Home

SIMADYN D Digital Control System Board MM4

image

Contents

1. 1EB 20 14mm approx 500g 800mA 60V DC 1A 0 5A 20W 6 STRUC L mask in the master program MM4 Buffer memory module L C bus 2Mbyte 4 Edition 05 95 Siemens AG Dk Nr 251441 SIMADYN D Hardware User Manual Attachments 7 Attachments 7 1 Block diagram Edition 05 95 Siemens AG Dk Nr 251441 SIMADYN D Hardware User Manual Attachments 7 2 Layout diagram Layout diagram 3SE 465 611 9006 00 AO 7 3 Dimension drawing Dimension drawing 2SE 465 611 9006 00 MB 6 Edition 05 95 Siemens AG Dk Nr 251441 SIMADYN D Hardware User Manual ECB instructions 8 ECB instructions Components which can be destroyed by electrostatic discharge ECB Generally electronic boards should only be touched when absolutely necessary The human body must be electrically discharged before touching an electronic board This can be simply done by touching a conductive grounded object directly beforehand e g bare metal cubicle components socket outlet protective conductor contact Boards must not come into contact with highly insulating materials e g plastic foils insulated desktops articles of clothing manufactured from man made fibers Boards must only be placed on conductive surfaces When soldering the soldering iron tip must be grounded Boards and components should only be stored and transported in conductive packaging e g metalized plastic
2. PERSONNEL For the purpose of this User Manual and product labels a Qualified person is someone who is familiar with the installation mounting start up and operation of the equipment and the hazards involved He or she must have the following qualifications 1 Trained and authorized to energize de energize clear ground and tag circuits and equipment in accordance with established safety procedures 2 Trained in the proper care and use of protective equipment in accordance with established safety procedures 3 Trained in rendering first aid DANGER For the purpose of this User Manual and product labels Danger indicates death severe personal injury and or substantial property damage will result if proper precautions are not taken WARNING For the purpose of this User Manual and product labels Warning indicates death severe personal injury or property damage can result if proper precautions are not taken CAUTION For the purpose of this User Manual and product labels Caution indicates that minor personal injury or material damage can result if proper precautions are not taken NOTE For the purpose of this User Manual Note indicates information about the product or the respective part of the User Manual which is essential to highlight CAUTION This board contains components which can be destroyed by electrostati discharge Prior to touching any electronics board your body must be electrically
3. SIMADYN D User Manual Digital Control System Board MM4 Edition 05 95 DK Nr 251441 User Manual Board MM4 AE Board MM4 an D e Copying of this document and giving it to others and the use or communication of the contents thereof is forbidden without express authority Offenders are liable to the payment of damages All rights are reserved in the event of the grant of a patent or the registration of a utility model or design We have checked the contents of this Manual to ensure that they coincide with the described hardware and software However deviations cannot be completely ruled out so we cannot guarantee complete conformance However the information in this document is regularly checked and the necessary corrections included in subsequent editions We are thankful for any recommendations or suggestions Contents Contents Warning iNOMATON Essen es Halli 1 1 Ordeting information4 2 2 nein de e tint da E 3 FUNCION era Re A tte se PA MR RE tte A dedos A 3 BO tel de 3 4 Application into Mati ita adopta 4 NEC e e e e fds 4 6 STRUC L mask in the master program su 4 O 5 TT A Lan AA rer ee da entre 5 Tien Eayout diagrama 2 O Heat 6 7 38 Dimension drawing 2 ee ren lata 6 SL EGB INSIMCUIONS ir a tate RS A o et 7 Siemens AG Dk Nr 251441 Edition 05 95 SIMADYN D Hardware User Manual Warning information Edition 05 95 Siemens AG Dk Nr 251441 SIMADYN D Hardware User Manual Warning information NO
4. TE The information in this Manual does not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes please contact your local Siemens office Further the contents of this Manual shall not become a part of or modify any prior or existing agreement committment or relationship The sales contract contains the entire obligation of Siemens The warranty contained in the contract between the parties is the sole warranty of Siemens Any statements contained herein do not create new warranties nor modify the existing warranty Warning information WARNING Electrical equipment has components which are at dangerous voltage levels If these instructions are not strictly adhered to severe bodily injury and material damage can result Only appropriately qualified personnel may work on this equipment or in its vicinity This personnel must be completely knowledgeable about all the warnings and service measures according to this User Manual The successful and safe operation of this equipment is dependent on prope handling installation operation and maintenance Siemens AG Dk Nr 251441 Edition 05 95 1 SIMADYN D Hardware User Manual Warning information Definitions QUALIFIED
5. boxes metal containers If the packing material is not conductive the boards must be wrapped with a conductive packing material e g conductive foam rubber or household aluminum foil The necessary ECB protective measures are clearly shown in the following diagram a Conductive floor surface d ECB overall b ECB table e ECB chain c ECB shoes f Cubicle ground connection Siemens AG Dk Nr 251441 Edition 05 95 7 SIMADYN D Hardware User Manual ECB instructions 8 Edition 05 95 Siemens AG Dk Nr 251441 SIMADYN D Hardware User Manual ECB instructions Drives and Standard Products Motors and Drives Systems Group Postfach 3269 D 91050 Erlangen System Based Technology Siemens AG Dk Nr 251441 Edition 05 95 9 SIMADYN D Hardware User Manual
6. discharged This can be simply done by touching a conductive grounded object immediately beforehand e g bare metal cabinet components socket protective conductor contact WARNING Hazardous voltages are present in this electrical equipment during operation Non observance of the safety instructions can result in severe personal injury or property damage It is especially important that the warning information in all of the relevant Operating Instructions are strictly observed 2 Edition 05 95 Siemens AG Dk Nr 251441 SIMADYN D Hardware User Manual Ordering information 1 Ordering information MM4 6DD 1611 OAGO 2 Function description Board MMA is used in the SIMADYN D system as general RAM memory board on the local and communications bus for 32 bit processor boards The 32 bit processors PMxx PTxx can communicate with one another via the MM4 board whereby the MM4 is inserted directly to the right of the master processor Processor Buffer Processor Processor module 1 memory module 2 module 8 Bus system Data transfer between the individual processor modules is realized as follows Each processor module addresses the bus and after successful bus access data is written into the buffer memory The particular partner must then also access the bus and retrieve the data from the buffer memory The operating system automatically handles the buffer memory address administration Acce
7. ss can either be bitwise or wordwise 2 Mbyte is available for each bus A relay is located on the board which outputs the RDYIN bus signal This sigral is extended to a minimum time of 150 ms 300 ms can be set If RDYIN is active for longer than the minimum time then it is output for the time for which it is effective The relay contact drops out under fault conditions 3 Board design E Connection for the local X2 and communications bus X1 E 2 megabyte RAM for each bus 120 ns RAM access time E 8 or 16 bit data Board identification with PAD equivalent circuit E Board code 31H E Relay contact to output the RDYIN signal X3 Siemens AG Dk Nr 251441 Edition 05 95 3 SIMADYN D Hardware User Manual 4 Application information To ensure perfect operation also during start up the board must be screwed tightly into the subrack 5 Technical data INSULATION GROUP AMBIENT TEMPERATURE STORAGE TEMPERATURE HUMIDITY RATING acc to DIN 40040 ALTITUDE RATING acc to DIN 40040 acc to VDE 0110 degree of pollution 2 insulating material class Illa 0 to 55 C 40 to 70 C F S DEGREE OF PROTECTION acc to DIN 400501P00 MECHANICAL STRESSING PACKAGING SYSTEM DIMENSIONS BOARD WIDTH WEIGHT CURRENT DRAIN P5 Typical value DATA OF THE RDYN OUTPUT AT X3 Max voltage Continuous current Max switching current Switching power acc to SN 29010 Class 12 ES 902 C 233 4mm 220mm 1 1 3 SPS

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`utilisateur L410 (document pdf)  User Manual - SVT Innovations  Operating Instructions RaceCar Tymp  none 82392055936 Instructions / Assembly  gCast: Email Creator User Manual  CATEYE STEALTH 50  User Manual - horeca apparatuur Gastrohome de Jong  Digital 5 Kg - IFB Industries  HEART RATE MONITOR  