Home

Cat. No.CO5120BNA

image

Contents

1. CARBON MONOXIDE ALARM AC DC USES STANDARD 9V BATTERY NEW CO5120BNA Series Carbon Monoxide Alarm e Easier Less time to install e Sleek low profile design Features U C zL LISTED CSA 6 19 01 Benefits Centered Quick Connect wiring harness Universal Mounting Bracket Easy opening pivoting side load 9V battery compartment 9V battery is pre installed Interconnectable up to 12 multiple station CO5120BNA alarms 3rd Generation electronic CO sensing circuit Operates on 120VAC with 9V battery back up Latching alarm indicator Single Test Silence button Provides quick and easy connection to AC power Center mounts to any standard electrical junction box up to 4 octagonal without screw removal Large opening for wiring connects to unit every 60 degrees for easy alignment and quick installation Does not warp due to drywall imperfections Same size footprint as other BRK Electronics smoke alarms No need to remove the unit from the ceiling to replace the 9V battery Just pull the mylar tab from the battery drawer and the battery is connected Unit that detects carbon monoxide identifies itself and sends alarm signal to other units connected in series Low power consumption 085 amps standby 087 amps in alarm Reduces nuisance alarms Red LED indicates which power supply is active AC or DC The latching alarm feature indicates which unit s in an interconnected series has
2. 731 8267 CARBON MONOXIDE ALARM 120 V AC HARDWIRE W 9V BATTERY BACK UP 8 The CO alarm will have a latched LED that will indicate which CO alarm s in the series detected alarm levels of CO Latch is manually reset 9 The CO alarm shall have an internal gasket to prevent the intrusion of outside air tht might otherwise infiltrate the unit and clean carbon monoxide from the sensing chamber 10 The unit shall be capable of operating between 40 F 4 C and 100 F 38 C 11 The CO alarm will be interconnectable with up to 12 units of its own type TECHNICAL SPECIFICATIONS Alarm Circuit Solid State Operating Voltage 120V AC 60 Hz 9V DC back up Operating Amibent Temp Range 40 F 4 C to 100 F 38 C Operating Humidity Range 10 to 90 relative humidity RH Alarm Horn Rating 85dB at 10 ft Alarm Reset Automatic when CO clears Single Test Silence Button Tests all functions by electronically simulating the presence of CO Resets the latch feature Silences the alarm while the occupant s respond to an alarm After the initial silence period if levels of CO present still indicate a potentially dangerous situation the alarm will sound again Alarm Status Indicators Battery Status Indicator Red LED flashes approximately once per minute when unit is operating on battery power only Horn chirps once per minute when battery becomes low Service Status Indicator If unit is not operating properly Red LED fla
3. ABO The CO5120BNA has a repeating temporal horn pattern 4 beeps pause 4 beeps pause The alarm has been specifically designed for residential and institutional applications including single family homes multi family homes sleeping rooms of hospitals hotels motels dormitories and other mixed occupancy dwellings as defined in standard NFPA 101 The sensor is a third generation metal oxide type It is adjusted not to detect CO levels below 30 PPM This unit will not alarm when exposed to a constant level of 30 PPM for 30 days It will alarm at the following levels under 30 to 70 relative humidity RH 400 PPM CO between 4 and 15 minutes 150 PPM CO between 10 and 50 minutes 70 PPM CO between 60 and 240 minutes According to Underwriters Laboratories Inc UL 2034 section 1 2 carbon monoxide alarms covered by these requirements are intended to respond to the presence of carbon monoxide from sources such as but not limited to exhaust from internal combustion engines abnormal operation of fuel fired appliances and fireplaces CO alarms are intended to alarm at carbon monoxide levels below those that could cause a loss of ability to react to the dangers of carbon monoxide exposure This CO alarm monitors the air and is designed to alarm before CO levels become life threatening This is only possible if the alarms are located installed and maintained as described in the user manual The Consumer Products Safety Commission CPSC rec
4. have detected alarm levels of CO Dual Function e Tests all functions by electronically simulating the presence of CO e Silences the alarm while the occupant s respond to an alarm After the initial silence period if levels of CO present still indicate a potentially dangerous situation the alarm will sound again Dicon Global Inc 88B East Beaver Creek Road Unit 6 Richmond Hill Ontario Canada L4B 4W2 info diconglobal com Tel 905 482 3270 Fax 905 731 8267 UL C LISTED CSA 6 19 01 ISO BSI Registered Firm Certificate FM21268 ZL x IRRA ne O5120BNA APPLICATION BRK Electronics Model CO5120BNA is a 120V hard wired carbon monoxide alarm with a 9V battery back up It can be operated as a single station unit or interconnected to other BRK Electronics Carbon Monoxide alarms A latching alarm indicator shows which alarm s in an interconnected series detected alarm levels of carbon monoxide These models also have a dual function test silence button during testing it will electronically simulate the presence of carbon monox ide causing the unit to alarm during an alarm it will temporarily silence the horn while residents take corrective action The CO5120B has been fully tested and complies with Underwriters Laboratories Inc Safety Standard 2034 and Canadian Standard CSA 6 19 01 for single and multiple station carbon monoxide alarms and with model building codes published by ICBO SBCCI BOCA and C
5. ommends the use of at least one CO alarm per household located near the sleeping area For additional protection install additional CO alarms on every level of the home in each separate bedroom and near each separate sleeping area It is recommended that Model CO5120BNA CO alarms be intercon nected Refer to the Model CO5120BNA user manual for more informa tion on proper location placement and installation ARCHITECTURAL AND ENGINEERING SPECIFICATIONS The Carbon Monoxide Alarm shall be BRK Electronics Model CO5120BNA or approved equal and shall provide at a minimum the following features and functions 1 Athird generation sensor calibrated to meet UL 2034 October 1 1998 and CSA 6 19 01 2 The unit should be 120V hard wired with 9V battery back up 3 In battery back up mode the battery must last for 8 hour minimum in standby and then 12 hour minimum in alarm 4 The unit should be self diagnostic and have a visual and audible alert to indicate a malfunction 5 The alarm unit must have a button that will test the alarm by simulating CO and silence any nuisance alarm 6 A solid state Piezo alarm horn rated 85dB at 10 ft that provides a temporal pattern 4 beeps paurse 4 beeps pause 7 The alarm unit will have a red LED to indicate the status of the power supply AC or DC Dicon Global Inc 88B East Beaver Creek Road Unit 6 Richmond Hill Ontario Canada L4B 4W2 info diconglobal com Tel 905 482 3270 Fax 905
6. shes three times in rapid succession every minute horn chirps simultaneously CO Alarm Status Indicator Red LED flashes rapidly horn sounds in repeating pattern 4 beeps pause 4 beeps pause when the unit has detected enough CO to trigger an alarm Unit Dimensions 5 4 Dia x 1 86 H w bracket Unit Weight 7 3 OZ Units Per Case 12 units BRK ELECTRONICS

Download Pdf Manuals

image

Related Search

Related Contents

Wissenschaftlicher Taschenrechner - GT  Olympus SP-100EE Digital Camera User Manual  Manuel d`utilisation - paramodels-rc  LG Electronics AN110B-JD Projection Television User Manual    prezzi da confermare!    Ca du 27 mars - Ecole Nationale Supérieure d`Architecture de Paris  Télécharger ce document  Samsung C108STF Instrukcja obsługi  