Home

USER MANUAL - LifeTec Inc.

image

Contents

1. pm omm Huntleigh A K RON AKRON BOBATH 5 Model 4632 USER MANUAL AKRON 4632 Contents 1 10 Introduction Warnings Cautions General Warnings Installation Operation Optional Accessories Operating Instructions Cleaning and Decontamination Troubleshooting Maintenance Warranty and Service Revision Status Technical Specification Ce The CE mark on this product demonstrates conformity with the EC Directive 93 42 EEC NO 10 AKRON 4632 1 Introduction Always keep this Operating Manual available for reference Warnings amp Cautions WARNINGS Warnings identify possible hazards in procedures or conditions which if not correctly followed could result in death injury or other serious adverse reactions CAUTIONS Cautions identify conditions or procedures which if not correctly followed could result in equipment failure or damage General Warnings WARNINGS Use only accessories that have been designed or approved for use with this table Do not use electric tables in the presence of flammable gasses such as an anaesthetic agent Maximum Load 325 Kg 715 lbs distributed evenly Do not concentrate weight on either side of the table Plug acts as a disconnect device Do not allow children to play with the table at any time Adequately supervise children in the proximity of the table AKRON 4632 2 Installation WARNING Do not insert the 2 pin mains co
2. l cord away from moving parts prior to repositioning table Wheels Wheels Locked Directional Lock Wheels Unlocked AKRON 4632 4 Optional Accessories Operating Instructions CAUTION Ensure accessories are secure prior to use Fold Down Safety Sides a To raise the safety side when in the down position lift and rotate towards you through 180 Once upright push the safety side downwards into the moulded block until located fully su b To lower the safety side from the upright position lift out of the m mr cd moulded block and rotate through 180 into the down position SA 2 Patient Assist Support Handles a To insert support handles position pin into socket b Secure by tightening locking knob C To remove support handles loosen locking knob and lift support handles out of the socket a To insert arm loop position pin into socket b Secure by tightening locking knob C To remove arm loop loosen locking knob and lift arm loop out of the socket Remove plug for patient prone position Press out from underneath AKRON 4632 5 Cleaning and Decontamination WARNING Do not use Alkalis or other organic solvents for routine cleaning Replace torn or damaged vinyl immediately Always cover vinyl with fresh paper or sheet between patients If contamination is known or suspected always decontaminate table before use Frequency of routine table cleaning will depend on e
3. nnector directly into a 3 pin 13A mains outlet Always use the adapter provided Plug acts as a disconnect device Use adapter if 3 pin 13A plug is required Order reference 5804097 Ensure mains supply cable 15 not stretched when connected Ensure during table use no obstacles are in its path Ensure hand foot switch tubes or leads are not trapped by moving parts of the table CAUTION When not in use switch table off Battery Backup CAUTION Battery Backup 1s for the unlikely event of mains power failure not normal use The table should always be used with mains power connected The light on the control box indicates mains power is on Whilst on batteries are trickle charged in case of power failure To charge the accumulators the control unit must be activated by shortly pressing one of the switch keys AKRON 4632 3 Operation Elevation Controls WARNING Safely position patient before elevating table Position all electrical cables away from the moving parts Position Hand Foot switch where accidental operation is not possible Press up to raise table Press down to lower table Press up to raise backrest GH Press down to lower backrest Handswitch Backrest Angles 85 0 Wheel Locking WARNING Lock table wheels castors prior to patient transfer or treatment The retractable castors are not designed for transportation of patients Disconnect and coil electrica
4. rom the electrical supply Plug acts as disconnect device Examine the table for any signs of damage Make sure that all nuts bolts and other fasteners are tight Do not over tighten as this may cause binding Upholstery fasteners should be checked tightened or replaced 11 necessary Check section hinge pins to ensure that no pin protrudes Check gas strut controls throughout the full range of movement for locking and assistance Check hydraulic tables for smooth operation and signs of leakage WARNING All electrical checks should be performed by a suitably qualified and licensed electrician Neither BLUE or BROWN wires are to be connected to the earth terminal of a three pin plug Examine the flexible cables for cuts abrasions kinking or other deterioration and replace if necessary Ensure that the power supply connector plug 15 securely attached Check mains plug connections are tight and fuse is correctly rated SA AKRON 4632 8 Warranty and Service UK only Huntleigh Akron s standard terms and conditions apply to this couch A copy 15 available upon request These contain full details of warranty terms and do not limit the statutory rights of the consumer For service or maintenance please contact Service Department Huntleigh Healthcare 310 312 Dallow Road Luton Beds Telephone 01582 745700 LUI ITD Fax 01582 745869 For information on this product or any other Huntleigh Akron product please contac
5. t Huntleigh Akron 1 Farthing Road Ipswich Telephone 01473 461042 IP SAP Fax 01473 462924 Huntleigh Akron T A a Division of Huntleigh Nesbit Evans Limited A Member of the Huntleigh Technology PLC Group of Companies O Huntleigh Technology PLC 2002 If for any reason your couch 15 being returned please inform Huntleigh Akron prior to sending and 1 Clean the product as described in the cleaning section Pack it in suitable packing gt Attach the decontamination certificate or other written statement declaring that the product has been cleaned to the outside of the package 4 Mark the package Service Department Manufactured in the UK by Huntleigh Akron As part of the ongoing development programme this company reserves the right to modify specifications and materials of this couch without notice AKRON 4632 8 Warranty and Service UK only Huntleigh Akron s standard terms and conditions apply to this couch A copy 15 available upon request These contain full details of warranty terms and do not limit the statutory rights of the consumer For service maintenance and any questions regarding this or any other Huntleigh Akron Product please contact Huntleigh Akron 1 Farthing Road Ipswich Suffolk IP1 SAP England Telephone 44 0 1473 461042 Fax 44 0 1473 462924 Huntleigh Akron T A a Division of Huntleigh Nesbit Evans Limited A Member of the Huntleigh Technology PLC Group of Companies O H
6. untleigh Technology PLC 2002 If for any reason your couch 15 being returned please inform Huntleigh Akron prior to sending and 3 4 Clean the product as described in the cleaning section Pack 1t in suitable packing Attach the decontamination certificate or other written statement declaring that the product has been cleaned to the outside of the package Mark the package Service Department Manufactured in the UK by Huntleigh Akron As part of the ongoing development programme this company reserves the right to modify specifications and materials of this couch without notice 9 Revision Status 4632 PAGES ISSUE WRITTEN DATE ALL PAGES UM 01 28 06 02 AKRON 4632 10 Technical Specification 4632 p Head Length cm Foot Length cm Width cm Overall Length cm Height Range cm 501 5 971 5 Max Load Weight 325 Kg Elevation Control Electrical Data 230v Voltage 220 240v 50Hz Current Power 24v 6A Electrical Data 115v 115v 60Hz 24v 6A IEC 601 1 Classification Class 1 Type B equipment Attention consult this manual 10 AKRON 4632 11 AKRON 4632 12 pm 5 Huntleigh A KRON Huntleigh Akron 1 Farthing Road Ipswich Suffolk IP1 SAP England Tel 44 0 1473 461042 Fax 44 0 1473 462924 792 462 01
7. xact application CLEANING DECONTAMINATION Wear suitable protective clothing Disconnect mains supply Locate couch in a suitable cleaning area with castors disengaged or wheels locked A Using a clean damp cloth warm water and soap carefully wipe table from top to bottom taking care around electrical components B Wipe table carefully from top to bottom using a damp cloth and clean water C Wipe table carefully dry with clean paper towels from top to bottom If DECONTAMINATING then repeat steps a to c using a dilute Hypochlorite warm water mixture 10 000ppm instead of warm water and soap Safely discard cleaning decontaminating materials Wash hands thoroughly Put table back into service 6 Troubleshooting Electric Actuator Symptom Actuator will not work Power disconnected Ensure mains supply is connected Fuse blown Replace fuse in socket Hand footswitch Check that the hand foot switch 15 fully disconnected inserted into the actuator Thermal protection Disconnect power cord from mains supply Leave unit for 1 minute then re connect power cord If the problem persists consult your local Akron Supplier AKRON 4632 7 Maintenance Check table visually before use Carry out routine servicing every six months or more frequently 1f in heavy use Routine servicing or repair must only be performed by suitably qualified person WARNING Before commencing any maintenance activity disconnect the table f