1. cells on scaffolds or primary tissue explants establish a uniform very low shear fluid suspension orbit within the horizontally rotating culture vessels As the cells proliferate the rotation speed is adjusted to compensate for increased sedimentation rates The absence of damaging stress forces allows three dimension aggregation of large cell masses Normal neoplastic mono and co cultures of fragile human anchorage dependent and suspension cells have been grown in vitro One of the primary advantages of the new Rotary Cell Culture System over conventional systems is its ability to grow tissue cultures that differentiate or mimic the structure and function of the parent tissue The investigator can inoculate the culture with the same mixture of cells which normally occurs in vivo These cells grow and organize into three dimensional tissue aggregates similar to the parent tissue Such growth is possible because destructive turbulence and collision forces are minimal within the horizontal Rotary Cell Culture System Surgical explants or biopsies can be transferred into the RCCS and be maintained without necrosis This extremely low shear culture environment can be used to grow virtually any cell type that can be cultured in conventional culture systems see the bibliography at www synthecon com for examples The SYNTHECON Inc Rotary Cell Culture System RCCS enables a scientist with a standard tissue culture laboratory to produce very com
2. equivalent overnight 7 Air dry the vessel parts 8 Assemble vessel 9 Sterilize as described below Sterilization Autoclave Method 1 Remove fill port cap and autoclave separately from vessel 2 Place plastic caps or aluminum foil on syringe ports to protect from contamination during reassembly 3 Loosen center bolt 1 turn with Allen wrench tool supplied 4 Place vessel and cap in autoclave bag or wrap with foil and autoclave for 20 minutes at 121 C 5 Remove from autoclave and allow to cool Experimental Start up 1 Transfer the vessel to a laminar flow hood Place the fill port plug on a sterile alcohol swab 2 Attach sterile valves to the syringe ports 3 Fill the vessel partially with media leaving enough space to add cells and scaffolds or microcarriers 4 Add scaffolds or microcarriers via the fill port 5 Add cells If desired cells and microcarriers can be mixed and added together 6 Fill the remaining volume of the vessel with media and insert the fill port plug There will always be small bubble remaining after this step It is necessary to remove this bubble before starting the culture in order to minimize turbulence 7 Bubble removal Fill a 3 or 5 ml sterile syringe with media and attach to one of the valves on a syringe port Attach a 3 or 5 ml sterile syringe on the valve of the other port Open both valves Maneuver the bubble under the empty syringe port and inject media from the filled syringe R
3. 55 ml only C Syringe Ports D Front Plate E Back Plate With a few exceptions noted below the procedures for the High Aspect Ratio Vessel are the same as with the Slow Turning Lateral Vessel 1 The smaller vessels do not have a fill port Consequently filling of these vessels must be done through the syringe ports This also limits the size of the scaffolds to those that can be introduced through the syringe ports 2 The High Aspect Ratio Vessel is held together with small screws around the periphery of the Front plate Each of these screws should be loosened during autoclaving and then tightened before adding media Do not overtighten these screws 10 2 When changing media the vessel should be placed vertically in the hood with the fill port at the top and secured to prevent it from rolling The cell aggregates or scaffolds are allowed to settle at the opposite end of the vessel from the fill port The vessel should then be propped at a shallow angle to keep the aggregates or scaffolds at one end and the fill port opened A pasteur pipet connected to a vacuum source is then introduced through the open fill port and as much media as possible removed without disturbing the concentrated aggregates or scaffolds at the other end of the vessel Fresh media is then added the fill port plug replaced and the bubbles removed as described with the Slow Turing Lateral Vessel Equipment Usage Rights SYNTHECON Inc grants the purch
4. January 29 1991 e Patent number 5 026 650 HORIZONTALLY ROTATED CELL CULTURE SYSTEM WITH A COAXIAL TUBULAR OXYGENATOR Patent issued June 25 1991 e Patent number 5 153 131 HIGH ASPECT RATIO VESSEL AND METHOD OF USE Patent issued October 6 1992 e Patent number 5 155 035 METHOD FOR CULTURING MAMMALIAN CELLS IN A PERFUSED BIOREACTOR Patent issued October 13 1992 e Patent number 5 153 133 METHOD FOR CULTURING MAMMALIAN CELLS IN A HORIZONTALLY ROTATED BIOREACTOR Patent issued October 6 1992 e Patent number 5 998 202 MULTIPLE CHAMBER DIFFUSION VESSEL Patent issued December 7 1999 e Patent number 5 989 913 CULTURE VESSEL FOR GROWING OR CULTURING CELLS CELLULAR AGGREGATES TISSUES AND ORGANOIDS AND METHODS FOR USING THE SAME Patent issued November 23 1999 11 Alterations Alteration of the eguipment voids the warranty on this eguipment In no case shall SYNTHECONTM Inc be responsible for any modifications or alterations to this eguipment performed by anyone other than SYNTHECON Inc IMPORTANT NOTICE Limited Warranty Limited Liability SYNTHECONT Inc warrants that for one year under normal operating conditions and use this equipment will be free from defects of materials and workmanship SYNTHECONTM Inc will repair or replace defective parts at our option Contact SYNTHECONTM Inc immediately upon discovery of a defect SY NTHECON will provide you with a return authorization number
5. Synthecon Customer Service Dept 8044 El Rio Houston TX 77054 Please include a short description of the problem service required or reason for the return Please pack equipment being returned in sturdy containers with adequate packing materials Synthecon will not be liable for damage sustained during shipment SYNTHECON Inc also provides biology and engineering contract support services Special custom designed equipment can be built to meet the customer s needs Customers can provide cell samples of their cell and tissue lines and SYNTHECON Inc will conduct growth and feasibility studies of the customer s cells on a contract fee basis Sub licenses are available which would include design scaleup and manufacture of production equipment 12 Copying and Sale Duplication modification or sale of copies of this eguipment is prohibited This eguipment is patented by the U S Government SYNTHECON Inc holds the exclusive licenses to these patents Acceptance of Equipment The purchaser shall inspect the equipment delivered and immediately notify the seller of any discrepancies with the equipment If the purchaser fails to provide notice in writing within 14 days after the delivery of the equipment the purchaser will be presumed to have accepted the equipment The acceptance and use of this equipment constitutes an agreement upon the purchaser s part to the usable condition of the equipment Refurbished Products Refu
6. and shipping instructions Components Oxygenator Membrane The oxygenator membrane is a very delicate component consisting of silicone rubber 005 inches thick covering a polyester cloth backing Care and attention should be given to the membrane during cleaning sterilization and removal of cultured material Synthecon reserves the right to make discretionary determination as to the cause of damage with returned oxygenators and deem whether the repair is covered under the Synthecon Limited Warranty See Operators Manual for appropriate procedures Rotator Base Storage of the Rotator Base in an incubator while not in use will result in damage to the rotator components Synthecon reserves the right to make a discretionary determination as to the cause of damage with returned rotators and deem whether the repair is covered under the Synthecon Limited Warranty The equipment must be used and operated in a careful and proper manner In no event shall SYNTHECON Inc or its suppliers be liable for any indirect special or consequential damages including but not limited to loss of cells medium data labor or equipment incurred by the purchaser or any third party arising from the use of or inability to use this equipment Service For service during and after the expiration of the warranty contact SYNTHECONTM Inc at 713 741 2582 during 9 a m to 5 p m US Central Time Zone Equipment being returned for service should be shipped to
7. aser a non exclusive right to use the Rotary Cell Culture System equipment solely for the purpose of conducting research and specifically excluding use of this equipment for any purpose other than research Synthecon technology is not intended for use on in humans Any desire by end user to manufacture commercial products in Synthecon Inc technology will require the end user to obtain a User s License from the National Aeronautics and Space Administration and or Synthecon Inc Its use must comply with all laws ordinances and regulations relating to the possession use or maintenance of the equipment including registration and or licensing requirements if any Patents in Force The Rotary Cell Culture System is protected by patents exclusively licensed from the National Aeronautics and Space Administration NASA and patents owned by Synthecon Inc with others pending The patents Synthecon Incorporated operates under are listed below e Patent number 5 437 998 GAS PERMEABLE BIOREACTOR AND METHOD OF USE Patent issued August 1 1995 e Patent number 5 665 594 GAS PERMEABLE BIOREACTOR AND METHOD OF USE Patent issued September 9 1997 e Patent number 5 702 941 GAS PERMEABLE BIOREACTOR AND METHOD OF USE Patent issued December 30 1997 e Patent number 5 763 279 GAS PERMEABLE BIOREACTOR AND METHOD OF USE Patent issued June 9 1998 e Patent number 4 988 623 ROTATING BIO REACTOR CELL CULTURE APPARATUS Patent issued
8. epeat this procedure until all bubbles are removed from the vessel Close both valves and replace caps 8 Attach the vessel to the rotator base 9 Place the rotator base with vessel in a humidified CO incubator Attach the power cable to the back of the rotator base and to the power supply 10 Turn the power on and adjust the rotational speed If using scaffolds which are visible to the naked eye the speed should be adjusted so that the scaffolds are maintained in suspension without touching the vessel walls If suspended cells or microcarriers are being used the inital speed can be set at approximately 10 rpm Anchorage dependent cells will form aggregates and the rotational speed may have to be increased to compensate for the increased sedimentation rate as the aggregates increase in size Medium Replacement 1 Turn off the power remove the vessel from its base and take it to a laminar flow hood 2 Stand the vessel vertically with the valves facing up and allow the scaffolds beads or cell aggregates to settle to the bottom 3 Remove the fill port plug and place it on an alcohol swab 4 Aspirate approximately 3 4 of the media being careful not to remove any cells 5 Fill the vessel with fresh media and remove bubbles as described above and return the vessel to the rotator base in the incubator Resume the rotation High Aspect Ratio Vessel Procedures High Aspect Ratio Vessels A Peripheral Screws B 1 2 Fill Port
9. in the RCCS Developed at the Johnson Space Center the system was originally designed to protect delicate tissue cultures during spaceflight However it quickly became apparent that the unique environment of low shear force high mass transfer and simulated microgravity provided by the system enables 3D cell growth to take place in a conventional laboratory tissue culture incubator Two basic types of RCCS vessels are manufactured by SYNTHECON Inc The Slow Turning Lateral Vessel STLV is tubular shaped and has a central gas transfer core and is designed for use primarily with anchorage dependent cells The High Aspect Ratio Vessel HARV has a disc shaped culture chamber with the oxygenator membrane forming the inside wall of the vessel The HARV was designed for use with suspension cells However experience has shown it to be an excellent culture vessel for anchorage dependent cells and tissue explants as well Principles of Operation Tissue Culture in the Rotating Cell Culture Vessel The Rotary Cell Culture System is a horizontally rotated bubble free culture vessel with membrane diffusion gas exchange The culture medium cells and cell aggregate particles rotate with the vessel and do not collide with the vessel walls or any other damaging objects when rotated at appropriate speed Destructive shear forces are minimized because this system has no impellers airlifts bubbles or agitators Suspension cells anchorage dependent
10. manufacturer s instructions The cells and microcarriers can be mized and pipetted into the vessels together Cells will readily attach to the microcarriers while the vessel is rotating It is not necessary to stop the vessel rotation during the attachment phase Attachment of cells to the microcarriers is normally complete within 24 hours Vessel Preparation Note Do not soak any part of the vessel in bleach acidic or basic cleaning solution Vessels will absorb such solution rendering them toxic to cells Abrasive cleaners or strong organic solvents such as acetone will destroy the plastic voiding the warranty 1 Using the Allen wrench supplied unscrew and remove the center bolt A on the front end cap F Remove the end cap and the vessel wall Unscrew the bolt on the rear end cap and separate the oxygenator core D from the rear end cap taking care not to damage the membrane on the core Remove o rings from both end caps 2 Place all vessel parts in a large beaker or other container filled with laboratory detergent Allow the parts to soak for at least 1 hour 3 Scrub plastic parts except oxygenator core with a soft brush to remove any residues 4 Gently clean the oxygenator core with the tip of the finger using latex laboratory gloves Note Harsh scrubbing will damage membrane material Do not use a brush to clean the membrane 5 Thoroughly rinse vessel parts with tap water 6 Soak vessel parts in ultra pure water Milli Q or
11. n Kang Rd Taipei Taiwan R O C Tel 02 785 1156 Fax 02 788 5896 thlsl ms9 hinet net Japan Tomy Digital Biology Co Ltd Edge Building 2 9 1 Ikenohata Taito ku Tokyo 110 008 Tel 81 3 5834 0810 Fax 81 3 5834 1888 E mail info digital biology co jp Web www digital biology co jp India Medi Analytika India Pvt Ltd 1 floor Adyar Bridge Road Adyar Madras 600 020 India Tel 9 1 44 2446 0988 2446 3084 2446 3085 Fax 9 1 44 2446 3931 mediana vsnl com
12. of the Slow Turning Lateral Vessel STLV should be backed off one turn before autoclaving The peripheral screws on the High Aspect Ratio Vessel HARV should be released one turn before autoclaving After autoclaving be sure to tighten the screws which have been loosened Since media formulations vary with each application no recommendations are made as to which medias will work best with a particular cell type In general medias which work well in other culture systems will work well in the RCCS The humidification of the incubator in which the RCCS is placed must be maintained Even though the RCCS is a closed culture system evaportation of fluid can occur through the oxygenator membrane This is particularly important with the 10 ml HARV Bubbles cause turbulence which can damage cells Any small bubbles which form during the culture should be removed as soon as they are observed Cells will readily attach to microcarriers or other scaffolds while the vessel is rotating It is not necessary to pre attach cells to scaffolds in static culture Slow Turning Lateral Vessel Procedures Slow Turning Lateral Vessel STLV Center Bolt 1 2 Fill Port Plug Syringe Ports Oxygenator Membrane and Core Vessel Wall Front End Cap Rear End Cap A B C D E F G Microcarrier Preparation If using microcarrier beads with anchorage dependent cells prepare the microcarriers in accordance with the
13. plex differentiated tissue like constructs As a bonus users who need to continuously monitor their cell cultures can easily take samples at very short intervals without damaging the culture The effects of changes to a cell culture caused by the addition of other cell types chemotherapeutic agents nutrients chemicals or consumer test products can be easily observed Harvesting the culture is simply a matter of removing the end cap and pouring out the culture or aspirating it with a pipette No release agents or scrapers are required Notes and Cautions Please read before using Please complete and return the Limited Warranty Sheet on page immediately The Warranty will not be valid unless it is signed and returned to Synthecon Do not soak any part of the vessel in bleach acidic or basic cleaning solutions The plastic and rubber in the vessels can be impregnated with toxic chemicals from such solutions rendering them toxic to cells As an example chlorine bleach will permanently poison the vessel Corrosive chemicals such as chromates will damage metal parts Abrasive cleaners or strong organic solvents such as acetone will destroy the plastic and void the warranty The oxygenation membrane is particularly susceptible to damage The oxygenator membrane is a very delicate component composed of silicone rubber 0 005 inches thick covering the polyester cloth backing When inserting pipets or any type of instrument into the vessel
14. rbished products carry a separate warranty this warranty does not apply For details of refurbished product warranty please refer to the refurbished product warranty information packaged with each refurbished product WARRANTY WILL NOT BE VALID IF IT IS NOT SIGNED AND RETURNED Warranty valid to original purchasers only Please sign and return by mail immediately to For international locations see the very last page Synthecon Inc Customer Service Department 8044 El Rio Houston TX 77054 Purchaser Institution Organization Purchase Date Invoice PO Model Serial Number s PLEASE NOTE THAT THIS PAGE IS FOR YOUR RECORDS PLEASE USE THE YELLOW PAGE THAT ACCOMPANIES THIS MAUAL FOR WARRANTY REGISTRATION 13 14 International Locations USA SYNTHECON INC 8044 El Rio Houston TK 77054 Tel 713 741 2582 Fax 713 741 2588 rccs synthecon com Europe Cellon 29 Am Bechler L 7213 Bereldange Luxembourg Tel 352 26 33 73 1 Fax 352 311 052 www cellon lu e mail cellon gms lu China PRC East Lake Cell Co 369 Guangshan Rd East Lake Hi tech Zone Wuhan Hubei China Tel 86 13986239916 86 27 87052473 www eastlakecell com Equl Corp Rm 1205 10 Bldg 168 HongQiao Rd Shanghai 200030 P R CHINA Tel 021 22817530 51096009 Fax 021 23010002 e mail info equl com Website http www equl com Taiwan Tseng Hsiang Life Sciences LTD No 99 15 Sec 2 Na
15. thecon INCORPORATED The Rotary Cell Culture System RCCS I RCCS 4 The Premier Tissue Engineering Culture System Synthecon Incorporated 8044 El Rio Houston Texas 77054 www synthecon com recs synthecon com 713 741 2582 800 853 0740 User s Guide Table of Contents Introduction Principles of Operation Notes and Cautions s0e Slow Turning Lateral Vessel Procedures ss0 e High Aspect Ratio Vessel Procedures Introduction The Rotary Cell Culture SystemTM RCCS is new technology for growing either anchorage dependent or suspension cells in the laboratory The system enables the researcher to cultivate many types of cells to high densities Cells that could not be grown easily by other methods have been grown without difficulty in RCCS vessels The growth of co cultures of differentiated 3D aggregates that mimic the structure and function of the parent tissues can be achieved in the RCCS The system provides a reproducible complex 3D in vitro culture system for the investigation of the structural processes and regulatory molecules that control differentiation in normal tissues and transformation in neoplastic tissues Some articles in scientific journals have used the term organoids to describe the 3 dimensional differentiated tissue models and expanded surgical explants that have been grown
16. while culturing cells avoid touching the membrane Even the smallest breach of the membrane will render the vessel unusable and require that the vessel be returned to Synthecon for repair During cleaning use latex gloves and gently clean the membrane with the fingertip With proper handling the membrane should last for many culture cycles before requiring replacement Storage of the Rotator Base in an incubator when not in use will result in damage to the motor and will void the warranty The ribbon power cable passes easily between the incubator door and gasket without compromising the incubator environment The power supply can be conveniently located on top of or beside the incubator The power supply must never be operated inside of the incubator Subjecting the vessel to a strong vacuum by forcefully pulling back on syringes attached to the ports could burst the oxygenator membrane and require replacement of the membrane Do not over tighten bolts and fittings Excessive force will strip the threads on the plastic components An autoclave cycle of 121 C for 30 minutes is recommended Exceeding this temperature will accelerate degredation of plastic components Residues in dirty autoclaves may inpregnate the oxygenator membrane and plastic parts and cause the vessel to become toxic The vessel should be autoclaved as an assembled unit This reduces the risk of contamination during assembly The central core assembly screw