Home
CL2X16-D1C3V CC-Link/LT Remote I/O Module User`s Manual
Contents
1. CC Link LT CL2X16 D1C3V meres Insulation TON P 2 DA EREGI DCDC 4 24G es pe Connector for ttm VO interface CON1 1 2v that S 3 246 4 3 wire sensor orecsor a 0 H i Sink output e cut aay NPN output type A K t Ks ig 2 wire sensor E Sink output A K g i l i Sink output 7 24V i i 2v i i o 3 as i 4 XF Hr 1 Z AVERTISSEMENT Storage 25 to 75 C bient Ne pas toucher aux broches de connecteur quand l appareil est sous tension Cela feniperatil re pourrait tre a l origine d un choc lectrique ou d un dysfonctionnement z Avant de nettoyer le module v rifier sur l alimentation externe a bien t coup e Operating 5 to 95 RH non condensing sur toutes les phases ambient Faute de quoi il y a risque de panne ou de dysfonctionnement des modules humidity Storage PRECAUTIONS DE DEMARRAGE ET DE MAINTENANCE ampient umidity A ATTENTION Vibration Compliant Frequency Constant Half Sweep Ne pas d monter ni modifier le module Cela pourrait tre l origine de pannes de resistance with JIS B acceleration amplitude count dysfonctionnements de blessures ou d un d part de feu 3502 and Under 5 to 8 4Hz 3 5mm 10 times Ne pas faire tomber ou soumettre le module a des ch
2. LINK PW Bl o N gt o w 24G Connector for CC Link LT interface Pin No Signal name Connecteur pour interface CC Link LT Broche N Nom de signal Operating Confirmation details status name indicator py LEDs On Power supply on Off The power supply is turned off or the voltage drop is too large Effectuer l installation et le c blage apr s avoir d connect l alimentation externe sur toutes les phases Si l alimentation n a pas t coup e sur toutes les phases il y a risque d lectrocution ou d endommagement du produit PR CAUTIONS DE C BLAGE ATTENTION C bler le module correctement apr s v rification de la tension nominale du produit et de l affectation des broches de connecteur Le raccordement d une alimentation de tension nominale diff rente ou une erreur de c blage peuvent tre a l origine d un d part de feu et ou d une panne du produit Veiller viter toute p n tration d impuret s copeaux de c blage ou autre corps tranger dans le module Cela pourrait tre l origine d un d part de feu ou du panne ou d un dysfonctionnement du produit 1 Operating L RUN On Normal communication status Off Communication cutoff time expiration error indicator L ERR On Indicates that a communication data error has LEDs occurred or the setting switch is outside the allowable ran
3. CL2X16 D1C3V CC Link LT Remote I O Module Thank you very much for purchasing this product Please read this manual thoroughly before starting to use the product and handle the product properly User s Manual MODEL CL2X16 D1C3V U MODELCODE 13JP25 IB NA 0800258 C 1406 MEE 2003 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS Read these precautions before using Please read this manual carefully and pay special attention to safety in order to handle this product properly Also pay careful attention to safety and handle the module properly These precautions apply only to Mitsubishi equipment Refer to the user s manual of the CPU module to use for a description of the programmable controller system safety precautions In this manual the safety precautions are classified into two levels A WARNING and A CAUTION WARNING Indicates that incorrect handling may cause hazardous conditions resulting in death or severe injury A CAUTION Indicates that incorrect handling may cause hazardous conditions resulting in minor or moderate injury or property damage A AVERTISSEMENT Attire l attention sur le fait qu une n gligence peut cr er une situation de danger avec risque de mort ou de blessures graves Attire l attention sur le fait qu une n gligence peut cr er une situation de danger avec risque de blessures l g res ou de gravit moyennes ou risque de d g t
4. 60Hz noise simulator condition First transient noise burst IEC 61000 4 4 1kV Withstand voltage 500V AC for 1 minute between primary external DC terminal and secondary internal circuit Insulation resistance 10MQ or more between primary external DC terminal and secondary internal circuit when measured with a 500V DC insulation resistance tester Protection class IP2X WARRANTY Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 I 20041 Agra
5. Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 A MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Germany France South Africa China Taiwan Korea Singapore Thailand Indonesia Australia When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice
6. or Hazardous Materials or Chemicals Mining and Drilling and or other applications where there is a significant risk of injury to the public or property Notwithstanding the above restrictions Mitsubishi may in its sole discretion authorize use of the PRODUCT in one or more of the Prohibited Applications provided that the usage of the PRODUCT is limited only for the specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail safe redundant or other safety features which exceed the general specifications of the PRODUCTs are required For details please contact the Mitsubishi representative in your region 8 1 Overview This user s manual explains specifications and names of individual parts of the CL2X16 D1C3V type CC Link LT remote I O module hereinafter abbreviated as remote I O module 2 Specifications 2 1 General Specifications The General specifications for the remote I O module are shown in the following table 0 to 55 C 0a55 C Operating ambient temperature Temp ratur e ambiante de fonctionne ment All 24G pin are connected within the module common The module power and external power supply of the input part are supplied via the power adapter Toutes les broches 24G sont connect es l int rieur du module commun L alimentation du module et l alimentation externe de la partie entr e se font via l adaptateur d alimentation 3 wire
7. 0 J20 i0 f8 4 2 1 SW1 Sw2 Sw3 sw4 SWS swe SW7 32 OFF ON ON OFF OFF ON OFF 4 Connector Connector for connecting the CC Link LT communication line for CC module power supply and external power supply of the input part Link LT interface 5 Connector Sensor connector for connecting input signals for I O interface 6 Hook for DIN rail 1 Set up using a slotted screwdriver with a tip width of 0 9 mm or less 4 Handling Precautions Hook for installing the module on a DIN rail 1 When using a DIN rail attach the DIN rail after taking the following items into consideration Applicable DIN rail types conform to JIS C 2812 TH35 7 5Fe TH35 7 5Al Interval between the DIN rail s installation screws Tighten the screws using a pitch of 200mm 7 87in or less when attaching a DIN rail 2 To attach the remote I O module to the DIN rail press the centerline area of the DIN rail hook beneath the module until a click is heard 3 When installing the remote I O module into a panel etc provide 15mm 0 59 in or more of space between the top and bottom of the module and other structures or parts so that good ventilation and ease of operation when exchanging modules can be secured 5 Wiring 5 1 External wiring Connector for
8. attached to the plug unit as shown in the figure at right Point While performing pressure displacement the plug cover may rise because it is not latched against the plug unit correctly This condition indicates that pressure displacement is incomplete Push the plug cover until it is securely installed in the plug unit 6 External Dimensions 39 1 54 48 1 89 WERE cias orev 0 amp TEN z m Eh z i Center of DIN rail P DNI J 8 4 NJ S 4 2 76 a k MITSUBISHI i lt E e Unit mm inch 1 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the rated voltage of 300V is 2500V 2 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used Pollution level 2 is when only non conductive pollution occurs A temporary conductiv
9. de fa on maintenir la s curit de fonctionnement du syst me dans l ventualit d un probl me de communication affectant la liaison de donn es Faute de quoi une sortie erron e ou un dysfonctionnement pourrait tre l origine d accidents L entr e peut tre activ e ou d sactiv e la survenance d un probl me dans les modules E S distants On constituera donc un circuit de surveillance externe couvrant tous les signaux d entr e qui pourraient tre l origine d un accident grave PR CAUTIONS DE CONCEPTION ATTENTION Ne pas grouper ni placer proximit les c bles de commande ou c bles de communication avec les cables des circuits principaux et ou d alimentation Cabler en pla ant ces cables a une distance d au moins 100mm 3 94 pouces des cables des circuits principaux ou de l alimentation Cela pourrait tre a l origine d un bruit parasite entrainant des dysfonctionnements PRECAUTIONS D INSTALLATION ATTENTION Utiliser le module dans un environnement conforme aux sp cifications g n rales pr sent es dans ce manuel L utilisation de ce module dans un environnement autre que celui pr vu dans les sp cifications g n rales peut tre a l origine d un choc lectrique d un d part de feu ou d un dysfonctionnement ou peut endommager ou d t riorer le produit Eviter tout contact direct avec les parties conductrices du module Cela pourrait tre a l origine de dysfonction
10. ge Flicker at regular intervals Indicates that the setting switch has been changed while current is being conducted The module continues to operate even while the LED is flickering The changed settings will be reflected when the power has been restored Flicker at irregular intervals Indicates that the terminal resistor is left unconnected or that the module or connection cable are affected by noise Off Normal communication QtoF Displays the ON OFF status of the input turned on in the ON status and turned off in the OFF status 2 Response Set the response time OFF ON ON gt OFF time of the remote time I O module setting OFF is set as default factory set switch Noise may be taken in as input if high speed response type is set SW8 Be sure to set response time in consideration of the environment ON 0 5ms High speed response type OFF 1 5ms Standard type 3 Station Select 10 20 or 40 to set the ten s place of the station number number Select 1 2 4 or 8 to set the one s place of the station number setting All switches are set to OFF at shipment from the factory switches Always set the station number within the range of 1 to 64 SW1 to 7 A setting error occurs and L ERR LED flickers if the value outside the range 1 to 64 is set Example Set the switches as below when setting the station number to 32 Station Ten s place One s place number 4
11. ing or miss wiring may cause fire and or product failure Make sure foreign objects do not get inside the module such as dirt and wire chips It may cause fire product failure or malfunction STARTING AND MAINTENANCE PRECAUTIONS A WARNING Do not touch the connector pins when the power is on It may cause an electric shock or malfunction Before cleaning the module be sure to shut off all the phases of the power supply externally Failure to do so may cause failure or malfunction of the modules STARTING AND MAINTENANCE PRECAUTIONS A CAUTION Do not disassemble or modify the module Doing so may cause failure malfunction injury or fire The module case is made of resin do not drop it or subject it to strong shock A module damage may result Make sure to switch all phases of the external power supply off before installing or removing the module to from the panel Failure to do so may cause failure or malfunction of the modules Before touching the module always touch grounded metal etc to discharge static electricity from the human body etc Not doing so can cause the module to fail or malfunction DISPOSAL PRECAUTIONS A CAUTION When disposing of this product treat it as industrial waste PRECAUTIONS DE CONCEPTION A AVERTISSEMENT Pr voir dans le programme s quentiel un circuit de verrouillage sur la base des informations d tat de la communication
12. ity caused by condensing must be expected occasionally 3 It can also be used in an environment other than on the control panel if the conditions such as usage ambient temperature and humidity are satisfied 2 2 Performance specifications The performance specifications for the remote I O module are shown in the following table 16 points Number of inputs Isolation method Photocoupler isolation Rated load voltage 24V DC Common with the module power supply Rated input current Approx 4mA Max simultaneous ON input 100 points ON voltage ON current 19V or higher 3mA or higher OFF voltage OFF current 11V or lower 1 7mA or lower Input resistance 5 6kQ Response Response time 0 5ms High speed 1 5ms Standard type time setting response type OFF TYP 0 05ms ON MAX _ 0 1ms 1 5ms ON gt TYP 0 2ms OFF MAX 0 5ms 1 5ms Common wiring method 16 points 1 common sensor connector 3 wire type Input method Positive common Number of stations occupied In 4 point mode Occupies 4 stations In 8 point mode Occupies 2 stations In 16 point mode Occupies 1 station Module Voltage 24V DC 15 to 20 ripple ratio within 5 power supply Current 45mA or lower When 24V DC and all point is on consumption Currenton 70mA or lower 24V DC startup Noise durability DC type noise voltage 500Vp p noise width 1s noise carrier frequency 25 to
13. nements ou autres probl mes avec le module Fixer fermement le module en place sur le rail DIN Si le module n est pas fermement fix il risque de tomber ou il peut y avoir des dysfonctionnements PRECAUTIONS DE CABLAGE N AVERTISSEMENT A CAUTION Use the module in an environment that meets the general specifications contained in this manual Using this module in an environment outside the range of the general specifications could result in electric shock fire erroneous operation and damage to or deterioration of the product Do not directly touch the module s conductive parts Doing so could cause malfunction or trouble in the module Securely fix the module in place using the DIN rail If the module is not securely fixed it may fall off or cause malfunction WIRING PRECAUTIONS A WARNING Perform installation and wiring after disconnecting the power supply at all phases externally If the power is not disconnected at all phases an electric shock or product damage may result Weight I O part connection method 0 08kg Open sensor connector e CON x 16 Connector plugs are sold separately compatible wire size 0 08 to 0 5 mm depending on the connector plug used Refer to the CC Link LT Catalog DIN rail installation Can be installed in six directions Module installation method 3 Part Names This section explains the names of the components for the rem
14. ocs car son bo tier en IEC intermittent gq 4 9 8mis each in plastique est fragile Il pourrait en r sulter un endommagement du module 61131 2 Vibration i pat ems a X Y Z Avant d installer le module dans le tableau ou de l en retirer il est indispensable de 7 directions couper l alimentation externe sur toutes les phases Faute de quoi il y a risque de panne ou de dysfonctionnement des modules banal 5 to 8 4Hz 7 175mm j Avant de toucher au module se d barrasser de la charge lectrostatique Sieg SIGE 8 4 to 4 9m s qu accumule le corps humain en touchant un objet m tallique raccord la terre vibration 450Hz Le non respect de cette pr caution peut tre l origine de pannes ou de Shock Compliant with JIS B 3502 and IEC 61131 2 dysfonctionnements du module resistance 147 m s 3 times each in 3 directions X Y Z Operating No corrosive gases PRECAUTIONS DE MISE AU REBUT atmosphere ATTENTION Operating 0 to 2000m Lors de sa mise au rebut ce produit doit tre trait comme un d chet industriel atitude z Installation Inside a control panel 3 CONDITIONS OF USE FOR THE PRODUCT location Overvoltage I or less category 1 Mitsubishi programmable controller the PRODUCT shall be used in Pollution 2 or less conditions degree i where any problem fault or failure occurring in the PRODUCT if any shall not lead to any major or serious accident and ii where the backup and fail safe function a
15. ote I O module 12345678 N ene T 4 mE EA y x M aaa e ma e ma e EEEE 2 CEEE A CEEE I gt EEE B 5 E0BE 4 EEEE kg mnan gt CEEE B EEEEI id EEEE e EEEE z EEEE id MITSUBISHI 6 1 1 1 1 2 V 2 V 2 V 2 V 3 24G 3 24G 3 24G 3 24G ih ast 4 1x0 4 x4 4 X8 4 xC pos co 1 24v CO 1 24v Co 1 24v CO 1 24V com N2 Ffy ING Ialay N1 Talay N14 ilav EEEE fron 324G 3 246 alaae 3 24G ee faix 4 x5 4 x9 4 xD Tma coms heon CO 1 24V CO 1 24V CO 1 24V CO 1 24V cons N3 2 V N7 2 V Na 2 V N15 2 V BEER conse 3 246 3 24G 3 246 3 24G 4 x2 4 x6 4 XA 4 XE co 1 24v CO 1 24v CO 1 24vV cO 1 24V N4 f2fav N8 olay m 2 av M16 fa fav 3 246 3 24G 3 246 3 24G 4 1x3 4 Xx7 4 XB 4 XF Connector for I O interface Pin No Signal name Connecteur pour interface E S Broche N Nom de signal
16. re systematically or automatically provided outside of the PRODUCT for the case of any problem fault or failure occurring in the PRODUCT The PRODUCT has been designed and manufactured for the purpose of being used in general industries MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY INCLUDING BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON CONTRACT WARRANTY TORT PRODUCT LIABILITY FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATED OR USED IN APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS PRECAUTIONS OR WARNING CONTAINED IN MITSUBISHI S USER INSTRUCTION AND OR SAFETY MANUALS TECHNICAL BULLETINS AND GUIDELINES FOR the PRODUCT Prohibited Application Prohibited Applications include but not limited to the use of the PRODUCT in Nuclear Power Plants and any other power plants operated by Power companies and or any other cases in which the public could be affected if any problem or fault occurs in the PRODUCT Railway companies or Public service purposes and or any other cases in which establishment of a special quality assurance system is required by the Purchaser or End User Aircraft or Aerospace Medical applications Train equipment transport equipment such as Elevator and Escalator Incineration and Fuel devices Vehicles Manned transportation Equipment for Recreation and Amusement and Safety devices handling of Nuclear
17. s mat riels Under some circumstances failure to observe the precautions given under N CAUTION may lead to serious consequences Observe the precautions of both levels because they are important for personal and system safety Make sure that the end users read this manual and then keep the manual in a safe place for future reference A ATTENTION DESIGN PRECAUTIONS A WARNING Configure an interlock circuit in a sequence program so that the system operates on the safety side using the communication status information in the event the data link falls into a communication problem Otherwise erroneous output and malfunction may result in accidents Input could be switched on or off when a problem occurs in the remote I O modules So build an external monitoring circuit that will monitor any input signals that could cause a serious accident DESIGN PRECAUTIONS A CAUTION Do not have control cables and communication cables bundled with or placed near by the main circuit and or power cables Wire those cables at least 100mm 3 94 inch away from the main circuit and or power cables It may cause malfunction due to noise interference INSTALLATION PRECAUTIONS WIRING PRECAUTIONS PRECAUTIONS DE DEMARRAGE ET DE MAINTENANCE A CAUTION Wire the module correctly upon verifying the product s rated voltage and the connector pin arrangement Connecting to a power supply different from rat
18. sensor Sink output NPN output Capteur 3 fils sortie dissipateur type type sortie NPN 2 wire sensor Sink output Capteur fil 2 sortie dissipateur Connector for CC Link LT interface Connecteur pour interface CC Link LT Connector for I O interface Connecteur pour interface E S Sink output Sortie dissipateur Insulation Isolation 5 2 Connection and wiring of the connector for I O interface Wire the connector for I O interface according to the following procedure Verify that the plug cover is installed in the plug unit Caution Do not push the plug cover into the plug unit before the cable is inserted Once a plug is pressure displaced it can no longer be reused Insert the cable until it makes contact with the plug unit Point When inserting the cable confirm that it has been inserted completely If the cable is not inserted completely it may cause contact failures If the cross section of the cable is not round the cable cannot be inserted smoothly Cut the cable tip using pliers etc and make it as round as possible then insert it When inserting the cable the cable may stick out from the front of the cover In such a case pull the cable backward so that the tip of the cable stays within the plug cover Using a pliers or special tool push the plug cover into the plug unit and pressure displace it After performing pressure displacement verify that the plug cover is securely
19. te Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Mitsubishi Electric Automation China Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2480 Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M I D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Mitsubishi Electric Australia Pty Ltd 348