Home
Q68DAV,Q68DAI D/A Converter Module User`s Manual(Hardware)
Contents
1. 0 39 A 5 V DC 2 8 ron Bri on a IN 24voc Name RUN LED Displays the operating status of the D A converter module On Normal operation Flashing During offset gain setting mode Off 5V power supply interrupted or watch dog timer error E Number 2 ERROR LED Displays the error status of the D A converter module On Error Off Normal operation Flashing Error in switch settings a a Switch No 5 of the intelligent function module has been set to a value other than 0 xternal power supply This is the terminal for connecting the 24 V DC external power terminal ly 4 Handling Precautions 1 Do not drop the module or cause it to receive strong impact 2 Tighten the terminal screws for the module to the specified torque shown below Insufficient tightening torque could result in shorts failures or malfunction crew location g g q Module mounting screw M3 screw 36 to 48 N cm Terminal block terminal screw M3 screw 42 to 58N cm Terminal block mounting screw M3 5 screw 66 to 89 N cm FG terminal screw M3 screw 42 to 58 N cm 5 Wiring 5 1 Wiring precautions 1 Use separate cables for the external output signal or external power supply for the AC and D A converter modules Take steps to prevent the AC side from being affected by surge or inductance 2 Ground one point of the shield for shielded wires or sh
2. to 16383 12287 Analog output 10 to 10V DC External load 0 to 20 mA DC External load resistance 1kQ to1MQ resistance 0 Q to 600 Q VO characteristics Analog output range maximum resolution Oto5V 1to5V 10to Users 0 to 20 mA 4 to 20 mA Users 10V range range setting setting value ae oe eee e resolution value o 16000 to 12000 to 12000 resolution mV mV Ambient Accuracy in temperature respect to 25 5 C maximum Ambient analog output temperature value 0 to 55 80 u s channel Within 0 1 Voltage 10mV Current 201A Within 0 3 Voltage 30mV Current 601A eg oe a Absolute maximum output Output short circuit protection Available Insulation method Between I O terminal and PLC power supply Photocoupler insulation Between output channels Not insulated Between external supply power and analog output_ Not insulated lumber of occupied points 16 points FG terminal R1 25 3 1 25 YS3 RAV1 25 3 V1 25 YS3A 0 18 kg 24VDC 20 15 3 Part Names 18 points terminal block Ripple spike within 500 mVP P This section explains the names of the components for the D A converter module pplicable wire size 0 3 to 0 75 mm Applicable solderless terminals Other terminals than FG R1 25 3 Inrush current 3 3A within 70us 0 19A Cc z a Na Terminal Signal name soe Q68DAV Q68DAI A solderless terminals with sleeves cannot be used Internal current consumption
3. 6100 SINGAPORE 159943 min 4 Tel 65 473 2480 Italy wneu pishi Electric Europe B V Italian Thailand F A Tech Co Ltd Centro Dir Colleoni Pal Perseo Ingr 2 898 28 29 30 S V City Building Office Via Paracelso 12 20041 Agrate B Tower 2 Floor 17 18 Rama 3 Road Milano Italy Bangkpongpang Yannawa Tel 39 039 6053301 Bangkok 10120 Spain Mitsubishi Electric Europe B V Spanish Tel 66 2 682 6522 South Africa MSA Manufacturing Pty Ltd Hong Kong Ryoden International Ltd Australia Branch Indonesia P T Autoteknindo SUMBER MAKMUR Pol Ind Can Magi C Joan Buscalla JI Muara Karang Selatan Block A Utara 2 4 A C 420 No 1 Kav No 11 Kawasan Industri 08190 Sant Cugat del Valles Barcelona Pergudangan Jakarta Utara 14440 Spain Tel 62 21 663 0833 Tel 34 935 653135 India Messung Systems Put Ltd Electronic Sadan NO 111 Unit No15 M 1 D C BHOSARI PUNE 41 1026 Tel 91 20 7128927 Mitsubishi Electric Australia Pty Ltd 348 Victoria Road PostalBag No 2 Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE MITSUBISHI DENKI BLDG MARUNOUCH TOKYO 100 8310 TELEX J24532 CABLE MELCO TOKYO NAGOYA WORKS 1 14 YADA MINAMI 5 HIGASHI KU NAGOYA JAPAN P O Box 39733 Bramley 201 8 Johannesburg South Africa Tel 27 11 444 8080 10th Floor Manulife Tower 169 Electric Road North Point HongKong Tel 852 2887 8870 When exported from Japan this manual does not require applica
4. MC Directive and Low Voltage Instruction When complying with EMC Directives and Low Voltage Directives by assembling a Mitsubishi PLC compatible with EMC Directive and Low Voltage Directives into the user product refer to Chapter 3 EMC Directives and Low Voltage Directives in the User s Manual Hardware Section for the CPU module being used The CE logo is printed on the rating plate on the main body of the PLC that conforms to the EMC directive and low voltage instruction 1 Overview This manual explains specifications and the names of the components for the Q68DAV type D A converter module hereafter Q68DAV and the Q68DAI type D A converter module hereafter Q68DAI which are used in combination with the MELSEC Q Series CPU module In this manual both the Q68DAV and Q68DAI are referred to as D A converter modules After unpacking confirm that the following products are enclosed Po Patname ty Q68DAV Q68DAI Model Digital Analog module FG terminal L shaped metal fitting 2 Specifications The specifications for the D A converter module are shown in the following table For general specifications refer to the operation manual for the CPU module being used Se o o umber of analog outputs 8 points 8 channels Digital input 16 bit signed binary normal resolution 16 bit signed binary normal mode 4096 to 4095 resolution mode 4096 to 4095 high resolution mode 12288 to high resolution mode 12288 to 12287 16384
5. MITSUBISHI Q68DAV Q68DAl D A Converter Module Thank you for buying the Mitsubishi general purpose programmable logic controller MELSEC Q Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product User s Manual MELSEG Q Hardware Mitsubishi Programmable ope Logic Controller IB 0800151 A 0012 MEE MODEL Q 68D A U H JE 2000 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS Read these precautions before using When using Mitsubishi equipment thoroughly read this manual and the associated manuals introduced in the manual Also pay careful attention to safety and handle the module properly These precautions apply only to Mitsubishi equipment Refer to the user s manual of the CPU module to use for a description of the PLC system safety precautions These SAFETY PRECAUTIONS classify the safety precautions into two categories DANGER and CAUTION Procedures which may lead to a dangerous condition and DANGER cause death or serious injury if not carried out properly 1 1 I I I I i Procedures which may lead to a dangerous condition and i Z CAUTION cause superficial to medium injury or physical damage only 1 i if not carried out properly Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Store this man
6. ation power generation aerospace medical or passenger transport applications consult our sales representatives e This product is manufactured under our strict quality control system However if the product is used in the intended facility in such a way that a failure of the product may lead to serious accident or loss incorporate backup or fail safe functions into the system design Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc China Brazil MELCO TEC Rep Com e Assessoria Germany Mitsubishi Electric Europe B V German Korea Country Region Sales office Tel Ryoden International Shanghai Ltd 500 Corporate Woods Parkway Vernon 3F Block5 Building Automation Hills IL 60061 Instrumentation Plaza 103 Cao Bao Rd Tol 1 847 478 2100 Shanghai 200233 China Tel 86 21 6475 3228 Av Rio Branco 123 15 and S 1507 Taiwan Setsuyo Enterprise Co Ltd Rio de Janeiro RJ CEP 20040 005 6F No 105 Wu Kung 3rd RD Wu Ku Brazil Hsiang Taipei Hsine Taiwan R O C Tel 55 21 221 8343 Tel 886 2 2299 2499 HAN NEUNG TECHNO CO LTD Branch 1F Dong Seo Game Channel Bldg Gothaer Strasse 8 D 40880 Ratingen 660 11 Deungchon dong Kangsec ku GERMANY Seoul Korea Tel 49 2102 486 0 Tel 82 2 3668 6567 Tecnica Ltda UK Mitsu pent EBOMI EUTOPS BV UK Singapore Mitsubishi Electric Asia Pte Ltd gt 307 ALEXANDRA ROAD 05 01 02 Jravalters Lae Hallie Hers AC10 MITSUBISHI ELECTRIC BUILDING Tel 44 1707 27
7. ielded cables If it is di d metal fitting 5 2 External wiring 1 Q68DAV D A A conversion 15 V DC DC J converter A G 15V Filter 2 Q68DAI i 2 Motor drive module etc D A ow conversionl to 600W DC DC converter Filter 1 Use a twisted two core shielded wire for the power wire 2 If there is noise or ripples in the external wiring connect a 0 1 to 0 47 m F25V condenser between the V l terminal and COM 5 3 Switch setting for intelligent functional module The settings for the intelligent function module are performed using the I O allocation settings for the GX Developer It can be easy to set by inputting using hexadecimal 4 digits Output range settin CHA to CHA 9 Analog output range Output range setting value HOU CH4 CH3 CH2 CH1 Switch 2 Output range setting CH 5 to CH 8 OOOO s CH8 CH7 CH6 CH5 Switch 3 2 4 b8 b7 b6 b5 b4 b3 b2 bi bO HOLD CLEAR function setting MIOOUUUUU fow CH8 CH7 CH6 CH5 CH4 CH3 CH2 CH1 Switcl H xX 00H Normal mode non synchronized 01 to FFH Synchronized output mode OH Normal resolution mode 1 to FH High resolution mode 0H Normal mode D A conversion processing 1 to FH Offset gain setting mode ans Output range setting value can be set within the ranges described below depending on the D A converter
8. module s model name e Q68DAV OH 2H to 4H FH 1 The module activates at the analog output range within 1 to 5V when OH is set e Q68DAI OH 1H FH 2 Switch 3 is set at decimal unit Setting is comparatively easier when the input type is change to decimal External Dimensions E Q68DAO AW Ea ERROR o a a 7 g 8 g 0 1 2 3 al 5 5 6 GIE ys E AET As lt FG terminal L shaped gt S we metal fitting ol FG terminal screw M3 screw unit mm in Warranty A Mitsubishi Electric shall not be liable for any loss caused by reasons for which Mitsubishi is not held accountable lost business opportunities or unrealized gain on the customer s side resulting from failure of the product or any other damage secondary disaster accident damage to equipment other than the product or disruption of other business operations arising out of special circumstances which may or may not have been predicted at Mitsubishi For safe use of the product e This product is manufactured as a general purpose product intended for general industrial use only It is not designed nor manufactured for use in an equipment or system affecting human lives e lf you are considering to use this product in equipment or systems for nuclear power gener
9. the module Not doing so may cause damage to the module Do not directly touch the conductive area or electronic components of the module Doing so may cause malfunction or failure in the module Always ground the FG terminal for the PLC There is a risk of electric shock or malfunction When turning on the power and operating the module after wiring is completed always attach the terminal cover that comes with the product There is a risk of electric shock if the terminal cover is not attached Tighten the terminal screws within the range of specified torque If the terminal screws are loose it may result in short circuits or malfunction If the terminal screws are tightened too much it may cause damage to the screw and or the module resulting in short circuits or malfunction Be careful not to let foreign matters such as sawdust or wire chips get inside the module These may cause fires failure or malfunction The top surface of the module is covered with protective film to prevent foreign objects such as cable offcuts from entering the module when wiring Do not remove this film until the wiring is complete Before operating the system be sure to remove the film to provide adequate heat ventilation About This Manual The following manuals are also related to this product Order them if necessary Related Manual Manual No Model code 5 SH 080054 D A Converter Module User s Manual 13JR02 Conformation to the E
10. tion to the Ministry of International Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan on recycled paper
11. ual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user DESIGN PRECAUTIONS e Do not bunch the control wires or communication cables with the main circuit or power wires or install them close to each other They should be installed 100 mm 3 94 inch or more from each other Not doing so could result in noise that may cause malfunction INSTALLATION PRECAUTIONS e Use the PLC in an environment that meets the general specifications given in the User s Manual of the CPU module being used Using this PLC in an environment outside the range of the general specifications may cause electric shock fire malfunction and damage to or deterioration of the product When installing the module securely insert the module fixing tabs into the mounting holes of the base unit while pressing the installation lever located a t the bottom of the module downward Improper installation may result in malfunction breakdown or the module coming loose and dropping Securely fix the module with screws if it is subject to vibration during use Tighten the screws within the range of specified torque If the screws are loose it may cause the module to fallout short circuits or malfunction If the screws are tightened too much it may cause damage to the screw and or the module resulting in fallout short circuits or malfunction Switch all phases of the external power supply off when mounting or removing
Download Pdf Manuals
Related Search
Related Contents
User's Manual Canon 9356B001 Digital Camera User Manual APG15 and 13 Service Manual doblò cargo - Fiat Auto.it Montage- und Bedienungsanleitung Thermaltake Purepower RX 500W Avira User Manual - Xpress Platforms Piano Operativo di Sicurezza SwissVoice CP-20 EZweb - KDDI Copyright © All rights reserved.