Home
Loop-IP6702 TDMoEthernet
Contents
1. Loop IP6702 TDMoEthernet Description The Loop IP6702 device allows operators to transport Unframed 1 or 2 E1 1 or 2 Unframed T1 data stream with timing information over PSN Packet Switched Network via Pseudowire Protocol SAToP Another IP6702 converts the received packet stream back to original E1 or T1 data stream with original timing information This allows cost effective migration from existing legacy TDM networks to Packet Switched Network On the Network side the WAN interface can be either 10 100M BaseT Electric or 100 BaseFX Optical On the TDM Service side the TDM ports can be one or two Unframed E1 and one or two Unframed T1 Two Ethernet LAN ports are also available for Ethernet data traffic For transport of TDM E1 T1 signals the Jitter and Wander performance adheres to G 823 Traffic Interface 1ppm Features Mechanics and Electrics e ANSI shelf e Power Fixed AC Fixed DC Combined AC and DC AoD WAN Interface e On board 10 100 BaseT Electrical Ethernet e On board 100 BaseFX Optical Ethernet User Tributary Interface e TDM Tributary interfaces up to 2 E1 or2 T1 Unframed mode Ethernet Tributary interfaces 1 x 10 100 BaseT Ethernet port plus 1 user selectable 10 100 BaseT Ethernet SNMP port Future Option L2 Switching e Jumbo frame size up to 2048 bytes e VLAN Maximum 4K VLAN ID Maximum 16 con current VLAN Groups Support C VLAN S VLAN tag adding and removing on Ps
2. IEEE ITU 802 1p Priority Code Point G 703 E1 DS1 802 1q VLAN Tagging G 706 Frame Alignment and CRC 802 1ad Q in Q G 823 Traffic and Synchronous Interface G 824 Traffic only 802 31 10BaseT G 826 End to End Error Performance 802 3U 100BaseT 100 BaseFX PWE3 Pseudo Wire Emulation Edge to Edge IETF MEF RFC 3411 SNMPVvI v2c v3 8 CESoETH RFC4553 SAToP RoHS Restriction of Hazardous Substances Directive Certifications EMC EN55022 Class A EN50024 EN300 386 FCC Part 15 Subpart B Class A Safety IEC60950 1 CB EN60950 1 CE Future option Loop 1P6702 TDMoEthernet TDMoE Panel Views Front Panel View 3 Telecom Loop 1P6702 TDMoEthernet TDMoE Application Illustrations Point to Point Application IP6702 IP6702 E1 T1 I dina i gt GG MOI TT e E1 T1 LAN LAN2 LAN2 SNMP LAN 10 100 BaseT 10 100 BaseT Management Point to Multipoint Application P6702 E IP6702 ee ai LAN1 EVTI qa mR TT FRE LAN2 IP Networ E1W T1I Gea eee 2 ww we Qe www ww we ee 3 96762 1 17 LAN 10 100 BaseT LAN1 af ae li LAN2 Management Loop 1P6702 TDMoEthernet TDMoE E1 LAN Ethernet Radio Application W8140 W8210 W8140 W8210 Ethernet Ethernet IP6702 IP6702 om ERT BID sh th E1 LAN1 LAN2 SNMP E1 LAN1 LAN2 SNMP E oop LOOP TELECOMMUNICATION INTERNATIONAL INC Pe ISO 9001 ISO 14001 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F N
3. e 1 544 Mpbs 32 ppm Output Signal DSX 1 DS 1 Line Code AMI B8ZS Jitter and Wander AT amp T TR 62411 Framing None Connector RJ48C Timing Source Primary Secondary Clock Internal 20 ppm E1 T1 line Adaptive Clock Recovery Alarm Relay Alarm Relay Fuse alarm performance alarm Connector 3 pin terminal block Maximum Current 1A for 30 Vdc Network Management Console Port SNMP Port Electrical RS232 interface Protocol SNMP v1 Terminal Menu driven VT 100 Connector RJ45 at front panel Connector DB9 female and DCE Performance Monitors E1 T1 Performance Store The last 24 hours performance in 15 minute intervals Performance Reports Date amp Time Error Second ES Unavailable Second UAS Bursty Errored Second BES and Severe Error Second SES Alarm Reports E1 T1 Alarm History Date amp time alarm type i e clock loss LOS BPV ES Alarm Queue Contains up to 160 alarm records of latest alarm types alarm severity date and time Diagnostics Test E1 T1 Loopback Line loopback and Local loopback Power Physical and Environmental AC fixed module 100 to 240 Vac Dimensions 210 x 41 5 x 140 mm W x H x D DC fixed module 42 to 72 Vdc Net Weight 1 0 Kg AC amp DC 100 to 240 Vac and 42 to 72 Vdc Temperature 0 50 C Consumption Maximum 5 0 W Humidity 0 95 RH non condensing Mounting Desk top stackable wall mountable rack mount with 19 tray available Standards Compliance
4. eudowire Support 802 1q Port Based VLAN on Ethernet SNMP Port Support Q in Q Support Multiple Bridge Groups Support 802 1d MAC Learning Support 803 3x Flow control on input ports Packet Transparency QoS e IP Network Level 6 bit DiffServ Code Point DSCP field ToS Pseudowire Capability Support SAToP Support E1 T1 traffic emulation over UDP IP Network Maximum 2 Pseudowires PDV Compensation Depth up to 512 ms Jitter Buffer Size up to 1024 frames Excel calculator is provided Pseudowire Diagnostic Function Built in BERT for E1 T1 to Line or WAN direction ARP Ping and Trace Route IP MAC Table Display Pseudowire Information Packet Creation Time ms Jitter Tolerance Delay ms Single Trip Delay ms Total Frame Length bytes Packet per second Required Bandwidth Mbps Header Overhead Jitter amp Wander PPM version conforms to G 823 Traffic Interface 1ppm Timing Reference Be Ts t a Internal 20 ppm 3 Line E1 T1 Adaptive Clock Recovery All Pseudowires can apply ACR OAM Capability Support 1 SNTP timing reference Alarm propagation between E1 or T1 to line and WAN port Multi color LED indicators Alarm relay ACO Alarm Cutoff button Management Interfaces 1 user selectable Ethernet SNMP port SNMP v1 v3 with 5 SNMP trap IP DB 9 Console port with VT 100 menu Telnet and SSHv1 SSHv2 C VLAN S VLAN tag on management traf
5. fic LoopView GUI Standards Compliance SATOP Future Option Loop 1P6702 TDMoEthernet TDMoE Ordering Information Note RoHS compliant units are identified by the letter G appearing immediately at the end of ordering code Main Unit Model Description Notes Loop 1P6702 S ETH PPM 1aa pp G IP6702 with G 823 traffic interface e Where aa and pp are defined 1 electric Ethernet WAN port 1 LAN port below 1 SNMP port and 1x E1 or 1x T1 port e For other special optical Loop IP6702 S ETH PPM 2aa pp G IP6702 with G 823 traffic interface MOC S PIP AE Comic Orr nearest Loop sales representative e Low Speed for E1 T1 1 electric Ethernet WAN port 1 LAN port 1 SNMP port and 2x E1 or 2x T1 ports Loop 1P6702 S SFPH PPM 1aa pp G IP6702 with G 823 traffic interface 1 SFP mini GBIC optical housing for WAN port SFP optical module not included 1 LAN port 1 SNMP port and 1x E1 or 1x T1 ports Loop 1P6702 S SFPH PPM 2aa pp G IP6702 with G 823 traffic interface 1 SFP mini GBIC optical housing for WAN port SFP optical module not included 1 LAN port 1 SNMP port and 2x E1 or 2x T1 ports m Where aa is used to select connector This module must be selected one from the list below aa Description Notes E75 E1 75 ohm with RJ48C connector e 75 ohm 120 ohm is software selectable E120 E1 120 ohm with RJ48C connector e Please order RJ48 to BNC conversion cable TI T1 with RJ48C connector m Where pp is used to select powe
6. o 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Hsinchu Science Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China 886 3 578 7696 886 2 2659 0399 1 561 627 7947 86 22 8789 4027 www looptelecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2013 Loop Telecommunication International Inc All Rights Reserved Version6 8 May 2013 Subject to change without notice
7. r module This module must be selected one from the list below pp Description Notes AoD AC 100 to 240 Vac e For DC wire to included IEC socket 48Vdc DC 42 to 72 Vdc SI Both are not powered simultaneously Support sealing e No safety certification for DC current looped e For AC choose an appropriate power cord AC 100 to 240 Vac DC 48Vdc 42 to 72 Vdc Accessories User s Manual Loop IP6702 UM User s Manual paper hard copy optional A CD version of the manual is already included as standard equipment Firmware Upgrade Loop IP6702 FWUPGR Firmware Upgrade Customers who desire to have a firmware upgrade after their warranty has expired can purchase this option This will upgrade the firmware to the most current version and provide an additional 12 months of software repair and patches on existing functionality as necessary Loop 1P6702 TDMoEthernet TDMoE Power Cord All power cords are RoHS compliant Loop ACC PC USA AC power cord for Taiwan America l a Loop ACC PC EU AC power cord for Europe e Loop ACC PC UK AC power cord for UK w Ns Loop ACC PC AUS AC power cord for Australia I Loop ACC PC CH AC power cord for China I N I Conversion cable Loop ACC CAB RJ48M 28 2BNCF G RJ48C Male to BNC Female 2 Conversion cable Length 28 cm Tray 81 TRAY19 1000 G 19 Tray for rack mount One tray for two base units SFP Optical Modules Please place your order using the 5 digit alphanumeric codes li
8. sted in the separate SFP Optical Module Brochure Examples 1 Main unit Loop IP6702 S ETH PPM 1E75 AC G Accessory Loop ACC CAB RJ48M 15 2BNCF G Description IP6702 stand alone unit with G 823 traffic interface 1 electric Ethernet WAN port 1x E1 75ohm interface port 100 to 240 Vac power Examples 2 Main unit Loop IP6702 S SFPH PPM 2E120 DC G Description IP6702 stand alone unit with G 823 traffic interface 1 SFP optical housing for WAN port 2x E1 1200hm interface ports 42 to 72 Vdc power Specifications SFP Optical Module Please refer to SFP optical module brochure for detail WAN Interface Number of Ports 1 Electrical port or 1 Optical port Electrical Port Optical Port Speed 10 100 BaseT Speed 100 BaseFX 802 3i 802 3u 802 3u Auto negotiation 10 100 Connector SFP Auto MDI MDIX Full Half Duplex Connector RJ45 Ethernet Tributary Interface Number of Ports 2 Speed 10 100 BaseT 802 3i 802 3u Auto negotiation 10 100 Auto MDI MDIX Full Half Duplex Connector RJ45 E1 Tributary Interface Number of Ports 2 Input Signal ITU G 703 Line Rate 2 048 Mbps 50 ppm Output Signal ITU G 703 Line Code AMI HDB3 Jitter and Wander ITU G 823 traffic mode Framing CCITT G 704 Impedance 75 ohm coax 120 ohm twisted pair programmable Connector BNC and RJ48C Loop 1P6702 TDMoEthernet TDMoE T1 Tributary Interface Number of ports 2 Input Signal DS 1 from 00B to 26 dB w ALBO Line Rat