1. 4 2 Removing the air duct Remove the top cover as described in section Opening the server on page 17 Figure 4 Removing the air duct b Take out the air duct Econel 230R S1 Options Guide 19 5 Processors CAUTION Observe the safety instructions in the chapter Safety notes on page 11 et seq CAUTION Processors are components which are extremely sensitive to electro static discharges and must be handled with caution After taking a processor out of its protective wrapper set it on an insulated antistatic surface with the smooth side down Never slide a processor over a surface 5 1 Installing a second processor The system board can be upgraded with a second processor The upgrade kit includes a processor and a heat sink CAUTION You may only use processors of the same type on the system board The second processor must have the same type and clock rate as the first Use a suitable multiprocessor operating system if dual operation is required Remove the top cover as described in section Opening the server on page 17 Remove the air duct as described in section Removing the air duct on page 19 Econel 230R S1 Options Guide 21 Installing a second processor Processors Installing the processor E PA eee A LA Pr BEE Figure 5 Releasing the socket lever Release the socket lever by pressing it downward and
2. on page 17 et seq Figure 16 Removing a memory module gt Press the holders on either side of the mounting location concerned outward 1 30 Options Guide Econel 230R S1 Main memory Extending replacing the main memory gt Ifthe mounting location was already equipped pull the memory module out of the mounting location 2 Figure 17 Inserting a memory module gt Press the holders on either side of the mounting location concerned outward Insert the memory module in the mounting location 1 until the holders at the sides engage 2 Close the server connect it to the power outlet and switch it on as described in the chapter Completion on page 49 et seq Econel 230R S1 Options Guide 31 7 Accessible drives CAUTION Observe the safety instructions in the chapter Safety notes on page 11 et seq 7 1 Installing an accessible 5 25 inch drive One 5 25 inch bay is available for accessible drives The 5 25 inch drives available are DVD ROM DVD RW and tape drives These drives can be installed in the free 5 25 inch bay For installing a tape drive you need an additional SCSI controller because there is no onboard SCSI controller on the system board Open the server as described in the chapter Preparation on page 17et seq Figure 18 Removing the dummy cover gt Press the two locking levers of the dummy cover in direction of the
3. Expansion boards in the PCI slots Installing an expansion board Fasten the expansion board s rear cover with the screw gt f required connect the cables to the system board or other components Close the server connect it to the power outlet and switch it on as described in the chapter Completion on page 49 et seq Installing in PCI slots of the riser card Open the server as described in the chapter Preparation on page 17 et seq Remove all external cables being connected to installed expansion boards ARRE AAAH ALAN Figure 30 Pulling up the label gt Pull up the green handle of the riser card holder using the label Econel 230R S1 Options Guide 43 Installing an expansion board Expansion boards in the PCI slots Figure 31 Removing the riser card holder gt Take the riser card holder straight upward out of the housing using the green handle Please read the documentation supplied with the expansion board gt f necessary connect cables onto the expansion board 44 Options Guide Econel 230R S1 Expansion boards in the PCI slots Installing an expansion board Figure 32 Removing the rear cover Remove the screw and pull out the PCI slot s rear cover CAUTION Keep the rear cover of the PCI slot for future use If you remove the expansion board again and do not replace it with a new one the rear cover must be reinstalled
4. arrows and pull the dummy cover out of the bay CAUTION Keep the dummy cover for future use If you remove the accessible drive again and do not replace it with a new one the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling require ments and fire protection measures Econel 230R S1 Options Guide 33 Installing an accessible 5 25 inch drive Accessible drives gt Attach two guidance pins to the 5 25 inch drive You will find a sac with the guidance pins in the drive s bay Otherwise remove the guidance pins from the dummy cover Figure 19 Removing the guidance pins from the dummy cover gt For installing a tape drive install the SCSI controller in a PCI slot of the riser card as described in section Installing in PCI slots of the riser card on page 43 Figure 20 Routing SCSI cable Forinstalling a tape drive route the SCSI cable as shown in the photo 34 Options Guide Econel 230R S1 Accessible drives Installing an accessible 5 25 inch drive Figure 21 Unlocking the bay Pull up the locking lever of the bay gt Push the 5 25 inch drive into the bay until it is aligned to the server front side Econel 230R S1 Options Guide 35 Installing an accessible 5 25 inch drive Accessible drives Figure 22 Locking the bay Push down the locking lever of the bay until it engages gt Connect th
5. gt Position the top cover in such a way that it protrudes approxiate 2 cm at the rear gt Push the top cover all the way in direction to the front side Fasten the top cover with the knurled screw 50 Options Guide Econel 230R S1 Completion Closing the server If you have not removed the server from the rack cabinet please skip this page gt Push the server from the front side in the extended telescopic rails Reconnect all the cables you disconnected beforehand on the rear of the server Figure 37 Installing the server in a rack cabinet Press in the safety springs 1 on both sides and push the server as far as it will go into the rack Fasten the server in the rack using the two knurled screws 2 Connect all power plugs to the safety sockets Press the on off button to start up the server Econel 230R S1 Options Guide 51 11 Appendix 11 1 Cabling The following table gives you an overview of the cables Cable Part number Item number Designation Length no 1 A3C40085575 SATA cable SATA 6 580 mm black black A3C40085575 SATA cable SATA 5 blue blue 580 mm A3C40085575 SATA cable SATA 4 580 mm orange orange 4 A3C40085588 SATA cable SATA 3 320 mm green blue 5 A3C40085588 SATA cable SATA 2 red black 320 mm A3C40085588 SATA cable SATA 1 320 mm yellow orange 7 A3C40085681 Backp
6. interleaved mode Additional accessible drive One 5 25 inch bay is available for accessible drives Additional non hot plug hard disk module only non hot plug variant Up to six non hot plug hard disk modules can be installed Expansion boards in the PCI slots The system board offers 1x PCI Express x8 slot Additional the following slots are available by a riser card 1xPCI Express x8 slot 1 x PCI Express x4 slot and 1 x PCI X 64 Bit 66 MHz ZCR slot Econel 230R S1 Options Guide 7 Notational conventions Introduction 1 3 Notational conventions The following notational conventions are used in this manual Text in italics indicates commands menu items or software programs Quotation marks indicate names of chapters and terms that are being emphasized gt describes activities that must be performed in the order shown CAUTION pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data i indicates additional information notes and tips 8 Options Guide Econel 230R S1 2 Procedure CAUTION e The actions described in this manual should only be performed by technical specialists e Equipment repairs should only be performed by service personnel e Any unauthorized opening and improper repairs could expose the user to risks electric shock energy haza
7. mechanical damage and damage to the CD DVD drive as well as premature CD DVD wear by observing the following sugges tions e Only insert CDs DVDs in the drive when needed and remove them after use e Store the CDs DVDs in suitable sleeves e Protect the CDs DVDs from exposure to heat and direct sunlight 14 Options Guide Econel 230R S1 Safety notes Laser information The CD DVD drive complies with IEC 60825 1 laser class 1 CAUTION The CD DVD drive contains a light emitting diode LED which under certain circumstances produces a laser beam stronger than laser class 1 Looking directly at this beam is dangerous Never remove parts of the CD DVD drive casing Modules with electrostatic sensitive components Systems and components that might be damaged by electrostatic discharge ESD are marked with the following label A Ata When you hanale components fitted with ESDs you must observe the following points under all circumstances Figure 1 ESD label e Remove the power plug before installing or removing components containing ESDs e You must always discharge yourself of static charges e g by touching a grounded object before working e The equipment and tools you use must be free of static charges e Only touch the components at the positions highlighted in green touch points e Do not touch any exposed pins or conductors on a component e Use a grounding cable designed for this p
8. the ServerBooks DVD the Software CD and the update CDs for Windows and Linux The PDF version of the manual PRIMERGY ServerView Suite ServerStart is also available on the ServerBooks DVD If you need a backup of the ServerBooks DVD send the details of your server via email address Reklamat PC LOG fujitsu siemens com LSI SATA Software RAID User s Guide PDF file available on the ServerBooks DVD Further sources of information Technical Manual on the relevant rack Manual on the monitor Manual on ServerView Server Management Manual on RemoteView Remote Server Maintenance Documentation on boards and drives Documentation on your operating system Information files on your operating system see also Related publications on page 63 6 Options Guide Econel 230R S1 Introduction Extensions and conversions 1 2 Extensions and conversions Second processor The server can be upgraded to a so called dual processor system A dual processor system needs a multi processor operating system The second processor must have the same type and clock rate as the first Extension of the main memory Eight slots 4 banks with 2 modules are available for the main memory Each memory bank can be populated with 512 Mbyte 1 Gbyte 2 Gbyte or 4 Gbyte ECC DDR 2 SDRAM memory modules If the memory modules are populated in pairs each pair must consist of identical memory modules 2 way
9. to comply with EMC regulations and to satisfy cooling requirements and fire protection measures Econel 230R S1 Options Guide 45 Installing an expansion board Expansion boards in the PCI slots Figure 33 Installing the expansion board Install the expansion board in the PCI slot of the riser card Make sure that the rear ofthe expansion board s slot cover is positioned in the intended recess Fasten the expansion board s slot cover with the screw 46 Options Guide Econel 230R S1 Expansion boards in the PCI slots Installing an expansion board ce hen aaa pa yo paa 7 Figure 34 Installing the riser card holder gt Insert the riser card holder into the guidances right side and recesses left side of the chassis gt Push the riser card into the PCI slot of the system board gt f required connect the cables to the system board or other components Close the server connect it to the power outlet and switch it on as described in the chapter Completion on page 49 et seq Econel 230R S1 Options Guide 47 10 Completion CAUTION Observe the safety instructions in the chapter Safety notes on page 11 et seq 10 1 Inserting the air duct Figure 35 Inserting the air duct gt Insert the air duct Econel 230R S1 Options Guide 49 Closing the server Completion 10 2 Closing the server Figure 36 Attaching the top cover
10. Emergency Management Port EPP Enhanced Parallel Port ESD ElectroStatic Discharge FPC Front Panel Controller FRU Field Replaceable Unit FSB Front Side Bus 58 Options Guide Econel 230R S1 Abbreviations GAM Global Array Manager GUI Graphical User Interface HDD Hard Disk Drive HSC Hot Swap Controller 12C Inter Integrated Circuit 1 0 Input Output ICM Intelligent Chassis Management ID Identification IDE Integrated Drive Electronics IOOP Intelligent Organization of PCI iRMC integrated Remote Management Controller IRQ Interrupt Request Line LAN Local Area Network LBA Logical Block Address Econel 230R S1 Options Guide 59 Abbreviations LCD Liquid Crystal Display LUN Logical Unit Number LVD Low Voltage Differential SCSI MMF Multi Mode Faser MRL Manually Retention Latch NMI Non Maskable Interrupt NVRAM Non Volatile Random Access Memory OS Operating System PCI Peripheral Component Interconnect PDA Prefailure Detection and Analysing POST Power ON Self Test RAID Redundant Arrays of Independent Disks RAM Random Access Memory ROM Read Only Memory 60 Options Guide Econel 230R S1 Abbreviations RSB Remote Service Board RTC Real Time Clock RTDS Remote Test und Diagnose System SAF TE SCSI Accessed Fault Tolerance Enclosures SAS Serial Attached SCSI SATA Serial ATA SBE Single Bit Error SCA Single Connector At
11. PRIMERGY Econel 230R S1 Server Options Guide Edition May 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Feel free to send us your comments by e mail to manuals fujtsu siemens com Certified documentation according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft f r Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright O 2007 Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers Contents 1 1 1 2 1 3 4 1 4 2 5 1 6 1 6 2 7 1 introductio 2 ira a aba 5 Overview of the documentation 5 Extensions and conversions 7 Notational conventions 8 PrOGCOLQUEFO uu 20 n m eRe ad 9 Dae NOES oa a Us dedero uis ded 11 Preparation 222m xkcG dE RERO REG ERRARE 17 Opening the Server 17 Removing the air duct 19 PIODOSSOFB cia A ox Rue e
12. afety notes CAUTION Make sure that no objects such as bracelets or paper clips fall into or liquids spill into the device risc of electric shock or short circuit In emergencies e g damaged casing controls or cables penetration of liquids or foreign matter switch off the device immediately remove the power plug from the safety socket and contact your sales outlet or customer service team Proper operation of the device in accordance with IEC 60950 1 EN 60950 1 is only ensured if the casing is completely assembled and the rear covers for the installation openings have been put in place electric shock cooling fire protection interference suppression Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment If you install other expan sions you may damage the system or violate the safety regulations and regulations governing RFI suppression Information on which System expansions are suitable can be obtained from the customer service centre or your sales outlet The components or parts marked with a warning label e g lightning symbol may only be opened removed or exchanged by authorized qualified personnel The warranty expires if the device is damaged during the installation or replacement of system expansions You may only set those resolutions and refresh rates specified in the operating
13. e data cable to the 5 25 inch drive see the cabling plans in the Appendix gt Connect the power cable to the 5 25 inch drive see the cabling plans in the Appendix gt Close the server connect it to the power outlet and switch it on as described in the chapter Completion on page 49 et seq 36 Options Guide Econel 230R S1 8 Non hot plug hard disk modules CAUTION Observe the safety instructions in the chapter Safety notes on page 11 et seq 8 1 Installing non hot plug hard disk modules Remove the top cover as described in section Opening the server on page 17 Figure 23 Removing the cables Remove the plugs of the SATA cables from the already installed hard disk modules Remove the plug of the power adapter cable from the power cable Econel 230R S1 Options Guide 37 Installing non hot plug hard disk modules Non hot plug hard disk modules Figure 24 Removing the hard disk modules and the dummy cover Remove the hard disk modules and the dummy cover together from the bay Therefore press the two locking levers of the hard disk module dummy cover in direction of the arrows and pull the hard disk module dummy cover out of the bay The hard disk modules are connected by the power adapter cable see figure 25 on page 39 gt Replace the dummy cover by a hard disk module CAUTION Keep the dummy cover for future use If you remove the hard disk
14. lane I2C cable left side 380 mm 8 A3C40085657 Backplane I C cable right side 730 mm 9 A3C40085686 IDtemp cable 10 A3C40085684 CD DVD ROM cable 11 A3C40085685 USB cable 12 A3C40085682 Front panel cable 13 A3C40085683 Fan extension cable 14 A3C40085687 Intrusion switch cable 300 mm refers to the drawings of the cabling Econel 230R S1 Options Guide 53 Cabling Appendix Cs D D T Standard PSU Figure 38 Cabling non hot plug 54 Options Guide Econel 230R S1 Appendix Cabling Standard PSU w Backplane Figure 39 Cabling hot plug Econel 230R S1 Options Guide 55 Abbreviations AC Alternating Current ANSI American National Standard Institute ASR amp R Automatic Server Reconfiguration and Restart BIOS Basic Input Output System BMC Baseboard Management Controller cc Cache Coherency CD Compact Disk CD ROM Compact Disk Read Only Memory CHS Cylinder Head Sector CMOS Complementary Metal Oxide Semiconductor COM Communication CPU Central Processing Unit DC Direct Current Econel 230R S1 Options Guide 57 Abbreviations DIMM Dual Inline Memory Module DIP Dual Inline Package DMA Direct Memory Access DMI Desktop Management Interface ECC Error Checking and Correcting ECP Extended Capabilities Port EEPROM Electrically Erasable Programmable Read Only Memory EMC ElectroMagnetic Compatibility EMP
15. line documentation available on the Internet can be found using the URL http manuals fujitsu siemens com The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option Concept and target groups This Options Guide shows you how to extend and upgrade your server CAUTION The activities described in this manual may only be performed by technical specialists The installation and removal of the hot plug components is described in the Operating Manual supplied with the server Additional documentation about the server The PRIMERGY Econel 230R S1 documentation comprises the following additional manuals Safety notes and other important information print version delivered together with the system PDF file available on the ServerBooks DVD Warranty print version delivered together with the system PDF file available on the ServerBooks DVD Ergonomics PDF file available on the ServerBooks DVD Returning used devices PDF file available on the ServerBooks DVD Econel 230R S1 Server Operating Manual PDF file available on the ServerBooks DVD Econel 230R S1 Options Guide 5 Overview of the documentation Introduction Technical Manual for the system board D2440 PDF file available on the ServerBooks DVD BIOS Setup manual PDF file available on the ServerBooks DVD PRIMERGY ServerView Suite includes the ServerStart Disc 1 and 2
16. llation User Manual Econel 230R S1 Options Guide 63 Related Publications 12 13 14 15 16 17 18 19 20 21 22 PRIMERGY ServerView Suite ServerView S2 Server management User Manual PRIMERGY ServerView Suite ServerView Server management User Manual PRIMERGY ServerView Suite RemoteView User Manual PRIMERGY ServerView Suite integrated Remote Management Controller iRMC ServerView RAID User Manual Integrated RAID for SAS User s Guide LSI SATA Software RAID User Manual Integrated Mirroring User s Guide PRIMECENTER Rack Technical Manual DataCenter Rack Technical Manual 19 Rack Technical Manual 64 Options Guide Econel 230R S1 Index A S accessible drives 7 33 SATA hard disk drives air duct 19 49 T C target group 5 cabling hot plug 55 top cover 18 50 cabling non hot plug 54 D dual operation 21 E ESD devices sensitive to electrostatic discharge 15 expansion board 7 41 H heatsink 24 information material 6 L laser information 15 light emitting diode LED 15 lithium battery 14 M main memory 7 29 meaning ofthe symbols 8 multiprocessor operating system 21 N non hot plug hard disk module 37 notational conventions 8 P processor 7 heat sink 24 R riser card 41 Econel 230R S1 Options Guide 65 co FUJITSU Information on this document On April 1 2009 Fujitsu became the sole ow
17. lling a second processor a Figure 11 Installing the heat sink gt Place the heat sink onto the processor socket as shown in the figure Otherwise it is not possible to insert the air duct in the right way Figure 12 Hooking the clamp at the right side gt Setthe clamp on the heat sink and hook it on the distance holder at the right side Econel 230R S1 Options Guide 25 Installing a second processor Processors Figure 18 Hooking the clamp at the left side gt Hook the clamp on the distance holder at the left side 26 Options Guide Econel 230R S1 Processors Installing a second processor gt Press the two springs of the locking lever first somewhat outside and then downward until they engage CAUTION Never operate a processor without heat sink or without processor fan as otherwise the processor may overheat and fail causing the complete system board to fail Install the air duct as described in section Inserting the air duct on page 49 Close the server connect it to the mains and switch it on as described in section Closing the server on page 50 et seq Econel 230R S1 Options Guide 27 6 Main memory CAUTION Observe the safety instructions in the chapter Safety notes on page 11 et seq The system board supports up to 32 Gbytes of main memory Eight slots 4 banks with 2 modules are available for the main memo
18. manual of the monitor Otherwise you may damage your monitor If you are in any doubt contact your sales outlet or customer service centre Econel 230R S1 Options Guide 13 Safety notes Batteries CAUTION e Incorrect replacement of batteries may lead to a risk of explosion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer see the technical manual for the system board under Related publications on page 63 e Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board see Related publications on page 63 Working with CDs DVDs and CD DVD drives When working with devices with CD DVD drives these instructions must be followed CAUTION e Only use CDs DVDs that are in perfect condition in your server s CD DVD drive in order to prevent data loss equipment damage and injury e Check each CD DVD for damage cracks breakages etc before inserting it in the drive Note that any additional labels applied may change the mechanical properties of a CD DVD and cause imbalance Damaged and imbalanced CDs DVDs can break at high drive speeds data loss Under certain circumstances sharp CD DVD fragments can pierce the cover of the CD DVD drive equipment damage and can fly out of the device danger of injury particularly to uncovered body parts such as the face or neck You can prevent
19. module again and do not replace it with a new one the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling require ments and fire protection measures 38 Options Guide Econel 230R S1 Non hot plug hard disk modules Installing non hot plug hard disk modules Figure 25 Connecting the power adapter cable Connect the plugs of the power adapter cable to the hard disk modules The lowest power plug remains disconnected if only two hard disk modules will be installed Econel 230R S1 Options Guide 39 Installing non hot plug hard disk modules Non hot plug hard disk modules Figure 26 Inserting the hard disk modules Push the hard disk modules together into the bay until they engage Connect the plugs of the SATA cables to the hard disk modules see the cabling plans in the Appendix If only two hard disk modules will be installed the black respectively the red SATA plug remains disconnected color of the SATA plug color of the SATA plug position hard disk front left side front right side module top orange SAS1 orange SAS4 middle blue SAS2 blue SAS5 bottom black SAS3 black SAS6 Connect the plug of the power adapter cable to the power cable see figure 23 on page 37 Close the server connect it to the mains and switch it on as described in section Closing the server on page 50 et seq 40 Options G
20. n set up the device contact your sales outlet or our customer service team CAUTION e The actions described in this manual should only be performed by technical specialists e Equipment repairs should only be performed by service personnel e Any unauthorized opening and improper repairs could expose the user to risks electric shock energy hazards fire hazards and could also damage the equipment e Any unauthorized opening of the device will result in the invalidation ofthe warranty and exclusion from all liability Before starting up CAUTION e During installation and before operating the device observe the instructions on environmental conditions for your device e If the device is brought in from a cold environment condensation may form both inside and on the outside of the device Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up Material damage may be caused to the device if this requirement is not observed e Transport the device only in the original packaging or in packaging that protects it from knocks and jolts Econel 230R S1 Options Guide 11 Safety notes Installation and operation CAUTION If the device is integrated in an installation that receives power from an industrial public power supply network with the IEC309 connector the public power supply protection must comply with the requirements for the non industrial public power suppl
21. ner of Fujitsu Siemens Compu ters This new subsidiary of Fujitsu has been renamed Fujitsu Technology So lutions This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions Contact and support addresses will now be offered by Fujitsu Technology So lutions and have the format Ots fujitsu com The Internet pages of Fujitsu Technology Solutions are available at http ts fujitsu com and the user documentation at hrtp manuals ts fujitsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu Ubergegangen Diese neue Tochtergesellschaft von Fujitsu tragt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor l ngerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion Bitte beachten Sie dass alle Firmenbez ge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions bergegangen sind Kontakt und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form ts fujitsu com Die Internetseiten von Fujitsu Technology Solutions finden Sie
22. pull it upward until it stops SOM I Tata e 1 J i d 3 c mi ib cin m a Pees Figure 6 Removing the protection cover gt Remove the protection cover 22 Options Guide Econel 230R S1 Processors Installing a second processor y E pali i n ph pening the processor holder Figure 7 O gt Open the processor holder Take out the processor from its protective wrapper Ow TTTT PEGEL NG PATATATAS KU Figure 8 Inserting the processor Position the new processor over the socket and insert it carefully into the socket CAUTION The processor can only be installed in one particular direction Pay attention to the location mark on one of the corners and the recesses at the sides Do not use force to press it into the socket to avoid damaging the pins or the processor Econel 230R S1 Options Guide 23 Installing a second processor Processors 2 0eee A at SS un TP Pi Figure 9 Closing the processor holder Close the processor holder GE IIII MZ A Di SE ii Hal P EEL ng the socket lever o L4 Figure 10 Locki gt Lock the processor into place in the socket by placing the socket lever in its original position Installing the heat sink Remove the protective cover on the underside of the heat sink 24 Options Guide Econel 230R S1 Processors Insta
23. rds fire hazards and could also damage the equipment e Any unauthorized opening of the device will result in the invalidation ofthe warranty and exclusion from all liability First of all please familiarize yourself with the safety instructions in the section chapter Safety notes on page 11 et seq gt Ensure that all required manuals see Additional documentation about the server on page 5 are available printing out the PDF files if necessary You will definitely need the Operating Manual for the server and the Technical Manual for the system board Shut down the server correctly switch it off pull out the power plug s and open the server as described in the chapter Preparation on page 17 et seq gt Extend or upgrade your server as described in the relevant chapter The Operating Manual for the server describes how you install remove the hot plug components Close the server connect it to the power outlet and switch it on as described in the chapter Completion on page 49 et seq Start the operating system and if necessary configure it as required see the Operating Manual Econel 230R S1 Options Guide 9 3 Safety notes The following safety instructions are also provided in the manual Safety notes and other important information This device complies with the relevant safety regulations for data processing equipment If you have any questions about where you ca
24. ry Each memory bank can be populated with 512 Mbyte 1 Gbyte 2 Gbyte or 4 Gbyte ECC DDR 2 SDRAM memory modules 6 1 Equipping rules nm DIMM1B zn mj DIMMTA co CPU 2 oy DIMM2B Eu nm DIMM2A cn Tj DIMMAA emn Tj DIMM4B cn Dj DIMM3A cmn CPU 1 oj DIMM3B cmn Figure 15 Structure of the main memory Ifthe memory modules are populated in pairs each pair must consist of identical memory modules 2 way interleaved mode The module capacity between pairs can differ pair 2A 2B can be populated with two 512 Mbyte modules and pair 1A 1B with two 1 Gbyte modules CPU 2 must be installed to access DIMM3A 3B and DIMM4A 4B Econel 230R S1 Options Guide 29 Extending replacing the main memory Main memory The table below shows the order in which the memory banks must be populated DIMM DIMM DIMM DIMM 2A 2B 1A 1B 2 empty empty popu popu DIMMs lated lated 4 popu popu popu popu DIMMs lated lated lated lated CPU 1 DIMM DIMM DIMM DIMM DIMM DIMM DIMM DIMM 2A 2B 1A 1B 4A 4B 3A 3B 4 empty empty popu popu empty empty popu popu DIMMs lated lated lated lated 8 popu popu popu popu popu popu popu popu DIMMs lated lated lated lated lated lated lated lated CPU 1 CPU 2 6 2 Extending replacing the main memory Open the server as described in the chapter Preparation
25. tachment SCSI Small Computer System Interface SDDC Single Device Data Correction SDR Sensor Data Record SDRAM Synchronous Dynamic Random Access Memory SEL System Event Log SMI System Management Interrupt Econel 230R S1 Options Guide 61 Abbreviations SSU System Setup Utility SVGA Super Video Graphics Adapter USB Universal Serial Bus VGA Video Graphics Adapter 62 Options Guide Econel 230R S1 Related publications il 1 2 3 4 5 6 7 8 9 10 11 PRIMERGY manuals are available in PDF format on the ServerBooks DVD The ServerBooks DVD is part of the ServerStart Suite supplied with every server The PDF files of the manuals can also be downloaded free of charge from the Internet The overview page showing the online documentation available on the Internet can be found using the URL http manuals fujitsu siemens com The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option Safety notes and other important information Warranty Ergonomics Returning used devices PRIMERGY Econel 230R S1 Server Operating Manual System Board D2440 for Econel 230R S1 Technical Manual BIOS Setup Reference Manual Quick Start Hardware PRIMERGY Econel 230R S1 Poster Quick Start Software Quick Installation Guide Poster PRIMERGY ServerView Suite ServerStart User Manual PRIMERGY ServerView Suite ServerView Insta
26. uide Econel 230R S1 9 Expansion boards in the PCI slots CAUTION Observe the safety instructions in the chapter Safety notes on page 11 et seq The system board offers 1x PCI Express x8 slot Additional the following slots are available by a riser card 1xPCI Express x8 slot 1 x PCI Express x4 slot and 1 x PCI X 64 Bit 66 MHz ZCR slot 9 1 Installing an expansion board Installing in PCI Express x8 slot of the system board Open the server as described in the chapter Preparation on page 17 et seq gt Please read the documentation supplied with the expansion board gt f necessary connect cables onto the expansion board Remove the screw Econel 230R S1 Options Guide 41 Installing an expansion board Expansion boards in the PCI slots Figure 28 Removing the PCI slot s rear cover Remove the PCI slot s rear cover CAUTION Keep the rear cover of the PCI slot for future use If you remove the expansion board again and do not replace it with a new one the rear cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures GE P Figure 29 Removing the PCI slot s rear cover Install the expansion board in the PCI slot of the system board Make sure that the rear of the expansion board s slot cover is positioned in the intended recess 42 Options Guide Econel 230R S1
27. unter http de ts fujitsu com und unter Attp manuals ts fujitsu com finden Sie die Benutzerdokumentation Copyright Fujitsu Technology Solutions 2009
28. urpose to connect yourself to the system unit as you install components Econel 230R S1 Options Guide 15 Safety notes e Place all components on a static safe base You will find a detailed description for handling ESD components in the relevant European or international standards DIN EN 61340 5 1 ANSI ESD S20 20 16 Options Guide Econel 230R S1 4 Preparation CAUTION Observe the safety instructions in the chapter Safety notes on page 11 et seq 4 1 Opening the server gt Terminate all applications and shut down the server correctly gt If your operating system has not switched off the server press the on off button gt Pull all power connectors out of the safety sockets gt Disconnect all cables on the rear of the server Figure 2 Pulling the server out of the rack gt Loosen the two knurled screws 1 and pull the server as far as possible out of the rack Push the safety springs 2 on both sides and carefully pull the server outward gt Pull the server out of the rails and place it on a table for example Econel 230R S1 Options Guide 17 Opening the server Preparation Figure 3 Loosening the screws Unlock the top cover by removing the knurled screw at the rear side gt Pull the top cover approxiate 2 cm frontward using the handle Remove the top cover 18 Options Guide Econel 230R S1 Preparation Removing the air duct
29. we 21 Installing a Second processor 21 A c unco mre eee eee ec Sears x 29 EQUIPPING PII S iuro reiben 29 Extending replacing the main memory 30 Accessible drives 33 Installing an accessible 5 25 inch drive 33 Econel 230R S1 Options Guide Contents 8 Non hot plug hard disk modules 37 8 1 Installing non hot plug hard disk modules 37 9 Expansion boards in the PCI slots 41 9 1 Installing an expansion board 41 10 Completion isa aaa h Rh RR KA eee dw 49 10 1 Inserting the aif duct 2 5 rok ecos 49 10 2 Closing the Server netid tada 50 11 ADDOROIX sa GNG or a OY ROSE x 53 11 1 Gabing rica 53 AbDIGULIMIDIS sod AG REA od PEE XR RR HARANGAN RS 57 Related publications ee nn 63 lol irre EGG HERES SES SSE TA 65 Options Guide Econel 230R S1 1 Introduction The PRIMERGY Econel 230R S1 server is an AMD based server for small and medium sized networks The PRIMERGY Econel 230R S1 is the perfect choice for operational areas data centers Internet and application hosting 1 1 Overview of the documentation PRIMERGY manuals are available in PDF format on the ServerBooks DVD The ServerBooks DVD is part of the ServerStart Suite supplied with every server The PDF files of the manuals can also be downloaded free of charge from the Internet The overview page showing the on
30. y networks for the type A connector The device automatically sets itself to a voltage in the range of 100 V 127 V oder 200 V 240 V Make sure that your local voltage is within this range This device has a specially approved power cable and must only be connected to a safety socket on the rack mains socket strip The ON OFF button does not disconnect the device from the mains voltage To completely disconnect it from the mains voltage remove the power plug from the safety socket Always connect the device and the attached peripherals to the same power circuit Otherwise you run the risk of losing data if for example the server is still operating but the peripheral device e g storage subsystem has failed during a power outage Take notice that the data cables to peripheral devices are adequately shielded To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174 1 2 As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Route the cables in such a way that they do not form a potential hazard and that they cannot be damaged When connecting up a device refer to the relevant notes in this manual Never connect or disconnect data transmission lines during a storm lightning hazard Options Guide Econel 230R S1 S