1. a Disconnect all Weigh Bars b Try to zero the indicator by pressing GROSS and ZERO CLEAR lf you are unable to zero the indicator with the Weigh Bars disconnected the problem is in the indicator and you should contact your supplier O Ifyou are able to zero your indicator with the Weigh Bars disconnected then the problem is probably in the cabling or the Weigh Bars and you should continue troubleshooting 3 Reconnect all Weigh Bars You will see Error displayed again 4 If your Weigh Bar connectors have the four pin configuration disconnect one Weigh Bar and connect an adapter plug in its place If your Weigh Bar connectors have the five pin configuration disconnect one Weigh Bar No adapter plug is necessary 5 Try to zero the indicator Repeat Steps 4 and 5 with each Weigh Bar cable making sure each time that all cables are connected except the one you removed for five pin connector or replaced with an adapter plug for four pin connector A defective Weigh Bar may be easily recognized with this method when a defective bar is replaced with an adapter plug for four pin connector or removed for five pin connector the indicator will zero properly 7 4 Inaccurate Weight Readings First Visually inspect the scale system for apparent problems and improper installation 1 Check each cable from source to indicator for stress cuts breaks or abrasions 2 Unplug and reconnect each connector at the indica
2. examples shown below Model 915A See Appendix A ID will only be printed if an ID is entered MODEL 2154 Ib 12345678 G1 694 8682 788 0693 698 0604 D 915 0006 624 DD 797 DD 679 DD 845 Gola 914 Layout 2 9010 12345678 Layout 3 MODEL 915A ID 12345678 02 83 13 10 12 02 COUNT aula TOTAL 7716 lb AVERAGE 7ri lb HIGH 915 lb LOW 624 1b Layout 4 Figure 6 1 Print Layouts Follow these steps to remove all the statistics from memory 1 From gross mode repeatedly press MENU until Cir StAt is displayed Press SELECT yes or no is displayed 1619 1b Layout 45 Use the MENU key to toggle between the choices Press SELECT when the choice you want is displayed Stats are cleared or not depending on your choice Press the G N key to return to gross weighing mode Model 915A Indicator User Manual 6 6 Setting Auto LOC Follow these steps to turn Auto LOC on or off Te From gross mode repeatedly press MENU until Auto LOC is displayed 2 Press SELECT ON or OFF is displayed 3 Press MENU to toggle between the choices Press SELECT when the choice you want is displayed Auto LOC is displayed 4 Press the G N key to return to gross weighing mode 6 7 Viewing and Setting the Time 1 From gross mode repeatedly press MENU until Hour is displayed 2 Press SELECT The time will be displayed in hours minutes and seconds 3 Enter the correct time allowing spaces for h
3. or the RD912 Figure 8 2 Radio Remote 22 Model 915A Indicator User Manual 9 User s Menu nuau ay ul a SOU 0 Aen 193738 24 SSA nua ay Ul lt 019S 0 Le NNJIN 9U SS Jd 159 doo ou Key lt 7 PO 10d007 ue ssaig gare 14517 UBIH wa ofeaua 18101 a junog NNIN Seid i f i i SIA ON j Kejay euas e suopng a fejdsig AA NN dA A asn sY JO A ANAW ssd paunbyuoo spun 40 NO AA WW da E A 10 ISINOY o XXXXX abej oA yndu XA GO NN ES WW HH A i i t Y yos leg sa upg 4 a a noy le 207 0Y e es JI Ee d Seng ANA Ploy pue ssald 23 Model 915A Indicator User Manual 10 Appendix A Customizing Printouts 10 1 Layout 1 5 89 ZI The hidden E key is between the 9 and the M keys on the indicator Below are the steps to choosing Layout 1 5 1 Key in 915 915 is displayed 2 Press hidden E key and hold for two seconds 915 E is displayed 3 Press SELECT ConF is displayed 4 Press MENU repeatedly until SEriAl is displayed di Press SELECT bAUd is displayed 6 Press MENU repeatedly until LAYoUt is displayed 7 Press SELECT 1 5 is displayed 8 Press MENU until the layout you want is displayed then press S
4. power still on plug in cables one at a time Weigh Bar cables first then alarm cable then printer remote display cable until plugging in one of the cables causes the indicator to shut off That cable is the bad one and needs to be repaired or replaced 7 2 Stalled Display Following Power On This category of problems can exhibit any one of the following symptoms e An illegible display that cannot be zeroed and from which you cannot exit e A legible display such as HELLO that cannot be zeroed and from which you cannot exit Anilluminated backlight with no characters displayed and allowing no exit e lf the red illumination on the display is visible telling you the indicator has power on a sunny day you may have to shade the display you can possibly restore the display function by doing a reinitialization explained below To Reinitialize a Stalled Indicator 1 Press OFF 2 Press ZERO CLEAR and hold in while you 3 Press and release ON 4 Then release ZERO CLEAR If the display says HI instead of HELLO following a reinitialization power on your indicator has a potential problem and should be checked Contact your supplier Model 915A Indicator User Manual 17 7 3 Indicator Lock Up A locked up indicator is represented by an illuminated alarm light and a display of Error 1 Shut off the alarm by pressing any key 2 Test the Weigh Bar cables to isolate the source of the lock up problem as follows
5. the controls accessible Positioning the quick detach bracket with the wider end at the top mark the desired mounting location If bolting use the quick detach bracket as a template and mark and drill holes Weld or bolt the quick detach bracket at the appropriate location If bolting use double nuts or self locking nuts to protect both indicator and machinery Insert the indicator bracket into the quick detach bracket and push it down into place For mobile applications wrap and twist a strong wire around the indicator bracket and the quick detach bracket to stabilize the mounting Model 915A Indicator User Manual 21 8 2 RD 912 Remote Display The RD912 is a remote display that is compatible with the Model 915A An RD912 output option is required on the Model 915A for interfacing The interface cable plugs directly into the bottom of the Model 915A refer back to Figure 5 1 When using the remote display any data displayed on the Model 915A is also displayed on the RD912 o Avery Weigh Tronix MOTION Avery Weigh Tronix di I Figure 8 1 Model 912 Remote Display 8 3 Optional Radio Remote Transmitters XM710 L and XM910 and Receiver An optional radio remote transmitter and receiver can be installed This option lets the user configure the XM710 to act as a ZERO PRINT M M RM TARE or G N key and work at up to 100 feet away It can be installed in either the Model 915A
6. 5A Indicator User Manual 25 10 Press G N key to exit programming mode and return to the gross weighing mode 10 2 1 To Delete All ASCII Characters 1 Access Serial ASCII in the configuration menu ASCII is displayed 2 Press the ZERO CLEAR key ASCII blinks and all the control codes are cleared 10 3 Enabling Auto Print 1 Key in 915 915 is displayed 2 Press hidden E key and hold for two seconds 915 E is displayed 3 Press SELECT ConF is displayed 4 Press MENU repeatedly until SEriAl is displayed 5 Press SELECT bAUd is displayed Press MENU repeatedly until Auto is displayed Press SELECT Press MENU to display either OFF or ON Oe 0 NIETO Press SELECT Depending on your choice auto print is now either on or off 10 Press MENU to scroll to next desired option or G N to exit 26 Model 915A Indicator User Manual Table 10 1 Table 1 ASCII Control Codes Control Control Control Character Control Character Character Code Character Code Code Code K L N Ji K gt co D 3 o u E o De y N Line Feed ER DE 035 o S Y 98 65 Space 32 27 Model 915A Indicator User Manual 28 Model 915A Indicator User Manual Avery Weigh Tronix Scales for Agribusiness Avery Weigh Tronix USA 1000 Armstrong Dr Fairmont MN 56031 USA Tel 507 238 4461 Fax 507 238 4195 Email usinf
7. Avery Weigh Tronix Scales for Agribusiness Model 915A Indicator User Instructions 29748 0014 Issue AE April 2013 Avery Weigh Tronix LLC 2013 All rights reserved No part of this publication may be reproduced stored in an electronic retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of the copyright owner or as permitted by law or under license Full acknowledgment of the source must be given Avery Weigh Tronix is a registered trade mark of the Avery Weigh Tronix LLC This publication was correct at the time of going to print however Avery Weigh Tronix LLC reserves the right to alter without notice the specification design price or conditions of supply of any product or service at any time All third party brands and product names used within this document are trademarks or registered trademarks of their respective holders 915A_u_en_29591_0012 book Table of Contents Chapter 1 General information and warnings nan cc cc nn nr rc cnn narrar rr 3 Aboutthis manual tii ia ia 3 Text CONVENTIONS mara ai ear a rana dante 3 Special messages oe i a a 3 Customer Service Information tt ttnnnnnnnss anrr ttnrE Enn En nnen 3 Chapter 2 Specifi cat ONS egenen eene LL LELLA LELE 4 Chapter 3 Options icy sce css as eee eed drag EE EE E ee a Sege 5 Chapter 4 Introduction es ie A od eed oe d
8. ELECT That layout is now active 9 Press MENU to scroll to next desired option or G N to exit 24 Model 915A Indicator User Manual 10 2 ASCII The ASCII parameter lets you customize the first line of Layouts 1 2 and 4 You key in the ASCII code number for the character you want to print You can use up to 40 characters in the line The ASCII codes are shown in Table 1 1 Key in 915 915 is displayed 2 Press hidden E key and hold for two seconds 915 E is displayed 3 Press SELECT ConF is displayed 4 Press MENU repeatedly until SEriAl is displayed Di Press SELECT bAUd iis displayed 6 Press MENU repeatedly until ASCII is displayed 7 Press SELECT 1 _is displayed The 1 refers to the first of the 40 characters you can insert 8 Key in the control code from Table 6 and press MENU 2 _ is displayed Following is an example of how to enter Model 915A lt CR gt lt LF gt Enter the following control codes Sequence Control Code Control Character 01 77 M 02 79 O 03 68 D 04 69 E 05 76 L 06 32 SPACE 07 57 9 08 49 1 09 53 5 10 65 A 11 13 Carriage Return 12 10 Line Feed Gi E To edit an existing sequence display the sequence number you want to change key in the new ASCII code number and press SELECT to return to the ASCII display Press the GIN key when you are done 9 Repeat step 8 until all control codes are entered and press SELECT ASCII is displayed Model 91
9. M M PRINT ZERO CLEAR Model 915A Indicator User Manual Use this key to escape back to the gross weight Use this key to record add a displayed weight to the memory Use this key to delete the last recorded weight in memory Use this key to output displayed information to a peripheral device Use this key to zero the scale or clear a keyed in value from the display 5 Cable Connections and Power Requirements Make sure all cables are connected as shown in Figure 5 1 and Figure 5 2 Voltage to the Model 915A must be 10 18 volts DC negative ground only If voltage is between 8 10 volts Lo bAtis displayed on the indicator Dropping below eight volts will cause the Model 915A to automatically shut itself off protecting the battery from being completely drained Consult the Model 915A Service Manual for instructions on disabling the automatic shut off Remote Display RS 232 Connector Optional Weigh Bar Connector 7 pin Pin A 12 VDC Pin B Groun e D Y Alarm Connector Figure 5 1 Indicator with One Weigh Bar Connector Remote Display RS 232 Connecta Optional Weigh Bar Connectors 4 or 5 pins Power Fuse Power Connector Pin A 12 VDC Pin B Ground Alarm Connector Figure 5 2 Indicator with Four Weigh Bar Connectors 8 Model 915A Indicator User Manual 6 Indicator Operation 6 1 Gross Weighing 1 Power up the indicator by p
10. d after motion ceases Two format selectable printouts along with single line programmable 40 ASCII characters To be used with the RD912 remote display Includes optional remote radio receiver and transmitter Two separate inputs on the M915A will each be programmable to function as Zero Tare G N RM M M or Print Frequency 303 MHz Frequency on by key switch causes activation of Input 1 or Input 2 4 Introduction The Model 915A is a general purpose animal weight indicator designed to operate at 12VDC It has a companion remote display called the RD912 The indicator can record 1000 animal weighments and give statistics on count total weight average weight highest weight and lowest weight Figure 4 1 shows the Model 915A front panel Avery Weigh Tronix MEMORY MOTION Avery Weigh Tronix 4 1 Keys Figure 4 1 Model 915A Indicator The front panel consists of the digital display window with annunciators numeric keypad and the following keys ON OFF MENU SELECT ID TARE RM Use this key to power up the 915A indicator Use this key to power down the 915A indicator Use this key to access the menus and scroll right in the menu structure Use this key to make selections in the menus and to scroll down in the menu structure Use this key to access the ID function Disabled Use this key to recall a weight stored in memory Model 915A Indicator User Manual GIN
11. d fiber optic back lighting annunciators GROSS TARE NET ID MEMORY MOTION TOTAL AUTO LB and KG One two or five times per second 0 1 of applied load or one division whichever is greater 01 of capacity 01 of capacity one division whichever is greater Typical 12 VDC 95 mA 1 14 watts 12VDC 180 mA 2 16 watts for 5 pin 4 weigh bars Range 10 DVC 89 mA 0 9 watts to 18 VDC 555 mA 10 watts Negative ground system 20 F to 140 F 29 C to 60 C to 95 non condensing humidity Ten 350 ohm Weigh Bars Front panel calibration and spanning for all types of weigh bars and load cell applications up to 999999 Ib or kg 01 02 05 1 2 5 1 2 5 10 50 100 200 500 Ib or kg 1 mV V via front panel push button 0 20 mV V to 1 0 mV V full scale OFF 0 5 1 0 2 0 3 0 5 0 10 0 divisions OFF 0 5 1 0 2 0 3 0 5 0 10 0 divisions Normal intermediate and high Comes on standard in the Auto Accumulate Print mode when Auto Accumulating takes place Model 915A Indicator User Manual 3 Options RS232 serial output Remote Display Output Remote XM710 L XM910 Model 915A Indicator User Manual Includes battery backed up time and date Baud rate selectable 9600 4800 2400 1200 600 and 300 xon xoff 8 data bits one stop bit no parity Initiate serial transmission through print button enquire characters and auto print after accumulate an
12. ee dee ee ENER ENEE caidas 6 ENEE E IE aaa EE n A T AES 6 Chapter 5 Cable Connections and Power Requirements non nnnncnnnnn 8 Chapter 6 Indicator Operation eee ce eee tt ee tee ene ASA Et SEEE EEE EEEEEEEESAE EAEE EE EAEAN ESRAR SEEE EEE EEEn EEn 9 Gross Weighing A sesaran EEEE e A AE 9 ID Number Entry drr ena aT Catia 9 Miew Current D NEE 9 SEEE A D AAE E et EEN dee SEENEN 9 Animal WEIGHING EE 10 How to View Individual Animal Weights ooooonnncccnnnnnncccnnnnnocccccnnnanrccccnn nr ccnnnnn nn 10 How to View the Animal Statistics 11 Printing Repos fusca Seis cela lecita 12 Clear all Statistics from Memory c ooccocnnnnccccnnnnaccconnnononcncnnn aaaea EARE nana rra 12 Setting te ET 13 Viewing and Setting the Time i 13 Viewing and Setting the Date iii 13 Checking Battery Voltage ui i 14 Diagnostic Tests aore la ini ora 14 Chapter 7 Troubleshooting 16 Power On Fare tice fata ata alli at 16 Stalled Display Following Power On 17 indicator ee EE e EE 18 Inaccurate Weight Readings tenets conan nc cnc canon nn n rc cnnnn nn rrnnnn rca 18 Alarm Light FUNCION TTT 19 Measuring Supply Battery Voltage nan cnc nnnnnnnccnnnnnnns 19 Service EES Eeer AA A A tee ede Pe a 19 Display Messages meciiiccniciinra aaa 20 Chapter 8 Miscella
13. ee in this manual EY gt NOTE This is a Note symbol Notes give additional and important information hints and tips that help you to use your product 1 2 Customer Service Information 24 hours a day 7 days a week Customer Support Avery Weigh Tronix is dedicated to customer service We understand downtime is not an option for AG producers and we re ready to help anytime The technical support team for all Avery Weigh Tronix agri business scales is available 24 hours a day 7 days a week Ag Technical Support Group USA and Canada Toll free Phone 800 458 7062 Outside USA 507 238 8261 Tech Support Phone 7 00 am to 5 00 pm CST 800 458 7062 Ext 8261 Tech Support Phone after hours answering 5 00 pm to 7 00 am CST 800 458 7062 Service e mail usservice awtxglobal com Model 915A Indicator User Manual 3 2 Specifications Indicator Enclosure Display Display Rate Accuracy Linearity Repeatability Power Requirements Environment Weigh Bar Drive Capacity Calibration Divisions Zero Balance Range Analog Span Automatic Zero Tracking Motion Detection Window Motion Filtering Alarm Output Impact dust and water resistant structural polycarbonate enclosure stands up to inclement weather and high vibration mobile farm applications Standard Weigh Tronix mounting bracket Dimensions 8 75 high x 10 5 wide x 6 5 deep 8 digit seven segment LCD 1 0 inch high characters 10 annunciators an
14. he gross net mode Model 915A Indicator User Manual 15 7 Troubleshooting If you experience problems in the operation of your system read through these troubleshooting steps and perform those which are appropriate This information may help you to correct the following operational difficulties without calling your supplier or sending your equipment in for repair Power on Stalled Display Following Power on Indicator Lock up Inaccurate Weight Readings Alarm Light Malfunction Measuring the Supply Battery Voltage Instructions for sending an indicator in for repair are provided in the last section under Service Repairs 7 1 Power On Failure If your indicator doesn t power on check the following possible problem sources in the order given Attempt to power on after trying each of these four troubleshooting steps 1 16 Check Battery Voltage Required voltage is 10 18 volts DC negative ground If the voltage is between 8 10 volts the indicator will display Lo bAt The indicator will automatically turn off if the incoming voltage drops below 8 volts or rises above 18 volts Disconnect and Check Power Cable Connector at the vehicle or AC to DC converter clean if necessary and reconnect Replace Fuses Sometimes a bad fuse can be recognized by an obvious break in the wire filament However such a break is not always observable and getting a successful power on after changing a fuse is often the only way of knowing that
15. he weight is automatically stored in the first available record 1 1000 The display will show the record number and the locked weight until the weight drops by 20 or more At this point the display returns to live gross weighing and the alarm light turns off In this mode the M M keys are disabled With Auto LOC off After the animal walks on the scale you must press the M key to record the weight The memory channel and weight will remain displayed and the alarm light will come on for two seconds You cannot record the weight again until the weight drops by 20 If you try the display will show Can t If you want to erase a weight you recorded in error press the M key The display will show the count with the new locked on weight This can be done with or without the animal on the scale 6 3 1 How to View Individual Animal Weights 10 Follow these steps to view each animal s weight 1 From gross weighing mode press the RM key The last recorded weight and channel number is displayed 2 Press the M or M key to scroll through the list of animals and their weights To scroll more rapidly through the list press and hold the M or M key 3 Press the G N key to return to gross weighing mode Model 915A Indicator User Manual 6 3 2 How to View the Animal Statistics Once you have recorded a series of animal weights you can view the results by entering the StAts item in the user menu See Figure 6 Under STATS y
16. neous Information nn nncnnnn 21 Mounting the Model 915A _ i 21 RD 912 Remote Display 22 Optional Radio Remote Transmitters XM710 L and XM910 and Receiver 22 Chapter 9 User s Menu iii 23 Chapter 10 Appendix A Customizing Printouts nn nccnnnnn 24 E ele TE fa tardi analisi nia 24 ASGI ii TORRI Oi 25 To Delete All ASCII Characters rra nnnannnnnns 26 Enabling Te E LEET 26 Model 915A Indicator User Manual Model 915A Indicator User Manual 1 General information and warnings 1 1 About this manual This manual is divided into chapters by the chapter number and the large text at the top of a page Subsections are labeled as shown by the 1 and 1 1 headings shown above The names of the chapter and the next subsection level appear at the top of alternating pages of the manual to remind you of where you are in the manual The manual name and page numbers appear at the bottom of the pages 1 1 1 Text conventions Key names are shown in bold and reflect the case of the key being described This applies to hard keys and onscreen or soft keys Displayed messages appear in bold italic type and reflect the case of the displayed message Screen labels and labels within screens appear in italic type and reflect the case of the displayed label 1 1 2 Special messages Here are examples of messages you will s
17. o awtxglobal com www agscales com Avery Weigh Tronix UK Foundry Lane Smethwick West Midlands To access manuals on England B66 2LP the Ag website Tel 44 0 8453 66 77 88 Fax 44 0 121 224 8183 Email info awtxglobal com www averyweigh tronix com
18. ou can view the following by using the SELECT and MENU keys total count of animals weighed e total weight of all animals weighed average weight of all animals weighed highest recorded animal weight lowest recorded animal weight 1 From gross mode press MENU and StAts is displayed 2 Press SELECT E H tz da Model 915A Indicator User Manual The first stat Count is displayed Press SELECT to see the total number of animals weighed Press SELECT again to return to the StAts display Press MENU to go to the next stat Repeat steps 3 5 to see all the stats Press G N to return to the gross weighing mode 11 6 4 Printing Reports ST MODEL 9154 ID 12345678 02 0313 10 12 02 goa 684 lb epa 788 lb 9003 699 lb 9004 79 lb 9005 915 lb 0006 624 lb oe 787 lb oe 679 lb 9009 845 lb go 914 lb COUNT odia TOTAL 7716 lb AVERAGE fel lb HIGH 915 lb LO 624 1b Layout 1 6 5 Clear all Statistics from Memory 12 To print out a report press the PRINT key One of the following layouts will be printed depending on which you have chosen through the configuration menu See Appendix A for instructions on choosing a layout NOTE If AUTO PRINT is enabled see your Appendix A and AUTO LOC is on Layout 3 shown at right is printed as soon as an animal s weight is stable if Auto Loc is off when pressing M Layout 3 is automatically printed You can customize the first line in the
19. ours minutes and seconds For example 1 59 would be entered as 15900 4 Press SELECT Hour is redisplayed 5 Press G N to return to gross weighing mode 6 8 Viewing and Setting the Date 1 From gross mode repeatedly press MENU until Date is displayed 2 Press SELECT The date is displayed in month day year For kg day month year 3 To change the date key in the new numbers 4 Press SELECT Date is redisplayed 5 Press G N to return to gross weighing mode Model 915A Indicator User Manual 13 6 9 Checking Battery Voltage 1 2 From gross net mode repeatedly press MENU until battErY is displayed Press SELECT The input voltage of the battery or power source will be displayed Voltage to the Model 915A must be 10 18 volts DC If voltage is between 8 10 volts Lo bAt is displayed on the indicator Dropping below eight volts will cause the Model 915A to automatically shut itself off protecting the battery from being completely drained 6 10 Diagnostic Tests There are four tests available to assist troubleshooting in these areas 3a OR 3b Aa OR Ab 14 O display O buttons O serial O relay From gross net mode repeatedly press MENU until tESt is displayed Press SELECT diSPIAY is displayed This is the display test Press SELECT to perform a test of the display segments and annunciators The display alternately lights all the display segments and annunciators Press SELECT to end
20. pairs If you find the indicator or one or more of the Weigh Bars to be defective contact your supplier or send your equipment back to the factory for repair postage prepaid Include the following information 1 Your name and address 2 Supplier name and address 3 Date of purchase 4 Important An informal note describing symptoms of the problem Model 915A Indicator User Manual 19 7 8 Display Messages 20 l Error Indicator is being reinitialized Message is displayed briefly at time of power on Indicator is in state of over capacity Indicator is in state of under capacity System is not functioning properly Weight is not being calculated because scale weight is too high or too low Refer to information on Indicator Lockup in Troubleshooting section of manual Indicator is transmitting data Appears after pressing the PRINT key when printing all memory channels Displayed when attempting to tare when a gross weight is negative or when motion is occurring Model 915A Indicator User Manual 8 Miscellaneous Information 8 1 Mounting the Model 915A The Model 915A mounts on a quick detach bracket Weld or bolt the quick detach bracket into place as follows 1 Choose a mounting location that is convenient for operation of the indicator and protected from moving parts or from other moving machinery Hold the indicator at the proposed mounting location and verify that the display is legible and
21. ressing ON Indicator powers up in mode that was active prior to turning off 2 Verify the scale is empty and zero the scale by pressing ZERO 0 is displayed Zeroing can only occur if there is no motion on the scale 3 Place weight on the scale Gross weight is displayed 6 2 ID Number Entry You may enter an 8 digit numerical ID number to be included in the printouts 1 From the gross weighing mode use the keypad and enter the ID number ID number is shown on the display 2 Press ID The D annunciator is turned on ID number is displayed for 2 seconds then returns to the gross mode 6 2 1 View Current ID En If no ID is currently programmed then ID key displays no ld for 2 sec and returns to the Gross mode 1 Press ID Current ID is shown for two seconds and then returns to the gross mode 6 2 2 Clear Current ID 1 Press ID to display current ID Current ID is displayed 2 Press ZERO CLEAR while ID is displayed ID is cleared and returns to gross mode Model 915A Indicator User Manual 9 6 3 Animal Weighing Ex You can perform animal weighing with Auto LOC on or off See the section Configuring Auto Loc NOTE Layout 3 shown in Printing Reports will be printed if you press M with Auto Print enabled It will also be printed if Auto Loc is enabled With Auto LOC on As the animal walks on the scale and the weight stabilizes the alarm light comes on for two seconds and t
22. the fuse was indeed defective Make sure new fuses are the proper size and have a current rating of five amperes Using a fuse with too high a current rating can cause costly damage to the indicator and will void your warranty The same is true for substituting wire a nail or any other object in place of a fuse Place nothing in the fuse connector except a proper fuse Change one fuse at a time see instructions below Try to power on after changing the first fuse if unsuccessful change the second fuse and try to power on again If changing the second fuse fails to allow successful power on proceed to the next trouble shooting step Model 915A Indicator User Manual To replace a fuse first locate fuse caps on the bottom panel of the indicator Then 1 Turn cap counterclockwise and lift out fuse amp cap assembly 2 Remove old fuse from cap and insert new fuse 3 Replace fuse amp cap assembly in fuse connector 4 Test Indicator and Cables to isolate the source of the problem a Disconnect all cables on bottom panel of Indicator except for power cable Do disconnect Weigh Bar cables and if present alarm cable and printer remote display cable b Now try powering on If this is not successful your problem is in the indicator and you should contact your supplier c If you are able to power on with only the power cable connected your problem is most likely not in the indicator continue troubleshooting d With
23. the test Press MENU twice to go to the next test buttonS is displayed This is the buttons test Press SELECT to perform a test of the front panel buttons When you press any key that key name will appear in the display Press MENU to stop the test Display will show SEriAl Press MENU to go to the next test SEriAl is displayed SEriAl is the serial test This will tell you if pins 2 and 3 are connected If they are connected loop is displayed when you press SELECT no loop is displayed when you press SELECT if pins 2 and 3 are not connected Press MENU to go to the next test rELAY is displayed Use this test to check alarm light function Model 915A Indicator User Manual 7 Press SELECT OFF is displayed 9 ZI You can press SELECT at any time to return to the rELAY display 8a 8b 10 11 12 13 14 Press MENU once to cause the light to flash on and off FLASH is displayed Press MENU again to cause the light to stay on on is displayed Press MENU again to shut off the light OFF is displayed Press SELECT rELAY is displayed Press MENU tESt is displayed Press MENU SoFt is displayed This lets you see the part number and revision level of the software Press SELECT First part of the software number is displayed Repeatedly press MENU to scroll through the part number and revision level and return to the SoFt display Press MENU one more time and you are back in t
24. tor to verify that it is tight and making good contact 3 Check between supporting structure and weighing structure for debris that might restrict Weigh Bar movement 4 Make sure the supporting structure and weighing structure do not touch each other at any point except at the Weigh Bars Next Compare weight readings for all Weigh Bars Position a person or heavy object on the platform above each Weigh Bar one bar at a time and compare weight readings for the same person or same object 18 Model 915A Indicator User Manual For each weighing the weight itself will be off center favoring a single Weigh Bar therefore none of the readings will be accurate However your readings obtained by weighing the same person or object above each Weigh Bar should be nearly identical to each other A single Weigh Bar reading that is significantly different from the others is probably defective 7 5 Alarm Light Function If your external alarm works properly but the alarm light fails to illuminate when it should a problem exists with the alarm light Please send in the indicator for repair 7 6 Measuring Supply Battery Voltage To check input voltage to indicator battery voltage 1 Press MENU tArE is displayed 2 Press MENU repeatedly until battErY is displayed 3 Press SELECT Incoming battery voltage is displayed 4 Press SELECT battErY is displayed 5 Press G N to return to weighing mode 7 7 Service Re