Home

M153-1 Buttockmate type2

image

Contents

1. 5 Drain bag Qty 1 Cautions on Use 1 2 3 4 5 6 7 8 9 Use new needle tips when performing injection training with this product Otherwise it may damage the product or cause malfunction Only use water tap water when training with this product Do not use any other solutions besides water Pouring water is allowed only when the green lamp is lit In the other cases never pour water Use the two AA size alkaline batteries Make sure that the positive and negative sides on the batteries are inserted correctly Replace the batteries with new ones when the buzzer sound becomes weak or when the indicator light fades When using this product for training purposes conduct the training in pairs with one person playing the role of the patient and wearing the simulator If the product gets dirty use kitchen detergent or soap on a soft cloth to remove the dirt or stain Do not use solvents such as benzine thinner or polishing powder Handle this product with care because it is fragile and may break if dropped This product does not support practicing the injection technique locating the upper outer quadrant of the buttock This product can be used with Buttockmate M153 If a defect or problem with the product is discovered during use stop using the product immediately and contact Sakamoto Model or an authorized dealer 10 This product is a simulator capable of supporti
2. inside the bag before storing 10 When necessary use the draining syringe to completely discharge the water for example any water drops that remain inside the tube Storage Instructions 1 Most of the water will have been discharged after disposing of the water inside the drain bag However if you are concerned about any moisture that remains inside the drain tube the draining syringe can be used to remove it Thereafter store the product with the buttocks facing upwards 2 Avoid storing the product in direct sunlight or in locations with high temperature and humidity 3 Always remove the batteries when storing the simulator Be careful when storing because if the batteries are not removed during storage the batteries could corrode and prevent the power from turning on SAKAMOTO MODEL CORPORATION Head office 34 Higashitakagicho Shimogamo Sakyo ku KYOTO 606 0865 JAPAN Phone 81 75 701 1135 Fax 81 75 722 5638 E mail info sakamoto model com URL http sakamoto model co jp Overseas Sales Department 9 29 Senbahigashi Minoh City Osaka 562 0035 JAPAN Phone 81 72 729 8350 Fax 81 72 729 8385 E mail trade sakamoto model com
3. M153 1 lt Buttockmate type2 SAKAMOTO MODEL CORPORATION User s Manual 131126 INDEX introduction Table of Contents 1 Purpose Content 2 Cautions on Use 3 Instructions on Use 4 Storage Instructions 5 Please open your parcel and check the main unit and accessories of the product immediately upon receipt If the products are delivered damaged or with parts missing please contact our company or the distributor AARTI WAE TIL Introduction Thank you for purchasing our product Buttockmate type2 Read this user s manual carefully in order to use the product for a long time appropriately This product is closely checked before factory shipment However when this product arrives open it soon and check if anything on the main unit and accessories are missing or broken Table of contents Introduction Table of Contents cccceceeeseeeeees 1 Purpose Contentus ot sdet cious 2 Cautions on WU See cca cia ehasseueres eluates cone a 3 Ins trie one Tor WW Sen fren Peters cases dots ese aes 4 Storage Instructions nessies anea a aa 5 Purpose This product is used to perform the following injection training 1 Evaluates correct intramuscular gluteus injection Hochstetter s point and Clarke s points Contents 1 Injection simulator 2 Training belt Qty 1 3 Batteries AA alkaline batteries Qty 2 1 set 4 Draining syringe Qty 1
4. ng advanced medical training However Sakamoto Model does not guarantee the same results during actual treatment 11 Please note that the specifications of this product may be changed without prior notice in order to make improvements to the product Instructions for Use 1 To begin attach the drain bag to drainage outlet on the simulator 2 Insert the batteries into the simulator 3 Turn the simulator s power switch on 4 Fit the training belt onto the waist of the patient or model 5 Fit the simulator onto the person playing the role of patient aligning it with the greater trochanter 6 Only use water tap water when training with this product Do not use any other solutions besides water Pouring water is allowed only when the green lamp is lit In the other cases never pour water 7 Use this product to carry out training 8 The built in indicator light and buzzer evaluate whether the intramuscular gluteus injection was performed correctly or not e The green indicator light turns on when the injection is performed at the correct site including the proper depth e The red indicator light flashes and the buzzer sounds if the injection is performed at the wrong site e Both the red and green indicator lights flash and the buzzer sounds if the injection is performed at the correct site but too deeply 9 After training with this product remove the drain bag from the base and dispose of the water

Download Pdf Manuals

image

Related Search

Related Contents

Cruise 2.0 R/T Cruise 4.0 R/T Mode d`emploi  ガイガーカウンターキット取扱説明書(CKI10G01) 特徴 セット内容  Manuale utente software Centralina programmabile ECU Polini  topstop Type 899. _ _ . _ _ Größe 120  Operating instructions en ja ko zh cn  Samsung SC-DC173 manual do usuário  MANUEL DU PROPRIÉTAIRE  ficha técnica ----------------------- garbisu    カタログ  

Copyright © All rights reserved.
Failed to retrieve file