Home
Advantys STB Distributed I/O Solution
Contents
1. Configuration J Imprimer dans un fichier Ander Printing selection of islands and items to be inserted in the design report 48326 EN_Ver4 0 indd Advantys STB Distributed I O Solution Configuration and debugging software Export of user labels tags The Advantys software allows you to create labels symbol names for all objects and I O parameters of the Advantys STB configuration The File export function exports these names at the same time as the mapping regardless of the fieldbus or network used This information is directly usable on all controllers This means you do not have to declare I O objects all over again and promotes consistency in the naming of machinery or equipment items import export of island mapping files This function allows you to carry out mapping and export it in the format of any PLC programming software regardless of the fieldbus or network Printing of design report This function allows you to select topics to be sent to a printer or to a PDF or editable RTF file The following items can be selected mg Graphic image of the island See example above m All or part of the information of the island o List of mandatory components including accessories such as bases connectors etc List of optional components such as labels keying pins memory cards etc Information about the workspace Information about the island Image of the island List of co
2. Solution Configuration and debugging software Module Editor The editor gives access to 4 tabs depending on the way in which the island is connected to the network or fieldbus General Properties I O Image and Diagnostics General tab This read only tab island online or offline provides general information and displays the key technical characteristics of the selected module Properties tab This tab accessible when the island is offline contains the operating settings for the selected module some of which can be changed by the user Among other things you can m Select the display format for parameters decimal or hexadecimal m Identify a module as mandatory That module is then designated as critical for island operations If the module fails or is not present the island will no longer be operational it will stop m Declare the scanning priority for the digital input module This allows you to assign more frequent scanning to modules regarded as fast up to 10 modules per island compared with other modules m Module configuration The configurable items cells with white backgrounds depend on the type of I O module Depending on the type of module the main parameters are o user label assignment free text field for up to 50 characters 7 o digital input modules filter time and choice of positive or negative logic for each channel o digital output modules the behavior upon short ci
3. and debugging software The reflex functions work directly at the level of the island output modules so that they are not taken into account or processed by the island s master device These reflex functions can be associated with priority I O modules to ensure reliable response times An Advantys STB island can call up to 10 reflex functions These functions are created from blocks whose inputs are activated by digital or analog input channels and whose results activate a digital or analog output channel You can nest two reflex functions Reflex types and function blocks Various types of function blocks are available Boolean logic function blocks XOR block AND blocks with 3 inputs and 1 output enable i operational input 4 i operational input z y ii operational input 3 y ii Rising falling edge counting function blocks on rising or falling edge from 0 to 65 535 enable t falling edge counter count input gae counter preset p counter direction reset Digital Latch function blocks on state 0 or 1 or on rising or falling edge memorize state 0 or 1 p enable latch trigger digital latch on falling operational input M tput m edge ee analog input ii Timer monostable blocks when working when idle upon activation and upon deactivation enable delay to start timer timer trigger time unit x
4. terminal count reset ir Compare function blocks on signed integers 32 768 to 32 767 i lt i gt lt i gt i lt andi gt enable p i outside the window compare _ pa output operational input we threshold 1 A ra 2 A Analog Latch function blocks on state 0 or 1 or on rising or falling edge memorize the signed integer 0 to 65 535 or unsigned integer 32 768 to 32 767 P enable latch trigger high level analog latch output p Documentation A Reflex actions document is supplied on the CD ROM STB SUS 8800 and on our website www telemecanique com 48326 EN_Ver4 0 indd Catalog numbers Advantys STB Distributed I O Solution Configuration and debugging software The Advantys STB distributed I O configuration and debugging software is multilingual and compatible with the operating systems Windows 98 Second Edition Windows NT 4 0 Service Pack 2 6 Windows 2000 Service Pack 2 1 and Windows XP Service Pack 2 1 Online help is available in 5 languages English French German Spanish and Italian Internet Explorer version 4 0 or higher is required to access the on line help Description Use Catalognumber Weight kg Advantys configuration and Single station 1 workstation STB SPU 1000 debugging software Includes a cable and a CD ROM STB SPU 1666 3 stations STB SPU 1003 Includes 3 cables and 3 CD ROMs 10 stations STB SPU 1011 Includes 10 cables a
5. Presentation Advantys STB Distributed I O Solution Configuration and debugging software Advantys STB SPU 1 e e software is a tool for configuring and debugging the range of distributed I O solutions Advantys STB OTB IP20 protection and FTB FTM IP67 protection It also allows debugging and diagnosis of distributed I O islands while in operation As far as the Advantys STB range is concerned Advantys STB SPU 1 ee software can be used to m Define all O modules which go to make up an Advantys STB automation island m Configure standard type modules basic modules have a fixed default configuration m Configure the reflex functions handled at the island level m Optimize island performance by assigning priorities for the processing of certain modules m Declare certain modules to be mandatory i e modules whose presence and correct operation are required for the island to operate correctly m Declare external CANopen devices in the island such as Advantys FTB IP67 monobloc I O splitter boxes Festo or Parker electropneumatic valves ATV variable speed drives other CANopen V4 0 devices etc m Check the configuration for compliance and power consumption User interface The main screen of the Advantys configuration and debugging application provides easy and intuitive access to all the available tools by Suchet Caa l j 4 irn Edin ahe et Enie Upton Feie sige al RUOTE Ske Te tome loo G ra j enr jol
6. ecacecea Mawtgatcun feapece de Irmi F A SIBER YID 5 A STESEN Y1 A GTER lt 0 W cen aa paara Ae H srearzzi2 v 017 ST BMAP 2212 010 Fors BTBCPSe111 1 0 A STEPOTZIO W 1 0 A STEPDTINO 1 0 i fl pargi BT ROMP W 175 BT EOMITZ20 Y 75 BT BDOAES0 1 8 STROOD 41 8 ST BOCABETO 1 0 ei FA Cepheid ST BDSM BETO 01 88 ara Labi Mil E myi Conkgunabor ox Lagarde Bocce Bete Olr EB sistent a O a O Oo Ooo 6 z g Ooo Ooo Ss ass an 7 30 STREP RPGs PREETI idh STREET aTEOOTS a w 1 E pis w 1 gies W 4 6 2H W141 hhh Yi m m m Capiecar dici jen me mr Legigue O segta mr ictima 8 D A A Dita HDE Source tpat Tropa D5 4 Deacuni pcd a H This main screen contains a general view comprising several windows and toolbars that can be moved about the screen 1 Menu bar giving access to all functions 2 Toolbar containing icons used for direct access to editors and the most frequently used functions 3 Browser for browsing the various islands and segments of each island 4 Main window for viewing islands and segments By selecting a module you can access the appropriate editors O Module Editor o Reflex Action Editor o Power supply and memory resource analysis o Overview of the I O image o Diagnostics The last two items are available only if the island is online 5 Catalog browser for all the Advantys STB components sorted by category networks power supply digita
7. l I O etc 6 Power supply and memory resource analysis window 7 Log window displaying the results of operations performed by the configuration software during a work session on an island 8 Status bar 48326 EN_Ver4 0 indd Functions amp STARDOA2 OCF Aad i Logement jD de meee 027 102 ininal Propestts rki ia be neces Hondu morula STHHOo Gods KTE ANITA Horidu arema T ehrercereq Wome J Hisa Ji Desonpeorr hn S78 HCI HHI c ansrok maraca rrid bor Copan lender vero The reda can drea upto 30 LU redaz oe ta fhe rreri IA mde aitekin EN K PL ea 125 mst ta HH wordt 13 maki frre 1250 pred PLC h HI mk J kenai ree LD neediest bes pa cnet i ee alya Blick di race Aiks de inkonsbors Donde gira ur be de Hri CANopen bus interface NIM module ithe STRAO0 1510 155 Amt 2 Logement 4 ID de encod A Ay Bks hi reeks Endre k Mess nikpi STB ACO1210 module with 2 analog output channels u ce A STEHCUZZIZ WV L31 K 1 Logimini 110 de ma 1A AAAF M Herdina ID de roeud max rurFesterwion CANoperc 22 H Giria Propria 5 Hen du pararrebize E Adina Into Stone Let Eps mp vod MMl_lo_ PLI Ret noe Ponds PLC 1o HMI bade du module ok ame iene Eris ba kabi uitae STB NCO 2212 CANopen bus interface module A10 Image Overvicw Fishl_un in ays odors Imig I O Image tab 48326 EN_Ver4 0 indd Advantys STB Distributed I O
8. mponents Fieldbus I O image Modbus I O image Reflex actions Use of resources Details of resource power supply Details of resource configuration Details of modules Notes OOOHOAAAAAAAoOD Test mode There are two test modes m PLC offline test Bus or network communication is disconnected The outputs can be controlled directly from the Advantys application connected via the Modbus socket of the NIM module m Online test Bus or network communication is operational The outputs can be forced directly from the Advantys application This mode can be accessed by entering a configurable password These test modes allow import of the island configuration or let you read error messages and I O states Update at www telemecanique com The Advantys STB SPU 1eee configuration and debugging software and the module catalog database are available online at web www telemecanique com Here you can m download the Advantys STB SPU 1000 software for a free 21 day trial period m for officially registered software obtain all updates for functions and the catalog of components that can be connected to Advantys STB automation islands 5 Functions continued Advantys STB Distributed I O Solution Configuration and debugging software Reflex Functions Editor For applications requiring short response times lt 3 ms the Advantys STB Distributed I O Solution allows you to create reflex functions using the configuration
9. nd 10 CD ROMs 10 workstations on one site STB SPU 1100 Unlimited registration capacity Includes 10 cables and 10 CD ROMs Subscription to Advantys 1 workstation STB BBS 1000 configuration and debugging software 3 stations STB BBS 1003 Duration 1 year 10 stations STB BBS 1011 10 workstations on one site STB BBS 1100 Unlimited registration capacity Documentation User documentation 1 Multilingual on CD ROM STB SUS 8800 Replacement parts Connection cable from PC Length 2m STB XCA 4002 to network interface module Catalog numbers Alliance SI program Description Use Catalog number Weight kg Advantys configuration and 10 workstations on one site STB SPU 1010 debugging software for a member of the Alliance SI program Includes 10 cables and 10 CD ROMs Subscription to Advantys 10 workstations on one site STB BBS 1010 configuration and for a member of the Alliance debugging software SI program Duration 1 year 1 2 lots of documentation are available on the CD ROM STB SUS 8800 and on our website www telemecanique com Advantys configuration and debugging software Quick start up guide Advantys configuration and debugging software User manual 48326 EN_Ver4 0 indd 7
10. rcuit or overload manual or automatic reset the choice of positive or negative logic for each channel the default fallback position for each channel 0 or 1 state o analog input modules with the offset and scaling for each channel o analog output modules with the refresh rate and the default fallback position hold the value or assume a predefined value for each channel o application specific modules for TeSys Quickfit or TeSys U motor starters the choice of positive or negative logic for each channel the behavior upon short circuit or overload manual or automatic reset and the default fallback position for each channel 0 or 1 state O counter module the definition of the counting function and its operation see page 48323 2 o network interface modules the amount of memory reserved for data exchanges with the Operator Terminal directly connected to the network interface module This data is also accessible by the island s master device If an Advantys STB island has a CANopen extension a parameter allows you to define the address of the last standard CANopen device connected to the island Online help for the selected module can be displayed to show the limits and operating values of these parameters I O Image tab This tab accessible when the island is online provides a table with data concerning the E input output modules comprising the Advantys STB island values and state of each module m Operator Te
11. re the Advantys configuration and debugging software resides Analysis of the island s memory and power resources At any time during the configuration process you can consult the following information expressed as a percentage m The power consumption at various voltages o the 5 V logic voltage provided by the STB Nee network interface module O the 5 V logic voltage provided by the STB XBE 1200 BOS extension module O the 5 V logic voltage provided by the STB CPS 2111 auxiliary power supply o the 24 V voltage provided by the STB PDT 3100 3105 power distribution module s o the 115 230 V voltages provided by the STB PDT 2100 2105 power distribution module s m The usage of the memory integrated in the network interface module o image field for inputs and outputs O settings field for the island configuration data and reflex functions o field dedicated to operator dialog Downloading configuration data The software enables bi directional transfer of configuration data m From the PC to the RAM and Flash memory of the island network interface module in order to make the island operational If the network interface module includes the STB XMP 4440 32 KB removable memory card data is written to the card providing a backup m From the NIM interface module to the PC Run time parameters RTP The RTP Run Time Parameters function allows access from the PLC to all the data 1 of external CANopen components connec
12. rminal connected to the network interface module The length of this field defined in the Properties tab of the network interface module equals the maximum total size of the image table less the words occupied by the image of the I O modules The total size of the I O image table depends on the type of the network interface module These I O images can be displayed in two views m Field bus or network view each protocol transfers its data in a specific format E Internal island bus view the Modbus protocol is used 1 A utility allowing the export of user labels under CANopen to the Premium PLC memory under Unity Pro or PL7 is available Please consult your Regional Sales Office 3 Functions continued oO Occup e Bl Depeetie C Avent TENMP2212 STBPOT3100 STEPOTI100 STBPOT2100 v 0 10 1 1 Vv 1 0 1 2 V 1 0 4 2 Vv 1 0 1 9 V 1 0 1 9 V 1 56 1 1 V 1 56 1 1 127 Capteur l fa fx TT o leo aiga Coo i aiye Die s i SECM SRT FE tE O eang Hag AR Access via RTP to external components such as ATV variable speed drives etc ET avanir ute TE E g TEET Ti E ile les E DOM T T Absent modules will be actually installed if needed Advantys STB Distributed I O Solution Configuration and debugging software Diagnostics tab This tab allows the user to perform diagnostics for the island connected to the PC terminal whe
13. ted to an STB island The 2 main uses are m Writing the parameters of a component FDR Faulty Device Replacement operation m Reading all variables for surveillance and diagnosis of any object connected to the island Absent modules This function of the Advantys STB SPU 1eee configuration and debugging software alows you to declare I O modules which to begin with are not actually included in the island This means that m virtual module slots are reserved in the island configuration m the exchange data of the virtual modules are included in the tables of exchanges with the PLC The physical modules can be integrated into the automation island as and when real needs dictate 1 Data configuration and adjustment parameters and variables 48326 EN_Ver4 0 indd Functions continued Imprimer TestD2 Imprimante so litaire en local Imprimer SEISISEISIGIS Seggeeeneeney Seeeteecees lot actif C llots s lectionn s Imprimer les l ments M Informations sur l espace de travail M Informations sur l lot MV Image d E S de bus terrain M Image d E S Modbus M Actions r flexes M Utilisation des ressources M D tails d alimentation de ressource V D tails de configuration de ressource V D tails sur les modules a Annotations IV S lectionner tout Copies Nombre de copies fi MV Assembler Apercu avant impression
Download Pdf Manuals
Related Search
Related Contents
Allegato 4 - Capitolato Tecnico Manual en PDF - Sloting Plus Affiliate Pro – User Manual 1 Version: 1.1 Website: http://www.mage Samsung Galaxy Tab 3 (10.1, 3G) User Manual Omron Healthcare MC-110 User's Manual Pioneer DV-LX50 User's Manual 7月23日 17:00(必着) - 長崎県出納局物品管理室へようこそ ŠKODA Octavia MANUAL DE INSTRUÇÕES Manuel d`utilisation Copyright © All rights reserved.