1. HEALTHCARE TREATMENT CHAIRS User s Manual Index 1 Introduction 2 About this Product 3 Definitions 4 Safety 5 Environmental Specifications 6 Installation 7 Operation 8 Maintenance amp Cleaning 9 Warranty amp Service TF TC UserManual Rev No 0 Date 19 05 15 INTRODUCTION About this User Manual This User Manual contains instructions for the proper and safe use of Treatment Chairs which has to be strictly followed This User Manual has to be read and followed by every person using or handling these Treatment Chairs In case of any query kindly contact Janak Healthcare Pvt Ltd ABOUT THIS PRODUCT These Treatment chairs are non invasive medical devices used for utility of medical equipment by doctor medical paramedical hospital personnel to help and support them in diagnosis prevention monitoring treatment or alleviation of the disease The Treatment Chairs are manufactured and supplied in non sterile condition for use in normal hospital environment These Treatment Chairs are not directly used for any diagnostic measuring monitoring or therapeutic purposes or prevent nor alleviate diseases All type of wheel chairs are used to provide assistance and support to medical paramedical hospital personnel Treatment Chairs Features amp Technical Data 1033 1033A 1036 1038 1039 Please refer product catalogue TS D for salient features amp Technical Data of thes
2. Disposal Product and its defective parts especially elements made of plastic steel rubber curtain cloth material should be disposed off in accordance with the statutory rules and regulations prevailing for such disposal The user is advised to contact Janak Healthcare Pvt Ltd for further assistance TF TC UserManual Rev No 0 Date 19 05 15 Routine Inspection Check List Inspection By The User Recommended Frequency Every new allotment but not later than three month Checks Observation OK Not OK Description of faults Visual check of the mechanical components Screws and rivets are tightened Missing loose PU Foam Mattress Rexine Tear Puncture soiled torn Product Specific Performance check of all mechanical components Castors Product specific Locking release Remove Result of inspection cotton thread hairs etc from axle Sign Result of inspection Date Trouble Shooting Guide PROBLEM POSSIBLE CAUSES REMEDY Castors Product specific No Braking No Movement Broken Repair Replace Castors TF TC UserManual Rev No 0 Date 19 05 15 10 WARRANTY amp SERVICE Janak Healthcare Pvt Ltd warrants solely to the end users of this product that for a period specified in the warranty certificate such product shall perform as per its intended use The foregoing warranties shall not apply if the Product has been subjected to a physical abuse misuse abnormal
3. H on the S S tubular frame as shown above with the help of nut and bolt and tighten them 2 Fixthe safety belt as shown above With due consideration to environmental limitations materials used to make the device are not affected A by contact with any bio chemicals or bio waste When used as per its intended purpose all materials used in the product and accessories do not facilitate any breeding or growth of bio contaminants on their own Load bearing capacities Product Safe working load kgs 1033 135 1033A 135 1036 135 1039 100 TF TC UserManual Rev No 0 Date 19 05 15 A Do not exceed the safe working load mentioned above MAINTENANCE amp CLEANING Maintenance Each time before putting the Treatment Chairs into service the user must check for e Lubrication of all the mechanical joints pins moving parts tightening of the bolts are done properly to avoid unnecessary play sound and wear amp tear of the Treatment Chairs e Visualinspection for any mechanical damage e g loose missing rivets screws etc any damage or malfunction is observed immediately report this matter to the operator the Treatment Chairs is not in use it should be stored in a dry and rodent free indoor environment on flat surface with gradient not more than 5 degrees the Treatment Chairs is not in use for long term it is necessary to conduct a test to check for fun
4. use or use not consistent with Janak Healthcare Pvt Ltd s published directions 6 any modification by anyone other than Janak Healthcare Pvt Ltd or third parties designated by Janak Healthcare Pvt Ltd or c fraud tampering negligence or accidents depending upon the nature of the products Limitation Of Liability In no event shall Janak Healthcare Pvt Ltd be liable or obligated to the end user in any manner for any special non compensatory consequential indirect incidental statutory or punitive damages of any kind including without limitation for injury or loss of life lost profits lost sales lost revenue loss of any software or data or loss of use of any hardware software or data regardless of the form of action whether in contract tort negligence strict product liability or otherwise even if Janak Healthcare Pvt Ltd has been informed of or is aware of the possibility of any such damages in advance Janak Healthcare Pvt Ltd s total aggregate liability under this agreement and in relation to anything which Janak Healthcare Pvt Ltd has done or not done in connection with this agreement shall be limited to the price of the products purchased and paid for by the end user during the period in which such liability arises The limitations set forth above shall be deemed to apply to the maximum extent permitted by applicable law and notwithstanding the failure of the essential purpose of any limited remedies In o
5. ctioning and any mechanical damage that may have been caused e Depending on the usage certain moving parts may require replacement due to wear amp tear We recommend imely replacement with original spares for safety and trouble free operation Any kind of fire source should be prohibited near the mattress cloth material to avoid any fire hazard as these materials do not have flame retardant properties TF TC UserManual Rev No 0 Date 19 05 15 Cleaning amp Disinfecting e The Treatment Chairs are not suitable for machine wash or steam cleaning e Donotuse water jet for cleaning e The Treatment Chairs cannot tolerate the influence of strong solvent basic or alkaline liquids amp caustic agents The cleaning agents must not contain any substances which bring about any change in the structure or dhesive property of the plastic Treatment Chairs should be properly cleaned and disinfected at regular intervals to avoid infection and stains Immobilize the Treatment Chairs amp remove all the detachable accessories and components before cleaning e We recommend use of approved disinfectant and cleaning agents to clean the Treatment Chairs Take extra care to clean areas that may trap dust or dirt All detachable accessories and its component can be cleaned separately Do not expose the Treatment Chairs to excessive moisture as corrosion may cause personal injury or equipment damage
6. e products Treatment Chairs Variants 1033 1033A 1036 TF TC UserManual Rev No 0 Date 19 05 15 1038 DEFINITIONS Operator Operator is the person appointed by the owner i e clinic hospital management etc who will be responsible for the safe operation of these Treatment Chairs User User is a person who is capable of assessing clinical condition of patient e g specialist medical personnel doctors nursing staff attendants etc On the basis of their training experience or through the instructions they are entitled to use these Treatment Chairs on their own responsibility or to carry out work on it and are able to recognize and control possible risks to the patient as well as the Treatment Chairs Patient The patient is a person who is ill infirm disabled or in need of medical assistance SAFETY In this User Manual the following safety symbols are used 2 TF TC UserManual Rev No 0 Date 19 05 15 Danger This symbol will appear wherever safety instructions are designed to protect people from physical harm The symbol stands for imminent danger of death or serious injury Caution This symbol will appear where situations are described which might be dangerous and which might inflict slight injuries gt gt Advice This symbol will appear in front of additional helpful pieces of advice Adotin front of the text implies the action that is required t
7. el Chair MS Tubular frame with Castors Footrest Cushion Seat Product Specific Safety Belt 1036 S S Rigid Wheel Chair Wheel Chair S S Tubular frame with Castors Footrest Cushion Seat Safety Belt No No No No No No No No No No No Nos Nos Nos Rest of the product 1039 Foldable Chair are factory fitted and come in ready to use Notify if any damage has occurred during transportation either to the authorized agent or directly to Janak Health Care Pvt Ltd Installation of the Treatment Chairs should be done only by Janak trained technicians wherever required 1038 TF TC UserManual Rev No 0 Date 19 05 15 1 Place the L H frame on the floor and fix the R H frame as shown above with the help of frame support tube and ABS top supporter Keep the frame on upward position and fix the backrest frame into the space provided as shown above Fix the armrest L H and R H on the side frame and backrest section and tighten it with the help of wing nuts as shown above 4 Place the ABS top on the supporter tube as shown above 1033 1033A a S 1 Fix the footrest L H and R H on the M S tubular frame as shown above with the help of nut and bolt and tighten them 2 safety belt as shown above TF TC UserManual Rev No 0 Date 19 05 15 1036 1 Fix the footrest L H and R
8. o be taken Safety Instructions e Ensure that the Treatment Chairs is assembled and installed in accordance with the instructions given in this User Manual wherever required Restrict child visitors without proper attendants Supervision is necessary to avoid any mishap due to unintended movement of the Treatment Chairs e Ensure that the Treatment Chairs is moved a smooth stepless floor without any obstructions in its path to prevent any inconvenience to User and damage to the Treatment Chairs Keep some gap between walls and Treatment Chairs while in stationary position and also while moving from one place to another e Keep the User Manual handy with the Operator User for ready reference ENVIRONMENTAL SPECIFICATIONS Usage Storage and Transport Temperature 10 C to 50 C Relative Humidity 0 to 95 non condensing Atmospheric Pressure 800 1060 hPa Altitude lt 2000 INSTALLATION AND OPERATION 1 Unpackallthe components carefully 2 Ifthe packing is drenched by rain water or other liquids inform this matter to the operator 3 Each Productis supplied with the following components as per packing list 1038 Commode Chair Side frame L H with Castors 1No Side frame R H with Castors 1No Frame Support Tube 2Nos TF TC UserManual Rev No 0 Date 19 05 15 Backrest frame ABS Top Supporter Wing Nut ABS Top Armrest R H S S Armrest L H S S 1033 1033A Wheelchair Whe
9. rder to maintain functional safety and right to claim under the warranty only original replacements parts may be used For ordering replacement parts customer service request and further question please contact our technical support department Disclaimer Every effort has been made to ensure that the information in this user manual is valid Janak Healthcare Pvt Ltd reserves the right to change the information in this document without prior notice MANUFACTURER S ADDRESS Corporate Office Janak Healthcare Pvt Ltd Unit No 12 1st Floor Kalpataru Point Opp Cinemax Theatre Sion Circle Sion E Mumbai 400022 Tel 91 22 4915 3000 Fax 91 22 4915 3100 www janakhealthcare com Registered Office Janak Healthcare Pvt Ltd Janak House Opp Indian Oil Corp Depot Sheikh Misry Road Wadala E Mumbai 400 037 India 91 22 2413 0407 2418 0637 Fax 91 22 2413 9870 Toll Free No 1800 22 8020 Email technicalsupport janakhealthcare com TF TC UserManual Rev No 0 Date 19 05 15 EALTHCARE JANAK HEALTHCARE PVT LTD Unit No 12 1st Floor Kalpataru Point Opp Cinemax Theatre Sion Circle Sion E Mumbai 400 022 Tel 91 22 4915 3000 Fax 91 22 4915 3100 www janakhealthcare com