Pipe & Duct Inspection Probe & Reel Set
Contents
1. 1 YEAR C WARRANTY Shop online at omega com e mail info omega com For latest product manuals omegamanual info P16PIP Pipe and Duct Inspection Probe and Reel Set CE OMEGA OMEGAnet On Line Service Internet e mail omega com info omega com Servicing North America U S A ISO 9001 Certified Canada OMEGA Engineering Inc 976 Bergar One Omega Drive P O Box 4047 Laval Quebec H7L 5A1 Canada Stamford CT 06907 0047 Toll Free 1 800 826 6342 TEL 514 856 6928 Toll Free 1 800 826 6342 Tel 203 359 1660 FAX 514 856 6886 e mail info omega ca FAX 203 359 7700 e mail info omega com For immediate technical or application assistance U S A and Canada Mexico Latin Ameica Sales Service 1 800 826 6342 1 800 TC OMEGA En Espa ol 001 203 359 7803 Customer Service 1 800 622 2378 1 800 622 BEST FAX 001 203 359 7807 Engineering Service 1 800 872 9436 1 800 USA WHEN info omega com mx e mail espanol omega com Servicing Europe Benelux United Kingdom Managed by the United Kingdom Office ISO 9001 Certified Toll Free 0800 099 3344 TEL 31 20 347 21 21 OMEGA Engineering Ltd FAX 31 20643464 e mail sales omegaeng nl One Omega Drive Czech Republic River Bend Technology Centre Frystatska 184 Northbank 733 01 Karvin Czech Republic Trlam Manchester M44 5BD Toll Free 0800 1 66342 TEL 420 59 6311899 United Kingdom FAX 420 59 6311
2. depth of 33 ft 10m and flexible enough to make two or more depending on conditions inside the pipe 90 bends in a 1 6 in 40mm I D pipe e Stainless steel camera head is immune to bathroom toilet cleaner pipe and drain cleaning chemicals gasoline brake transmission fluid and machine oil e Steel probe reel is sturdy and dust tight to IP6X standard works vertically or horizontally and has bracket for H16 HHB1600 console SAFETY INSTRUCTIONS CAUTION Do not use the P16PIP to inspect ducts known or suspected to contain live electric wiring WHAT S IN THE CASE The P16PIP Pipe amp Duct Inspection Probe amp Reel Set comes in a hard plastic protective case along with this user s manual and the following accessories e One spherical metal ring for centering the probe in 2 in I D pipes e One brush set for centering the probe in 4 in I D pipes e One brush set for centering the probe in 6 in I D pipes e A 5 64 in Allen wrench for attaching the 2 in probe centering ring e A plastic bag containing five spare 5 64 in Allen screws PRODUCT OVERVIEW Fig 1 shows the key components of the P16PIP Fig 2 details the anatomy of the camera tipped end of the probe Familiarize yourself with the names and positions of these components before moving on to the Setup and Operating Instructions Fig 1 The key components of the P16PIP Handle Borescope console holder R
3. in Before cleaning the P16PIP disconnect the HHB1600 console from the probe remove the console from the mounting bracket and cover the probe connector with the red protective cap as shown above All parts of the probe and reel can be hosed down or cleaned with a cloth and water or a mild solvent After cleaning allow fluid to drain from the unit for at least five minutes Then dry the unit carefully with a second cloth before returning it and any accessories to the plastic case Note All compatible consoles and probe controllers are NOT waterproof Be sure to disconnect your borescope and move it out of the way before washing the P16PIP SPECIFICATIONS PROBE amp CAMERA Camera Head Diameter 1 1 in 28mm Probe Diameter 0 23 in 6mm Probe Length 72 ft 22m Probe Material Fiberglass Camera Light Source 8 white LEDs Camera Depth of Field 0 4 in 10mm to infinity Camera Field of View 150 8 diagonal Waterproof Depth IP68 50 ft 10m Operating Temperature Weight REEL Frame Diameter Dust and Water Resistance 14 to 158 F 10 to 70 C 4 9 Ib 2 2kg 11 8 in 300mm To IP65 standard Operating Temperature 14 to 158 F 10 to 70 C Weight 6 6 Ib 3kg 11 NOTES WARRANTY DISCLAIMER OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase OMEGA s Wa
4. 114 e mail info omegashop cz Toll Free 0800 488 488 TEL 44 0 161 777 6611 France g Managed by the United Kingdom Office PAX m OILTE e mail sales omega co uk Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 0800 6397678 TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 e mail info omega de It is the policy of OMEGA Engineering Inc to comply with all worldwide safety and EMC EMI regulations that apply OMEGA is constantly pursuing certification of its products to the European New Approach Directives OMEGA will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but OMEGA accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used for human applications OE OMEGA PIPE amp DUCT INSPECTION PROBE amp REEL SET USER S MANUAL P16PIP Please read this manual carefully and thoroughly before using this product TABLE OF CONTENTS INTROGUGHION aoia a dace anda ielata ease 1 Key Features sidceis dccrchrse thou duvioud 1 2 Safety Instructions 0 00 c cece cee ees 2 What s inthe Case 0c c eee ee eee 2 Product Overview cc cece cece eens 3 4 Setup Instr
5. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABILITY The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INOUIRIES Direct all warranty and repair requests inqui
6. Refractometers A Pumps amp Tubing lA Air Soil amp Water Monitors iA Industrial Water amp Wastewater Treatment A pH Conductivity amp Dissolved Oxygen Instruments M5156 0612
7. chine readable form in whole or in part without the prior written consent of OMEGA ENGINEERING INC Where Do I Find Everything Need for Process Measurement and Control OMEGA Of Course Shop online at omega com TEMPERATURE A Thermocouple RTD amp Thermistor Probes Connectors Panels amp Assemblies iA Wire Thermocouple RTD amp Thermistor L4 Calibrators amp Ice Point References A Recorders Controllers amp Process Monitors A Infrared Pyrometers PRESSURE STRAIN AND FORCE iA Transducers amp Strain Gages iA Load Cells amp Pressure Gages iA Displacement Transducers A Instrumentation amp Accessories FLOW LEVEL lA Rotameters Gas Mass Flowmeters amp Flow Computers IA Air Velocity Indicators A Turbine Paddlewheel Systems L4 Totalizers amp Batch Controllers pH CONDUCTIVITY iA pH Electrodes Testers amp Accessories A Benchtop Laboratory Meters A Controllers Calibrators Simulators amp Pumps A Industrial pH amp Conductivity Equipment DATA ACQUISITION A Data Acquisition amp Engineering Software A Communications Based Acquisition Systems A Plug in Cards for Apple IBM amp Compatibles A Data Logging Systems A Recorders Printers amp Plotters HEATERS VA Heating Cable A Cartridge amp Strip Heaters A Immersion amp Band Heaters iA Flexible Heaters A Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL VA Metering amp Control Instrumentation l4
8. eel frame mtr Coiled probe Camera head Probe guide camera head stopper Reel stopper 1 F X Probe connector to borescope console or handle controller Fig 2 Structures hear the g Camera head A A camera tipped Accessory mounting ring end of the probe Rubber probe cover Metal coil spring sleeve Joint ball Probe SETUP INSTRUCTIONS ATTACH BORESCOPE The P16PIP is compatible with the following systems and components from General e The HHB1600 and HB1800 Recording Video Borescope Inspection Systems To attach the probe amp reel set to the HHB1600 or to the HHB1800 handle controller first remove the red protective cap from the Probe connector See bottom of Fig 1 Then pull back the metal collar of the DTT connector to expose the alignment key with a red dot Keeping the collar pulled back align this dot with the red dot on the connector of your borescope console or handle controller and push the two connectors together To secure the connection release the collar and turn it clockwise until tight The following figure shows the final attachment step for the HHB1600 Console At the top of the P16PIP is a metal bracket designed to securely hold the HHB1600 console If you are using the probe with a HHB1800 system General suggests not mounting the system s transmitting handle contr
9. ing any of the three probe centering accessories to the probe play out a few feet of the ge probe from the reel To do so first Z unlock the reel by separating opening the Velcro closure called the Reel stopper see Fig 1 and figure at right Once the reel is free to move grab g the probe below the camera head and begin pulling it horizontally rather than vertically as shown at WA a 4 right ES A AT Extract just enough probe for the AN liA O Joint ball to pass the Probe WAZ NN guide camera head stopper see Fig 1 Then if this is the first use E z of the P16PIP or its first use in months pull and push the end of the probe back and forth a few times see figure at right to reduce any friction binding the reel s stationary and moving parts Once you have played out a few feet of probe lock the reel by fastening the Velcro closure around the reel frame as shown below i il J ac You can now attach the 2 in spherical ring the 4 in brush set or the 6 in brush set to the probe tip To attach the ring slide its slightly larger open end over the camera head it fits only one way until the head protrudes about 1 8 in past the ring s other opening In this position the ring s Allen set screw will line up with the Accessory mounting ring of the camera head see Fig 2 Secure the ring
10. oller or receiving console Both components can be placed anywhere convenient as long as it is dry Neither component is waterproof or water resistant OPERATING INSTRUCTIONS Before inspecting a pipe determine its inner diameter Then determine whether that diameter matches the diameter of any of the three included probe centering accessories 2 4 or 6 inches If your pipe is one of these three sizes attaching the correct accessory will keep the camera head in the center of the pipe as you push the probe forward A centered probe will be easier to push forward and produce higher quality videos and photos as well If the inner diameter of your pipe is nof 2 4 or 6 in you can still use the probe to good effect without the benefit of a probe centering accessory You may have to exert a bit more effort to keep the camera head from getting hung up on the pipe s sidewalls as you push the probe forward That is more likely if you use the probe to inspect large pipes or rectangular ducts In such situations friction will often cause the camera head to tuck under the probe as you push it forward producing a rear facing dynamic view of the pipe s interior When you begin to reel in the probe however the metal coil spring sleeve see Fig 1 will free the camera head and point it forward Videos and photos captured during this return trip can be just as valuable as forward facing evidence ATTACHING AN ACCESSORY Before attach
11. ries to the OMEGA Customer Service Department BEFORE RETURN ING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The as signed AR number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the FOR NON WARRANTY REPAIRS consult OMEGA following information available BEFORE contacting for current repair charges Have the following infor OMEGA mation available BEFORE contacting OMEGA 1 Purchase Order number under which the product 1 Purchase Order number to cover the COST was PURCHASED of the repair 2 Model and serial number of the product under 2 Model and serial number of the product and warranty and 3 Repair instructions and or specific problems 3 Repair instructions and or specific problems relative to the product relative to the product OMEGA s policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in technology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC Copyright 2012 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or ma
12. rranty adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that OMEGA s customers receive maximum coverage on each product If the unit malfunctions it must be returned to the factory for evaluation OMEGA s Customer Service Depart ment will issue an Authorized Return AR number immediately upon phone or written request Upon exam ination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized mod ification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written
13. to the head by using the included Allen wrench to tighten the screw as shown at right To attach either probe centering brush set identify the end with three set screws Passing the camera head through the other end first slide the probe through the brush set until the camera head protrudes 1 8 in past the end with the set screws see figures below In this position the three set screws will line up with the head s Accessory mounting ring Secure the brush set to the head by hand tightening the screws Screw holes OPERATING amp MAINTENANCE TIPS The reel operates equally well in a horizontal or vertical position The bracket for the HHB1600 borescope console at the top of the P16PIP has a flexible obedient stem that allows the console s screen to be angled to a comfortable viewing position DO NOT BEND this stem at an angle greater than 90 see figures at right below Before attempting to wind the probe back onto the reel remember to unlock the reel by undoing the Reel stopper see Fig 1 The most effective way to rewind the probe is to push it onto the reel through the bars of the Probe guide see Fig 1 horizontally from a distance of about 12 inches Continue pushing until the Joint ball has passed through the Probe guide Stop when the camera head meets the Camera head stopper see figure at right below 12
14. uctions ccc cee eee eee 4 5 Attach Borescope ccce cece eens 4 5 Operating InstructionS 00 00 cece eee 6 8 Attaching an Accessory 00000 eee 6 8 Operating amp Maintenance Tips 9 10 Specifications 0 ccc cee ees 11 INTRODUCTION Thank you for purchasing the Omega Engineering Inc P16PIP Pipe amp Duct Inspection Probe amp Reel Set Please read this manual carefully and thoroughly before using the product The P16PIP is a probe and reel set that when attached to a video borescope inspection system from General allows plumbers to visually inspect the interior of water and sewer pipes carrying running water and HVAC specialists to visually inspect the interior of ducts In both applications inspections can be documented with video clips and still photos to provide evidence and the location of blockages or cracks The probe and reel set is compatible with the e HHB1600 and HHB1800 Recording Video Borescope Inspection Systems KEY FEATURES e Ideal for examining the interior of water pipes sewer pipes and HVAC ducts Especially tailored for 2 4 and 6 in D pipes by included probe centering accessories e 72 ft 22m long probe with 1 1 in 28mm diameter camera head e Eight super bright white LEDs give probe 640 x 480 pixel VGA resolution superior optics yield excellent depth of field of 0 4 in 10mm to infinity e Probe is water tight to IP68 standard
Download Pdf Manuals
Related Search
Related Contents
Women - wickedwomangroup.us Samsung GT-S5510 User Manual 五所川原市開発指導要綱(PDF/434KB) Mercedes SPPS MODEL 6002B - Associated Equipment Corp. Traffic Collision Database Manual Biostar Hi-Fi Z87W Ver. 5.x Fisher-Price RAINFOREST M6711 User's Manual Siemens Switch 480V User's Manual Copyright © All rights reserved.