1. VA pepco Business User Thermostat Manual Installed by Number of Thermostats Date Comments KA 7 energy wise rewards Call 1 866 353 5798 or visit pepco com rewards Table of Contents Step 1 Getting Started anreisen aoe GIS Ee HR ann E HS ce A E a N a 3 A Thermostat Buttons and INGICAUONS occ caisccercnncnecesnancdnaenicsadaiectcvasbacassacodnasenanecesdllncsiteencanecobeannicestendeendeabeness 3 B Thermostat Display eae nee ee eee e a a E ee i 4 Step 2 User Main Menu and Other Settings cccccccececeeeceee cece eeeeee ence eee eeeeceaeeeeeeeeecneeeseeeeeceseesnieeecieeeeneeess 5 IA User MaM MEMU geresenseer ee depict EE i geiseh hais s ioidai bisigh pana 5 B Other SS etal seende a a a ES Ta bean sonio Sath aoi E a a ia matinee 7 C Description of User and Other Settings Menu Options lt cccc s2ccsanccnsnceeseneeiadecnvseacchecasinenaesenetetesnsnter 8 Step 3 How to Program Your Pepco Energy Wise Rewards Thermostat ccccccccccsscccccsseeeesssseeeeeeeteeeeeeetseaeeeenes 10 Step 4 Temporary Versus Permanent Hold 0 iscdaccuciscatadesdvansubocasdeancitiweds beceubsddasadseadaveetngsdbadastaasibacdhseadsetanoesndenedees 12 Troubleshooting pd thn eae een en cae oe wees sh laoi ath ated nea ee tin Eamonn 13 Your Pepco Energy Wise Rewards thermostat controls your central air conditioning system and your heating system The types of compatible cooling and he
2. Rewards Wait for the Energy Wise Rewards conservation conservation period Event in Progress displayed period to end on top line of LCD System switch is set to OFF Press the thermostat s SYSTEM button one or more times to select HEAT or COOL as appropriate Heat Cool or Fan Runs Constantly Possible Cause Corrective Action Fan set to ON Change Fan to AUTO Thermostat Setting and Thermometer Disagree Possible Cause Corrective Action Thermostat thermometer setting requires adjustment The thermometer can be adjusted 5 degrees See Adjust Temperature Display on page 8 Pepco Energy Wise Rewards Thermostat User s Manual 13 Troubleshooting No Heat Possible Cause Corrective Action Pilot light not lit System switch not set to HEAT Furnace Lock Out Condition Heat may also be intermittent Heating system requires service or thermostat requires replacement If it will not stay lit call for service from your HVAC contractor Press the thermostat s SYSTEM button one or more times to select HEAT and press to raise the temperature setpoint above room temperature Many furnaces have safety devices that shut down when a lock out condition occurs If the heat works intermittently contact the furnace manufacturer or your HVAC contractor for assistance To diagnose this condition Press SYSTEM button to select HEAT and press to raise the temperature setpoint above room temperature W
3. is from 45 F to 99 F e Cool Setpoint 45 F default e Heat Setpoint 99 F default 4 Other Settings Adjust Temperature Display This allows you to adjust the displayed temperature up to 5 higher or lower than the actual room temperature Your thermostat was accurately calibrated at the factory but you have the option to change the display temperature to match your previous thermostat The current or adjusted room temperature will be displayed on the left side of the display while your desired offset will be displayed on the right side of the display Options for this menu item include e 1 through 5 Adjusts the displayed temperature the specified number of degrees higher than the measured room temperature e 0 Default Displays the measured room temperature e 1 through 5 Adjusts the displayed temperature the specified number of degrees lower than the measured room temperature 8 Pepco Energy Wise Rewards Thermostat User s Manual 5 Other Settings Energy Management Recovery Options for this menu item include e OFF Default The system starts heating or cooling at the start time for the program period e ON The system starts heating or cooling before the start time for the program period so that the room temperature reaches the program setpoint at the period start time Example You select EMR ON and have your heat conventional heating system programmed to 65 at night and 7
4. 0 at 7 00 AM a difference of 5 Allowing 7 minutes per degree the thermostat will start calling for heat prior to the 7 00 AM period start time in an attempt to reach the 70 setpoint by 7 00 AM With EMR OFF the thermostat will wait until the 7 00 AM period start time to begin heating the facility 6 Other Settings F C You can display temperature in either e F Fahrenheit Default e C Celsius 7 Other Settings Control Event Pending The phrase Control Event Pending will appear in the message rotation at the top of the display screen before an Energy Wise Rewards conservation period is set to begin The LED at the center of the control arrows will flash until the event begins 8 Other Settings Event in Progress When an Energy Wise Rewards conservation period is in progress the phrase Event in Progress will be displayed in the message rotation at the top of the display screen The LED at the center of the control arrows will maintain a steady light for the duration of the event Pepco Energy Wise Rewards Thermostat User s Manual 9 Step 3 How to Program Your Pepco Energy Wise Rewards Thermostat 1 Press MENU to enter the Main Menu 2 Press or to highlight the Programming menu item Then press Action button to enter the Programming Menu NOTE If the HOME button is pressed at any point during the programming sequence any changes made will not be saved and
5. ating appliances include Central Air Conditioners Furnaces e Single Stage e Single Stage Gas or Oil e Multi Stage e Multi Stage Gas or Oil e Single Stage Electric Heat Pump e Multi Stage Electric e Single Stage e Multi Stage Aux Heat e Single Stage Electric e Multi Stage Electric All compatible components are connected and configured by the Energy Wise Rewards technician during installation ee 2 Pepco Energy Wise Rewards Thermostat User s Manual Step 1 Getting Started A Thermostat Buttons and Indicators me perco Left Arrow Navigates menu items Up Arrow Raises temperature setpoint changes selected menu item Action Button Selects action of selected menu item LED Indicates occurrence of curtailment event Right Arrow Navigates menu items Down Arrow Lowers temperature setpoint changes selected menu item SYSTEM Button Changes system selection OFF COOL HEAT AUX displayed on heat pump units only FAN Button Changes fan setting Auto On Soft Keys Performs action listed on display above the button GSqgeaqaocecs Pepco Energy Wise Rewards Thermostat User s Manual Step 1 Getting Started B Thermostat Display Displays day time thermostat and Pepco related messages In the event of a power Messaging Ara outage the clock will maintain the correct time for 48 hours a Temperature Displays current room temperature E Setpoint Displays current desired te
6. display area to confirm that a temporary hold is set A temporary hold setpoint will then be maintained until the start of the next programmed time period or the RUN soft key is pressed A permanent hold can be set when operating in any mode except for OFF To set a permanent hold change the temperature just like setting a temporary hold When the desired setpoint is entered the user will have approximately 4 seconds to press the PERM HOLD soft key to convert the temporary hold into a permanent hold The SET AT by the setpoint will change to HOLD AT and a message will be cycled in the thermostat messaging display area to confirm that a permanent hold is set If the PERM HOLD soft key is not pressed within 4 seconds the hold will remain a temporary hold and the soft key will change to a RUN soft key A permanent hold setpoint will override the programmed setpoints and time periods and can only be ended by pressing the RUN soft key 12 Pepco Energy Wise Rewards Thermostat User s Manual Troubleshooting No Heat No Cool No Fan Common Problems Possible Cause Corrective Action Blown fuse or tripped circuit breaker Replace fuse or reset breaker Furnace power switch set to OFF Turn switch to ON Furnace blower compartment door or panel is loose Replace door panel in proper position to engage or not properly installed safety interlock or door switch No Heat or No Cool Possible Cause Corrective Action Thermostat may be in an Energy Wise
7. e is being programmed is highlighted Press or to adjust the Morning setpoint to the desired temperature Press to highlight the Day TOD Starts At time 7 Repeat Steps 5 6 for the Day Evening and Night Starts At and Heat To Cool To setpoints 8 When changes are complete press SAVE See 5a and 5b 9 If programming a 7 Day schedule repeat steps 5 8 for Tuesday through Sunday 10 Press HOME after programming is complete and changes have been saved Pepco Energy Wise Rewards Thermostat User s Manual 11 PROGRAMMING TIPS e If you don t want to program a particular day you can skip it Press NEXT one or more times until you reach the desired day e If you want to similarly program days in a group with only slight differences program as a group first then program individual days as needed The individual day program overrides the group program e While programming the heating or cooling schedule press the GO TO HEAT or GO TO COOL button choose for current schedule being programmed to save any changes made and display the program schedule for that mode of operation Step 4 Temporary Versus Permanent Hold A temporary hold can be set when operating in any mode except for OFF A temporary hold is set by pressing the or on the thermostat to adjust the desired temperature The SET AT indication of the temperature setpoint will change to HOLD AT and a message will be cycled in the thermostat messaging
8. ent On Recovery When complete press SAVE to see page 9 save settings or HOME to exit without saving EC F Use to change selection C When complete press SAVE to save settings or HOME to exit without saving Pepco Energy Wise Rewards Thermostat User s Manual 7 Step 2 Thermostat Main Menu and Other Settings C Description of Programming and Other Settings Menu Options The following are detailed descriptions of your Energy Wise Rewards thermostat configuration menu options 1 Programming Heat Cool Programming The Energy Wise Rewards thermostat can be programmed as a 7 day or 5 2 day thermostat Using a 7 day programming profile you can program each day of the week with its own individual setpoint profile With a 5 2 day programming profile Monday Friday each has the same setpoint profile while Saturday Sunday can be programmed with its own setpoint profile You can increase or decrease the temperature during the programming cycle if desired 2 Other Settings Backlight This menu item controls the display backlight You can choose either e AUTO Default Backlight comes on when you press any key Backlight goes off after a short delay when there is no button pressed e ON Backlight is always On 3 Other Settings Temperature Limits Temperature limits can be used to set limits on how high your heating temperature can be set and how low your cooling temperature can be set The range for both values
9. ithin a few seconds the thermostat should make a soft click sound This sound usually indicates the thermostat is operating properly If the thermostat does not click after being reset contact Pepco Energy Wise Rewards for a replacement thermostat If the thermostat does click contact the furnace manufacturer or your HVAC contractor for a service visit to verify the heating is operating correctly Furnace Air Conditioner Cycles Too Fast or Too Slow Narrow or Wide Temperature Swing Possible Cause Corrective Action The location of the thermostat and or the size of the heating system may be influencing the cycle rate Electronic thermostats like this one normally provide precise temperature control and may cycle faster than some older mechanical models A faster cycle rate means the unit turns on and off more frequently to maintain the desired temperature but runs for a shorter time so there is no increase in overall energy use 14 Pepco Energy Wise Rewards Thermostat User s Manual Troubleshooting No Cool Possible Cause Corrective Action System switch not set to COOL Press SYSTEM button to select COOL and press to lower the temperature setpoint below room temperature Outdoor unit disconnect or breaker tripped Verify the outdoor unit disconnect or breaker has not been tripped Cooling system requires service or thermostat To diagnose this condition requires replacement Press SYSTEM button to select COOL and pre
10. m 70 Sat Sun Day 8 00am 62 Use to raise lower values Evening 5 00pm 70 Night 10 00pm 62 When complete press SAVE to 7 Days save settings or GO TO COOL to program cool settings Cool Programming Mon Fri Default settings Use the to scroll through items to change Morning 6 00am 78 Sat Sun Day 8 00am 85 Use to increment Evening 5 00pm 78 decrement values Night 10 00pm 82 When complete press SAVE to save settings or GO TO HEAT to program heat settings 7 Days Keep Track of Your Thermostat Settings Below Weekdays Weekend Period HEAT MOR DAY EVE NGT COOL MOR DAY EVE NGT 6 Pepco Energy Wise Rewards Thermostat User s Manual Step 2 Thermostat Main Menu and Other Settings B Other Settings Press or to Menu Name Submenu Select Other Options Comments Defaults in BOLD Backlight Auto Use to change values Auto On On When complete press SAVE Temperature Limits Min Cool Set Point Use the to select setpoint 45 F to change Max Heat Set Point Use to raise lower value 99 F When complete press SAVE to save settings or HOME to exit without saving Adjust Current Room Temp Use to increment Temperature measured temp decrement value Display Desired Offset 0 When complete press SAVE to save settings or HOME to exit without saving Time Based Not Currently Used Programming Energy Off Use to change selection Managem
11. mperature Temperature e Blank when user selects the OFF mode via the menu turns system off e When system is ON the words SET AT changes to HOLD AT when in temporary or permanent hold FAN Status Blank when in auto mode displays FAN ON when fan is on continuously System Status Displays current operation mode according to system configuration as set by installer e OFF system is OFF e COOL system is in COOL mode but no call for cool call for first stage of cool call for second stage of cool multi stage units only e AUX system is in AUX heat mode but no call for heat heat pump only call for first stage of Auxiliary heat heat pump only call for second stage of Auxiliary heat multi stage heat pump only e HEAT system is in HEAT mode but no call for heat call for first stage of heat call for second stage of heat multi stage units only call for first stage of auxiliary heat heat pump only call for second stage of auxiliary heat multi stage heat pump only 6 Soft Key Display Actions to be performed when corresponding button is pressed 4 Pepco Energy Wise Rewards Thermostat User s Manual Step 2 User Main Menu and Other Settings A User Main Menu The User Programming Menu table next page summarizes the configuration items that the user can change and a convenient space to keep track of your settings For more details on each user programming menu option see Descripti
12. on of User and Other Settings Menu Options on page 8 To enter the User Programming Menu 1 Ensure the thermostat is at the idle screen display with the room temperature displaying 2 Press the MENU soft key The display will show the first level of the User Programming Menu 3 While in the User Programming Menu e The and scrolls the cursor up and down respectively e The soft key labeled HOME exits the User Programming Menu back to the IDLE screen NOTE when the HOME soft key is pressed any changes made on the current menu item are not saved The button selects the highlighted menu item e The BACK soft key goes back one menu level e When changes are made to a menu item the BACK soft key changes to SAVE Press SAVE once after making a change the screen goes back one menu level after a change is saved e f a mistake is made during programming press SAVE once then return to the programming option and re enter the information press SAVE again press HOME to exit 4 To exit the menu and return to the program operation press HOME when available If no keys are pressed within two minutes the thermostat will revert to normal operation Pepco Energy Wise Rewards Thermostat User s Manual 5 Thermostat Programming Menu Press or to Menu Name Submenu Select Other Options Comments Defaults in BOLD Heat Programming Mon Fri Default settings Use the to scroll through items to change Morning 6 00a
13. ss to lower the temperature setpoint below room temperature Within a few seconds the thermostat should make a soft click sound This sound usually indicates the thermostat is operating properly If the thermostat does not click after being reset contact your installing contractor for a replacement thermostat If the thermostat clicks contact the furnace manufacturer or HVAC contractor for a service visit to verify the cooling is operating correctly Multi stage Air Conditioner Heat Pump Second Third and or Fourth Stage Won t Come On Possible Cause Corrective Action Your thermostat is designed to determine the Wait for the second third and or fourth stage to optimum time to activate the second stage Simply come on raising the temperature in heating or lowering it in cooling will not always force the thermostat to bring the second stage on quickly There is a time delay from 0 30 minutes depending on the performance of the first stage of the system Pepco Energy Wise Rewards Thermostat User s Manual 15 PECS1214 KM 1M energy wise rewards 1 866 353 5798 pepco com rewards VA pepco
14. the thermostat will return to the HOME screen 3 Press or to highlight Heating Program or Cooling Program then press Action button 4 Press or to highlight Mon Fri Sat Sun or 7 Days then press Action button a Mon Fri sets all weekdays to the same operating schedule b Sat Sun sets the weekend days to the same operating schedule c 7 Days allows the user to program each day individually TLL NOTE If the EXIT key is pressed at any point while in the Time of Day TOD programming menu the thermostat will return to the previous menu If any changes are made to a TOD time period or setpoint the EXIT key label will change to SAVE 10 Pepco Energy Wise Rewards Thermostat User s Manual 5 The Morning TOD Starts At time is highlighted Press or to adjust the Morning TOD time period to the desired start time Press to highlight the Morning TOD setpoint a For Mon Fri or Sat Sun pressing SAVE will save the changes and return to the previous screen b For 7 Days pressing SAVE on days Monday through Saturday will advance the thermostat to the next day or Sunday it will save the settings and return to the previous menu NOTE If no changes are made there will not be a SAVE button The button will be e EXIT for Mon Fri Sat Sun and only on Sunday for 7 Days Re e NEXT for Monday through Saturday for 7 Days i 6 The Morning Heat To or Cool To depending on which mod
Download Pdf Manuals
Related Search
Related Contents
G Programming Reference Manual KLI Bedienungsanleitung KLI User manual BA IKS-GA,S v.07-04 Graustufen 03.05.04 USER'S MANUAL 3G3AX-PG Télécharger ces résumés en PDF Télécharger - Gilles Berhault Télécharger MIDI Solutions Breath Controller Samsung ML-6050 Manuel de l'utilisateur Forerunner® 220 - T Copyright © All rights reserved.