Home

Pressure Relief Valve

image

Contents

1. a 0 750 ICH 0 725 z ZA 04 Specifications MECHANICAL Material 6AL 4V titanium Diameter 1 85 cm 0 725 in Length 1 91 cm 0 75 in Weight in Air 11 7 g 0 42 oz Threads 7 16 20 with O ring face seal ENVIRONMENTAL Depth 20 000 psi full ocean depth Temperature 20 deg C to 200 deg C 4 deg F to 392 deg F Pressure Relief Valve 07 02 04 PRV Cracking Pressure Adjustment 1 Using a small spanner wrench gently turn PRV adjusting valve clockwise to full stop 2 Refer to Cracking Pressure Chart to correlate number of adjustment valve turns to desired setting listed in PSI Refer to chart curve 1 for in air settings and curve 2 for in water settings 3 Slowly turn adjustment valve clockwise to desired setting CRACKING PRESSURE CHART Setable 2 psi to 15 psi or closed TURNS Curve 2 Curve 1 Chart shows pressure for turns away from closed position and indicates the increase in setting from testing in Air curve 1 to testing in Water curve 2 Pressure Relief Valve 07 02 04 Installation 1 Drill and tap 7 16 20 hole into housing insuring that there is a minimum s of an inch thread depth Insure that o ring sealing surface is smooth and clean Requires o ring seating surface finish of 32 or better Grease O ring using DC 111 or DC 4 silicone lubricant Only a t
2. If notice of defect is given to DeepSea Power amp Light Inc within such 90 day or one year warranty period the sole obligation of DeepSea Power amp Light Inc shall be to furnish new or repaired parts free of charge in exchange for parts which have been proved defective and does not include any other costs such as the cost of removal of the defective part installation labor or consequential damages of any kind the exclusive remedy being to require DeepSea Power amp Light Inc to furnish such new parts Under no circumstances shall the Buyer be entitled to recover any incidental damages as that term is defined in Commercial Code 2715
3. 30 00 or 15 minimum handling charge whichever is greater Items must have shipped from DeepSea Power amp Light Inc no more than 30 days prior to requesting an RMA Return freight charges shall be paid for by Customer Non standard or used parts are not returnable C Any return repair or replacement shall be subject to DeepSea Power amp Light Inc Quality Assurance acceptability D Buyer assumes all risk of damage or loss or destruction of the property which is accepted for return repair or replacement as provided above It is expressly agreed that all risks of loss are borne by Buyer from and after the time of shipment from Seller to Buyer Pressure Relief Valve 07 02 04 Notice The technical drawings and data published in our manual bulletins or literature is not guaranteed It is considered sufficient technical data to allow proper identification of equipment type size and use for ordering purposes All drawings and measurements are approximate and not to scale Performance and function for which the product is intended will depend upon lighting conditions visibility cable size and termination Technical data is subject to change without notice Detailed engineering information is available upon request DeepSea Power amp Light Inc assumes no responsibility for proper selection or installation of its products Fair Labor Practices We hereby certify that products and services are produced in compliance with all applicable requi
4. Flow Data Comparision of Rev B and Rev C Pressure Relief Valves PRV Rev C flow rates valid for units shipped after 7 1 02 Flow Rate SCFM e 701 00001rev C Flow Rate SCFM m rev B Flow Rate N 0 20 40 60 80 100 Pressure psi 120 Pressure Relief Valve 07 02 04 6 Terms and Conditions of Sale No terms or conditions other than those stated herein whether contained in customer s purchase order or shipping forms or elsewhere and no agreement or understanding oral or written in any way purporting to modify or negate these terms and conditions shall be binding on DeepSea Power amp Light Inc Acceptance of Orders A Acceptance of binding purchase orders is subject to final written approval by DeepSea Power amp Light Inc B DeepSea Power amp Light Inc will accept orders and bill in accordance with list prices and terms even though incorrect list prices discounts and terms may appear on the Purchase Order Terms Kam approved credit the following terms will apply A Standard terms are net cash 30 days from date of invoice unless otherwise specified Invoices bear the date of shipment and are mailed from San Diego CA within one business day of the shipment B Any portion of the Invoice amount which has not been paid within 30 days of the invoice date will accrue a monthly service charge equal to the maximum rate permitted under Section 1 Article XV of the Califo
5. Pressure Relief Valve User Manual 701 00006 DH D HILD OUD SeaTeth China Co Ltd Td 486 20 4891309 34891311 Fax 86 20 34799515 web www sestechchina com Enal seteh l26am Pressure Relief Valve User Manual 7 02 04 Table of Contents Section Page Lee oise sedes wes ee De DE Ao ie Ge Ge Ee Ge de ee WA GE di de GE Ee de 2 Specifications ss ES giles SG KG Re aa 2 PRV Cracking Pressure Adjustment s sssss0 3 MNA EO EO OE EE ER EE 4 Important NOUE iss Ee Gee MEE ee Gee ee Se Ge Ge De We GR GN Or ke ie waza de 4 Vaccum Purge Port Instructions icsscicssisseesssesseccansatessasdvesnatsbecsbasdievesashaducsdavacdocuseacensusteuseoesiancend 4 Pressure lg teen ege eege nce tened isese ter veut se N EE OR susan 5 Terms and Conditions of Sale ccccccccsccccccccccceccces sesssssssssssccecscccccccsssccccccccesess 6 Pressure Relief Valve 07 02 04 Introduction Congratulations on your purchase of the DeepSea Power amp Light Pressure Relief Valve DeepSea s universal pressure relief valve can be used on instrument housings battery packs and other applications requiring venting Made from titanium and measuring only 1 85cm 0 725 in diameter by 1 91cm 0 75 in overall length this valve is rated to full ocean depth The valve s release pressure can be easily adjusted and can also serve as a vacuum purge port A dry spring design is used all wet parts are titanium
6. hin film of lubricant is necessary Apply a small amount of locktite 242 on threads of pressure relief valve caution do not allow any to drip onto o ring Use installation tool 701 00020 02 or small 3 32 spanner wrench to screw pressure relief valve into housing Use hand torque not to exceed 100 inch pounds Important Notes If the venting of internal pressure includes debris silica gel particles metal shavings battery chemicals etc the PRV may fail Failure may take two forms 1 Debris may pile up inside the PRV and clog it resulting in over pressuring the volume to be protected 2 Debris may prevent resealing when relief flow ceases If the equipment produce debris it is critical that screens or filters of sufficient area are provided to handle the volume of debris produced Vacuum Purge Port Instructions 1 Loosen the valve stem so it is only at 1 psi or less Count turns so you can reset it later to the desired cracking pressure Snap on the optional vacuum fitting DSPL p n 701 00006 and pull a vacuum Pop off the fitting the valve seats and seals due to the pressure differential Tighten the valve stem while sealed back to the desired cracking pressure be SURE to not over tighten or the valve will be locked shut and not vent If a full vacuum about 15 psi is not needed you can leave the valve set to 2 4 psi and not have to loosen and tighten it Pressure Relief Valve 07 02 04 PRV Forward Pressure
7. rements of Sections 6 7 and 12 of the Fair Labor Standards Act of 1938 as amended and of regulations and orders of the United States Department of Labor issued under Section 14 thereof DeepSea Power amp Light Inc complies with Executive Order 11256 prohibiting discrimination in employment because of race creed sex color or national origin Limited Warranty Seller warrants that the goods except internal electronic components sold under this contract will be free from defect in material and workmanship for a period of one year from the date of shipment from the factory if they have been properly used Internal electronic components are warranted for 90 days from the date of shipment from the factory if they have been properly used This warranty will be limited to the repair or replacement of parts and the necessary labor and services required to repair the goods IT IS EXPRESSLY AGREED THAT THIS WARRANTY WILL BE IN LIEU OF ALL WARRANTIES OF FITNESS AND IN LIEU OF THE WARRANTY OF MERCHANTABILITY This warranty is the exclusive and only warranty to pass with the goods under this contract No agent employee or representative of the Seller has any authority to bind Seller to any information representation or warranty concerning the goods sold under this contract and unless an affirmation representation or warranty made by an agent employee or representative is specifically included within this contract it will not be enforceable by Buyer
8. rnia Constitution as amended by Proposition 2 effective November 7 1979 1 e Federal Reserve discount rate plus five 5 percent per annum commencing 31 days after the invoice date In the event of any litigation arising out of this contract or any efforts by seller to enforce any of the terms of this contract or to receive payment of any sum under this contract the prevailing party shall be entitled to recover its reasonable attorney s fees and costs This contract shall be interpreted in accordance with the laws of the State of California and venue for any dispute arising out of this contract shall be San Diego County California Title and Risk of Loss A Unless otherwise specified in accepted purchase order all products are shipped F O B DeepSea Power amp Light Inc plant San Diego CA and title to the property passes to the buyer at the time of shipment Buyer assumes all risk of damage to or loss or destruction of said property and no loss injury or destruction of said property shall release buyer from the obligation to pay for this shipment B Unless otherwise specified in accepted purchase order DeepSea Power amp Light Inc shall have the option of partial or complete shipment of orders and shall have the right to select the date of shipment type of carrier and routing of shipment on behalf of Customer DeepSea Power amp Light Inc will make best efforts to meet quoted shipment dates but does not guarantee to ship products wi
9. thin the time quoted DeepSea Power amp Light Inc shall not be held responsible for any failure to make delivery of all or any part of product or nonperformance of services attributable to governmental action strike or other labor dispute riots storm flood epidemic fire damage to or destruction in whole or in part of products lack of or inability to obtain raw materials labor fuel or supplies or any act of God or other cause contingency or circumstances within or without the United States not subject to DeepSea Power amp Light Inc s control which prevents or hinders manufacture or delivery of product or performance of services Termination Purchase Orders accepted by DeepSea Power amp Light Inc are not cancelable by Buyer unless all details are agreed upon in writing by DeepSea Power amp Light Inc and Buyer including Buyer s agreement to assume termination charges required by DeepSea Power amp Light Inc Returns A No product will be accepted for return repair or replacement without first obtaining a Return Merchandise Authorization RMA number The following information will be required 1 Date of Shipment 2 Invoice Number and Sales Order Number 3 Customer Purchase Order Number 4 Any relevant technical data for failure description and circumstances B New unused undamaged fully operational standard stock parts may be returned for credit only with prior written authorization and will be subject to a

Download Pdf Manuals

image

Related Search

Related Contents

SHB106 User Manual VA2    デジタルカメラ / ICレコーダー / 双眼鏡 デジタルカメラ / IC  MANUEL D´UTILISATION  Sony BLT-UHM1 Operating Instructions  外からの刺激を受けると  無線LAN JRL-710AP3/AL3 取扱説明書 [第1.3版]  2. - Vivitek  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.