Home
User Manual - Weighing machines Services Ireland
Contents
1. 700D Alternative power supply 1 3 D size dry batteries 4 5V 2 6V 300mA adaptor Optional JWI 700S Alternative power supply 1 4 pieces of solar energy panel 2 3 7V 2000mA Li ion battery 3 6V 300mA adaptor Optional JWI 700D 700S Low bat When changed ry warning appears in the upper left corner of the weight window the battery requires to be 4 Installation 4 1 Load cell connection LOAD CELL BIN 0 SIGNAL LOAD CELL Eo d Ek Oo 2 E SHIELD 4 2 Assembly Description of Upright Pole 2 8 4 1 Rod seat 2 Upright pole 3 Racket 4 Indicator 5 Screw for fixing the upright pole 6 Screw for fixing bracket 7 Knob pole 8 Bracket slot 9 Load cell wire Q A A A A A Gm A Step 1 Thread the wire of the Load Cell 9 on the rod seat 1 through the upright pole 2 Insert The upright pole into the rod seat and then Lock it with two screws 5 Step 2 After threading the Load Cell wire Through the bracket 3 attach the bracket to the Upright pole and then lock it with the screw 6 Note if the load cell connector is too big to thread through the bracket separate the bracket by removing the Knob pole 7 see the following pictures JWI 700D 700S 6 otep 3 Install the Indicator 4 on the bracket with the bracket aligning with the bracket slot 8 of the indicator otep 4 After connecting load cell connector to load cell port the installa
2. Long press key TARE for 3 seconds The scale is now in digital inputting mode with the JWI 700D 700S 12 left most digit blinking Press MRH or TARE to move the key leftwards or rightwards Press PRINT HI or IHOLD LO to change the value E g here we set the Preset Tare value as Press key M SET to save and return to weighing mode L Put the load on the container the scale will automatically deduct the value of the container from the total value To clear tare with an empty pan press down key TARE or key ZERO ESC 7 3 Check Weighing Lower limit setting 1 3 4 Begin by pressing down key HOL D LO It is now in digital inputting mode with the left most digit blinking To set the value of lower limit press MH or TARE to move the key leftwards or rightwards Press PRINT HI or HOL D LO to change the value Press M SET to enable disable the check weighing function Press M SAVE to save the Lower limit and return to weighing mode Upper limit setting 1 2 Begin by pressing down key PRINT HI It is now in digital inputting mode with the left most digit blinking To set the value of lower limit press MR a or TAHE amp to move the key leftwards or JWI 700D 700S 13 rightwards Press PRINT HI or HOL D LO to change the value 3 Press M SET to enable disable the check weighing function 4 Press M SAVE to save the Lower limit and return to weig
3. read the manual completely before installation and operation 2 Precautions e Place the indicator on a flat and stable surface e Verify that the input voltage and the plug type matches the local AC power supply see 3 4 e Warn up for 15 minutes before using it the first time Keep the indicator away from EMI noise strong wind and vibration which might cause incorrect reading Avoid sudden temperature changes suitable operating temperature is between 5 C 40 C Disconnect the power supply when cleaning the indicator Do not immerse the indicator in water or other liquids service should be performed by authorized personnel only 3 Product Introduction 3 1 Specifications amp Features Specifications Wis moo WAS Power supply 3 D size dry batteries 4 5V 3 D size dry batteries 4 5V JWI 700D 700S 1 Features Power saving design with auto shut off function Backlit LCD display with prominent 30mm high digits Up to 1 15000 resolution Gross or net weight switchable Low battery indication Flexible unit switching Kg g lb oz JT pcs Adjustable stand for bench scale Weight accumulation max 99 pieces Manual tare pre tare simple counting check weighing and accumulation Adjustable filtering level for weighing under various conditions ouitable for a wide range of bases and load cells Adjustable capacities resolutions and parameters Enclosed PVC dustproof cover CE approved 3 2 Front Panel 3 2 1 Di
4. 1 Introduction sessssssRRRRIRRRRRRRRRR RR RII 1 DF VOC AUTON S aen ohio tec ioe cbbb be eu tede bbe a e ata bodas 1 3 Product Introduction 9 1 4p6ecilicallorns GF Call escaso vau ndbebie UD A EEATT 1 9 2 FIORI alleles ace ttre nsitrad stant taped sat Mov ais fastu tipici adele ait fonat ttai tibi totrde D S2 DISP Greene eens EE EaR 9 92 2 o UDOSI oss eestdsasimidedspsan DIE suae Rud RM UTE 4 39 9 REA T 3llelsesscescuzcatespascic Ro IhIORSUITM QD PERINI ROOPRIORSUII DIDA III RNC RISE PISN 5 oui POWST oC 0 6 a ETE 5 4 Installation Aa OAC cel Cone O sss n In PMID EU ELE ASI NE ae ME 6 4 2 Assembly Description of Upright Pole 0 ccc ccc cece ee ee eee eeeeeeeeeeanees 6 5 Setting Mode 5 1 Maximum Weighing Capacity amp Division Setting cccc cece cece cena eeees 7 Ore IF UMCHON SC UHI Oeatatannce diac omwanyen ee M g 5 3Description of Parameter ValUGS cccc cece cece cece eee eeeeee eee eeeeeneeeeeeees 9 OOAD 6 ue nnn 14 Operation PAW WN i esgoreect TT 12 OL E 7 3 Check WENNO 13 7 4 vlagei uerepino n 14 7 5 Accumulation Accumulation Display and Accumulation clear 15 S JEITOFTTESSQOO sscsacseiagoueasetenseiyon anauseesd qonasaas soe nen EOI 1 Introduction This manual contains installation and operation instructions for the JWI 700D 700S Series weighing indicator Please
5. and lower limits and the weight is equal or more than 20d out There will be a warning sound when the weight of articles is beyond the upper amp lower limit and the weight is equal or more than 20d no beep Ihree stage check weighing Buzzer in mute 10 IL Filtering setting oet the filtering level in which the stable indication turns on The higher the setting the slower stabilization time Options 1 2 3 4 Jal L 11 Tare Zero condition stable Only after the stable indication appears Tare Zero function acts after pressing down key TARE or ZERO JWI 700D 700S 10 always Tare Zero function acts by pressing down key TARE or ZERO even if it is not stable EUM 12 LI J Power saving function QM on Enable the power saving function off Disable the power saving function Press M SET then press M SAVE to start initialization After the window displays ok the initialization is finished 6 Calibration Note Before calibration please set the unit first The unit used in calibration is the one that has been set before During the calibration procedure press ZERO ESC to return to normal weighing mode without saving Here we take 3kg 10g as an example 1 Press and hold TARE while powering on Do not release it till the window displays CAL n 2 With no load on the weighing pan press TARE to start zero point calibration lt 9 V is blanking at the left bottom 3 Wait till the window displ
6. ays the first calibration value Of appears at the left bottom Note The first calibration value is default If you need to change the value do as the following Press M SET to enter the value setting Press IME or TARE to move the key leftwards or rightwards Press PRINT HI or HOL D LO to change the value Press M SAVE to Save 4 Put the corresponding weight on the weighing pan and then press TARE to complete the aL CN first point calibration As appears at the left bottom Note After the first point calibration the window can display the weight value If no need for the other point calibration move to step 6 to finish the calibration procedure 5 Add another mass to the current weight The window will show the total weight Press TARE JWI 700D 700S 11 mode 7 Operation 7 1 Weighing Begin with no load on the scale the display reading zero Place item s to be weighed on the scale The display shown is the gross weight The desired weighing unit should be selected EE nnnn ininn before weighing Co UUUU 7 7 2 Tare Manual Tare When weighing a sample that must be held in a container tare stores the container weight into memory 1 Under the weighing mode place the container on the weighing pan wait till stable symbol appears then press the key TARE The container is tared 4 To clear tare with an empty pan press down key TARE or key ZERO ESC Preset Tare 1
7. hing mode Place the sample on the weighing pan if the sample weight is under the lower weight range while over 20d the LOW lamp will light up If the sample is within the lower and upper weight range the OK lamp Will light up If the sample is over the upper weight range the HI lamp will light up 7 4 Simple Counting 1 Press key UNIT to select the unit PCS L 2 Press key G N the ex factory default sample quantity 10 pcs is displayed 3 Use key PRINT HI or HOLD LO to choose the sampling amount Available options are10 20 50 100 200 500 pieces 4 Put the corresponding samples on the weighing pan and then press key TARE UUU is displayed momentarily before the display reverts to the sample quantity gt L A d 5 Remove the samples and put the load on the scale calculates the amount of the load 6 To go back to the normal weighing mode remove the load and press key UNIT to select the proper weighing unit Note 1 The larger the sample size the more accurate unit weight 2 Symbol V points at UW when calculated unit weight is lower than 4 5 of scale division JWI 700D 700S 14 7 5 Accumulation Accumulation Display and Accumulation clear Accumulation Under the weighing mode put the item on the weighing pan Press key M SAVE at the Fr t ILILILI d appearance of Ihi adi is displayed momentarily before the display reverts to the weight of the item Remove the item a
8. nd the display goes back to zero before the next accumulation can register The maximum is 99 pieces display the latest 10 accumulation events in details Accumulation Display Press key MR to display the accumulation data MR a or TAHE to check the total accumulation and each accumulation event in detail The number of weighments is indicated by Auxiliary display at the left bottom t XX Total accumulation XX certain accumulation Accumulation Clear To clear accumulation data total accumulation data or one of the accumulation events press key M SET while the data is displayed To exit and return to normal weighing mode press key ZERO ESC 8 Error message ERRO Exceed the zero range ERRI Model setting error Resolution should be within 300 300000 ERR2 Exceed the initial zero point o ERR3 Exceed the A D resolution range S ERR4 EEPROM failure o ERR5 Overload condition ERR6 Exceeds the display range 0 000 ERR9 Exceed tare or pre tare range o ERR10 Wrong calibration weights S O JWI 700D 700S 15
9. or TARE to shift key leftward or rightward Press PRINT HI or HOLD LO to change the value Press M SAVE to save and return 6 Press ZERO ESC to return to normal weighing mode 5 2 Function Setting 1 Press and hold M SET while powering on or long press M SET under normal weighing mode to enter function setting The window displays check Setting item P00 displays momentarily at the left bottom Press MR or TARE to shift between the functions Press M SET to enter the function parameter setting Press IMR lt or TARE to shift between the function parameters Press M SAVE to save and return to higher option Press ZERO ESC to return to higher option without saving Press ZERO ESC to return to normal weighing mode JWI 700D 700S 8 5 3Description of Parameter Values HOLD 3 HOLD Offset value the offset value and the keypad testing can be conducted J o o Q lt UN t Backlight mode Off No backlight Auto Auto on with items greater than 9d placed on the weighing pan or any key is pressed But auto off after N seconds N 2s 5s 10s 20s ever with no action Ever It is always on when the weights over 9e On Backlight on Hi 3 IILIL Auto off Off Non power off 5 10 gt 30 gt 60 minutes M 4 LIN IL Unit setting E onoFF select the unit pcs gt JT lboz gt g gt kg on Enable the unit off Disable the unit Note Pre
10. s smaller than lower limit but over 20e with LOW lamp on b 4d Stable indication 3 2 2 Keyboard JWI 700D JWI 700S 0 BD Y 3 Ge GB CD CD GD ev KD ee Short press steps through activated weighing units release on desired one DMD 2 c pe x SN D Displays gross and net weight by turns When under simple counting mode long press to enter sample quantity choose Adds the indicated weight into accumulation memory During editing returns to the higher option save the settings Zeros the display within 296 of max capacity Exits from certain operation without save Enter parameter setting Enable Disable check weighing function Deletes accumulation records Tares the weight of the container or accepts the keypad tare entries Shift keys rightwards when inputting the value JWI 700D 700S 4 Memory recall NO Shift keys leftwards when inputting the value Select the former record when checking the accumulation record Print out when connect to the printer During setting value add 1 to the current value oet the upper limit of the check weighing Select the later record when checking the accumulation record Hold the weighing value During setting value deduct 1 to the current value Set the lower limit of the check weighing Rwonw a R OD gt 3 3Rear Panel 1 Port for connecting load cell 2 Adaptor socket 3 Power ON OFF switch 3 4 Power supply JWI
11. splay JWI 700D KAN Ne pes meg m o IR tli p s kg wu M HI LO STABLE O O O HI OK LOW JWI 700D JWI 700D 700S 2 JWI 700S J a FunO CHARGE H 0O y PCS ary oK O em Wi Low O nin kg mal TARE PRESET NET UW M HI LO STABLE 1 4 i a Low battery indication v J Tare or Preset Tare Indication 0 Center of Zero Indication The zeroing range is 2 of scale capacity LLL Auxiliary display battery power parameter accumulated number of weighments TARE Symbol V points at TARE when the weight of the container is tared PRESET TARE Symbol V points at Preset Tare when Tare value entered via keypad NET Net weight Gross weight minus Tare Symbol V points at NET when Tare or Preset Tare action are done ay UW Symbol V points at UW when calculated unit weight is lower than 4 5 of scale division Unit weight is too small for ensuring accurate quantity calculations M Symbol V points at M when there is accumulation data HI LO Symbol V points at HI LO when check weighing function is on FULL Charging finish CHARGE Charging Pcs uU Fr PA I Db o K Units of measure The weight on the weighing pan is greater than the upper limit with HI lamp on The weight on the weighing pan is between upper and lower limits with OK lamp on JWI 700D 700S 3 The weight on the weighing pan i
12. ss UNIT to choose the weighing unit Press ME or TARE to enable disable the unit 5 FET Il Zero range dO d1 d2 d3 d4 and d5 d scale division JWI 700D 700S 9 IPTE 6 HUL LI Hold function HoLd 0 No hold function HoLd 1 Hold the peak weighing value Press any key to release HoLd 2 Hold the weighing value after stable Press any key to release HoLd 3 Hold the weighing value after stable Move away the articles to release HoLd 4 Hold the weighing value while pressing down key HOL D LO Press any key to release Note the weight should be over 20d 7 LIU Check weighing memory on Check weighing function when restart the indicator is the same with that before powering off off Check weighing function would not auto on when restart the indicator reer 8 LILIL Stable Check Weighing On Check weighing after stable indicator appears and the weights is between the upper and lower limit Off Check weighing when the weights is between the upper and lower limit EI LL Check Weighing buzzer beep a CO a et ee Hi There will be a warning sound when the weight of articles exceeds the upper limit and the weight is equal or more than 20d LO There will be a warning sound when the weight of articles exceeds the lower limit and the weight is equal or more than 20 d ok There will be a warning sound when the weight of articles is between the upper and lower limit including the upper
13. tion is completed Note Use the knob pole 7 to adjust the inclination angle of indicator and the screw 6 to adjust direction of the indicator After adjusting the indicator to an optimal position lock the screw 5 Setting Mode 5 1 Maximum Weighing Capacity amp Division Setting 1 Press and hold key UNIT and M SET while powering on the scale When the window displays CAP release the key and it enters the capacity amp division setting 2 Press MR lt or TARE to shift among CAP capacity setting DIV division setting accura resolution check 3 When the window is showing CAP press IM SET to enter capacity setting Method1 Press MR a or TARE to choose the general used capacity Press M SAVE to save and return JWI 700D 700S 7 Method2 Press M SET to free set the resolution Press UNIT to choose the weighing unit Press MR lt or TAHE to shift key leftward or rightward Press PRINT HI or HOLD LO to change the value When move to the right most press PRINT HI or HOL D LO to move the decimal point Press M SAVE to save and return When the window is showing DIV press M SET to check the division Press ZERO ESC to return When the window is showing accura press IM SET to enter resolution setting Methodi Press MH or TARE to choose the general used resolution Press M SAVE to save and return Method 2 Press M SET to free set the resolution Press MR 4
Download Pdf Manuals
Related Search
Related Contents
RTPCR User Guide - Gene Providence Home Services CPAP/BiPAP Mode d`emploi d`un Groupement d`Employeurs Philips 535 Cell Phone User Manual ETESIAN MINI GUIDE RAPIDE Black & Decker T100 Series Use & Care Manual Biostar I945P-M7 Owner's Manual ソフトウェア使用規約 Copyright © All rights reserved.
Failed to retrieve file