User guide for lux meter TM213 - Measuring instruments in Malaysia

image

Contents

1. UV sterilization Virology Microbial genetics DNA research Biologic hoods General laboratory use 5 NAME AND FUNCTION OF EACH PART 5 1 THE LCD DISPLAY SHOWS 1 Main display 2 Reading lock ow ZEROEZ _ 3 ZERO display 4 Low power reminder 5 uW cm unit display Wem mem 6 mW cm unit display 7 Decimal point display 5 2 BUTTONS 1 The power switch button ec 2 Backlight button 3 hold lock button 4 zero button 5 UNIT buttons 2 TENMARS TM 213 6 ELECTRIC SPECIFICATION SPECIFICATIONS DISPLAY 3 3 4 digits LCD with maximum reading 4000 Range uW cm gt mW cm Ranges and range 3999 uW cm 39 99mW cm 1000 uW cm 1 mW cm UV sensor spectrums Band pass 290 nm to 390 nm Accuracy 4 2491 FS full scale 15 other visible light source Peak sensitivity wavelength 365 nm Sample Time Approx 3 sec Accuracy lt 3 year Over input Display shows OL Operating Temperature 5 40 below 80 RH Storage temp amp RH 10 C 60 C below 70 RH Battery life Approx 50 hr Size Main instrument 133 x 48 x 27 mm approx 90g EMC this instrument is EMC compliant and has undergone compatibility tests according to EN61326 1997 A1 1998 2 2001 ACCESSORIES User manual 2 batteries 1 5V AAA 2400 Carrying case TENMARS 7 TEST PROCEDURE 7
2. 1 POWER BUTTON TM 213 Press button to turn ON power The display comes alive 1 e Press button once again to turn OFF power and put the device go into sleep mode The display changes from light to dark 7 2 ZERO BUTTON Press the button for the zero adjustment if any digits are appearing e f performing the zero adjustment after powering on several digits may not disappear In this case perform the zero adjustment again TENMARS TM 213 7 3 BACKLIGHT DISPLAY AND READING IN THE DARK Press B key backlight light on Again press button to power off e Backlight light turns off automatically after 30 seconds 7 4 UNIT BUTTON e Press button to turn ON the power and put the device to operating mode The screen displays 0000uW cm Press the 2 button to switch from 0000uW cm to 00 00mW cm To select a different unit just press this button once again 7 5 DATA HOLD BUTTON HOLD Press the button to go into hold mode and appears the screen to allow to read the data Press this button once again to deactivate it TENMARS TM 213 TENMARS TM 213 8 SAFETY AND MAINTENANCE e Observing the proper polarity re screw the battery cover and reposition the protective holster e Operating altitude below 2 000m e Operating environment for indoor and outdoor use expos
3. Repairs made necessary by improper use including adaptation to particular applications not foreseen in the instructions manual or improper combination with replacement Before replacing batteries disconnect the Turn OFF the meter and disconnect the test leads from the input terminals Use of hand or screwdriver Unscrew the battery cover and remove the battery Insert a new battery of the same type 2 batteries 1 5V AAA MN2400 LRO3 AM4 6 7 TENMARS TM 213 incompatible accessories or equipment Repairs made necessary by improper shipping material causing damages in transit e Repairs made necessary by previous attempts for repair carried out by non skilled or unauthorized personnel e Instruments for whatever reason modified by the customer himself without explicit authorization of our Technical Dept The contents of this manual may not be reproduced in any form whatsoever without the manufacturer s authorization Our products are patented and our logotypes registered We reserve the right to modify specifications and prices in view of technological improvements or developments which might be necessary Service If the equipment is an exception calling repair before you test the battery and test lines and other conditions if necessary replace it If the device still does not operate check whether the operating procedures described in this manual consistent To equipment repai
4. TENMARS UV AB Meter TM 213 User s Manual 4 HB2TM2130002 TENMARS ELECTRONICS CO LTD CONTENTS 2 m 2 O 2 n U m Q a gt Q n 79 m Q 21 O gt 2 n 5 m 2 lt O m m 2 H TENMARS 1 TM 213 FOREWORD Thank you for purchasing our product Please read the operating instructions in details before you use this UVAB optics meter so you will operate the meter correctly This meter can be used in industry and home FEATURES Professional high quality UV meter Ultra violet irradiation measurement of UV UV detector spec trim from 290 nm to 390 nm Measurement range 3999 uW cm 39 99 W cm Build Zero button Microprocessor circuit provides high reliability and durability Separate UV LIGHT probe allows user to measure the UV light at an optimum position LCD display easy readout Overload display OL Power off Manual on off by push button or auto shut off after 15 minutes Measurement There 1yw cm 1 00mW cm APPLICATIONS INDUSTRIAL Monitoring blue light radiation hazards in welding UV sterilization Graphic arts Photochemical matching UV EPROM erasure Photos resist exposure Curing of inks adhesives and coatings Convenient no need to adjust data displayed clearly TENMARS TM 213 4 LABORATORY Weathering degradation studies
5. e to pollution level Il 27 This is a precision device During use storage do not 1 go beyond its spec to prevent any possible damage or gt danger gt Do not put this device direct sunlight or where it is hot and or damp sah Remember to turn OFF the power after use For long _ storage remove the battery to prevent the battery from leaking to cause damage to the parts inside Clean the device with a dry soft cloth Wet cloths liquid 10 SERVICE d wat hibited Senge ee Warranty Conditions This instrument is guaranteed for one year against 9 BATTERY REPLACEMENT material or production defects in accordance with our ot general sales conditions During the warranty period the When the symbol is displayed batteries need manufacturer reserves the right to decide either to repair or replace the product Should you need for any reason to return back the instrument for repair or replacement take prior agreements with the local distributor from whom you bought it Do not forget to enclose a report describing the reasons for returning detected fault Use only original test leads from any energized circuits to packaging Any damage occurred in transit due to non avoid electrical shocks original packaging will be charged anyhow to the customer The warranty doesn t apply to Accessories and batteries not covered by warranty e
6. r you must return the service at the local address or regional offices the customer pays the freight must be obtained before sending the other party s consent Must be used to send the original packaging and included in the device more clearly as possible the content If you do not use the original packaging to send the sender will be responsible for damage caused Shouldn t the instrument work properly before contacting your distributor make sure that batteries are correctly 8 TENMARS TM 213 installed and working check replace them if necessary Should you need for any reason to return back the instrument for repair or replacement take prior agreements with the local distributor from whom you bought it Do not forget to enclose a report describing the reasons for returning detected fault Use only original packaging Any damage occurred in transit due to non original packaging will be charged anyhow to the customer The manufacturer will not be responsible for any damage to persons or things 11 END OF LIFE Caution this symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal