M-200 Series Outdoor Microwave Barrier Installing Manual

image

Contents

1. amp R when the detection area not cover the practical installing area it is necessary to confirm the suitable installing site of T by TEST 4 Ribbon Steel Installing use ribbon steel to fix the device when post diameter more than 43mm Ribbon Steel is optional components 5 Cross and Overlap Installing In order to avoid dead zones of the perimeter and to enlarge the protected area recommend to install multiple M 200 systems work together by crossing or overlapping The installing eliminates dead zones and guarantees system s availability and safety See fig 6 Overlap installing requires the microwave barrier overlap with protected area at a suitable angle The minimum overlap must exceed 1 5 2 m for effective coverage depends on the sensitivity setting and installation height The optimal way is to install transmitters T only or receivers R only at the point of overlap See fig 7 6 Channels Setting Optional components the microwave barrier works only when T amp R are set in the same frequency M200MT has 4 frequencies CH1 CH2 CH3 CH4 for option can be set by jumper very easy to use See fig 9 10 Fig 4 Getthe cable through water proof connector to link dete ctor fix the connector tightly Fig 6 tee Install front cover Wall installing release the detector as fig 1 install as fig3 fig5 Receiver Receiver NA n aS do o g ei x J g i Transmitter i Sly E Transmitte
2. Terminal Connect Tamper Terminal to a 24 hour protected zone of control panel if the front cover of the detector IS Opened an immediate alarm signal will be sent to the control panel C NC amp NO Terminals Connect C NC amp NO Alarm Output Terminal with input terminal of panel notice NO Terminal is optional output SSS e TEST T2 T4 V V NO C NC TAMPER V Fig9 Transmitter connection Control Panel Connection Example TP 428 7th Zone l Alarm output and tamper connection picture Onnection 1 AUX 12V i S GND S KEY S CLK S DATA l Receiver i Remote test i button D input i Connection 2 TEST T2 Ti V V a fe rr ee ee a Modulation Fig 11 After installation adjust the receiver and transmitter to a face to face status Make sure that the antenna s radiating surfaces of R and T are parallel radiating surface is perpendicular to the virtual direct line Fig 12 is the correct installing height fig 13 is supposed to adjust the installing height Radiating surfaces paralled gt ba K m M Transmitter j cil Transmitter Receiver aay Fig 13 Receiver Fig 12
3. are correctly connected See fig 15 3 Power on when confirm there is no person walking or moving object in protected zone wait 3 minutes until the detector from Receiver Fig 15 Multimeter stand by to working status 4 Refer to fig 14 to adjust and align the R amp T first try to extinguish the Green LED to the least then make ANALOG output voltage reach max value suggest adjust at least 1 Green LED extinguished 5 Pull out the S2 Terminal to shut the indicator after adjustment 6 Walk Test Supply 10 5V DC 24V DC to system after adjusting the sensitivity after 3 min warm up time do walk tests 5m away from T amp R and in the middle of T amp R respectively after ensuring that there is no person walking or moving object in protected zone 4 7 Use wrench to fix the detector on the poles steadily i Notice The interval of each walk test is 20s walk ed yy towards the base line of protected zone by 0 5 3m s Transmitter E 5m gt 4 Receiver 2m away from the protected zone after crossing Test person weight 50 80kg the height when person bows should be within 0 8 1m of the detector s installing height 1 Walk Test should be performed at least once a year to guarantee proper operation and effective coverage of the detector 2 Remote Control Test should be performed once a week The receiver will send the alarm signal to control panel and latter will alarm accordingly wh
4. Adjustment See fig 14 first counter clockwise rotate the lock ring to relax the T or R then adjust its position till it focus the other half at last clockwise fix the lock ring Angle of i Clockwise fix depression adjust elevation adjust Horizon adjust the lock Ring Counter clockwise rotate To relax the Lock ring LED Status Instruction see fig 15 Pig Red LED ALARM Alarm status indicator it will extinguish when there is no person walking or moving object in protected zone after adjustment It will alarm and lit when detector finds person access the protected zone the LED also lit even the T not focus to R Red LED ALARM Flashes means voltage is low flashes and 4 Green LED also lit means weak signal Green LED LEVEL AGC Auto Gain Control circuit status indicator the stronger signals it received the more indicators extinguish Detector is in max gain state when 4 Green LED lit Even 4 Green LED all lit the detector still works normally The relationship between 4 Green LED and signal intensity is dis played by binary system left to right binary system high order low order signal intensity weak strong Adjust Procedure 1 Refer to fig 12 14 to make the R and T aligned 2 Connect multimeter set to DC 10V to ANALOG Terminal of Receiver make sure the polarity
5. be considered in practical installing Also prevent installing near rainspout within 5 meters and signal shield places metals steel reinforced concrete etc If there s a narrow slit width less 2m in protected zone it probably will shorten detection range max 50 attenuation according to environment Warning Please do not press hard on the antenna s radiating surface in installing Installing Method 1 U shape fixed loop installing for pole installation use the metal material to build the installed poles poles diameter 38 43mm refer to fig 2 and fig 3 Notice The bottom of plastic housing should Counter clockwise rotate the lock ring to release the main frame re move front cover Fig2 Fix the U shape loop to the post install bracket Fig 3 Clockwise rotate lock ring to fix main frame to the bracket be 0 8 0 9m to the ground or grass this is very important and make sure the poles are fixed steadily and combine with compo nents tightly 2 Fixed installing e g Wall mount refer ring to fig 6 3 Fence wall Top installing If the detector is installed on top of fence wall to prevent intrusion by climbing the distance from installing bracket to fence s top cannot exceed 0 2m the distance from detector to ground cannot exceed 2m the max detection length cannot exceed 100m in this case and make sure there isn t any fence wall blocking the signal transmitting between T
6. en making the walk test as fig 16 the alarm signal of receiver lasts about 3s Red LED lit lasts 3s Remote Control Test Connects a remote control testing button to control panel and provides a5 12V DC to the TEST Terminal it will output an alarm signal to the receiver when press the button refer to fig 11 P N 980120M20001 Ver 1 0 M 200 Series Outdoor Microwave Barrier Installing Manual M 80 M 200 M 200MT is a bi station microwave detector for outdoor application it consists of transmitter T and receiver R and the detection range can reach max 228m M 80 M 200 M 200MT microwave barrier comes with self adapt ing circuit which can effectively eliminate false alarms while maintaining high security standards for the detection of human intruders in the protected area Apply microwave modulating detection technology which owns high sensitivity of passive detection and low false alarm rate of active detection it s detection range is a three dimensional protection zone not just lines like beam sensor It s very suitable for various complicated perimeter protection like uneven ground environment etc it can easily be installed on any type of fence or pole to provide a solid barrier protection and detect all possible perimeter intrusion This barrier rejects interferences of small animals like birds cats due to its original method of false alarm elimination Several M 200 systems can be combined to provide a complete perimeter protect
7. ion with unlimited space or shape The M 200 is designed for continuous round the clock operation and keeps working at a wide temperature range of 40 Cup to 65 C and max ambient humidity up to 100 Features Microwave frequency 9 5 10 525 GHz Modulating frequency 4 channels for M 200MT Sensitivity High Low 2 grades for option Max length of protection zone M 80 outdoor 100m 330ft M 200 M 200MT outdoor 228m 750ft Max width of protection zone About 2m Nar 3 5m Wide Max height of protection zone About 2 5m Nar 4 5m Wide Working Temperature 40 C 65C Waterproof IP65 lt a Power supply 10 5V 24V DC Electric current lt 60mA 12V DC one set for M 200 Alarm Output 3Sec N C 28VDC 0 1A N C amp N O for M 200MT Photo MOS Relay Tamper output N C 28V DC Max 0 3A Response speed 0 1m 10m s moving intruder speed Ground unevenness 0 3m Height of obstacles Grass etc 0 8m snow 0 5m Dimension 156 6mm X 138 4mm X 46 5 mm Weight per set 1 1Kg 138 4mm lt Top View Installing height 0 8 0 9m Protected zone max length 228m T Protected zone max height 4 5m Protected zone max width 3 5m 9069 HH HHHHHHH 00o ie y 7 4 VASANN Grass etc Plants max height 0 3m AY a i f NX Snow cover max thic
8. kness 0 5m Fig 1 YPM A 4_ F UA RUA A VA WAG abe PI ZANNA I A WI hl N WIAA The installing site see fig 1 Notice The protected zone must be free from obstacles of human height trees and moving objects the height of grass or bushes cannot exceed 0 3m The snow depth cannot exceed 0 5m in winter It is available to adjust the installing height of de tector according to the snow depth user has to take into account as detector cannot find intruder below the snow when its depth reaches 0 7m L 10 228m L stands for protected zone length vary from 10 228m The Detection Width W vary as practical Fig 2 Detection Length L max Detection Width of open area can be calculated by the formula W 1 L 80 m Other notices Itis not supposed to have vehicles moving along with the protected zone within 2 meters or great woods grown nearby Detector should be installed 3 meters away from highway or railway be at least 20 meters away from 35KV High voltage surge 30 meters away from 500KV High voltage surge if detectors installed parallel with High voltage line recommend installing the routing wires under the ground or coupled with metal conduit tube Detector should be installed in smooth face of constructions fence or barrier the unevenness within 0 3m the distance from construction s top to detector should be within 0 6m 1 2m and the jumping intrusion should
9. r NS 0 ra Fs S Receiver Fig 6 Overlap Fig 7 Overlap installing installing to Df a jap prevent dead Transmitter ee evel zone Bec Fig 8 Enclosure space protection paired overlaps Advice If customer using single frequency Microwave barriers M 200 M 80 for cross or overlap installing suggest to leave at least 30 degree when install 2 Receiver at the same location it s to reach the best performance and prevent intereference of each other Wiring Instructions Refer to the chart below and confirm the wire s gauge used for one pair Transmitter amp Receiver the distance is the farthest pair to the power supply Divide the distance if apply several pairs of detector Wiring distance divide pair NO Max wiring distance Transmitter wiring connection as fig 9 V amp V Terminals Connect to power supply 10 5 12V DC T1 amp T2 Terminals Connect T1 amp T2 Tamper terminals to a 24 hour protected AWG M 80 M 200 zone of control panel if the front cover of the detector is opened an immediate alarm signal will be sent to the control panel AWG22 200 900 180 730 TEST Terminal TEST signal input terminal detector will send an alarm sig 2900 2580 5000 nal when inputting a volt signal of 5 25V DC practically Receiver wiring connection as fig 10 V amp V Terminals Connect V amp V to power supply 10 5 24V DC Tamper

Download Pdf Manuals

image

Related Search

Related Contents

M30245 Group User's Manual    Black Box EME149A-20 User's Manual  Kenroy Home 32192MB Instructions / Assembly  Kantech MSRP Price List North America  MODE D`EMPLOI DU SCOT À L`USAGE DES PLU  Getting Started - Pdfstream.manualsonline.com  3.4.3. Windows 2000/XP - Authorization Key - Manual  LG M4212C-BH  Mise en page 1  