Home

Baudisch.SIP DoorModule MAXI / ECO

image

Contents

1. Value Hexadecimal Decimal ne 0x00 0 Do not search for DM32 0x01 1 Include module 1 in search Address 0x70 0x02 2 Include module 2 in search Address 0x71 0x03 3 Include module 1 2 in search Address 0x70 0x71 0x04 4 Include module 3 in search Address 0x72 0x05 5 Include module 1 3 in search Address 0x70 0x72 0x06 6 Include module 2 3 in search Address 0x71 0x72 0x07 7 Include Module 1 2 3 in search Addresses 0x70 0x71 0x72 0x08 8 Include module 4 in search Address 0x73 0x09 9 Include module 1 4 in search Addresses 0x70 0x73 0x0A 10 Include module 2 4 in search Addresses 0x71 0x73 0x0B 11 Include module 1 2 4 in search Addresses 0x70 0x71 0x73 0x0C 12 Include module 3 4 in search Addresses 0x72 0x73 0x0D 13 Include module 1 3 4 in search Addresses 0x70 0x72 0x73 OxOE 14 Include module 2 3 4 in search Addresses 0x71 0x72 0x73 OxOF 15 Include module 1 2 3 4 in search Addresses 0x70 0x71 0x72 0x73 All parameters listed in the table are possible to use Bold printed addresses are recommended I A restart is necessary after changing a value If a address is included to the search but no DM32 can be found the duration of starting up the DoorModule will increase 7 4 1 7 EasyLan switching functions It is possible to send up to 2 switch commands to EasyLan switching modules There are 4 values for each switching function
2. Switch function Address function 1544 dec Options for switching function 1 j 1546 dec Destination address for switch function 1 1547 dec Contact number for switching function 1 1548 dec Parameter time for switch function 1 1545 dec Options for switching function 2 P 1549 dec Destination address for switch function 2 1550 dec Contact number for switching function 2 1551 dec Parameter time for switch function 2 Baudisch SIP_Door_Module_Manual_Current doc 81 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch Parameters Options for switch commands Bit 0 switching command format Bit 0 Bit 1 2 switching command format Bit 1 00 function not active 01 2 switching command to EasyLan TM 10 switching command to SW2 with contact number address 11 2 switching command to SW2 without contact number address Bit 2 link up option Bit 0 Bit 3 link up option Bit 1 Bit 4 link up option Bit 2 000 no link up xx1 link up to door opener function x1x link up to remote command 1xx link up to CAM IO Bit 5 no function Bit 6 no function Bit 7 no function Parameters Target address for switch function The switch command is sent to this address Switching modules are usually programmed to Addresses 0x50 0x51 Relay 1 Relay 2 by factory default or there is a address used in the range 0x50 0x5F Parameters Contact number fo
3. 51 ero m E E 53 Status Remote iacet foc oret Fh e ded d nd d re sid and cea deans Font uada ida 56 vr 57 anum 58 Reset to factory settings eerie tacere eene rene EY een 59 gites Ue iof zl o 61 Technical data EUST 61 Technical drawilgsSs dtr o ote eo iter ine rrrerrrerrererrer trerre Terence terre 64 Baudisch SIP DoorModule MAXI ECO sssssssssssseseee eene nnne nennen nnns nnne nenas 64 VAR front panel aa E 65 6 2 2 1 Installations instructions V4A front panels 0 00 0 eee ee eeeeeeeeeeeeeeeeseeeeeeeteneeeeeeeeeeeens 66 How to connect lan hen nn nn na han ner er er 66 DVIS SAY S asec M 70 POWER SUDDIV acoso cn a t tpe terre errr ttre 70 Connections and operating states enne 70 Declaration Of confOrmily 2 creer tet tae dde ti ue eren addu sha ede lena xd Eia exe sr uh Eb land 72 mns EE 73 AVR firmware update center ee ee ae 73 EAS VLAN connection u ernennen 76 General information are da einen lie 76 Using an EasyLan connection iena ERTA an eura nn 76 Baudisch EasyLan field bus module and functions 4444ss440Hnnnnnnnnnn san nnnnnnnnnnnnn nn nnnn nn 76 7 2 3 1 Controlling per PC or embedded PC via an EasyLan PC interface 76 7 2 3 2 The conn
4. Baudisch SIP DoorModule Baudisch Mounting frames FB Art Nr 27 0281A D Version 1 9 As of 03 05 2012 El Baudisch Front bolted module frames for the installation of several modules with flush mounting boxes or for direct wall mount The V4A front panels are inserted into the frame Material aluminum Color light anodized powder coated on request Mounting of the module with front bolting Deliverable frame sizes single 150x150x7 5mm gt Art Nr 27 0281A double 260x150x7 5mm 2 Art Nr 27 0281B triple 370x150x7 5mm gt Art Nr 27 0281C quadruple 480x150x7 5mm gt Art Nr 27 0281D Mounting material not included in delivery contents Screw set V2A M5x12mm with 2 hole inward urge 2 Art Nr 33 1193 Screw set 4 8x50 2 hole inward urge and cavity dowels 8x40mm gt Art Nr 33 1194 Screw set 4 8x50mm torx drive and cavity dowels 8x40mm gt Art Nr 33 1195 Screw set M5x16mm torx drive with safety pin gt Art Nr 33 1196 Special bit tool for 2 hole inward urge screws 2 Art Nr 23 0169 I The built in modules shown in the picture are not included in the delivery Flush mounting box FB Art Nr 27 0282A D Flush mounting box for mounting frames with front bolting FB The V4A front panels are inserted into the frame Material aluminum Color light anodized powder coated on request Mounting of the module with rear bolting Deliverabl
5. E ea a EREET v 6660665 t6060655 t560666544 566844 s0865 06684 eees Baudisch Baudisch SIP DoorModule MAXI ECO Manual History Version Date Name Change 1 0 18 02 2010 R Bley Regenerated 1 1 07 04 2010 R Bley Enhancement KeypadModule 1 1 27 04 2010 E Czeschka English translation 1 2 07 07 2010 M B nisch Update 1 6 05 11 2010 E Czeschka Update 1 7 11 05 2011 U Meinert Corrections 1 8 02 03 2012 T Eberhardt New layout corrections update of illustrations 1 9 03 05 2012 T Eberhardt Update of Software History Approval latest version Date Name Division Initial Signature checked 03 05 2012 T Eberhardt DEV TE checked PF checked VT checked User checked FE Baudisch SIP_Door_Module_Manual_Current doc 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 4 Table of Content 1 Table o COMEN 2 2 T E A E A 2 2 General Information en ek nunc od ek e c d e x Rd RA Rd NAR 5 2 1 uelim EE 5 2 2 remise rede 5 2 3 Hardware Versions ETT 7 2 4 Fundamentals of VolP and SIP recette nenn nn re n rr NARRAR AS 8 244 MESURER 8 2 4 2 Advantages of the SIP protocol enne en nennen nnne tenen nens 8 2 4 3 Transmission and connection types of calls nennen 8 3 Product Description i ei reote itte certe
6. e Alternative call tone output for keypad available Option for Keypad Only 4 digit codes allowed DTMF may use less than 4 digits Keypad Negative acknowledgment in state CLOSE KEY CLEAR added Keypad Stop of code entry with a further push on the key symbol button Correction of parameter compensation DSP gt AVR in lib Offset code for 2 relay DTMF amp Keypad TE 03 05 2012 Baudisch SIP DoorModule V2 6 V3 7 04 10 2011 V7 3 048000 13 09 2011 V7 3 048000 V2 5 V3 5 V2 5 V3 5 16 12 2010 V7 2 047001 30 10 2010 V7 1 047001 V2 4 V3 3 Baudisch SIP Door Module Manual Current doc 6 99 Version 1 9 As of 03 05 2012 El Baudisch added DTMF call potion via keypad independent to configuration Blocking of code entry via key pad and or via DTMF through UDP command Bug fix No negative acknowledgment in case of pushed button if device between state STOP and IDLE Tone signal for button refuse conformed e Relays selectable via key pad 99x Alternative numbering of speed dialing keys at the keypad Option for blocking some key pad functions Adjustable block time between call break and another call Bug fix RTP port can t be identical to SIP port and other used ports n case of active registration and no login to the server incoming calls are disallowed Code 486 Limit of 75 speed dial numbers ch
7. e h click on OK Internet Protocol TCP IP Properties General Alternate Configuration You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP addre 192 168 0 71 Subnet mask 255 25h 255 Default gateway 192 168 0 9 Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS servel 192 168 0 wl Alternate D i i click on OK Local Area Connection Properties General Authentication Advanced Connect using E Intel R PRO 100 Network Connectio L 4 This connection uses the following items c Client for Microsoft Networks a File and Printer Sharing for Microsoft Networks vi I QoS Packet Scheduler Internet Protocol TCP IP Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks v Show icon in notification area when connected v Notify me when this connection has limited or no connectivity click on OK Version 1 9 As of 03 05 2012 Now the installed PC laptop is ready to be connected to the door module Baudisch SIP Door Module Manual Current doc 22 99 Baudisch TE 0
8. il 82 Baudisch SIP Door Module Manual Current doc 64 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 6 2 2 V4A front panel 9 Schweissbolzen 4x12mm Setztoleranz 0 5 mm A Umlaufende Fase 0 3 mm 0 30 Oberfl che V4A geb rstet Schleifrichtung vertikal zu dieser Ansicht Firmenlogo Kontur per Lasergravu Baudisch SIP_Door_Module_Manual_Current doc 65 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E z Saal Baudisch 6 2 2 1 Installations instructions V4A front panels Risk of cutting injury on the back of the front panel Risque de blessure au versu du panel de front e I By the installation of the VA4 front panel on the Baudisch SIP DoorModule be aware that the surface of the front panel can be deformed when the screws are tightened too firmly The reason is the different hardness of the welded stud VA2 and the front panel VA4 6 3 How to connect The Baudisch SIP DoorModule is in no case to be operated or charged with voltages of 230VAC If this is not followed possible lack of grounding can destroy the module to the point where voltage is applied to the housing which causes danger to life Back view of the door module a z ogee mI ig 24 SOON UW OD LILII BE PERS Al 0929098988 N DONO Un I Co he e OUTPUT INPUT X5 Maxi X2 Maxi
9. 03 05 2012 E Baudisch Example 1 DTMF code 1234 Offset code 1111 Code for 2 relay is 2345 Example 2 DTMF code 12 Offset code 0110 Code for 2 relay is 23 Example 3 DTMF code 12 Offset code 1000 Code for 2 relay is 12 This code is invalid and so the 2 relay won t work I If all digits of the offset code are set to 0 only the 1 relay will work due to a appraisal checking of the 1 code In addition the preselection of the relays by prefix code 99n or 99n have priority If the prefix code for relay 2 is selected both codes control relay 2 7 4 1 12 Form for block function selection via UDP command Parameter Address 0x061B 1563 decimal Value OxOF all functions activated Bit 0 local entry Code 1 relay 1 Bit 1 local entry Code 2 relay 2 Bit 2 remote entry Code 1 relay 1 Bit 3 remote entry Code 2 relay 2 others no function 7 4 1 13 Choosing dial tone for keypad Parameter Address 0x061C 1564 decimal Value OXMN M dial tone for entered phone number N dial tone for speed dials M and or N Dial tone 0 3 tones 425Hz and 250ms duration Pause between tones is 250ms This order is repeated every 4 seconds 1 Constant tone 425 Hz 2 Constant tone 450 Hz 3 255 Same as 0 I The loudness of the ring tone can be adjusted in setting Level of signal tones to local speaker Baudisch SIP Door Module Manual Current
10. Code of authentication Is switched only in accordance with the specified authentication code in the configuration menu Unused spaces of the password must be sent as F The authentication code always consists of 4 digits DTMF characters 0123456789 and F Proof total The proof total is formed as in the status messages The DoorModule sends a confirmation after successful verification and forwarding of the request The confirmation is only sent when the status messages were activated The data package has the status code Ox1E and as parameter is above defined remote controlled data package 1 1 sent back fills all 24 bytes of the parameter Baudisch SIP_Door_Module_Manual_Current doc 89 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 7 6 2 Additional functions The additional functions are selected by a virtual number In this case the part of the duration is the function of the parameter Number Parameter Function D 00 Deactivating the code entry lock for n 10 01 FF seconds depends on special parameter F 5A System Reset 7 7 Pin strips on the Hardware I The pin strip is not assembled because these options only are assigned for factory internal purposes Only qualified personnel should use these options Via the pin strip on the bottom board of the hardware can different settings be saved via connections of the individual pins or a special b
11. Start gt Code entry door opener 1 Start gt Dialing 2 Make a call 3 End a call 4 2 3 2 Dialing Possible numbers to choose Any phone number e Included are phone numbers in the public network or SIP numbers SIP account login e To be able to make a phone call in the public network you must have opened an account by a SIP provider and adjusted the SIP settings in the configurations menu under VoIP settings accordingly see chapter 5 4 3 SIP Settings IP addresses e VoIP capable devices in your network can also be directly dialed using their IP address Numbers of out the phone book of the door module All numbers entered in the phone book can be directly dialed as well Baudisch SIP_Door_Module_Manual_Current doc 32 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 Baudisch Entry at the 4x4 KeypadModule M I EE cd iid Ma rep Any phone number wm 1234567890 IP address Number out of the phone book of the door module mn You can end a dialing process or a call by pressing the green button with the receiver symbol Entry at the 3x4 KeypadModule luus oe cdd Dac NR nf Any phone number x 1234567890 u IP address Number out of the phone book of the door module I A call is made even after the first entered digits when no additional number is entered within 3 seconds Baudisch SIP_Door_Module_Manual_Current doc 33 99 TE 03 05 2012 Baudisch SIP DoorM
12. X1 Baudisch SIP Door Module Manual Current doc 66 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch Ee Be aware of the total load current Iges 0 2A of the 24V outputs at X2 5 X3 8 and X5 12 Respectez le courant maximal Iges 0 2A des flux sortants 24V X2 5 X3 8 et X5 12 TPINO PoE PoE over phantom power iod OV and byi middi x 48V Ln X1 TPOUTO PoE Tx PoE over phantom power INPUT middi 48V and by middi x OV TPOUTO PoE PoE over phantom power en 48V and by middi x OV TPINO PoE Rx PoE over phantom power middi OV ae by middi x 48V CAM_OUT1 To control the relay K1 on the Baudisch CP CAM module open gt inaktive GND aktive s enema 7 ja CAM OUT2 To control the relay K2 on the Baudisch CP CAM module Open gt inaktive GND aktive e I If no Baudisch CP CAM is added the DoorModule can be used as a switch with a standard 4 wire connection pins 1 2 3 und 6 via the X2 connection This way it is possible to connect a foreign device to the network via the integrated switch in the DoorModule Not available with the ECO version Baudisch SIP_Door_Module_Manual_Current doc 67 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch oa Be aware of the total load current Iges 0 2A of the 24V outputs at X2 5 X3 8 and X5 12 Respectez le courant maximal Iges 0 2A des flux sortants 24V X2 5 X3 8
13. 03 05 2012 E Baudisch With which system solutions is the Baudisch SIP DoorModule tested to date and software compatible 1 Sipgate de 3CX Free Edition Asterisk accessVoIP Asterisk Cluster FOXFON EasyPBX Swyx Siemens HiPath MO NOA PF WH o Octopus NetPhone Open Office E ME OpenScape Auerswald Compact 5010 VoIP Starface 15 Oytel There are problems with the transmission of the DTMF data No DTMF or always only the first comes through after starting the server ee eo o m s The problem should at least be partially solved as of version 4 0 build 175a according to Cytel and an internal test with an inofficial patch The transmission worked reliably over RFC 2833 With the SIP info there are still problems 16 Agfeo a Disconnection after appr 10 seconds There can be two causes e Confirmation request is set and no confirmation DTMF is sent e Server does not answer to SIP NOTIFY Snom video display Solutions e Deactivate confirmation request or send confirmation sign before 10 second deadline is passed e Remove NOTIFY URL then NOTIFY is no longer sent or use firmware from version 6 1 from test version 6a0 is the SIP stack adjusted b DTMF transmission problem Currently these units are not able to convert DTMF signals from an analog participant in SIP info or RFC2833 as of 12 2009 The only solution is to apply units solely with SIP products with new DSP because only the
14. 100 Network Connectio This connection uses the following items v E Client for Microsoft Networks v a File and Printer Sharing for Microsoft Networks M fill QoS Packet Scheduler v Internet Protocol TCP IP Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Show icon in notification area when connected Notify me when this connection has limited or no connectivity Baudisch SIP Door Module Manual Current doc 19 99 TE 03 05 2012 Baudisch SIP DoorModule b Choose internet protocol TCP IP and click on Properties Internet Protocol TCP IP Properties i Alternate Configuration Version 1 9 As of 03 05 2012 Obtain an IP address automatically Use the following IP address 182 168 You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings D on 255 255 255 0 182 168 Obtain DNS server address automatically Use the following DNS server addresses 182 158 D 8 0 9 C when the field Obtain an IP address automatically is activated then skip the following pages to k d when the Use the following IP address and Use the following DNS server addresses are activated then do not change the value
15. DTMF characters for the call buttons of the matrix module the central call button as well as the direct call button Z1 4 to GND for the number of cycles of the chain calls Status Remote Settings to activate the status message and or the remote control of for the entry port for the remote control and the exit port for the status message for the code authentication which is required for the use of the remote control for an IP address which indicates the status message to the recipient for the connection of a Snom 820 VoIP Phone 5 5 1 Audio To prevent feedback noise and reduce echoes the SIP DoorModule automatically detects if the remote intercom currently is active or not This way the direction of the speech is activated and the opposite direction toned downed It switches between the pair of values remote station speaking and remote station listening Appropriate settings can be entered here I Typical parameters are preset from the factory However they are very dependent of the installation environment and must be adjusted accordingly at the site of operation Baudisch SIP Door Module Manual Current doc 49 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 Baudisch i 1 Baudisch SIP DoorModule Precedence control Precedence switching threshold for Remote station speaking 96 Dapa Precedence switching time for Remote station speaking
16. DTMF inband analysis works Baudisch SIP Door Module Manual Current doc 96 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 9 Customer service Updates The description where you found the latest firmware and how to perform the updates is mentioned in chapter 7 1 AVR firmware update Support using FAQ Answers to frequently asked questions are found in chapter 8 FAQ E Mail support support baudisch de Baudisch SIP_Door_Module_Manual_Current doc 97 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 10 Glossary SIP Session Initiation Protocol is a network protocol to dial to control and to end a communication session between two and more participants The protocol is specified in RFC 3261 SIP is a frequently used protocol in the IP phone communication http en wikipedia org wiki Session Initiation Protocol H 323 is a protocol in the H32X serie which also includes the communication over public phone networks and ISDN http en wikipedia org wiki H323 PoE Power over Ethernet describes a method where network capable devices are supplied with energy over the 8 core Ethernet cable http en wikipedia org wiki Power_over_Ethernet Midspan By the midspan power supply a feeding device is placed between the switch and the PoE end device This way the switched feeder supplies the end device with the necessary PoE voltage
17. Press the button Open I A connection is established when the data is shown in the following form in the window Received The screen is similar to the example Empfangen Absender IP 192 168 1 200 Parameter ecc seq 3 OxDS 0x25 OxDA System idle V5F0 V1 8 V2 6 T By pressing the button Parameter HW ID the following window opens up Setup HW ID B EEPROM Zellen lesen schreiben Adresse 16 bit 9x0000 Datum 8 bit 0x00 Schreiben Datum gelesen Lesen Hardware ID HIGH 8 bit1 Ger tekennung 0x04 esen LOW 8 bit Platinenversion nm Misc 24 bit 0x000000 m Status ID read successful m Werkseinstellungen Gleiche Funktion wie Load Store Fa Jumper Laden Schlie en 8 In the Address field is the address of the parameter entered which is to be changed or read 9 In the Date field is the new value entered when you want to write 10 By pressing write or read is the corresponding action executed Baudisch SIP Door Module Manual Current doc 87 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 7 5 Status messages Status changes and current statuses can be sent as status messages via an UDP data package from the DoorModule Status messages must be activated and a recipient IP address must be entered in the configuration menu under Status Remo
18. configuration menu under hardware settings system Baudisch SIP_Door_Module_Manual_Current doc 28 99 TE 03 05 2012 Baudisch SIP DoorModule Baudisch SIP Door Module Manual Current doc 29 99 Version 1 9 As of 03 05 2012 El Baudisch Jumper table Matrix module First Second Third Fourth Fifth Module Module Module Module Module Number of contacts xzi2 gt lt 3 X7 7 8 Connecting the ring buttons on the matrix module Ring button Connection 1 Connection 2 PM rl me Tra ae X3 1 P Reference potential for all push buttons gt lt gt gt lt gt A TU nn Information on how to enter the contacts in the phone book is found in chapter 5 3 3 1 Entries in the call destination lists Connecting a keypad module With the Baudisch KeypadModule 16B Baudisch offers the possibility to connect a 16 button keypad to the SIP DoorModule MAXI If an existing keypad from another manufacturer is to be connected to the Baudisch SIP DoorModule MAXI it is possible to request an OEM hardware 4x4 Baudisch KeypadModule 16B Art Nr 33 1202 4x4 direct call module matrix other manufacturer Board for OEMs to easily connect 4x4 keypads from other manufacturers to the SIP DoorModule via screw type terminal Art Nr 33 1202P TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 3x4 direct call module m
19. doc 84 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 7 4 2 Read or write the configuration parameters These parameters can be changed with the software SIP Remote Control from Baudisch Electronic You receive the software on request E mail update baudisch de Read or write parameters with SIP Remote Control Before you can start SIP Remote Control the following configurations must be made on the web interface of the DoorModule 1 2 BR o o o o Start the configuration menu see chapter 5 2 Start of the configuration menu Choose hardware settings enter password and login standard password 1234 Choose status remote control and select the following settings IP address Here the IP address of the PC should be entered over which the parameters are changed Status port send 8112 recommended Remote control port receive 8113 recommended Status on Remote control on Save Start SIP Remote Control Open the file to be executed SIPControl exe which you received as an attachment in our e mail The following screen is shown Baudisch SIP_Door_Module_Manual_Current doc 85 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 Baudisch 3 Baudisch SIP Remote Control B Jo Einstellungen r Senden Reel 192 168 1 200 Releais IOs Remote Senden Eingangsport 8112 i 0 vo vwjO0 d Ausgangs
20. et X5 12 o 1 Connect PE protection earth to prevent dangerous situations Connectez PE connection de masse por pr venir des situations dangereuse 2 Be aware of the maximal load of the dry relay contact of REL1 2 Respectez le courant maximal pur les contacts de relais 1 et 2 3 Comply with UB 24VDC for external power supply Respectez le tension maximale UB 24VDC pour alimentation externe Protection Earth 9 EASYLAN EasyLan Bus w Ve Not available with the ECO version 2 er Ground potential Ub Operating voltage from external power supply 24VDC 1A secured te Relay closing contact s dry contacts max load 24V 2A gp Relay closing contact dry contacts max load 24V 2A o 4 Be aware of the maximum load current Imax 0 2A at the connection X3 pin 8 Respectez le courant maximal pur current Imax 0 2A at the connection X3 pin 8 5 Be aware of the maximum cable length of 0 5m to the central call button Respectez le encablure max 0 5m pour le central call button EARR ET MATRIX Z4 Direct call button 4 button matrix Baudisch SIP Door Module Manual Curentdoo 68 99 TE 08 05 2002 SIP Door Module Manual Current doc 68 99 TE 03 05 2012 Central call button closing contact max cable length of 0 5m to the button Connection for the illumination Duo LED of the central call button therefore LEDB switched from GND to 24V 5V to be constant MATRIX Z1 Dir
21. firmware Baudisch SIP Door Module Manual Current doc 75 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 7 2 EasyLan connection 7 9 1 General information e I An EasyLan connection is only possible with the Baudisch SIP DoorModule MAXI version The EasyLan Bus was developed by Baudisch Electronic GmbH to link together electronic components devices and systems in a simple manner The data bus enables secure communication between individual devices A bus segment can consist of up to 1 24miles shielded cable 2x0 6mm and can differentiate up to 64 participating devices The Baudisch SIP DoorModule MAXI has the necessary connections and can be integrated into an EasyLan system I The protocol description of the EasyLan interface is not published However it can be handed out by signing a confidentiality agreement NDA 7 2 2 Using an EasyLan connection This way the Baudisch SIP DoorModule can be controlled via field bus modules from a distance of up to 1 24miles It can process a request to make or end a call open the door or give a sound output EasyLan Bus cable length up to 1 24 miles Baudisch EasyLan interface 7 2 3 Baudisch EasyLan field bus module and functions 7 2 3 1 Controlling per PC or embedded PC via an EasyLan PC interface I There is a client software which enables the DoorModule to be remote controlled It can process a request to make or end a call open the door
22. of the display and the manual selection of a camera The door opens per mouse click with the pop up button In the same simple manner it is possible to save individual picture images by clicking or automatically by the door opening as JPG directly on the hard drive Article number 36 0204 Baudisch SIP Door Module Manual Current doc 91 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 7 8 3 Snom IP telephone with TFT display With the desktop telephone snom 820 the video image of the CP CAM is directly shown on the phone display The image display of the desired camera can always be turned on using the speed dial buttons on the phone With a suitable function of the SIP server or a direct configuration without SIP server this is also automatically possible during a call or during dialing Of course a special code at the snom 820 can also trigger the switch to open the door in the DoorModule during a call I Detailed information and application notes are received on request Baudisch SIP Door Module Manual Current doc 92 99 TE 03 05 2012 Baudisch SIP DoorModule 7 9 Version 1 9 As of 03 05 2012 El Baudisch Guide for audio settings To facilitate the setup audio settings can be changed during an ongoing call This is done using a special process the DTMF code The audio settings changed this way are not saved and after the hang up reset to the origi
23. or give a sound output Baudisch SIP Door Module Manual Current doc 76 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 7 2 3 2 The connection to the ASB 32InSPS 4OutRelais Art No 36 0133 amp sea Anschaltbausteln ASB 22inSPS AOwRalae TE x wees x14 BUS WE esee Bee oes CE ms MEUS X24 PORT A X3 RS232 2 2 PORT B Me ume rn DE 3 ioo ee PPPS PPP PPO mE opc C HHEDUA i FILEE eq Pr r eeeeeeecsn Seeeeeeeed eeeceeesce seesesescea Product details This EasyLan switch component can detect 32 input signals and release 4 output signals The inputs and outputs can be set or read via the EasyLan data bus as well as a RS232 terminal interface Supply voltage between 9 and 30V DC The inputs are electrically isolated by optocoupler and executed with a common minus potential point It is operated using a positive DC voltage between 9 and 30 V DC 16 inputs and 2 outputs are available on two 25 pin SUBD connectors male respectively The RS232 interface is designed with a 9 pin SUBD connector female which enables the connection of a PC with a 1 1 extension cable The power supply as well as the data bus connection are connected via 4 pin screw type terminals Each device has 2 such terminals which are internally direct parallel switched This enables a simple linkage of several devices All inputs and outputs are visualized by LEDs I Calls can be made and ended via the
24. the file to be executed SIPControl exe on a PC in your network The file was included as an attachment in our e mail you received The following screen is shown f S Baudisch SIP Remote Control 5 m m Einstellungen r Senden Zieladresse 192 168 1 200 192 168 1 200 168 Releais IOs Remote Senden Eingangsport 8112 i3 oger o Jo Jo f Ausgangsport ens Open CMD senden EN EM po a xlo o lb x Unlock J Ausschalten d send Code DTMF Zentralruf 1 vi2 13 vig v aie OE aa wes man Sendedaten Empfangen Absender P Status Parameter ac seg Program beenden 5 Make the following settings in the SIP Remote Control Destination address Destination of the data package The IP address of the SIP DoorModule which is remote controlled or should be updated must be entered here Input port 8112 UDP port for incoming data The setting must match the port for the status messages in the configuration of the SIP DoorModule Output port 8113 UDP port for outgoing data The setting must match the port for the remote control in the configuration of the SIP DoorModule I The specified ports are not to be blocked by a firewall on your computer otherwise the SIP remote control cannot establish a connection with the DoorModule Baudisch SIP Door Module Manual Current doc 74 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 A
25. to factory default Baudisch SIP_Door_Module_Manual_Current doc 78 99 TE 03 05 2012 Baudisch SIP DoorModule 7 4 1 7 4 1 1 7 4 1 2 7 4 1 3 em Baudisch SIP Door Version 1 9 As of 03 05 2012 E Baudisch Functions with the configuration parameters Send door opening code during a call Parameter SendDoorEnable Address 0x0603 1539d When this parameter is set to a value other than 0 a DTMF code from the phone directory can be sent to the remote station during a call by pressing the UP button twice As code is either the code of the called person sent or in case the call was made from the remote station the code of the identified participant or the code of the unknown caller Call logic Parameter CallAbortOptions Address 0x0602 1538d Value Function 0 Ending the dialing process and ending a call via any button possible 1 Ending the dialing process and ending a call via any button blocked 2 Ending the dialing process and ending a call via any other button than the one used to dial possible 3 Ending the dialing process and ending a call via any other button than the one used to dial possible as well as the selection of a new number 4 255 Works the same as for 0 Button simulation The activation of the following option of active simulation intervenes with the internal functional logic making normal operation no longer possible This option should therefore only be used by specialized pers
26. using both unused pairs of core Endspan With this type of PoE supply the switch is able to directly deliver the supply of voltage to a PoE end device without midspan feeder The feeding takes place via the data lines Baudisch SIP_Door_Module_Manual_Current doc 98 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch Herstellung und Vertrieb Baudisch Electronic GmbH Im Gewerbegebiet 7 9 D 73116 W schenbeuren Ld Tel 49 7172 92613 0 Fax 49 7172 92613 30 Mail vertrieb baudisch de Baudisch Web www baudisch de Baudisch SIP Door Module Manual Current doc 99 99 TE 03 05 2012
27. volume of the signal tones which is heard by the person at the intercom local Included are the button confirmation tones the switch on tune and action confirmation for example call ended Baudisch SIP Door Module Manual Current doc 50 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch Level of signal tones to remote station The setting decides the volume of the signaling tones which the person hears at the remote station DTMF confirmation confirmation acknowledgement door opener signaling and error tone Misc Mute time after DTMF detection The speaker at the door module is switched to mute mode as soon as the second DTMF digit is entered When the code is correctly entered the mute modus is immediately cancelled after the positive confirmation When an incorrect or an incomplete code is entered the mute modus is cancelled after the mute time 5 5 2 System i Baudisch SIP DoorModule System Audio System Relay 1 function Door opener St mote Pulse duration Drop out delay of Relay 1 1sec p ka Relay 2 function Ughitam Pulse duration Drop out delay of Relay 2 1sec p ka Door opener signalling Off Length of Announcement 1sec asec zl Extensionport Function EasyLan 4 800 bps 8E2 Keypad Option Matrix Modules DHCP Retry Timeout Pise e Save Reset Function of relay 1 relay 2 relay 2 only at MAXI The existing relays on the mo
28. 10ms fo x Remote station speaking Microphone level 96 p ka Remote station speaking Speaker level 36 Bapa Remote station listening Microphone level 26 Bapa Remote station listening Speaker level 26 papa Signalling Level of Ringtone incoming call 1 Bapa Level of signal tones to local speaker Bapa Level of signal tones to remote station 26 paba Misc Mute time after DTMF detection 1sec pagal Save Reset Precedence control Switching threshold for Remote station speaking Sensitivity of the switching to remote station speaking Be aware that the volume while speaking doesn t stay constant Switching time for Remote station speaking Delay of the return switching when below the switching threshold Remote station speaking Microphone and Speaker level Microphone level and speaker level when the switching is active Then the microphone level should be lower than with remote station listening and the speaker level should be higher Remote station listening microphone and Speaker level Microphone level and speaker level when the switching is not active Then the speaker level should be lower than with remote station speaking and the microphone level should be higher Signaling Level of Ringtone incoming call The volume of the ring tone being played back The dial and busy tones while dialing are played back with half of the preset value Level to signal tones to local speaker The
29. 3 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch k when the fields Obtain an IP address automatically and Use the following DNS server addresses are activated then click on Use the following IP address Internet Protocol TCP IP Properties i eneral Alternate Configuration You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address j Obtain DNS server address automatically Use the following DNS server addresses I enter the IP address 192 168 1 175 and sub net mask 255 255 255 0 Leave the rest of the fields blank I Choose an IP address from 192 168 1 1 to 192 168 1 254 with the exception of IP address 192 168 1 200 This IP address is being used by the door module m click on OK Local Area Connection Properties General Authentication Advanced Connect using E Intel R PRO 100 Network Connectio This connection uses the following items vi E Client for Microsoft Networks vi 8 File and Printer Sharing for Microsoft Networks v Jil QoS Packet Scheduler Internet Protocol TCP IP Description Transmission Control Protocol Intemet Protocol The default wide area network protocol that provides communication across diverse
30. 30 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch Connection diagram Matrix S1 Matrix S2 Matrix S3 Matrix S4 Matrix Z1 Matrix Z2 Matrix Z3 Matrix Z4 Connecting the 4x4 Baudisch KeypadModule 16B The 4x4 KeypadModule is connected to the SIP DoorModule MAXI at X5 see chapter 6 3 How to connect using the ribbon cable which is included in the delivery Connecting the 3x4 and 4x4 direct call modules from any manufacturer with OEM hardware from Baudisch The OEM Hardware is connected to the SIP DoorModule MAXI at X5 see chapter 6 3 How to connect using the ribbon cable which is included in the delivery The signals matrix S1 S4 and matrix Z1 Z4 are in this way easily connected to the other module via the screw type terminals X3 1 X3 8 By the connection of a 3x4 Keypad Module the connection matrix Z4 is inapplicable Terminal on OEM Hardware Signal X3 1 Matrix S1 X3 2 Matrix S2 X3 3 Matrix S3 X3 4 Matrix S4 X3 5 Matrix Z1 X3 6 Matrix Z2 X3 7 Matrix Z3 X3 8 Matrix Z4 Baudisch SIP Door Module Manual Current doc 31 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch Overview of the button functions Button function 4x4 Button function gt 3x4 KeypadModule KeypadModule Star 1 Start gt Dialing 2 While dialing Star 3 Confirmation Start gt Selection of speed dial numbers Selection of the central call
31. 5 2012 Baudisch SIP DoorModule Baudisch Version 1 9 As of 03 05 2012 5 5 4 Status Remote E Baudisch SIP DoorModule Status Remote Code for remote authentication 0123456789 2 4 Status Remote IP Address Broadcast 255 255 255 255 255 255 255 255 Status Port Transmit 1025 65534 pnz Remote Port Receive 1025 65534 Bus Status or Remote Control or SIP NOTIFY URL to Snom XML file e g 192 168 1 x snom cgi ln Save Reset Code for remote authentication To be able to remote control the code entered here must correspond with the entered code in the protocol IP Address Specifies the destination address to which the status messages are to be sent It is the broadcast address by default This way the messages are sent to all contacts in the sub net It only makes sense when several contacts in a network should receive the messages Otherwise only a direct destination address should be entered here Status Port Transmit Identification number of the application Thereby special basic conditions firewall etc can be considered Remote Port Receive Identification number of the application Thereby special basic conditions firewall etc can be considered Status Status messages are sent when this option is activated In case of deactivation no confirmations are sent not even by using the remote control function The status messages and the applied p
32. 9 TE 03 05 2012 Baudisch SIP DoorModule Baudisch Version 1 9 As of 03 05 2012 5 4 2 Codec Settings i E Baudisch SIP DoorModule Codec settings Codec favored Codec 1 PCMU z Codec Settings in listed order Dodson Poma Codec 3 Speex 7 ex coeca iBC codecs G72635 1 codecs GS T0 E Audio Frames per Tx Default 1 1 E iLBC frame size C o0ms 30ms Speex Rate 8 kbps _ Seve Reset Preferred language codec e PCMU G 711 u Law is the standard for digital communication in Europe A very good voice quality but requires also a very high data volume from appr 80 to 100 kbit s e PCMA G 711 A law is the standard for digital communication in North America and Japan Very good voice quality but requires also a very high data volume from appr 80 to 100 kbit s e Speex is for the voice transmission optimized and therefore very scalable But only the data to rate is scalable The standard setting of 8kbit s should be sufficient for understandable communication The loss of data packages makes hardly to no problem e iLBC Internet Low Bit rate Codec was especially designed for the voice transmission over IP networks It generates a data volume of appr 14 kbit s 20msec frame size or 16 kbit s 30msec frame size and is rubust in comparison to the loss of data packages e G 726 32 Generates a data volume of appr 32 kbit s by moderate voice quality e GSM 6 10 originates from the
33. Bit 0 ending the dialing process Bit 1 disconnect a call Bit 2 always execute the function at remote relay 1 Bit 3 always execute the function at remote relay 2 Bit 4 no function Bit 5 no function Bit 6 no function Bit 7 no function This function is used to end the dialing process or disconnects a call when the door opening relay was activated via the UDP remote control Each relay must be configured with the function door opener Otherwise the function is only executed when bit 2 or bit 3 is set 7 4 1 5 Activation of the DTMF relay selection Parameter EnableDTMFDoorSelect Address 0x0605 1541d If this parameter is set to a value other than 0 then the relay to be used can be selected with the code sequence 99n giving n one of the following values 0 Both relays always with a new connection or after DTMF timeout 1 only switch relay 1 2 only switch relay 2 The actual door opening code must be sent immediately after the selection sequence otherwise the selection value is reset due to the timeout I Also when the function is activated the door code can still be entered alone without preselection 99n Baudisch SIP Door Module Manual Current doc 80 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 7 4 1 6 Configure addresses for Displaymodul32 Parameter ScanDM32 address 0x0606 hexadecimal 1542 decimal Baudisch
34. Current doc 4 99 TE 03 05 2012 Baudisch SIP DoorModule 2 General Information 2 1 Symbols Warning of dangerous electrical voltage Mis en garde des tension dangereux Version 1 9 As of 03 05 2012 E Baudisch This symbol points out important references which must be followed to avoid injuries as well as 0 9 blessures ou d pr dation du syst me I This symbol points out helpful references 2 2 Software History Date DSP Version API Version 26 04 2012 V7 7 056000 V3 1 V4 3 03 03 2012 V7 5 056000 V3 1 V4 3 31 01 2012 V7 5 056000 V3 0 V4 2 14 10 2011 V7 3 048000 V2 7 V3 8 Baudisch SIP_Door_Module_Manual_Current doc damages and malfunctions of the product AVR Lib Ce symbole marques notices explicatives importante avec obligation de respecter pour esquiver Description Function Expansion Bug fix Device stops transmitting registrations in some cases Web interface java elements customized due to problems with saving with IE8 and IE9 Lock of door opener customized Reset of the tries counter at correct code entry Time for counter of tries reduced to 2 min Max number of failures increased to 4 e Customization Auto test works in devices that scan buttons in firmware not in lib Bug fixes Broadcast in local subnet fixed before only 255 255 255 255 DHCP timeout adjustable due to problems with Rapid Spanning Tree
35. In Seconds Default 60 Keep Alive Intervall 20 Seconds Default 20 System Send DTMF RFC2833 Help DTMF Payload Type 101 Range 96 to 127 Defautt 101 G 726 32 Payload Type 111 Range 96 to 127 Default 111 iLBC Payload Type Ps Range 96 to 127 Default 98 Speex Payload Type 110 Range 96 to 127 Default 110 Extended SIP Settings Support PRACK RFC3262 No C yes Required Proxy Features L NAT Traversal Disabled NAT IP poop STUN Server BE IP or URI STUN Server Port p Default 3478 _Save Reset Local SIP Port The SIP protocol which is responsible for the administration of the SIP connections is processed here via this specified port Local RTP Port The real time data transmission of the audio data is processed here via this specified port SIP Registration Timeout This setting indicates in which interval the registration by the SIP server is renewed Keep Alive Interval Indicates in which intervals an empty RTP data package should be sent to the SIP server in order for the RTP port to remain open due to a NAT firewall and alternatively a router Send DTMF Here is the method chosen over which the DTMF signaling is processed Inband Audio DTMF tones are transferred as audio data SIP info DTMF digits are transferred via the SIP protocol e RFC2833 DTMF digits are transferred via the RTP protocol Data type to be used DTMF G 726 32 ILBC Speex The dat
36. Manual Current doc 59 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch Reset to factory settings older versions 0 1 1 0 1 Turn off the power e When supply over PoE unplug the network connector at X1 INPUT see chapter 6 3 How to connect e When supply over an external power supply remove the connection Ub at the terminal X3 X4 2 Dismount the housing The jumper J3 on the bottom circuit board is now accessible from the side Top view of the audio circuit board 0 000000000000000 0000000000000000 3 Connect at jumper J3 4 Connect power 6 Wait until the booting process and the following automatic sequence are completed e Confirmation tone and LED 1 2 red yellow are lit e LED 2 red is lit e LED 1 green is blinking 6 Remove connection at jumper J3 The door module is automatically restarting The resetting to factory settings is completed The resetting to factory settings is completed I An error message in form of a single tone and a rapidly flashing red LED indicates that the Switch J3 was activated too soon In this case repeat the reset procedure Baudisch SIP Door Module Manual Current doc 60 99 TE 03 05 2012 Baudisch SIP DoorModule 6 1 Product details Technical data Version 1 9 As of 03 05 2012 El Baudisch Connections and interfaces Ethernet over RJ45 10 100 Mbit s Ethernet over RJ45 Screw type ter
37. Module_Manual_Current doc Call Keys Matrix Modules Name Number DTMF Code Incoming Outgoing Relay Group ID F Ilis loe Se up PARAAN A e ed Announcement of e o Efron E wp 2 SS a zie xh eeeemeorsi or Te none up PARAAN Reece Announcement of Ore None 41 99 TE 03 05 2012 Baudisch SIP DoorModule Baudisch Version 1 9 As of 03 05 2012 5 3 4 Phone book i a Baudisch SIP DoorModule Phonebook Name Number DTMF Code Incoming Outgoing Relay Group ID 8 ms ws Faaa Else Announcement Of Or None ules 82 no mo Fe Sed cee Announcement of E 0 Efren E Phonebook 83 Em re RT I I Ie ae ee m E Fus fie lose n cono n e n 8 Faaa freien xi weweemexorz or Efron E S LLL EE slDe si L ESIESI SI sls aller lla pe af T E SI xe Announcement Off jor None 2 7 SS Afe elTannuneemen on or None E A RI 4 4 The contact options name DTMF code and so on comply with the contacts in the phone directory with the exception they apply for all unknown callers For this reason the option for outgoing calls is missing here I The option Show number instead of label is by the SIP DoorModule ECO MAXI without a function 5 3 5 Unknown caller j E Baudisch SIP DoorModule Unknown caller DTMF Code Incoming Relay pes xls dE H nose m x Pho Unknown caller The Options Name DTMF code et
38. TE 03 05 2012 Baudisch SIP DoorModule Optional Accessories 33 1119 V4A front panel for door module Version 1 9 As of 03 05 2012 Baudisch 33 1001 Baudisch CP CAM Steel without front panel 33 1116 Baudisch ButtonModule 4 buttons without front panel and buttons 33 1144 Baudisch Central Call Button Module incl front panel 33 1202 Baudisch KeypadModule 16B without front panel 27 0235A Baudisch Mounting frame single RB 120x120x5 7mm Rear Bolting 27 0281A Baudisch Mounting frame single FB 150x150x7 5mm Front Bolting e I The optional accessories are not included in the delivery contents and must be ordered separately 13 99 TE 03 05 2012 Baudisch SIP Door Module Manual Current doc Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 3 5 Optional Accessories Name and Article Number Description Product Image Product Information Baudisch CP CAM Steel IP Video Camera Art Nr 33 1001 V4A front panel Art Nr 33 1121 Module for direct connection to the Baudisch SIP DoorModule MAXI with built in web server VGA color image with 640x480 pixel Video images can be accessed via internet browser from any PC on the network Several PCs can connect simultaneously to the camera Night vision due to IR function Without further components operational I Connection to Baudisch SIP DoorModule MAXI or directly to Ethernet possible PoE
39. a type to be used should be left on its standard setting There is no special benefit for the user here Support PRACK RFC3262 If this setting is activated specific signaling in the SIP protocol is secured Required Proxy features Characteristics which the proxy server must handle Baudisch SIP Door Module Manual Current doc 47 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch NAT Traversal Here is defined how the door module identifies its public IP address when the door module is located behind a NAT firewall or alternatively a router This can be done either by a permanent IP address for example a dedicated line with the option use NAT IP or by a dynamic assignment via a STUN server This option can be deactivated when exclusively a local network is used NAT IP Describes the IP address of the door module from the view of the internet WAN address This should automatically occur via a STUN server by a dynamic assignment STUN Server and STUN Server Port IP or URL of the server over which the current public IP address of the door module should be identified and its port number 5 4 5 System E Baudisch SIP DoorModule System settings Administrator Passwort Syslog Server IP 0 0 0 0 SNTP Server ntp1 ptb de IP or URI e g time windows com Timezone GMT 01 00 Amsterdam Berlin Berne Rome Stockholm E Automatically Adjust Clock for Daylight Saving C
40. and are then transmitted over the IP network in a specific protocol such as SIP Session Initiation Protocol Also by using an IP camera the digital video image data is sent over the same network SIP und H 323 Apart from SIP systems are also using the H 323 protocol This method can simplistically also be called ISDN over IP However it requires very powerful hardware and has several disadvantages related to firewalls and network integration The Baudisch SIP door module ECO MAXI solely supports the sustainable SIP protocol Advantages of the SIP protocol This creates substantial advantages especially in companies which already have IT networks and structured cabling Existing IT resources can be used there is no need for an additional cable network Where there is no cable connection intercoms can be operated over W LAN IP radio link This ideal intercom system provides a solution even in private homes where almost always LAN connections are found Other devices such as specific exchange or switchboard technology storage distributors or interface modules are also unnecessary Transmission and connection types of calls Direct connections Door intercom PoE switch IP phone For the simplest applications for example in a home The intercoms call the IP address of an IP phone directly By connecting several ring buttons every ring button can have a different call destination assigned Public SIP provider Door i
41. anged to 100 Bug fix TFTP Server is no longer able to send in case of wrong file names e DM32 functions added Data format for phone book changed Now there are numbers up to 31 digits supported Binary data is not compatible to versions older that V7 Bug fix Checksum in configuration block was wrong TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 2 3 Hardware Versions 17 05 2011 Improvement of the audio quality 16 12 2009 1 1 Lettering change of the layout for better overview Upper extension of the working temperature range e Sliding switch for factory settings added simplifies the accessibility by the resetting 01 10 2009 1 0 Layout with regard to the lettering an the accessibility optimized 22 09 2009 0 3 Improvement of the audio quality e Expansion microphone input regulation dynamic Steering a duo LED central call button Construction of the cover optimized 17 07 2009 Zero series layout optimization Baudisch SIP Door Module Manual Current doc 7199 TE 03 05 2012 Baudisch SIP DoorModule 2 4 2 4 1 2 4 2 2 4 3 Version 1 9 As of 03 05 2012 E Baudisch Fundamentals of VolP and SIP The transmission of voice and images over the Ethernet and by IP is increasingly replacing analog and ISDN based transmission technologies The voice communication and image are converted into digital signals VoIPZVoiceOverlP
42. atrix other manufacturer Board for OEMs to easily connect 3x4 keypads from other manufacturers to the SIP DoorModule via screw type terminal Art Nr 33 1202P I 3x4 or 4x4 direct call modules with individual connections to the 12 and 16 keys cannot be connected The DoorModule MAXI is solely designed for a 4x4 or a 3x4 direct call module with matrix circuit e I This expandability is only possible with the SIP DoorModule MAXI version 4 2 3 1 How to connect To be able to choose any phone numbers the Baudisch KeypadModule 16B or another OEM version of the hardware can be connected via the interface X5 see chapter 6 3 How to connect on the SIP door module MAXI The required ribbon cable is included in the delivery The OEM version of the hardware enables the simple connection of another 4x4 and 3x4 direct call module with matrix circuit via the screw type terminals X3 View of the OEM Hardware x3 868600 o 69666665666 LOT ORO SOROS CIO RSOICAORCIORORO In order for the keypad module to work the keypad option must be set on keypad under the hardware settings system in the configuration menu me In addition parallel to this function it is possible to connect either the Central Call ButtonModule and a ButtonModule with 4 buttons or 1 MatrixModule with 15 direct call buttons A combination with further matrix modules is not possible Baudisch SIP Door Module Manual Current doc
43. c act like the entries in the Switchboard but are only effective for unknown callers Due to this there is no option for outgoing calls I The option Announcement is deactivated in SIP DoorModule MAXI ECO Baudisch SIP_Door_Module_Manual_Current doc 42 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 5 4 Settings VoIP Network Settings The corresponding settings for the network in which the SIP DoorModule is integrated must be entered here Codec Settings Selection and setting possibilities about the used codecs SIP Settings The access data of the SIP provider must be entered here Extended SIP Settings Additional settings when required System System settings such as passwords time zone etc Baudisch SIP_Door_Module_Manual_Current doc 43 99 TE 03 05 2012 Baudisch SIP DoorModule Baudisch Version 1 9 As of 03 05 2012 5 4 1 Network i Baudisch SIP DoorModule General information Network Type Baudisch SIP DoorModule MAC address 00 50 C2 41 63 E7 Versions 056000 V7 5 v3 1 v4 3 Network settings Type of connection Manual IP Address z IP Address fi 92 168 1 200 Subnet mask 255 255 255 0 Standard gateway fi 92 168 1 1 Get DNS server IP automatically Use following IP Address Primary DNS 182 168 1 1 Secondary DNS f 392 168 1 1 Layer 3 QoS o Diff Serv or precedence value Layer 2 QoS 802 1 VLAN Ta
44. case several identical characters are used consecutively a pause of approximately a second is required between each character in order for the code to be recognized Incoming Just like for any incoming call a decision has to be made on how to proceed The options are Not answer automatic answer automatic answer with announcement and signaling an answer via a ring button The additional option beep makes sure that the phone partners hear a signal tone during the audio connection Outgoing By outgoing calls is decided if a message is to be left by the recipient for example location of the intercom Relay Here is decided whether or not the call display relay is switched on during a call If the setting on is chosen the relay remains switched on from the beginning to the end of a call Group ID It is possible to assign a group of several call destinations with this setting When a call destination out of a group is called and not reached then all call destinations out of this group are called They are called one by one according to how they are listed in the phone book Other related settings are possible in chapter under global call parameters and chain call Baudisch SIP Door Module Manual Current doc 39 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 5 3 2 Call Keys Z1 Z4 to GND In addition to the Central Call ButtonModule up to 4 direct call buttons can be connecte
45. ch Central call This setting must be changed to on in case a Central call ButtonModule is connected to the SIP DoorModule Call keys Z1 Z4 to GND This setting must be changed to on in case a ButtonModule is connected to the SIP DoorModule Call chain option In case the entered numbers were divided into groups group ID the numbers within a group are called in sequence until a connection occurs a call acceptance acknowledgement is given or the entered call chain cycle is run through The order in which the entries in the phone directory are set decides the sequence of a chain call The index in the following table shows the sequence mer e dd Phone directory rows 5 30 45 60 Baudisch SIP Door Module Manual Current doc 54 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 Baudisch Example Index contact 2 2 11 11 and 113 73 are assigned to a group ID When a contact is called within this group ID and not reached then the next contact is called and so on When the cycle is run through then the number of call chain cycles decides whether to discontinue or run through the given cycles I The function of the call chain is illustrated in the following flow chart Connection state i and acknowledgment Next Call Number Last number of the group Another cycle Baudisch SIP_Door_Module_Manual_Current doc 55 99 TE 03 0
46. d to the terminal block X4 of the door module see chapter 6 3 How to connect I In order to assign the direct call buttons to its call destinations the call destination data must be entered in the rows 1 2 4 and 8 according to the following table The names of the individual columns are found in chapter 5 3 1 Switchboard I a Baudisch SIP DoorModule Call Keys ard Z1 Z4 to GND Call Keys Z1 Z4 to GND Name Number DTMF Code Incoming Outgoing Relay Group ID 105 RES EES ERES ES ES announcement or z o None J 108 par a a HA Rees Announcement Off z or None 108 ERES ERES ERES ERES LES Announcement Off or None tor Fm mm UM Bl Arcem Of a Of Ed Nore a ao EI EI Tell E n El Announcement on s or E None m Kar a fe Sl E Announcement Of s or E None E ia RES ERES ERES ES E El Announcement Of OH Te None zl naf PAR EEE ET E Amouncement of Ifo Ziffer E iii Fall sls s El eie El announcement of s or E None E 118 ERES ERES ERES ERES ES Announcement Off or we Save Reset 5 3 3 Call keys via the matrix module I This expansion option is only available with the SIP DoorModule MAXI version The MAXI version of the SIP door module has an expansion possibility of up to a total of 76 call buttons This is possible with a series switch of a maximum of 5 Diode MatrixModules see chapter 3 5 Opti
47. dule can be triggered in different ways to carry out different switching operations Door opener By this function the relay is triggered when the called person enters a DTMF code on a keypad which is listed in the phone directory or when a specified UDP command is triggered via an external software Light camera The relay is activated by dialing at the intercom and during a call Failure The relay is activated when there is no failure It deactivates when there is no network connection only standard version no connection to the SIP server only when the registration at the server is activated and by a power outage Remote controlled No automatic function is assigned to the relay and it can therefore be remotely controlled without interaction via internal control operations per UDP Baudisch SIP Door Module Manual Current doc 51 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch Call signal By this function the relay is activated for the set duration via central call dialing This makes it possible to control a second ring or to inform a building management system of the dialing process Pulse duration Drop out delay of relay 1 door relay 2 light Depending on the assigned function the setting is either a pulse duration door opener or a drop out delay light camera There is an immediate switch by the failure notification function when a new condition is recognized By the
48. e After the entry of the new timeout value a confirmation follows and the keypad switches to idle mode The procedure activation of the configuration selection must be reaccomplished if further settings are to be made Baudisch SIP Door Module Manual Current doc 36 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 4 2 3 7 Tone signals Pressing the keys Confirmation tone pressed key No confirmation tone pressed more than 2 keys or no key Negative confirmation 1 button has currently no function Negative confirmation 2 keypad is blocked Alarm e Alarm tone sequence e Confirmation from intercom by dialing normal confirmation tone e Error tone general e Incorrect code entry e Function could not be accomplished for example call request when intercom is not in idle mode Door opener e Signal that block is removed 4 2 3 8 Ending a call A dialing process or a call can be ended by pressing the green receiver button when no entry mode is active This corresponds to pressing the ring button at the door module Ending a call is always possible even when the keypad is blocked Likewise repressing a ring button ends the dialing process or the call Baudisch SIP Door Module Manual Current doc 37 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 5 Use and configuration 5 1 Starting requirements e Connection of the SIP door m
49. e frame sizes single 138x138x41mm gt Art Nr 27 0282A double 248x138x41mm 2 Art Nr 27 0282B triple 358x138x41mm 2 Art Nr 27 0282C quadruple 468x138x41mm gt Art Nr 27 0282D I The built in mounting frames FB shown in the picture are not included in the delivery Baudisch SIP_Door_Module_Manual_Current doc 18 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch Starting up Preconfiguration After the installation to activate the door module an IP address in the address range of the network has to be assigned to it This setup can be carried out with a PC laptop which is directly connected to the door module along with an external 24V power supply see chapter 4 2 Connection Another possibility without external power would be to connect the door module to a PC laptop via a PoE switch To be able to connect to the door module it is necessary that the PC laptop temporarily is setup for the IP address range of the door module The address range is defined from 192 168 1 1 to 192 168 1 254 with the delivery The door module has the address 192 168 1 200 To configure the door module follow the coming instructions 1 Temporarily change the IP address and the address range of the PC laptop Windows XP a settings gt network connections gt LAN connection 4 Local Area Connection Properties General Authentication Advanced Connect using BP Intel R PRO
50. ect call button 1 button matrix 6 MATRIX Z2 Direct call button 2 button matrix 7 MATRIX Z3 Direct call button 3 button matrix Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 Baudisch ELE Be aware of the total load current Iges 0 2A of the 24V outputs at X2 5 X3 8 and X5 12 Respectez le courant maximal Iges 0 2A des flux sortants 24V X2 5 X3 8 et X5 12 Be aware of the maximum cable length of 1 5m to the matrix module or the keypad Respectez le encablure max 1 5m pour le keypad d MATRIX S1 Scan line 1 open collector c MATRIX_S2 Scan line 2 open collector o 9 MATRIX S3 Scan line 3 open collector s o MATRIX S4 Scan line 4 open collector hr MATRIX_Z1 Button matrix input 1 TTL o E 6 o MATRIX_Z2 Button matrix input 2 TTL ie MATRIX_Z3 Button matrix input 3 TTL S 8 MATRIX Z4 Button matrix input 4 TTL 8s 9 J OND 4QP b e jm 1 t EASYLAN EasyLan Bus e I More information about the expansion port X5 for the matrix module and keypad can be found in chapter 3 5 Optional Accessories Terminal block u Baudisch SIP Door Module Manual Current doc RESET 69 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El 6 4 6 4 1 6 4 2 Baudisch Displays The DoorModule displays different states on several LEDs on the module Power supply The power and the PoE LED are fou
51. ection to the ASB_321nSPS_4OutRelais nennnennnnen 77 Configuration Baudisch SIP DoorModule MAXI for EasyLan sse 77 Chain Operation iic reiecit ve rere iiid ote adie had eda haha daa deine 78 Speciallfunttions 2 78 Functions with the configuration parameters 4444444n40nnennnnennennnnnnnnnnnnnnnnnnennnnnn nn 79 Baudisch SIP Door Module Manual Current doc 3 99 TE 03 05 2012 Baudisch SIP DoorModule 7 4 2 7 5 7 5 1 7 5 2 7 6 7 6 1 7 6 2 7 7 7 8 7 8 1 7 8 2 7 8 3 7 9 7 10 Version 1 9 As of 03 05 2012 Baudisch 7 4 1 1 Send door opening code during a call sssssseeeeeen 79 Fam Ec UEM 79 LAAs Button Simulations Hase Hr asien uds FerinEs Eus 79 7 4 1 4 Disconnect a call after remote relay sse 80 7 4 1 5 Activation of the DTMF relay selection essseeeeme 80 7 4 1 6 Configure addresses for Displaymodul32 sssssssee eee 81 7 4 1 7 EasyLan switching functions ssssessseeeeenenennene nnne nnns 81 7 4 1 8 Mask for keypad keypad functions seseeeeeeeenenm enn 82 7 4 1 9 Alternative numeration of speed dial keys keypad ssssesssss 83 7 4 1 10 Time lock between call cancel and further dial eesesss 83 7 4 1 11 O
52. esse Baudisch SIP Door Module Manual Current doc 24 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 Baudisch 4 2 Connection 4 2 1 Baudisch SIP DoorModule connection e I First preconfigure then assemble see chapter 4 1 Preconfiguration Ethernet LAN network cable RJ45 or Ethernet LAN Ana 02 network cable RJ45 24VDC ex lt a gt wu o sa 5 z0 az Connection option 1 gt switch with PoE e Connect the door module to the PoE switch Power over Ethernet Switch with a network cable at X1 see chapter 6 3 How to connect Connection option 2 switch without PoE e Connect a 24VDC power supply 24VDC 1A fused to the OV and UB of the terminal X3 see chapter 6 3 How to connect e Connect the door module to the switch without POE with a network cable at X1 see chapter 6 3 How to connect I The description on how to connect the optional accessories follows in the following chapter Baudisch SIP_Door_Module_Manual_Current doc 25 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 4 2 2 Connecting the optional accessories To avoid damage connect the accessories in state of no power Pour pr venir des d g ts ne connectez pas les accessoires avec tension connexe Baudisch CP CAM Steel Art Nr 33 1001 How to connect The Baudisch CP CAM Steel is directly connected to the Baudisch SIP DoorModu
53. f the configuration menu unneersssenssnnennnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnnnnn ann 38 5 3 Phone DOOK vases cc M H 39 5 3 1 ME ello e nassen nase nennen essen nase angehenden 39 Baudisch SIP Door Module Manual Current doc 2 99 TE 03 05 2012 Baudisch SIP DoorModule 5 3 2 5 3 3 5 3 4 5 3 5 5 4 5 4 1 5 4 2 5 4 3 5 4 4 5 4 5 5 5 5 5 1 5 5 2 5 5 3 5 5 4 5 6 5 6 1 5 7 6 1 6 2 6 2 1 6 2 2 6 3 6 4 6 4 1 6 4 2 6 5 7 1 7 2 7 2 1 7 2 2 7 2 3 7 2 4 7 3 7 4 7 4 1 Version 1 9 As of 03 05 2012 Baudisch Call Keys Z1 Z4 to GND Henne een tete e eR Rad aue i san 40 Call keys via the matrix module sssssssssssesess esee ennemis nnne nene enne 40 5 3 8 1 Entries in the call destination lists seseee mm 41 PHONG DOOK e 42 Bnet 42 Settings VolP m H 43 no 44 Godee Settings E 45 SIP Seti NGS itsessaan a ae er end 46 Extended SIP Setlirigs siainen een 47 SI M 48 Settings Hardwate RE 49 PAU CO TE es bU LIE ERIS ID IRA uU D 49 SUCCI
54. ffset for door opener code for selection relay DTMF amp keypad 83 7 4 1 12 Form for block function selection via UDP command ussrsnneeen nennen 84 7 4 1 13 Choosing dial tone for keypad sse 84 Read or write the configuration parameters sssseeneeene enne 85 Status MESSAGES Au rn anne Er e bo edo Ce ttd eden uere a edad ue ERO E Ee Ro kae 88 Protocol na anne een 88 Messages 88 temiote 6 9 9 09 retur reir det E AL rrr 89 mis 89 Additional TUNCtONS RT 90 Pin strips on the Hardware teen dec hob aaa 90 IP Video integration with Baudisch CP CAM Steel sse 91 Video display in the web browser essssesseeeneneenen nennen nnnm nnnm nnn nennen nns 91 Baudisch SIP VideoClient eessssissssseseseseeee enne i a sterii trt n nennen 91 Snom IP telephone with TFT display sess nennen nns 92 Guide for audio settingS 0rs4400nnnannnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 93 Create ring tones and announcement messages ssssssssssseeeneeeeneen nennen 94 pe E 95 eid ume 97 GIOSSANY c POPvOOon 98 Baudisch SIP Door Module Manual
55. g fo 802 1P Priority Value o Save Reset Network settings Connection type The network settings can be either manually entered when Manual IP Address is chosen or automatically set via a DHCP Dynamic Host Configuration Protocol server IP address Here you can choose an available IP address for your SIP DoorModule out of your network I In case the IP address was manually changed the web browser can possibly no longer show the page with the response In this case enter the new IP manually in the browser to get back to the starting page of the web interface Sub net mask The sub net mask informs the door module of the size of the sub net in which it is located Standard Gateway A gateway is a transmission point between different nets The settings for the DNS Domain Name Server can be set either manually or automatically via the DHCP Server e Automatically obtain the DNS server IP When this option is chosen the fields for the primary and secondary DNS are shown gray and the IP address is automatically obtained e Use the following address If this option is chosen the primary and secondary DNS must have been assigned addresses e I The settings for QoS Quality of Service are only to be adjusted by experienced system administrators Basically these settings serve to prioritize the data packages for the voice transmission compared to other network data communication Baudisch SIP_Door_Module_Manual_Current doc 44 9
56. hanges C no yes Password to enter this web interface System Help Save Reset Administrator password Access password for the configuration of the door module via the web interface The factory preset standard password is 1234 Syslog server IP The IP address which is specified here can be used to forward system information to a Syslog server When the IP is set to 0 0 0 0 the mode is deactivated SNTP Server and Time zone The time zone for the system time and a server over which the current time is loaded can be entered here The time is set to the standard time GMT and responds accordingly without consideration of the summer and winter time To consider these the option adjust clock must be activated Baudisch SIP_Door_Module_Manual_Current doc 48 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 5 5 Settings Hardware Audio Settings for the precedence control of the speaker and microphone levels by the connection with another intercom as well as the switch barrier and switch duration Signaling settings for the volume of the ring tone and the signal tones System Settings for the function and pulse duration of relay 1 and 2 the door opener signaling the ID announcement the extended port function and the keypad options Call Opt Settings for the call duration the dialing and the redial attempts for the request for acknowledgement via
57. interconnected networks Show icon in notification area when connected Notify me when this connection has limited or no connectivity n click on OK I The address range is defined with these two entries which include the location of the PC laptop and its associated IP address Baudisch SIP Door Module Manual Current doc 23 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 2 To establish connections network crossover cable RJ45 Baudisch SIP DoorModule MAXI network cable RJ45 Baudisch SIP DoorModule ECO crossover cable RJ45 Establish connection from PC laptop to door module via PoE switch or Connect the SIP door module directly to the PC laptop with a network cable and to an external power supply 24VDC 1A fused In this case a crossover cable must be used with the ECO version 3 Start the configuration menu see chapter 5 2 Start of the configuration menu Access the starting page in the web browser using the factory preset IP address 192 168 1 200 Choose Settings VoIP and login using preset password 1234 Now you are in the sub menu network and you can carry out your network settings see chapter 5 4 1 Network em Is the new IP address saved then the configurations menu can only be accessed with this address Apr s transf rer une adresse IP neuve le menu de configuration peut seulement tre appeler avec cette adr
58. ion 0x14 Send identification A maximum of 24 characters of the optional user name SIP settings is transmitted 0x4C ByteO 0x31 Login at the SIP server successfully completed Baudisch SIP_Door_Module_Manual_Current doc 88 99 TE 03 05 2012 Baudisch SIP DoorModule 7 6 7 6 1 Version 1 9 As of 03 05 2012 E Baudisch Remote control The remote control can be used to operate the relays 1 and 2 and the camera IOs 1 and 2 Further there are several more functions Protocol A UDP data package is structured as follows ID Sender IP gt lt Seq No gt lt Output No gt lt Duration gt lt Password gt lt Proof total gt ID Identification of the protocol BSREM 5 characters ASCII Sender IP Contains the IP address of the sender as a string of hex digits 192 168 0 2 would be C0A80002 Seq No Sequence number Serves to identify the package when a number of packages is sent This way double received packages can also be recognized The sequence number is represented as hexadecimal with two digits in the range 0 to 255 00 FF Output No Output number Number of the controlled output Allowed values are 1 to 4 The number consists of only one hex digit 1 Door opener relay 2 Light relay be aware of special function in the web interface 3 Camera IO 1 4 Camera IO 2 Duration Is encoded as two digit hex string 0 off 1 on permanent 2 255 duration in seconds Password
59. ivery The button illumination is controllable GND active via an external signal at LED ON X1 4 gt Solder bridge from pin 2 to pin 3 remove and disconnect the solder bridge and conductor between pin 1 and pin 2 respectively Information on how to enter the contacts in the phone book is found in chapter 5 3 3 1 Entries in the call destination lists TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch Baudisch Diode MatrixModule Art Nr 33 1127 rey IIIILIT How to connect The first or the only matrix module is connected to the door module directly at X5 with the ribbon cable see chapter 6 3 How to connect Further modules are row like added with ribbon cables dependent of the number of needed contacts ring buttons The Baudisch SIP DoorModule can be expanded to include up to 75 contacts ring buttons using this method of cascading flat line 1 Diode MatrixModule 2 Diode MatrixModule 3 Diode MatrixModule 4 Diode MatrixModule 5 Diode MatrixModule X7 Jumper X7 Jumper X7 Jumper X7 Jumper X7 Jumper cables 16 doorbell 31 doorbell 46 doorbell 61 doorbell 17 doorbell 32 doorbell 47 doorbell 62 doorbell 2 doorbell o 15 doorbell I To make the cascading work the Jumper X7 must be correctly set on the individual modules Apply the following table In addition the keypad option must be set on matrix module in the
60. lable upon request The front panel and the buttons are not included in the delivery and must be ordered separately Baudisch SIP_Door_Module_Manual_Current doc 15 99 TE 03 05 2012 Baudisch SIP DoorModule Baudisch KeypadModule 16B Art Nr 33 1202 V4A front panel Art Nr 33 1198 Version 1 9 As of 03 05 2012 El Baudisch Keypad with blue LED illumination with the choice of any phone number IP addresses or numbers out of the Baudisch SIP DoorModule MAXI phone book Likewise every door opening code which has been entered in the phone book can be keyed in A protection function prevents the opening through several attempts Module for the direct connection to the SIP DoorModule MAXI Blue LED background illumination Possible numbers to dial Any phone number Included are phone numbers of the public network or SIP numbers of the connected SIP account To make a phone call to the public network an account with a SIP provider is needed Adjusted the SIP settings in the configuration menu under the VoIP settings accordingly see chapter 5 4 3 SIP Settings P addresses VoIP capable devices in your network can also be directly dialed using their IP address Numbers out of the phone book of the door module I The front panel is not included in the delivery of the KeypadModule 16B and bust be ordered separately Baudisch Diode MatrixModule Call button expansion with up to 75 call buttons via Ar
61. le MAXI at the connector X2 using a conventional patch cable Detailed information to the terminal assignment is found in the product manual of the Baudisch CP CAM Steel Baudisch Central Call ButtonModule Art Nr 33 1144 How to connect The Baudisch Central Call ButtonModule is connected to the Baudisch SIP DoorModule MAXI ECO in the following way Connect at the Terminal X4 at Reference button the door module Button Free assignment connection B for the two closing 25 contacts B Button connection B Connection for the illumination Duo LED of the central call button The output LEDB is switched from GND to 24V 5V is constant e I Information on how to enter the contacts in the phone book is found in chapter 5 3 3 1 Entries in the call destination lists Baudisch SIP Door Module Manual Current doc 26 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 mi Baudisch SIP_Door_Module_Manual_Current doc 27 99 Baudisch Baudisch ButtonModule 4B Art Nr 33 1116 How to connect The Baudisch ButtonModule is connected to the Baudisch SIP door module MAXI ECO in the following way Terminal X1 Terminal X4 at the button at the door Connection of the external controlling of the keypad illumination also see Jumper J1 6 vmn Mati 24 s w Jumper J1 Constant illumination of the buttons delivery status gt Solder bridge from pin 1 to pin 2 connected via conductor by the del
62. minal Female connector 12 pin Baudisch SIP Door Module Manual Current doc Ethernet with PoE gt without external supply Ethernet without PoE gt with external supply Integrated switch for direct connection of a CP CAM only by the MAXI version Grounding External supply Ub OV 24V DC 1A secured Relay closer dry contacts max loading 24V 2A for door opener Relay closer dry contacts max loading 24V 2A for call display alternatively useful for online monitoring only by the MAXI version EasyLan 24V Bus GND only by the MAXI version Button closer max cable length to push button 0 5m Output illumination central call button for two colored LED 4 inputs for external dry contact buttons for direct call triggering Binary coded for direct call to 15 contacts GND Expansionport for diode matrix module only by the MAXI version 61 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch Physical characteristics Dimensions without Baudisch VA4 panel LxBxH ca 95 x 95 x 40 mm with Baudisch VA4 panel LxBxH ca 109 5 x 109 5 x 48 mm Operating voltage 48 V by supply over PoE Power over Ethernet 24V DC 20 36V DC 1A secured by external supply Power input Open circuit operation ca 2 2W Voice transmission ca 4W Environmental conditions Working temperature 20 to 50 C 20 after 15 min running time Protection class IP 65 towa
63. mobile communications area It generates only a very low data volume by an acceptable quality The settings for iLBC frame size und Speex Rate are only to be adjusted by experienced system administrators Change le param tage iLBC Frame size et Speex Rate faut seulement tre ex cut e d un technicien experte Baudisch SIP Door Module Manual Current doc 45 99 TE 03 05 2012 Baudisch SIP DoorModule Baudisch Version 1 9 As of 03 05 2012 5 4 3 SIP Settings l Baudisch SIP DoorModule SIP settings SIP registration Cro ves ngs ing SIP Server IP or URI SIP Settings SIP Server Port 5060 Standard 5060 Extend gs SIP Domain SIP Server as Outbound Proxy No C yes Use DNS SRV no C ves SIP User ID SIP authentication ID SIP authentication PIN Username Optional e g John Q Public Save Reset SIP registration Indicates if the intercom should be registered by the SIP server If this option is not activated only direct connections IP to IP are possible A connection via call numbers is not possible SIP Server and SIP Server Port The IP address the URL of the SIP provider or a SIP telephone system is entered here The port number specifies to which port the server listens SIP Domain It serves the determination of contacts and is used for the connection buildup together with the number in the SIP protocol A connection via a call number ca
64. mote Control was developed which enables an update of the firmware over the network without opening the device Why and when should the AVR firmware be updated To keep the functions of the DoorModule warranted an update of the AVR firmware should be made after an update of the firmware is performed How do get the latest firmware and SIP Remote Control You receive the SIP Remote Control and the AVR firmware together with the e mail in which the firmware for the DoorModule was sent on your request To perform an update of the AVR firmware via the boot loader function in SIP Remote Control Before you can start the SIP Remote Control the following configurations must be made in the web interface of the DoorModule 1 Start the configuration menu see chapter 5 2 Start of the configuration menu e Select hardware settings enter password and login standard password 1234 Select status remote control and enter the following settings e P address The IP address of the PC over which the firmware update is made should be entered here Otherwise there is too much data communication in the network Status port send 8112 recommended Remote control port receive 8113 recommended Status on Remote control on Save Qe e e e Baudisch SIP Door Module Manual Current doc 73 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 Baudisch 4 Start SIP Remote Control Open
65. n not occur without it The IP address of the SIP server can be entered here instead of a name SIP Server as Outbound Proxy Use the SIP server as proxy for outgoing calls However it must also be supported by the SIP server This way telephone calls can be made through a NAT firewall Use DNS SRV To reach a contact within the SIP domain use the DNS server entry SIP User ID It is the ID within a SIP domain which is used to identify the intercom This way the assignment is processed by an incoming call That means that the caller communicates the call enquiry as lt phone number gt sipdomain com or as user ID gt sipdomain com SIP authentication ID and SIP authentication PIN User name and password for the login at the SIP server Username This field is only for information purposes and has no special function For example the call number of the door module could be entered here to simplify the administration of the SIP accounts It would alleviate the assignment of the user data to the call numbers because mostly the user IDs are different than the call numbers Baudisch SIP_Door_Module_Manual_Current doc 46 99 TE 03 05 2012 Baudisch SIP DoorModule Baudisch Version 1 9 As of 03 05 2012 5 4 4 Extended SIP Settings i E Baudisch SIP DoorModule Extended SIP settings Local SIP Port E060 Standard 5060 Local RTP Port eono Between 1024 and 65535 Default 6000 SIP Registration Timeout jo
66. nal values Reasonable values can be set permanently over the configuration menu which is described in chapter 5 5 1 Audio DTMF Code All DTMF commands for special functions are five digits and entered using the buttons on one of the phones connected to the intercom They start with a star followed by a command digit two digits for the parameter and end with the hash button DTMF code example Bam i Example2 j S For the guide to work by the change of the audio characteristics it has to be activated with 999 To be able to test the settings without delay the DTMF muting is deactivated Possible DTMF commands 00 99 Special functions Activate service mode Deactivate service mode Reset pre selection of door opener relay requires no service mode Pre selection of door opener relay 1 requires no service mode Pre selection of door opener relay 2 requires no service mode WES SES 3 losg Volume ofthe signals inthe local speaker 4 100 99 Volume ofthe signals to the remote staton e Joos Remote station speaking microphone level Switching threshold for remote station speaking 00 20 Switching time for remote station speaking value 100ms Baudisch SIP Door Module Manual Current doc 93 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 7 10 Create ring tones and announcement messages The ring tone and the ann
67. ncement via the update function of the door module see chapter 5 6 Baudisch SIP Door Module Manual Current doc 94 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 8 FAQ Which methods of DTMF transmission can be used There are 3 ways of transmission 1 Inband audio method over RTP A DTMF tone is created by pressing a button and coded via the set audio codec and then transmitted as payload voice data in the RTP package 2 SIP INFO method over SIP RFC2976 The information that a button pressed during a SIP session is transmitted as info message in the SIP data package 3 DTMF event method over RTP RFC2833 The information that a button pressed during a SIP session is recognized as DTMF event and is transmitted as payload in a separate RTP data package Cause of error when dialing is not possible disconnection shortly after activation There can be different reasons when dialing is not possible The most common reasons are related to the configuration field SIP domain e field blank not allowed e field with FQDN a filled domain without a given DNS server e Typing error in the domain or in the IP address Solutions e f in doubt enter the IP address of the SIP server when working in a local network e setup DNS server e correct the typing error Baudisch SIP Door Module Manual Current doc 95 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of
68. nd on the back side of the DoorModule and are described in the following way PWR 9 Power supply available is lit by external and PoE supply POE 9 Power supply over PoE available is only lit by PoE supply Connections and operating states 4 additional LEDs are visible in a recess on the side of the DoorModule as shown in the picture mem LED2 LED1 IN OUT IN Is lit with a network connection at X1 OUT Is lit with a further connection at X2 Fluttering LEDs signals data communication The OUT LED is only available with the SIP DoorModule MAXI version The operating states which are shown by the LED1 and LED2 are found in the following table Baudisch SIP Door Module Manual Current doc 70 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch Description of the operating statuses of LED1 and LED2 Description If the device is supplied with power then it is in idle state and the connection with the SIP server is established If the device is supplied with power then it is in idle state and the connection was not established or cannot be established Indicates the calling state or the dialing process from the intercom to an external party An incoming call is not indicated here Transition state Special functions The function factory settings load save is accessed or entry in the save mode Alternate blinking The device is in save mode blinking Factory settings l
69. nected e There is a cheaper ECO version available where the connection possibilities are limited to a maximum of 5 ring buttons and one relay for the door opening The model MAXI has in comparison to the ECO version a second relay a built in Ethernet LAN switch for the connection and supply of a Baudisch CP CAM or a linkage of several intercoms a Baudisch EasyLan Bus for the connection of Baudisch switch components and a cable ribbon connector for a keypad module or for matrix boards allowing up to 76 ring buttons to be connected Baudisch SIP Door Module Manual Current doc 9 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 3 2 Overview SIP telephone system Display video image Internet SIP able terminal devices remote control call build up and relive door opener relais Sound output request Ethernet Baudisch EasyLan interface till 1 24 miles Baudisch Central call ButtonModule I E17 7 BORGBERLERREREEN up to 75 doorbells Baudisch Diode Baudisch CP CAM Steel Baudisch SIP DoorModule Will Baudisch SIP KeypadModule MatrixModule This connection option is only available with the Baudisch SIP DoorModule MAXI The simultaneous operation of these connections has to be verified individually Baudisch SIP Door Module Manual Current doc 10 99 TE 03 05 2012 Baudisch SIP D
70. ntercom and IP phone are switched free of charge via a public SIP provider internet access and at least one DSL connection required Transfers from SIP to the fixed and mobile phone network are offered on favorable terms This makes the door intercom a worldwide telephone Even switching functions e g the door opening can be carried out while on the road Local SIP server software This software can be run on any PC For example the 3CX SIP server software also available as freeware runs directly on a Windows server Alternatively Asterisk is frequently installed on a Linux PC IP phone systems Many phone system manufacturers offer devices with SIP features Our door intercoms can also be directly connected there A current compatibility list is available on request Baudisch SIP Door Module Manual Current doc 8 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 3 Product Description 3 1 General Information The Baudisch SIP door module is a door intercom with internal loudspeaker hands free microphone inputs for external call buttons as well as relay outputs for door opening and light The device is the ideal solution for vandalism protection requirements or for outdoor applications It includes a phone book with 76 speed dialing numbers which can be triggered via external buttons Fast dialing and very good quality giving a clear and loud replay are the characteristic features
71. oaded saved Jumper can be removed blinking Error while loading saving the factory settings or several jumpers are attached Baudisch SIP Door Module Manual Current doc 71 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 Baudisch 6 5 Declaration of conformity EC Declaration of Conformity for devices according to EU directive 2004 108 EC EMC directive The device Baudisch SIP DoorModule with all its designs is designed to be in line with the EC directive 2004 108 EC under the sole responsibility of Baudisch Electronic GmbH Im Gewerbegebiet 7 9 D 73116 W schenbeuren The following harmonized standards are applied EMC directive EN 61000 6 2 2006 3 with the basic standards set out therein immunity to interference for industrial environment EN 61000 6 3 2007 9 with the basic standards set out therein emitted interference for residential commercial and industrial area as well as small business EN50121 3 2 2007 7 railway applications electromagnetic compatibility W schenbeuren September 1st 2009 Peter Baudisch CEO Baudisch SIP Door Module Manual Current doc 72 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 7 Extras 7 4 AVR firmware update I An update of the AVR firmware is only recommended when you have previously installed an update for the DoorModule see chapter 5 6 1 Firmware A program SIP Re
72. oard No zi Call Keys Z1 Z4 to GND No Call Chain Option Call Chain Cycles zj _Save Reset General Maximum call duration Call time limit The call is disconnected after the expiration of this term Timeout connection attempt Decides the time of how long is waited for a call to be made This parameter can also be set by a SIP provider and a SIP server respectively The dial attempt is disconnected when there is no answer Delay between redial attempts Delay between dial attempts There is a delay between redial attempts only by a chain call A dial attempt follows immediately with a phone number change Redial attempts Number of redial attempts until the dialing process is disconnected A redial attempt takes place after the preset delay time when the remote station is busy Wait for acknowledgement This function can be set when an explicit acknowledgement of a call acceptance is desired The called person must confirm the acceptance by pressing a key Otherwise the call is discontinued after 10 seconds and a new number can be dialed DTMF character for acknowledgement Choice of key with which the called person should confirm the call acceptance Call buttons matrix module This setting must be changed to on in case a MatrixModule is connected to the SIP DoorModule Baudisch SIP_Door_Module_Manual_Current doc 53 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudis
73. odule Version 1 9 As of 03 05 2012 E Baudisch 4 2 3 3 Code entry I This function is not available by the 3x4 direct call module All DTMF codes which have been saved in the phone book can be entered in order to open the door using the KeypadModule Entry at the 4x4 direct call module Sequence gt Button Number Buttons Example DTMF code max 4 digits 1234 e I An entry can be ended by pressing the button even when no code digits were entered Otherwise the already entered digits on the door module will be sent and evaluated Time block by the code entry A time block is activated for the door opening function with the KeypadModule This makes several attempts of possible code combinations difficult I When an incorrect code is entered 4 times within 3 minutes the block is activated The duration depends on the currently active time block level When the block already was activated and no 60 minutes are passed then the current time block level will be raised to the next level with a longer time block For every additional entry within an active time block the time block and the reset time for the level is restarted Level Time block min 1 3 2 5 3 10 4 20 A resetting of the time block level occurs after 60 minutes of no time block activation Likewise a resetting of the time block and time block level takes place after a power break Example The code was 4 times incorrectly entered a
74. odule with an Ethernet 10 100 LAN The supply of current can take place over the Ethernet via PoE Power over Ethernet or with a suitable power supply 5 2 Start of the configuration menu Access the starting page of the web interface by entering the factory preset IP address 192 168 1 200 in the web browser Ir T Baudisch SIP DoorModule vc 192 168 1 200 a LLL SI Google A Phone book C Settings VoIP C Settings Hardware C Updates Password Choose an option and login with the factory default password 1234 Baudisch SIP Door Module Manual Current doc 38 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 Baudisch 5 3 Phone book 5 3 1 Switchboard E Baudisch SIP DoorModule Switchboard Switchboard Name Number DTMF Code Incoming Outgoing Relay Group ID 116 Zentraltuf 1168 fi II2 HE z 4 Accept z Announcement Off Ef On ll None Save Reset Name A name for the call destination can be entered here Both fields below are reserved for expansions and remain blank Number Here is the entry for the phone number or the IP address IP entry with dots entered DTMF code In order to trigger the relay with the door opening function an additional code can be entered via a keypad at the remote site during the call Up to 4 digit codes can be entered Shorter codes must be left justified In
75. of this robust intercom The features are e Suitable for outdoor applications protection class IP65 toward the front poke through protection by using the Baudisch V4A front panel or another front with a similar hole profile e Rear mount module for example for mail box systems cabinets or other panels Suitable mounting frames are available e The voice connection occurs per VoiceOverlP VoIP over the installed Ethernet LAN either directly to a SIP capable phone via a SIP phone system or per internet over a SIP provider e Priority of voice from the control station which means dialog is possible even if there are loud noises in the intercom s environment e The calls are triggered through the external ring buttons which can be directly connected to the module The maximum number of call buttons is dependent of the chosen model and optional expansions The connection of a minimum of 4 call buttons and a central call button is possible by all models in the basic setup e Simple configuration via the built in web server which is pre installed in a required language version German English French Italian e Switch output for the door opening per DTMF dial or per UDP command e Emergency call logic Features such as redialing call forwarding to alternative destinations and call acceptance confirmation of the control station over DTMF e The electrical supply occurs over the LAN PoE Alternatively a power supply can be con
76. onal Accessories Each module has 15 connections for ring buttons and one connection for another diode matrix module An expansion to 76 ring buttons is possible with the central call button and the 5 x 15 connections of the individual modules When the fifth diode matrix module is connected the 4 direct call buttons of the DoorModule MAXI can no longer be used mie Information on how to connect the MatrixModule is found in chapter 4 2 2 Connecting the optional accessories and information about the entries in the call destination list in the following chapter Baudisch SIP_Door_Module_Manual_Current doc 40 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 5 3 3 1 Entries in the call destination lists In order to assign the ring buttons to the call destinations the call destination data must be entered in the following way The call destinations 1 15 of the first matrix module in table 1 The call destinations 16 30 of the second matrix module in table 2 The call destinations 31 45 of the third matrix module in table 3 The call destinations 46 60 of the fourth matrix module in table 4 Baudisch I The last 15 call destinations 61 75 of the fifth matrix module are entered in the phone directory of the direct call button Call Keys Z1 Z4 to GND see chapter 5 3 2 Call Keys Z1 Z4 to GND j L Baudisch SIP DoorModule Call Keys Matrix Modules Baudisch SIP_Door_
77. ons Option seulement pour des technicien experte Parameter TestOptions Address OxFF1 4081d Bit 021 gt Activation of the call button simulation for long term or load tests It simulates a keystroke according to the following parameters With the delivery is bit 020 deactivated The remaining 7 bits are not used Parameter SwitchPattern Address OxFF2 4082d Bit pattern with which the buttons are set to be simulated Bit 0 SW EXT1 Bit 1 SW EXT2 Bit 2 SW_EXT3 Bit 3 SW_EXT4 Bit 4 UP Bit 5 DOWN Bit 6 OK Bit 7 no function Not all combinations can be used because the buttons UP DOWN and OK only individually make sense and the other 4 buttons only as a bit combination If all bits are set to O is no button pressed Module_Manual_Current doc 79 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch I The value of the following 3 parameters must be between 1 and 255 Parameter SwitchOnTime Address OxFF3 4083d Time which should fit the bit pattern The time is gt Value x SwitchGranularity x 50ms Parameter SwitchPauseTime Address OxFF4 4084d Time expected between the strokes The time is gt Value x SwitchGranularity x 50ms Parameter SwitchGranularity Address OxFF5 4085d Unit of time for SwitchOnTime and SwitchPauseTime 7 4 1 4 Disconnect a call after remote relay Parameter RemoteCancelCall Address 0x0604 1540d
78. oorModule Version 1 9 As of 03 05 2012 El Baudisch 3 3 Baudisch SIP DoorModule ECO MAXI in comparison SIP SIP DoorModule DoorModule MAXI ECO s Ethernet over RJ45 PoE IEEE 802 3af device power class 0 Screw type terminal for optional 24V supply PoE power supply over midspan or endspan Connection for 1 central call button Connections for 4 direct call buttons Light output for the central call button 1 switch relay door opener 1 switch relay light EasyLan Internal switch for CP CAM expansion Expandable for matrix and keypad module B cg AM C PE pp Z E Baudisch SIP Door Module Manual Current doc 11 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El 3 4 Scope of delivery Baudisch Artikel Name Baudisch SIP T rmodul MAXI ohne Frontplatte Komplettger t ohne Frontplatte mit Geh use mit Switch EasyLan T rrelais Lichtrelais Erweiterungsanschluss Baudisch SIP T rmodul MAXI ohne Frontplatte Complete functional unit without front panel with housing with switch EasyLan door relay lig i Baudisch SIP T rmodul ECO ohne Frontplatte Complete functional unit without front panel with housing without switch EthernetOut door relay Baudisch SIP Door Module Manual Current doc 12 99 Baudisch SIP T rmodul ECO ohne Frontplatte Komplettger t ohne Frontplatte mit Geh use ohne Switch EthernetOut
79. oot loader modus started Version 0 1 1 0 From Version 1 1 f r 4 polige Stiftleiste i Description Jumper Bridge on pin on strip from Pin 1t04 save DSP gt save mode J4 Pin 2 to 4 store factory gt saves the current VoIP and hardware settings as factory settings Pin 3 to 4 boot gt forces boot loader modus Baudisch SIP Door Module Manual Current doc 90 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 7 8 IP Video integration with Baudisch CP CAM Steel 7 8 1 Video display in the web browser The video data of the Baudisch CP CAM can be accessed directly over the IP network independent of a call or the SIP server That is a big advantage Without additional components the video color images can be viewed at several locations in the network also simultaneously via the web browser Only the execution of a Java plug ins is free A protected access with a password protects as needed the camera images against unauthorized viewing If the user network possesses an appropriately configured router is a global access of the camera images possible 7 8 2 Baudisch SIP VideoClient Alternatively to the video images in a web browser this software allows the automatic display pop up of the door video images on the screen The called PC workstation displays immediately the image with the applicable Baudisch IP camera this saves the user the manual start
80. ouncement message e g a message about the location of the intercom which the called person hears can be created and loaded into the intercom However the audio template must be in the appropriate form raw format to G711 u Law and then converted to the loadable flash binary format For this purpose the company Baudisch Electronic GimbH provides an appropriate tool upon request The tool inserts a 2 second silence at the beginning of the audio stream which is required as a forerun In addition the audio stream is set in a predetermined frequency range and converted into the right format You need the following files iP mkSipSnd exe conversion tool 2 Audio stream in wav format for announcement and ring tone The audio stream for an announcement may not be longer than 12 seconds and for a ring tone the maximum length is 22 seconds To convert the audio stream do the following 1 The tool mkSipSnd exe and the audio stream must be saved in a shared folder 2 Start the command line lt Start gt Execute cmd lt Return gt 3 Enter the path in the command line where audio stream and tool are saved 4 Enter the following command in the command line and confirm it with return mkSipSnd Name Audiostream wav lt Name Audiostream gt dat Example mkSipSnd Announcement wav Announcement dat 5 A Dat file should be added in the folder where tool and audio stream are saved The Dat file can be loaded as ring tone or annou
81. port 8113 Open CMD senden uei ez A vio vio vio vio v Unlock Ausschalten m jt Code DTMF Zentralruf Sendedaten Empfangen Absender Staus 1 Parameter BCC seq x Dd vcn Diei Program beenden 5 Make the following settings in the SIP Remote Control Destination address Destination of the data package The IP address of the SIP door module which parameters are to be changed must be entered here Input port 8112 UDP port for incoming data The setting must match the port for the status messages in the configuration of the SIP door module Output port 8113 UDP port for outgoing data The setting must match the port for the remote control in the configuration of the SIP DoorModule I The specified ports are not to be blocked by a firewall on your computer otherwise the SIP remote control cannot establish a connection with the DoorModule e Unlock Enter the unlock code Setup case sensitive The basic functions include the remote control of the relay and the camera IOs as well as the possibility to restart the DoorModule By entering Setup the boot loader function is activated Code DTMF Central call This setting must match the code setting for the central call at the intercom Baudisch SIP Door Module Manual Current doc 86 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 6
82. r switch function The contact number is used to address switching modules that have a shared address Default value is 0 Parameters Time for switch function 0 OFF 1 always ON 2 255 switch time in seconds mn The time parameter is only active in case of linked to a door opener relay If linked up to Remote or CAM IO the value sent via remote protocol is in use zei At the link up options only one option can be active for the same time In other case different time parameters will collide and there will be sent a command for each link up 7 4 1 8 Mask for keypad keypad functions Parameter Address 0x0614 1556 decimal Value Ox3E all functions active except send DTMF Bit 0 no function Bit 1 2 every number possible to dial activated Bit 2 code entry for door opener active Bit 3 Central call activated Bit 4 Speed dial activated Bit 5 Setting for dial timeout activated Bit 6 Only 4 digit codes allowed Bit 7 Send DTMF while calling activated I A restart is necessary after changing a value Baudisch SIP_Door_Module_Manual_Current doc 82 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 7 4 1 9 Alternative numeration of speed dial keys keypad Parameter Address 0x0615 1557 decimal Value 0 standard numeration BitO alternative order activated Bit 1 7 no function Standard numeration 00 gt Call entry 001 01 gt Call entr
83. rd the front for outdoor applications with protection against splash water Poke through protection by using the Baudisch V4A panel Weight without Baudisch VA4 panel ca 320 g with Baudisch VA4 panel ca 460 g Protection class IP65 in conjunction with a suitable housing Configuration operating display Integrated web server for configuration of all operating parameters and its internal phone directory per network via a web browser Illuminating diodes In the MAXI version 6 LEDs indicating device status In the ECO version 5 LEDs Baudisch SIP Door Module Manual Current doc 62 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch Miscellaneous Network switch REALTEK RTL8305SC Ethernet 10Base T and 100Base TX Half duplex full duplex Auto negotiation SIP RFC 2833 DTMF RFC2976 SIP info Protocols SIP over 10 100 Mbit LAN IP V4 TCP RTP DHCP UDP HTTP TFTP EasyLan VLAN IEEE 802 1pq Audio Built in speaker RL 8 Ohm 1W Typ power output 1 36 W with RL 8 Ohm Typ power output 22 22 W with RL 4 Ohm Typ power output 22 45 W with RL 3 Ohm Built in hands free microphone Jitter buffer Used audio codecs PCMU PCMA Speex iLBC G 726 32 GSM 6 10 Baudisch SIP Door Module Manual Current doc 63 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 Baudisch 6 2 Technical drawings 6 2 1 Baudisch SIP DoorModule MAXI ECO
84. remote control is the preset pulse duration relevant Door opening signaling The door opening signaling operates with the same principle as a blind traffic light A tone signal is heard as long as the door opener is pressed It can for example be useful by the application of a direct current voltage opener because there is no electro acoustics carried out Length of ID announcement Here the length of the recorded announcement must be set Extensionport function The extension port serves the connection of external add on modules and intra company service purposes An external add on module could for example be a switch component which makes it possible to connect up to 115 ring buttons at the intercom Keypad option This choice must be made when you would like to expand the door module with a keypad or matrix modules I The keypad option has no function by the DoorModule ECO version Baudisch SIP Door Module Manual Current doc 52 99 TE 03 05 2012 Baudisch SIP DoorModule Baudisch Version 1 9 As of 03 05 2012 5 5 3 Call Opt i BH Baudisch SIP DoorModule Call Opt Audio System Common Call Opt Status roe Max Call duration 0 endless 1min Or Jl 3 zl Timeout connection attempt 0 no timeout 1sec 3 I Redial attempts None Delay between redial attempts 1sec 30 zi Wait for acknowledge DTMF char for ACK Ho Call Keys Matrix Modules No Call to Switchb
85. rotocol are described in more detail in chapter 7 5 Status messages Remote Control The relays of the SIP DoorModule can be operated by remote control over the network when this function is activated By the DoorModule MAXI both camera IOs can additionally be controlled The remote control operates indeed by activated remote control however without activated status message no confirmation will be sent on a remote command SIP NOTIFY When a Baudisch CP CAM is connected to the DoorModule the image of the corresponding CAM can be shown by calls to a Snom 820 VoIP phone Therefore a separate file must be run which is located on the Baudisch CP CAM The path for the URL to the Snom XML file must be entered here Baudisch SIP Door Module Manual Current doc 56 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 Baudisch 5 6 Updates Updates can be imported for the firmware the ring tone and for the announcement i E Baudisch SIP DoorModule Update Upload Firmware C Ring Tone C Announcement C Factory S D Factory P Update File Start Upload Reboot Warning Update process must NOT be interrupted Note An update process may take a few minutes Please do NOT turn off the power The following file types are given Firmware xxxx bin Firmware file for the intercom Ring tone xxxx dat Sound file see chapter 7 1 AVR firmware update Announcement xxxx dat So
86. s and click on Advanced Advanced TCP IP Settings IP Settings DNS WINS Options IP addresses IP address 192 168 0 71 192 168 1 71 Subnet mask 255 255 255 0 255 255 255 0 Default gateways Edit Gateway 192 168 0 9 v Automatic metric Interface metric Metric Automatic E Cancel e click on Add by the IP addresses TCP IP Adresses IP Adresse Subnetzmaske 192 168 1 175 Baudisch Baudisch SIP Door Module Manual Current doc 20 99 TE 03 05 2012 Baudisch SIP DoorModule f enter the IP address 192 168 1 175 and sub net mask 255 255 255 0 Version 1 9 As of 03 05 2012 Baudisch e I An IP address from 192 168 1 1 to 192 168 1 254 can be chosen Only the IP address 192 168 1 200 is not to be used because it is used by the door module The address range is defined with these two entries which include the location of the PC laptop and its associated IP address g click on Add Advanced TCP IP Settings IP Settings DNS WINS Options IP addresses IP address Subnet mask 192 168 0 71 255 255 255 0 192 168 1 71 255 255 255 0 2 168 1 175 255 255 255 0 Default gateways Gateway Metric 192 168 0 9 Automatic Automatic metric nterface metric e I now the entered IP address and subnet mask are shown in the table Baudisch SIP Door Module Manual Current doc 21 99 TE 03 05 2012 Baudisch SIP DoorModule
87. s of 03 05 2012 Baudisch e Unlock Enter the unlock code Update case sensitive The basic functions include the remote control of the relay and the camera IOs as well as the possibility to restart the DoorModule By entering Update the boot loader function is activated e Code DTMF central call This setting must match the code setting for the central call at the intercom 6 Press the button Open I A connection is established when the data is shown in the following form in the window Received The screen is similar to the example r Empfangen Status Parameter scc seg 192 168 1 200 OxDA System idle YSFO V1 8 v2 6 Esi OxDS 0x25 7 By pressing the button Bootloader the following window opens up Bootloader SB Firmwaredatei Firmware schreiben EEPROM Datei EEPROM schreiben Status Wait For Selection Progress Info Info Detail SchlieBen 8 Enter the path of the file xxx hex in the firmware file which you have received as an e mail attachment 9 Make a check at Firmware schreiben 10 By pressing Start the firmware is installed The process may take longer and is complete when Operation successful is shown in the status field Deactivate state and remote control in web interface I Reset the status and remote control in the web interface to off You have successfully completed the update of the AVR
88. se 32 inputs of the module 7 2 4 Configuration Baudisch SIP DoorModule MAXI for EasyLan Start the configuration menu see chapter 5 2 Start of the configuration menu Hardware settings gt System e Set the function expansionport to EasyLan 4 800 Bps 8E2 Baudisch SIP Door Module Manual Current doc 77 99 TE 03 05 2012 Baudisch SIP DoorModule 7 3 mm mm m 7 4 Version 1 9 As of 03 05 2012 E Baudisch Chain operation The chain operation function is only possible with the Baudisch SIP DoorModule MAXI version because it has an integrated switch which provides a corresponding connection This type of series connection with the Baudisch SIP DoorModule MAXI is designed for use in tunnels The chain operation is connected to a separate operating voltage of 24 V on the specified terminals see chapter 6 3 How to connect for each individual module Except for the last module in the chain the camera IOs of the previous modules are not to be activated Chain operation network cable RJ45 E Ethernet Ub ov wall plug wall plug wall plug transformer transformer transformer 24V 24V 24V Special functions Different parameters in the EEPROM Register can be read and overwritten via UDP Due to the change special functions can be activated and configured which are not accessible over the web interface Attention Updating the AVR firmware may reset all settings
89. supply class 1 endspan only by connection over a data line 24V connection instead of PoE over unused wires on the network line possible I The front panel is not included in the delivery of the Baudisch CP CAM Steel and must be ordered separately Baudisch SIP_Door_Module_Manual_Current doc 14 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch Baudisch Central Call Individual button which can show 6 different modes of ButtonModule the door module using an integrated multi colored circle Art Nr 33 1144 light V4A front panel included Module for direct connection to the central call of the Baudisch SIP DoorModule MAXI or ECO V4A front panel with vandalism protected stainless steel button LED circle illumination Mode display M green gt ready red gt connection red NN ual red yore gt announcement rd gn gt incoming call green gt eerror e I The front panel is included in the delivery Button Modules with 2 or 3 buttons are available upon request Baudisch ButtonModule 4 buttons Button module with LED illumination Art Nr 33 1192 Module for direct connection to the SIP door module MAXI ECO The lettering is inserted from the rear with push in strips I au ae LED background illumination A A se Up to 4 ring buttons are connectable er e I Button Modules with 2 or 3 buttons are avai
90. t Nr 33 1127 series switching of 5 modules possible Module for the direct connection to the SIP DoorModule MAXI Open circuit board to be mounted in protected areas Each Diode MatrixModule allows connection of up to 15 call buttons Up to 5 Diode MatrixModules can be cascaded to the SIP DoorModule MAXI I The connection of the Baudisch Diode MatrixModule is only possible to the SIP DoorModule MAXI version 16 99 TE 03 05 2012 Baudisch SIP Door Module Manual Current doc Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch Baudisch system housing IP65 System housing for the installation of any 3 modules Art Nr 33 1123 Massive version to be used at factory buildings or on construction sites Wiring from below of the housing Material aluminum die casting Color Top section blue according to RAL 5002 Bottom section black powder coated I The V4A front panels are inserted into the frame Material aluminum Color light anodized powder coated on request Mounting of the module with rear bolting Deliverable frame sizes single 120x120x5 7mm gt Art Nr 27 0235A double 230x120x5 7mm gt Art Nr 27 0235B triple 340x120x5 7mm gt Art Nr 27 0235C quadruple 450x120x5 7mm gt Art Nr 27 0235D I The built in modules shown in the picture are not included in the delivery Baudisch SIP Door Module Manual Current doc 17 99 TE 03 05 2012
91. t Be beoe ice t edet Bec e Ede o E En ud 9 3 1 General e fe Tine rcu o err nahe bannen ehe han een 9 3 2 OVEIVIOW si cae 10 3 3 Baudisch SIP DoorModule ECO MAXI in comparison 2 224044440nnnnnnnnnnnnnnnnnnnnnnnnnnn nn 11 3 4 Nfeeje Nee ul EE 12 3 5 Optional Accessories een eer hails Lake id eel 14 4 Starting UB irren 19 4 1 i ivennireiim e 19 4 2 ence m M 25 4 2 1 Baudisch SIP DoorModule connection sssssssssssssee ener 25 4 2 2 Connecting the optional accessories eene nnne nnns 26 4 2 3 Connecting a keypad module sssssssssssssseseeeseeeneee nennen nnne tenter sinn sn nennen nns 29 4 2 3 1 HOW tO COMME een ankamen nenne dees 30 4 2 3 2 BI E ET 32 42 3 3 Code entry terne oe tetti e Poeta end nn bue k odo aad cues vacdedabacedcugeaacedcdesdecuadebaens 34 42 3 4 Central call 5 5 iiie taria enden anne anne Ahnen ahnen 35 4 2 39 5 Speed dialing 5 rrt ent es repe ln 35 4 2 3 6 Configuration of the keypad parameters sssssssssssseeeeeeen nenne 36 4 2 3 7 Tone signals uin Fecerat nenn 37 42 3 8 Ending a call ettet tenter e era aa eC aa Ee RR aeaa 37 5 Use and configurat Messenien enea ia E naia ARA e E ES Eiaa ii 38 5 1 Starting requirements ea lei 38 5 2 Start o
92. t an intercom and the last time block is beyond 60 minutes The code entry is therefore blocked for 3 minutes When the code is once again 4 times incorrectly entered after the 3 minute time block the new time block lasts for 5 minutes When the code is once again 4 times incorrectly entered after the 5 minute time block the new time block now lasts for 10 minutes and so on There is no longer time block than 20 minutes Baudisch SIP Door Module Manual Current doc 34 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 4 2 3 4 Central call e I This function is not available with a 3x4 KeypadModule By pressing the yellow i button at the 4x4 direct call module the central call is dialed which has been set up in the phone book To end a call press the green receiver button 4 2 3 5 Speed dialing I This function is not available with a 3x4 KeypadModule Speed dial numbers The speed dial numbers corresponds with the assigned numbers from 00 59 in the phone directory The following table shows the assignments Speed dial number Configuration menu gt Contact corresponding Phone book rows 00 14 Call button via matrix module 1 15 table block 1 15 29 Call button via matrix module 16 30 table block 2 30 44 Call button via matrix module 31 45 table block 3 45 59 Call button via matrix module 46 60 table block 4 60 99 Phone book block 61 100 En
93. te see chapter 5 5 4 Status Remote 7 5 1 Protocol A UDP data package is structured as follows Sequence number gt lt Status gt lt Parameter bytes Proof total gt Sequence number Number of the current data batch Is always increased by 1 until 255 is reached and then restarts at 0 This allows the recognition of multiple reception of a data batch The sequence number consists of a 2 byte HEX string example 01 FF Status Specifies the current status or type of the data message The status consists of a 2 byte Hex string Parameter bytes The parameter bytes complement the status bytes They contain detailed information about the status bytes for example a phone number status refinement etc The parameter always consists of 24 characters ASCII no functional characters Unused spaces are filled with blanks Proof total The proof total is used to check if the data package contains correct status data A transmission backup is done over the Ethernet transmission layer CRC32 The proof total consists of a 2 byte HEX string and is made up of all data bytes as Addition Modulo 256 7 5 2 Messages Status byte Parameter bytes Description 0x0A blank or XY Idle mode IDLE XY Firmware version ATmega 2 digits HEX 0x01 Number of the caller Incoming call 0x05 Number of the remote Connection status station 0x06 lt blank gt Status to dial 0x07 Number of the remote Dialing status stat
94. try at the 4x4 KeypadModule e I To cancel a speed dial call and end an ongoing call press the green receiver button Baudisch SIP Door Module Manual Current doc 35 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 4 2 3 6 Configuration of the keypad parameters I First the configuration selection must be started in order to configure the keypad parameters Activation of the configuration selection To activate this mode the following button combination must be pressed e Press and hold the key 0 Now press the green receiver button gt n addition to the error tone a button confirmation follows Then release the buttons kie e Press and 1 simultaneously gt A confirmation follows as well Then release the buttons e Press and 2 simultaneously gt A short continuous tone follows as confirmation e Now you are in the selection of the configuration options There is a time limit by all the steps It switches to idle mode after 10 seconds of no further entry Configuration of the keypad parameters Setting of timeout for number entry e Press the key and 1 simultaneously in the configuration selection A confirmation follows e Two digits must be entered just like the speed dialing Values in the range 01 to 10 one to ten seconds can be entered To large values are limited to 10 seconds and 00 is corrected to 01
95. ule Manual Current doc 58 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 El Baudisch 5 7 Reset to factory settings The device can be reset to factory settings when the setting of the IP address or the access password is unknown mni From version 1 1 the reset is done with a small switch see side view of the door module In older versions a connection at jumper J3 must be established on the bottom circuit board see top view of audio circuit board on the next page mi When loading the factory settings all VoIP and hardware settings are reset The entries in the phone directory are not affected The preset network settings are IP address 192 168 1 200 Sub net mask 255 255 255 0 Password 1234 Reset to factory settings from version 1 1 1 Turn off the power e When supply over PoE unplug the network connector at X1 INPUT see chapter 6 3 How to connect e When supply over an external power supply remove the connection Ub at the terminal X3 X4 Side view of the DoorModule 2 Turn the switch J3 to LF load factory 3 Connect power 4 Wait until the booting process and the following automatic sequence are completed e Confirmation tone and LED 1 2 red yellow are lit e LED2 red is lit e LED 1 green is blinking 5 Switch J3 to OFF The door module is automatically restarting The resetting to factory settings is completed Baudisch SIP Door Module
96. und file see chapter 7 1 AVR firmware update Factory setting S Upload for setup data Factory setting P Upload from phone directory data The corresponding update files are available from Baudisch or the files can be generated on your own according to the instructions manual for the ring tone or the announcement Baudisch SIP Door Module Manual Current doc 57 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of 03 05 2012 E Baudisch 5 6 1 Firmware The software of the SIP DoorModule can be updated by updating the firmware I The update is available from Baudisch on request Send us an e mail with the product names and serial numbers We need this information in order to send you the applicable firmware In case you do not have the serial numbers indicate the date of purchase E mail update baudisch de I To keep the functions of the DoorModule warranted an update of the AVR firmware should follow an update of the firmware see chapter 7 1 AVR firmware update To perform an update of the firmware 1 Start the configuration menu see chapter 7 1 AVR firmware update 2 Choose updates enter password and login 3 Choose firmware File to be transferred enter the path where the file xxx bin from us is located Start the transfer and wait until the automatic reset of the module which is performed after an update is completed 2 min You have successfully updated the firmware Baudisch SIP Door Mod
97. y 002 99 gt Call entry 100 Alternative numeration 01 gt Call entry 001 99 gt Call entry 099 00 gt Call entry 100 e I A restart is necessary after changing a value 7 4 1 10 Time lock between call cancel and further dial Parameter Address 0x0616 1558 decimal Value 0 no time lock The lock time is defined by the chosen value x 50ms Value 20 effects in a lock time of 1 second 1000ms e I A restart is necessary after changing a value e I Value 0 effects a lock duration for about 500 800ms There are systems that can t handle a fast following change between new calls and ended calls So these parameters allow to increase the duration 7 4 1 11 Offset for door opener code for selection relay DTMF amp keypad address function value range hexadecimal decimal 0x0617 1559 Offset for first digit of the 0 9 F code 0x0618 1560 Offset for second digit of 0 9 F the code 0x0619 1561 Offset for third digit of the 0 9 F code 0x061A 1562 Offset for forth digit of the 0 9 F code Valid offsets are 0 to 9 Unused digits must be F 0x46 If there is one or all invalid value the offset function is disabled e g value OXFF and accordingly 255 The code of the second relay is the sum of the offset and the configured door code Baudisch SIP Door Module Manual Current doc 83 99 TE 03 05 2012 Baudisch SIP DoorModule Version 1 9 As of

Download Pdf Manuals