Home
MEDPC-5800 - Onyx Healthcare
Contents
1. 1 x Display Port Sound 1 x Line out 1 0 1 x Mic in One PCI Express x16 expansion optional USB2 0 5 USB3 0 2 COM 1 Display Port 1 Mic in and Line out Expansion MED PC MEDPC 5800 Mechanical Specifications Construction Metal chassis with fanless svstem design Dimension 303 2mm W x 242mm H x77 8mm D Carton Dimension 406mm x 400mm x 197mm Net Weight 4 8 Kg Gross Weight 5 5 Kg PE foam Packing Filler Power Supplv Specifications AC DC Adapter EDACPOWER EM11201B Input Voltage 100 240V AC 2 1A 50 60 Hz Output Voltage 18 24V 130W max MTBF 100 000 hrs operation at 25 C Environmental Specifications Operating Temperature 0 C to 30 C 32 F 86 F Operating Humidity 30 75 Storage Temperature 20 C to 60 C 4 F 140 F Storage Humidity 10 90 40 C Non Condensing Pressure 700 1013hPa Operating 700 1013hPa Transport Storage EMI Safety CE gt FCC Class B Passed 18 cULus Mark UL VTC Report RMF ISO 14971 CAN CSA C22 2 No 60601 1 08 ANSI AAMI ES60601 1 2005 IEC 60601 1 1 2005 EN 60601 1 2006 ISO 14971 2007 MED PC MEDPC 5800 1 4 Dimension mount kit is optional e U VavaVavavaTAVAT UNNA UI 4 RS 232 Ports are optional Isolated USB2 0 Isolated COM Isolated LAN Isolated LAN MED PC MEDPC 580
2. 31 0 499 462020 Fax 31 0 499 462010 Email eusales onyx healthcare com Onyx Healthcare Technology GmbH An der Trift65d 63303 Dreieich Germany TEL 49 0 61033 7479 00 Fax 49 0 61033 7479 49 Email eusales onyx healthcare com MED PC MEDPC 5800 Onvx Healthcare Shanghai INC 20F unit D GEM Building No 487 Tianlin Road Shanghai China Tel 86 021 6495 6588 Fax 86 021 6495 6889 Email cnsales onyx healthcare com Onyx Healthcare Singapore PTE LTD 57 Genting Lane 07 00 Singapore 349564 Tel 65 67498749 Fax 65 67461595 Email sgsales onyx healthcare com MED PC MEDPC 5800 Safety amp Warranty 1 Read these safety instructions carefully 2 Keep this user s manual for later reference 3 Disconnect this equipment from any AC outlet before cleaning Do not use liquid or spray detergents for cleaning Use a damp cloth 4 For pluggable equipment the power outlet must be installed near the equipment and must be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall could cause damage 7 The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power source is correct before connecting the equipment to the power outlet 9 WARNING To avoid risk of electric shock this equipment must only be
3. are installing a different operating system please contact your vendor for installation details Your MEDPC 5800 will begin loading Windows OS once you push the power button to turn power on After less than one minute Windows desktop screen will appear You can select the programs from the start menu in the left down corner of the desktop screen 2 4 Turn off Turning off MEDPC 5800 properly is important for system reliability 1 On the start menu click shut down and select OK 2 And then the system will shut down automatically MED PC MEDPC 5800 2 5 Rear Panel Connectors 1 DCIN DC in power jack This port is for 12V 24V DC power 2 COM COM This 9 pin COM port RS 232 is for serial devices 3 Display Port Display port This 20 pin port is for external connectors on desktops notebooks graphics cards monitors 4 USB USB 2 0 port These 4 pin Universal Serial Bus USB ports are available for connecting USB 2 0 devices 5 USB 3 0 USB 3 0 port These 9 pin Universal Serial Bus USB ports are available for connecting USB 3 0 devices 6 LANI LANZI AN RJ 45 port These port allows Gigabit connection to a Local Area Network LAN through a network hub 7 MIC mic In port light blue This port connects a tape CD DVD player or other audio sources 8 Sut Line Out port lime This port connects a headphone or a speaker In 4 channel 6 channel and 8 channel configurat
4. connected to a supply mains with protective earth 10 Position the power cord so that people cannot step on it Do not place anything over the power cord 11 All cautions and warnings on the equipment should be noted 12 If the equipment is not used for a long time disconnect it from MED PC MEDPC 5800 the power source to avoid damage by transient over voltage 13 Never pour any liquid into an opening This could cause fire or electrical shock 14 Never open the equipment For safety reasons only qualified service personnel should open the equipment 15 Warning Do not modify this equipment without authorization of the manufacturer 16 If any of the following situations arises get the equipment checked by service personnel a The power cord or plug is damaged b Liquid has penetrated into the equipment c The equipment has been exposed to moisture d The equipment does not work well or you cannot get it to work according to the users manual e The equipment has been dropped and damaged f The equipment has obvious signs of breakage 17 DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 C 4 F OR ABOVE 60 C 140 F IT MAY DAMAGE THE EQUIPMENT 18 External equipment intended for connection to signal input output or other connectors shall comply with relevant UL IEC standard e g UL 60950 1 for IT equipment and ANSI AAMI ES 60601 1 2005 AND MED
5. 0 Chapter Hardware Introduction ox MED PC MEDPC 5800 2 1 Safetv Precautions Warning Caution Always completely disconnect the power cord from your board whenever you are working on it Do not make connections while the power is on because a sudden rush of power can damage sensitive electronic components Always ground yourself to remove any static charge before touching the board Modern electronic devices are very sensitive to static electric charges Use a grounding wrist strap at all times Place all electronic components on a static dissipative surface or in a static shielded bag when they are not in the chassis 2 2 A Quick Tour of the MEDPC 5800 Before you start to set up the MEDPC 5800 take a moment to become familiar with the locations and purposes of the controls drives connections and ports which are illustrated in the figures below When you place the MEDPC 5800 upright on the desktop its front side appears as shown in Picture 1 1 mm m mm mr UU IUMUUUUUrvu UVuuv UI Picture 1 1 Front View of the MEDPC 5800 MED PC MEDPC 5800 When vou turn the MEDPC 5800 around and look at its rear side as shown in Picture 1 2 m 6 e ene e 384 98 Picture 1 2 Rear view of the MEDPC 5800 4 COM Ports are optional 2 3 Turn On and Boot up into Windows OS This section is for Windows operating system only If you
6. D ROM drive And install the drivers from Step 1 to Step 9 in order Step 1 Chipset Driver Step 2 Graphics Driver Step 3 LAN Driver Step 4 Audio Driver Step 5 USB 3 0 Driver Step 6 RAID amp AHCI Driver Step 7 ME Driver Step 8 TPM Driver Step 9 Serial Port Driver MED PC MEDPC 5800 Appendix Miscellanea ox MED PC MEDPC 5800 A 1 General Cleaning Tips Vou mav need the following precautions before vou begin to clean the computer When vou clean anv single part or component for the computer please read and understand the details below fullv 1 Never spray or squirt the liquids directly onto any computer component If you need to clean the device please rub it with a piece of dry cloth 2 Be cautious of the tiny removable components when you use a vacuum cleaner to absorb the dirt on the floor 3 Turn the system off before you start to clean up the component or computer 4 Never drop the components inside the computer or get circuit board damp or wet 5 Be cautious of all kinds of cleaning solvents or chemicals when you use it for the sake of cleaning Some individuals may be allergic to the ingredients 6 Try not to put any food drink or cigarette around the computer A 2 Cleaning tools Although many companies have created products to help improve the process of cleaning your computer and peripherals users can also use household items to clean their computers an
7. MED PC MEDPC 5800 MEDPC 5800 Intel CoreTM i7 i3 Celeron Dual Core Processor Intel QM77 Chipset Multiple display output support Fanless easy clean design MEDPC 5800 Manual 1st Ed August 2014 MED PC MEDPC 5800 Copvright Notice This document is copyrighted 2014 All rights are reserved The original manufacturer reserves the right to make improvements to the products described in this manual at anv time without notice No part of this manual mav be reproduced copied translated or transmitted in anv form or bv anv means without the prior written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibilitv for its use nor for anv infringements upon the rights of third parties which mav result from its use The material in this document is for product information onlv and is subject to change without notice While reasonable efforts have been made in the preparation of this document to assure its accuracv ONVX Healthcare Inc assumes no liabilities resulting from errors or omissions in this document or from the use of the information contained herein ONVX Healthcare Inc reserves the right to make changes in the product design without notice to its users MED PC MEDPC 5800 Acknowledgments All other product names or trademarks are properties of their Intel i7 i3 Celeron is r
8. PC MEDPC 5800 CAN CSA C22 2 No 60601 1 08 Any person who connects external equipment to signal input signal output or other connectors has formed a system and is therefore responsible for the system to comply with the standard IEC 60601 1 safety requirements for medical electrical systems 19 Warning The device intends to be used in the highly sensitive medical environments and these environments are prevented from access by general hospital staff and the device should be installed in a suitable and safe location to avoid unauthorized contact The top cover of device is allowed to be opened by authorized personnel for professional service purpose only Classification 1 Degree of production against electric shock not classified 2 Mode of operation Continuous 3 Type of protection against electric shock Class l equipment 4 No Applied Part No AP APG MED PC MEDPC 5800 FCC Warning This device complies with Part 18 FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation UL Module Description oie C US MEDPC 5800 modules are developed to suitable for the Classification Mark requirement Safety Symbol Description The following safety symbols are the further explanations for your reference Me
9. d peripherals MED PC MEDPC 5800 Below is a listing of items vou mav need or want to use while cleaning vour computer or computer peripherals Keep in mind that some components in your computer may only be able to be cleaned using a product designed for cleaning that component if this is the case it will be mentioned in the cleaning tips e Cloth A piece of cloth is the best tool to use when rubbing up a component Although paper towels or tissues can be used on most hardware as well we still recommend you to rub it with a piece of cloth e Vacuum cleaner Absorb the dust dirt hair cigarette particles and other particles out of a computer can be one of the best methods of cleaning a computer Over time these items can restrict the airflow in a computer and cause circuitry to corrode e Cotton swabs Cotton swaps moistened with rubbing alcohol or water are excellent tools for wiping hard to reach areas in your keyboard mouse and other locations e Foam swabs Whenever possible it is better to use lint free swabs such as foam swabs Note We strongly recommended that you should shut down the system before you start to clean any single components MED PC MEDPC 5800 Please follow the steps below Close all application programs Close operating software Turn off power switch Remove all device aor SUN gt Pull out power cable MED PC MEDPC 5800 A 3 Scrap Computer Recvcling If the compu
10. dical equipment with respect to electric pk shock fire and mechanical hazards only in c US accordance with ANSI AAMI ES 60601 1 2005 AND CAN CSA C22 2 No 60601 1 08 MED PC MEDPC 5800 Ground wire Protective Ground wire Attention Follow operating instructions MED PC MEDPC 5800 Contents Chapter 1 General Information 1 1 Introduction ussuunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnn 14 1 2 Feature iii 15 1 3 Specificationi uan 15 1 4 DIMENSION iii 17 Chapter 2 Hardware Installation 2 1 Safety Precautions uusuununnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 19 2 2 A Quick Tour of the MEDPC 5800 19 2 3 Turn On and Boot up into Windows 20 2 4 LUNI Off iis sile iaia 20 2 5 Rear Panel Connectors 1 gt 21 2 6 Mount Kit assembDlY cri 22 Chapter 3 Driver Installation 3 1 Installationi si ei i sess wees a te 25 Appendix A Miscellanea A 1 General Cleaning TIpS ss ss ssneennnnnnnnnzzzzzenennnnnnnnzzz 28 A 2 Cleaning Tools iii 28 A 3 Scrap Computer Recycling uiiiee 30 MED PC MEDPC 5800 Chapter General Information eo MED PC MEDPC 5800 1 1 Introduction The MEDPC 5800 is based on Intel i7 Dual Cor
11. e processor which delivers a performance improvement of more than 100 percent compared to systems running traditional single core processors With dual cores or computing engines ONYX can simultaneously execute more computing tasks It accommodates one 2 5 SATA SSD and two DDRIII SODIMM up to 16GB The fanless solution integrated multimedia functions and extensive expansion options USB2 0 5 USB3 0 2 COM 1 Display Port 1 Mic in and Line out make them the perfect platform upon which to build comprehensive lifestyle computing applications The MEDPC 5800 includes all the features of a powerful computer into a slim and attractive chassis Combining the MEDPC 5800 into your system can achieve both cost saving and efficient improvements in common applications including Surgical Radiology LIS Lab Information Systems and Electronic Medical Record The MEDPC 5800 is definitely your perfect choice MED PC MEDPC 5800 1 2 Feature Intel Core i7 i3 Celeron Dual Core Processor Intel QM77 Chipset Multiple display output support Fanless easy clean design Compact Size 1 3 Specification Hardware Specifications CPU Intel CoreTM i7 i3 Celeron Dual Core Processor Disk Drive Space 2 5 Hard Disk Drive Solid State Drive Function Key Power On 1 x Isolated RS 232 port 4 x RS 233 ports optional 1 x Isolated USB 2 0 port 4 x USB 2 0 ports 2 x USB 3 0 ports 2 x Isolated Gigabit LAN
12. egistered trademarks of Intel Corporation IBM PC AT PS 2 are trademarks of International Business Machines Corporation Microsoft Windows is a registered trademark of Microsoft Corporation RTL is a trademark of Realtek Semi Conductor Co Ltd C amp T is a trademark of Chips and Technologies Inc UMC is a trademark of United Microelectronics Corporation ITE is a trademark of Integrated Technology Express Inc SiS is a trademark of Silicon Integrated Systems Corp VIA is a trademark of VIA Technology Inc espective owners MED PC MEDPC 5800 Packing List Before vou begin installing vour Medical Station please make sure that the following items have been shipped MEDPG 5800 Medical PC Wall Mount Bracket m Utility DVD ROM which contains User Manual in PDF format and Drivers If any of these items are missing or damaged you should contact your distributor or sales representative immediately Headquarters Onyx Healthcare Inc 2F No 135 Lane 235 Pao Chiao Rd Hsin Tien City Taipei 231 Taiwan R O C TEL 886 2 8919 2188 FAX 886 2 8919 1699 E mail sales onyx healthcare com http www onyx healthcare com MED PC MEDPC 5800 Worldwide Offices Onvx Healthcare USA Inc 2663 Saturn street Brea CA 92821 USA Tel 1 714 996 1800 Fax 1 714 996 1811 Email usasales onyx healthcare com Onyx Healthcare EUROPE B V Ekkersrijt 4002 5692 DA Son The Netherlands Tel
13. ion the function of this port becomes Front Speaker Out 9 Kensington Lock MED PC MEDPC 5800 10 POTENTIAL EQUALIZATION CONDUCTOR The purpose of additional potential equalization is to equalize potentials between different metal parts that can be touched simultaneousiv or to reduce differences of potential which can occur during operation between the bodies of medical electrical devices and conductive parts of other objects The connector is speciallv shaped so as to prevent chance disconnection when used as intended while allowing the lead to be removed without the need for tools 2 6 Mounting Kit assembly You can easy to assembly the mounting kit by each 4 screws as below and the following types of screws are recommended Assembly 4 screws MED PC MEDPC 5800 Interior Screw spec used for screw on the Unit 5 30mm 0 25 0 25 1 10mm 0 25 0 25 Mrd Exterior Screw spec used for screw on the wall or any shelf LEERME D 6 80mm 0 25 0 25 2 BAMAR H 2 60mm 0 25 0 25 SERBIE d IM4XPO ARAF AARRE L 8 00mm 0 40 0 40 sit MM jik uncon MED PC MEDPC 5800 Chapter Driver Installation eo MED PC MEDPC 5800 There are several installation wavs depending on the driver package under different Operating Svstems Please follow the sequence below to install the drivers 3 1 Installation Insert the MEDPC 5800 DVD into the DV
14. ter equipments need the maintenance or are bevond repair we strongly recommended that you should inform us as soon as possible for the suitable solution For the computers that are no longer useful or work well please contact with worldwide distributors for recycling The worldwide distributors show on the following website http www onyx healthcare com tw Contact php Note Follow the national requirement to dispose unit
Download Pdf Manuals
Related Search
Related Contents
- Rockwell Automation Philips Headband headphones SHL5002 NATURAL revista direito animal 8_virtual.indb 004. PROVA OBJETIVA - Amazon Web Services Alba i-mode ug_de.vp FAQs : Analyseurs NomaSense O2 Origin Storage 750GB TLC SATA 2.5" France Brevets: a state-owned patent troll, harmful Copyright © All rights reserved.