Home
IP•54 - Petri Konferenztechnik
Contents
1. diagrams te eine 17 Components and PANES 22 Technical 23 Appendix DMX page 26 Appendix 27 4 02 05 A PATENT SYSTEM SYSTEM INTERNATIONAL PATENT WO99 40361 l Petri Konferenztechnik GmbH Zentrale Crailsheimer Str 1 90574 Roftal Buchschwabach Zweigstelle Lerchenbuhlstr 17 90419 N rnberg Telefon 49 0 91 27 90 33 80 Telefon 49 0 80 13 220 2 Telefax 409 9127 90 33 89 Telefax 49 0 80 13 221 2 e Mail info petri konferenztechnik de www petri konterenztechnik de etri konferenztechnik de petri konfi technik d Full Service Konferenz Messe und Veranstaltungstechnik WARNING READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT INSTRUCTION TO PREVENT INJ URY OR DAMAGE DUE TO ELECTRIC SHOCK FIRE MECHANICAL HAZARDS AND UV RADIATION HAZARDS SAFETY INFORMATION e PROTECTION AGAINTS FIRE 1 IMPORTANT Use only the lamps showed on page n 3 DO NOT USE ANY OTHER TYPE LAMP 2 Maintain minimum distance of 0 5 meter from walls or any other type flammable surfaces 3 Maintain minimum distance to lighted objects of 5 0 meter 4 Replace fuses only with the specified type a
2. Projector User s manual e Power connector eStudio Due warranty Available on request eart 9801 a barndoor to define illuminated surface eart 0003 anti glare eart 0002 a XLR pin male IP54 connectors eart 0002 b XLR 3 pin female IP54 connectors e Lamp TECHNICAL FEATURES LAMPS MHN SA 1800W PHILIPS art 9801 0002 HTI DE 2500W OSRAM MSA DE 2500W PHILIPS art 0003 Color temperature 5 600 K Color temperature 6 000 K Lamp life 2 500 hours Lamp life 2 000 hours Luminous flux 180 000 Im Luminous flux 260 000 Im COLOR SYSTEM Full CYM color mixing unlimited variety of colours and shades High resolution stepper motors Shutter dimmer The color changer can be drived with 4 different speeds or in real time ANGLE 50 intensity 50 x52 e CONTROL INPUT Standard interface RS 485 opto couplet input Protocol USITT DMX 512 e SETUP AND CONFIGURATION On the control panel with menu and buttons e AUTOMODE Stand alone control auto mode function master slave synchro mode with 27 programs RATE 54 art 0002 0003 e POWER SUPPLY art 0002 magnetic ballast Rated voltage 230V 50Hz request 200V 50Hz 208V 60Hz 230 60 2 240V 50Hz Rated current 10A Rated power 2000W e POWER SUPPLY art 0003 magnetic ballast Rated voltage 230V 50Hz sam 1 a request 200V 50Hz 208V 60Hz 230V 60Hz 240V 50Hz iex19 2 m Rated
3. display stops flashing it flashes to indicate that the selected option is different from the pre set The available options no normal for the functioning in DMX reception 01 27 pre set 01 27 for the master functioning with the respective game SL slave for the functioning as slave To go back to the options without any change press the MENU button Mode no use of the CityColor in DMX 512 1 27 master functioning with execution of the 27 stored programme SL use of the CityColor in SLAVE MODE EXAMPLE OF CONNECTION AND SETTING OF 4 CITYCOLOR IN SYNCHRO MODE MASTER WARNING The cables are the same as the DMX standard cable EXAMPLE OF CONNECTION AND SETTING OF 4 CITYCOLOR IN INDIPENDENT AUTO MODE MASTER MASTER MASTER MASTER TROUBLESHOOTING GUIDE Before calling for technical assistance follow the recommended procedures in this appendix to solve many problems on your fix ture CAUTION BEFORE YOU BEGIN Before you perform any troubleshooting procedures read the following personnel and equipment safety precautions 1 Refer servicing to service personnel Q T qualified technician no user serviceable parts inside 2 Wear hand and eye protection 3 Wait at least five minutes before accessing the lamp after operation 4 Disconnect the unit from power before removing any cover Q T If the procedures do not solve your problem and you need to call for assistance please prov
4. if they are visibly damaged and their effectiveness has been reduced for example by cracks or deep scratches 5 The lamp must be replaced if it has been damaged or thermally deformed 6 Clean regularly the in out ventilating grilles 7 Do not handle the spot by taking it by the head but always by using the special handles pict 2 In case of replacement of the lamp or maintenance do not open the fixture unless 5 minutes have passed from the switching off WARNING This operation has to be done when the apparatus is disconnected from the mains supply INSTALLATION OF THE DISCHARGE LAMP art 0002 0003 see pic 2 OOS oH 9 Disconnect power before lamp s replacement Wear gloves and goggles Remove completely the pommels A on the base of the head Open the base of the lamp room G Remove the two lateral reflectors C Lift up the two lampholder D Install the new lamp Taking care that protuberance of the bulb is set towards the reflector Do not touch the quarz bulb with fingers If this happenes clean the bulb before use with dry cloth and alcohol Put down the two upper lampholders D Connect the cables E to the two ends of the lamp or connect the two cables of the lamp to the two red insulators on the rear panel of the head Put in again the two lateral plane reflectors 10 Close the rear panel and install again the two pommels A and hold them tightly IP RATE The declared IP ra
5. on check PCB PAN IP 2 Check U13 78 05 D6 If the led 5V is off 1 Disconnect TO DISPLAY PCB PAN IP connector if the led is on check PCB PAN IP 2 Check D4 L2 U12 elf the led 28V is off 1 Check if the led 320V is on if it is ok la Check if U11 is in thermal drift ATTENTION on the heat dissipator there is dangerous tension 1b Check if U5 U6 U7 U8 U9 are in short circuit Switch off the fixture Remove all the chips from the socket Switch on the fixture if the led is on insert the chips one by one in the sockets to find out which is in short circuit 1c Check D3 1d If all the operations described above have not given any positive result change U11 2 Ifthe led 28V is off together with the led 320V 2a Check the MAIN POWER INPUT where you can measure the working voltage 2b Check the main fuse if it is blown check VR1 normally it has a resistance If it is in short circuit you must change it 2c Check D1 Bridge Rectifier if it is ok check C65 2d If the fuse is still blown change U11
6. 5 OPTO DMX TO DISPLAY k 4121 a i E a i i i a LED 40 LED DMX 320V DC 4 1 1 SIGNAL f mare Para D ae F TO HEAD FAN MOT3 aoti 012 MAIN POWER MOT2 MAGENTA YELLOW INPUT LED 28V DIMMER TO 250 MOTS U10 MICRO PWM CYAN FAN CONTROLLER TO BASE FAN TO PCB TO LAMP BOX CYM BOX TO HEAD 250 VRI VARISTOR 275V D3 SAFETY SWITCH THERMAL SENSOR OVERVOLTAGE PROTECTION AND SWITCH D1 OFF LINE BRIDGE RECTIFIER MOTORS BOARD POWER SUPPLY 30V Led On e 5V Led 320V Led 5V DMX Led DMX signal Led flashing the DMX signal is operating on the board Led off check the U1 6N137 and the DMX connecting cable from PCB PAN IP STEPPER MOTOR channel not working i e YELLOW 1 Switch off the fixture and disconnect the YELLOW and CYAN cables 2 Connect the YELLOW cable on the CYAN connector 3 Switch on the fixture 3a If the YELLOW motor works normally it is necessary to replace the U6 L6219 3b If the motor is still not working check with extreme attention the motor and the interconnecting circuits cables and connectors To check the cables and the motors you can measure the resistance as follows between PIN 1 PIN21 on IC U6 r 180hm between 2 PIN5 on IC U6 r 180hm If the led 5V is off 1 Disconnect TO DISPLAY PCB PAN IP connector if the led is
7. FAN connector Check the start up test when switching on the fixture Speed of the head fan is always the same The electronic control of the fan is broken or not correctly connected TO HEAD THERMAL SENSOR connectors are not ok Thermal sensor on the air output broken or disconnected U10 micro on the PCB CCIP broken Check connections from TO HEAD THERMAL SENSOR connector to thermal sensor Check the thermal sensor Check the start up test when switching on the fixture The lamp is cutting out intermittently The lamp is not working well The values reached by the internal temperature are too high The tension of the power supply is either too high or too low The fan on the head is not working regularly The air grilles are stopped up Measure the mains voltage Check and if necessary replace the fan Check and if necessary replace the RFH resistor Clean the grilles One of the function is not working well ie DIMMER Disconnect the power Manually test if the DIMMER moves freely The stepper motor is damaged or the cable connected to the controller pcb is broken ref CCIP PCB The motor drive L6219 is broken Make all the tests reported in page 14 DATA LINK 512 DMX TOUBLESHOOTING Appendix C Table 2 Problem Pilot tests guide Probable cause s Suggested Solutions None of the Citycolors responds to controller The DMX led is s
8. RMINAL LINE WARNING The wrong connection of the terminal line or its non connection are probably the most frequent reasons for the defective functioning of the DMX line The terminator is a resistor fitted between the two data lines pins 2 and 3 of an XLR 5 pin connector at the end of the cable furthest from the transmitter The terminator resistor should have the same value as the impedance of the connection cable We supply a terminal with a 100 Ohm resistor It is recommanded that all DMX 512 systems have the termination resistor at the and of the line TERMINAL RESISTOR EXAMPLE 1 Connection controller spot with 1 DMX 512 output SPOT SPOT SPOT LAST SPOT TERMINAL RESISTOR EXAMPLE 2 Connection controller spot to one DMX 512 output over 150mts long SPOT LAST SPOT DMX CONTROLLER OR LIGHT CONSOLE TERMINAL RESISTOR SIGNAL AMPLIFIER Molde LAMP DIMMER LAMP OFF DMX MASTER pict 7 USE OF THE CITYCOLOR IN AUTO MODE A short list of the games can be found in appendix B page 27 Press the MENU button on the control panel up to when the option MODE pict 7 is shown on the display select it by pressing ENTER and the set indication will appear no SL Use Down and Up buttons to change the mode and once the required one has been selected press and keep ENTER pressed up to when the
9. Safety 2 Technical features page 3 fi Before USING metadis aai di OAE aE 4 Lamp installation replacement and setting 5 I Installation of the dust page 6 Control panel and teat eae page 7 8 z Use of the CityColor 2 2 page 9 DMX signal 10 DMX lime termination 11 2 12 Troubleshooting 13 System board 15
10. cted option is different from the pre set one To go back to the options without making any change press the MENU button Mode Mode To visualise this mode press ENTER Use Down and Up buttons to change the mode and once the required one has been selected press and keep ENTER pressed up to when the display stops flashing it flashes to indicate that the selected option is different from the pre set one The available options are no normal for the functioning in DMX reception 01 15 pre set 01 15 for the master functioning with the re spective game SL slave for the functioning as slave To go back to the options without any change press the MENU button LHrS Lamp Hours To visualise the number of working hours of lamp press ENTER The maximum countable number of hours is 3000 Exceeding this number the display will show gr3t greater than 3 thousands To reset the counter press simultaneously buttons Down and UP the display will show CLLH clear lamp hours To go back to the options without making any change press the MENU button FHrS Fixture hours To visualise the number of working hours of fixture press ENTER The maximum countable number of hours is 3000 Exceeding this number the display will show gr3t greater than 3 thousands To reset the counter press simultaneously buttons Down and UP A control of the memory will be run and all the default settings will be stored the display will then show Init If t
11. current 14A Lighted surface Lxh D 5 Rated power 3000W CITYCOLOR 2500 Beam opening 50 52 36 38 4 e POWER FACTOR CORRECTOR built in cos 0 9 DMX CHANNELS 1 motors speed ch5 dimmer ch2 cyan ch6 basic colors rainbow ie ch3 yellow ch7 remote reset lamp off ch4 magenta 6x6 4 m 1 DIMENSIONS wxdxh mm 780x560x740 Lighted surface Lxn 60568 CITYCOLOR 1800 Beam opening 50527 e WEIGHT art 0002 56 kgs net art 0003 69 kgs net CIRCUIT BREAKER MAINS VOLTAGE 20 INPUT CONNECTOR FOR 1800W Studio Due CITYCOLOR art 0002 Keep at least a distance of 0 5mt between the apparatus and inflammable surface nearby Disconnect the unit from power before servicing PIN CONNECTOR FOR POWER INPUT NEUTRAL L LIVE CONDUCTOR SIZES length lt 20mt 1 GROUND MAINS VOLTAGE CROSS SELECTIONAL AREAS 230V 3X1 5 mm minimum INPUT CONNECTOR FOR 2500W HIGH POWER BEFORE USING The equipment must thed JN WARNING e equipment must be earthed IP 54 rate the equipment must be installed on the horizontal plane Read all cautions and warnings to page 1 prior to install this equipment Particularly read the follow 1 Disconnect power before lamp s replacement or servicing Service personnel 2 Do not open the lamp cover for 300 seconds after switching off 3 Wear gloves an
12. d goggles to re lamping or to work inside the unit Service personnel Before connecting the equipment to the power system make sure that the mains voltage and frequency correspond to rated values CityColor be equipped for a mains voltage 230Vac 50Hz on request 200V 50Hz 208V 60Hz 230V 60Hz 240V 50Hz For a power supply of 100V 120V it is necessary to use one auto transformer with the following features Output voltage 230V Output current 15 for art 0002 Output current 20A for art 0003 The power supply cords construction is shown in pict 1 For connection to the mains supply proceed as pict 1 The equipment must be connected to branch circuit having a circuit breacker 16 Id 0 03A 230VAC art 0002 or In 32A Id 0 03A 230VAC art 0003 a Do not install the spot close to the heat sources Observe minimum distance between the spots of 1 5 meters Do not lay the connection cable on the spot when it is warm b This unit must be positioned as to allow its ventilation Be careful not to acclude the in out ventilating grilles c The unit must be positioned at least 50cm from walls or other flammable surfaces d Observe minimum distance to lighted objects of 5 meters External surface temperature Ta 35 C e After 5 minutes work 75 Once the thermic balance has been obtained Tc 100 C 4 The protection screens the lenses or the ultraviolet filters must be replaced
13. ear the clack of the internal circuit breaker Bad lamp Lamp is too hot to re strike Mains voltage is too low The igniter is not working Wrong ballast wiring Replace the lamp Wait for the lamp cooling Measure the mains voltage Replace the igniter Check the ballast wiring The unit works normally but the lamp does not turn on When switching on you can not ear the clack of the internal circuit breaker The unit is not properly closed cover and or lamp house Fault on wiring PCB switches Check and close all the eight mechanical latches Carry out the tests shown on page 14 The unit works normally but the lamp does not turn on The thermal switch on the head of the fixture is open The last DMX channel on the controller n 7 is set on a value gt 250 Too high temperature inside the head The fan on the head is not working The air in grilles are stopped up The REMOTE LAMP OFF command is on Wait that the lamp housing has cooled down Check and if necessary replace the fan Check and if necessary replace the connettors HEAD FAN BASE FAN THERMAL SENSOR Clean the grilles Set the DMX channel on 0 value Ventilation of the head does not work normally The electronic control of the fan is broken or not correctly connected HEAD FAN connectors on the PCB CC are not ok U10 micro on the PCB CCIP broken Check tension on the TO HEAD
14. ess the MENU button DRIVING THE CITYCOLOR WITH A DMX REMOTE CONTROLLER e Select the requested DMX starting address by operating on the Addr option e Select the requested number of channel with NChn option Connect the DMX signal between the fixture and the controller e Check that the DMX led is flasing DMX signal present If there is no signal you must manually reset by operating the RESET option It is possible to choose a standard configuration occupying 6 DMX channels or a enanched configurationoccupying 7 channels Use the enanched configuration if you want to activate channel 7 which enables the reset of the motors and the switching off of the lamp from the controller 6 7 CHANNELS MODE SELECTION Press the MENU button on the control panel up to when the option nChn is shown on the display select it by pressing ENTER and the set indication will appear 6 or 7 channels If you want to activate channel 7 you must set 6 channels on the display Pass through the numbers by pressing the buttons UP and DOWN once you have set the required number store it by pressing the ENTER button and keep it pressed up to when the display stops flashing the flashing shows that the selected option is different from the one previously stored To exit from the selected option without making any change press the MENU button Here below is shown the complete list of the functions of the CityColor The complete list of the DMX values can be fou
15. he memory is damaged the display will show the message FAIL To go back to the options without making any change press the MENU button nChn Number of Channel To visualise the number of channel press ENTER Use Down and Up buttons to change the channel and once the required one has been selected press and keep ENTER pressed up to when the display stops flashing it flashes to indicate that the selected option is different from the pre set one It is possible to set 6 channels or 7 channels remote reset and remote lamp switch off To go back to the options without making any change press the MENU button teSt Autotest To insert the auto test press ENTER and keep it pressed up to when the display shows the flashing message t on test on To take off the auto test press the MENU button To go back to the options without making any change press the MENU button FLIP Display overturning The display visualisation can be standard or overturned by pressing the ENTER button the two modes will be alternatively visible The selected one will be immediately stored in the spot setting To go back to the options without making any change press the MENU button rSEt Reset To run the complete reset press ENTER and keep it pressed up to when the display shows the flashing message r on reset on Once the reset procedure has been completed the spot will go back to the normal setting To go back to the options without mak ing any change pr
16. ide the support technician with the follow information Customer name Phone number fax number Fixture serial number Message that you displayed on your Citycolor display Description of the problem and the troubleshooting procedures that you have performed so far to diagnose and resolve the fault You can contact your authorized STUDIO DUE dealer or directly STUDIO DUE Technical Service tel 39 0761 352520 or fax 39 0761 352653 e mail service studiodue com or customer studiodue com GENERAL TOUBLESHOOTING Appendix Table 1 Problem Pilot tests guide Probable causes Suggested solutions The unit does not turn on the fans do not work The unit is completely dead Measure the mains voltage on the main connector If you have the right value the main fuses are blown No power Power cord or connectors Main fuses blown Connect power Replace the cables and the connectors Replace the mains fuse The fans work the display is turned off no reset when switching on no light The electronics do not work Check that the leds on the motor board CCIP PCB are turned on particularly check the 5V Short circuit on the 5V line D4 has blown U12 short circuit or blown General test on the 5V line Replace the D4 diode Replace the U12 The unit works normally but the lamp does not turn on When switching on you can
17. nd in appendix A page 26 7 CHANNELS 6 CHANNELS 1 Motor speed 1 Motor speed 2 Cyan 2 Cyan CH 3 Yellow CH 3 Yellow 4 Magenta 4 Magenta 5 Dimmer 5 Dimmer 6 Basic colors rainbow 6 Basic colors rainbow CH 7 Remote reset Lamp off A N WARNING When using CYM color mixing the basic colors channel 6 must be set at 00 DMX value CONNECTION THE DATA LINK DMX 512 PIN WIRE SIGNAL SHIELD GROUND RETURN OV INNER CONDUCTOR DATA COMPLEMENT INVERTED INNER CONDUCTOR DATA TRUE NON INVERTED pict 5a pict 5 The connection of the DM X signal to the CITYCOLOR must be made by using the signal input XLR 5 pin connectors which are located on the control panel of the fixture pict 5 The pin nomenclature of the connectors for the connection to the DMX signal is listed in the table pict 5a In order to avoid any problem in the signal transmission it is warmly suggested to use a cable for high speed data transmission sect gt 2x0 25 gnd If the lines have a total length over 150 200 mts it is suggested to use a signal amplifier art 3004 DMX repeter amplifier The usage of a normal microphonic or audio cable is suggested only for lines max 100 mts long To ensure the IP54 rate you must connect the DMX cable inside the base Use the given cables fixing pict 5b and connect by following the cables numbering pict 5c DMX TE
18. nd rating 5 Do not install the spot close to heat sources Do not lay the connection cable on the spot when it is warm e PROTECTION AGAINST ELECTRIC SHOCK 1 This equipment must be earthed 2 Class equipment The power supply cord includes a protective earthing conductor as part of the cord 3 For connection to the supply mains proceed as pict 1 page 3 The equipment must be connected to branch circuit having a circuit breacker 16 Id 0 03A 230VAC art 0002 or In 32A Id 0 03A 230VAC art 0003 4 Disconnect power before lamp s replacement or servicing Service personnel e PROTECTION AGAINST MECHANICAL HAZARDS 1 Use secondary safety chain when fixing this equipment 2 Hot lamp explosion hazard Do not open the equipment for 300 seconds after switching off 3 Equipment surface may reach temperature up to 100 C Allow about five minutes before handling 4 Replace the lamp if it is damaged or thermally deformed e PROTECTION AGAINST UV RADIATION HAZARDS 1 Do not start on this equipment without lamp enclosure or if the protection screens or ultraviolets screens are damaged 2 The protection screens the lenses or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness has been reduced for example by cracks or deep scratches 3 Do not look directly at the lamp while lamp is on INTRODUCTION Thank you for using our flood projector CityColor The CityColor projects thanks
19. o DMX input e LAMP led flashing the lamp switching off is remotely controlled off lamp switched on DIMMER led flashing the lamp is 33 dimmered off lamp switched on BUTTONS Four buttons are used to programme the spot MENU to select the programming options DOWN to go backward in the selected options e UP to go forward in the selected options ENTER to confirm the selected options DISPLAY Shows the various menus and the selected options SUMMARY OF THE PROGRAMMING FUNCTIONS OF THE CITYCOLOR al 3 Addr nChn 2 T teSt lt F LHrS F E v 3 z T FHrS ret About twenty seconds after the switching on the number of the software version will be shown on the display in X_00 format Afterwards the first of the eight available menus will appear Addr to assign the DMX 512 address Mode DMX512 mode master with pre set selection slave LHrS lamp working hours FHrS fixture total working hours nChn channels number teSt auto test FLIP display inversion rSEt reset of the spot To select any of the given options press the MENU button up to when the required one is shown Addr Address To visualise the DMX address press ENTER To modify the address press Down and Up buttons and once the required address has been selected press and keep ENTER pressed up to when the display stops flashing it flashes to indicate that the sele
20. te of the CityColor comes supported at these conditions the installation of the fixture on a wide and stable surface the air cooling input and output are located on the base of the side shell it is not possible to install the fixture outdoor with the ballast upwards e you must use the filter supplied with the basic kit for the IP RATE 54 JN WARNING The CityColor has a IP rate 44 without filters installed and an IP RATE 54 with filters installed You must use the filters in critical working conditions and normally when the fixture works outdoor You must remove the filters when the ambient temperature is over 35 C You must regularly clean the filters to allow the correct cooling of the fixture INSTALLATION OF THE DUST PROOF FILTERS AN WA RNING You must operate with power supply disconnected from the fixture You must remove the two side protective shells The two filters must be assembled on the bulkheads at the bottom of the side brackets pict 3 Pay attention to the installation dust proof filters must stick correctly to prevent the entrance of the dust You must control that the two filters comple tely cover the overall of the air entrance LAMP DIMMER S LAMP OFF DMX 2 pict 4 CONTROL PANEL On the control panel of the CityColor pict 4 you can find besides the display the leds and the buttons to use to set the spot LED e DMX led flashing DMX input present off n
21. to an extremely efficient optic system international patent n WO99 40361 a powerful light beam which can create numberless color shades Its performances in terms of luminousity and lighted surfaces can reach incredible levels The CityColor IP54 comes in the following versions Art 0002 CITYCOLOR IP54 1800W Art 0003 CITYCOLOR IP54 2500W High Power The CityColor can work in automatic mode or in synchro mode otherwise may be controlled by 8 bit DMX controllers The input protocol is the DMX 512 To drive the CityColor we suggest to use either our controller DMX Control Spot the Control Show 512 the Easy Control or the Fancy To make the most of its possibilites and for a correct functioning of this unit in the years to come we suggest you to read carefully this manual before connecting or putting the spot into use By doing so you will gain experience with its commands and connections and you will be easily able to use it JN WARNING Check that the spot has not been damaged during transport If it has been damaged or it does not work address the seller Whether the spot has been shipped to you directly please contact the shipping company Only the consignee person or company can claim for these damages YOUR REFERENCE Always remember to give the serial number and to specify the model any time you address the seller for information or assistan ce BASIC KIT The basic kit of the CityColor flood projector consist of
22. witched off Make sure that all the units are set in DMX mode After the configuration reset all the fixtures The controller is not connected to the fixtures The cable from the controller to the first of the Citycolor is interrupted or pin 2 and 3 are swapped or the cables are on short circuit Connect the controller properly Use an already tested cable and connect the fixtures one by one One or more of the Citycolors do not respond to the controller or do it wrongly The non working fixtures are always the same The fixtures work accidentally If one of the connecting cables is missing this may cause a random malfunctioning in addition to apparent normal operation If the inverted data is cut wire is cut pin 2 on the DMX connector the line works intermittently Wrong DMX address in the fixture Wrong data cables or disconnected or shorted One fixture has a broken DMX board DMX link not terminated Set the proper address Check and if necessary replace the cables Use a tested cable and replace only one ata time Use a tested cable and exclude only one fixture at a time Insert the terminator on the last fixture pag 10 MAIN BOARD CONNECTION U5 U6 U7 U8 09 16219 MOTOR DRIVER U4 MICRO SLAVE MOTOR U11 VIPER SWITCHING CCSLAVEXX U3 MICRO MASTER MOTOR POWER SUPPLY DRIVER CC3DRVXX LED 5V LED 5V DMX U13 78M 0
Download Pdf Manuals
Related Search
Related Contents
Empire ECS HearthRite HR25ML Heater Edge -- User Guide. Produced from Rev: 1069 Méthode adoptée pour la délimitation des aires paysagères Cables Direct 0.5m LC-SC 50/125 OM3 Le Moniteur d`Issoire 1900-08-22 page 02 WMV860 Kullanım Kılavuzu – İndirmek için buraya CellPipe 22A-GX ADSL Ethernet Router User Manual SuperBrain User Manual 09.04.2012 Copyright © All rights reserved.
Failed to retrieve file