1. 16 5 E ECONOMY command for setting MANUAL state with TMan equal to T1 present in the status message The replay message reports PROGRAM MANUAL REMOTE ECONOMY On CH140GSM we MAN state flashing for indicating the remote setting and 17 0 coincident with T1 E COMFORT command for setting MANUAL state with TMan equal to present in the status message The replay message reports PROGRAM MANUAL REMOTE COMFORT On CH140GSM we have MAN state flashing for indicating the remote setting and TMan 20 0 coincident with T3 AUTO command for setting AUTO state weekly programming The replay message reports PROGRAM AUTO REMOTE AUTO On CH140GSM we have AUTO state flashing for indicating the remote setting Intellicomfort CH140GSM E HOL command for setting HOLIDAY state daily programming The replay message reports PROGRAM HOLIDAY REMOTE HOLIDAY On CH140GSM we have HOLIDAY state flashing for indicating the remote setting JOL command for setting Jolly state The replay message reports PROGRAM JOLLY REMOTE JOLLY On CH140GSM we have Jolly state flashing for indicating the remote setting E T1l value Sets the temperature value for T1 Value is written DU d form ie DecineUnita decimale for e g T1 19 2 The Dozens can be omitted for e g 9 0 The reply message reports the newvalue of T1 E T2 value Sets the temperature value for T2 Value is written DU d form ie
2. Reset NO YES PG09 con With A or switch from NO to YES Pressing ENTER while is displayed YES all parameters except date and time are brought to the factory settings With ff you pass to page A with ENTER exit the function Relay 2 SMS PG10 Allows you to use the Relay 2 of CH140GSM for different uses in fact connecting the electrical users to the terminals 5 6 7 of the Relay 2 and configuring properly in this submenu is possible to add the accessory functionalities to CH140GSM Available functions are SMS Relay 2 is switched on closes the contacts 5 and 6 and opens the contacts 5 and 7 with SMS command and is switched off i e opens the contacts 5 and 6 and closes the contacts 5 and 7 with SMS command OFF EST Relay 2 is used for temperature control but only if is selected Summer regulation while the relay 1 is only for Winter regulation in this way is possible to use CH140GSM for heating and cooling without changing the electrical connection at the season change Intellicomfort CH140GSM Relay 2 will not execute more SMS commands and PRG Relay 2 will switch on and off all days of the specified ON and OFF schedule in this way can be controlled for example the irrigation system or an aquarium lamp completely independent of other CH140GSM functions For programming the time schedules of ON and OFF select PRG and press the key P will be displayed init
3. with variations of various degrees and based on factor savings for reducing the dissipations during the hours of reduced internal external temperature difference here is required to be used a water delivery temperature of about 70 degrees If instead is required a lower water delivery temperature 50 degrees it has to be used a temperature profile tending to maintain as much as possible a constant temperature the limit is the same during 24 hours in order that the boiler should only continuously compensate the heat losses to the outside and never will have the difficult task of raising the room temperature by several degrees Such profile is suggested particularly for condensing boilers which work properly only with low return temperatures In this case it is recommended to oversize the radiators and to use a pump which ensures a low circulation speed of the liquid in the system The decision of this approach is ultimately the most economically and convenient and depends on many factors and is therefore left to the end user choice However it is recommended to take a very good care of the building insulation of doors and windows in particular with which you may obtain big savings in heating cost 31 32 Intellicomfort SUMMER OPERATION CH140GSM as described above has as its primary task the management of the winter temperature therefore for controlling the boiler of the heating installation However there is a comma
4. DecineUnit decimale for e g T2 20 4 The Dozens can be omitted for e g 9 0 The reply message reports the newvalue of T2 E T3 value Sets the temperature value for T3 Value is written DU d form DecineUnit decimale for e g T3 24 3 The Dozens can be omitted for e g 9 0 The reply message reports the newvalue of T3 E TMAN value Sets the temperature value for MANUAL program Value is written in DU d form ie DecineUnita decimale for e g TMAN 22 0 The Dozens can be omitted for e g 9 0 The reply message reports the new value of TMAN 25 26 Intellicomfort E TJOL value Sets the temperature value for JOLLY program Value is written DU d form DecineUnit decimale for e g TJOL 24 0 The Dozens can be omitted for e g 9 0 The reply message reports the new value of TJOL E HJOL value Sets the hours value for JOLLY program Value is written in DU form ie DecineUnit for e g HJOL 12 The Dozens if equal to zero may be omitted for e g 8 The scheduled number of hours JOLLY replaces the hours or the days that were previously set manually or by SMS The reply message reports the new value of HJOL E DJOL value Sets the days number for JOLLY program Value is written in DU form ie DecineUnit for e g DJOL 8 The Dozens if equal to zero may be omitted The scheduled number of days JOLLY replaces the hours or the days that were previously set manually or
5. by SMS The reply message reports the new value of DJOL COMMANDS FOR ALARMS B TEL1 XXXXXXXXXX sets the first telephone number to which has to be sentthe messagerelatedto alarms Replace with the telephone number to be stored in the memory Please note that the command has to end with the character asterisk B TEL2 XXXXXXXXXX sets the second telephone number to which has to be sentthe message related to alarms Replace with the telephone number to be stored in the memory Please note that the command has to end with the character asterisk E TEL1 cancels the telephone number 1 previously stored E TEL2 cancels the telephone number 2 previously stored Intellicomfort CH140GSM TEL is used for knowing the stored telephone numbers AL1 0 TEL1 TEL2 sets the sending condition for alarm1and to which numbers has to be sent In this case an alarm will be sent at contacts closing to TEL1 as well to TEL2 The choice ofthe sending condition is done according to the following 0 sends alarm at contacts closure 1 sends an alarm at contacts opening 2 sends an alarm case of contacts closing or opening TEL1 TEL2 the alarm will be sent to the two stored telephone numbers Always insert the expression TEL1 TEL2 even if was set only one telephone number AL2 0 TEL1 TEL2setsthesendingconditionforalarm2andtowhichnumbe
6. from Tj programming to the programming of Jolly period duration from zero to 240 hours equivalent to 10 days With and W may be varied Tj between 2 and 40 and the duration steps of 1 hour m PROG KEY USING gt gt PROG briefly pressing SETUP Winter PAG1 Set with W switches from Winter to Summer and vice versa with f the page is changed with ENTER the device exits PROG HH hours flashing MM PAG2 SEt with the hours are increased cyclically with W the hours are decreased cyclically with p gt the page is changed with ENTER the device exits PROG Min HH MM flashing PAG3 Set with A the minutesareincreasedcyclically with W theminutesaredecreased cyclically with p gt the page is changed with ENTER the device exits PROG Year AAAA PAG4 Set with the years are increased with W the years are decreased with gt the page is changed with ENTER the device exits PROG Months MM PAG5 Set with A themonthsareincreasedcyclically with W themonthsaredecreased cyclically with gt the page is changed with ENTER the device exits PROG Day GG PAG6 Set with the days are increased cyclically with W the days are decreased cyclically with Pb the page is changed with ENTER the device exits PROG NOTE with the prescribed date the chronothermostat automatically determines the day of the week Intellicomfort Ora Leg SI PAG7 Set Selects automatically the daylight savin
7. in the figure 5 see page 5 fix the base on the wall or in the embedded box using the provided screws replace the insulating protection tightening the screw opentheSIM compartment onthe back ofthe chronothermostat as showninthe figure 2 inserta 51 n b page 4 respecting the direction shown in the figure 3 see page 4 and close pressing easy the holder of the SIM card bring the Switch 1 in position ON figure 4 see page 4 in order to connect the lithium battery already present chronothermostat s body to the power supply circuit hang up pressing CH140GSM body on the base installed on the wall restore the power supply of the electrical circuit gt figure 1 gt figure 2 push to release Intellicomfort gt figure 3 gt figure 4 o A N B Used SIM card corresponds to the standard GSM 11 12 phase 2 practical any SIM card of the standard mobile telephony operators except the cards of USIM 36 operator You may have a contract with rechargeable option case check SIM card credit or a subscriber s contract just removing the PIN code In addition must be enabled the SMS service before inserting the SIM card in the device is advisable to test it by using in mobile phone trying to send and receive SMS messages NOTE After inserting the SIM card and turning on the 14065 the SMS messages not yet delivered or sent in t
8. m to control the home temperature to program the home temperature W to receive notification about changes of the two alarm contacts status for e g a boiler alarm an antitheft alarm a low temperature alarm a boiler malfunction an alarm for sewage tanks overflow etc m toturn or off an external user at 230VAC 500W such as irrigation system through an internal relay CH140GSM allows a remote user to send an SMS with the possibility to know only the system state or to command the state to be located in During the whole remote control on CH140GSM display appears several times the inscription Received Remote Command GSM antenna symbol flashes quickly on the display if isn t possible to register to GSM network low network level CH140GSM is installed in a not reachable location no SIM card inserted or invalid SIM card etc The flashing becomes slower if the chronothermostat is properly connected to the GSM network In addition from two minutes after turning on the device for about 7 minutes you will see a measure of field intensity with a maximum of three accessed bars next to the antenna symbol Intellicomfort CH140GSM SMS COMMANDS SMS messages used to manage CH140GSM chronothermostat are the following STATUS allows knowing CH140GSM alarms and relay state Whenwas sent such message CH140GSM in less than one minute responds with two state SMS composed as follows an example of real operation
9. nu WEEKLY CHRONOTHERMOSTAT WITH INTEGRATED GSM MODEM 14065 INDEX INSTALLATION Intellicomfort CH140GSM ELECTRICAL CONNECTIONS page 3 page 5 BUFFER BATTERY FUNCTIONING QUICK PROGRAMMING GUIDE page 5 page 6 keys description time and date setting page 6 page 6 operating programs set temperatures page 7 page 8 operating programs setting FEATURES IN DETAIL page 8 page 11 available programs page 11 customizable temperatures page 13 keys and advanced functions page 14 reset page 21 REMOTE PROGRAMMING THROUGH SMS SMS commands page 22 commands for alarms page 23 page 24 FOR KNOWING MORE PACKAGE CONTENT m 1 chronothermostat m 2screws m 1usermanual page 25 Intellicomfort CH140GSM 1 INSTALLATION CH140GSM chronothermostat must be installed onthe wall orina3 moduleorround embedded box at a height of about 1 5 m above the floor PERFORM THE FOLLOWING STEPS gt gt gt gt gt gt gt gt gt gt gt disconnect the power supply of the electrical circuit acting on the main switch of the electrical panel remove the back base from chronothermostat body using a tool on the corresponding slot see Figure 1 remove from the base the insulating protection unscrewing the proper imperishable screw make the electrical connections as shown
10. of the program these two values can be changed with the keys amp and W In MAN program the fixed temperature TMan may be changed by means of the keys V Intellicomfort CH140GSM gt CURRENT DATE AND TIME MODIFICATION Press briefly the button PROG to enter the Setup menu where it is possible to change the time date winter summer operation and utomatically daylight saving function gt CUSTOMIZATION OF AUTO WEEKLY PROGRAMMING AND HOLIDAY DAILY PROGRAMMING Hold pressed the key PROG until appears the inscription Config In this menu you can program the weekly AUTO program and daily HOLIDAY program profiles and set the advanced functions for their description see the following sections NOTE if appears the word Setup instead of Config it has been pressed too briefly thekeyPROG nowyoumustpressENTERforreturningtothenormaloperatingstatus and try again Entering the Config menu appears the page that allows choosing the desired temperature T1 T2 T3 Ta for every half hour of the indicated day from 1 to 7 for indicating the days from Monday to Sunday NOTE T1 T2 T3 Ta are displayed on the right side of the display with the symbols E IEEE By means of the keys and you may move from half hour in half hour to the right or to the left Usingthe keys A and W you may pass from one programmedtemperatureto another Through the key PROG briefly pressing is possible to pas
11. probe has been connected EC18 EC19 or EC20 of Fantini Cosmi to Auxiliary probe terminals With this setting you can specify which probe will be used by the chronothermostat for temperature control normally is used the internal probe of CH140GSM Int on the display but is possible to select also the external auxiliary probe Ext by pressing the keys or W This can be useful for example when you can not install the chronothermostat in the desired place for maintaining effectively the set temperature In this way on the central side of the display is shown the temperature measured by the external probe and CH140GSM performs temperature control based on this probe and ignoring the internal one With gt you pass to page 8 with ENTER exit the function Intellicomfort Blocking NO Yes PG08 con It allows locking of the keyboard with a numeric code 4 digits This works only once then should be enabled again With AA W you switch from NO to YES then with ENTER is required the password inserted by means of the arrows or V selecting the digits with P gt and d With ENTER memorize it turning back the display in normal operation that appears only pressing the key ENTER Pressing will require the password which will be inserted by means of the arrows and W followed by ENTER The display returns to normal programming allowing all functions With f you pass to page 9 with ENTER exit the function
12. with much longer time because the environment is becoming warm or cool Consult your installer for a proper programming OPERATION PRINCIPLE CH140GSM continuously measures the ambient temperature and compares it with the temperature required for having at that time If the ambient temperature is lower than the desired one the chronothermostat commands the boiler to turn on and keeps it operating until the ambient temperature reaches the required one CH140GSM is connected by means of two wires to the boiler and boiler s control is done through an open contact boiler turning off when is reached the set temperature upper threshold and when the contact is closed boiler turning the boiler needs to produce heat because the temperature has dropped by a tenth of a degree below the set value lower threshold The radiators may be warm cold in the moment of temperature decreasing from the value above the threshold to the value below the threshold i e when the boiler is turned off Do not be surprised if for some moments the radiators aren t hot is not a system malfunction This may happen especially during the days with the outside temperature not too rigid It is recommended in case of doubt to check if the room temperature indicated by CH140GSM is the required one Intellicomfort 14065 It is also advisable to a thermometer placed the most suitable location for measuring the room te
13. 2 to 40 C while the fourth T antifreeze can vary from 2 to 7 C or can be set to OFF the system is turned off The MANUAL program has a specific temperature as well has the program JOLLY Tj which are set in their corresponding screens and can take values from 2 to 40 C The ANTIFREEZE OFF program instead follows with the temperature TA as mentioned before can vary from 2 to 7 C alternatively can be set to OFF this meaning the completely shutdown of the system OPERATING PROGRAMS SETTING gt PROGRAM SELECTION Pressing the button SEL are selected in cyclic order different operating programs AUTO gt MAN OFF gt HOLIDAY gt AUTO NOTE thetemporaryprogram JOLLYisnotincludedinthesequenceofprograms but may be selected directly with JOLLY key gt TEMPERATURES SETTING During AUTO HOLIDAY and OFF programs press TEMP key to change the values of the four programmable temperatures pressing several times the key TEMP appear in sequence the values T1 T2 T3 Ta position under T if you wish to modify the parameter and use the arrows W for increasing or decreasing the temperature by 0 1 C increments Return to the initial position with the arrow d Take into consideration that T1 will be always less or equal to T2 2 less or equal to T3 In JOLLY program TEMP button alternates the visualization of the set temperature Tj and the hours left until the end
14. U microdisconnection Software class A Minimum regulation differential 0 1 C Reference thermal gradient 4K h Maximum room temperature T45 Electrical insulation double insulation Protection degree 20 Pollution degree 2 Pulse voltage 4000V Complies with the standards Installation EN 60730 1 and additional parts Directive R amp TTE EN 301 489 1 EN 301 489 7 EN 301 511 on the wall Dimensions 68 x 52 5 x 58 mm Quad band EGSM850 900 1800 1900 MHz Output power Class 4 2W for 850 900 MHz Class 1 1W for 1800 1900 MHz Sensibility 107dBm 2850 900MHz 106dBm a1800 1900MHz Connections Power supply connector 2 5mm AWG 14 Inputs Outputs connector 2 5mm AWG 14 This product is not manufactured in Italy 33 34 Intellicomfort Intellicomfort CH140GSM mu COSMI 5 Via dell Osio 6 20090 Caleppio di Settala Milano Tel 39 02 956821 Fax 39 02 95307006 info dfantinicosmi it supportotecnico dfantinicosmi it www fantinicosmi it C 5679534 GB
15. be programmed through the key TEMP from an OFF value the boiler is always turned off toa range between 2 0 and 7 0 C with a precision of 0 1 C using the arrows and W The viewed window is gt Ta x x hour min Tamb Keeping more time the arrows pressed the value rapidly increases or decreases automatically For returning to the window OFF press the arrow 4 Pressing again the key OFF the unit returns to the previous operating state RESET Due to unpredictable and unusual events is possible that the device needs to be restarted e g in case of blocking as a result of a strong electromagnetic interference in this case you can act by pressing the little round button RESET positioned on the right side of the device see figure using a paperclip or a pin the device restarts the operation with the words Fantini Cosmi CH140GSM for some seconds then goes to AUTO mode The entire previous configuration is retained as was memorized by the chronothermostat w Date and time are not normally modified If instead you wish to return to the factory settings the system will be restarted with the RESET command in PROG CONFIG menu where from you exit the AUTO state Inthis case all settings and customizations made bythe user will be lost and replaced with the factory settings except for the date and time 21 22 Intellicomfort 6 REMOTE PROGRAMMING THROUGH SMS By using GSM function is possible
16. blackout Intellicomfort 4 QUICK PROGRAMMING GUIDE KEYS DESCRIPTION The chronothermostat is equipped with 6 keys whose functions varies depending on the situation and is described by the symbol that appears on the display according to the key 65 day of the week relay ON summer ON winter graphic portion messages temperature time profile Celsius Fahrenheit room temperature programs battery charge symbol time secondary function summer winte primary function 6 functional keys N B first pressing of a key doesn t cause any action except for the one that turns on the display light in order to allow a better view TIME AND DATE SETTING After switching on the device press briefly the PROG key appears the inscription Setup now press the key gt to enter on the page Hours Use the buttons W for setting the hour and than press P for passing to Minutes setting Press again PP for selecting in sequence the Year Month and Day Pressing gt you may choose to disable the automatic change of summer solar time initially this function is active but you can disable it by choosing NO by means of the keys A and W It is always possible to return to the previous page by pressing the button d To exit the Setup menu press ENTER Intellicomfort 14065 OPERATING PROGRAMS CH140GSM chro
17. ced in the desired area With A and it is modified the temperature value on the display With fj you pass to page 3 with ENTER exit the function Celsius PG03 XX X Allows youto choose the temperature scale to be displayed between Celsius degrees and Fahrenheit degrees With or W you pass from Celsius to Fahrenheit With you pass to page 4 with ENTER exit the function Intellicomfort CH140GSM Light OFF ON Xs PG04 con With this function is possible to adjust the display backlighting blue light You may choose to not have it OFF to have it with a programmable duration between 1 and 9 seconds or for having it always ON When the backlight is set to always ON or always OFF to access various functions is enough to press once the keys With or is possible to pass from OFF to ON choosing the duration 1 9 sec always ON With Pe you pass to page 5 with ENTER exit the function Int Light X PG05 con Allows you to modify display brightness up to 9 levels With or W is possible to change the brightness level 1 9 With gt you pass to page 6 with ENTER exit the function Italiano PG06 con Allows you to change the language used during programming With or is possible to pass cyclically from language to another With gt you pass to page 7 with ENTER exit the function Probe Int PG07 selected temperature probe This submenu page is available only if a temperature
18. d off toarange between 2 0and7 0 C withaprecision of 0 19 using the arrows amp and W The device returns to OFF status using the arrow q Pressing the button OFF it returns to the previous operating status gt ALTERNATIVE VIEWS During AUTO and HOLIDAY programs other information can be displayed instead of the temperature profile pressing several times the key DISP At the first pressing appears the temperature programmed for the current half hour at the second pressing appears the enlarged temperature profile one hour before to three hours after the current half hour at the third pressing the date is displayed at the fourth the status of the two alarm inputs 11 for Input 1 and 12 for Input 2 On if are open Off if the corresponding contacts are closed in short circuit at the fifth the status of the two relays 01 for Output relay 1 and 02 for Output relay 2 for closed contacts 1 and 2 and Off for open contacts 1 and 2 at the sixth it returns to the initial temperature profile Intellicomfort CH140GSM 5 FEATURES DETAIL AVAILABLE PROGRAMS CH140GSM has several operating modes programs m weekly program AUTO daily program HOLIDAY temporary program JOLLY manual program MAN switched off system or with antifreeze program OFF ANTIFREEZE gt WEEKLY PROGRAM AUTO In AUTO operating mode may b
19. daily changes In case if is required the system switch off e g second houses you may bring your CH140GSM state called OFF in which you choose either the boiler is always turned off the boiler provides an antifreeze temperature programmable recommended around 5 6 degrees particularly in mountain areas where the temperature drops easily below zero there may appear the possibility of water freezing in the pipes and accordingly their breakage Ifyou want to manually set on 24 hours for an unlimited term the desired temperature toa fixed value may be used the program that makes the system to operate in manual MANUAL mode If instead you want to operate the system to a desired temperature fixed for a limited period of time may be used the JOLLY program setting the hours number of this operation 29 30 Intellicomfort CH140GSM POSITIONING IN A CIVIL HOUSE CH140GSM is an embedded device therefore very compact For its correct reading and programming it should be installed at a height convenient for such operations about 1 50 1 60 meters keeping in mind that at this height the measured temperature can be slightly higher than the reference temperature of the environment For this purpose exists the possibility to introduce a correction of the measured temperature in order to bring it back to that of the reference Normally the chronothermostat is located in the central position of the apartme
20. e used 4 temperature levels Ta T1 T2 T3 according to aschedule of 30 minutes increments about 24 hours to 7 days The days are numbered from 1 to 7 and correspond to seven days of the week starting from Monday In order to simplify the programming it is possible to set the first day and copy it onthe following days The default values for the days 1 5 from Monday to Friday 00 00 06 30 T 06 30 09 00 T2 09 00 11 30 T winter program C Monday Frid 11 30 14 00 T2 n onday Friday 14 00 17 00 T 1219 17 00 22 30 T3 T117 22 30 24 00 T 0 6 30 911 30 14 17 22 30 24h while the default values for the days 6 7 Saturday and Sunday 00 00 08 00 T1 winter program i C Saturday Sunday 08 00 11 30 T2 11 30 23 00 T3 T219 23 00 24 00 T 1 17 8 11 30 23 24h The values of the 4 temperatures can be customized using the function TEMP Intellicomfort The temperature profile time variation can summer program i i c Monday Frida be programmed using the function PROG y y 2 26 T1 24 0 5 8 18 30 22 30 24h In case of summer operation cooling the default program is shown as in the figure gt DAILY PROGRAM HOLIDAY During HOLIDAY operating mode can be used 4 temperature levels according to a programming of 30 minutes steps around 24 hours per day Here it is obtained a daily programming independently from the days of the week The default t
21. eeze asareference to ensure the system protection at low temperatures Normally TAissetto 5degrees butcanbesettoOFF therebyobtainingthecompletely shutdown of the boiler The weekly or daily schedules remain unchanged CUSTOMIZABLE TEMPERATURES The system involves the use of 4 different temperature levels three of normal use and one called antifreeze for using when is required to keep the boiler off but without the risk of freezing the system liquid The programming of the three T values is conditioned by the reciprocal values in order that T1 cannot higher than 2 2 can not be higher than or lower than T1 can not be lower than T2 It is therefore necessary to pay attention to their programming which is obtained by pressing the TEMP function T1 varies between 2 0 and T2 degrees with variations of 0 1 C default 17 0 T2 varies between T1 and T3 degrees with variations of 0 1 C default 19 0 T3 varies between T2 and 40 0 degrees with variations of 0 1 C default 20 0 TAlantifreeze variesbetween 2 0and 7 0degrees withvariationsof0 1 C oritcanbe OFF i e the boiler remains always switched off default 5 0 Intellicomfort KEYS AND ADVANCED FUNCTIONS m SEL KEY USING SEL button selects chronothermostat s operating mode according to the following programs gt HOLIDAY gt AUTO gt MANUAL gt To change the chosen program pressthe keySEL insequence cycl
22. emperature profile is c 00 00 08 00 T1 T320 08 00 11 30 T2 II 11 30 23 00 T3 23 00 24 00 T1 8 11 30 23 24h Temperature values can be customized using the function TEMP The temperature profile time variation can be programmed using the function PROG gt JOLLY JOLLY mode allows you to set a JOLLY return in AUTOMATIC MODE customizable temperature Tj for a x i number of hours that can be programmed from 1 to 240 It is used when is required a temporary variation of the program 7117 without changing the parameters e g in order to keep a higher temperature more 799 6 30 9 11 30 14 17 time for evening with the friends keeping it lower during an absence in the weekend If you entered JOLLY mode through the corresponding key at the expiry the system automatically returns to the current programming 22 30 24h Intellicomfort 14065 gt MANUAL MAN mode allows you to set in manual mo canlbeisep rom mode a fixed temperature Tman that oc varies between 2 0 and 40 0 degrees without having to expire or modify the weekly or daily programming lt can be used for e g for keeping the house during an absence at a temperature different from those of the daily schedule or to remotely turn on the system bringing it to a constant temperature T321 24h gt OFF OFF mode is used when is required system switch off ItusesthetemperatureTA antifr
23. g time applicable in European countries and others Such predisposition allows to have an automatic knowledge about the time in the moment of changing the time zone March and October with W you may pass to YES or NO With p gt the device returns to page 1 Winter Summer with ENTER it exits PROG PROG long pressing gt CONFIG It presents the display of day 1 with the temperature graph every half hour the indication of the half hour and the associated temperature zi Ee E3 ER Day 1 corresponds to Monday and so on day isthe Holiday day which does not vary during the week With is possible to move forward with half hour With or W is possible to move up or down from tA to t1 to t2 to t3 With PROG briefly pressing you may change the day 1 2 3 4 5 6 7 After you pass to page 2 Correction With PROG long pressing you pass immediately to page 2 With COPY is possible to copy the temperature profile of the current day on the following day From page 2 onward with ENTER for exiting the programming With you return to the previous half hour even to the day before With at the beginning of Day 1 you pass immediately to page 2 Correction PG02 XX X Allows you to change the measured temperature which due to the embedded wall installation and maybe at a non optimal depth may not indicate the real sensed temperature It is recommend to calibrate it by comparing with a thermometer pla
24. he first moments of operation will be deleted without being executed A ATTENTION thetwoauxiliaryinputsmustbeconnectedtovoltage freecontacts dry with cables not longer than 3m 2 ELECTRICAL CONNECTIONS gt figure5 Input 1 alarm Auxiliary relay Input 2 electrical user alarm Auxiliary probe 5 2 54 1 64 6 7L ENS L 1 CH140GSM N als 41 BOILER 230V 50Hz 3 BUFFER BATTERY FUNCTIONING CH140GSM internal battery has the only purpose of enabling the chronothermostat to turn offthe system and remaining in lowconsumption mode during voltage absence In this situation on the display will appear the inscription Blackout If the battery sign started to flash on the display means that the battery is used up contact the nearest Fantini Cosmi Service Center Intellicomfort CH140GSM ATTENTION The installation must be performed by qualified personnel only ATTENTION before proceeding with the electrical connections make sure that the power supply of the installation is disabled by means of the main switch located on the electrical panel N B evenwhen the battery charge is low the chronothermostat will operate normally but will not be ensured system turning off and date time storing during the
25. ially the switch on schedule and the inscription ON press the keys and W for changing the hour and the minute in which the Relay 2 will be turned on every day subsequently press again PP for viewing and changing with and W the switch off schedule now displayed through the inscription OFF 0 1 Relay 2 will turn on if at least one of the two auxiliary inputs Input 1 or Input 2 will be closed in short circuit i e will be OFF Vice versa if both auxiliary inputs are electrically open i e will be ON Relay 2 is turned off 0x1 Relay 2 will turn on if both auxiliary inputs Input 1 and Input 2 will be closed in a short circuit i e will be OFF Vice versa if at least one auxiliary input is electrically open i e will be ON Relay 2 is turned off NOTE keep in mind that the two auxiliary inputs must be commanded in openingandclosingbythe clean electricalcontacts i e voltage free asthe relayorthermostat contacts Otherwise youwillface an irreparable failure of the chronothermostat CH140GSM vX Y GSM Allows you to view the software version of CH140GSM chronothermostat Pressing ENTER the device returns to the normal operating page 20 Intellicomfort With it returns to time profile programming 1 m DISP KEY USING DISP key lets you view only in the AUTO and HOLIDAY states windows with various information also depending on the functioning state The viewed windows are as follows gt Da
26. ic Thefirst3states aremarkedwithasmallinscriptionontheleftside ofdisplay while OFF stateappearsin the graphic area on the top m TEMP KEY USING gt AUTO HOLIDAY and OFF Pressing the key TEMP you enter the programming of the 4 temperatures used in these modes With the arrows and W the temperatures are changed with the condition that T1 can not be higher than T2 T2 can not be higher than T3 or lower than T1 T3 can not be lower than T2 By means of TEMP key the device passes to the following temperature cyclic TPT2TSTeaTl Pressing it will return to the main window gt TEMP long pressing If a temperature probe is connected to the terminals Auxiliary probe it is displayed also the temperature regarding this probe in the upper side of the display This indication remains even changing the type of display pressing the key DISP or changing the operating program Pressing again and holding TEMP key the unit returns to the normal viewing mode Ifitisselectedthe ExternalProbe setting seeCONFIGmenu thetemperature of theinternalprobewillbedisplayedonthetopofCH140G6SM andthetemperature of the external probe will be displayed in the center of the unit It can be connected to Auxiliary probe terminals the following Fantini Cosmi temperature probes EC18 external probe EC19 floor probe EC20 ambient probe gt Intellicomfort CH140GSM In JOLLY Pressing the key TEMP the device passes alternately
27. in AUTO mode FIRST MESSAGE TAMB 22 9 current ambient temperature reading T1 17 0 set temperature T1 T2 19 0 set temperature T2 T3 23 0 set temperature T3 TOFF 5 0 set temperature T Antifreeze TMAN 16 5 set temperature T Manual TJOL 19 0 set temperature T Jolly HJOL 1 Jolly program duration hours DJOL 0 Jolly program duration days PROGRAM AUTO prescribed program on 14065 REMOTE remotely prescribed program PLANT OFF chronothermostat relay state BATT HI CH140GSM batteries state gt SECOND MESSAGE INPUT1 OFF alarm 1 state INPUT2 OFF alarm 2 state OUTPUT OFF relay state This is a standard reply for each sent message As follows are presented only the different lines compared with the message shown above FROST sets the antifreeze program that brings in OFF the system The replay message reports PROGRAM OF F REMOTE OFF On CH140GSM display will be shown the flashing OFF while setting it with SEL will be fixed 23 24 Intellicomfort E RESUME command for returning from the state sent through remote control to the state set on CH140GSM The replay message reports PROGRAM AUTO REMOTE On CH140GSM the display returns to AUTO mode MAN command for setting MANUAL state with TMan set CH140GSM present in the status message The replay message reports PROGRAM MANUAL REMOTE MANUAL On CH140GSM we have MAN state flashing for indicating the remote setting and
28. mperature the temperature indicated by the chronothermostat in fact may be subjected to measurement error due to some factors not just to the location where is installed the embedded box but in particular to the position recessed in the wall the measured temperature in this case is greatly influenced by the temperature of the wall itself especially the first few days after device restarting in some houses that aren t always inhabited where the wall temperature rises much slower than the ambient air The daily profile is programmed in two modes m WEEKLY MODE during which you may define a different temperature profile for each day of the week thus allowing a different programming between the working days from Monday to Friday when you leave the house during the day is possible to keep a lower temperature for this time of absence and during the weekend Saturday and Sunday it is required a higher temperature during the day In this way every day of the week can be programmed individually m DAILY MODE for using it when the presence in the house does not change during the week housewives retirees second houses for vacation and here is programmed a single profile valid for all days of the week N B In case of radiant panel heating the daily programming may not have significant changes during several hours as the system inertia is much higher than that of a system with radiators It is therefore advisable to use profiles with more
29. ms where you do not stay during the day and even during the night you may prefer to have a temperature lower than that of the living room If the temperature obtained in the bedroom by means of the thermostatic regulation is sufficient in normal case it is accepted a temperature that isn t higher than the temperature of the living room no action is needed if instead isn t reached the desired temperature it is suggested to partially close the valves upper or bottom of the radiators from the living room for making the boiler to work more time in this way obtaining the possibility to raise the temperature in other rooms Intellicomfort CH140GSM EFFECT OF THE FLOW WATER DELIVERY TEMPERATURE AND BOILER S WARM WATER As mentioned above normally the water temperature in the radiators is adjusted by the installer according to installation dimensions according to the heat dissipation of the apartment and to the rapidity of obtaining room temperature variations The correct temperature calibration should allow the radiators to pass from a low temperature e g during the night to a higher temperature in a reasonable period of time If the flow temperature is too low it impedes from reaching the desired temperature in the scheduled time In fact the supplied calories are used on two fronts for increasing again the room temperature and simultaneously for compensating heat dissipation to outside heat demand To manage such profile
30. nd that allows you to invert the operation logic in case of its use for managing a summer air conditioning system in this case in fact 14065 must close the contact of the air conditioning control switch when the temperature is higher than the set reference value and open switch off when the temperature is lower Once you set this parameter the programming is identical to the winter operation which simply refers to this manual The intervention differential in summer mode is 0 3 C MAINTENANCE During the blackout power failure periods the programmed parameters will not be lost as all settings are stored in a nonvolatile memory Furthermore CH140GSM is equipped with an internal backup lithium battery which guarantees system shutdown during power failures In these situations on the display will appear the inscription Blackout and CH140GSM remains in a state of standby until voltage will be restored For cleaning it is recommended to use only soft and dry cloth textile Do not use water or other liquids TECHNICAL SPECIFICATIONS Intellicomfort CH140GSM Temperature regulation range 2 40 C increment of 0 1 C T ambient measurement visualization range 35 60 C Power supply 230V 50Hz Maximum power consumption 10 W Connection to the boiler 3 screw terminals closed open Contacts rating 5 3 A 250 Vac Action type 1 B
31. nothermostat allows different working modes called programs m WEEKLY PROGRAM AUTO itis possible to associate to every half hour one of four programmabletemperatures for each day of the week This is the program that appears after turning on the chronothermostatand generally isthe mostfrequently used m DAILY PROGRAM HOLIDAY as in the AUTO program you can select one of the four programmable temperatures for every half hour only this sequence is repeated the same every day a 1 amm LIEMP PROG DISP j j OFF m TEMPORARY PROGRAM JOLLY you can choose to maintain a certain temperature for a determined number of hours after which the device returns to previously operating program W MANUAL PROGRAM the chronothermostat maintains a fixed temperature specified from time to time for an unlimited time until will be selected another program m SWITCHED OFF SYSTEM OR WITH ANTIFREEZE PROGRAM OFF ANTIFREEZE the system remains switched off or alternatively is keeping avery lowtemperature from 2to 7 C inorder to avoid liquid freezing in the heating system 1 1 1 SEL LIEMP j PROG ot 5 LOFF j Intellicomfort SET TEMPERATURES In AUTO and HOLIDAY programs is possible to set four different temperatures and to select one for every half hour of the day Three of these temperatures T1 T2 and T3 can take values from
32. nt in a place as much as possible away from cold spots windows or doors from hot spots radiators or kitchens or away from direct sunlight in order to not be too influenced by these sources TEMPERATURE CONTROL IN OTHER ROOMS There exist some factors that can significantly affect the behavior of the system some of them are related to the house project such as wall and windows insulation the arrangement and the radiating surface of the radiators while other factors are set during installation such as water temperature in the radiators generally these factors are not controlled by the end user but by the designers installers The end user can manage the temperature in different rooms of the house depending on a single chronothermostat CH140GSM usually located in the living room Based on the principle that the radiators in all the rooms have been properly dimensioned i e in order to ensure the same temperature throughout the house there may arise the need to obtain in other rooms a different temperature regulation than the living room In order to obtain the temperature adjustment in other rooms it is recommended to install on the radiators of the corresponding rooms the thermostatic valves that are useless for the living room and can be used only for manual regulation of the present radiators by means of the upper valves with knob and bottom valves with screw Particularly these thermostatic valves can be used the bedroo
33. rs to sendit For choosing the sending condition and to which numbers to send the alarm will be applied the same remarks made for the previous command AL is used for knowing the activation status of the alarms and associated phone numbers MSGIN1 INPUT1 ON OFF allows you to customize the messages related to alarm1 simply by replacing with INPUT1 the alarm description e g INPUT DOORJ andwith ON OFF thetwoconditions forexampletheinscription OPEN CLOSED MSGIN2 INPUT2 0N OFF allows you to customize the messages related to alarm2 simply by replacing with INPUT2 the alarm description e g SHUTTER and with ON OFF the two conditions for example the inscription RISED LOWERED 27 28 Intellicomfort 9 FOR KNOWING MORE WINTER OPERATION CH140GSM is a system for turning on or off the boiler or depending on the systems pump burner or the valve that controls water flow in order to send hot water to the radiators or to the heating panels only when it is required to raise the ambient temperature The flow will be interrupted only when the desired temperature is reached In this section will be discussed in detail chronothermostat s application in the cases more diffuse than the places equipped with radiators Rooms with under floor heating require a different programming related to a different thermal inertia of the system because the under floor heating works with low temperature water and
34. s to the next day DAY 1 gt 2 gt 3 gt 4 gt 5 gt 6 gt 7 gt H Press the key COPY for copying the current day s temperature profile the following day AfterH profile ofthe daily program Holiday youpasstothe parameter correctionpage Intellicomfort With PROG long pressing or with the beginning of Day 1 you go straight to Correction page From Correction page onward with ENTER for exiting the Config menu gt JOLLY PROGRAM SETTING In all programs except MAN by pressing the button JOLLY is selected the temporary program thisprogramallowsyoutodefinethedesiredtemperatureanditsdurationin hours up to a maximum of 240 i e 10 days For example may be useful for maintaining a lower temperature fora whole weekend when is no one home Entering this program you may change the duration which initially is an hour and increase hours number with the key or decrease with the key W Pressing TEMP it is possible to display and modify the temperature Tj using the keys A W Pressing again TEMP the device returns for displaying the duration of JOLLY program After this time expiry the device returns to the previously operating program gt OFF ANTIFREEZE PROGRAM SETTING Pressing the key OFF fromany operating program the chronothermostatswitchesto shutdown antifreeze status The antifreeze temperature Ta is programmable through the key TEMP from an OFF value the boileralways switche
35. y profile hour min Tamb gt Current set temperature e g T3 20 0 hour min Tamb gt 4 hour profile 1 3 hour min Tamb gt Gg Mm Aaaa hour min Tamb gt 12 on off hour min state of the two auxiliary inputs gt 01 02 on off hour min Tamb Relay 1 and 2 state E JOLLY KEY USING JOLLY key allows you to replace in normal operation a temperature stretch to a fixed value for a predetermined time interval The viewed window is gt duration of JOLLY state HH h hour min Tamb With the arrows and W is possible to modify the duration of JOLLY state with 1 hour steps Jolly temperature is set by pressing the key TEMP that leads with viewing the following window 2 Tj xx x Tamb This window will remain on the display until will be pressed again the key TEMP which case the device returns to the previous display indicating the state duration To exit JOLLY state before it expiry you may bring to zero hours number by means of the arrow W and wait a minute to automatically return to the origin state by pressing the key SEL to switch to the state required for operating with the cycle AUTO MAN HOLIDAY OFF Intellicomfort CH140GSM E OFF KEY USING OFF key allows you to bring the system from any operating state to the shutdown state The displayed window is gt Tamb Antifreeze temperature may
Download Pdf Manuals
Related Search
Related Contents
Phonix NL630TFF mobile phone case Spectracide HG-96375 Instructions / Assembly PDF 573 ko 取扱説明書 Descargar Edsal IBU301642 Instructions / Assembly Click to see the Kuma Arctic Owners Manual Masterguard SIIIUSV-Systeme 250 bis 800 kVA Kenmore 318205869A Oven User Manual Harman Kardon AVR 135 User's Manual Copyright © All rights reserved.