        Swimmimg Pool Disinfection - Aquarius Technologies Pty Ltd
         Contents
1.      When  the calibration is complete the screen will display    TEMPERATURE  CAL OK    press ENT on the key pad and the conductivity calibration  screen displays        Steps in Conductivity Calibration    This screen is used to calibrate the conductivity sensor  To  begin  enter the actual conductivity of the solution being used for  calibration  If using tower system water  the value is read from  the independent conductivity meter  Or enter your calibration  solution value into the screen     When performing a calibration  change the conductivity value via  the t  Up  and    Down  arrows on the key pad  If required after  your calibration solution figure is showing on the screen  place the  probe in the solution and press ENT and the screen will display the  message    PROBE STABILISING PLEASE WAIT     Press ENT key  on the key pad when complete and the screen will display    COND    VALUE  CAL OK     Press the ENT key a second time and the menu  will return to the    CHOOSE CAL MODE      screen     Note  It is important to clean the conductivity probe before calibrating  conductivity     Part Number  AS1413   1413 uS cm          2    Scenic 2    Erase Calibration Mode    There may be times when the user decides to set the controller  calibration back to factory defaults  This is achieved by erasing the  controller   s calibration data     The user will be asked to confirm this action and once  accepted the menu will return to the    CHOOSE CAL MODE    screen  The contro
2.    Aquarius BMS  Controller GND Computar    It is recommended that a 250 Ohm sense resistor  is used at the BMS end of the connection for each  4 20 mA input     providing the BMS a 1  5 volt DC  input across the range of measurement     Note  In cases where the BMS requires a 2 10 volt  analog input  500 Ohm sense resistor   the 4 20  mA output may only be accurate up to 95  of the  maximum scale     Event Outputs   Both the 4 channel     C    Series  and 8 channel   KPI 3  BMS options provide for ON OFF  clean  contact switching for the current status of Alarm     28    Flow and all available relay outputs    Relay numbering is consistent within each family  of controllers  but dynamic across the full range   so relay numbers may change depending on your  software configuration  The relay numbering for  each software configuration is easily obtained by  running the Test Outputs routine     To enter the Test Outputs routine  press and hold  the READ key for 5 seconds  Now press the  ENTER key to move the cursor to the MAN AUTO  selection  Press the DOWN arrow key to select  AUTO Test outputs operation  The controller will  now cycle the output relays from REL1 through  all available relays for 5 seconds each  As each  output turns ON  the module and relay number are  displayed in the Test Outputs window as follows   Line 3  RL1     pH ON  5    Flow and Alarm relays are common across all  controllers and are clearly labelled on the BMS  Connector Board     Relays COM    Relay
3.  4736    Upon receipt your controller will be regis   tered in our equipment database  This will  provide a ready confirmation of the actual  equipment installed  and the configuration  characteristics at your specific installation   This information will assist greatly with our  treatment of technical and service inquiries  in the future        TECHNOLOGIES PTY LTD         WATER QUALITY CONTROL       32    
4.  OP         Aquarius l  Conindler         aces    The COMMON of each Event Output relay can  be supplied by a USER signal   5   12  etc  from  BMS into RLY S  COM  or use an internal  12 volt  DC signal from the controller  for isolated inputs    This selection is made by placing the jumper on  JP2 to either  12V or RLYS COMM     The jumpers on JP1 are connecting each Event  Output relay COMMON to the supply selected with  JP2  to save on external wiring     in most cases a  common supply is sufficient   By removing these  jumpers the user can choose to individually wire  each relay  providing true clean contact switching  for all outputs     NScumecnicuiciicim 2    Conversions to Engineering Units    Each 1   5 volt DC analog input will need to  be converted back into its appropriate unit of  measurement     Conversions for each input are as follows     ParameterConversion Units  Temperature  0 99 9      value    1  4  100    Conductivity  0  9 99     value    1  4  10 mS cm  ORP  0 999      value     1  4  1000 mV  pH  0 14 00       value      1    4   14 00 pH  Corrosion Rates   as umPY1  0     1000      value      1    4   1000 umPY  as PIT1  0      1000      value      1    4   1000 PIT  as umPY2  0      1000      value      1    4   1000 umPY  as PIT2  0      1000      value      1    4   1000 PIT    Note   value    DC volts   input   4 00 Volts  Example  pH     4      1   4  14 00      3  4  14 00    0 75  14 00   10 50 pH    Useful Contact Information    Aquarius Tech
5.  contact on empty   default  or open contact on empty  To change  remove circlip from  bottom of Tank Alarm and reverse the float     Designed for simple installation  Simply cut or drill 25mm hole in  the drum cap  mount the compression gland into the cap  insert  the Tank Alarm through the bottom of the gland  adjust height to  desired depth and tighten compression gland     For wiring into Tank Alarm Box  refer to diagram on the left     Scumecnieticiicnn 2    Data Logging and Communications Set up    Data logging facilities are a standard in all     C    series controllers  and with the Data Log  interval set to 30 mins   over 4 weeks of data  logged on a 24 7 basis  can be stored before it  is over written  See Set Data Logger Screen on  page 15     Down loading the Data Log    The data in the data log can be retrieved in a  numbers of ways namely      1  The data log can be down loaded locally to  a laptop using the Free HyperTerminal pro   gram available in Microsoft Windows pro   gram  via a Serial cable attached to a laptop  and to the DB9 connector fitted internally in  the controller     2  Ifa GSM modem and a SIM data card have  been fitted  the data log can be retrieved re   motely by again using HyperTerminal     Both of these methods retrieve the data log in text  format which will need further importation into an  Excel spreadsheet for trending and graphing for  reporting means     3  Using AquaGuard 2  30 day trial version  or  AquaGuard 2   Activation Key  a
6.  measured parameters are displayed     Calibration     Access from the CAL button    The following instructions provide a detailed explanation of the  Probes  Conductivity  and Temperature Calibration  Calibration of  the pH probe and verification of the ORP probe are very similar  processes  When calibrating the probes the user has the option of  setting both probes in combination or setting each probe individually   Only use individual calibration when a single probe has been  replaced or adjusted     Press the CAL button on the front panel  The calibration mode  selection screen will appear on the alphanumeric display  By  pressing the t  Up  and    Down  arrows the user can cycle all of the  calibration modes indicated in the menu tree diagram     Combination Calibration Mode    As both the pH and ORP sensors are contained within the one  electrode it is possible to perform both pH calibration and ORP  verification in one step  For this you will need Aquarius combination  buffers     Part Number  AS7086   pH 7 01  amp  86 mV  Part Number  AS4250   pH 4 01  amp  250 mV    ise Water Usage Meter  WUM  Totals Mode    IM total value can be reset from here  Pressing ENT will bring  to a second screen for confirmation     pH Calibration Mode   To calibrate pH separately press ENT for pH calibration   Then place the probe in pH solution and press ENT  when ready  The screen will display the message     PROBE STABILISING PLEASE WAIT     When complete the screen  will display the v
7.  preparation      improper maintenance  adjustment     modification or contamination caused or  induced by the Buyer      the Product being used or attempted to be  used in a manner which is beyond normal  commercial capacity and application of the  Product      any abuse or misuse of the Product including   operation of the Product in circumstances   where there may be subject to irregular  electrical supply    then  Aquarius will at its option either     repair any part of the Product which is proven   to be defective in material or workmanship   upon the Aquarius    examination  The repairs  will be carried out by Aquarius personnel or  persons appointed by Aquarius at Aquarius  premises or at the site or premises of the  supplier to Aquarius  This warranty does not  include removal  installation costs  or liability  exceeding the selling price of the Product    Aquarius warrants that all repairs on returned   Product will be free from defects in materials   and workmanship for a period of sixty  60    days  or    vi  replace the Product    3  The Buyer will be liable to Aquarius for all  reasonable costs incurred by Aquarius in  relation to the investigation  analysis and  testing of a Product which are not defective in  the reasonable opinion of Aquarius            4  Inno circumstances will Aquarius              incur liability in respect of  or arising out of  or   in connection with harm or injury suffered or   incurred by the Buyer     ii  incur liability in respect 
8.  short cut start  from step 4     We now have the downloaded data from  the controller in text form  The txt file can  now be imported into an Excel spreadsheet  to obtain trend graphs etc      9  Open up the Excel spreadsheet  it will ask  you what file you would like to import  Select  the file as named in step 4     10  The data will import into the spreadsheet and  you can commence to set up trend reports   graphs  etc     25    P   System Configuration    GSM MODEM SET UP    SIM Card setup   Provider   1  Aquarius recommends using Telstra as a  Service Provider for Data Communications  in Australia   between AquaGuard and the  Water Treatment Controller     2  When requesting a new account from your  Service Provider  the following information  should be given to them in order to receive  a SIM card that is data enabled and has the  correct phone number     a  Advise the Service Provider that you require  a Data enabled SIM Card   b The account should have no voice  message service   c  The account should be stripped of all  auxiliary services   d Ask for the Data Telephone Number  as well as the Voice Number of the  account    request from Service    3  Once you receive your new SIM card perform  the following functions    a  Remove all password protection from the SIM   ie  no Pin Numbers to switch on  This  can be done by inserting the SIM card into a  telephone and removing the PIN activation on  start up   b  Insert SIM card into the modem by removing  the black cov
9.  to  10 00    Use arrow keys to cycle these  selections     MODE    FLOW  Options  OFF FLOW   CON     Use arrow keys to cycle these  selections    ALM          Options       alarm if above specified  value       alarm if below specified    value         alarm if outside specified  range    OFF  Alarm disabled     Use arrow keys to cycle these  selections     16    Set Alarm Screen   Name and Phone    Allows the user to enter up to three names and contact phone numbers  to receive notification of system alarms via mobile phone sms alerts   Only available when a Communications Kit is fitted to  the controller    Options   three phone numbers    PH1 PH2 PH3 Use the arrow keys to cycle through these  selections    Press ENT to place the cursor on the NAME field and use arrow  keys to select characters  Press ENT to select and move the  cursor to the next character  Pressing ENT a second time will  move the cursor to the NUM field  The same process applies  for entering the telephone number  the arrow keys cycle  numbers 0 through 9 and ENT to move to the next number     Set Conductivity Screen  Refer to Table 1  Adjacent   Allows the user to set the conductivity options for the controller     mS cm is a read only value generated by the controller  It conveys  the actual value measured by the conductivity sensor  in millisiemens  per centimetre     Table 1          Models CT C  x  S i A amp P          Conductivity Series Series Series Series Series  Options Above    Available Belo
10.  to the BOC Regulator  Operating Instructions brochure supplied with  each regulator     Installation Guidelines 1    Maintenance and Care of Sensors    Foulants can lead to inaccurate sensor readings   Sensors should be cleaned and calibrated  regularly using the following procedures     Cleaning of Flow Conductivity Temp Sensor  Isolate the flow to the manifold     Remove the locking nut from the Flow   Conductivity Temp sensor     Abrade the sensor surface with 300   400 grade  wet   and    dry paper until the surface is clean   the two carbon electrode surfaces are clearly  visible  and the surface wets out freely     Ensure flow paddle is free from debris  Rinse  the sensor in fresh water and replace it in the  manifold     Cleaning of pH ORP sensor  Isolate flow to the manifold     Remove the sensors from the manifold by  loosening the lock nut and withdrawing the  sensor from the manifold     Rinse the sensors in fresh tap water and  remove any visible fouling  This should be done  carefully by lightly scrubbing with a tooth brush  or similar     Place the sensors in the Electrode Cleaner  solution  AS9500  for about 5 minutes to  completely dissolve any trace of inorganic  foulants     Remove and rinse thoroughly in fresh water  before replacing it in the manifold     Proceed to calibration or verification of sensors  as outlined in the commissioning section     Accessories and Spare Parts  Reagents    AS1413  1413 uS cm conductivity solution  AS7004   pH 4 buffer sol
11. 10 15 Amp Mains  Cortroler    Supply input    ABbocuecietcuen    CAL Menu  Functions    y N ENTER        Aquarius Control Systems     Calibration Mode Your new Aquarius controller system features a front       Combo Cal panel that consists of        pH Calibration     ORP Verification Screen   s Cond Temp Cal A 4x20 line alphanumeric display   s Conductivity Cal   s Erase Calibration Buttons   s Panel Selection The six button key pad is the primary user interface  The  s Front Screen buttons provide the means to navigate the screens and  set the operational parameters for your desired treatment  program     READ  Used to display READ only screens    SET  Used to display SET screens    CAL  Used to access sensor calibration screens      Up   amp  Used to scroll between screens      Down    arrows or alter values for input     ENT  Enter   Used to complete or confirm an action   This will move the process to the next  programmable function     10    ME ET 2    Default Screen    The factory setting is to show the    default    screen on power up  The  Aquarius    default    screen displays Company Name  name identifier  of the equipment  firmware version  and the current system date and  time  If there is an active system alarm  details will be displayed on  the fourth line instead of LSI and alarm reading  Users may also  configure the controller to show the current sensor readings instead  of the default screen  If the sensor readings screen is selected  all  current values of
12. Models for  Swimming Pools using  Hypo and Liquid Acid    SL100WP  SL111  SL113  SL136    Models for Swimming  Pools using Hypo and  CO2 Gas    SC100WP  SC101   C103  SC106    Models for Swimming    Models for    Pools using Electrolytic Swimming Pools using    Chlorinators and Acid    SE100WP  SE110  SE130    Electrolytic Chlorinator  and CO2 Gas    SE100C    Swimmimg Pool  Disinfection  Controllers    USER MANUAL    May 2010 Version 15 0    TECHNOLOGIES PTY LTD    A AQUARIUS    y    Se Co  GB _AB water QUALITY CONTROL          Congratulations 3   Where to find the serial number 4   Section contents 5   Installation guidelines   Section 1 6   System configuration   Section 2 10   Manufacturer   s Warranty   Section 3 610   Unit 1  23    Richland Avenue    Coopers Plains QLD 4108 E ONSE eN    f   07  3274 4736    PO Box 71   e  Coopers Plains QLD 4108 be AMARES NE R  AUSTRALIA e  info aquariustech com au    This document is subjected to Aquarius Technologies Pty Ltd trading terms and conditions  which can be obtained from the following link httpo   www aquariustech com au terms html          Aquarius Water Treatment Controllers    Congratulations    We know you will be happy with your decision  to purchase a new Aquarius Technologies  Controller  These units are now supplied with  standard features that are considered optional  extras in most other systems  if available at all     The updated software now incorporates our  newly released Aquarius Proprietary Logic   APL   whi
13. XT fields are only visible if a Superchlorination  program is set     WK  The interval between cycles in weeks  NXT  Date next Superchlorination will occur     For descriptions and information on setting these items  refer to the  section Set Superchlorination Screen     23    P   System Configuration       1   Gue   a  Weipt cep    Wiring into Cortrotier       LSI FAH Read Screen    This screen displays the calculated values  for Langelier Saturation Index and Free Available Halogen     LSI  Current calculated value for LSI  CAL  H  Value entered for calcium hardness  FAH  Current calculated value of FAH    For descriptions and information on entering user data  refer to the  relevant Set Screen sections     Protocol Read Screen  This screen displays the selected protocol mode of the controller     BD  115200 9600   MODE  AQUAGUARD MODBUS   Slave Addr  Current address assigned for MODBUS   TX  Current status of transmit   RX  Current status of receive   ERR  Current indication of communication errors    For descriptions and information on setting the protocol  refer to the  section Set Protocol Screen     For further instructions on the operation of this interface refer to  AquaGuard Brochure and Manual    Tank Alarm    Tank alarms come in two sizes TANK_ALARM_SM  500mm   complete with 3m suction tube  drum weight and 3m connection  cable or TANK_ALARM_LG  1000mm  complete with 5m suction  tube  drum weight and 5m connection cable     Tank Alarms can be configured for closed
14. alue and prompt the user to press ENT to continue   At this point  the menu will return to the    CHOOSE CAL MODE       screen     Part Number  AS7004   pH 4 01  Part Number  AS7007   pH 7 01       11    NO    System Configuration    ORP Verification Mode   To verify ORP separately press ENT for ORP verification  Then  place the probe in the requested solution and press ENT  The  screen will display the message    PROBE STABILISING PLEASE  WAIT     Then rinse the probe in fresh water and place it in the second  solution requested  press ENT when ready  The screen will display  the message    PROBE STABILISING PLEASE WAIT     When this  is completed the user will be prompted to press ENT and will be  returned to the    CHOOSE CAL MODE      screen     Part Number  AS7250   250 mV  Part Number  AS7475   475 mV    Cond Temp Mode    To calibrate Cond Temp press ENT for Cond Temp calibration  Press  the ENT key on the key pad to access the temperature calibration  sub menu     Steps in Temperature Calibration    Conductivity is calibrated by first setting temperature and this  is important or invalid performance may result  To set the water  temperature sensor  enter the actual temperature  as read from  a thermometer  or accept the temperature value displayed on the  screen  The temperature value is changed via the t  Up  and     Down  arrows on the key pad  To accept the reading displayed   press the ENT key on the key pad     The message screen changes to indicate    PLEASE WAIT
15. ch has capabilities to control  monitoring and responses to much tighter  tolerances that were ever possible in earlier  models     You also have the comfort of knowing that  these models are capable of being upgraded  by connecting to a notebook computer  locally  or via the optional cellular communications  package  They are also scalable in terms of  adding modules to expand capacity over time     Models covered by this Manual    Let us help you to learn about your new  Controller  This manual will take you through  all of the functions available from the keyboard  and display  and provide a clear and logical  sequence for processing the configuration  settings     Please also take the time to send us details  of the Installation on the Registration Form  provided  This will enable us to provide the very  best level of technical support should you need  to contact us for any reason     e Models for Swimming Pools using Sodium Hypochlorite and Hydrochloric Acid   SL Series   e Models for Swimming Pools using Sodium Hypochlorite and CO2 Gas   SC Series   e Models for Swimming Pools using Electrolytic Chlorinators and Hydrochloric Acid   SE Series  e Models for Swimming Pools using Electrolytic Chlorinators and CO2 Gas   SE C Series    Where to find the serial number                Model SC110    Serial Identification Label    All Aquarius Technologies Controllers are  manufactured with a Serial Identification Label   SIL      This will be affixed to the wall of the controlle
16. d Screen 24  Aquarius Control Systems 10 Frotocol ead Sargen 24  Tank Alarm  with wiring instructions  24  Arin 7 Data Logging  amp  Communications Setup 25    Default Screen i    Hyper Terminal Set Up 25    Calibration     Access from the CAL button 11    GSM modem set up 26  So oe e Adding a SIM card to GSM modem 26  Combination Calibration Mode 11     Adding phones nos for Alarms 26  E ender Mode A   Using AquaGuard 2 software 27    ae Verification PA 12 Adding AquaGuard 2 Activation Key a  a Cond Temp Mode 12 bd BMS 4  20 mA Interface  e Steps in Temperature Calibration 12  e Steps in Conductivity Calibration 12 3 Warranty  amp  Registration  e Erase Calibration Mode 13  i N oy aac E Manufacturer   s product warranty  e Source Data Screen 13  Commissioning  amp  Warranty Registration 31    gif Installation Guidelines    Important    1  It should not be installed within the pool zone   i e  within 3 meters of the water according to  current definition     2  If the supply cord is damaged  it shall be  replaced by the manufacturer or its service  agents or similarly qualified person in order to  avoid a hazard     Before you start    Select a suitable location for installation    preferably in close proximity to the main system   protected from the public and environmental  factors such as direct sunlight  A wall area of  approx  0 75 m  wide by 1 0 m  high is ideal for  mounting your controller  A minimum floor area  of approx  1 5 m x 0 6 m below the controller is  requir
17. details of your controller here     Controller   Serial NUMDGMS  sspears    Date Installed  assuri  Pumps    1   serial nNUMber nnsa  2   Serial MUMDED           ccccceeeeceeeeeeeeeeeeeeeeee  3   Serial NUMDE isinisisi nsina  4   serial MUMDEE             c eeeeeeeeeeeeeeeeteeeeeee  5   serial MUMDEL nsaan    6   Serial number            cceeeeceeeceeeeeeeeeeeeees    29    _ Manufacturer s Product Warranty    AQUARIUS TECHNOLOGIES PTY LTD    Manufacturer   s Product Warranty Definitions     Aquarius    means Aquarius Technologies Pty  Ltd ABN 94 010 393 254       Product    means       i    goods purchased from Aquarius that have  been manufactured in whole by Aquarius   and     ii  the Aquarius manufactured components in  third party goods        Buyer    means any person or entity who buys  product for consideration from Aquarius        The Law    means and includes the Trade  Practices Act  Commonwealth  1974 and relevant  State and Territory fair trading or other consumer  protection legislation and includes any statute  amending  consolidating or replacing the same  from time to time     Warranty   1  Aquarius warrants that      i  all Product is produced under a Quality  Assurance System to  1809001 2001  standards     ii  the Product conforms to the written description  in the purchase order quotation and related  purchase documentation accepted by  Aquarius in writing except for such defects that  are normally regarded as being commercially  acceptable     iii  the Pr
18. ed for the chemical tanks  This will vary  according to the number and type of chemicals  being used for dosing     It is important to consider environmental  elements when installing  It is a requirement  to provide protection for accidental spills of  chemicals and that includes any leaks that  can develop from pump pressure lines  Some  chemicals will damage materials used in  construction of buildings  particularly roofing   Never assume that the equipment will not leak   under certain conditions that will occur  It is  the responsibility of the installer to ensure that  such events do not create damage that should  have been avoided by correct site selection  and the provision of adequate bunding at the  time of installation     Minimum system requirements    There are several minimum requirements that  should be established BEFORE the controller  is installed     e Minimum 20 mm  3 4  take off and line to  supply sample water to the system     e Minimum 12 litres minute supply flow to  ensure proper operation of sample readings   dosage and bleed off rates    e Adequate bunding is provided for the system    and chemical drums to prevent spills causing  damage     e Availability of approved connection to  power  A    clean    220   250 vac 50 Hz    10 amps supply  some options may need  more than one outlet  or increased current    capability      The terminal strips supplied with the controller  activate a 240V AC supply rated   7A  combined  These terminals are active 
19. er situated below the LED  lifting  the SIM holder  and placing the SIM in the  slot  Remember to push the SIM card holder  into the LOCK position    c  Record the Data telephone number in a safe  place  Aquarius recommends placing a sticker  with the number on the modem itself     4  All messaging and other features can now be  setup via AquaGuard     5  Should there be any further problems in  accessing data or receiving SMS messages  from the SIM card  Please contact the  Telstra Help Desk on 1800 010 253 Option  2 or your Service Provider who are  equipped to deal with Data Accounts etc     Programming a GSM modem        You communicate with your modem via a serial  communications program such as HyperTerminal   Telix  etc  Plug the cable provided from the  modem into the serial port of your computer     26    Set up the communications program for direct  connection to your serial port  COM1  COM2    at 9600 Baud  8 Data  amp  1 Stop Bit  with no Parity  or Flow Control  The AT amp V command   ENTER   should now return the current modem settings  to the screen  Once you have established  communications with the modem you can begin  the Set Up using the following commands     Modem Alarm Setup for    C    series controllers   Check Registered phone numbers  AT CPBR 1 10   Delete all registered phone numbers  AT CPBW  lt index gt    Enable the use of text mode parameters  AT CSDH 1   Set text mode parameters   AT CSMP 17 167   Switch the module to text mode   AT CMGF 1   Sa
20. ge in case  of sensor failure    Models   pH         Options  Available    Default Mode    Unsafe minimum  pH warning            Unsafe maximum  pH warning    Default Values          Scumecnieticiicnn 2    Set Water Usage Meter  WUM  Screen    Allows user to set amount of water per impluse   Use the ENT key to switch between the items  Then use the  arrow keys to cycle these selections     Eg  Value for Makeup Bleed Bkwash can be set from Disabled to  1 Plse   0 251 would be used if 1000 Itr per Pulse     water meter provides 4 pulses  per litre  Water Meter Cable Connection  Water Meter for Makeup line is to be connected to mainboard    1 Plse   10 01 would indicate 1 through the terminals for WM  amp  Gnd   pulse per 10 litres        Set Superchlorination Screen    Refer to the Table 4  below  Allows the user to utilise a function of  the controller that applies a boost disinfection  superchlorination   by means of raising the ORP control set point and dosing oxidising  biocide according to the program set  This program is for a time  interval in hours on any one day of the week  on any frequency of                 DAY   OFF  weeks  The program allows the user to enter the day  start time    Options   day of duration  frequency interval  and the ORP control set point    Superchlorination  Day OFF  Table 4    Use arrow keys to cycle these Models     selections  Disinfection Ci c  x  S T A amp P  Super Series Series Series Series Series   START   0  Chlorination   Options   S
21. hen the cursor is on one of the alarm modes press ENT to change  the numerical values associated with that alarm  Select from the  values of 25  50  100  150  200  300  and 400  These values are the  range from the set point that will trigger an alarm  Press the ENT  again to move to the next set ORP item    Alarm defaults  Min  400   Max  750    The controller has factory defaults which will issue alarms when  these values are exceeded    LOCK   OFF    Options   Preferred lockout period    Value In the range of 10 to 990 minutes    OFF   disabled   Use arrow keys to cycle these selections     If the lockout time is greater than 10 the lockout function is active   The controller will then    lock out    output after the selected time has  elapsed without the controller having reached its nominated set  point for ORP  This is a safety feature to prevent overdosage in  case of sensor failure     17    P   System Configuration       SET   7 50    Options  Values in the range  3 00 to 11 00   Use arrow keys to cycle these  selections     DUTY   50     Pump Dose  Duty    Options  Values in the range 1 to  100    Use arrow keys to cycle these  selections    DOSE STATE   A    Options  AIB   Use arrow keys to cycle these  selections     18    Set pH Screen    Refer to Table 3  Adjacent    Allows the user to set the pH options  This screen should never  require changing whilst in a monitoring mode  pH is a read  only value generated by the controller and is not a value that can be  se
22. ions for interfaces to  external features    MODE   Aquaguard    Options  Aquaguard MODBUS    Use arrow keys to cycle these selections        READ Menu  Functions       The Read Status Mode   Aquarius controllers offer a number of read only    Alarms screens that show the status of the current treatment     Sensor Status program  These are read only screens and cannot be     Conductivity used to modify a program      ORP Moving Between Read only Screens and Set    pH Program Screens     ination i      LSI FAH It is possible to jump from a read only screen to  the corresponding set program screen by pressing    Protocol the SET key  Similarly  the user can move from a    set program screen to the corresponding read   only  screen by pressing the READ key        20    Scumecnieticiicne 2    Alarm Read Screen    The alarm read screen shows the configuration of the system  alarms  The second line of the display shows how often alarms will  be retransmitted  The third line displays current active alarm     Note  where multiple alarms are active the screen will briefly rotate  each alarm into view     Thus the following could appear on the third line display     Temp  Temp    CAL ORIG OUT OF CAL  Cond  Cond    CAL ORIG OUT OF CAL  ORP  ORP    CAL ORIG OUT OF CAL  pH  pH    CAL ORIG OUT OF CAL  Conductivity 300s   ORP 300s   pH 300s    Sensor Alarms have a five minute delay  The 300s  Seconds  will  count down to zero before the alarm is activated     Sensors Status Screen   This sc
23. ire strainers should be checked for correct  operation and cleaned of any debris every  month     Injection non return valves and pumps should  be cleaned and checked at least annually     Sodium Hypochlorite being highly alkaline may  lead to scale formation on its dose injector and  this require acid cleaning on a frequent basis     On the peristaltic dose pumps  the squeeze  tubes and roller block should be checked at  least annually and should be replaced every  1 2 years     More regular maintenance may be required  for the larger 3 0 I hr pumps  due to increased  pumping rates     Chemical suction and discharge tubes  should be inspected monthly and replaced as  necessary   3 Months 6 Months    1 Year 2 Years       Verify Flow ON OFF       Verify pH  ORP Probe       Test Outputs       eal ee      Test Pumps Solenoid Operation       Clean and Calibrate pH ORP Probe       Check Clean Injectors       Inspect Suction Discharge Tubing       Check Clean Solenoids       Peri  Pump   AP Service Kit             Peri  Pump   AP Overhaul Kit                      8    AELEKEE CEES 1    i      Drilling Dimensions  fi                or  Wall Mounting  of Controller                                                                                                                                           FILTER  POOL    Z z   K H m  Pe   CIRC E  PUMP  Typical Installation Schematic  SE100 Chlorinator  Wiring Diagram  eee a      1 10 15 A supply To  Chiormator or       From ORP output in 
24. ller will then have settings that are  factory defaults as outlined in the product specification sheet   It is very likely that in this event the user will need to perform the  calibration process again     Panel Selection Mode    While in calibration mode the user has the choice of viewing either  the standard Aquarius default screen or having all sensor data  displayed as the default screen  To make this selection press ENT  and there will be a prompt to select the default option     Factory Alert Screen    The Factory Alert Screen provides a warning function and will display  when configuration is required from factory settings  This screen  prompts the user to start a major system setup     Source Data Screen  The Source Data screen is accessed by holding down the SET key     XX Series  Series of Controller    SN  Controller Serial Number  V2 01 30  Firmware Version  CHK  Firmware Checksum    BV1 0 18  Bootloader version  19 01 05  Date of Manufacture    13    Pd System Configuration    Set Screens Menu   All Aquarius controllers come loaded with preset default values for  all of the treatment program parameters  On start up the controller  will operate according to those defaults  However  every application  should have a planned treatment program developed  Decisions  need to be made on what values are most appropriate for ORP  pH   Conductivity requirements  Once the program has been determined   it may be set in the Aquarius controller  as described in the following  
25. llow for the  data to be download into a database and with  direct importation into an Excel spreadsheet    CWT_Graphs xlt template to automate the  graphing  summary  and trending charts  and  speed up reporting  Use of a serial cable  and a laptop allows for local download as in  No  1 above     4  Where a GSM modem with a SIM data card  has been fitted   full remote control is avail   able using AquaGuard 2 software as in 3  above  plus alarms to 3 phones  and remote  start up of disinfection  or changes to set  points   all from the PC or laptop in your of   fice or car     HyperTerminal Setup    1  Start Programs  Accessories  Communi   cation  HyperTerminal to start the program   the program that is run is hypertrm exe     2  Start a session called Download  or another  meaningful name      3  Select using    Direct to Com 1     the most  likely communications port   It will then ask  for settings of COM1  Select 9600 baud  8  bits  no parity  1 stop bit and no flow con   trol     4  Select Transfer Capture Text and name  your file as normal download file names i e   Site month year txt  e g  XYZ0406 txt for a  April 2006 download at site XYZ      5  Press         then downloads will start as nor   mal     6  At the end of the download  select Transfer  Capture Text Stop     7  The file with a  ht extension will be saved by  selecting File Save     8  Make a short cut on the desktop to this file   All the settings will then be configured so  when you go into it from the
26. nologies Pty Ltd  ABN 94 010 393 254    Technical Support     Phone    617 3274 4750  Fax    617 3274 4736  email  techsupport aquariustech com au    Postal Address   PO Box 71  Coopers Plains Q 4108  Australia    Delivery Address   1 21 Richland Avenue  Coopers Plains Q 4108  Australia    Trading hours   08 00 to 17 00 Monday   Friday  Australian EST    Testing    Once all connections have been made and all  conversions entered into the BMS  the BMS  interface must be verified     For all analog inputs the reading on your BMS  display should be within 1  of the reading  displayed in the data display window on the  controller  If the BMS allows  these readings can  be calibrated to more accurately represent the  controllers    reading     If one or more readings is out of tolerance or  cannot be calibrated check your conversions and  record voltages at the input  If the voltage is OK  the problem is most likely in the conversion  If  the voltage is not OK  check the sense resistor  value and all cabling  LED   s L1 thru 8  on the 4 20  Interface Board  illuminate to highlight open circuit  or high resistance current loops     For testing of Event Outputs  run the Test Outputs  routine whilst watching the BMS display  You  should see each relay output cycle ON for 5  seconds them OFF  Turn Flow ON and OFF and  watch for the flow indication at the BMS  Set an  Alarm in the controller  remove sensor  alter SET  point etc   and look for an Alarm indication at the  BMS     Record 
27. ockout period in minutes or OFF    For descriptions and information on setting these items  refer to the  section Set pH Screen     Note  If LOCK is flashing the controller is exercising lockout  This  can only be released after correcting the cause and visiting the Set  pH Screen     The reset is achieved by toggling the lock OFF then re entering  the lock value     22    NScumecmic vice 2    Water Usage Meter  WUM  Read Screen    This screen displays the total water usage readings for Makeup   Bleed  amp  their Difference  These values can be reset in the Calibration  menu     The corresponding screens display the Makeup  Bleed and  BackWash water meter readings  It also shows the usage as a  Month to Date  MTD   amp  Year to Date  YTD  figure     MTD figure will reset automatically on the ist day of the new  month     YTD figure will reset automatically on 1st Jan   The measurements in litres of each water meter will be data logged  for the selected datalog period     Note  Changing of log intervals within the time period will result in  inaccurate readings in AquaGuard 2  Log intervals is recommended  at 30min which allows for 1 month worth of data     Superchlorination Read Screen    This screen displays information about the Superchlorination  routines for the system        ON OFF  Superchlorination ON or OFF   DAY  The day selected for Superchlorination  START  Start time   DUR  Dosing duration in hours   SET  ORP control set point for Superchlorination    The WK and N
28. oduct will be reasonably fit for the  purpose of use described by Aquarius   however Aquarius accepts no responsibility  for third party misrepresentation     iv  the Product will be of merchantable quality  and free from defects in material and  workmanship    2  If within twelve  12  months  from either the  date of purchase by the Buyer or the date  of installation  whichever is the earliest   the Buyer gives to Aquarius written notice  that the Product does not correspond with  the description or is defective  and such  defect could not have been detected at the  time of delivery  and Aquarius agrees then   PROVIDED      i  that Aquarius  via its customer service  department  is contacted promptly     ii  that the Buyer supplies to Aquarius sufficient  proof of purchase  the model number and  serial number of the Product     iii  that if necessary  the Product is returned by  prepaid freight to Aquarius Technologies P L  factory headquarters      30     a  within fourteen  14  days of detection of the  alleged fault  and    b  in the same order and condition as that in  which it was delivered    c  packaged to prevent any damage in transit     d  that the product contains the return  authorisation number  customer identification  number  and return delivery details   AND    iv  if any alleged defect or failure to correspond  with description has not arisen from      alleged defect or failure to correspond with    description   e improper or incorrect installation or site 
29. of any special  consequential direct or indirect loss or  damage     iii  accept liability for the cost of any repair   or attempted repair by the Buyer by any   unauthorised third party     Commissioning  amp  Warranty Registration    This form should be completed by the Equipment OWNER promptly after installation  amp  commissioning   When signed is should be faxed to Aquarius Technologies Pty Ltd on  617 3274 4736  This will ensure  the equipment details are logged to our confidential Warranty Database to activate your warranty  registration and assist our ability to process any future service inquiries     Please print all details except for signatures    Models ea a e EAR A R A AA Senal No AT S    Date of Installation  n a a    The above equipment was satisfactorily commissioned for     Owner GompamysNarnie  R E E E A AN  Addressit  PEA EE EEEE AE AEAEE E EEE ITT  Address 2 A A E E A E sneer aera    States reedeneeenovseesrenesreretests GOUNUV a a ee e e    Signed for and on behalf of the Equipment OWNER    Names T E AE E A E A E    Commissioning CompanyName m ma e A A A A E E et cease  Address  a E E EEE E    State TTT eee COUN E A herrea E    techniciamiName ea a tecees cer ece etc eae    Datei nR T Signat  re taarna E o E EAE    Thank you for your very valuable support  purchase and installation    Aquarius Technologies Pty Ltd    _ Warranty Registration    Faxing Instructions for Registration    Fax this form immediately to    Aquarius Technologies Pty Ltd   617 3274
30. r   on the outside face on the right side     The label is the best reference for making  inquiries for service or Technical Assistance     Any controller that does not show evidence of  the SIL may have the warranty voided     Key data being     Model  e g  SC110  This is actual Controller model and indicates  the configuration     Build  e g  OCT 05  Would indicate this controller was  manufactured in October 2005    Serial No  e g  0510SC11011  Is the specific serial number for this Controller    Section Contents    1 Installation Guidelines I2 System Configuration    Minimum System Requirements Set Screens Menu   e Key Pad Function a  Maintence  amp  Care of Sensors    Set Time  amp  Date Screen 15    Cleaning Flow Conductivity Temp sensor 7    a a e    Cleaning pH ORP 7      SENNIE eee e Set Alarms Screen   Name  amp  Phone 16  Accessories  amp  Spare Parts e Set Conductivity Screen 16    Reagents 7   Set ORP Screen 17    Sensors 7 7 Set pH Screen 18    Peristaltic Pumps 7    Set Water Usage Meter Screen 19    Test Meters T    Set Superchlorination Screen 19     Set Calcium Hardness Screen 20  Routine Testing 7    Set Protocol Screen 20  Warnings 8 Read Mode 20  Regular Inspections  amp  Maintenance 8   Alarm Read Screen 21  Typical Installation Schematic 5   ee sal a  ae     Conductivity Read Screen  SE100 Wiring Diagram 9 ORP Read Screen 22    pH Read Screen 22  2 System Configuration e Water Usage Meter Read Screen 23  e Superchlorination Read Screen 23  e LSI FAH Rea
31. reen displays the status of sensors    FLOW  ON OFF   CHEMS  LO OK   TEMP  Current Temperature of the System  in   C   DATALOG  The Interval set for Logging    Conductivity Read Screen  This screen displays the conductivity status        RL  relay   OFF ON   mS cm  millisiemens  centimetre   SET  the current control set value for Conductivity  FLOW  ON OFF   ALM  Will flash a value if alarmed   LOCK  Not available on Conductivity    For descriptions and information on setting these items  refer to the  Set Conductivity Screen     21      4 System Configuration    ORP Read Screen  This screen displays the ORP status     RL  relay   OFF ON   ORP  The current value of the ORP in millivolts  SET  the current control setting for ORP in millivolts  DUTY  The current dose pump duty set   MODE  ORP FLOW CON OFF   ALM  Will flash a value if alarmed   LOCK  Lockout period in minutes or OFF    For descriptions and information on setting these items  refer to the  section Set ORP screen     Note  If LOCK is flashing the controller is exercising lockout  This  can only be released after correcting the cause and visiting the Set  ORP Screen     The reset is achieved by toggling the lock OFF then re entering  the lock value     pH Read Screen  This screen displays the pH status        RL  relay   OFF ON   pH  Current value of pH   SET  The current control set value for pH  DUTY  The current duty set   Acid Base indicator  A B   MODE  FLOW ON OFF   ALM  Will flash a value if alarmed  LOCK  L
32. sections     The SET button gives access to the thirteen separate screens which  may be used in setting a water treatment program as shown in the  following graphic     SET Menu  Functions        Key pad Function    The convention followed here is  that the    Up  and     Down  arrow keys will cycle first through the screens  and the ENT button will set the cursor position within  the screen  The arrow keys are then able to adjust  those values highlighted by the blinking cursor   Pressing ENT on completion will take the user to the  next function  When the cursor is returned to the top  left corner of the screen the arrow keys can be used  to progress to the next or previous screen     Note  Modes have the following meanings     OFF  Output is SET OFF    FLOW  Output only cycles while FLOW ON    CON  Output cycles continuously    ORP   Oxidation Reduction Potential  Output  only cycles while the ORP output is ON    DUTY  Regulates output capacity    TIM  Output only cycles while the Timer is  ON   TIM FLOW  Output only and cycles when flow is  present    14    Necumecmic vice 2    Set Time and Date Screen   The current time  day  week  and date are important for managing  the treatment program and timing of ORP  biocide control  and for  time stamping the data log  Only two values are adjustable but each  contains several components     CLK denotes clock time in 24 hour format  Hours and minutes are  set separately     DATE denotes the current date  Day  month  and year are 
33. set  separately  This screen also displays the day of the week which  it calculates from the date and the week number according to the  following outline  The week is determined by the controller and  changes at midnight between Saturday and Sunday  Week is used  in the set up of biocide dosing programs     Set Data Logger Screen    This screen is used to set the data logging options  The options are  shown below     Log interval   30 mins   Options  1  2  5  10  15  30  60  120  240  Expressed in minutes    Use the arrow keys to cycle these selections     Log period   is a calculated value that the controller computes and  is expressed in days  The data log file will hold approximately 2400  entries which means that the duration is a function of the log interval   E g  a log interval of 30 minutes will produce a total log period of 35  days     Set Alarms Screen    Allows the user to configure various alarm functions within the  controller     IGNORE FLOW   OFF    When set to ON disables loss of flow alarm   Options  OFF ON   Use arrow keys to cycle these selections     REPEAT   Every Morning    Options  Every Morning Every 4 hrs Once only Never   Use arrow keys to cycle these selections    IGNORE CAL   ON    When set to OFF enables out of calibration    alarms   Options  OFF ON   Use arrow keys to cycle these selections        Note  This option is only available with GSM Modem Option     15    P   System Configuration    SET   value from Table 1   Options  Value range 00 20
34. t from this screen  Table 3              ez c  ix  S T A amp P  Series Series Series Series Series    Acid   Base  The pH controller can be configured to dose acid  A  or  base  B   When configured to A the controller will dose acid  when the pH value rises above the set point  If the controller    is configured to B it will dose alkaline solution to increase  the pH value     MODE   FLOW  Options  FLOW CON OFF  Use arrow keys to  cycle these selections    ALM          Options       alarm if above specified value       alarm if below specified value         alarm if outside specified range    OFF  Alarm disabled  Use arrow keys to cycle these selections   When the cursor is on one of the alarm modes press ENT to change  the numerical values associated with that alarm  Select from the  values of 0 5  1 0  1 5  2 0  3 0  and 3 5  These values are the range  from the set point that will trigger an alarm  Press the ENT again to  move to the next set pH item  A arm defaults  Min  6 5   Max  9 5     The controller will issue alarms when these values are exceeded     LOCK   OFF  Options   Preferred lockout period    Value In the range of 10 to 990 minutes    OFF   disabled Use arrow keys to cycle these selections    If the lockout time is greater than 10 the lockout function is active   The controller will then    lock out    output after the selected time has  elapsed without the controller having reached its nominated set  point for pH  This is a safety feature to prevent overdosa
35. tain the problem     Determine thatthe modem has been setto operate  at 9600 baud  8 bits  1 stop  and no parity     Determine that the modem is initiallising by  observing flashing LEDS on the modem at the  start of the connection     Use HyperTerminal to communicate with an  external PC such as in an IT department or within  Aquarius Technologies     Ascertain if the modem is connected to the site  and the controller is receiving the incoming call  and is auto answering    Supply Aquarius with the site details to ascertain  if a connection can be made from another PC     27    2PAA ESA    BMS 4   20 mA  Interface    Introduction   The Building Management System output option  for your controller provides a local BMS PLC   SCADA system with 4 20 mA signals proportional  to measured values  along with ON OFF  clean  contact relays for Alarm  Flow  and the status of  all output relays     Connections   All connections for BMS outputs are made via  the BMS Connector Board  cabled through spare  glands in the base of the enclosure  The BMS  Connector Board provides clear labelling of all 4   20 mA and relay status outputs  The configuration  of the event outputs is discussed below     4 20 mA Outputs   The BMS output option is available in 4 channel      C    series  or 8 channel configurations  8 channel  KPI only   with 4 20 mA signals proportional to  Temperature  Conductivity  pH and ORP   along  with umPY and PIT rates on two metals for KPI 3  series controllers         4  
36. uperchlorination start   Options Super     24 hr timer  Available Chlorination    Use arrow keys to cycle these Minimum ORP  selections        DUR   0  Maximum ORP   Options   Superchlorination Default Value   duration    Value between 1 and 24 hrs  Superchlorination operates on the next available SET day after the   Use arrow keys to cycle these program has been entered  If Superchlorination is set to operate at   selections  the current date and time it will occur on the next available SET day   INT   0 unless a one week interval is set in which case Superchlorination     0  will begin immediately    Options   Superchlorination   frequency  SET   550    Value in the range of 1 to 12 Options   ORP control point  In the range of 500 to 850 mV    weeks  Use arrow keys to cycle these selections   Use arrow keys to cycle these Warning default  Min 350  Max 850  The controller will issue a   selections  warning when these values are exceeded     19    Pd System Configuration    Set Calcium Hardness Screen    Allows user to enter the calcium hardness of the system water   This value is used in LSI  Langelier Saturation Index  calculations  Also  allows the user to enter Cyanuric Acid level for FAH calculations   Cal H   250    Options  Value in the range of 10 and 500    Use arrow keys to cycle these selections    CYAN   0    Options  Value in the range of 0 to 95    Use arrow keys to cycle these selections     Set Protocol Screen   Allows user to select either of two protocol opt
37. used for communications  and downloads in two modes      Locally   connect the laptop with AquaGuard 2  installed to the DB9 connector on the controller  located internally on PCB  using a serial cable     Remotely   with a GSM modem and SIM data  card installed in the controller   AquaGuard 2  can be used to communicate between a laptop   equipped with a mobile phone and Bluetooth  adaptor  via the GSM network to the controller    See AquaGuard 2 User Manual for full details     Troubleshooting of AquaGuard 2    AquaGuard software has been extensively tested  during both development and site trials  However   the rate at which PC hardware and software is  developing make it impossible to ensure that  AquaGuard will operate in all situations  The  greatest problem facing new installations is to  ensure that the software can be installed and that  correct communications can be made     Problems with Software Installation     If error messages occur while AquaGuard is  being installed  record the details of the error and  details of the PC that AquaGuard is being installed  onto such as speed  RAM size  operating system   Windows 2000 etc   serial devices fitted to the  PC  and free disk space  Relay this information  to Aquarius Technologies and our software team  will endeavour to find a solution     Problems with Communication     If correct communications cannot be established   record any error messages being shown and  perform the following troubleshooting steps to  ascer
38. ution   AS7007   pH 7 buffer solution   AS5250   250 mV ORP solution   AS5475   475 mV ORP solution   AS4250   pH 4 01 250 mV combo solution  AS7086   pH 7 01 86 mV combo solution    Sensors    PR_FCT     Combination Conductivity  Flow and  Temperature Sensor    PR_pHORP   Combination pH  ORP and  Ground reference Sensor    Peristaltic Pumps  AP_PERI_S_KIT     AP PERI SERVICE KIT   Maximum service interval   12 mths     Included in this Kit are the following  e AP_TUBE4824  1       AP_INJECT  1     TUBESUCTION 2     TUBEDISCHARGE  2     AP_PERI_O_KIT     AP PERI OVERHAUL KIT   Maximum service interval   2 years    Included in this Kit are the following   e AP_TUBE4824  1    e AP_INJECT  1    e AP_ROLLBACK  1    e AP_DWEIGHT  1    e AP_LID  1    e TUBESUCTION  2   e TUBEDISCHARGE  2     Test Meters required  HI9813 Portable pH cond meter  HI8314 Portable pH ORP meter    Routine Testing    The use of an Aquarius control system will  automatically vary the dosages and maintain  good conductivity  pH  ORP and disinfection  control  even where there are wide fluctuations  in system load or demand     The principles of    Best Practice    and    Duty of  Care    that are the responsibility of the system  owner dictate that all systems should be  routinely serviced and tested chemically and  the results logged     gf Installation Guidelines    Warnings    Chemicals used as part of the treatment  program may be hazardous  Refer to the  Material Safety Data Sheets  MSDS  provided  by 
39. ve the settings   AT amp W   Program the phone book  AT CPBW 1  0421XXXXXX  129    Berts Mob     AT CPBW 2    0419XXXXXX  129    Freds Mob     AT CPBW 3    0419XXXXXX  129    Toms Ph     Index   s 1 to 10 to be used for alarm messages   You can do things like      List all the phone numbers   AT CPBR 1 10   To send a test sms message  AT CMGS      lt phone number gt     lt enter gt alarm  message here lt CTRL Z gt     SMS call centre number     If your having trouble sending an SMS from the  GSM Modem it may be that the SMS Call Centre  number on the sim card is incorrect  To check  this place the SIM card into a mobile phone then  go into Messages   gt  Message Settings   gt   Message Centre Number  The number here  in Australia should be  61418706700  If not   change the number and save it to the SIM card  before returning it to the GSM Modem     Signal Strength     You can check the signal strength at your  location by entering the AT CSQ command   This can be done with or without the SIM Card  in the Modem  A 0 33 response is OK  If  you get 99 back  there is no Network available     Scumecnie tice 2    Using AquaGuard 2 for remote Communications    Installation    The AquaGuard 2 Software Program CD needs  to be installed on a PC or laptop to be used for  communications and be within its 30 day free  trial period  or the AquaGuard 2 Activation Key  CD must be purchased and installed on the  PC to allow communication with the particular  controller     AquaGuard 2 can be 
40. w   Default Mode       When the cursor is on one of the alarm modes press ENT to change  the numerical values associated with that alarm  Select from the  values of 0 1  0 2  0 4  0 8  1 0  1 5 and 2 0  These values are the  range from the set point that will trigger an alarm  Press the ENT  again to move to the next set conductivity item     LOCK  is not applicable to Conductivity     The controller will alert the user after five minutes if actual value  deviates greatly from the set point value  This aids the prevention  of false alarms     NScumecnicticiicn 2       SET     value from Table 2  Options   Value range of 0 to 999 mV   Use arrow keys to cycle these  selections    DUTY     50     Pump Dose Duty   Options  Values in the range of  1 to 100   Use the arrows to  cycle these selections     MODE   FLOW    Options  FLOW CON TIM   OFF    Use arrow keys to cycle these  selections    ALM          Options       alarm if above specified  value       alarm if below specified  value         alarm if outside specified  range    OFF  Alarm disabled    Use arrow keys to cycle these  selections     Set ORP Screen  Not Available on all Controllers  Refer to table 2  Adjacent   Allows the user to set the ORP options for the controller     Table 2     CT         Models   ORP orl S y AEE              Series Series Series Series Series   Options Oxidising  Availabl  Not   a E Visible   Default Mode ont    Unsafe minimum  ORP warning  Unsafe maximum  ORP warning  Default Values       W
41. when  the Relay Output for the specific function is  activated  eg  pH terminal will go active 240Vac  when the pH monitored value is outside the  set point  These outputs should be wired by  a qualified electrician  The Neutral and Earth  connections for each output must be connected  to the commoning blocks using the terminals     To install    Unpack the equipment and check for any  damage  Ensure all parts are accounted for     Assemble the inlet and outlet PVC valves on  the sensor manifold  Remove the protective cap  and fit the pH ORP probe into the manifold     Connect a 20 mm line from the circulating  pump discharge line  or system common  discharge header  to the inlet of the manifold   Connect a return line from the manifold outlet  valve preferably in PVC pipe to the discharge  side of the filter   see page 9     Install chemical tanks as required  and ensure  each dose pump discharge tubing is connected  to the manifold injection points provided     Run a flow of water through the system under  normal operating pressures  Check for  and  repair any leaks  The Aquarius Controller is  now ready for use  Liaise with your chemical  specialist for advice regarding any bunding  requirements  floor drainage requirements and  fresh water supply in the vicinity of chemical  tanks  In addition check on local authority  regulations for discharge of trade waste   chemical storage and hazards control etc     NOTE   When installing controller units for  CO2 gas   please refer
42. your chemical supplier and ensure personnel  involved are aware of the handling and safety  procedures     Please read and understand all safety warnings  on chemical containers before servicing any  dosing equipment     Wear as a minimum   safety goggles and gloves  when servicing the dosing equipment     Do not mix concentrated acids and oxidising  agents as explosion  and or toxic and lethal  gas may be evolved  and or fire result  Keep  all chemical containers sealed and free from  contamination     Salt water chlorinators draw high currents  when operated  The controller is fitted with a  Normally Open  Normally Closed Relay for  activating the chlorinator  This relay is suitable  to a max  of 10A  Please consult the chlorinator  specs to determine current draw  If greater than  10A  the relay may only be used to activate a  contactor which in turn control the chlorinator      see wiring diagram on page 9   Regular Inspections and Maintenance    For optimum results and continued accuracy     Maintenance  Clean and Calibrate FCT Probe V    1 Month    the complete operation of the controller system  should be verified at least on a monthly basis     All sensors should be inspected  cleaned and  calibrated as necessary every month     The pH ORP sensor age with time and  temperature  and have a typical life span of 2 3  years depending on the application in which  they are operating  They should be replaced  accordingly     Where fitted  flow sensors  solenoid valves and  w
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
(pdf, 0.5mo)  Construcción - Tierra Mia CA  Merlin Stealth M113S User 1.0  Brodit 511414 holder  品種特定キットver2 製品案内 (PDFファイル  取扱説明書  Manual de usuario del sistema de pago y facturación del Sexto Foro  WT-03 取扱説明書ダウンロード(2.3MB  Avaya BCM450 Configuration Guide  "取扱説明書"    Copyright © All rights reserved. 