Home

Instructions

image

Contents

1. A Approximately 5 32 or less gap will be present between the lt 1 Tighten D Dit Thumb Screws 1 N Housing Front and bottom of Port when the Dome or Flat Port is properly installed x 7 Removing the Dome Port continued Diagram B Thumb Screw I L eooo Port Base O ring should be lightly lubricated use Ikelite lubricant only ay INU Installing the Flat Port 1 First check to see that there is a thin film of lubricant on the Port Base O ring The o ring should appear slick If necessary relubricate with the supplied Ikelite lubricant Do not use excessive lubricant which can attract hair or other debris Use ONLY Ikelite lubricant Make sure the o ring is free of hair or other debris Lift and REMOVE the gear sleeve from inside the Port Base Place the Gear Sleeve in storage for later use with the Dome Port Slide the Flat Port over the Port Base until it STOPS Diagram C Page 5 When properly installed there should only be an approximate 5 32 or less gap between the bottom of the Port and the front of the housing Diagram A Page 2 Snugly tighten the 3 thumb screws into the Port Base DO NOT overtighten No Thumb Screw threads will be visible once the Port is properly secured The gear sleeve must be re
2. ikelite 5516 50 MIL Flat Macro Port Extended Instruction Manual Thank you for your purchase of Ikelite equipment Please read this instruction manual completely before attempting to operate or dive with this product Please refer to the back page of this manual to register your Ikelite product The 5516 50 MIL Flat Macro Port Extended features a delrin body and glass front This large diameter extended length flat port is designed for use with larger macro lenses such as the Canon EF S 60mm Macro Lens Go to www ikelite com for other compatible macro lenses A 67mm threaded front allows for the attachment of external wet lenses What s in the Box Flat Port Neoprene Cover Spare Thumb Screws Spare o ring Silicone Lubricant 1cc Tube Removing an attached Dome Port No tools are needed to remove an existing Dome Port and attach the optional Flat Port to your housing Diagram A 1 Three Thumb Screws secure the Port on the Base Turn each Thumb Screw counterclockwise so at least 3 to 4 threads are showing 2 Gently lift the Dome Port off the Port Base Diagram B Page 3 If the Port seems stuck loosen the Thumb Screws another turn or two until the Port can be removed 3 REMOVE the gear sleeve Caution A DO NOT leave the Port off the Port Base for extended periods of time This can result in debris being attracted to the Port Base O ring Diagram B Page 3 resulting in a bad seal Diagram
3. ior authorization is required You may return directly to us or through your dealer Please include a brief description of the problem any relevant email correspondence and or instructions on what you want us to do Always include name shipping address email address and phone number inside of the package Send postage paid to Ikelite Underwater Systems Attention Service Department 50 West 33 Street Indianapolis IN 46208 USA No reimbursements for postage paid will be issued You may also want to insure the package Returning Products for Service outside the United States For the separate international customs documentation form that you complete to accompany the shipment please state or designate that the enclosed products were originally manufactured in the USA and are being returned to the manufacturer for repair service Value of the equipment listed for customs purposes should be zero Product Registration Please go to www ikelite com to register your Ikelite housing within 15 days of purchase Ikelite Underwater Systems 50 West 33rd Street Indianapolis IN 46208 USA www ikelite com 2014 Ikelite Underwater Systems 5516 50_MIL_Flat_Macro_Port_01 1214
4. moved BEFORE using the Flat Port We recommend placing the closed housing in a pool or bathtub to assure proper installation and watertightness before installing your camera Installing the Flat Port continued Diagram C _ Loosen Tighten gt i Thumb Screw Port Base O ring should be lightly lubricated use Ikelite lubricant only M Alt Spare Parts Can be ordered through any Ikelite dealer or by calling Ikelite customer service 0184 2 Silicone lubricant 2cc resealable tube 0203 89 Thumb Screw Customer Support Ikelite Underwater Systems Service Department 50 West 33rd St Indianapolis IN 46208 USA Email ikelite ikelite com Phone 317 923 4523 Limited Warranty This Ikelite product is warranted against any manufacturing defects for a period of one 1 year from the original date of purchase Defective products should be returned to Ikelite postage paid Ikelite will at its sole discretion repair or replace such products and will return to customer postage paid All other claims of any nature are not covered Except as mentioned above no other warranty expressed or implied applies to this Ikelite product Returning Products For Service Ikelite is most interested in performing any service to ensure that all products perform as intended Evidence of purchase date must be provided to obtain warranty service No pr

Download Pdf Manuals

image

Related Search

Instructions instructions synonym instructions not included movie instructions for 1040 2024 instructions for form 8962 instructions brp instructions meaning instructions in spanish translation instructions for 1040 instructions unclear meme instructions for schedule c instructions for form ss-4 instructions for form 941 instructions for form 720 instructions for 1040 2023 instructions for form 8949 instructions for box 12 on w2 instructions for form 1040 instructions for submitting certain i-589 instructions synonyme instructions to candidates

Related Contents

HP Webcache Filter Series User's Manual  Quantum Travan 20 SCSI User's Manual  Quick Guide for TELE - TELE INFO 2.2  VAS 6307  Ufuidotnet IME用郵便番号辞書取扱説明書    Panel de control de intrusión Easy Series  Toshiba Satellite L655D-S5159BN  Manuel d'utilisateur  World Imports WI930237 Installation Guide  

Copyright © All rights reserved.
Failed to retrieve file