Home

Operating Instructions

image

Contents

1. FEIG ELECTRONIC GmbH VEK MNE2 R24 C VEK MNE2 R230 C Operating Instructions Double Channel Inductive Loop Detector 2 2 1 LED Channel 1 DIP Switch 1 8 LED Channel 2 DIP Switch 9 12 Diagnostic USB Reset Button Characteristic features 11 pole circular connector galvanic separation of loop and detector electronics automatic system adjustment directly after power on sensitivity adjustment independent of loop inductivity Loop busy signal emitted by LED display potential free relay contacts at the outputs loop fault message via LED signal indication of historical loop fault continuous rebalancing of frequency drifts in order to avoid environmental influences diagnostics by external Service Program via USB Mini connector Settings Use the following DIP Switches for the standard settings DIP 1 DIP 3 Sensitivity DIP 2 DIP4 Function OFF ON More detailed Sensitivity settings via USB Interface OFF OFF Low Medium Low OFF ON Medium High ON ON High 2 2 Frequency DIP 5 Function OFF Low 2 3 ON High Hold Time DIP 6 OFF Function 5 Minutes More detailed Hold Time settings via USB ON Infinite Interface Output Mode Relay 2 DIP 7 Function OFF Presence Output on Relay 2 Setting dgesn t alfect ON Pulse Output on Relay 2 RR Output Edge Relay 2 DIP 8 Functi
2. 5 Diagnostics To display more details of the induction loop system e g frequency detuning busy time output signals use the Service Program 6 Pin Assignment Function Power AC Line DC pos Power AC Neutral DC neg Relay 2 N C Relay 2 Com Relay 1 N C Relay 1 Com Loop 1 Loop 1 Loop 2 Loop 2 2 5 O OO N OD oO A vN lo lo 7 Technical Data Dimensions 76 x 38 x 71 mm Hx W xL Power Supply R24 10 30 V AC DC max 1 W R230 90 250 V AC 50 60 Hz max 2 W Operating Temp 37 C 70 C Relays max 2 A 230 VAC 60 W 125 VA Loop Inductivity 20 700 WH recommended 100 300 uH Frequency 30 130 kHz 2 steps Supply Line max 200 m Resistance max 20 Ohm incl Loop Supply Line Connectors Power Loop 11 pole circular connector Diagnostic USB Mini AB FEIG ELECTRONIC GmbH Lange Strasse 4 D 35781 Weilburg Tel 49 6471 3109 0 Email info feig de www feig de VEK MNE2 C_DE_EN_2014 09 17 docx as 17 09 2014 FEIG ELECTRONIC GmbH
3. VEK MNE2 R24 C VEK MNE2 R230 C Bedienungsanleitung 2 Kanal Verkehrsdetektor LED Kanal 1 DIP Schalter 1 8 LED Kanal 2 DIP Schalter 9 12 Diagnose USB Reset 1 Charakteristische Eigenschaften 11 poliger Rundstecker Galvanische Trennung zwischen Schleife und Detektorelektronik Automatischer Abgleich des Systems nach dem Einschalten Empfindlichkeitseinstellung unabh ngig von der Schleifeninduktivit t Belegtmeldung durch LED Anzeige Potentialfreie Relaisausg nge Meldung Schleifenfehler durch LED Anzeige Signalisierung historischer Schleifenfehler Kontinuierlicher Nachgleich von Frequenzdriften zur Ausschaltung von Umwelteinfl ssen Diagnose mit externem Service Programm ber USB Mini 2 Einstellungen Die nachfolgenden Standardeinstellungen k nnen wie ber die DIP Schalter vorgenommen werden 2 1 Empfindlichkeit Sense a b DIP 1 DIP 2 Dip 3 Dip4 Funktion Weitere Einstellungen OFF OFF niedrig der Empfindlichkeit ON OFF mittel niedrig ber USB OFF ON mittel hoch Schnittstelle ON ON hoch 2 2 Frequenz Frequency DIP 5 Funktion OFF Niedrig ON hoch 2 3 Haltezeit Hold Time DIP 6 Funktion Weitere Haltezeiten OFF 5 Minuten ber USB Schnittstelle ON unendlich einstellbar 2 4 Ausgabe Relais 2 Output 2 DIP 7 Funktion f Einstellung betrifft nur OFF Dauersignal an Relais 2 Relais 2 ON I
4. berschrieben oder Signalisierung behobener historischer Schleifenfehler Blinken Blinken Ausgabe der Frequenz in kHz Eine oder mehrere Einstellungen der per DIP Schalter gew hlten Funktionen wurden durch das Service Programm berschrieben Beispiel f r Schleifenfrequenz 57 kHz Zehnerstelle Einerstelle 5x 10 kHz 7x 1 kHz gt 57 kHz 5 Diagnose Weitere Details des Verkehrsdetektors z B aktuelle Frequenz aktuelle Verstimmung Belegtdauer Zustand der Relaiskontakte usw k nnen mit dem Service Programm am PC dargestellt werden 6 Belegung 11 poliger Rundstecker Kontakt Funktion 1 Versorgung L 10 30 V 2 Versorgung N GND 3 Relais 2 Offner 4 Relais 2 COM 5 Relais 1 Offner 6 Relais 1 COM 7 Schleife 1 8 Schleife 1 9 10 Schleife 2 11 Schleife 2 7 Technische Daten Ma e 76 x 38 x 71 mm HxBx L Versorgung R24 10 30 V AC DC max 1 W R230 90 250 V AC 50 60 Hz max 2 W Betriebstemperatur 37 0 70 C Relaiskontakte max 2 A 230 VAC 60 W 125 VA Schleife Induktivit t 20 700 uH empfohlen 100 300 uH Frequenz 30 130 kHz 2 Stufen Zuleitung max 200 m Widerstand max 20 Ohm inkl Schleifenzuleitung Stecker Versorgung Schleife Relais 11 poliger Rundstecker Diagnose USB Mini AB FEIG ELECTRONIC GmbH Lange Strasse 4 D 35781 Weilburg Tel 49 6471 3109 0 Email info feig de www feig de VEK MNE2 C_DE_EN_2014 09 17 docx as 17 09 2014
5. mpulssignal an Relais 2 2 5 Zeitpunkt Impulsausgabe Edge 2 DIP 8 Funktion Einstellung betrifft nur OFF Impuls beim Befahren Relais 2 in Funktion ON Impuls beim Verlassen Impulssignal 2 6 Richtungserkennung Dir Mode DIP 9 Funktion OFF Anwesenheitserkennung ON Richtungserkennung 2 7 Richtungslogik Dir Logic DIP 10 Funktion Nur bei aktivierter OFF Richtungslogik Dauersignal Richtungserkennung ON Richtungslogik Impulssignal wirksam 2 8 Relaisprinzip Inv Out 1 2 DIP 11 DIP 12 Funktion OFF Arbeitsstromprinzip ON Ruhestromprinzip DIP Schalter 11 ndert Relais 1 und DIP Schalter 12 Relais 2 Weitere Einstellm glichkeiten Anzugsverz gerung Abfallverz gerung Verhalten bei Schleifenfehler usw und detaillierte Einstellungen Empfindlichkeit Haltezeit Ausgabefunktionen usw sind ber USB Schnittstelle mit dem Service Programm m glich 3 Reset Taste Zum R cksetzen der Signalisierung von historischen Schleifenfehlern und zum Neuabgleich des Verkehrsdetektors die Reset Taste 1 s dr cken bis die rote LED blinkt 4 LED Ausgabe Rot Blau Funktion OFF OFF Versorgungsspannung fehlt OFF Schnelles Neuabgleich der Schleifen Blinken OFF ON Betriebsbereit Schleife frei ON ON Betriebsbereit Schleife belegt ON OFF Schleifenfehler x Blinken DIP Schalter Einstellung durch USB Schnittstelle
6. on Available only if OFF Pulse on Loop Entry Relay 2 is in Pulse ON Pulse on Loop Exit Output Mode 2 6 Direction Mode DIP 9 Function OFF Presence Output 2 7 ON Direction sensitive Output Direction Logic DIP 10 Function Available only if OFF Dir Logic Presence Output Direction Sensitive ON Dir Logic Pulse Output Output is active 2 8 Fail Save Fail Secure DIP 11 DIP Switch 11 inverts DIP 12 Function output signal on OFF Non Inverted Output Signal Relay 1 and DIP ON Inverted Output Signal Switch 12 on Relay 2 More settings Delay Extension Loop Fail Output or more detailed settings Sensitivity Hold Time Output Modes can be done via USB Interface with the Service Program 3 Reset Button Press Reset Button 1 s until red LED is flashing to reset retune detector and clear historical Loop Fault 4 LED Red Blue Function OFF OFF Nosupplyvoltage OFF Fast Calibration Retuning Loops Flashin OFF ON Ready for operation Loop free ON ON Ready for operation Loop active ON OFF Loop Fault x Flashing Historical Loop Fault or DIP Switch setting overwritten by USB Blinking Blinking Output Loop Frequency in kHz If one or more DIP Switch setting is overwritten by the service program via USB interface Example for loop frequency 57 kHz Tens Units 1s 5x 10 kHz 7x 1 kHz gt 57 kHz

Download Pdf Manuals

image

Related Search

Related Contents

IPL, Verts Loisirs, VL12T92, VL12T92A, 2003  modd. STAR 505R e STAR 505M  PP B6 EQ-BID.indd  User Manual - Global Telesat Communications  VPLSW125  MSDS - ミヤキ  Manual de Instalación  Braun MQ 940cc  Measuring equipment for the Sunny Central  reusable high temperature cautery with replaceable tip high  