image

Contents

1. EMA www ema es ATTENTION CORRECT USE CLEANING WARNINGS FORA CORRECT USE OF THE DEVICE iF The sauna blanket MN 8000 CAN NEVER BE FOLDED when functioning or when it s warm Do not ever fold the sweating blanket and do not ever put weight on top of it no matter if it is functioning or not in order to avoid short c ircuits and imeparable damages When the blanket is functioning venfy if the intenor pannels of the bag are correctly extended without folds Also verify whether the blanket is correctly positionned on the bed avoiding the blanket getting punched by the movable partsofthe bed If you like the blanket to sta y lukewarm and ready for the next treatment you can leave the device tumed on following the next instructions 1 Make sure the MN 8000 is well spread on the surface of the bed Itcan not be folded anywhere 2 Make sure the temperature of the three areas has been programmed at Minimum Level Level 1 only one cursor programmed Y see Functioning Programming the level of potency Before doing any cleaning or maintenance put the temperature control at zero and disconnect the device from the general power network In orderto guarantee a maximum efficiency and durability of your heating blanket it is necessary to be as carefull as possible when cleaning it Use a moist cloth with diluted alcohol to take out stains DO NOT USE DETERGENTS OR CHEMICAL PRO DUCTS We suggest you wrap your clie
2. WwwWw ema eS User s Manual for performing treatments MIN 3000 How to make your device work MN 3000 User s Manual for performing treatments WWwW ema es GENERAL INSTRUCTIONS BEFORE USING THE DEVICE READ THE INSTRUCTIONS When the device is working qualified personnel needsto be ATTENTIVELY KEEP THE MANUAL FOR FUTURE CONSULTING present at alltime THE MN 8000 forms a professional heating method for sweat therapy This device hasto be used exclusively for what it has been designed for When you receive the merchandise please verify whether tt has suffered damage and whether all the components are complete and in good conditions Before any doubt do not use the device and venty if the damage may be caused by an incorrect manipulation during transport Should this be the case contact the distnbutor within 24 hours after reception in order to be able to hold the transport agency responsible forthe quality of the product Before connecting the device verify whether all the data printed on the device s label correspond to the characteristics of the electric network lt is not possible to change the input tension of the device If the tension is not correct contact your distnbutor and do not try to connect the device EMA www ema es MN 3000 User s Manual for performing treatments TECHNICAL CHARACTERISTICS MN 8000 is composed by eA central command device contro
3. following connection between Po ee the different parts of the device Put the MN 8000 on the bed asdescnbed in Fig 1 LJ qa o Connect the 3 body thermoheating subsections 9 to the working console Push the START button 1 one time After approx 3 Connect the input cable to the working console 11 minutes the device will enter in state of MAINTENANCE and the socket minimum potency only one cursor programmed After performing these operations the sauna bag MN 8000 Is ready for use PROGRAMA 1 JS TIMER 00 00 TOA N B The state of MAINTENANCE is indicated by the following figure which will appear on the first line instead of the figure S _ EMA MN 8000 Www ema es User s Manual for performing treatments INSTALLATION PREFUNCTIONING NB During this phase the temperature reaches 30 C and this NOTES temperature will be maintained all day long The system allows you to always have an activated device at your disposal so you can start a new treatment at any moment During maintenance the energy use decreases from an average of 100W during the treatment phase to a mere 18W per thernoheating subsection thusly saving energy EMA www ema es MN 3000 User s Manual for performing treatments FUNCTIONING 1 Program selection The device allowsto choose between 10 programs between O and 9 These programs can be freely reconfigurated in treatment duration a
4. 0 User s Manual for performing treatments WWwW ema es GET INFORMED ABOUT OUR NOVELTIES WE ARE ALWAYS AT OUR CLIENTS SERVICE AND WE WILL ALWAYS TRY TO HELP YOU 1 BEFORE ANY DOUBT PLEASE CONTACT US NO MATTER IF IT S A TECHNICAL QUESTION REGARDING THE USE OF THE DEVICE OR ANY OTHER QUESTION ABOUT HOW TO PERFORM TREATMENTS 2 WE CONSTANTLY OFFER FORMATION AT OUR PREMISES AND WE CAN HELP YOU AMPLIFY YOUR KNOWLEDGE AND WE CAN HELP YOU TO DOMINATE THE TREATMENT TECHNIQUES WITH EASE ASK ABOUT OUR FORMATION CALENDAR EMA Bioinside Investigacion y Tecnologia S L Poligono Industrial Fontsanta Sant Mart de l Erm 22 Tel 902 31 51 71 08970 Sant Joan Desp l Barcelona Espa a info ema es
5. ENANCE level equivalent to the first level Visualisatio n modific ation interruption of the teatment During the treatment it is possible to VISUALISE the previously made programming by pressing one of the buttons H 3 4 If you need to MODIFY THE PARAMETERS temperature time press the STOP button 2 On the first line of the display an exclamation mark will appear instead of the treatment icon M Modify the temperature with the button 3 4 and the time with the button 6 7 In order to restart the treatment press the START button 1 EMA www ema es MN 3000 User s Manual for performing treatments INDICATIONS If on the contrary you wish to DEFINITELY INTERRUPT the treatment you only need to press the CLEAR button 8 The treatment icons will automatically disappear the timer will set to zero and the device will enter into the MAINTENANCE mode Alam signal The device can detect any kind of enor in the treatment sections whether it sa stop a short circuit ora lack of input If any of these problems occur an acoustic alarm will be activated in order to report the problem and on the display an alam screen will pull up indicating the defectuous themosection ALARMA SECCION AVERIADA In order to leave the alam screen press the CLEAR button 8 When the main menu shows up again it is already possible to replace the defectuous subsection press the button to decrease the tempe
6. ainng the device e Do not ever immerse the device in water In case something liquid accidentally penetrates the device do not tum on the device and immediately contact the technical department elt is forbidden to remove the label situated on the cover indicating the seral number Failure to observe this instruction will automatically nullify the warranty eAt the end of the working day please venfy whether the device has been switched off OFF and whether the network cable has been disconnected from the electricity network e Take into account that the perception of warmth may vary in function of the body constants This means the perception of wa mth will differ whether it is winter or summer eWe recommend using a voltage regulator in order to assure a cormect and constant electrical current supply EMA MN 8000 User s Manual www ema es p for performing treatments REPLACEMENT OF THE REMOVABLE SUBSECTIONS In case of replacement of the removable subsections of the a MN 8000 we hereby explain the procedure to follow 5 Slip the input cable in the defectuous subsection in the bag sintenor through the lining in A Y O O 6 Remove the heating subsection that needsto be replaced Disconnect the three plugs from the current supply Spread out the MN 8000 on a flat surface as indicated in Figure 2 Looking atthe MN 8000 you will see the three outlet holes of the input cable Input cable with commut
7. ator EMA www ema es MN 3000 User s Manual for performing treatments REPLACEMENT OF THE REMOVABLE SUBSECTIONS 7 Take the new heating subsection and position it as shown in Figure 4 When looking at the blanket you must see the outlet of the input cable and the labels 8 Insert the subsection with the input cabling dangling out of the lining IMPORTANT MAKE SURE THE SUBSECTIO N IS FOLDED OUT WELL INSIDE THE BAG UNDER NO CIRCUMSTANCES THE SUBSEC TIO N SHO ULD BE FOLDED 9 Close the back with the corresponding button and tum the MN 8000 around so it can be used EMA www ema es MN 3000 User s Manual for performing treatments WARRANTY The warranty is valid during a period of two years starting from the date of purchase and applies to the product and all of its components The purchase date on the invoice bill counts as starting date The warranty covers the free of charge repair of all damaged parts or defects pre existing to the purchase date of the sauna blanket The waranty does not cover elmegulanties in the functioning or defects derived from an incorrect electncal installation eDetenorations or damages produced as the consequence of an installation differing from the one indicated in the present instruction manual Defects derived from the fact that the product has been used with or has been connected to accessones different from the ones subministrated by the manufact
8. icante Manufacturers address Adresse du fabricant Deciara que el producio Declares that the product D clare que le produit Nombre dei producto Name of the product Nom du prochut Marca Brand Marque Cumple con la nomativa Complies with he norn Est conforme la norme Electroest tica amp MAnhilirvin MAR ZO 2005 MARCH 2005 MARS 2005 BIOINSIDE INVESTIGACI N Y TECNOLOG A S L Sant Marti de i Erm 22 E 08970 Sant Joan Despi BARCELONA SPAIN Electrocosm tico Elec rocosm etic Electro cosm tique MIN 8000 EN 55014 1994 EN 55104 1995 EN 61000 3 2 1995 EN 61000 3 3 1995 CEI 62 39 1992 Y porlo tanto responde a los requisitos esenciales de la Directiva And therefore cumplies with the essencial requirements of the Directive Et ce pour quoi accomplit les conditions essentiels de la Directive DIRECTIVA 89 336 CEE Compatibilidad Electromagn tica DIRECTIVA 73 23 CEE Baja tensi n Seguridad el c trica Manufacturer s suggestion We value your opinion Please send us your comments and suggestions so we can offer you a better service You can contact us by sending your letters to the following address Bioinside Investigaci n y Tecnologia S L Sant Mart de l Erm 22 Pol gono Industrial Fontsanta 08970 Sant Joan Desp Barcelona Espa a National tel 93 477 42 62 International tel 34 93 477 42 63 E mail info ema es MN 300
9. ion for those persons with a heat tolerance lower than the temperatures obtained with programs 4and 5 Program 7 is a long INTENSE SWEATING program concentrating the action of the extemal temperature inthe ABDOMEN and CHESTareas Program 8 is a short INTENSE SWEATING programme concentrating the action of the extemal temperature onthe ABDOMEN and BUST area Programme 9 is a long MODERATE SWEATING programme for those persons with problems in the ABDOMEN and the THIG HS Programme 0 is short MODERATE SWEATING programme for those persons with aesthetic problems concentrated in the ABDOMEN that is in program 1 approx 302C Thanks to this system your device is always ready fora new treatment User s Manual for performing treatments Once the programmed time hascome to an end MN 8000 does MN 8000 EMA D not shut down it automatically enters in the MAINTENANCE phase www ema es Temperature tested with an environmental temperature of approx 202C a Treatment Graphic indication of the temperature in each subsection Inferior middle and superior part FULL BODY 3 Short Light ABDO MEN CHEST 1 Long STAND BY 30 A E O MODE HOLD MAINTENANCE CORPORAL TONNIFYING 1 CORPORAL TONNIFYING 2 CORPORAL 582 FULL BODY 1 Long 582 FULL BODY 2 Short 7 2 2 ABDOMEN CHEST 2 Short ABDO MEN LEGS o o Q Q Q Q Q ABDOMEN MN 3000 User s Manual for performing treatments
10. l unit A bag divided into three independent areas e 3 intemal sections with removable thermo heating parts One input cable eA cushion forthe client s comfort Optional e Facial mask forthermoheating e Primary input 230V e Secondary input 24V e50 Hz e Altemating current eClassIl device Bag divided into three independent areas Matenal 25 polyesther 25 expansion 50 polyuretha ne vinyl Size Closed approx 2 000 x 700 mm Opened approx 2 000 x 1 600 m DIRECTIVAS BAJA TENSI N Y EMC Removable thermoheating blanket 24V Matenal Intenor 100 polyesther Exterior 100 vinyl Size approx 1 500 x 580 mm 24 V 50 Hz 100 W Continuous regulation through a sensor inserted into the resistance This product has been manufactured conform the EC standards 89 336 CEE Hectromagnetical compatbility 73 23 CEE Low tension electrical sec urity MN 8000 www ema es User s Manual for performing treatments CONTROL UNIT DESCRIPTION OF THE COMMANDS FRONTAL Sta rt Sto p Increasing temperature in the indicated body areas 1 Lower legs 2 Hips and abdomen 3 Chest Decreasing temperature in the indicated body areas 1 Lower legs 2 Hipsand abdomen 3 Chest Selection of the programs offered by the device Increasing time minutes Decreasing time minutes Reset clear DESCRIPTION OF THE COMMANDS HINDSIGHT 9 Connectors for the corporal thermoheating section
11. ns 6 and 7 The timer can be programmed eating upto a maximum of 60 minutes gt Level 1 Minimum MAINTENANCE or WAITING MODE gt gt Level 2 PROGRAMA 2 gt P gt Level 3 gt gt P gt Level4 T 60 TIMER 00 00 gt gt gt gt gt Level 5 Maxim EMA www ema es FUNCTIONING 4 Sart the teatment Once all the parameters have been introduced the treatment can be started by pressing the start button 1 The timer indicating minutes and seconds will start counting back immediately showing the time left until the end of the treatment When the treatment time has come to an end an acoustic signal will wam the user that the treatment has finished MN 8000 will automatically disconnect retuming to the temperature maintenance mode prepared to start a new treatment PROGRAMA 2 jj T 60 TIMER 59 59 ce MN 3000 User s Manual for performing treatments INDICATIONS Indic ation of the temperature level during the treatment Thanks to the indications visible on the display the user is constantly being informed about the level of potency and consequently about the temperature in each sector The filled steady cursor MW indicates the desired level has been reached The empty blinking cursor indicates the programmed level of temperature isin processof being reached At the end of each session the device AUTOMATICALLY adopts a MAINT
12. nt in disposable plastic blankets before starting the treatment thusly assunng your client a maximum of hygene and your MN 8000 a larger durability MN 3000 User s Manual for performing treatments EMA www ema es ATTENTION IMPORTANT INFORMATION eThis device must be used exclusively as a professional beauty sauna blanket Any other use has to be considered inappropriate and consequently dangerous The manufacturer cannot be held responsible for possible damages inflicted upon persons animals or objects as a consequence of an inappropnate wrong or irrational use Do not open or do not force the device or its accessones For any repairs contact the technical service Failure to respect this wa ming may compromise the device s sec unty e Do not use the MN 8000 on ill persons or persons insensible to heat oron children e The working console will warm up because of the natural thermic dissipation of the components Avoid obstructing the ventilation of the device Do not ever touch the working console or the sockets with wet or moist hands Do not ever pul the network cable in order to disconnect the device from the plug e Never leave the device exposed to extreme environmental conditions rain sun Never introduce sharp objects such as needles files into the blanket Always take the electrical connection cable out of the power plug before assembling installing cleaning or rep
13. rature of the outlet until the score appears Press START 1 in orderto restart the treatment EMA www ema es n MN 3000 User s Manual for performing treatments PROGRAMS The MN 8000 programs allow for a more personalized and multiple selection of the treatment options They are detailed in the tabel below In this table have been included parameters such as treatment type duration time the temperature to be reached the symbol shown on the screen identifying the treatment etc Identification of the programs Program 1 is MAINTENANCE It is a transition program that allows to have your device ready for treatment all day long Program 2isa TONNIFYING corporal program RELAXATION with an average duration of 30 minutes dunng which it increasesthe body temperature in a pleasant way Program 3 is a TONNIFYING corporal treatment program RELAXATION with a short duration It is indicated as preparation before other electrostimulation treatments Program 4 isa long INTENSE SWEATING program for the entire body We recommend combining it with the use of lypolitic products like mud or algas since it helps to degrade the localized greases Program 5 is a short INTENSE SWEATING program forthe entire body We recommend its use for adiposities in specific areas It isthe reduced version of program 4 ideal for persons who only want 20 minutes of treatment Program 6 is a MODERATE SWEATING program of short durat
14. s interior middle and upper subsection 10 ON OFF Button 11 Network cable EMA 4 MN 8000 www ema es User s Manual for performing treatments MEANING OF THE SYMBOLS ON THE DISPLAY meL PosmonninG MEANING First line of the display ARRO W yl STAND BY First line of the display TWO ROWS OF SCORES MAINTENANCE The MN 8000 remainswam ata temperature of approx 308C First line of the display FIG URE OF A USER Body treatment initiated Last line of the display EXCLAMATION MARK Pause to modify the programmed time and temperature Last line of the display TRIANG LE Visualisation of the programmed temperature level Last line of the display BLINKING EMPTY RECTANGLE temperature level that is about to be reached Last line of the display STEADY FILLED RECTANGLE programmed temperature level has been reached Last line of the display SCORE The programmed temperature level is zero DOES NOT HEAT MN 3000 User s Manual for performing treatments k gt y amp N WWwWW ema es INSTALLATION PREFUNCTIONNING The installation must be performed according to the Start up the device by tuming the general switch to instructions detailed below An installation emor can postion ON 10 The following screen will pull up which cause damages to persons animals or objects for will help you program the device which the manufacturer can not be held responsible The installation requieres the
15. s well as temperature level The program selection can be started up by repeatedly pressing the PROG button 5 Once you have selected the appropnate treatment you can proceed to its personalization time and temperature as descnbed further on 2 Programming the potency level temperature Once you ve selected the appropnate programme it is Select possible to program the potency level the desired temperature level for each of the thermoheating subsections Min O Max 5 wit the help of the buttons Y 3 4 situated on the display Pressure these buttons and the cursors of the fourth line will disappear m and arrows will show up P Once the temperature level of each thermoheating subsection has been programmed the cursoss will automatically re appear m instead of the anows P The arrows indicate the programmed level of potency At any moment dunng the treatment it is possible to control the level of potency selected previously by simply pressing the buttons Y 3 4 It is possible to exclude one or more thermoheating subsections from the treatment by repeatedly pressing the corresponding buttons for decrease 4 until a score showsup EMA www ema es MN 3000 User s Manual for performing treatments FUNCTIONING Selectthe temperature level 3 Programming the Timer BODY The time can be programmed by pressing the time lcd of the non activated blanket without butto
16. urer together with the device or differents from the ones that have been officialy authorized eTheft falls extreme thermical or environmental conditions Modifications connections opening up or repairs performed by non authonzed personnel eNatural wear and tear because of the use of the product eDevices of which the seral number has been removed has become illegible alterated whiped out or changed The manufacturer cannot be held responsible for damages caused to objects or persons as the consequence of the failure to observe the detailed wamings and users instructions Possible changes no changes may be made without the manufacturers previous authonzation After receiving the damaged device the product will be revised before accepting the apply of the warranty The merchandise must be send in free port The warranty is only valid if the product is sent with the present document which has to be signed and filled out by distnbuting company and with a fiscal document confirming the date of purchase Any controversy that may occur falls under the exclusive competence of the spanish judicial authonty ee a a EMA www ema es MN 3000 User s Manual for performing treatments DECLARATION OF CONFORMITY DECLARACION DE CONFORMIDAD DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE 89 336 CEE 73 23 C EE Nombre del Fabricante Manufacturers name Nom du fabric art Direcci n dei Fabr

Download Pdf Manuals

image

Related Search

MN 8000 mn 80008 district mn8000 min 8000tl-x min 8000tl-x2 min 8000tl-x e datasheet min 8000tl-x2 datasheet min 8000tl-x inmetro min 8000tl-x2 inmetro m8000 m8000 plc m8000phd

Related Contents

FOS 100 DYNAMIC FULL RGBW User manual rel 2.1  Philips Exhaust filter CRP772  Concord LCD Keypad with 2-Way Voice Installation Sheet  Monographie de produit (télécharger PDF, 4822KB)  Melissa Cordless Jug Kettle 245-035 User's Manual  Istruzioni per l`uso  MANUAL DE INSTRUCCIONES 2013 85 SX 19/16 85 SX 17/14  Lake Shore Model 475 Gaussmeter Manual  MANUAL DE INSTRUÇÕES    