Home
gtc812 configuration software user manual
Contents
1. System Timers Test Time h 4 30 Test Period i Days 0 disabled Entry Delay cg g Set Module Cleck PC time O2 07 2012 10 47 34 WETE f 20 Read Module Clock Module time Reset Module b Fig 20 Explanation of fields of Main Window It is installer password comprised of 6 symbols when the module is being configured via SMS messages See INST codes table It is installer password comprised of 6 symbols each time the module is being controlled via SMS messages See USER code table Temperature It is temperature scale Two scale types are possible one of which may be selected after scrolling menu near the note Temperature e Celsius temperature indications according to Celsius scale e Fahrenheit temperature indications according to Fahrenheit scale ARM DISARM method Touch input When connecting the module to the central lock it is necessary to set signals the module will enter ARM DISARM modes 5 versions is possible e Disable programmable block of LOCK and UNLOCK inputs The module will show no reaction towards signals in LOCK and UNLOCK inputs gt 500ms Positive Pulse On Touch input If in input Touch gt 500ms the impulse will appear into V the security system s state will be changed from ARM to DISARM or wise versa gt 500ms Negative Pulse On Touch input If in input Touch gt 500ms the impulse will appear into V the security system s state will be changed from ARM to DI
2. In order to open Window Outputs it is necessary to select Outputs option Outputs D Mame Out ONSMStext Out OFF SMStext Out defintion Out pulse time State Mode Pa Outi cuti ON Outi OFF CTRLISMSDIAL 158 Pulse 2 Out Out20N Gut OFF SIREN 600s Iv Steady 3 Outs outson Gut3 OFF ARM state 600s Steady 4 outa outaon Guid OFF Light Flash 600s Steady E Fig 25 D Name Out ON SMStext Cut OFF SMS text Out definition X Out pulse time State Mode CE Otd OFF aoisi E 2 Ouz outzon Out2 OFF LL 600s a Steady SIREN 3 Out outsonN Out3 OFF eee 600 E Steady 4 Out4 Out4 ON l Out4 OFF ARK state BOUs E Steady Inputs OK Light Flash DISARM state El Fig 26 nE Out OFF CTRLUSMS DIAL E 2 Out OFF CTRUSMS DIAL E A 3 Outs Outs ON l Outa OFF CTRLS MS DIAL 00s m GN A 4 Out4 Ot on t4 OFF CTRLSMSDIAL BOOS E Steady Ei Fig 27 Explanation of fields of Outputs Window PI Output Dumber SS O It is a text which will be sent to a user after activation of output by the module This text may be changed Out OFF text It is a text which will be sent to a user after deactivation of output by the module This text may be changed Out definition Output activity algorithm may be selected from scrolled menu seeFig 26 Software SERA for the GTC812 module www topkodas It 21 CTRL SMS DIAL output will be possible to control via SMS message short call or commutation via selected input This algorithm may
3. Found New Hardware Wizard Please wait while the wizard installs the software__ B USE Serial Config Usbser sys To CAWINOOMWS eustemse DRIVERS 4 Back Herts Eancel Wait while the driver will be installed Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for USB Seral Converter Click Finish to close the wizard Fig 8 Displayed Window fig 8 means that your PC has found file necessary for driver s installation and successfully installed it Press Finish Installation of USB Serial Config is finished Software SERA for the GTC812 module www topkodas It lox File Action view Help Gigoie ai Be BH Realtek RTL169 8110 Family Gigabit Ethernet NIC ai 4 Other devices z Gy Modem Device on High Definition Audio Bus ay Ports COM amp LPT oe YP BT Port COM10 oo SS BT Port COM11 oo SS BT Port COM12 oo BT Port COM13 a AY BT Port COM14 oo SS BT Port COMZD oo BT Port COM2Z1 oo SS BT Port COM40 oo SS BT Port COM41 oo BT Port COM42 oo YF BT Port COM43 oo 4g BT Port COMB i aw BT Port rt COM oy oh Processors HA Secure Digital host controllers W System devices F Sound video and aame controllers x Open Device Manager window and in the row COM amp LPT press in order to see all PC COM ports The row should show USB Serial Config COMx Drag mouse cursor on this row an
4. successful installation of the software SERA press Finish in the displayed WindowFig 4 Congratulations you have successfully installed the application SERA in your PC 2 USB drivers installation In order to configure the module via USB interface it is necessary to install USB DRIVER Drive configuration is available in the file usbser inf After connection of USB cable the module must be supplied with 12V to the PC via USB interface OS Windows will find USB driver Driver configuration Winows 2000 XP usbser inf Windows 7 x86 or x64 usbser_x86_x64 inf Found Hew Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for curent and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Can Windows connect to Windows Update to search for software O Yes this time only es now and every time connect a device No not this time Click Next to continue Fig 5 Select No not this time in the displayed Window Fig 5 and press Next gt Software SERA for the GTC812 module www topkodas lt 4 Hardware Update Wizard Welcome to the Hardware Update Wizard This wizard helps you install software for USB Serial If your hardware came with an installation CD lt o floppy disk insert it now Wi hat do you want the wizard to do Install the software automaticall
5. 4 On Off SIM card If note READY is visible it means that SIM card is fully functioning Otherwise check whether PIN code request is off or replace SIM card Signal level Signal strength of GSM communication Registration State of GSM modem registration to GSM network SMS Service Centre SMS centre number This number should be checked if it is Address correct If this number is incorrect SMS messaging may be impossible This number may be changed after inserting SIM card into any mobile phone Power supply voltage the module is connected to Nearby number is value of ADC voltage When multiplying this number by the coefficient Fig 33 voltage value V will be achieved Temperature of temperature sensor The number nearby is temperature ADC value used to calculate temperature according to the formula Temperature X ADC Y X and Y coefficients may be changed in temperature window in order to additionally calibrate temperature measuring To review these coefficients refer Fig 36 After performing additional calibration it is possible to achieve a very accurate temperature measurement up to 0 1 C in a narrow temperature measurement range ARM Indication that at the moment the module 1s in ARM ARM mode DISARM that at the moment the module is in DISARM WAITING ARM Module mode when Exit Delay time is being calculated After pressing the button ARM DISARM mode should be changed Pressing this button starts testing of the module Press
6. O O O C E pE oooooooooooa O O O C E Ei cooooooooooo O O O C E E oooacooocoooa O O O C E DE ooooooooooo O O O C E fio ooooooooooo O O O C E f1 cooooooooooo O O O C O J12 cooooooooooo O O O C E FE ooooooooooo O O O C O BEE oooacooocooon O O O C E ERE cooooooooooo O O O C E Jae cooooooooooo O O O C E Bi cooooooooooo OO O O C E 18 oooooooocoooa O O O C C fais oooacooocooo O O O C E 20 cooooooooooo OO O O C E H Fig 24 Explanation of fields of Remote Control by Dialling ID number of a user who is able to control the module by dialling up to 400 User Phone Telephone numbers of users who will be able to control the module by dialling should be entered in this column User number should be entered with international code iButton iButton Maxim iButton key DS1990A 64 Bit ID code The code might be entered manually or automatically registered upon entering the module into keys learning mode In order to delete the code enter 000000000000 OUT1 OUT2 OUT3 O0OUT4 Where the check boxes are checked these inputs will be switched if a user will call from this number Preferred output may be assigned to each user s number Thus different users are able to control different objects ARM DISARM command If this check box is checked a user will be able to ARM DISARM the security system by short call to the module Software SERA for the GTC812 module www topkodas It 20 5 4 Window Outputs
7. SARM or wise versa Positive Level ARM Negative Level DISARM On Touch input When in input Touch is a Software SERA for the GTC812 module www topkodas It 15 positive level V the state of the module will be ARM When negative level V the state of the module will be DISARM Positive Level ARM Negative Level DISARM On Touch input When in input Touch is a positive level V the state of the module will be ARM When negative level V the state of the module will be DISARM iButton Access ID On Touch Input uses Touch input System state ARM DISARM is changed by using Dalass Maxim iButton key iButton DS1990A 64 Bit ID Learn iButtons After pressing this button the module will enter iButton keys associating mode In this mode the module will enter into memory all touched keys which will be able to control the module Stop Learning button Upon pressing the button the mode for new iButton keys learning will be stopped and at the same time the program will automatically read the codes of newly learned keys To review the codes of these keys refer menu USERS amp Remote Control see 5 3 chapter Test time The time period since which informational SMS text message will be sent Attention In order to timely send the periodical test message it is necessary to adjust settings of internal clock of the module Test Period Test sending periodicity in 24 hours Entry Delay Input time in seconds The system start
8. Topkodas gt SERA GTC812 configuration and testing software in Microsoft Windows environment User s guide SERA Configuration Software GTC12 configuration oO x File Settings Devices Update About Jal eal Sa el System Settings p System Options H GSM Communications atemis ct GSM Alarm Security System Access Control Temperature Controller ardware details ae bitti Event 5M3 Text Installer Password 6 symbols E gue reARM HA Tce aw 7 Custom SMS Test es W Siren Peep on ARMDISARM Boot GTC812boot_1vO Temperature Controller User Password 6 symbols I Zone Auto Bypass PMA TCE 21 20626 Testing and Diagnostic Temperature Scale Celcius ARMIDIS ARM hethod Disable Learn iButtons Stop Learning f 4 30 Test Period f Days O dizabled Entry Delay 5s Bip E Set Module Clack PC time 27 06 2012 14 39 52 Siren Time 120 5 Read Module Clock Module time Reset Module GTcaiz _ COMB is closed Firmware file have been loaded lesse memmen eee eee eden bse a rae See user manuals For details TOME Disconnected aTc812v120626 Content t AS CaO GE SERA COU Ie ceca ert cue execs evecey ctisees EEEE 2 2 USB GAY en a e E E EE E S esdiaeteaetovseans 4 OCI UT e ee E E E E E E E E E 10 A Conicctonolthemodule 10 yout PC sesers e E E 12 WV Om viie SOME a8 Se RA soea e a Eaa OE E Ia Eee 12 5 1 Contentof the module COMIC UT AON 4253 eccossasesaSeettayeoseqsans
9. anic Button Panic Button ia EOL silent 200m 1s Disable Tamper Alarm Tamper Restore ri m EOL 24 hours 200m 13 Disable Low Battery Batery Restore ri M Mc silent 65000ms 6000s Disable n Low Battery parameters Alarm voltage f Y Calibration 2 28783 Restore voltage 136 r Fig 33 Software SERA for the GTC812 module www topkodas It 5 6 Window Event SMS Text In order to open Service Text Summary window it is necessary to select the item Event SMS Text from the content Service text summary Jo Module ARM System ARAM Module DISARM System DISARM Module reset System reset fone Auto Bypass ALto By pass Module Periodical Test Test Report 41 41 41 lt 1 41 KI Module STAY ARM Armed STAY Fig 34 Explanation of fields of Service text summary window Name of Status Event Event Text Event test which may be changed If the check box is checked the message about a certain event will be sent to a user if it is configured in Communications window 5 7 Window Text summary In order to open Text summary window select Text table Fig 35 from the left side of the Window This Window is intended for creation of equivalents 1 Events Event 2 GSM Signal strength Signal strength 3 Module voltage System voltage 4 Output state Outout state 5 Mev passyvord Mev password a B System state System into Rz Fig 35 Explanation of fields of Text summary Window PID Textnumber O O Text in Engl
10. be used for ignition blocking for gate control or for remoter starting of a car etc SIREN output used for connection of siren Used for generating of voice signal in the event of alarm BUZER sound signalling device Upon alarm of the zone beeps continuously When security system starts calculating exit delay the user is able to hear short repetitive sound signals When 10 seconds are left till the begging of activation signals are being repeated each 0 5 seconds If after expiry of the delay time all zones remain unalarmed the system turns into ARM state along with beep sound to confirm the action ARM State state of alarm system ARM DISARM It may be used for light indication When the output is set to operate in pulse mode this feature may be used to close car windows or sunroof on arming Impulse time should be set 20 30 seconds On arming the output will generate signal to close windows Inputs OK if any of zones is disturbed the output will be activated This feature is usually used for indication whether all zones are in order Light Flash used for connection of light signal Upon alarm of the security system the light starts blinking Lights will also blink when arming disarming the security system This feature may be applied to connect car direction signals DISARM State the output will be activated only if the system has been turned off Out pulse time It is time in seconds which indicates du
11. d right click on the menu item Properties You should see the window below with the note This device is working properly This means that PC is successfully prepared for operation with configuration testing application SERA USB Serial Config COM Properties x General Fort Settings Driver Details USB Serial Config COM Device type Ports LOM amp LPT Manufacturer USEContig Location Location U USE Serial Device status This device is enei Arapeti IF you are having probleme with this device click Troubleshoot to start the troubleshooter E Device usage Use this device enable a OK Cancel Software SERA for the GTC812 module www topkodas It 9 3 COM port number setting After installing drivers you should check what COM port number has been assigned to the USB module To perform this task in Windows environment follow the instructions mentioned below AN Attention The module should be connected to 12V and to a PC via USB interface The module and the PC should have ground connection because absence of the ground connection between the power source of the module and the PC may damage the module Open the Window System Properties path Start gt Control Panel gt System System Properties Window Fig 9 is being displayed From the Window System properties select the tab Hardware After selection of the tab Hardware Window Fig 9 will be disp
12. ead Configuration icon f Attention Each time after configuring the module press File gt Write Device or press Send Configuration icon Fig 18 thus the software SERA will write configuration changes into the module SERA Glauto configuration File Edit Setup Devices Update Help Send Confi guration Sial ela alaf e GTauto Configuration Fig 18 Send Configuration icon 5 1 Content of the module configuration System Options GSM Communications USERS8Remote Control Temperature Controller Testing and Diagnostic Fig 19 Configuration content is available at the side of the screen To open configuration window according to selected content menu click preferred part of the content Software SERA for the GTC812 module www topkodas lt 14 5 2 Main Window of the software SERA System options Main Window System Option of the software SERA is displayed in Fig Fig 20 This Window is displayed automatically when the GT C812 device is selected Devices gt GT C812 It also may be selected from the content of the module GSM Alarm System Access Control Temperature Controller ardvare details Installer Password ioe 6 symbols E Ado eI HA GTCS 2v1 ee Iv Siren Peep on SRM DISARM Boot GTCR12hoot_1 0 User Password 6 symbols W Zone Auto Bypass PA Ted v1 20626 Temperature Scale Celcius APRDISARN khethacd Button Access ID On Touch Input Learn iButtone Stop Learning
13. ext Enable To send high temperature alarm Low Temperature Temperature value upon which heating device will be activated Heating device control hysteresis Heater Output To select output for cooling device control If heating device is not used select the option Disable Low Temp Alarm Temperature value upon reaching which low temperature alarm will be send High Temperature Alarm SMS Text Low temperature alarm SMS text is being recorded Enable To send low temperature alarm Temperature Sensor Calibration Temperature sensor value calculation coefficients They might be used to calibrate temperature measurements Temperature calculation formula T X ADC Y X multiplier Y coefficient Following the equation Temperature X ADC Y by selecting X and Y coefficients Temperature calibration may be performed in software SERA in testing window It is necessary to have accurate thermometer in order to measure temperature at least in two points In testing window to read temperature ADC indications in these points Following the equation Temperature X ADC Y to calculate X and Y coefficients Calculated X and Y coefficients should be programmed in the module It is easy to calculate X and Y coefficients in MC Excel by using trendline Software SERA for the GTC812 module www topkodas It 28 y 0 3284x 269 26 2 5 Q _ 5 2 Window Testing and Diagnostic window In order to open Testing and Diagnostic window
14. g 42 o ta Open Chrl c Close m Save Ctrl 5 Save S Read Device FS Exit Fig 43 Click the file of saved configuration or press Open in displayed Window Now all parameters of saved configuration have been loaded into application SERA If no any other changes are necessary press File gt Write Device Fig 43 in order to send this configuration into the module Software SERA for the GTC812 module www topkodas lt 32 8 Updating of firmware The latest software version may be found www topkodas It If a version of your module is older please update it to find out the version of your GTC812 software version FW firmware send Test SMS from your module For this purpose press Update in the menu list or Update module icon Fig 44 Specify the file of the newest software version and press Open Follow further instructions of the program SERA GTauto configuration File Edit Setup Devices Update Help sal ala ea i 31 Lje Update Module GT auto Configuration Select Firmware file of the module Open es Look irr gt FirnmvareUpdates e 1 Recent Places Mame Date modified T GTalarm_ 1 enc GTalarm v1_rl enc 2012 05 05 22 21 Wireshark captu 2011 04 13 18 53 Wireshark captu GTauto v3 enc 2011 02 19 12 21 Wireshark captu re aTauto_ w4 enc 2012 03 17 12 59 Wireshark captu Desktop GTC812 enc 2012 06 27 14 58 Wiresha
15. ible In Device Manager Window click symbol near Ports COM amp LPT in order to scroll Ports COM amp LPT menu If the module is powered with 12V and it is connected to the PC via USB port thus upon scrolling Ports COM amp LPT Window Fig 11 will be displayed o x File Action View Help l E H le 2 N 6 Eg HP H Acronis Devices E Batteries REJ Biometric Devices jEE Computer H a Disk drives nEn Display adapters DVDICD ROM drives Bribe ATAMATAPT controllers mt IEEE 1394 Bus host controllers A Imaging devices 5 Keyboards L Memory technology driver HJA Mice and other pointing devices fi Monitors 2 Network adapters Ports oe ee o USE serial Port ETN i i USB Serial Port COM i p Processors Hj System devices Hai Sound video and game controllers Universal Serial Bus controllers Fig 11 Software SERA for the GTC812 module www topkodas lt l1 From the displayed Window Fig 11 you must check what COM port is assigned to USB interface USB Serial Port COMS3 is displayed in the example This means that USB will be assigned to the third COM port Remember this COM port number and proceed with the clause Work with the software SERA 4 Connection of the module to your PC The module must be powered with 10 I5V gt 500mA voltage it should have inserted SIM card with replenished account and removed PIN CODE REQUEST connected GSM and the module must be connected to
16. ieaiao deem E eT an 14 5 2 Main Window of the software SERA System options ccccccccccssssssssesessssseeecceeeeeeeeeeeeeaeaaaas 15 Window GSM communication Options cccccccccccccsssessseccceceeeeaeeesseeeceeeeeeaaesseeeeeeeeeseaaaesseeeeeeeeeeaeeeens 18 Dio IREMIOle CONUOl DY SMO CAM jaja aE E E E eae 20 Die Widow OME S fesa a S 21 De WON IOUS I spa coscetecdie sete rence E R en seacagorsneaceoercsaiweestees wa eect E 23 30 Wmdow Event SMS TEKI reser ee ee ee 26 FJa Wndow TAi CA e E E S 26 Jl Wand Femme rates Conn oU E ess EEE EE 28 5 2 Window Testing and Diagnostic WIndOW cscssssseeeecceeeeeeeeeceaaaeaeeseeseseeeeeeeeeeeeeeeeeeeeaaaaaas 29 6 Saving module configuration into the file eeeeceeecccccceceeeseeeecceceeeeaeeeeseeeceeeeeseaeesseeeeeeeeeeaeeeeeses 31 7 Installing of saved configuration into the module cc eeeeeessecececeeeaeeeeeeceeeceesaaeeseeeeeeeeeeeaaaeesees 31 S Updating of HOWIE serene EEEE E EEE ESSN E EA ES 33 1 Installation of SERA software folder Software SERA for the GTC812 module www topkodas lt Open the folder containing installation of the software SERA Click the file SERA setup exe from the mentioned i SERA configuration program InstallShield Wizard Welcome to the InstallShield Wizard tor SERA configuration program The InstallShieldi Rt Wizard will install SERA configuration program on your computer To continue click Next WARNING Th
17. ing and Diagnostic Temperature Scale Celcius ARMOSARM Wethod Disable Learn iButtons Stop Learning f 4 30 Test Period f Daye O disabled Entry Delay 5 ao Tg Set Module Gock PC time 27 06 2012 14 39 52 Siren Time 120 3 Read Module Clock Module time Reset Module ee Tope _ GTcaiz COMB i closed gt Firmware file have been loaded Risso d aoe meee o an oe rol o See user manuals For details COME Disconnected ISTCB12v120626 E Fig 14 Set the COM port to initialize Go to Setup gt Serial Port Fig 15 File Edit Sate Devices Update Help 7 rot Fig 15 Window Serial Port Setup should be displayed Fig 16 Scroll the list and select COM port you saw in Device Manager window In the example the port USB Serial Config COM3 was assigned to the module Therefore select from the list COM3 and press OK AN Attention If you do not know the COM port you have connected the module please open Device Manager and read the chapter Selection of COM port Serial Port Setup Fig 16 Upon setting COM port information of the module should be read out Go to File gt Read Device or press Read Configuration icon Fig 17 Software SERA for the GTC812 module www topkodas It 13 SERA Glauto configuration File Edit Setup Devices Update Help sal ala ala SLs e GTauto Configuration Read Configuration Fig 17 R
18. ing this button stops testing of the module 30 6 Saving module configuration into the file After configuration of the module all settings may be saved at PC It enables to save time when next time the same configuration will be used it will not be necessary again to set the same parameters If you want to save that is already recorded by the module firstly you must read configuration of the module File gt Read Device see Fig 38 In order to save configuration go to File gt Save As Fig 39 or press icon Save icon Fig 40 Enter configuration parameter in the displayed table and press OK ta Open Chrl a Close m Save Ctrl 5 Save S il write Device Exit Fig 38 Fie Setup Devices Update Help ta Open Chrl a Close m Save Ctrl 5 Tl Read Device E Write Device Exit SERA GTauto configuration File Edit Setup Devices Update Help clara ea aal el GTauto Configuration Fig 40 7 Installing of saved configuration into the module In order to start saved configuration fat to File gt Open Fig 41 or press Open iconFig 42 File Setup Devices Update Help mj Save Ctrl 5 Save 45 Tl Read Device Write Device Exit Fig 41 Software SERA for the GTC812 module www topkodas lt 31 SERA Glauto configuration File Edit Setup Devices Update Help ofa aja ea alal e GTauto Configuration Fi
19. ion options T 0 user Phone shir DAL Nt sms N2 SMS NO SMS ima SMS NS SMS NE SWS ier SHS Test SHS ARW SMS DSARW SMS BAT I gt E E E E E E E E E User must type mobile number in T 1 14057272765 ra ra the international format Ne 2 ooo efo o lolol eo oe E 3 E O E E Ci E Ci E C C E Daa A r ea number witho ol E aiia m E E E E E E m m O m E g the mobile ac aes user in j 3 O E E O E E E a a E E United Kingdom is ENR 0 O0 O0 0l l OI O C C EE eva slope 0 the incorre and corre E EAP m m m m O m m m m m m entered numbers are E E E E E E O D O C E E Incorrectly entered user number E 9 E O E C C C C E E C T 44011 JXXXXHHX OF O11 3HEXHREH 4 7 z z z z z z z z z z z E user number 1 12 E E E E E E E E O E E 13 C O O E O O O C C E C 7 iz 14 4 T T C C C O O E T SMS Error Lirit ia H15 C T C C C C T T T T T Limit of dialing f 16 E O O E O E O E C O E 4 on Fig 21 Fig 22 File Settings Devices Update About lt a i fol 4 ial aa il a el x System Options GSM Communications Jo User F i USERS amp Remote Control USER Phone Number numbers must start with a the international format Aaa nt d it ist of th digits that a Outputs 140578545858 country code area it consi only those igi B Inputs code phone overseas callers must type Event SMS Text For example country code area code local T ii j 4477511111111 number without symbol E g the mobi
20. is program is protected by copyright law and international treaties Cancel Fig 1 In the displayed Window Fig 1 press Next gt ize SERA configuration program InstallSmeld Wizard Destination Folder Click Next to install to this Folder or click Change to install to a different Folder Install SERA configuration program to C Program Files topkodas SERA Fig 2 Installation directory will be displayed in the Window Fig 2 fig 2 If installation directory of the software is OK press Next If you want to install the software into other directory press Change Locate the another directory to install the software and press Next ize SERA configuration program InstallShield Wizard Ready to Install the Program The wizard is ready to begin installation TF you want to review or change any of your installation settings click Back Click Cancel to exit the wizard Current Settings Setup Type Destination Folder C Program Filestopkodas 5ER4 User Information Name D Company Install Cancel Fig 3 Check if the correct data are entered and press Install in the displayed Window Fig 3 Fig 3 Software SERA for the GTC812 module www topkodas It ie SERA configuration program InstallShield Wizard InstallShield Wizard Completed The InstallShield Wizard has successfully installed SERA configuration program Click Finish to exit the wizard Finish Cancel Fig 4 After
21. ish Equivalent of the text available in Text name which may be changed Words available in this field will comprise messages being sent Software SERA for the GTC812 module www topkodas It 26 Software SERA for the GTC812 module www topkodas It 21 5 1 Window Temperature Controller In order to open window of Temperature Controller Settings select Temperature Controller Temperature Controller Settings cooling Settings High Temperature 26 0 a High Temp Alarm SMS Alarm High Temperature Cooler OM Cooling Hysteresis jo aS High Temp ooler Hysteresi Disable Cooler Output a cadea EIFS High Temp Alarm 30 0 1E High Temperature Alarm Shis Text High Temp Alarm Enable i Heater OFF Heater Hystereesi as eating Settings Low Temp n _ Heater OM Low Temperature 40 0 ee ee ere l loz SMS Aan Low Temperature Heating Hysteresis ai Heater Output Disable Low Temp Alarm feo ae Low Temperature Alarm SMS Text Low Temp Alarm Enable Temperature Sensor Calibration 0 S466 w 274 5 y Equation Temperature 4 400 Fig 36 High Temperature Temperature value upon which cooling device will be activated To select output for cooling device control If cooling device is not used select the option Disable High Temp Alarm Temperature value upon reaching which high temperature MA eee High Temperature Alarm SMS Text Enter High temperature alarm SMS t
22. larm of the present input Restore If the check box is checked it means that the module will react towards restore of appropriate sensor after alarm response If the check box is not checked the module will not react towards restore of the present input Input Name Input type you may select after scrolling menu e NC normally closed contact e NO normally open contact e EOL normally closed contact with 1 resistor Input Def Input operation type you may select after scrolling menu e Delay Entry zone Set Entry delay and Exit Delay are applied for this zone Such type zones are used for connection of door sensor e Interior disturbance of this zone will not be responded if alarm of Delay type zone occurred and Entry Delay or Exit Delay time still have not expired Such type zones may be used for connection of motion sensor in front of the door The input will be activated immediately if the door has not been open before e Instant Instant zone Upon disturbance of this zone the system will immediately activate burglary alarm If the security system was ARM ed e 24hours Upon disturbance of this zone the system will activate burglary alarm not depending whether the security system is ARM or DISARM The applications of this type Software SERA for the GTC812 module www topkodas It 24 zones are safes storehouses tampers of the sensors e Silent silent zone is always active not de
23. layed System Properties Sistem Restore Automatic Updates Remote General Computer Mame Hardware Advanced Device Manager The Device Manager lists all the hardware devices installed on your computer Use the Device Manager to change the properties of any device Drivers Driver Signing lets you make sure that installed divers are compatible with Windows Windows Update lets you set up how Windows connects to Windows Update for drivers Hardware Profiles So Hardware profiles provide a way for you to set up and store el different hardware configurations Hardware Profiles Fig 9 Select Device Manager from the tab Hardware Window Fig 10 will be displayed Software SERA for the GTC812 module www topkodas It 10 Device Manager File Action View Help e 4 H 2 ce Computer cee Disk drives a Display adapters HLA DVD CD ROM drives Floppy disk controllers ig Human Interface Devices IDE ATA ATAPT controllers Keyboards i 1 Mice and other pointing devices 2 Monitors Network adapters i Ports COM amp LPT ae Processors SCSI and RAID controllers al Y System devices F Sound video and game controllers E eS Universal Serial Bus controllers Fig 10 AN Attention If the module GTC812 is not powered with 12V and it is not connected to the PC via USB interface menu Ports COM amp LPT item USB Serial Config COMx will not be vis
24. le number of user in United Kingdom is Please note that all phone sia User must type mobile number in e Temperature Controller Testing and Diagnostic Sending SMS Alarm Restore ialing to USER Alarm Restore 44 0 113 Xxx HEHH lv IN e I Select All 0 the incorrectly and correctly W IN2 i i Iw IN2 aa entered numbers are J INS fw INS Incorrectly entered user number F e Ind Clear All T INa Clear All 4404141 3xxxuxHE OF O44 3exKxEEKX Iv INS Iv INS Correcth entered user number IMB IMB 4411 3xxXXHEX M INT C n7 5 E T EMS Error Limit p Temperature emperature cd Limit of dialing P m v ARM ARM g M DISARM I DISARM PEE E A V Service Service eee eee Ee ne W TEST TEST Tee Period 0 min COME i amp closed i USB Device found COME Disconnected GTCB12v120626 2 Fig 23 Explanation of fields of GSM communication options Window DOD of the user to whom send SMS and make a call User Phone SMS and DIAL This column includes user numbers to whom GSM SMS messages will be sent and short calls will be made User 18 Software SERA for the GTC812 module www topkodas It phone number should be entered with international code Sending SMS Alarm Restore The events with check boxes will be send to selected users via SMS Dialling to USER Alarm Restore A user will be notified about these events the check bow should be checked by making him a short ca
25. ll SMS error limit SMS repetition limit in a case of failure to send SMS Limit of dialling It is a figure which specifies how many times to call to a user s telephone number in the event of alarm or if a user does not cancel call of the module If a user after 15 sec will reject a call the module will stop making calls till another event System Monitoring SMS This function is intended for permanent system monitoring The message contains information about in out states communication strength voltage and temperature Software SERA for the GTC812 module www topkodas It 19 5 3 Remote Control by short call To open Window Remote Control by Dialling it 1s necessary to select GSM Remote Control A window Fig 24 will be displayed including users table These users would be able to control the module by dialling The module will identify caller ID and if this ID will be available in the table the module will perform selected action It is possible to select few actions for one number however some of these actions may disturb each other In such case the microphone will not be able to turn on because when sending SMS message the module will automatically terminate the call The number of users up to 400 Remote Control Users table o username N _user Phone uton out outa oua oua Arnoa ODO O0 E OOOOO0000000 B cooooooooooo FF O O C E E ooooooooooo O O O C E 4 oooooooooooo C Hs oooacooocooon
26. oaded Fikes coe att ol eee oc zi wm bese E E See user manuals For details COMs Disconnected laTCE12v120626 O wi When updating of firmware will be finished the system will displayed the table below x ia gt Update successful Reset module to continue Then press RESET button Then press OK Read configuration of the module File gt Read Device Go to Main Window Check whether the firmware has been updated FW xxxxxxxxx ardvware details Ha GTC81 2w Boot GTC Zboot_1 v0 Puy GTC81 21 20626 Programme version 1s also visible below pO COM6 Disconnected GTC12v120626 j 2 Software SERA for the GTC812 module www topkodas It 34
27. pending on whether the security system is ARM or DISARM Upon disturbance of this zone SMS messages are being generated but the siren will not be activated These zones may be applied for voltage temperature control AC mains failure control and for alarm of silent panic e Fire this zone is always active not depending on whether the security system is in ARM or DISARM state The zone generates a special siren signal with interruptions The zone is applied for smoke sensors and for fire alarm Input speed It is the time in milliseconds which indicates the shortest signal for reaction of the module If signal is shorter the module will ignore it Repeat time The time period in seconds during this time repeatable zone events are ignored Changing of selected output state upon alarm ot restore Battery Fig 33 In8 Low Battery parameters e Alarm voltage voltage the module is connected to when this voltage is reached the 8 zone will be alarmed Restore voltage voltage the module is connected to when this voltage is reached the 8 zone will be restored Calibration coefficient if changed voltage indications might be calibrated Door Alarm Door Closed M m EOL delay 200ms 13 Disable PIRA Alarm PIR Restore r E EOL interior 200m 13 Disable PIR Alarm PIR Restore ri C EOL instant 200m 13 Disable Glass Break Glass Break al EOL instarit 200m8 1s Disable Fire Alarm Fire Restore ia EOL fire 200m 1s Disable P
28. ration of impulse when Pulse type is being selected in the column State Mode Invert Option to invert the output If the check box is to be checked the output will work as inverted State mode Output commutation type see Fig 27 e Pulse the output will work in pulse mode Pulse time seconds should be set in Out pulse time column Steady output will work on the steady level till the next commutation Software SERA for the GTC812 module www topkodas It 22 3 5 Window Inputs In order to open Inputs window it is necessary to select Input All input parameters are being described in this window Double click on the selected line in order to open input settings window see Fig 32 Alarm text Restore text Input Def Input speed Repeat time Input Name 1 Input 1 2 Input 2 3 Input 3 4 Input 4 5 Input 5 6 Input 6 T Input 7 5 Battery Input Name Door Alarm PIFA Alarm PRZ Alarm Glass Break Fire Alarm Panic Button Tamper Alarm Low Batery Alarm text Door Closed PIF Restore PIR Restore Glass Break Fire Restore Panic Button Tamper Restore Batery Restore Restore text delay interior instant instant tire silent 24 hours silent Input Def 200m 200M 200ms 200m 00me 2O0me 200m esims Input speed 1s 1s 1s 1s 1 1 BOO0s Repeat time Disable Disable Disable Disable Disable Disable Disable Disable Input 1 Input 2 Inpu
29. rk captu tc GTCOM_ 1 enc 2012 05 05 22 12 Wireshark captu a GTGPS enc 2012 05 05 12 03 Wireshark captu Libraries T Computer T Network Files of type Firmware files enc Cancel Press RESET button once and click OK in the displayed table x 0 Please connect and reset your hardware File name GTCS 2 enC r AA You will see the following progress bar at the bottom of the window coma Disconnected GTCOM v1 110516 E nnn FF Software SERA for the GTC812 module www topkodas lt 33 SERA Configuration Software GTC812 configuration File Settings Devices Update About goaten Options z GSM Communications e Temperature Controller i Testing and Diagnostic aos Porreres i GTcaiz f USERS amp Remote Control lo x aal el yetem Settings GSM Alarm System Access Control Temperature Controller ardvare details Installer Password 6 symbols E Auto reARM Hat GTCS 21 ae a ee o FA i oh ARMDISARM Boot GTC812bo0t_1vo Y a ee cee FA GTC812 1 20628 Temperature Scale Celcius Button Access ID On Touch Input Learn Buttons Stop Learning ARM DISARM Method yetem Timers Test Time Test Period Days O disabled Entry Delay _Set Module Cock PC time 0407 2012 23 12 12 Read Module Clock HModule ti me Reset Module Exit Delay Siren Time COMMS is closed Firmware file have been l
30. s calculating this time period after Delay type zone breaking If during that time the security system will not be disarmed The module will activate alarm state 1 e siren will be switch on and SMS will be send about alarmed zones Entry Delay It is insensibility time seconds of the module into Delay and Interior type inputs before the module enters to ARM mode This means that during timer count down of this time period the module will not activate alarm even if inputs will be activated Siren Time This time value specifies how long the Siren of security system will be active after occurrence of alarm Time period should be set in seconds from 1 sec to 999 sec Siren Peep on ARM DISARM When the function is active and the security system is turned into ARM state siren will beep once when turning into DISARM state it will beep twice been opened closed after DISARMing the system Zone Auto Bypass Upon checking the check box the system will allow to activate ARM mode even if certain zones have been triggered If the check box has not been checked the system will not allow to enter into ARM state in a case any of the the zones has been triggered Temperature It is temperature scale Two scale types are possible one of which may be selected after scrolling menu near the note Temperature e Celsius temperature indications according to Celsius scale e Fahrenheit temperature indications according to Fahrenheit
31. scale Hardware details This is info about the module e HW hardware version of the module e Boot start up program version BOOT This part of the software is able to update Firmware SW e FW Firmware version of the module Set Module Clock button Sets module s clock according to PC time Attention Upon failure of power supply voltage the module s clock Software SERA for the GTC812 module www topkodas It 16 shout be reset Read Module Clock button Set the module s RTC Real Time Clock Reset Module button This function operates as programmable function of the module RESET This function operates similarly as actual built in RESET module This function will not operate in the case of USB Serial Port is not open or FW program of the module is not functioning properly Software SERA for the GTC812 module www topkodas It 17 Window GSM communication options In order to open Window GSM SMS and DIAL communication options it is necessary to select GSM Communication clause Fig 19 The Window Fig 22 including user table whom GSM SMS messages are being sent and calls are being made User number up to 16 Double click on the selected line will show selected user window Fig 23to set what events should be sent to the specified number User numbers should be entered with international code Near the telephone number of each user check boxes which events will be sent to that user SM SMS and DIAL communicat
32. select Testing and Diagnostic option This Window is intended for testing of the module for operation analysis and diagnostics This feature is very convenient when installing the module Testing window Outi Onwott 359772032701 52r Out Oniott mucan READY E Signal level h 5 LTT TLL ares ene A An PEE Dutt OnvOTt SMS Service Centre Address r 069950115 14 A System State ARMDSARM System ARM ouch Inp System voltage i269 ki Sogra ADC Temperature fao CE O W High Temp Alarm Low Temp Alarm R Switch on testing Switch off testing Fig 37 Explanation of fields of Testing Window IN2 H This is indication of each input Checked check box nearby the INS appropriate input means that the said input zone was activated ING Number near each input is a coefficient indicating input voltage IN7 IN8 ARM DISARM Touch input Outputs states Out2 Checked box nearby the appropriate output means that this output Out3 is active Out4 Button Outl On Off By pressing buttons on off output states are controlled It is Software SERA for the GTC812 module www topkodas It 29 GSM info System voltage System State ARM DISARM command button Switch on testing mode button Switch on testing mode button Software SERA for the GTC812 module www topkodas It Button oe On Off convenient to use when it is necessary to test outputs operation Button Button Outs Ow Or On Off Button Out
33. t 3 Input 4 Input 5 Input 6 Input 7 Battery mo 4 Mm th E ty ba m Input Name Door Alarm PIFA Alarm PRZ Alarm Glass Break Fire Alarm Panic Button Tamper Alarm Low Batery Alarm text Door Closed PIF Restore PIR Restore Glass Break Fire Restore Panic Button Tamper Restore Batery Restore Restore text delay interior instant instant tire silent 24 hours silent Input Def 200m 200me 200ms 200m 200M 200M 200m BS000m s Input speed Repeat time Disable Disable Disable Disable Disable Disable Disable Disable Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Battery mo 4 Mm th E ty ba y Input Name Door Alarm PIRI Alarm PRZ Alarm Glass Break Fire Alarm Panic Button Tamper Alarm Low Batery Alarm text Door Closed PIF Restore PIR Restore Glass Break Fire Restore Panic Button Tamper Restore Batery Restore Restore text delay interior Y instant 24 houra silent fire interior stay instant stay Input Def 200m 200M z0 mE 200m 200M 200M 200m BS000m s Input speed Repeat time Disable Disable Disable Disable Disable Disable Disable Disable Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Battery mo 4 Mm th E ty ba y Software SERA for the GTC812 module Door Alarm PIRI Alarm PRZ Alarm Glass Break Fire Alarm Panic Button Tamper Alarm Low Batery Door Closed PIF Res
34. the PC via programming cable Run SERA exe USB Cable et tall GSM Antenna Bre zra DC 10 15V 0 5A Insert SIM Card ka id 5 Work with the software SERA Start the software SERA Go to Start gt All programs gt Topkodas gt SERA gt SERA or go to installation directory and click SERA exe SRA eee 0 x File Setup Devices Update Help Slal eal alal el COME is closed com Disconnected E Fig 12 If you are sure that the module is fully connected to PC and power supply please go to Devices gt GTC812 Fig 13 Software SERA for the GTC812 module www topkodaslt 2B Fig 13 File Settings Devices Update About ST auto w3 aT auto v4 GTSPS wi STS4L4RM v1 aT OM wi After you make a selection configuration window System Options will be opened Fig 14 SERA Configuration Software GTC12 configuration i z ioj x File Settings Devices Update About Sal ala sisi e yetem Settings p System Options H GSM Communications o an GSM Alarm Security System Access Control Temperature Controller Inputs ardyware details teats REELEE Event SMS Text Installer Password 6 symbols E ae reARM HA GTCS12w E Custom SMS Text PEPEE M Siren Peep on ARWMOISARM Boot GTC812boot_1vo Temperature Controller User Password 6 symbols IV Zone Auto Bypass PA GT 2v1 20626 i Test
35. tore PIR Restore Glass Break Fire Restore Panic Button Tamper Restore Batery Restore Alarm Restore Input Type M M EOL M C EOL M E EOL M E EOL M E EOL M E EOL Iw M EOL M M NC Fig 28 Alarm Restore Input Type al M a E Iw a i iii M E Iw O M Iw M M Fig 29 Alarm Restore Input Type M M EOL M C EOL M C EOL Iw E EOL M C EOL M E EOL a Iw EOL ra m NC Fig 30 Alarm Restore Input Type M m EOL M E EOL M E EOL Iw E EOL M E EOL Iw E EOL M Iw EOL ra ra Ne Fig 31 www topkodas It delay interior instant instant fire silent 24 hours silent 200m 200M 200ms 200m 200M 200M 200m BS000m s BOOS Disable Disable Disable Disable 23 INPUT 1 Settings x Zone Definition ho Zone Type Luggage opened Alarm SMS Text Luggage closed Restore SMS Text fone Options J Alarm Enabled fone Speed zooms ms J Restore Enabled Event Repeat Timeout E08 Fone Action Disable Explanation of fields of Inputs window mo o S Opmer S O Input Name It is the text which will be received by a user after alarm response of appropriate sensor This text may be changed It is the text which will be received by a user after restore of appropriate sensor This text may be changed Alarm If the box is checked it means that the module will react towards alarm response of appropriate sensor If the box is not checked the module will not react towards a
36. tule Fusbser_x86_x64 inF My Recent Documents Deskto p G My Documents PE h u p e bly Network File name fusbser_xB6_x64 ini Places Files of type Setup Information inf Cancel Ee Select driver file Windows XP usbser inf Windows 7 x86 or x64 usbser_x86_x64 inf Software SERA for the GTC812 module www topkodas It Found New Hardware Wizard Select the device driver you want to install for this hardware eg Select the manufacturer and model of your hardware device and then click Next IF you a have a disk that contains the driver you want to install click Have Disk M Show compatible hardware Model USB Serial Config i This driver is not digitally signed Have Disk Tell me why driver signing is important lt Back Cancel Press Next Hardware Installation p i AN The software you are installing for this hardware USE Seral Config has not passed Windows Logo testing to werty its compatibility with Windows esP Lell me why this testing i important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway Press Continue Anyway Software SERA for the GTC812 module www topkodas It
37. y Recommended Click Next to continue 4 Back Cancel Fig 6 Select Install from a list or specific location Advanced and press Next gt in the displayed Window Fig 6 Hardware Update Wizard Please choose your search and installation options Search for the best driver in these locations Use the check boses below to limit or expand the detault search which includes local paths and removable media The best driver found will be installed i Search removable media floppy CD ROM F Include this location in the search fiso arbat GT 4 Browse Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware Back Cancel Fig 7 In the displayed Window fig 7 select Don t search I will choose the driver to install Press Next gt Software SERA for the GTC812 module www topkodas It 5 Found New Hardware Wizard Select the device driver you want to install for this hardware Select the manufacturer and model of your hardware device and then click Next If you have a disk that contains the driver you want to install click Have Disk M Show compatible hardware USB Seral Contig ity This driver is not digitally signed Have Disk Tell me why driver signing iz inporkarnt Back Cancel Press Have Disk button Look in Re Disk F Fi Ee
Download Pdf Manuals
Related Search
Related Contents
新潟県指定居宅サービス等及び指定介護予防サービス等に関する基準要綱 Schlüter®-RENO-T - Schlüter Daets User Guide - Computing and Software 第8号 - 近畿産業考古学会 Teoria y Operacion de los frenos ABS2 AI Suite 3 Manual de usuario 8 Series Daytona 675 et Street Triple + R - E Blaupunkt TEV-501 User's Manual dreamGEAR Radium, PS3 [13] Chap.11 Trouble Shooting Copyright © All rights reserved.