which link the controller and the steam generator 22ft 2 The steam generator should not be installed in the steamroom 3 Do not install outdoors or in any places that will influence the security of the machine by the environment 4 Do notinstall a frigid loft or any place water will freeze 5 Do not install it near burnable and combustible objects or chemicals 6 Install in a dry place and make adequate ventilation NOTE Use teflon tape on the water intake solenoid and the drain solenoid to create a tight seal between the threads Absolutely do NOT apply heat to the plastic solenoids water intake amp drain during installation Page 1 User Manual 7 Stable and horizontal The steam genera
14. Sensor Red Short Pin Black Long Pin Yellow Middle Pin To Control Panal Terminal Block Sere i Yellow Green S Red J1 2_ Red Black i CD n Fill water valve V Black J2 1 Black ae 72 2 Red 31 1 Red D auto reset hi limit RE reset hi limit Black Red Steamcore Spa 6kW 7 5kW 9kW 240V 1PH Page 8 European Connection L2 N Neutral European Connection L2 N Neutral Supply IG l 1 l Water Level Sensor STATA jea short Pin To Control Panal Terminal Block Yellow Middle Pin 9 Yellow Green S Red J3 2 Red Red J2 2_ Red Black Fill water valve 7 E Black J2 1 Black a el iinet vM LL Red J1 2 Red gt 2 Black 71 1 Black 6 auto reset manual hi limit reset hi limit Black Light m Red ei Steamcore Spa 10 5kW 18kW 240V 1PH Steamcore Spa Wiring Diagram 208 3PH I l 1 I Water Level Sensor To Control Panal L3 L2 Lli iG Red Short Pin Black Long Pin Terminal Block Yellow Middle Pin OlIOlOlO Y ellow Green N N uA N N N manual reset hi limit 12 psi pressure switch UL USA Application 18kw amp Up Steamcore Spa ISkW 18kW 208V 3PH Fill water valve V auto reset hi
15. The light can not 2 The light is broken 2 Changea light bulb be turned on 3 The wire is broken 3 Change wire 4 The plug does nor have good contact 4 Make the contact good 1 Check the steam transport pipe and restore automatically after heat protection becomes cool 2 Check the heat protection wire to make sure the connection is good The display box 1 Too much pressure insidethe steam displays normally engine so thesystem breaks forheat with no steam protection input 2 Wire is broken for heat protection Technical Hotline 905 951 6662 T age 30 User Manual appr pn Consult a licensed electrician for service Technical parameter TYPE Steamcore Spa II 12V 40W 12V 40W Steam TEMP Range 50 10 50 10F 50 10F 50 10F 7 WE Lin Fin Fo Steam Pressure 0 12MPa 0 12MPa0 13MPa 0 4MPa 14MPa 0 15 0 18MPa 0 19MPa 140ml Min 160ml Min 180 220 260ml Min 400ml Min va uum e 1505 90 80 1305 90 140 240V 1PH z lt m D E Un mportant The parameter listed in the table will vary from different place and temperature please consult with qualified designer and architect for more detailed use Page 31 Steambath Generator Limited Warranty STEAMCORE Spa Il Series Steambath Generator Limited Warranty Saunacore warrants these products to be free from defects in material and workmanship and agrees to remedy any such defect T
16. e unit s built in microphone on the bottom right of the controller When a call comes in the speakers are muted and the TUN TEL indicator will flash To answer touch the TUN TEL key Touching the Up or Down keys will adjust the volume to your preference To hang up simply touch the TUN TEL key again 13 Warning System In the event of an emergency a warning key is built in to each IntelliSteam controller giving you an added measure of assurance With the system on a touch of the Warning key will cause a loud alarm to sound and turn on the lights and fan This can easily be turned off by touching the Warning key again B oB in 03 AI 4 NITE LC This set of instruction pages is to be used in combination with the Steamcore Steam Bath installation manual provided with each steam bath generator Mood Light Control e Power on off Manual colourchange B Automatic colourchange Function 1 Manual colour change 2 Auto colour change 3 30minutes by default 4 Auto colour change w o panel Instruction A Push button to activate unit system recalls all functions unfinished the last time used and presets working time to 30 minutes by default Press Button to change light colour automatically Push button to change Light colour manually Push again to deactivate system B Change colour automatically When unitis poweredon Press button light changes colour automatically as pr
17. ease intoxicated or not in good health do not usethis steam bath 2 Children must be accompanied with adults when using this steam bath 3 Steam is hot Severe burn will occur if you come in contact with the steam head or steam emitting from the steam head Maintenance of the steam generator ME perform water discharge operation after each use 1 Wait forthe completion of automatic water discharge after each time of using the steam generator to make sure the water in the tank is discharged completely before cutting off power supply 2 There should not be any leakage or damage among the steam generator steam nozzle components and pipes They should be checked and repaired annually 3 Clean the water supply pipes ofthe steam generator once a year 4 Check all the connections faucets and connection terminal to see whether they become loose or are damaged due to overheat 5 Check the furring accumulated in the water tank and electric heating tube If the furring is thick dispose itin time use diluted lemon acid to soak for 15 30 minutes 6 Remove the water level sensor needle once every 3 4 months toclean scaling Page 22 ON OFF Power Display screen Steam Light control FM CD on off USB FM Decrease Key e Warning button Remote reception IB Fan e Bluetooth b Increase Key D Ozone
18. em shuts down powersupply to heater elements automatically Meanwhile temperature readings on LED screen flash until ambient temperature gets lower than set temperature Do NOT set temperature setting more than 110F 45C Select Temperature Unit INA When system has been turned off press V ana P buttons at the same time LED screen shows current temperature unit Page 19 User Manual Illustration of the controller panel SSII amp SQID Control Panel INSHOWER USE ONLY Q Power switch Timeset button 9 Time temperature decrease button 4 Time temperature increase button Light function button 6 Temperature setbutton C2 Digital display screen S Steamcore 9 The front decorative panel Temperature sensor Operation instruction SSI amp SQI Control Panel The controller is digital temperature control system which can start stop or pause in the preset time to keep the temperature in the set number ON OFF When it is electrified the system shuts off all the loads to remain in a waiting state and the digital tube will display as is shown in Fig 1 In the waiting state press button Oto turn on the system and the steam function The default time of starting the steam is 30 minutes and it begins to count down and the default temperature of the steam is 110F After the system is started the digital tube will display the current temperature of the environm
19. ent and the temperature check range is 50 110F Page 20 User Manual When he actual temperatureis smaller han orequal to32F the digital tube will display 32F When the actual temperature is smaller than or equal the digital tube will display 110F The last digit displays as the unit of Fahrenheit temperature The default start time of steam function 1s 30 minutes When the steam is starting thereis ashortage of water the heating wire will stop heating and the water input valve will start automatically Ifthere is no watertested in 5 seconds or no water coming to reach the full volume in 15 seconds the digital tube will flash to display F as shown in Fig 3 to hint mistake If the water is full the steam function will return to normal When the steam function is started if the temperature of the environment is higher than the set steam temperature the heating wire will stop heating the digital tube will flash to display the current environment temperature when the environment temperature is lower than the set steam temperature the heating wire will restore heating the digital tube willdisplay normally current environmenttemperature When the system is started press button or when the steam function time 1s due the system will be shut 10 minutes after the system is shut off the drainage function will be started automatically for5 minutes Time setting When the machine 1s started press butt
20. eprogrammed and each colour remains for 5seconds Push button again lamp keeps present colour push button forthe third time lamp goes backto changing colour automatically C Change colour manually Each time button is pressed light changes one colour in the following order White red purple blue yellow green orange C E Mood Light Control Technical Date Working Condition Voltage inlet AC 230V Rated Frequency 50HZ Voltage outlet DC12V Rated current 300mA Others Max inputvoltage DC oflamp max DCI18V Remark 1 Input voltage is associated with the supplied transformer It canbe 110V inlet volts 2 Unit would be damaged if the input voltage exceed the Max limit Page 29 User Manual Common trouble shooting methods To facilitate your use and maintenance of sauna room the following common trouble shooting methods are listed for reference Causes of troubles Trouble shooting methods 1 Change the fuse on the shell 0 8A The machine 2 The wire connection terminal 250V does not start becomes loose when 3 Not good contact in the electrified connection wire between the controller and the steam engine 2 Plug tight the wire connection terminal 3 Make sure the steam engine and the controller come into good contact Electricity 1 The wi is d d Check whether the wire connector 15 leakage switch i dampened or da
21. haser agrees to pay all labor costs fees incurred in connection with such repair Warranty work will be performed when the steam generator is returned to a designated Saunacore location with a RMS number WARRANTY does not cover damages caused by Calcium Lime Stone build up or corrosion to the components to the steam generator Warranty Registration Card Model Serial Purchase Date Dealer Name and Adress Owner Name and Address NOTE A COPY OF THE RECEIPT MUST ACCOMPANY THIS WARRANTY CARD
22. his warranty does not apply outside the boundaries of the United States Canada or any product which in our sole opinion has been improperly installed or subject to willful abuse misuse alteration and shipping damages during the period of coverage Postage and handling charges of the product to and from Saunacore for warranty repairs and for any related charges for the installation removal of these products are NOT included in your warranty Warranty service can be obtained by sending your product to Saunacore Call 905 951 6662 Warranty repairs must be done only by Saunacore Proof of purchase and a serial number of the product will be required before any services are performed Warranty applies only to the original consumer purchaser warranty is non transferable For warranty repair the steam generator must be returned to Saunacore with an Return materials Authorization and is to be obtained by the original consumer purchaser and must be shown on all correspondence and packing without this RMA returns for repairs will NOT be accepted Controls amp Cables One Year Parts and Labor Steam Generator Only One Year Parts and Labor Second Year to Fifth Year Warranty Claim Fee Admin Deductible Fee Applies 150 00 Steam Generator Components Continuing after First Five Years of original consumer purchase date Components Only Coverage Components Warranty excluding auto drain control and cables provided the original consumer purc
23. ize 1 2 6kW amp above 3 4 1 Do notinstall any valves inthe steam pipes The steam can nevet be obstructed 2 Install one or more steam lines equal to your steam generator steam outlet s and with the same same diameter size copper steam pipe between the steam outlet and the steam nozzle 3 The heat insulation material used to insulate the steam pipe should be resistant to temperature as high as 250 Ff or higher 4 The horizontal part of the steam pipe should be installed inclining to the steam outlet or in the direction of steam generator Do not bend it in a shape to make the cooled water stay in the curved pipe of the steam line 5 The shorter the steam pipe the better Try to decrease the number of elbows and avoid abrupt turns Do Not combine steam lines if generator has more than one steam outlet Steam nozzle 3kW 4 5kW pipe size 1 2 6kW amp above 3 4 STEAM LINE Ta Attention Do not install the steam pipe in an upper or lower direction repeatedly this will affect the output of steam Make sure for each steam outlet on the generator there is an individual steam pipe to the steam room with the same diameter size as the outlet N RUE Since the steam nozzle and steam outlet are very hot try to avoid installing dM he steam nozzle in the position which will easily come into contact with a person Install steam heads away from bathers path or from any direct contact Add appropriate protection to avoid bodily harm or bu
24. k s or the Down key for the previous track s Touch the TUN TEL key to pause playing and touch it again to resume Touch the USB key again to turn it off 11 Bluetooth 1 First turn on your smart phone s Bluetooth function and search for new devices normally there is one Bluetooth device to be found This should be done in close proximity to your IntelliSteam controller 2 With the system on touch the Bluetooth key The indicator will flash and a bt will be indicated on the display 3 Select the device Bluetooth on your phone and the pair should connect automatically Once this occurs the indicator will remain lit confirming a successful connection Some smartphones may require entering a password during the pairing connection process Use the default 0000 password for this After connecting touch the Bluetooth Now you can use Bluetooth to play music or answer a call Touching the Up key skips to the next song and touching the Down key skips back to the previous one Touch TUN TEL to pause playing and again to resume play When you receive an incoming phone call touch TUN TEL to answer and again to hang up Touching the Bluetooth key again will turn off the Bluetooth function 4 Each time the control panel is turned on it will search for the last connected Bluetooth device and attempt to reconnect to it automatically 12 Telephone Incoming calls only This function if line is installed utilizes th
25. limit lack Supply a ns een ens n i Water Level Sensor Ey i Panal LTTE Red Short Pin 5 o Contro Fana ig Terminal Block 1 Yellow Middle Pin B Le Yellow Greenl Red 72 1 Red Fill water valve V auto reset manual li hi limit s Light X Brown 9kW 208V 3PH Supply Water Level Sensor DOR To Control Panal e Block Yellow Middle Pin 018199 Vellow Green Red ji 1 Red Red 2 1 Red NE Red 172 2 Red Red 71 2 Red ul Red J3 1 Red Black Ems Red 73 2 Red Fill water valve L M reset Em i limit C manual reset 2 V hi limit Red Steamcore Spa 10 5kW 12kW 13 5kW 208V 3PH Page 10 European Connection L2 N Neutral User Manual Sizing steam generator Measure the length width and height feet of the current steam shower or bathtub area that has a ceramic wall finish Example L 7xW 5xH 8 280 Cubic Feet x 25 for Ceramic Wall Finish 61 25 61 25 280 341 Total You would need a 9000 watt 9K W steam generator However if your shower materials are is multiplied by Acrylic cultured marble 0 08 Ceramic Tile on Cement Board 1 30 Ceramic Tile on Mortar Bed 1 30 Glass or Glass Block 1 35 Porcelain tile on cement board 1 60 NATURAL STONE TILE marble granite slate travertine etc On Cement Board 1 90 On Mortar Bed 2 00 Natural Stone Slabs over 1 2 thick 225
26. maged and dry with breaks iir WE dryer if dampened automatically 2 The heating tube breaks 2 Change a heating tube When the machineis started hot water comes out with little or no steam 1 The water drainage valve isbroken 1 Change awater drainage valve I The power wireis not connected well The display screen or notin good contact The connection on the controlpanel Plug between the control panel and the does not display electrically controlled box becomes loose 2 Trouble with plugboard 1 Check whether the connection plug between the control panel and the electrically controlled box has become loose and whether the powercircuitry has goodcontact 2 Change a plugboard I The water pipeconnector becomes 1 Tighten the loose connector and change the loose or the pipe breaks broken pipe 2 Water leakage inthe water input 2 Change the waterinput valve orthe water valve or the waterdrainage valve drainage valve Water leakage lecti 1 Check the power supply No steam when 1 No electricity 2 Check the water input pipe and water input starting the 2 No water valve machine 3 The set temperature is too low 3 Reset the temperature 4 Troublewithwire 4 Contact the distributor The steam does not come out the water sounds inthe machine 1 Cut power supply to check whether the 1 Thest ipe is j d ipei vore steam pipeis smooth 1 The fuse is burned 1 Change the fuse on the shell 1A 250V
27. n the pressure relief safety valve supplied Make sure hi heat silicone is used to seal the safety valves to the boiler tank when attaching allow silicone to cure 24 hours The Pressure safety relief valve must be installed by a qualified licensed experienced plumber Steam Generators 18 KW 18000 watts and higher will have a factory installed Steam Pressure Switch This switch will cut power to the steam generator when the inside of the boiler tank or steam line s pressure reaches over the manufacture s recommended limit The switch will reset and activate power when the excessive pressure has been substantially reduced This will re occure until the cause of excessive pressure has been rectified Page 4 User Manual Steam generator blue print Steam outlet WI Safety valve gt L 230mm Waterinlet WA 160mm Water _ drainage Controller wire and light wirehole Power wire hole metal conduit connector required Fuse for wire power supply 3kW 4 Water drainage Controller wire Power wire hole and light wirehole metal conduit connector required Fuse for wire power supply 6kW 7 5kW 9kW Page 5 User Manual Steam outlet E 5 Water inlet gt mW CN Water drainage Controller wire Power wire hole e o light wirehole metal conduit connector required Fuse for wire
28. nector Pressure Safety Valve D Heat Hi limit Relay Water fill valve Transformer Water level sensor Water drain valve B Terminal block D Manual Reset Hi Limit Mood light transformer Use teflon tape and rubber gasket washer when attaching fittings to the water fill and drain valve to create a liquid tight seal Page 13 User Manual Controller Maintenance 1 Use soft cloth witha little soap water to clean the controller 2 Do notuse harshcleaning tools 3 If the controlleris damaged call a service electrician to replace it Safety and operation information of the controller If the installation and operation instruction is not read or understood do not install In case there should be any dangerous installation and improper operation Install the controller based on the installation instruction otherwise the temperature in the steam room will be too high or not heated enough If the controller is installed outside the steam room the temperature sensor must be installed in the steam room Do not install the controller wire in the same conduit with high voltage electric wire Do not install close to hot water or steam pipe ETIE Before installing the controller make sure the steam generator power is off otherwise the controller may be damaged The instruction includes important safety operation and maintenance information Keep the instruction in the user s hands If the steam generator is damaged
29. on and the digital tube will display the remaining time of current steam function as shown in Fig 4 press button or V button to adjust the remaining time The adjustmentrange is 5 60 minutes with minute as one level If there is no adjustment in 5 seconds the system will quit the time setting function The digital tube will restore to display current environment temperature Temperature setting Whenthemachine is started press button and the digital tube will display the set steam time as shown in Fig 5 at the same time the temperature unit will flash to hint that the machine has entered the steam temperature setting function At this time press button or V button to adjust the temperature parameter The adjustment range is 50 10 T with 1 Fas one level If there is no adjustment in 5 seconds the system will quit the temperature setting function The digital tube will restore to display current environment temperature Do NOT set temperature setting more than 110F 45C Page 21 User Manual Light function When the machine is started press button repeatedly to turn on off light function When the light is turned on the digital tube will temporarily display LON asis shown in Fig 6 When the light 19 turned off the digital tube will temporarily display LUFF asis shown in Fig 7 E I Please consult your physician before using If you are pregnant elderly have high blood pressure diabetes suffering from heart dis
30. or does not work normally do not continue to install or use the controller Turn main power supply off Page 14 User Manual Control panel both SSI and SSII dimension SSI and SSII Control panel may beswitched for Spa II 160mm 70mm 23mm STEAMCORE Temp Time Oi ON OFF 113mm Page 15 User Manual Installation instruction of controller Important Before installing the controller make sure the steam generator is shut off otherwise the controller may be damaged Step one Determine the installation location of the controller The controller is designed to be installed in the steam room 1 4 5 feet from the ground 2 Away from the steam nozzle and do not expose under the direct path of steam 3 Installation on perpendicular wall 4 The position of installation should facilitate easy operation and convenient wiring The controller wire is 1 0 feet long with a controller lengthened wire of 20 feet long at the most In the installation of controller it should be in a position not more than 21 feet from the steam engine If longer wire is needed contact professional service personnel eal OTT Do not install the controller under the water pipe or in a position where water comes into contact Control Panel SS D Step two Drill a round hole of 7 35mm in diameter in a chosen S 2003 position no larger or smaller Step three Pull
31. r D e MIC Congratulations on your new Saunacore steam unit with the advanced IntelliSteam controller This booklet will help you get the most enjoyment out of your device s many capabilities and features NOTE 1 All controller keys are touch sensitive and do not require physical pressure NOTE 2 The power button located on the upper front of the unit performs several different functions depending if it s touched momentarily or held for several seconds It also is an LED indicator which glows RED System in standby mode GREEN Display indicator flashing Keypad is locked keys are disabled GREEN Display indicator is steady Keypad is unlocked commands can be entered WHITE System on radio CD function in use 1 Power On Off When the system is in standby mode Indicator is Red touch the Power Key for 3 seconds or more The display will light up and glow green Momentarily touching the Power Key returns the unit to standby The unit will enter auto shutdown in 1 hour if no buttons are touched during that time 2 Unlocking the controller If no function keys are touched for 20 seconds the system will auto lock the keypad and the Dotted line Solid line indicator on the display screen will flash Touching the Power Key for 3 seconds will unlock the system making all keys active 3 Using the Steam Function With the system on touch the Steam key to initiate steam generation The radio must be off to initiate
32. rns 1 Install the steam nozzle in the position 12 inches above the ground If the steam bath is in the bathtub install the steam nozzle 6 inches above the bathtub If the steam room materials like acrylic or non heat resistant sheet install additional heat insulators 2 The steam outlet should be installed face down Install the steam nozzle and tighten AN with hands use silicone Attention In order to protect the steamnozzle do not use wrench or other tools to tighten use a little soap water and soft sponge to wipe and do not use corrisve chemical solutions or harsh cleaning tools Page 3 User Manual I Please consult your distributors of building materials like acrylic fiber glass or other anti heat sheet about the installation position of steam nozzle Itis suggested that MS 103412 anti heat material can be used 2 In the entire steam room it is required that steam must not leak out The pipes its accessories and the holes in the wall should be airproof by applying silicone so that no steam will enter the holes in the wall Aroma Essence Reservoir apply a few drops If non heat resistant material like acrylics 15 used as building material reserve a gap no less than 1 4 and fill with silcone i l J pc Use silicone to fill in the xx gaps in the wall to Inside wall ot the steam room achieve the water proof and 4
33. tor has a hanging groove for mounting on the wall Make sure the machine 15 steady and horizontally installed 8 On both sides and the top of the steam generator needs atleast 12 inches of clearance space 9 The place where the machine is installed must be easily accesible and convenient for the disassembly of the machine 10 The installation place mustbe convinent for the drain ofwater 11 The steam pipe safety valve drain valve water tube steam outlet are still very hot after the steam generator has stopped working for some time Keep the steam outlet away from the people Bodily injury or burn may occur provide appropriate protection 12 The controller must be installed in the steam room please refer to the instruction of the controller s installation and operation of the manual Mi ttention The steam generator including the controller comply with CE CSA and UL certification standards Installation drawing of the steam generator BIS tention The drawing isonly for sample As for practical design of steam room please consult with qualified designer architect or builder p Suppl T Control Cable 4 20ft max 7 CAL Steam Outlet 7 mw C WARNING Heating with torch will cause DAMAGE Fill amp Drain Solenoid Valves Page 2 User Manual Installation of pipeline The installation of all the pipes should be done by a qualified Warning licensed plumber 1 Use threaded
Download Pdf Manuals
Related Search
Related Contents
Elta ST104N User's Manual MODE D`EMPLOI mc-22 - MHM trombinoscope 12-11-2014 American Standard 14CL.331900.073 Installation Guide HH-LE271L(取扱説明書) (2.96 MB/PDF) AirWorks AWK-3121-RTG User`s Manual 7月3日産業商工会館にて、 「外国人ごみ会議」が開催されました。 1734-SG001E-EN-P POINT I/O Modules Selection Guide 3-Heights™ PDF Security Shell, User Manual Copyright © All rights reserved.