Home
Agilent N1019A-N5467B/C User Defined Application
Contents
1. Modifications Application Generator Setup Tab e Fixed renaming of external instrument nickname Build Tab e Fixed premature build error regarding image full path exceeding 259 characters Agilent N1019A N5467A User Defined Application Version 01 71 Released Date 1 September 2012 Application Generator Supported Operating Microsoft Windows XP Service Pack 2 or later Systems Microsoft Windows Vista Microsoft Windows 7 Infinitum Real Time Generated App Minimum 5 70 80000 series Infiniium Oscilloscope Baseline Version 1 41 90000 series 90000 X series 2 00 9000 series FlexDCA Generated App Minimum FlexDCA 1 80 Version File Name SetupInfUserDefApp01710002 exe Additions Application Generator SetupTab e You may now execute SetVariable steps when the GeneratedApp s user selects a test group filter on the Set Up tab Generated App e New File gt Execute Script menu item and automation command enables end users to launch arbitrary scripts How To e New How To topic in User s Guide describes how to create custom formatted tests results Modifications Application Generator File Menu e Now when you open a project that uses Full Path variables in Load Setup Mask steps and Apply Transfer Function steps you no longer get prompts to export missing files Config Tab e Fixed missing Find References to internal and config vars in various steps Generated
2. Modifications Application Generator You may no longer create Add Ins that target compliance apps supporting only Add In Interface 1 0 Tools Menu e Options gt Launch items moved to new Generated App tab Agilent N1019A N5467A User Defined Application Version 01 76 Released Date 11 October 2013 Application Generator Supported Operating Systems Microsoft Windows XP Service Pack 2 or later Microsoft Windows Vista Microsoft Windows 7 Version Infinitum Real Time Generated App Minimum 5 70 80000 Series Infiniium Oscilloscope Baseline Version 1 41 90000 Series 90000 X Series 90000 Q Series 2 00 9000 Series FlexDCA Generated App Minimum FlexDCA 1 80 File Name SetupInfUserDefApp01760000 exe Additions Application Generator Tools Menu e Option gt Miscellaneous New option to preserve the generated app s In Tool Launch documents directory default project location Set Up Tab e New external instrument option to disconnect from the instrument during In Tool Launch useful for externals such as Agilent VSA which only allow one client connection at a time Steps e DisplayMessage step now has a Browse Button option in the AskForData group so you can prompt user for a file location Modifications Application Generator Connections Tab e When you add a connection alternative value the tool no longer automatically prepends the name of
3. the connection e You may embed spaces in a connection alternative value Steps e Fixed use of Launch External App step in a While loop e Added more error checking to Text expressions Math Library e Fixed Math WorstForRange Double Double Double may return wrong value Debug Run e When you start a Step Debugger session the tool now automatically sets the Reserved_OtherFilesDir variable e In Tool Launch from PC When you exit the generated app it now prompts you to restore the scope s previous setup e Fixed Parse Multiple Values when parse characters space plus any other characters e Fixed bug After defining external instrument with wrong sockets setting and trying to connect failed to allow you to change the sockets setting until you restarted the tool Generated App FlexDCA only Removed DefaultSetup command that was executing before the start of every run Fixed uninstaller Note To manually remove a generated app delete these directories from the machine where the app is installed FlexDCA App WinXP C Documents and Settings All Users Application Data Agilent FlexDCA Apps User Defined lt appname gt C Program Files Agilent FlexDCA Apps User Defined lt appname gt FlexDCA App Win7 C ProgramData Agilent FlexDCA Apps User Defined lt appname gt C Program Files x86 Agilent FlexDCA Apps User Defined lt appname gt Infiniiium App WinXP C Documents and Settings All Users Appl
4. Supported Operating Systems Microsoft Windows XP Service Pack 2 or later Microsoft Windows Vista Generated App Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 2 00 9000 series File Name SetupInfUserDefApp01220001 exe Modifications Generator Tool File Menu e Now you can open projects when your PC has language localization enabled Configs e Now removes leading and trailing spaces from config definition entries preventing phantom config issues Generated App Launch e No longer reports malformed run options when an event contains a SetVariableStep whose source is a SCPI command 33 Agilent N5467A User Defined Application Version 01 21 Released Date 14 May 2010 Generator tool Supported Operating Systems Microsoft Windows XP Service Pack 2 or later Microsoft Windows Vista Generated App Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 2 00 9000 series File Name SetupInfUserDefApp01210001 exe Modifications Generator Tool File Menu e Build Fixed a recursive subroutine error that would sometimes be reported when there was no recursion Steps e You are now prevented from creating a Math Expression in which you pass a multi term expression as an argument to a function call e g Math Abs x y The UDA step execution engine does not ha
5. a non engineering formatted string if the value is a whole number The External Instrument Definition dialog now warns about reference changes only when you change the nickname case sensitive You can now control external instruments via a SICL socket address such as the N4903A J BERT high performance serial BERT 31 Build Results Pane Fixed build error line number when error step is preceded by one or more comments When you enable or disable a step it now moves to the center of the visible window now matches the edit step behavior In While blocks containing a ContinueWhile followed by BreakWhile the Break is now skipped Generated App Added splash screen to installer Now supports Remote Interface version 1 70 Fixed a crash that could occur when the generated app contained a long running while loop Application installer is now fully automated Scope When a scope is missing the UDA option license installed UDA apps now appear under Analyze gt Unlicensed Apps submenu When an abort step fires in a Run Event you can now see the message you specified in the step No longer throws exception when you use a config value that looks like a numeric too big to fit inside a double precision float var e g 1E9841345714544 An IntermediateValue step followed by an AbortStep will no longer terminate the application 32 Agilent N5467A User Defined Application Version 01 22 Released Date 13 July 2010 Generator tool
6. dialog e lt ctrl gt A now selects all steps e Improved cursor behavior when adding and deleting test steps Events e Any Test Group Starts Fires every time test flow enters a new group at any level including the RootGroup e App Shown Fires as soon as the generated app is launched 35 Modifications Generator Tool File Menu New Project now removes group specific events Make Project Editable now works when the project has no user files Tools Menu Moved Predefined Variables button to Tools gt Manage gt Reserved Variables You can now find references to reserved variables Some keyboard shortcuts in the Manage menu and in the Choose Step Type dialog were changed to make the two lists consistent External Instruments Fixed error message when you edit an existing definition Debug Run Dialog At the start of each Debug Run session now sets all internal variable values to value NaN Nota Number Now displays the current values of all internal and config variables directly referenced by the steps in the list Breakpoints now indicated as a B in the first column No longer executes commented out steps inside subroutines When running the generator tool on a scope no longer asks you for the SICL address now automatically uses lan localhost inst0 Added protection against recursive subroutine calls You may now copy and paste steps between step containers The lt ctrl gt x k
7. in a generated app e Manage gt Other Files You may now have a period in your custom install directory e g c temp mydir something Modifications Generator Tool Custom Math Libraries compiled against previous versions of N5467A must be rebuilt to work with this version See the Managing Math Libraries topic in the user manual Removed Basic Mode Build Generator tool no longer hangs when you build an event step that calls a recursive subroutine Now generates build error if a non CommandFile step refers to a non existent external instrument Set Up tab Displayed build number now dynamically updates each build When you rename an external instrument the change is now propagated to the steps Tests tab Now warns when you are about to delete a test group that has run events associated with it Debug Run You can now persist internal variable values across debug runs via the Tools gt Options dialog Debug Run Echo Console now displays Console App launch command args Fixed on scope debug run involving external instruments Step Editor Console App step no longer complains about missing success text when verification is turned off Miscellaneous Parsing Wherever you can specify how text is parsed you can now specify more than one character the text will be split every time any of those characters is found This includes special characters enabling parsing of multi line files Yvar syntax now returns
8. now optional see Tools gt Options Display Config tab e Deprecated config variable names containing characters other than alphanumeric or underscore Recommend existing ones be changed to meet new criteria although legacy projects with deprecated names will build and run as before Connections Tab e Connection Editor now enables you to specify whether you want this connection prompt to reset the scope or not Debug Runner e No longer initializes internal variables to NaN Not a Number this enables steps to fail if an internal variable has not been set before being used which is what happens in the generated app Resetting internal variables now puts them in an uninitialized state e Improved variable identification in the Debug Run dialog box s variable watch window Automation Tab e Default automation script uses new remote interface command SelectAllTests e When automation script encounters an Exit step it now aborts the rest of the script or file Generated App Add In For final result steps with rounding gt 10E2 now performs rounding before comparing to pass limits This behavior already existed for rounding lt 10E2 Fixed File not found error when external app scripts executed from within Subroutines or Events Fixed the User Message Step s Ask prompt Suppression Response Generated App only Existing Results screen which may display at the start of a run now shows you how many tria
9. now inserted immediately after the selection Tool now warns you upon renaming a config or internal variable that references in command files will not be updated Test and Event step lists are now editable via a separate dialog The Debug Run button in the Test Definition dialog now enables you to combine that test s steps with associated events to exercise a more complete run The Debug Run button in the Events tab now enables you to combine events to exercise a more complete run The Events combo box entries are now listed in order of runtime execution Build now catches conditions leading to image file paths that would exceed the file system max of 259 characters Find Config References now finds usages in Intermediate Value and Final Result steps Set Variable step exceptions are now handled by the standard runtime abort handler no dialog will interrupt the run now When you change a config s label all steps referring to that config by label are now updated 40 When Intermediate or Final Result step reports either a config variable or a math expression you can now include an image VAR clauses in External App step Args field now work correctly When you edit a test whose pass limit is a single ended non range value of 0 you no longer get false limit changing warning if you do not change the limit When you edit a Set Variable step the variable box now defaults to the current variable name The requirement to
10. when the app is in Debug mode e Options gt Debug Maintain option now split into two options Compatibility Tab e New Add In Interface Level 14 SetupTab e New field for specifying minimum required scope firmware version for your generated application Tests Tab e New steps Default Scope Setup Transfer External File HTML Table Operation Complete Get SCPI Error Clear SCPI Error Cache e Single SCPI Command New option to disable automatic SCPI Error checking to manually inspect errors e New text compare operators for If and While step predicates StartsWith EndsWith and Contains e Intermediate Final Result steps New option to disable engineering formatting Step Debugger e New Return button to make it clearer how to exit a subroutine or event after you Step In Configs Tab e For user editable configs you can now validate what the user enters against a min max Connections Tab e You can now use a variable to determine which connection prompt to display Events Tab e New option to not default scope when generated app launches Miscellaneous Tab e You can now specify a Getting Started document to be included in the help Modifications Application Generator Tests Tab e You can now put line breaks n in a test s Description and Reference fields e When you copy a test group the tests it contains now get copied e Now supports variables in the full path of these steps Load S
11. App e You may now suppress prompts during installation using switch noprompt e AskForData dialog instruction field is now a multi line scrollable textbox e Infinitum Real Time Only Restored error text reporting for SCPI commands and queries Agilent N1019A N5467A User Defined Application Version 01 70 Released Date 20 July 2012 Application Generator Supported Operating Microsoft Windows XP Service Pack 2 or later Systems Microsoft Windows Vista Microsoft Windows 7 Infinitum Real Time Generated App Minimum 5 70 80000 series Infiniium Oscilloscope Baseline Version 1 41 90000 series 90000 X series 2 00 9000 series FlexDCA Generated App Minimum FlexDCA 1 80 Version File Name SetupInfUserDefApp01700006 exe Highlights Application Generator e Supports application development for FlexDCA as model number N1019A e Requires Agilent 10 Libraries Suite version 16 2 or newer e N1019A only You can now install the license in a PC based FlexDCA to enable control of any DCA X e New steps Default Scope Setup Transfer External File HTML Table Operation Complete Generated App e FlexDCA only You can now install generated apps on a PC e Infiniium Real Time only Loads as read only all test results created by UDA 1 60 or older apps Additions Application Generator Tools Menu e Manage gt Reserved Variables New variable Reserved_DebugMode equals True
12. Display dialogs containing tree views starting at the top of the tree The project is now marked dirty when you add remove additional files in the Manage External Scripts dialog When you load a project that contains Console Application definitions the Supporting Files list box no longer shows duplicates 38 Agilent N5467A User Defined Application Version 01 10 Released Date 04 December 2009 Generator tool Supported Operating Systems Microsoft Windows XP Service Pack 2 or later Microsoft Windows Vista Generated App Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 2 00 9000 series File Name SetupInfUserDefApp01100000 exe Additions Generator Tool You can now define subroutines of steps that can be called by Tests Events and other subroutines e See Subroutine tab in main dialog Math expressions may now include properties and function calls for external math libraries e A core math library is included with the generator tool e You may also plug in custom libraries that you create as well e See Tools gt Manage gt Math Functions New step type Load Scope Mask which enables mask testing and loads the specified mask file e As with scope setup files in order to run this step from a PC you will need to provide a scope centric path on the Debug Run tab You may now install User Defined Function files into Infiniium s UDF directory e Se
13. Microsoft Windows Vista Microsoft Windows 7 Infinitum Real Time Generated App Minimum 5 70 80000 Series Infiniium Oscilloscope Baseline Version 1 41 90000 Series 90000 X Series 90000 Q Series 2 00 9000 Series FlexDCA Generated App Minimum FlexDCA 1 80 Version File Name SetupInfUserDefApp01800000 exe Highlights Optional integrated switch matrix control e Supports instruments from Agilent BitifEye and Giga tronics e Add path correction using Infiniium real time options PrecisionProbe or InfiniiSim or FlexDCA option InfiniiSim DCA e Instrument simulators included to support development and testing Automatically execute tests over a range of config variable settings Additions Application Generator Edit Menu e New Find menu option to search only test steps Tools Menu e New Manage gt Switch Matrix menu e New Options gt Generated App gt Use Simulators option Config Tab e Editor New reset connection option e Editor New allow multi select option Connections Tab e Editor New option to define signal paths for switch matrix control Events Tab e New Permutation event fires as multi select configs cycle through choices Generated App Tools Menu e New Switch Matrix menu when app designed to control switch matrix o Requires option N5467B C 7xx Infiniium real time or N1010A 7xx FlexDCA Setup Tab e New permutation management tabs when app designed to allow multi select configs
14. Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 90000 X series 2 00 9000 series File Name SetupInfUserDefApp01610000 exe Modifications Generated App Add In Fixed installer uninstaller issues Fixed Reserved_XxxPath variables Agilent N5467A User Defined Application Version 01 60 Released Date 1 March 2012 Application Generator Supported Operating Microsoft Windows XP Service Pack 2 or later Systems Microsoft Windows Vista Microsoft Windows 7 Generated App Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 90000 X series 2 00 9000 series File Name SetupInfUserDefApp01600000 exe Highlights Application Generator e You may set internal text variables equal to quoted text variables of any type and text library properties and functions e You can now define tests as No Result for use as subroutines in Add Ins e Simplified and improved use of external instruments e You can now execute a file containing variable name value pairs to quickly set many variables at once See Debug Runner gt Set Variables screen e New instrument address finder Generated App e Installer supports Windows 7 scopes as long as app is built with N5467A version 1 50 or newer e No longer requires a license to use its remote interface e New Acquisition Setup controls see Tools gt Infiniium Additio
15. ab e Add In installer filename now includes guidance to help you identify compatible compliance applications Automation Tab e Now available for use with add in projects Generated App Add In Installer now verifies Microsoft NET 3 5 or newer is installed on scope before proceeding Verify Condition Step now responds correctly to frequency measurement query when no waveform is present App Legacy projects will be loaded as read only can t append due to changes in the data model Mention this in your generated app s Release Notes so users will not be surprised by this when they upgrade App Fixed Set Up tab test group filters App Exceptions thrown in Create Edit User Defined Limit Set screen no longer terminate the application App Fixed bug in Create Edit User Defined Limit Set screen You can now set a nominal value for case value lt 0 App New user preference to autoscroll the HTML Report to the selected test result View Preferences Report App HTML Report e Overall Pass Fail status now displayed at top e Application name now appears in the HTML Report title instead of in the Test Configuration table e Now reports if any test was run while in Debug mode see Configure tab e Added navigation buttons in between result detail sections App When you open a project made by a different application the error message now correctly reports the version the app that sa
16. add in requires to help your users avoid run time surprises see Tools gt Scope Option Requirements Generated App e You can now use Infiniium s InfiniiSim and PrecisionProbe features e New Automation Tab enables click free test selection configuration and execution Additions Application Generator Tools Menu e New Scope Option Requirements feature enables you to o Inject an Infiniium dependency specification into your generated app When you launch the generated app missing scope options will be reported o Detect when optional Infiniium features are present You will be able to abort optional tests or select alternative steps when the scope doesn t have the option s you specify Events Tab e New Any Test Ends event Miscellaneous Tab e You can now specify maximum number of trial details amp images per test these affect the corresponding generated app View gt Preferences gt Report gt Trial Display settings 21 Generated App e Now supports the InfiniiSim feature See Tools gt Infiniium e Now supports the PrecisionProbe PrecisionCable feature See Tools gt Infiniium e New Automation Tab enables click free test selection configuration and execution In this tab you can now create a script of commands that can automatically select items found in the Set Up Select Tests Configure Connect and Run tabs It s like having a remote interface client built right into the app e Supports Remo
17. afte Agilent Technologies Agilent N1019A N5467B C User Defined Application Version 01 81 Released Date 6 December 2013 Application Generator Supported Operating Microsoft Windows XP Service Pack 2 or later Systems Microsoft Windows Vista Microsoft Windows 7 Infiniium Real Time Generated App Minimum 5 70 80000 Series Infiniium Oscilloscope Baseline Version 1 41 90000 Series 90000 X Series 90000 Q Series 2 00 9000 Series FlexDCA Generated App Minimum FlexDCA 1 80 Version File Name SetupInfUserDefApp01810000 exe Additions Application Generator Tools Menu e Manage gt Switch Matrix Added support for these Agilent switch instruments N8990C R46 R47 R64 R70 Events Tab e New New Project Started event fires when generated app creates a new project Generated App e Now automatically reports every multi select config permutation in each test s results Modifications Generated App Breaking Change Now uses a VXI 11 non sockets or USBTMC driver to control BitifEye BIT2100 switch you must upgrade your switch to firmware version 3 4 1 10 or newer Select Tests Tab e Fixed completion indicators for apps having one or more multi select configs Agilent N1019A N5467B C User Defined Application Version 01 80 Released Date 15 November 2013 Application Generator Supported Operating Microsoft Windows XP Service Pack 2 or later Systems
18. cope Setup Load Scope Mask File Apply Transfer Function e You can now edit a subroutine from inside the Call Subroutine step editor e WriteToFile Step Now interprets n as a line break e Query OPC now supported in command files e Disabled test steps are no longer displayed in Tests tab preview pane e Fixed ExternalApp step Args path substitution on Win 7 e Fixed error checking of full paths when they contain a variable and illegal path characters e Fixed build reporting of illegal file path characters Connections Tab e Fixed connection diagram variable Variable rename now updates variables in the Instructions Build Tab e Fixed Install Now for non admin users on Win7 Connect to Instrument dialog now allows faster display of I0 Libs instrument names without attempting to connect to each one Improved appearance on high resolutions screens Generated App Add In Renamed Run Tests tab button from Run to Start Now supports txt file extension for ARSL scripts Now installs to c program files x86 on Win7 scopes Fixed launch from Infiniium Analyze menu on Win7 scopes Improved appearance on high resolutions screens Agilent N5467A User Defined Application Version 01 61 Released Date 6 April 2012 Application Generator Supported Operating Systems Microsoft Windows XP Service Pack 2 or later Microsoft Windows Vista Microsoft Windows 7 Generated App
19. d App Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 2 00 9000 series File Name SetupInfUserDefApp01000000 exe Initial Release 43
20. e Tools gt manage gt Miscellaneous Files You may now set breakpoints in the Debug Run dialog You can now disable an individual Test step or Event step to temporarily exclude it from the build You can now add comments to Test step lists and Event step lists Find References results are now available in the main dialog Results pane Find tab Added support for installing miscellaneous files those not already handled by another mechanism e See Tools gt Manage gt Miscellaneous Files Added predefined variables to enable you to discover certain runtime paths e See Tools gt Predefined Variables 39 Verify Condition step now has Abort Test option which respects the generated app s Preference setting Run Test Abort Action Added F1 help support for build errors Generated App Screen shots now include waveform memory scales if a waveform is displayed Modifications Generator Tool Buttons for managing external instruments have been moved to a separate dialog accessible from e Menu Tools gt Manage gt External Instruments e Set Up tab Manage buttons You may now set user editable Config variables in Set Variable steps You may now use Config variables as the source for Final Result value Tool now warns you if you try to load a scope setup or mask from within a Command or Command File step suggests you use the specialized step for these In Tests and Event step lists copied steps are
21. e The automation tab now works when you are using a custom remote interface port Step Debugger e Variable window now shows variables found in Verify Condition Step pass limits Generated App Add In Now automatically handles internal numeric variable and internal string variable name collisions between add in and host compliance application App only At start of run no longer verifies connectivity of external instruments with empty addresses App only Fixed Previous session terminated unsuccessfully restore recovered data action App only Fixed scope setup restoration upon app shutdown App only Fixed Remote User Port usage on Win 7 scopes App only Fixed remote interface startup warning when last session left an automation script open 20 Agilent N5467A User Defined Application Version 01 50 Released Date 1 September 2011 Application Generator Supported Operating Microsoft Windows XP Service Pack 2 or later Systems Microsoft Windows Vista Generated App Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 2 00 9000 series File Name SetupInfUserDefApp01500000 exe Highlights Application Generator e You may now control which oscilloscopes your generated applications can be executed on contact your Agilent sales representative for information on custom UDA licensing e You can now specify which scope features your generated app or
22. eyboard shortcut has been removed Now when you add steps they get inserted above the selected line When you edit a step whose value source is a Config the Specify Value Source dialog now defaults to the correct config DisplayMessage Step Now you can display messages with response choices such as OK Cancel Yes No etc and access the user s response in a variable 36 Configs LoadMask Step Build now works when running on PC even if you have not entered the Mask File Path on the Debug Run tab yet SetVariable Step You can now set a user editable config to arbitrary text SleepStep You may now use a math expression to define the duration Fixed Rename action when the label is a superset of the variable name Subroutines Events Build Now you can delete steps causing recursive loops Now prevents you from adding a call to a subroutine directly or indirectly containing an Intermediate Value step When you rename a test group the associated group specific Event is now renamed instead of replaced Now you no longer get an error when launching the generated app from within the tool when the scope does not have an App Remote license Managers Internal Variables You may now change references from one internal variable to another Internal Variable Names may now also contain underscores _ ManageConsoleApps Removed Substitute option now use Change Refs You may no
23. ication Data Agilent Infiniium Apps User Defined lt appname gt C Program Files Agilent Infiniium Apps User Defined lt appname gt Infiniium App Win7 C ProgramData Agilent Infiniium Apps User Defined lt appname gt C Program Files x86 Agilent Infiniium Apps User Defined lt appname gt Agilent N1019A N5467A User Defined Application Version 01 75 Released Date 7 May 2013 Application Generator Supported Operating Microsoft Windows XP Service Pack 2 or later Systems Microsoft Windows Vista Microsoft Windows 7 Infiniium Real Time Generated App Minimum 5 70 80000 Series Infiniium Oscilloscope Baseline Version 1 41 90000 Series 90000 X Series 90000 Q Series 2 00 9000 Series FlexDCA Generated App Minimum FlexDCA 1 80 Version File Name SetupInfUserDefApp01750000 exe Additions Application Generator File Menu e Export Definitions Exports a summary of key aspects steps variables of the project Tools Menu e Manage gt Text Libraries Added FormatNumber function Events Tab e Added App Shown Demo Mode event to execute steps when generated app is started in no scope demo mode Modifications Application Generator On launch warns user if their PC s current regional settings use a character other than period for number decimal Fixed various keyboard shortcuts Fixed screen relocation bug on multi monitor computers Edit Menu e Find No
24. iium Only HTML Report now includes probe info e Now supports multi line user comments Agilent N1019A N5467A User Defined Application Version 01 73 Released Date 1 December 2012 Application Generator Supported Operating Microsoft Windows XP Service Pack 2 or later Systems Microsoft Windows Vista Microsoft Windows 7 Infiniium Real Time Generated App Minimum 5 70 80000 Series Infiniium Oscilloscope Baseline Version 1 41 90000 Series 90000 X Series 90000 Q Series 2 00 9000 Series FlexDCA Generated App Minimum FlexDCA 1 80 Version File Name SetupInfUserDefApp01730000 exe Highlights Application Generator e Breaking Change Removed Operation Complete step Now use new Query Operation Complete option inside the Single SCPI Command step editor e _Infiniium apps may now be enabled for installation on a PC Additions Application Generator Tools Menu e Manage gt Reserved Variables New Reserved_XxxAddress Xxx Infiniium or FlexDca variable holds the connected scope application s address Modifications Application Generator e Breaking Change Removed Operation Complete step Now use new Query Operation Complete option inside the Single SCPI Command step editor e Added ability to see reference counts and to see and set Debug Run value to more places e Enhanced scope family firmware minimum required version cross checking File Menu e Save No longe
25. indows Vista Generated App Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 2 00 9000 series File Name SetupInfUserDefApp01010000 exe Additions Added new entries in the Tools gt Manage menu to support connection diagrams and external application scripts Modifications External Application Dialog e Redesigned to clarify difference between executing a program and a script e Scripts are now always installed e Scripts are now installed in the generated application s installation location e You may use VAR variables in the Script Full Path filename If you abort an open project action after selecting the project a new project is now always started You can now modify a connection definition to use a different image or custom HTML file even when the new file has the same name as the old one as long as the old file is not currently used by any other connection definition External app step scripts are now always saved with the project In the Manage CommandFiles ConnectionXxx ScopeSetupFiles dialogs the Browse button in the Change References action now starts in the last directory used for that file type 42 Agilent N5467A User Defined Application Version 01 00 Released Date 1 July 2009 Generator tool Supported Operating Systems Microsoft Windows XP Service Pack 2 or later Microsoft Windows Vista Generate
26. later Systems Microsoft Windows Vista Generated App Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 2 00 9000 series File Name SetupInfUserDefApp01410000 exe Highlights Add In projects only Now supports Add In Interface version 1 11 App projects only New App Exits event New Ask For Data prompt Increased availability of Reserved variables Improved Insert Variable Improved pass limits handling of zero case New generated app remote interface command SelectAllTests Additions Application Generator Tools Menu e Options Added new Display tab entries Tests Tab e User Message Step New Ask For Data prompt to get input from users e Margin formulas are now shown in the info pane Debug Runner e Added an Apply button to the Set Variable For Debug Run screen so you can continue setting other variables Events Tab e App projects only New App Exits event executes its steps when the user exits the generated app Generated App Add In New remote interface command SelectAllTests 23 Modifications Application Generator Changed the screen displayed when you exit the tool while unsaved changes exist Tools Menu e Manage Internal Variables Restored Add behavior to close dialog by default Leave Open behavior is now optional see Tools gt Options Display Add In projects only Compatibili
27. longer automatically connects to the saved scope address e Projects saved with version 1 74 or newer will not restore Debug Run tab settings when opened on a different PC Build e Generate Installer and Install Now are no longer aborted if the tool was unable to generate the remote interface help file Generated App Installer e Now removes _mcr directories for UDFs being installed e Add In Only Fixed installation of Other files Everywhere units are specified limits results etc they are now separated from the number by a space e g 1 5 GHz Instrument Connection e You may now refer to sockets based instruments using Visa Aliases and SICL addresses with host names or IP address Steps e Fixed SYSTEM PRESET command when sent to external instruments e Now restores user specified bandwidth limit Tools gt Infiniium gt Acquisition Setup after a LoadMask step executes e Ifa single SCPI command generates more than 1 entry in the instrument s error queue all errors are now read and reported at the same time Configs e Fixed use of config variables whose names are values are numbers and whose values name 1 Tools e Real Time Only When using Infiniium 4 20 or newer checking Tools gt Acquistion Setup gt Enable no longer causes recalculation of existing on screen measurements Automation e SuppressSimpleMessages now suppresses Compliance Debug mode toggle prompts HTML Report e Real Time Infin
28. ls exist for each test result to be modified Generated App only Fixed HTML Report Logo Generated App only HTML Report now shows you the limit set that was active during the last run not the one currently active 25 Agilent N5467A User Defined Application Version 01 40 Released Date 18 February 2011 Application Generator Supported Operating Microsoft Windows XP Service Pack 2 or later Systems Microsoft Windows Vista Generated App Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 2 00 9000 series File Name SetupInfUserDefApp01400001 exe Highlights You can now e Create dynamic pass limits using internal variables e Create information only tests that have no pass limits e Set internal and config variables during a Debug Run e Launch an add in from within the generator e Get full screen scope images e Use a helper to insert var clauses Details below Additions Application Generator Tools Menu e Add Ins Options gt Miscellaneous tab New setting for choosing the default minimum Add In interface for new projects Various screens now provide an Insert Variable helper to construct var clauses 26 Tests Subroutines Events Tabs e Manage Steps screens have a new Extract button that will move the selected steps into a new subroutine e You can now set internal and config variable values from the Debug R
29. make Intermediate and Final Result step labels unique is now a case sensitive comparison The Connection Changing event now only fires if the user actually changes the connection clicks Next not Ignore When developing on an oscilloscope you can now execute a Load Setup step within a Debug Run Fixed various text boxes that would jump the cursor to the end when you typed in them While a generated app is running the main dialog status bar now indicates this and you can no longer perform a build Added validation to pass limits Nominal field Console App Step Use Timeout now unchecked when disabled Now you can only add Test Groups when either the Tests or Config tab is active Generated App Now uses remote interface version 1 40 Improved stability on runs gt 48 hours in duration When you save a project now warns if the path length you choose would cause one or more of the project s files to exceed operating system max path length File gt Export Results gt CSV output is now sorted the same way as results are displayed in the Results tab Configure tab combo box caption now says Select a value or Select or type in a value to indicate whether or not it accepts user defined text 41 Agilent N5467A User Defined Application Version 01 01 Released Date 28 August 2009 Generator tool Supported Operating Systems Microsoft Windows XP Service Pack 2 or later Microsoft W
30. ndle these types of arguments yet e You are now prevented from including library functions or properties in IF and WHILE step predicates e g if x lt Math Abs y The UDA step execution engine does not handle these types of predicates yet Generated App Installer e Now opens up port exceptions in the oscilloscope s firewall to enable control of the generated app via its remote interface in case no previous app had ever opened these ports 34 Agilent N5467A User Defined Application Version 01 20 Released Date 15 March 2010 Generator tool Supported Operating Systems Microsoft Windows XP Service Pack 2 or later Microsoft Windows Vista Generated App Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 2 00 9000 series File Name SetupInfUserDefApp01200000 exe Additions Generator Tool File Menu e You may now export and import individual tests and subroutines Tools Menu e Debug Run You may now reset each config s Debug Run value to its default value Steps e If Else and Endlf Steps now enable you to create conditional blocks of steps e While Break Continue and EndWhile Steps now enable you to repeat blocks of steps e Abort Step now enables you to stop the test or run in progress e Return Step now enables you to exit a subroutine or event before its last step Modify Steps
31. ns Application Generator Tools Menu e Manage gt Internal Variables o You can now define internal variables that hold text and use them anywhere you can use internal numeric variables except for math expressions e Manage gt Text Libraries o You can now import libraries containing custom text properties and functions e Options gt Miscellaneous o New option to preserve generated app s user preferences during In Tool Launch Tests Tab e You can now define tests as No Result for use as subroutines in Add Ins See Final Result Step Limit Type e Steps may now use text expressions consisting of quoted text variables of any type and text library properties and functions Configs Tab e App only You can specify a config as Debug Only displays only when generated app is in Debug Mode Debug Run Tab e Set Address feature now includes an instrument address finder Step Debugger e You can now set a reserved variable s value e You can now execute a file containing variable name value pairs to quickly set many variables at once See Set Variables screen Generated App Add In The address a user enters for an external instrument is now stored in reserved variable named Reserved_ lt name gt Address App only e New Acquisition Setup controls see Tools gt Infiniium e Set Up tab now helps you find addresses of required external instruments e New calibration wizard on PrecisionP
32. on setting now called Maintain is now saved restored between application generator sessions Tests Connections Subroutines Events Tabs e Now filters entries in a VariableName combo box as you type Tests Subroutines Events Tabs e You can now use internal variables in a Verify Condition Step s limits e Debug Run o Added protection to prevent errors that occur during Debug Runs from terminating the application generator o Add Ins Now lets you include the User Defined Group Ended event Tests Configs Connection Tabs e You can now rename tests configs and connections using names that differ only by capitalization Tests Tab e You can now use internal variables in a test s Final Result pass limits e You can now define tests that have no pass limits e You can now create test groups for your add in s tests e Now when you edit a test that has steps the Step Editor automatically opens Configs Tab e You can no longer set the value to use for a Debug Run from the Config editor screen now use Debug Runner screen Connections Tab e You can now associate connection instructions with whole test groups instead of with individual tests enabling a diagram to display before the group s event steps execute Events Tab e You can now add steps to an add in s sub group events e Fixed use of WriteFileStep in Events no longer get malformed run option error during generated app startup 28 Build T
33. r tries to save previously entered custom html file when connection is changed back to Simple e You may now import fragments into a project that has no tests Tools Menu e Options Fixed NoScope Preview Mode e FlexDCA Only Added support for Scope Option 86100DU 401 Advanced Eye Analysis Tests Tab e Fixed use of channel variables in ApplyTransferFunction step Build Tab e Infiniium apps may now be enabled for installation on a PC DebugRunTab e Connect To Instrument prompt now offers sockets based connections when appropriate e Infiniium Real Time Only Simplified DebugRun setup requirements when the connected scope supports file transfer Infiniium 4 10 or later Generated App e FlexDCA only Fixed screen shots when image label contains an apostrophe e FlexDCA only Fixed screen shots when N1019A and FlexDCA are running on same machine but N1019A is connected to another address Agilent N1019A N5467A User Defined Application Version 01 72 Released Date 1 October 2012 Application Generator Supported Operating Systems Microsoft Windows XP Service Pack 2 or later Microsoft Windows Vista Microsoft Windows 7 Version Infinitum Real Time Generated App Minimum 5 70 80000 series Infiniium Oscilloscope Baseline Version 1 41 90000 series 90000 X series 2 00 9000 series FlexDCA Generated App Minimum FlexDCA 1 80 File Name SetupInfUserDefApp01720000 exe
34. robe PrecisionCable input screen Modifications Application Generator Installation Updated Agilent Licensing component to latest version Add In only No longer hides features that are not available at too low an add in interface level instead issues error if they are used File Menu e The Generator tool now prevents you from overlapping your working files and saved project locations e Fixed conversion to add in of apps containing test groups e Import Fragment now updates imported steps affected by a config rename and updates imported pass limits affected by an internal variable rename Set Up Tab e Simplified construction external instrument definition by offering standard error query response rules Tests Tab e You can now use variables in an External Application step to specify the entire Program Full path or Script Full path e You can now set a timeout value for LoadSetup LoadMask and ApplyTransferFunction steps e More types of combinations and comparisons are now allowed in conditional predicates e Fixed multi value parsing when the parse character is a double quote Configs Tab e Changing a config s variable name now correctly updates SetVariable steps e Reference search now finds config variables on the right hand side of a IfStep or WhileStep predicate Automation Tab e You no longer need an N5452A remote interface license to use the N5467A s automation feature
35. te Interface Version 2 00 e When installed on the scope the generated app now enables you to access its remote interface help file through menu button help gt Modifications Application Generator Installer now requires PC to have Agilent IO Libraries 15 1 or newer File Menu e During Open Project if you export additional external app scripts the path to the files will now be adjusted in the Manage External Application Scripts dialog box Tests Tab e Editing an If or While step predicate no longer produces Please specify a variable to be compared error e When you create an internal variable from within the Predicate Term Definition dialog the variable is now selected Debug Runner e Fixed SYSTEM PRESET execution from within DebugRun e Setting a variable in the Debug Run dialog no longer produces Please select an internal variable to set error Generated App Add In e Generated App only Remote interface no longer requires the Infiniium scope option App Remote ID CRI You can now remotely control your generated app on any scope e Generated App only Improved behavior of Run progress meter e The installer now requires the logged in user to have administrator privileges 22 Agilent N5467A User Defined Application Version 01 41 Released Date 30 April 2011 Application Generator Supported Operating Microsoft Windows XP Service Pack 2 or
36. ty Tab e Now supports Add In Interface version 1 11 Set Up Tab Fixed external instrument description field Tests Tab Fixed Verify Condition Step rounding for PrecisionLevel gt 0 case e Improved variable validation in dialog boxes that allow you to enter var substitutions Pass Limits o For variable or zero single ended limits now provides a default Nominal value o For variable single ended limits now enables user to enter a Nominal value e You may now do the following with a Reserved variable o Set Config variable equal to a Reserved variable if the config is editable o Write the Reserved variable s value to a file o Report the Reserved variable s value in the results o Use the Reserved variable on the right hand side of a conditional predicate text comparisons only e g if MyConfig Reserved_xxx e Inthe Specify Value Source screen when the Source is Text you may now insert variables e You can now report arbitrary text in an Intermediate Value step e When using Insert Variable to choose a variable o You no longer have to match the case of the variable you are looking for e g myvar matches MyVar o You can add a trailing space to match the end of the name e g myvar matches MyVar but not MyVar2 o You can access the Manage screen to add new internal variables 24 e Restored Edit behavior to open Test Definition screen by default Auto Manage behavior is
37. um is running on and the machine the generated app is running on For an add in this feature requires Add In Interface 1 16 Miscellaneous Tab e You can now include sample results projects created by your generated app in your installer Modifications Application Generator On launch warns user if their PC s current regional settings use a character other than period for number decimal Fixed various keyboard shortcuts File Menu e Export Import Fixed behavior when group associated connection prompts exist Edit Menu e Find You can now search for text you typed in the project Tools Menu e Scope Option Requirements Fixed editing of existing Required Alternatives and Optional Alternatives e Manage Internal Variables Fixed variable renaming impact on Connection Alternatives Set Up Tab e You can no longer assign nickname scope to an external instrument Steps e Single SCPI Command Fixed error message when editing existing step after renaming an external instrument e f While steps Fixed text comparisons when operands contain commas Step Debugger e If you execute a single SCPI command that generates more than 1 entry in the instrument s error queue all errors are now read and reported at the same time Connection Prompts e Connection Alternative values are now checked to ensure they contain only alphanumerics and underscores Debug Run e When opening a project the tool no
38. unner screen Tests Subroutine Tabs e You can now select a full screen image for an Intermediate Value step Add Ins New Compatibility Tab e Enables you to trade off new features in your add in for increased legacy application compatibility Tests Tab e You can now select a full screen image for a Final Result step Miscellaneous Tab e You can now specify a txt Release Notes file Modifications Application Generator Increased enforcement of internal variable case sensitivity File Menu e New Project now resets all internal and config variable values e Open Project now restores the Debug Run values for internal and config variables to what they were when the project was saved Ensure Tools gt Options Debug Maintain is checked before you start the Debug Run to avoid resetting these e Open Project now restores the build number 3rd segment of version field e You can no longer use an older version of the N5467A application generator to import a fragment created by a newer version You may find that some fragments created by 1 40 will fail to import into 1 30 projects Please upgrade to N5467A version 1 40 Build Menu e You can now Launch an add in to test it without having to install it in a real compliance application 27 Tools Menu e Manage gt Internal Variables You can now add multiple internal variables more easily e Options Debug Persist user preference opti
39. ved the project App Fixed loading of projects made by different applications when the application s name is listed as a compatible app Add In Fixed installation of custom other files when the destination directory does not already exist Add In Add In tests now identify themselves as User Defined in the host application s HTML Report Add In Interface 1 10 or later Add In Add In now reports its beta release status in the host application s Help gt About screen and HTML Report Add In Interface 1 10 or later 29 Agilent N5467A User Defined Application Version 01 30 Released Date 2 November 2010 Microsoft Windows Vista Generator tool Supported Operating Systems Microsoft Windows XP Service Pack 2 or later Generated App Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 2 00 9000 series File Name SetupInfUserDefApp01300004 exe Additions Generator Tool You can now create Add Ins that can be installed into existing compliance applications New Automation tab enables you to automate generated app behavior Tools Menu e Manage o New Reserved Variable Reserved_ProjectAppPath e Options o New Build tab o New Debug tab Steps e New Apply Transfer Function Step e New Write File Step Events e New Any Trial Ends Event Miscellaneous e You can now include a test procedure PDF file
40. w export search results to a file Math Libraries IDs may now also contain numbers and underscores _ You may no longer load the same library twice Other Files you can now edit an entry to point to the same named file in a different directory Generated App Remote interface upgraded to version 1 60 37 Agilent N5467A User Defined Application Version 01 11 Released Date 27 January 2010 Generator tool Supported Operating Systems Microsoft Windows XP Service Pack 2 or later Microsoft Windows Vista Generated App Minimum Infiniium Oscilloscope 5 70 80000 series Baseline Version 1 41 90000 series 2 00 9000 series File Name SetupInfUserDefApp01110000 exe Additions Generator Tool Non Agilent Technologies external instruments SCPI compliant are now supported Modifications Generator Tool Fixed intermittent N5467A installer upgrade failures An event may no longer include Intermediate Value steps or subroutines that call them causes error at generated app runtime When you abort an Open Project action a new project is now started Now finds references to config variables used inside connection definitions Now respects user provided timeouts for queries when value source is scope or external instrument Debug Run now works with steps involving configs that have parentheses in their labels Now handles bad external instrument addresses more gracefully
41. w finds text in math expressions and in Single SCPI Command steps that target external instruments Connections Tab e Fixed Connection Alternatives when connection name contains underscore _ characters Debug Tab e Fixed I0 with 81134A pulse generators Generated App Fixed memory management when opening large projects with lots of images Fixed intermittent control related exceptions thrown by Run dialog during very long runs Agilent N1019A N5467A User Defined Application Version 01 74 Released Date 7 March 2013 Application Generator Supported Operating Microsoft Windows XP Service Pack 2 or later Systems Microsoft Windows Vista Microsoft Windows 7 Infiniium Real Time Generated App Minimum 5 70 80000 Series Infiniium Oscilloscope Baseline Version 1 41 90000 Series 90000 X Series 90000 Q Series 2 00 9000 Series FlexDCA Generated App Minimum FlexDCA 1 80 Version File Name SetupInfUserDefApp01740000 exe Highlights Application Generator e You can now search for text you typed in the project see Edit gt Find e You can now transfer files between the scope application and the generated app when they are on different machines e You can now include sample results projects created by your generated app in your installer Additions Application Generator Steps e Transfer File step You can now transfer files between the machine the scope application FlexDCA or Infinii