1. to electromagnetic disturbances may cause unstable or inaccurate heart rate readings These may occur near high voltage power lines traffic lights overhead lines of electric railways electric bus lines or trams televisions car motors bike computers some motor driven exercise equipment cellular phones or when you walk through electric security gates Metete emay u rN Every time the unit receives a signal it starts a new activity record and begins to store heart rate data The LED indicator will flash green every 3 seconds to indicate data is being received As soon as the unit stops receiving data or is turned off the activity record is ended To end an activity record turn unit OFF 1 Press and hold BUTTON for 2 seconds The LED will turn amber 2 Release BUTTON to turn OFF NOTE The unit will automatically deactivate if no heart rate is detected for 5 minutes during this time the LED will continue to flash green The unit will also deactivate if the battery is low or if the memory is full The data logger can record up to 30 hours at a storage interval of 2 seconds Up to 99 activity records can be stored LED SIGNAL MEANING RED flashes slowly during exercise 90 of memory full RED steady for 2 seconds Memory full the unit will automatically turn OFF Memory records can be deleted manually or by using the SmartSync PC software supplied with this product To delete using your PC please refer
2. to the software Help file To manually delete all activity records 1 Press and hold BUTTON for 4 seconds when unit is OFF The LED will flash amber 2 Press again to clear memory 3 The LED will turn green for 1 second to indicate records are deleted TIP To maximise the product lifetime we recommend waiting until the memory is nearly full before uploading the data to your PC CONNECTING TO YOUR PC To connect to your PC insert the USB cable into your PC and LR yt attach to the Heart Rate Logger RESET To reset use a thin blunt object to press RESET PRECAUTIONS This product is engineered to give you years of satisfactory service if you handle it carefully Here are a few precautions Do not subject the unit to excessive force shock dust temperature or humidity which may result in malfunction shorter electronic life span damaged battery and distorted parts Donot immerse the unit in water If you spill liquid over it dry it immediately with a soft lint free cloth Do not clean the unit with abrasive or corrosive materials Do not tamper with the unit s internal components Doing so will invalidate the warranty on the unit and may cause unnecessary damage The unit contains no user serviceable parts Only use fresh batteries as specified in the user s instructions Do not mix new and old batteries Due to printing limitations the displays shown in this manual may differ f
3. OreGcon SMART SYNC Universal Wireless Heart Rate Data Logger with PC Download Model WM100 USER MANUAL INTRODUCTION Thank you for selecting this Oregon Scientific Heart Rate Logger for your sports and exercise needs This product allows you to record your heart rate information from your chest belt and download it to your PC Please keep this manual handy as you use your new product It contains practical step by step instructions as well as technical specifications and warnings you should know IMPORTANT The measurement functions built into the WM100 are not meant to substitute professional measurement or industrial precision devices Values produced by this unit should be considered as reasonable representations only OVERVIEW Q 1 1 LED indicator 2 BUTTON 1 3 2 4 1 Battery compartment 2 Reset hole 3 Belt clip 4 USB cable connection socket GETTING STARTED The unit is supplied with a CR2032 cell battery The LED indicator will flash red for two seconds before the unit turns off to indicate the battery is low To change the battery 1 Slide the belt clip off the unit 2 Use a screwdriver to remove the battery compartment cover 3 Replace the battery matching the polarity as shown 4 Reattach the battery compartment cover WM100_M_USA_OP indd 1 Ze SENN Set up your chest belt 2 Press BUTTON to power on the unit and place it next to your ches
4. onal inquiries please visit www2 oregonscientific com about international asp EU DECLARATION OF CONFORMITY Hereby Oregon Scientific declares that this Universal Wireless Heart Rate Data Logger WM100 is in compliance with EMC directive 89 336 CE A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service cE 2006 Oregon Scientific All rights reserved 086L004464 037 5 4 06 12 18 51 PM
5. rom the actual display The contents of this manual may not be reproduced without the permission of the manufacturer Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice SPECIFICATIONS TYPE DESCRIPTION LxWxH 46 x 46x 17mm 1 8 x 1 8 x 0 7 in Reception range 10 cm 4 in signal search 80 cm 31 5 in signal found Signal reception 5 3 kHz digital analogue Memory 30 hrs at 2 sec intervals 99 activity records Power 1 x CR2032 cell battery ABOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about Oregon Scientific products such as digital cameras MP3 players children s electronic learning products and games projection clocks health and fitness gear weather stations and digital and conference phones The website also includes contact information for our Customer Care department in case you need to reach us as well as frequently asked questions and customer downloads We hope you will find all the information you need on our website however if you re in the US and would like to contact the Oregon Scientific Customer Care department directly please visit http www2 oregonscientific com service default asp OR Call 1 800 853 8883 For internati
6. t belt to enable data reception 3 Attach the unit to your belt or place it in your pocket Start exercising 4 To end data logging press and hold BUTTON for two seconds until the LED flashes amber then release NOTE The unit has a range of 10cm 4 in during signal search and 80 cm 31 5 in once a signal has been received Before using for the first time please install the software and connect to your PC to upload time and date information CONNECTING TO CHEST BELT This product is compatible with heart rate chest belts transmitting digital or analogue signals on 5 3kHz such as the chest belts supplied with the following models SE102 SE200 SE211 SE212 SE232 SE233 Please check your chest belt user manual for more information or visit www2 oregonscientific com The unit will automatically search for a signal whenever you power ON the unit The LED indicator will signal connection status LED SIGNAL MEANING GREEN flashes quickly Searching for signal GREEN for 3 seconds Signal found AMBER for 3 seconds No signal found GREEN flashes slowly Device activated NOTE If no signal is found after 10 seconds the unit will power OFF If you change or reset your chest belt during an exercise session it may be necessary to search for the signal again To force a signal search Press and hold BUTTON for 4 seconds and release when unit is ON WARNING Signal interference in the environment due

Download Pdf Manuals

image

Related Search

Related Contents

新しい消費生活用製品安全法について (パンフレット PDFファイル A4:19  Trust SC-5500p  Instruction Manual - Zewa Medical Technology  Organisation de Coopération et de Développement Economiques  NEXO AVIU 4.12 Conexión con Aplicaciones NEXO  Manual de Instruções  Easy-Move - tutti i negozi  Politique et Instructions Nestlé pour la Mise en Œuvre du Code  Yarway Level Gauges, Electronic Level Gauges  BENDIX BW1570 User's Manual  