Home
AutoHoot Quick Start Guide
Contents
1. in OFF position 3 On power up the Hoot Button must be held pressed for 15 seconds 15 SEC 4 When both red amp green LEDs turn on release the Hoot Button RELEASE 5 Press the Hoot Button the number of times equal to the 10 s of the sequence number required e g for Sequence No 23 press Hoot Button 2 times Red LED will flash off when button pressed 6 Rotate Auto Switch to ON position 7 Press the Hoot Button the number of times equal to the 1 s of the sequence number required e g 000 for Sequence No 23 press Hoot Button 3 times Green LED will flash off when button pressed 8 Rotate Auto Switch to OFF position 9 The red and green LEDs will turn off 10 The red and green LEDs will flash to indicate the selected sequence as at on power on see section above This sequence is now active Note If the sequence selected does not exist the active sequence will remain unchanged Note If the selection process is not completed the unit will time out 15 seconds after the last action The active sequence will remain unchanged AutoHoot is pre programmed with the following 37 sequences The default active sequence is no 1 No Name Description 1 Rule 26 1 5s rep no delay ISAF Rule 26 5 4 1 start 1 5 sec hoots with long hoot at 1 min to go multiple starts at 5 min intervals no delay before first signal Rule 26 1 5s no delay ISAF Rule 26 5 4 1 start 1 5 sec hoots with long hoot at 1 min to go one star
2. 0 Rule 26 2 5s 10min rep 10s ISAF Rule 26 5 4 1 start 2 5 sec hoots with long hoot at 1 min to go multiple delay starts at 10 min intervals 10 sec delay before first signal 11 3 2 1 long O rep no delay 3 2 1 start with long hoot at 1 min to go multiple starts at 3 min intervals no delay before first signal 12 3 2 1 long 0 no delay 3 2 1 start with long hoot at 1 min to go one start only no delay before first signal 13 3 2 1 long 0 rep 10s delay 3 2 1 start with long hoot at 1 min to go multiple starts at 3 min intervals 10 sec delay before first signal 14 3 2 1 long 0 10s delay 3 2 1 start with long hoot at 1 min to go one start only 10 sec delay before first signal 15 5 min hoots 1 signal every 5 min 16 4 min hoots 1 signal every 4 min 17 3 min hoots 1 signal every 3 min 18 2 min hoots 1 signal every 2 min 19 1 min hoots 1 signal every 1 min 20 5 min count down 5 min count down to start 5 long hoots at 5 min 4 at 4 min 3 at 3 min 2 at 2 min 1 long amp 3 short at 1 min 30 sec 1 long at 1 min 3 short at 30 sec 2 short at 20 1 short at 10 amp 5 4 3 2 amp 1 sec amp 1 long at start one start only 21 5 min count down rep As per No 20 but with multiple starts at 5 min intervals 2 2 3 min count down Appx US Sailing RRS Appendix S Sound Signal Starting System includes 3 long hoots at S 3 min 2 at 2 min 1 long amp 3 short at 1 min 30 sec 1 long at 1 min 3 short at 30 sec
3. 2 short at 20 1 short at 10 amp 5 4 3 2 1 sec amp 1 long at start one start only 23 3 mincount down rep As per No 22 but with multiple starts at 3 min intervals 24 1mincount down 1 min count down to start 1 long hoot at 1 min 3 short at 30 sec 2 short at 20 1 short at 10 amp 5 4 3 2 amp 1 sec amp 1 long at start one start only 25 1mincount down rep As per No 24 but with multiple starts at 1 min intervals 26 3 min team race Team Racing Start 3 long hoots at 3 min 2 at 2 min 1 at 1 min 3 short at 30 sec 2 short at 20 1 short at 10 amp 5 4 3 2 1 sec amp 1 long at start one start only 27 3 min team race rep As per No 26 but with multiple starts at 3 min intervals 28 3 min team race rep 4min As per No 26 but with multiple starts at 4 min intervals 29 3 min team race rep 5min As per No 26 but with multiple starts at 5 min intervals 30 3 min team race rep 6min As per No 26 but with multiple starts at 6 min intervals 31 match race 10 min ISAF Appendix C 3 1 Match Racing Starting Signals with Attention signal at 10 min before first start start signal is the warning for next flight i e starts at 5 min intervals 32 match race 6 min As per 31 but Attention signal at 6 min before first start 33 Circuits 5x450n 20rest Circuit training each station has 5 exercises x 45 sec with 20 sec rest between stations half way signal amp 10 sec countdown to end of each exercise 34 Circuits 6x300n 15
4. AutoHoot AutoHoot iw Quick Start Guide D Thank you for choosing Richard Paul Russell Ltd s AutoHoot AutoHoot is an electronic control unit It has been designed for simple operation when a particular sound signal sequence is required to be emitted with reliable timing For full user instructions and technical specification please download the AutoHoot User Manual from our website www autohoot com CONTROLS OVERVIEW Auto Switch Turn switch to start sequence Hoot Button Press at any time to HOOT does not interrupt active Auto AutoHoot vd DD ON www r p r co uk Cable gland for power and horn a sequence wiring CONNECTION DIAGRAM AutoHoot AutoHoot Electronics 2013 Richard Paul Russell Limited New Harbour Building Bath Road Lymington S041 3SE United Kingdom Tel 44 0 1590 679755 Fax 44 0 1590 688577 e mail sales r p r co uk web www r p r co uk 1 008SL030 1 19 03 2013 AutoHoot AutoHoot l Quick Start Guide Fv QUICK START EASY STEPS TO USING AUTOHOOT Connect horn sounder to AutoHoot Connect power to AutoHoot Fasten enclosure closed and tighten cable gland Select sequence Turn Auto Switch to ON when ready to start sequence Press Hoot Button at any time if additional signal required Turn Auto Switch to OFF when sequence completed INSTALLATION USB Configuration C
5. able connection pins under PCB USB Configuration Cable Supplied separately not required if using standard Ae 12V DC power connection Terminal 2 Terminal 4 Horn sounder connection Terminal 1 Terminal 3 Horn Sounder A 12V horn or sounder needs to be connected to produce a high decibel output Power Supply 12V DC power is supplied via terminals 2 ve and 4 ve on the green connector blocks The power supply needs to be capable of supplying sufficient current to the particular horn sounder that is connected For instructions on the following features please refer to the full AutoHoot User Manual e Connection to PC via USB Configuration Cable e Output to PC of list amp details of programmed sequences e Programming of custom sequences via PC BASIC OPERATION Indication of Active Sequence On power up the LEDs will flash to indicate the active sequence The red LED will flash the 10 s followed by the green LED for the 1 s e g red LED flashes 3 times green LED flashes 5 times Sequence No 35 LEE a E E E E 2013 Richard Paul Russell Limited New Harbour Building Bath Road Lymington S041 3SE United Kingdom Tel 44 0 1590 679755 Fax 44 0 1590 688577 e mail sales r p r co uk web www r p r co uk 2 008SL030 1 19 03 2013 AutoHoot AutoHoot l Quick Start Guide Ar Selection of Active Sequence without PC connection 1 Power down AutoHoot 2 Ensure Auto Switch
6. rest Circuit training each station has 6 exercises x 30 sec with 15 sec rest between stations half way signal amp 10 sec countdown to end of each exercise 35 Circuits Circuit training circuit of 10 exercises 60 sec on with 30 sec rest between each 10x600on300ff 120rest exercise and 2 min rest between circuits half way signal amp 10 sec countdown to end of each exercise 36 Fog horn powered ColRegs Signals in Restricted Visibility Power Driven Vessels Underway 1 underway prolonged blast every 1 min 37 Fog horn sailing ColRegs Signals in Restricted Visibility Sailing Vessels Underway 1 prolonged blast followed by two short blasts every 1 min 2013 Richard Paul Russell Limited New Harbour Building Bath Road Lymington S041 3SE United Kingdom Tel 44 0 1590 679755 Fax 44 0 1590 688577 e mail sales r p r co uk web www r p r co uk 4 008SL030 1 19 03 2013
7. t only no delay before first signal Rule 26 1 5s rep 10s delay ISAF Rule 26 5 4 1 start 1 5 sec hoots with long hoot at 1 min to go multiple starts at 5 min intervals 10 sec delay before first signal 4 Rule 26 1 5s 10s delay ISAF Rule 26 5 4 1 start 1 5 sec hoots with long hoot at 1 min to go one start only 10 sec delay before first signal Rule 26 2 5s rep no delay ISAF Rule 26 5 4 1 start 2 5 sec hoots with long hoot at 1 min to go multiple starts at 5 min intervals no delay before first signal Rule 26 2 5s no delay ISAF Rule 26 5 4 1 start 2 5 sec hoots with long hoot at 1 min to go one start only no delay before first signal Rule 26 2 5s rep 10s delay ISAF Rule 26 5 4 1 start 2 5 sec hoots with long hoot at 1 min to go multiple starts at 5 min intervals 10 sec delay before first signal Rule 26 2 5s 10s delay ISAF Rule 26 5 4 1 start 2 5 sec hoots with long hoot at 1 min to go one start only 10 sec delay before first signal Rule 26 2 5s 10min repno ISAF Rule 26 5 4 1 start 2 5 sec hoots with long hoot at 1 min to go multiple delay starts at 10 min intervals no delay before first signal 2013 Richard Paul Russell Limited New Harbour Building Bath Road Lymington S041 3SE United Kingdom Tel 44 0 1590 679755 Fax 44 0 1590 688577 e mail sales r p r co uk web www r p r co uk 3 008SL030 1 19 03 2013 AutoHoot AutoHoot i Quick Start Guide a No Name Description 1
Download Pdf Manuals
Related Search
Related Contents
Owner`s Manual / Manual del Propietario October MANUAL DE INSTRUÇÕES FREQÜENCÍMETRO Electrolux EOG 10000 User's Manual Manuel d`utilisation MVME172P2 VME Embedded Controller with 2 IP Slots data sheet carryall 272 vehicles Sony KP-6lHS20 Projection Television User Manual Copyright © All rights reserved.
Failed to retrieve file