1. LEAS Le travail dans urn esprit de confiance CityShark II Short Form User s Manual V808 2008 June 24th 1 Adjustment of the recording parameters To start recording push the yellow button then the blue button by keeping the yellow button pressed To change the current parameter to another push the yellow button The cursor flicks on the parameter To change the parameter s value push the blue button To have a fast run of the values keep the blue button pressed Clock Setting Month 07 Day 09 Hour 14 Minut 12 First screen of parameter setting GPS Receiver On This screen offers the possibility to set date month day and time hour minute of starting The parameter GPS receiver activates the GPS ON OFF To validate these parameters push the green button Start recording GPS update Inputs nb 18 Batt low level Batt voltage Second screen of parameter setting The parameter GPS update allows the update of date and time of the station by GPS for better synchronisation let GP On and Update Yes even though no GPS reception The next parameter set the number of inputs used Inputs nb Thi number doesn t be higher than channel number really running Batt low level sets the level of detection for alarn battery Batt voltage allows a forward reading of the battery voltage Read only Below 11V the internal battery could fai irreversibly In order to validate
2. NextFil name of the next file which is automatically updated with the time Lgth duration of recording Rep rate of repetition of recordings If zero no repetition If CONTINUOUS continuous mode is activated Amp nn level of the signal which is represented by black square on the screen as a bargraph nn means the numbers of real channels Stop in progress of the recording phase push the green button Start recording during approximately 5 seconds The file in progress of recording can be saved or not by the user only if the duration file is longer than one minute If the file in progress of recording is erased its index is saved for the next recording 3 File encoded ASCII after the loading by ReadCity from the card flash Original file name 01301530 011 Name of the original file Transformed into 080130 1530 011 Name of the file extracted by ReadCity ReadCity version 3 3 Version of the extracting software Station serial number 045 Serial number of the station Station software version 0805 Version of the software on the station Channel number 18 Number of recording channels 18 max Starting date 30 01 2008 Starting date of the recording phase Starting Tames 15212301327059 Starting time of the recording phase Ending date 30 01 2008 Ending of the recording phase Ending time 15 31 52 849 Ending time of the recording phase Sample rate 100 Hz Sample rate Sample number 6000 Number of samples d
3. these parameters push the green button Start recording Gain 8192 Ovmx 5 Lgth 12mn Rep Oh Sample Rate 100 Hz File Index 001 Third screen of parameter setting This screen sets the values of the amplification Gain the maximum rate of saturated samples Ovmx the recording time Leth the period of automatic repetition of recording sequence Rep or continuous mode the sample rate and the index of the first file File Index In order to validate these parameters push the green button Start recording About these parameters only the gain can be modified with yellow or blue buttons within each recording without to come back in this screen The going beyond rate Ovmx is indicated by a beep Hence it s in charge of user to decide to stop or not the current recording 2 Recording Set the gain with the yellow and blue button respectively Gain up et Gain down Start recording by pushing the green button Start recording The corresponding light flicks during recording phase The end of the recording is indicated by three series of three beeps Hence the following information is shown on the screen 1st screen then Now recording Gain 8192 Ovf 3 01 18 channels NextFil 07071424 002 at Lgth 12mn Rep Oh 100 Hz Amp 18 w eeueuuw Gain current gain 1 2 4 8 16 32 64 128 256 512 1024 2048 4096 8192 Ovuf rate of saturated samples from the recording in progress
4. h a 4 amps fuse The condition of charge should never exceed 13 8 Volts 500mA The external power supply is protected with a 2 amp fuse This voltage should never exceed 13 Volts Sensors A Ze SP F E Base plate Souriau 851 F 85102E1210S50 B Z G 12 Volts 10mA PLUG 3 Souriau 851 M 85106EC1210P50 C N H Not connected D N J Shielding Internally connected to 0 Volt E E K 0 Volt LEAS 175 all e de Champrond F38330 SAINT ISMIER 334 76 52 13 30 www leas fr js leas fr
5. uration sample rate Recording duration 1 mn Recording duration Conversion factor 52428 8 Number of bits by volt with a unit gain Gain 16 Gain Dynamic range 5 V Dynamic range 5V 2 5V 10V 5V Clipped samples 2 83 Saturating rate Latitude 45 14 629 N GPS Data Longit de 5 AG e25 E GPS Data Altitude 314 m GPS Data No Satellites 5 GPS Data Maximum amplitude 116997 131072 Max level stored Max dynamic available 116997 42510 13830 Data sample 1 printed in digital points 114787 41050 11783 Data sample 2 printed in digital points These data are presented in the order ZNE separated with lt TAB gt Refer to the using CDRom for the extraction phase of data ReadCity The maximum dynamic is automatically limited following a dynamic reduction table relating to the sample freque ncy The conversion factor CF is the result of CF 2 max dynamic available Dynamic range Ex 100 Hz amp 5V of Dynamic ranges the Conversion Factor CF 2191972 5 52428 8 bits V Given at gain 1 To get the electric level at the input of CityShark II Vin Data CF Gain Ex Data 116997 Gain 16 CF 52428 8 Vin 116997 52428 8 16 139 471 mV 4 Wiring of the CityShark II s catchs Power Supplies A 0 Volt Base plate Souriau 851 F 85102E123S50 B Charge Battery Pltiic 4 So rian B51 M SS lLO0GECL2Z3P50 C Extern Battery 12 Volts The charge of the battery is protected wit